Magnetic field sensor Magnetic-inductive Proximity Sensor BIM-M12E-Y1X

Similar documents
Magnetic Field Sensor Magnetic-inductive Proximity Sensor BIM-EG08-Y1X

Magnetic Field Sensor Magnetic-inductive Proximity Sensor BIM-M12E-Y1X-H1141

Magnetic Field Sensor Magnetic-inductive Proximity Sensor BIM-EG08-Y1X-H1341

Inductive sensor BI5-EM18-Y1X-H1141

Inductive sensor BI1.5-EG08-Y1-H1341

Inductive sensor NI3-EG08K-Y1-H1341

Inductive sensor BI1.5-EG08-Y1-H1341

Inductive sensor Dual sensors with extended temperature range NI4-DSU35TC-2Y1X2/S97

Inductive dual sensor For rotary actuators NI4-DSU35TC-2Y1X2/S933

Inductive sensor For rotary actuators NI4-DSU35TC-2Y1X2

Magnetic Field Sensor for pneumatic cylinders BIM-INT-Y1X-H1141

Inductive sensor For rotary actuators NI4-DSU35TC-2Y1X2/S933

Inductive sensor For rotary actuators NI4-DSU35-2Y1X2-H1140

Inductive sensor with analog output BI15-M30-LI-EXI

Inductive angle sensor with analog output Ri360P1-DSU35TC-ELi-Exi

Inductive Angle Sensor With Analog Output RI360P1-DSU35TC-ELI-EXI

Signal processor MS96 for flow sensors MS96-11EX0-R/230VAC

Operating instructions (Safety-related part ATEX and IECEx) Inductive NAMUR sensors NN504A NN505A NN506A NN507A /00 08/2015

Technical Data. General specifications. Rated operating distance s n 3 mm

Technical Data. General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm. Short-circuit protection

PHOENIX CONTACT - 12/2007

Diffuse reflection light scanner with background suppression. Dimensioned drawing

NAMUR INDUCTIVE SENSOR ATEX/IECEx

VM series. features. web contents. code description. available models. inductive sensors. Cylindrical M12 in AC B H

Thread length (overall length) material

Pneumatic Control/Feedback

PI-EX-ME-2NAM/COC-24VDC

Pneumatic Control/Feedback

Pneumatic Control/Feedback

PI-EX-ME-2NAM/COC-120VAC

Flow monitoring For the connection of intrinsically safe flow sensors IO-Link device with relay outputs FMX-IM-3UR38X

Digital Output Module 8-Channel Version for Zone 1 Series 9475/

4 Remote I/O. Digital Output Module 8-Channel Version Type 9475/ from Rev. F

TURCK Process Automation IS Interface Technology. Interface Modules. IM Series Cabinet

E2A. Ordering Information. Cylindrical Proximity Sensor. Safe Mounting with Greater Sensing Distance. E2A Cylindrical Proximity Sensor 1

Assembly. Front view. LED yellow: Relay output. LED red: LB/SC Power Rail

Thread length. 27 (40) mm. 27 (44) mm. 27 (40) mm. 34 (50) mm. 34 (49) mm. 39 (60) mm. 39 (54) mm. 44 (65) mm. 44 (59) mm

TFR5. Room or outdoor temperature sensor. Operating instructions for temperature sensor. English page 1...5

Sensors with analog output

BL compact fieldbus station for DeviceNet 16 Configurable Digital PNP Channels BLCDN-16M8L-8XSG-P-8XSG-P

BL compact fieldbus station for DeviceNet 16 Configurable Digital PNP Channels BLCDN-8M12LT-8XSG-PD-8XSG-PD

DMP 333 DMP 333. Industrial Pressure Transmitter For High Pressure. Stainless Steel Sensor. Pressure Transmitter. Industrial

Digital Output Module 8-Channel Version for Zone 2 Series 9475/

Digital Output Module 4-Channel Version for Zone 1 Series 9475/

Inductive proximity switches with long operating distance, series 500

Installation Sensing distance Connection Output configuration Operation mode NO Operation mode NC

ADAMCZEWSKI. Ordering data AD-STVEX 710 GVD Option: Factory-software configuration as per customer specifications.

Rotary Measurement Technology Absolute Encoders, Singleturn

Compact Inductive Proximity Sensor

Digital Output Module 4-Channel Version for Zone 1 Series 9475/

Rotary Measurement Technology Absolute Encoders, Multiturn

Safety coded magnetic sensor SR A series

Original operating instructions Fail-safe inductive sensor GF711S / / 2013

Sensor boxes SRBC. Festo core product range Covers 80% of your automation tasks

APPLICATION GUIDE. Interface Modules IM Series.

ExBin-D Transducers for ExPro-B... sensors (probes) ExPro-B... Thermostats / humidistats ( C, % rh)

standard, short, preferential, top

Float Switches with Permanent Magnet For Vertical Installation Model RSM

PHOENIX CONTACT - 01/2008

PHOENIX CONTACT - 05/2007

AK series M18 cylindrical inductive sensors

Operating instructions

Digital Output Module 8-Channel Version for Zone 2 Series 9475/

LMP 308. Separable Stainless Steel Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO / 0.

PFK series M18 cylindrical inductive sensors

GX SERIES. Cylindrical Compact Inductive Proximity Sensor Amplifier Built-in. Robust enclosure and flexible cable types are also available

MACX MCR-EX-SD LP(-SP)

Inductive proximity sensors Cylindrical threaded housing, IM12 NAMUR

5 Fieldbus Technology

Threaded resistance thermometer Miniature design Model TR10-D

Original operating instructions Fail-safe inductive sensor GI711S / / 2010

Sensor boxes SRBG Key features

CODESYS 3 Programmable Gateway for the BL20 I/O System Multiprotocol Ethernet Gateway for PROFINET, EtherNet/IP and Modbus TCP BL20-PG-EN-V3

Rotary Measurement Technology Absolute Encoders, Singleturn

Your Global Automation Partner. Inductive Sensors uprox with IO-Link Interface. Operating Instructions

Material pressure (bar) (Cv (US) kv x 1,2 Seat

BL compact fieldbus station for DeviceNet 4 Analog Inputs for Current or Voltage and 8 Configurable Digital PNP Channels BLCDN-8M12L-4AI-VI-8XSG-PD

Series 3730 Electropneumatic Positioner Type

SR A series coded magnetic safety sensor

D6030S - D6030D INSTRUCTION MANUAL. D SIL 3 Switch/Proximity Detector Repeater Relay Output. Models D6030S, D6030D

Threaded thermocouple Miniature design Model TC10-D

Power supply. Interface technology in modular housing DIN rail devices, IM series. Features

4 non-safe digital I/O channels 2 IO-Link Master V1.1 slots. Figure 1. Figure 2. Type designation. TBPN-L1-FDIO1-2IOL Ident-No

KINAX WT720 absolute, programmable angular postion transmitter

Series 3730 Type Electropneumatic Positioner

Operating Instructions. Intrinsically Safe Isolation Relay for Switches Model: REL manual_rel-6_0505

GA-311 GH SERIES. Compact Inductive Proximity Sensor Amplifier-separated. High-speed response and excellent workability

Compact multiprotocol I/O module for Ethernet 16 digital outputs 2 A FGEN-OM

Digital Positioner 8049

PHOENIX CONTACT - 02/2008

GA-311 GH SERIES. Compact Inductive Proximity Sensor Amplifier-separated. High-speed response and excellent workability. IP67G sensor head variations

SR B series coded magnetic safety sensors

Assembly. Front view. LED yellow/red: Status output Ι/ Fault signal Function. Switch Power Rail

Ferrous metal (The sensing distance decreases with non-ferrous metal.) Power supply voltage (operating voltage range)

Operating Manual / IEC. Explosion-Proofed Junction Boxes, Polyester. Wallücker Bahndamm 7 DE Kirchlengern

Ex magnetic safety sensors, cylindrical form // Series EEx RC Si M30

MINI MCR-SL-RPS-I-I. Repeater power supply, active. Data sheet. 1 Description

BL compact multiprotocol fieldbus station for Industrial Ethernet 8 Analog Inputs for Current or Voltage BLCEN-8M12LT-4AI-VI-4AI-VI

ExCos-P Pressure sensor 20 Pa Pa

PHOENIX CONTACT Pin. SUBCON-PLUS M ARCNET, MULTI/MININET (B&R), SYSTEM 2003 (B&R), P-NET SUCONET K1, K2 (EATON/Moeller),

Transcription:

ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 as per IEC 61508 Threaded barrel, M12 x 1 Chrome-plated brass Rated operating distance 90 mm with DMR31-15-5 magnet DC 2-wire, nom. 8.2 VDC Output acc. to DIN EN 60947-5-6 (NA- MUR) Cable connection Wiring Diagram Type designation Ident-No. 1074002 Ident-No (TUSA) M1074002 Rated switching distance Sn 90 mm In conjunction with magnet DMR31-15-5 Repeat accuracy ð 0.3 % of full scale Temperature drift ð ± 15 % Hysteresis 1 10 % Ambient temperature -25 +70 C Output function Switching frequency Voltage Current consumption non-actuated Actuated current consumption Approval acc. to 2-wire, NAMUR 1 khz Nom. 8.2 VDC ð 1.2 ma ï 2.1 ma KEMA 02 ATEX 1090X Design Threaded barrel, M12 1 Dimensions 64 mm Housing material Metal, CuZn, Chrome-plated Active area material Plastic, PBT-GF30 End cap Plastic, EPTR Max. tightening torque housing nut 10 Nm Electrical connection Cable Cable quality 5.2mm, Blue, LifYY, PVC, 2 Cable cross section 2 x 0.34 mm 2 Vibration resistance 55 Hz (1 mm) Shock resistance 30 g (11 ms) Protection class IP67 MTTF 6198 years acc. to SN 29500 (Ed. 99) 40 C Functional principle Magnetic inductive proximity sensors are actuated by magnetic fields and are thus capable of detecting permanent magnets through non-ferromagnetic materials (e.g. wood, plastic, non-ferrous metals, aluminium, stainless steel). Thus it is possible to achieve large switching distances even with smaller housing styles. In combination with the actuation magnet DMR31-15-5 TURCK sensors feature a relatively high switching distance. Thus there are multiple detection possibilities, particularly if the mounting space is limited or other difficult sensing conditions prevail. Switching state LED yellow 1 / 5 TURCK Inc. ñ 3000 Campus Drive Minneapolis, MN 55441-2656 ñ Phone: 763-553-7300 ñ Application Support: 1-800-544-7769 ñ Fax 763-553-0708 ñ www.turck.com

Diameter active area B Ø 12 mm 2 / 5 TURCK Inc. ñ 3000 Campus Drive Minneapolis, MN 55441-2656 ñ Phone: 763-553-7300 ñ Application Support: 1-800-544-7769 ñ Fax 763-553-0708 ñ www.turck.com

Accessories Type code Ident-No. Description IMX12-DI01-2S-2T-0/ 24VDC 7580020 Isolating switching amplifier, 2-channel; SIL2 acc. to IEC 61508; Ex-proof version; 2 transistor outputs; input Namur signal; ON/OFF switchable monitoring of wire-break and short-circuit; toggle between NO/NC mode; signal doubling; removable screw terminals; 12.5 mm wide; 24 VDC power supply DMR20-10-4 6900214 Actuation magnet; Ø 20 mm (Ø 4 mm), h: 10 mm; sensing range 59 mm on BIM-(E)M12 sensors resp. 50 mm on BIM- distance between sensor and magnet: 3 4 mm DMR31-15-5 6900215 Actuation magnet, Ø 31 mm (Ø 5 mm), h: 15 mm; sensing range 90 mm on BIM-(E)M12 sensors resp. 78 mm on BIM- distance between sensor and magnet: 3 5 mm DMR15-6-3 6900216 Actuation magnet, Ø 15 mm (Ø 3 mm), h: 6 mm; sensing range 36 mm on BIM-(E)M12 sensors resp. 32 mm on BIM- distance between sensor and magnet: 3 4 mm DM-Q12 6900367 Actuation magnet; rectangular, plastic; attainable switching distance 58 mm on BIM-(E)M12 sensors resp. 49 mm on BIM-EG08 sensors; in combination with Q25L linear position sensors: recommended distance between the sensor and magnet: 3 5 mm 3 / 5 TURCK Inc. ñ 3000 Campus Drive Minneapolis, MN 55441-2656 ñ Phone: 763-553-7300 ñ Application Support: 1-800-544-7769 ñ Fax 763-553-0708 ñ www.turck.com

Accessories Type code Ident-No. Description BSS-12 6901321 Mounting bracket for smooth and threaded barrel devices; material: Polypropylene MW-12 6945003 Mounting bracket for threaded barrel devices; material: Stainless steel A2 1.4301 (AISI 304) 4 / 5 TURCK Inc. ñ 3000 Campus Drive Minneapolis, MN 55441-2656 ñ Phone: 763-553-7300 ñ Application Support: 1-800-544-7769 ñ Fax 763-553-0708 ñ www.turck.com

Operating manual Intended use This device fulfills the directive 2014/34/EC and is suited for use in explosion hazardous areas according to EN 60079-0:2012 + A11 and EN 60079-11:2012. Further it is suited for use in safety-related systems, including SIL2 as per IEC 61508. In order to ensure correct operation to the intended purpose it is required to observe the national regulations and directives. For use in explosion hazardous areas conform to classification II 1 G and II 1 D (Group II, Category 1 G, electrical equipment for gaseous atmospheres and category 1 D, electrical equipment for dust atmospheres). Marking (see device or technical data sheet) É II 1 G and Ex ia IIC T6 Ga acc. to EN60079-0 and -26 and É II 1 D Ex ia IIIC T115 C Da acc. to EN60079-0 Local admissible ambient temperature -25 +70 C Installation / Commissioning These devices may only be installed, connected and operated by trained and qualified staff. Qualified staff must have knowledge of protection classes, directives and regulations concerning electrical equipment designed for use in explosion hazardous areas. Please verify that the classification and the marking on the device comply with the actual application conditions. This device is only suited for connection to approved Exi circuits according to EN 60079-0 and EN 60079-11. Please observe the maximum admissible electrical values. After connection to other circuits the sensor may no longer be used in Exi installations. When interconnected to (associated) electrical equipment, it is required to perform the "Proof of intrinsic safety" (EN60079-14). Attention! When used in safety systems, all content of the security manual must be observed. Installation and mounting instructions Avoid static charging of cables and plastic devices. Please only clean the device with a damp cloth. Do not install the device in a dust flow and avoid build-up of dust deposits on the device. If the devices and the cable could be subject to mechanical damage, they must be protected accordingly. They must also be shielded against strong electro-magnetic fields. The pin configuration and the electrical specifications can be taken from the device marking or the technical data sheet. service / maintenance Repairs are not possible. The approval expires if the device is repaired or modified by a person other than the manufacturer. The most important data from the approval are listed. 5 / 5 TURCK Inc. ñ 3000 Campus Drive Minneapolis, MN 55441-2656 ñ Phone: 763-553-7300 ñ Application Support: 1-800-544-7769 ñ Fax 763-553-0708 ñ www.turck.com