Peak/Valley Hold Unit (PVHU) User Manual V3.00

Similar documents
Eco Line Signal Converters User Manual

20.4VDC to 28.8VDC with less than 10% ripple. Input impedance 10mSec typical, when used as normal digital inputs

Model SC500. Programmable Single-Channel Transducer Indicator/Conditioner DESCRIPTION FEATURES

Universal counter UZ 9648 Counting - length measurement - metering - positioning

V E1B Snap-in I/O Module

MP-2000 Dual Channel LVDT/RVDT Readout/Controller

Power Supply Input voltage 20.4VDC to 28.8VDC with less than 10% ripple Max. current consumption See Note 1

V E2B Snap-in I/O Module

The PM1000 series is a universal 4 digit LED plug-on display for transmitters with 4-20mA 2 wire output and fitted with DIN43650 connector.

Samba PLC+HMI SM35-J-RA22

MYRIAD QLC 4-CHANNEL MONITOR/CONTROLLER INSTRUCTION MANUAL

3 Digital, 3 Digital/Analog, 3 PT1000/NI1000 Inputs, 5 Relay, 1 pnp/npn Outputs

Displays Transducers. Displays and transducers

LAUREL ELECTRONICS, INC.

T600 TACHOMETER MultiTasker - a measurement & monitoring instrument with 2 frequency and 1 analog inputs

Isolated Voltage Input 7B31 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Item SM35-J-TA22 SM43-J-TA22 SM70-J-TA22

LAUREL. Laureate Pulse or Analog Input Batch Controller Automatic batch control for repetitive liquid fill operations ELECTRONICS, INC.

Power Supply Input voltage 20.4VDC to 28.8VDC with less than 10% ripple Max. current consumption See Note 1

LAUREL ELECTRONICS, INC.

FEATURES DESCRIPTION FEATURES

5450 NW 33rd Ave, Suite 104 Fort Lauderdale, FL Fruitland Ave Los Angeles, CA SST7000 SST7100. Speed Switch / Transmitter

ECT Signal Isolator/Converter

KTA-250 Anemometer Alarm Card

Isolated, Voltage or Current Input 7B30 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

LCI User Manual mantracourt.com

Isolated Process Current Input with Loop Power 7B35

All Analog Outputs, voltage/current 10mA 35mA 5mA 48mA/30mA* *If the analog outputs are not configured, then subtract the higher value.

MODEL AAMA - UNIVERSAL SIGNAL CONDITIONING MODULE

Isolated Process Current Input 7B32 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Dual Channel Monitor for Measurement of Speed and Ratio with SIL1 requirements Series D224.xx

LE ELECTRONICS Pvt. Ltd.

Isolated, Process Current Output 7B39 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Standard Options. Model 4100 Position Indicating Meter. Three Phase Motor Control. Positran Transmitter

Power Supply Input voltage 20.4VDC to 28.8VDC with less than 10% ripple Max. current consumption See Note 1

UniStream Uni-I/O Modules

Isolated Current Output 5B39 FEATURES APPLICATIONS PRODUCT OVERVIEW

Power Supply Input voltage 20.4VDC to 28.8VDC with less than 10% ripple Max. current consumption See Note 1

MODEL: M5DY SEN TRONIC AG CURRENT LOOP SUPPLY. [2] POWER INPUT AC Power M: V AC (Operational voltage range V, Hz)

Product Specification. tsense VAV. CO 2 -, Temperature- and RH- sensor in a housing with colour touch display

MYRIAD LC1 LEVEL CONTROLLER INSTRUCTION MANUAL

CANBUS Connector Rx and Tx LED to indicate that communication is active Closed circuit terminal (Term) LAN serial port connector

LAUREL. Laureate RTD Temperature Panel Meter / Controller ELECTRONICS, INC. Features. Description. Specifications

Isolated Wideband Voltage Input 3B40 / 3B41 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

ACOPOSinverter P74. User's Manual. Version: 2.20 (August 2016) Model no.: Original instruction

Wide Bandwidth Strain Gage Input 3B18 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

V E6B Snap-in I/O Module

APPLICATION GUIDE. Interface Modules IM Series.

TURCK Process Automation IS Interface Technology. Interface Modules. IM Series Cabinet

HIT/HIX HART Isolator

Controller module. Brief description. Features. Block structure. Data Sheet Page 1/7

V E1B Snap-in I/O Module

V E3XBW Snap-in I/O Module

UNIVERSAL CURRENT CONVERTER

SLIMCON-6 24V DC POWERED ISOLATING SIGNAL CONVERTER

Data Sheet T 6493 EN. TROVIS 6400 Automation System TROVIS 6493 Compact Controller. For panel mounting (front frame 48 x 96 mm/1.89 x 3.

SSR - Supplies - Relays

MODULES FOR SAFETY AND MONITORING

USER INSTRUCTION MANUAL FOR LOADCELL TRANSMITTER MODEL TDC/I/0550 (SOFTWARE: VER2A) INDEX

User safety and equipment protection guidelines

1/32-DIN TEMPERATURE CONTROLLER INSTALLATION, WIRING AND OPERATION MANUAL FORM 3882

POSITION MONITOR USERS MANUAL POM-M2 / POM-M3. Content

Isolated Voltage Input 3B30 / 3B31 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

MICRO SERIES PROCESS DISPLAYS LARGE DIGIT MODELS

T4HD: Installation Supplement R8.1.13

G3PC. Model Number Structure. Solid State Relays with Failure Detection Function. Model Number Legend

Vision OPLC. V TR6 Technical Specifications. Technical Specifications.

The IQ300 wall mount load cell indicator is a precision digital indicator for load cell and strain gauge applications.

G3FM. Model Number Structure. Ordering Information. Solid State Relays. Model Number Legend. List of Models

Amplifiers, Counters, Timers & Controls

The IQ240 panel mount load cell indicator is a precision digital indicator for load cell and strain gauge applications.

Y800 Plus Frequency, Rate & Period Meter With dual, independently field-scalable channels

9000C INDEX APPLICATION EXAMPLE 1 SPECIFICATION 2 SAFETY AND WARNING... 3 CONNECTION 3 INSTALLATION.. 4 ORDERING CODE 4 TROUBLE SHOOTING 4

PGR-6100 MANUAL GROUND-FAULT & INSULATION MONITOR

VariTrans P The Problem The variety of tasks results in a large number of different devices.

SINGLE-CHANNEL PROCESS CONTROLLERS & TEMP. DISPLAYS D3820/D3830 Series

LAUREL. Laureate Digital Panel Meter for Process and Ratiometric Signals ELECTRONICS, INC. Features. Description

Relay Deck Datasheet

PCD3.C90. Date Modification Asked by: Version E/A Bus Connector PCD2.K106 change to PCD3.K106 Müller.R 1.1

SX90 Process Controller

AirTest Model CN9000 Series Sensor Controller

Analog output 520AOD01 Data sheet

LCI Load Cell Junction Box with Fault Monitor

Controller module. Brief description. Features. Block structure. Page 1/7. Data Sheet

20.4VDC to 28.8VDC with less than 10% ripple Max. current consumption See Note 1 npn inputs

MSR Level Control Relay Module Operating Instructions for Level Control Relay Module Model: MSR

Installation & Operation Guide

Dual Channel LVDT/RVDT Readout/Controller

Article no. BWU2045: AS-i Safety Relay Output Module with Diagnostic Slave and 1 EDM Input 1.23 NC

AS-i Safety Relay Output Module with Diagnostic Slave and 1 EDM Input

Signal Doublers. VariTrans A 20300

INDEX INDEX AT A GLANCE AVAILABLE MODELS TECNICHAL FEATURES COMMAND AND CONNECTION DESCRIPTION...

I-7520: RS-232 to RS-485. Input: RS-232 protocol Output:RS-485/RS-422 Speed: Self Tuner 'inside, auto switching baud rate, 300~ BPS

SGJ Cable Actuated Sensor Industrial CANBus J1939

Issue 03/2013. The Electronic Load

Panel Indicators. NEW 4~20mA Panel Display. Process Indicators INTECH INSTRUMENTS.

DCA - 10 / DCA TTS Systems

Model Number Structure

M-series Intrinsically Safe I/O

CheckSum. FUNC-2B Functional Test Module. The FUNC-2B features:

Transcription:

Peak/Valley Hold Unit (PVHU) User Manual V3.00

Part Number: DO-UM0084/30/UE Applies to Firmware Version: V3.01 Reference: Peak_Valley Hold Unit (PVHU) User Manual.docx Date: 30 May 2016 Version: 3.00 Peak/Valley Hold Unit (PVHU) User Manual Contents General Description... 3 Applications... 3 Functional Diagram... 4 Example Operation... 4 Typical Operation... 5 Application Example... 6 Oscilloscope Pictures... 7 Connections... 8 DIP SW1 Run/Operational Settings... 9 Configuration Mode... 10 Resetting to Factory Defaults... 11 Trimming of Outputs - Zero and Span Adjustment... 11 Input Range Selection... 11 Output Range Selection... 12 Analogue Input Setup... 12 Input LED Setup... 12 Analogue Output Setup... 12 Digital Output Setup... 12 Specifications... 13 User Manual... 14 danntech PROCESS INSTRUMENTATION 2016 Page 2 of 14

General Description The Peak/Valley Hold Unit (PVHU) has been designed to provide a way of capturing fast, random or transient events for process measurement and control. Usually only high speed and expensive process systems or PLCs are able to monitor and capture these inputs. The PVHU has one input and two outputs which can be used to capture the maximum (peak) and minimum (valley) values of the input signal. The PVHU captures the maximum and minimum values and holds these values until either another maximum or minimum value is detected, or the RESET TIME expires. The Reset Time can be adjusted from 0% to 100% (using a trimpot) in three ranges: 4 to 100 ms, 4 to 1000 ms and 4 ms to 10 S. There is an additional option to hold the peak and valley outputs until an external digital input resets the captured values. The PVHU has four way galvanic isolation of 1000 VDC between the Power In, the input and each output. The outputs are isolated from each other. A variety of standard signal inputs and outputs can be accommodated: Current (DC): 4-20 ma, 0-20 ma, (factory installed options are 0-1 A, 0-5 A and 0-10 A). Loop power available at +15 V, 22 ma for loop powered transmitter inputs. Voltage (DC): 0-100 mv, 0-1 V, 0-2 V, 0-10 V, 0-30 V, 0-100 V and ±10 V. Resistance: 0-100 Ω, 0-1 kω, 0-10 kω. There is also an option to be able provide 15 V at 30 ma to supply power for a loop powered input sensor or transmitter. The outputs can be different from each other and also different to the input, so the unit can effectively perform signal conversion and isolation functions as well. Special input and output ranges can be provided by arrangement. The unit has two analogue outputs with various options: Current (DC): 4-20 ma, 0-20 ma. Voltage (DC): 0-100 mv, 0-1 V, 0-10 V, ±10 V. As well as some digital I/O options: Relay Outputs - optional: Two alarm relay outputs 30 VDC at 1 A / 125 VAC, 0.3 A. Digital Outputs - optional: Two opto-isolated transistor outputs up to 50 V at 40 ma maximum. Digital Inputs - optional: Two opto-isolated digital inputs 30 V maximum at 5 ma. Applications Fast pulse stretching so that transient events can be captured by standard (slower) controllers or PLCs. Accelerometer peak level capture for machine condition monitoring. Hydroelectric turbine generator pole temperature estimation (see application note). Monitoring of rotor alignment in rotating machines using valley detection. danntech PROCESS INSTRUMENTATION 2016 Page 3 of 14

Functional Diagram Example Operation These oscilloscope traces show the input signal in yellow with the Peak Output in blue and the Valley output in purple. This shown is an example of the outputs one can expect for a fairly high frequency input signal with a fairly short reset time, in this case approximately 20 ms. danntech PROCESS INSTRUMENTATION 2016 Page 4 of 14

Typical Operation danntech PROCESS INSTRUMENTATION 2016 Page 5 of 14

Application Example Simulated input signal constructed from data captured on site by the customer and sent to us for testing. Yellow trace is the simulated input signal, the blue trace is the Peak Output and the purple trace is the Valley Output. The Reset Time in this example is about 20 ms. The same results as above with the traces separated to show more detail. danntech PROCESS INSTRUMENTATION 2016 Page 6 of 14

Oscilloscope Pictures Capturing a single pulse which is 200 µs duration. Peak and Valley Outputs for sine wave input. Repetitive peak and valley capturing. danntech PROCESS INSTRUMENTATION 2016 Page 7 of 14

Connections More information to follow. danntech PROCESS INSTRUMENTATION 2016 Page 8 of 14

DIP SW1 Run/Operational Settings Table 1 Dip Switch SW1 Settings in Run Mode coloured background indicates settings as shipped. SW1 1 2 3 Description Zero, Span and Reset Time Trimpots Enable Enables the operation of the trimpots on the front panel. You can enable the trimpots, make your adjustments and then when you disable the trimpots, the values that you last adjusted are saved and used until the trimpots are enabled again. OFF = trimpots disabled ON = trimpots enabled Zero and Span Normal/Wide Range Adjustment Select Provides normal and wide trimpot adjustments for Zero and Span. OFF = Zero and Span adjustment are normal i.e. approx ±10% over full trimpot range. ON = Zero and Span adjustment are wide i.e. approx ±50% over trimpot range. Note that you may need to adjust zero and span several times to get the best accuracy. Filtering Select Selects the moving average input filter length: Input Step Response SW1-3 SW1-4 Time No filtering input OFF OFF response approx 0.2 msec OFF ON 1 msec Default Setting ON OFF OFF 4 OFF ON OFF 10 msec 5 ON ON 100 msec Reset Range Select Value set using RESET trimpot on the front of the unit. SW1-5 SW1-6 Reset Time Range OFF OFF 4 to 100 msec OFF ON 4 msec to 1 Sec OFF ON OFF 4 msec to 10 Sec 6 OFF Only reset using Digital ON ON Inputs Relays/Opto Outputs Enable (this feature not implemented 7 yet) OFF = Relays/Opto Outputs Disabled OFF ON = Relays/Opto Outputs Enabled Run or Configuration Mode Select 8 OFF = Run OFF ON = Configuration danntech PROCESS INSTRUMENTATION 2016 Page 9 of 14

Configuration Mode When SW1-8 is ON then the configuration mode is activated. Only the relevant DIP switches may be used, i.e. only one switch between SW1-7 and SW1-2 (SW1-8 needs to be on to be in this mode and SW1-1 selects how to do the configurations using the analogue input or the trimpots). Table 2 Configuration Mode DIP Switch SW1 settings. SW1 Description This DIP switch performs two functions depending upon what is being configured: Default Setting 1 2 Input or Trimpot Selection for Output Calibration i.e. SW1-6 or SW1-7 is ON. OFF = Analogue Input is used to excite the output ON = The trimpots are used to excite the output, Zero Trimpot for minimum and Span Trimpot for the maximum. Digital Output Sense Select for Digital Output Setup i.e. SW1-3 is ON. This switch setting at the time of capturing the Digital Output Setpoint selects whether the respective Digital Output is active when the input goes from low to high (for a Peak), or from high to low (for a Valley). OFF = Low to High ON = High to Low Test Mode Repeated pressing of the push button sets the following on both outputs, repeated pressing restarts the cycle: Push Button Press Number Outputs follow the input as per normal 0 1 operation Outputs at absolute minimum (DAC output=0) 2 Outputs at 0% 3 Outputs at 50% 4 Outputs at 100% 5 3 Digital Output Setup 4 Input LED Setup 5 Input Calibrate 6 Output 1 Calibrate Outputs at absolute maximum (DAC output=4095) 7 Output 2 Calibrate 8 Run or Configuration Mode Select OFF = Run ON = Configuration OFF danntech PROCESS INSTRUMENTATION 2016 Page 10 of 14

Resetting to Factory Defaults Sometimes this is necessary if one gets things confused. To do this, switch all SW1 switches ON except SW1-8, then press the PB for >2 seconds. The factory defaults areas shown in the Table 2 Configuration Mode DIP Switch SW1 settings. [not yet implemented in V3.01] Trimming of Outputs Zero and Span Adjustment If the Zero and Span Trimpot are enabled (i.e. SW1-1 is ON in the RUN Mode) the outputs Zero and Span can be trimmed. Can only be done in the Run Mode. This is done by pressing and holding the Push Button (PB) for one second or more until the A2 LED first comes on and then shortly after, the A1 LED illuminates, this then sets the unit into the Output Trim mode. (if SW1-1 is OFF nothing will happen). The Peak LED will be on. Now you can trim the Peak Output Zero and Span using the trimpots. If you wish to move to the Valley Output without changing the Peak Output just press the PB briefly, this moves on to the next output without capturing the trimpot adjustments. If you wish to adjust the zero and span and capture the new values, press the PB for about 1 second until A2 comes on and then release, this will capture the new trimpot values for the Peak Output and move on to the Valley Output. Repeat until both the outputs are done. When the Valley Output is done the unit goes back into the Run mode. Input Range Selection DIP Switch SW1 # Input 1/A 2/B 3/C 4/D 5/E 6/F 7/G 8/H 4-20mA OFF ON ON OFF OFF OFF OFF ON 0-20mA OFF ON ON OFF OFF OFF OFF ON 0-100mV OFF OFF OFF OFF OFF ON OFF OFF 0-1V OFF OFF OFF OFF OFF ON ON OFF 0-10V OFF ON OFF ON OFF ON OFF OFF 0-30V (J3 in R2=620Ω) OFF ON OFF OFF OFF ON OFF OFF 0-100V OFF OFF ON OFF OFF ON ON OFF ±10V OFF ON OFF OFF ON ON ON OFF 0-2V (J3 in R2=1.1kΩ) OFF ON OFF OFF OFF ON OFF OFF danntech PROCESS INSTRUMENTATION 2016 Page 11 of 14

For self-powered ma input (normal operation) J1=A, J2=A For loop powered ma input (with fused +15 V supply) J1=B; J2=B Output Range Selection Information to follow. Analogue Input Setup Information to follow. Input LED Setup Information to follow. Analogue Output Setup Information to follow. Digital Output Setup Information to follow. danntech PROCESS INSTRUMENTATION 2016 Page 12 of 14

Specifications One analogue input, two isolated analogue outputs one for Peak (maximum) value and the other for Valley (minimum) value. Input and each output can be configured differently if required. For example the input can be 0-10 V, the Peak output can be 4 20 ma and the Valley output could be ±5 V. Galvanic isolation between input, power supply and each output > 1000 VDC. DC supply required 12 or 24 VDC, -5%, +10% at 100 ma max. Typical step response time (input to output) - less than 0.2 ms. Split rail powered input circuit to accommodate input signals from ±100 V down to ±100 mv or ±100 ma down to ±100 µa. Standard process signal inputs available, 0-10 V, 0-5 V, 0-2 V, ±10 V, 0-20 ma, 4-20 ma. Also factory configured currents 0 1 A, 0 5 A, 0 10 A AC or DC. Input impedance standard for voltage inputs at 100 kω but can be arranged to be 1 MΩ if required. Input impedance is 50 Ω for ma current inputs. DC coupled input signal as standard but can be arranged to be AC coupled if required. Analogue input resolution 0.1% of input range. Input sampling and processing frequency approximately 10 khz (100 µs). Minimum input pulse width for reliable detection 0.2 ms. Split rail powered output circuit - output signals from ±12 V down to ±100 mv. Output current for voltage output option at 5 ma. Output current range for current output option from 0 to 22 ma. Analogue output resolution 0.05% of range. Overall accuracy better than 1% of range. Output trimpot zero and span adjustments for each output on front panel. Reset time adjustable using trimpot beneath front panel from 0 to 100% of the selected range. Operating temperature -10 C to +70 C. Power On/Status green LED. Plug-in screw terminals which can accommodate wire up to 2.0 mm 2. DIN rail mounting enclosure - 22.5 x 100 x 113 mm (width x length top to bottom x height off DIN rail). Approximate weight 100 g. danntech PROCESS INSTRUMENTATION 2016 Page 13 of 14

User Manual The latest version of this User Manual can be found at: http://www.danntech.com/user%20manuals/peak_valley%20hold%20unit%20(pvhu)%20user Manual.pdf or by scanning in: danntech Ltd Co. No. 6510211 15 College Close, Hamble-le-Rice Southampton, Hampshire SO31 4QU United Kingdom Tel: 075 9069 1824 e-mail: sales@danntech.com www.uk.danntech.com www.danntech.com danntech cc Reg. No. CK1986/15338/23 Tel International: +27 11 7921239 Tel National: 011 7921239 Fax International: +27 11 7924687 Fax National: 011 7924687 e-mail: sales@danntech.com P O Box 1023, Fontainebleau, 2032 Republic of South Africa www.danntech.co.za www.danntech.com Danntech makes no warranty of any kind with regard to this material, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose. Danntech shall not be liable for errors contained herein or for incidental or consequential damages in connection with the furnishing, performance or use of this material. This document contains proprietary information, which is protected by copyright. No part of this document may be photocopied, reproduced, or translated into another language without the prior written consent of Danntech. The information in this document is subject to change without notice. danntech PROCESS INSTRUMENTATION 2016 Page 14 of 14