DEEP SEA ELECTRONICS 890 / 891 GATEWAY INSTALLATION INSTRUCTIONS 053-140 ISSUE 3.1 The Gateway communicates to the connected controller(s) monitoring the instrumentation and operating state. If the data changes, the new data is logged in the Gateway s memory. At regular intervals the logged data is transmitted to the WebNet host server via ethernet (890 / 891) or GPRS 2G/3G (890 only, SIM card not supplied by ). Additionally, 890 contains a GPS location receiver. For more detailed information please refer to the Operating manual and Software manuals listed below. SETUP You may wish to consult your company IT department before making changes to your PC network settings. Connect the Gateway ethernet port directly to your PC Ethernet port. You can use either a straight through or crossover network cable. Set the PC IP address as shown. Using Google Chrome, Microsoft Internet Explorer or Mozilla Firefox, enter the IP address of the gateway. Enter the username and password of the Gateway. NOTE:- Username and Password are both CASE SENSITIVE. For further details refer to the following publications available from our website : www.deepseaplc.com 057-165 890/891 WebNet Gateway Manual 057-168 WebNet Software Manual Factory Settings IP Address Username Password 192.168.1.100 Admin Password1234 Deep Sea Electronics Plc. Tel:+44 (0)1723 890099 Fax: +44 (0)1723 893303 Email: support@deepseaplc.com Web: www.deepseaplc.com Deep Sea Electronics Inc. Tel: +1 (815) 316-8706 Fax: +1 (815) 316-8708 TOLL FREE (USA only) : Telephone: +1 866 636 9703 Email: support@deepseausa.com Web: www.deepseausa.com
LED STATUS DIMENSIONS Overall size Mounting type Din rail type Mounting holes Mounting hole centres Maximum Ambient Operating Temperature 85 mm x 149 mm x 51 mm (3.35 x 5.85 x 2.01 ) DIN rail or chassis mounting Indoor Use Only EN 50022 35mm type only M4 clearance 73 mm x 137 mm (2.89 x 5.39 ) 50ºC (122ºF) TYPICAL WIRING DIAGRAM TO MEET UL APPROVALS, PLEASE USE A UL LISTED LIMITED POWER SUPPLY (8V DC -36V DC) 0.51 Nm (4.5 lb in)
provides a web-based control and monitoring solution for control modules all over the globe. supports single or multi-set systems via a range of devices, which support a suitable internet browser. This includes Laptop / PC, Smart Phone or Tablet devices. On-screen information presents real-time generator and system information in an easy to use format with a flexible means of data transmission through Ethernet or GSM 3G via the device. Location information can be provided by an external GPS antenna connected to the device. Reduced site visits and maintenance costs Fuel management Fault analysis Asset tracking & geofencing Automatic system alerts & reports Maximises system up-time Customisable graphical user interface ADVANCED COMMUNICATIONS SOLUTION
IS THE IDEAL SOLUTION FOR EFFICIENT GENSET MAINTENANCE, FLEET MANAGEMENT, ASSET TRACKING, REMOTE/PERIODIC GENSET TESTING, FUEL MANAGEMENT, FAULT ANALYSIS & MUCH MORE. The system offers features including mapping with real-time location, instrumentation and control, event log tables and automatic system alerts which can be sent to multiple users via email and SMS. The device provides the user with full and instant access to the system. A single Gateway device can be connected to a maximum of five supported controllers. This creates a vast and extensively featured remote control and monitoring solution. Comprehensive on-screen information is presented in clear, graphical and numerical formats which are easy to navigate and operate. can be utilised to maximise system up-time by offering the most effective remote management tool. An unlimited number of users can access a single Gateway device. Additionally a single user can access up to fifty Gateway devices. To gain access to either the Gateway device or, secure login information is required. This low cost solution makes the system a secure and effective remote control and monitoring solution for multiple users and sites.
MULTIPLE AND CONFIGURABLE SCREENS ARE AVAILABLE TO SHOW A COMPREHENSIVE LIST OF ENGINE, GENERATOR, MAINS AND SYSTEM INFORMATION. REQUIRES ONE OR MORE DEVICES CONNECTED TO SUPPORTED CONTROLLERS TO UTILISE ALL OF THE AVAILABLE FEATURES. 1. 2. 3. 4. 5. 6. Global mapping shows multiple site locations Aerial view of a single site location with multiple generators Multiple or single site generator event recording & monitoring Engine monitoring Generator & mains monitoring controller input & output state diagnostics
WebNet SMART DEVICE APPLICATION ADVANCED COMMUNICATIONS SOLUTION WEB BASED CONTROL AND MONITORING SOLUTION FOR CONTROL MODULES, NOW AVAILABLE IN A SMART DEVICE APPLICATION. The WebNet Mobile Application is designed to give the ultimate remote access to your genset system for busy engineers on the move this is a must have tool! Designed for use on smart phones and tablet devices, the software has a fast response time so that you are able to monitor and control your control module, anywhere in the world. You are able to view and control all modules that are connected to your WebNet account. Realtime instrumentation, alarms, notifications, input & output status and historic data graphs, provide the highest degree of engineering/maintenance flexibility. Available for Apple and Android Platforms, please use the relevent QR code to go directly to the App Store. Available as a smart device webpage for all other platforms. Apple ios DEEP SEA ELECTRONICS PLC UK Highfield House, Hunmanby Industrial Estate, Hunmanby YO14 0PH TELEPHONE +44 (0) 1723 890099 FACSIMILE +44 (0) 1723 893303 EMAIL sales@deepseaplc.com WEBSITE www.deepseaplc.com Android DEEP SEA ELECTRONICS INC USA 3230 Williams Avenue, Rockford, IL 61101-2668 USA TELEPHONE +1 (815) 316 8706 FACSIMILE +1 (815) 316 8708 EMAIL sales@deepseausa.com WEBSITE www.deepseausa.com Deep Sea Electronics Plc maintains a policy of continuous development and reserves the right to change the details shown on this data sheet without prior notice. The contents are intended for guidance only. Registered in England & Wales No.01319649 VAT No.316923457 055-192/08/14 (1) US
COMMUNICATIONS INTERFACE The is used in conjunction with supported controllers to provide monitoring and communications data via the advanced communications system. The communicates to a maximum of five connected controller(s), monitoring the instrumentation and operating state. When this data changes, the new data is logged in the internal memory. At regular intervals the logged data is transmitted to the hosted server. The hosted server is then integrated into the which can be accessed via an internet connected device and web browser to allow remote monitoring and control of multiple controllers worldwide. GSM, GPS and combined GSM & GPS antenna s are available as accessories. 890 WebNet Gateway - 3G (GSM) & Ethernet The Gateway connects to the data server by integral Ethernet connection or GPRS (GSM or 3G mobile internet) and includes GPS (satellite location) functionality. This is most suited to remote and/or mobile locations. 891 WebNet Gateway - Ethernet Only The Gateway connects to the data server by an integral Ethernet connection only. This is most suited for fixed installations where an ADSL or DSL cable broadband service is available (external broadband modem required, not supplied by ). SPECIFICATION DC SUPPLY CONTINUOUS VOLTAGE RATING 8 V to 35 V continuous CRANKING DROPOUTS Able to survive 0 V for 50 ms, providing supply was at least 10 V before dropout and supply recovers to 5 V. This is achieved without the need for internal batteries MAXIMUM OPERATING CURRENT GSM 700 ma at 12 V 450 ma at 24 V GSM & GPS 700 ma at 12 V 450 ma at 24 V Ethernet 200 ma at 12 V 110 ma at 24 V Ethernet & GPS 700 ma at 12 V 450 ma at 24 V MAXIMUM STANDBY CURRENT GSM 270 ma at 12 V 150 ma at 24 V GSM & GPS 270 ma at 12 V 150 ma at 24 V Ethernet 150 ma at 12 V 90 ma at 24 V Ethernet & GPS 270 ma at 12 V 150 ma at 24 V COMMUNICATIONS USB (Single Controller) RS232 (Single Controller) RS485 (Multiple Controllers) Ethernet (Multiple Controllers) DIMENSIONS 85 mm x 149 mm x 51 mm ENVIRONMENTAL TESTING STANDARDS ELECTRO-MAGNETIC COMPATIBILITY BS EN 61000-6-2 EMC Generic Immunity Standard for the Industrial Environment BS EN 61000-6-4 EMC Generic Emission Standard for the Industrial Environment ELECTRICAL SAFETY BS EN 60950 Safety of Information Technology Equipment, including Electrical Business Equipment TEMPERATURE BS EN 60068-2-1 Ab/Ae Cold Test -30 o C BS EN 60068-2-2 Bb/Be Dry Heat +70 o C VIBRATION BS EN 60068-2-6 Ten sweeps in each of three major axes 5 Hz to 8 Hz at +/-7.5 mm, 8 Hz to 500 Hz at 2 gn HUMIDITY BS EN 60068-2-30 Db Damp Heat Cyclic 20/55 o C at 95% RH 48 Hours BS EN 60068-2-78 Cab Damp Heat Static 40 o C at 93% RH 48 Hours SHOCK BS EN 60068-2-27 Three shocks in each of three major axes 15 gn in 11 ms RELATED MATERIALS TITLE 890 & 891 Installation Instructions 890 & 891 Hardware Manual Data Sheet PC Internet Browser Software Manual Smart Device Software Manual ACCESSORIES PART GSM Antenna GPS Antenna Combined GSM & GPS Antenna PART NO S 053-140 057-165 055-192 057-168 057-235 PART NO S 020-141 020-130 020-150 COMPATIBLE CONTROLLERS INCLUDE: AUTO START MODULES 4310 4410 4510 4610 6010 6010 MKII 6110 6610 ATS MODULES 333 334 335 7110 7110 MKII 7210 7310 7410 8610 8710 8810 8660 8760 8860 AUTO MAINS FAILURE MODULES 4320 4420 4520 4620 6020 6020 MKII 6120 LIGHTING TOWER MODULES L400 L401 6620 7120 7120 MKII 7220 7320 7420 8620 DEEP SEA ELECTRONICS PLC UK Highfield House, Hunmanby Industrial Estate, Hunmanby YO14 0PH TELEPHONE +44 (0) 1723 890099 FACSIMILE +44 (0) 1723 893303 EMAIL sales@deepseaplc.com WEBSITE www.deepseaplc.com DEEP SEA ELECTRONICS INC USA 3230 Williams Avenue, Rockford, IL 61101-2668 USA TELEPHONE +1 (815) 316 8706 FACSIMILE +1 (815) 316 8708 EMAIL sales@deepseausa.com WEBSITE www.deepseausa.com Deep Sea Electronics Plc maintains a policy of continuous development and reserves the right to change the details shown on this data sheet without prior notice. The contents are intended for guidance only. Registered in England & Wales No.01319649 VAT No.316923457 055-117/02/12 (2) US
IS THE IDEAL SOLUTION FOR EFFICIENT GENSET MAINTENANCE, FLEET MANAGEMENT, ASSET TRACKING, REMOTE/PERIODIC GENSET TESTING, FUEL MANAGEMENT, FAULT ANALYSIS & MUCH MORE. The system offers features including mapping with real-time location, instrumentation and control, event log tables and automatic system alerts which can be sent to multiple users via email and SMS. Comprehensive on-screen information is presented in clear, graphical and numerical formats which are easy to navigate and operate. can be utilised to maximise system up-time by offering the most effective remote management tool. The device provides the user with full and instant access to the system. A single Gateway device can be connected to a maximum of five supported controllers. This creates a vast and extensively featured remote control and monitoring solution. An unlimited number of users can access a single Gateway device. Additionally a single user can access up to fifty Gateway devices. To gain access to either the Gateway device or, secure login information is required. This low cost solution makes the system a secure and effective remote control and monitoring solution for multiple users and sites.