Operation Manual. Fieldbus system EX510-GDN1. DeviceNet Compatible GW unit

Similar documents
Operation Manual. Fieldbus system EX510-GPR1. PROFIBUS DP Compatible GW unit

Reduced wiring system. PROFIBUS-DP Compatible GW unit. Operation Manual EX510-GPR1. URLhttp://

Fieldbus system (DeviceNet compliant)

Doc. No.: EX**-OMC0024. Instruction Manual. SI Unit / DI Unit EX240-SDN2 EX240-IE1 SMC CORPORATION

OPERATION MANUAL E/P REGULATOR MODEL NAME. Series. For DeviceNet TM CONTENTS. Contents. Safety Instructions. Precautions for Handling P3-4

SI unit for EtherNet/IP TM EX250-SEN1

HITACHI. EH-150 series PLC EH-RTD8 Resistance Temperature Detective input module Instruction manual. Safety precautions

EtherNet/IP TM SI unit

Instruction Manual. Reduced wiring system EtherNet/IP Compatible SI Unit EX250-SEN1. URL

High Pressure E/P Regulator. ITVH Series

: EX##-OMC0024-A. Instruction Manual. SI Unit / DI Unit EX240-SDN2 EX240-IE1

SI unit for DeviceNet TM. EX180-SDN3/4/5/6 Series

Package Contents. GP Options (Made by Digital)

SI unit for IO-Link device

Fieldbus system (SI unit compatible CompoNet)

USER S MANUAL. FX2N-64DNET DeviceNet Interface Block

No.EX##-OMJ0001. SI unit for ControlNet PRODUCT NAME. EX250-SCN1 Series MODE/ Series

SI unit for IO-Link device

Preface. Copyright 1997, Digital Electronics Corporation MS-DOS and Windows 95 are registered trademarks of the Microsoft Corporation.

EX120/121/122 Series Some protocols are not CE-compliant.

H Series PLC. ! : Indicates Compulsion. EH-150 Analog input module EH-AXH8M Instruction manual. Safety precautions DANGER CAUTION COMPULSION

No.EX##-OMN0030-A. Fieldbus system DeviceNet TM compatible SI unit PRODUCT NAME. EX600-SDN#A EX600-ED# MODEL/ Series

Fieldbus system Analog unit

Conductive Level Controller

Operating instructions. Switching amplifier DN0210 DN / / 2015

Fieldbus system EtherCAT compatible SI unit

MPCR Series DeviceNet Technical Manual TDMPCRDNTM2-0EN 01/08 Subject to change without notice

This Datasheet for the IC670GBI002 24VDC BUS INTERFACE UNIT.

DC I/O Conversion Module FA-TB32XY

Sensing method Appearance Connection method Sensing distance Output Model. M12 connector 10±3 mm. Size Type Appearance Cable length Model Straight

EtherNet/IP TM Compatible Fieldbus System

Fieldbus system PROFIBUS DP compatible SI unit

Safety Precautions. Danger. Flex Network I/O Unit 32-point Input Sink Source / 32-point Transistor Output Sink Type Installation Guide.

Ethernet ITV Modbus TCP

DC I/O Conversion Module

Fieldbus system EtherNet/IP TM compatible SI Unit

NU-DN1. User s Manual. DeviceNet Compatible Network Unit

Flow Monitor PF2A20# PF2W20# PF2D20#

No.EX##-OMN0034. Fieldbus system CC-Link compatible SI unit PRODUCT NAME. EX600-SMJ# EX600-ED# MODEL/ Series

2002 Series DeviceNet Technical Manual

01348(N or G) MH** -- Material Handling (N or G) MH** -- Material Handling

Communications & Networking

No.EX##-OMN0028. Fieldbus system PROFIBUS DP compatible SI unit PRODUCT NAME. EX600-SPR#A EX600-ED# MODEL/ Series

Cable specifications PVC

Multi Channel Pressure Sensor Controller PSE200

No.EX##-OMN0036. Fieldbus system Digital unit PRODUCT NAME. EX600-DX## EX600-DY## EX600-DM## MODEL/ Series

MPCR Series DeviceNet Technical Manual

FR-A8AR INSTRUCTION MANUAL

KCH-B KCH-B. Merits. Application examples. Counters for Display of High-speed Addition and Subtraction. Counters. switches to write settings

G3 Series DeviceNet TM Technical Manual

DeviceNet Communication Converter COM-JH. [For FB100/FB400/FB900] Instruction Manual IMR01Y09-E5 RKC INSTRUMENT INC.

For Output. Series EX120/121/122. Small unit compatible with maximum 16 outputs Compatible with a variety of communication networks

Control unit SG-EFS 104/4L. EN Operating instructions. Innovative by tradition. Version SG-EFS 104/4L AC/DC 24 V

Twido Programmable Controllers Discrete I/O Modules

Operating instructions. Speed monitor D / / 2014

PROGRAMMABLE CONTROLLER. FP0 A/D Converter Unit. Technical Manual ARCT1F321E

Electrostatic Sensor Monitor IZE11

Series LC6D/LC6C. LJ1 LG1 LC1 LX LC6D/LC6C Switches LC6C LC6D. Series LX Dedicated Stepper Motor Driver and Positioning Driver

01325T -- Robot Welder

Enphase S-Series Microinverter and Engage Cable Safety

PC Wiring System. e-con type is newly added! One-touch connection reduces wiring labor. Series PCW

S82S (3/7.5-W Models)

1. Essential Safety Precautions

Preface. is the registered trademark of ODVA (Open DeviceNet Vender. Association). *1 Excluding the GP-3200 series.

FLEX Ex Spring Clamp Terminal Base

DeviceNet Communication Converter COM-JH. [For SRZ] Instruction Manual IMR01Y36-E3 RKC INSTRUMENT INC.

EC07 EC63. Compatible actuators: ERL2 ESD2. How to order EC 07 B. Series. B Installation. method

No.EX##-OMN0032. Fieldbus system EtherNet/IP TM compatible SI unit PRODUCT NAME. EX600-SEN# EX600-ED# MODEL/ Series

TOP - 1. Instruction Manual. Version 1.0 Produced in Jan. 2004

Technical Specifications

Appearance Size (mm) Power supply voltage Model (W H D) 100 to 240 VAC K3SC to 240 VAC

USER'S GUIDE FX-485ADP COMMUNICATION ADAPTER FX0N-485ADP COMMUNICATION ADAPTER

Digital Pressure Switch

BL compact fieldbus station for DeviceNet 16 Configurable Digital PNP Channels BLCDN-16M8L-8XSG-P-8XSG-P

FX1N-4EX-BD Input Expansion Board

S8VE (60/90/120/180/240-W Models)

FX2NC-ENET-ADP Ethernet adapter USER'S MANUAL

SMI-100 Stack Monitoring Interface Installation & Operation Manual

Programmable Controller Analog Terminal Block Conversion Module FA1-TBS40ADGN, FA1-TBS40ADDG, FA1-TBS40DAG User's Manual

GP-70 Series. User Manual. I/O Unit

M250 (M LL) Safety

EX12 -SCS1 EX12 -SCS2 EX12 -SSL1. SSL1: 0/16 SSL2: 0/8 Not provided 11 to 25 VDC 15 to 30 VDC 14 to 26.4 VDC 24 VDC+10%/ 5% 24 VDC+10%/ 5%

Switch Mode Power Supply

EX-RC1 Remote I/O Adapter

Preface Digital Electronics Corporation. All rights reserved. Digital Electronics Corporation December LT Type-D User Manual Supplement 1

M215 Safety (M LL-S22-IG / S23-IG / S24-IG)

BGS (at min. setting) BGS (at max. setting)

Terminal block 2 A 5 X 3. Specification

DIGITAL INPUT/OUTPUT RELAY INTERFACE BMS-IFDD01E

Documentation. KM2604 and KM2614. Four channel relay module. Version: Date:

DIN Rail Mounting Accessories. Style Appearance Use with Timers Part No. Appearance Part No. RTE-P2 SR3P Pin FingerSafe Socket RTE-P2 SR3P-05C

DTY-EPS DTY-EPU. w e DTY-EPP- - w e. t y. q DTY-EPU PSU-BR DTY-EPP-CC- L DTY-EPS. ZD1 ZD4 Tr1 Tr4

Digital Pressure Switch

Pressure Sensor Controller PSE300

Fieldbus System. New. New. Series EX260 IP67. Drives up to 32 solenoids. Daisy-chain wiring communication. Compact 28mm

1. Safety Precautions (Read these precautions before use.)

TOUCH SCREEN CONTROLLER for Air Conditioning Control System

Multi Channel Pressure Sensor Controller Operation Manual PSE200 Series

WARNINGS. *1 This mark is applicable only in Taiwan.

Fieldbus system EtherNet/IP TM compatible SI unit

Transcription:

Fieldbus system DeviceNet Compatible GW unit Operation Manual EX50-GDN URL http://www.smcworld.com Akihabara UDX 5F, --, Sotokanda, Chiyoda-ku, Tokyo 0-00, JAPAN Phone: +8-507-89 Fax: +8-598-56 Note: Specifications are subject to change without prior notice and any obligation on the part of the manufacturer. 00-07 SMC Corporation All Rights Reserved EX -OMH00-C

Table of Contents Thank you for purchasing an SMC fieldbus system EX50 series. Please read this manual carefully before operating the product and make sure you understand its capabilities and limitations. Please keep this manual handy for future reference. Safety Instructions Product Summary 6 Name of Parts/ Accessories 7 Dimensions 8 Settings 9 Specifications Wiring Display/ Switch Setting 9 OPERATOR This operation manual has been written for those who have knowledge of machinery and apparatuses that use fieldbus system and have full knowledge of assembly, operation and maintenance of such equipment. Please read this operation manual carefully and understand it before assembling, operating or providing maintenance service to the actuator. Troubleshooting

Safety Instructions The product and this manual contain essential information to protect users and others from possible injury and property damage and to ensure correct handling. Please check that you fully understand the definition of the following messages (signs) before going on to read the text, and always follow the instructions. Please read the operation manual of related apparatus and understand it before operating the actuator. Read this manual and follow its instructions. Signal words such as WARNING, CAUTI and NOTE, will be followed by important safety information that must be carefully reviewed. Indicates a potentially hazardous situation which could result in death or serious injury if you do not follow instructions. Indicates a potentially hazardous situation which if not avoided, may result in minor injury or moderate injury. IMPORTANT MESSAGES Gives you helpful information. Do not disassemble, modify (including change of printed circuit board) or repair. An injury or failure can result. Do not operate the product outside of the specifications. Fire, malfunction, or damage to the product can result. Verify the specifications before use. Do not operate in an atmosphere containing flammable or explosive gases. Fire or an explosion can result. This product is not designed to be explosion proof. If using the product in an interlocking circuit: Provide a double interlocking system, for example a mechanical system. Check the product regularly for proper operation. Otherwise malfunction can result, causing an accident. The following instructions must be followed during maintenance: Turn off the power supply. Stop the air supply, exhaust the residual pressure and verify that the air is released before performing maintenance. Otherwise an injury can result. After maintenance is complete, perform appropriate functional inspections. Stop operation if the equipment does not function properly. Safety cannot be assured in the case of unexpected malfunction. Provide grounding to assure the noise resistance of the product. Individual grounding should be provided close to the product with a short cable.

Safety Instructions (continued) Note When conformity to UL is required, the SI unit should be used with a UL0 Class power supply. Follow the instructions given below when handling your product. Or, it will have a risk of being damaged and operating failure. Operate product with the specified voltage. Reserve a space for maintenance. Do not remove labels. Do not drop, hit or apply excessive shock to the product. Follow the specified tightening torque. Never mount a product in a location that will be used as a foothold. Do not bend or apply tensile force to cables, or apply force by placing heavy load on them. Connect wires and cables correctly. Do not connect wires while the power is on. Do not lay wires or cables with power line or high-voltage line in the same wiring route. Verify the insulation of wiring. Separate power line for solenoid valves from power line for Input and control unit. Take appropriate measures against noise, such as using a noise filter, when the product is incorporated into equipment. Select the proper type of protection according to the environment of operation. Take sufficient shielding measures when installing at the following place. () A place where noise due to static electricity is generated () A place where electric field strength is high () A place where there is radioactive irradiation () A place near power line Do not use the product near by a place where electric surges are generated. When a surge-generating load such as a relay or solenoid is driven directly, use an product with a built-in surge absorbing element. The product is CE marked, but not immune to lightning strikes. Take measures against lightning strikes in the system. Prevent foreign matter such as remnant of wires from entering the product to avoid failure and malfunction. Mount the product in a place that is not exposed to vibration or impact. Do not use the product in an environment that is exposed to temperature cycle. Do not expose the product to direct sunlight. Keep the specified ambient temperature range. Do not expose the product to heat radiation from a heat source located nearby. Set the switches by using a sharp-pointed screwdriver etc. Turn off the power supply, stop the supplied air, exhaust the residual pressure and verify the release of air before performing maintenance. Perform maintenance and check regularly. Perform a proper functional check. Do not use solvents such as benzene, thinner etc. to clean the product. 5

6 Product Summary System structure Power supply for output VDC Power supply VDC for input and controling GW Input unit connector ( ) inputs type Input unit connector ( input type) connecting to ( sets maximum ) Connecting to bus at upper level (DeviceNet) GW unit Branch cable (EX50-FC ) Valve manifold with SI unit connecting to sets maximum ( ) The system which realizes wiring saving and distributed installation by connecting to DeviceNet. The signal to DeviceNet is transmitted by GW unit, and the signal to input/output device which is installed discretely is collected by GW unit. Name of Parts/ Accessories 6 8 7 9 5 0 Communication connector for DeviceNet ( piece) Accessory Power supply connector ( pieces) No. Parts Purpose Communication Connect to DeviceNet line with an accessory socket (BUS) connector for DeviceNet ( ). Power supply Supplying power for output instruments such as a socket ((V)) solenoid valve with an accessory connector ( ). Supplying power for controlling GW and for Power supply input instruments such as a sensor with an socket () accessory connector ( ). 5 GW unit side branch connector (for input) GW unit side branch connector (for output) Connecting an input unit etc. by using branch cables (EX50-FC ). Connecting SI unit (manifold valve) etc. by using branch cables (EX50-FC ). 6 FG terminal Used for grounding 7 Mounting hole Used when a unit is mounted with two M screws. 8 DIN rail mounting slot Used when a unit is mounted to DIN rail. 9 Display/ switch setting part Sets up the switch on such as LED display and address, I/O points. : For wiring method, refer to "Wring" in the "Operation Manual". 0 7

Dimensions (in mm) Settings 6 5.7 6 Mounted by screw 5 5 6 60 80 (V) INPUT COM D COM C COM B OUTPUT BUS M : Tightening torque : 0.8 Nm Mounted on DIN rail (V) INPUT OUTPUT BUS 70 5 Perspective drawing (tolerance 0.) COM A DIN rail (V) BUS 8 9

0 Settings (continued) Mounting Claw Claw Removal DIN rail fixing plate Put Claw of the body under DIN rail and push it upward. Push down Claw to the opposite rail until the claw clicks securely on to rail. (Mounting procedure and ) For removing, lever up the DIN rail fixing plate of the body with a flat blade screwdriver, and remove it by tilting Claw side forward. (Removal procedure and ) Specifications Basic specifications Rated voltage Power supply voltage Rated current Input/ output point Operation temp. range Higher-level bus Protocol Slave type VDC Power supply for input and controlling GW: VDC ±0% Power supply for output: VDC+0%/-5% (Warning for voltage drop is given at approx. 0 V) Power supply for DeviceNet: to 5 VDC Power supply for input and controlling GW: Max.. A (Inside GW unit: 0. A, input unit: A) Current for output: Max. 6 A Power supply for DeviceNet: 50 ma Input point: Max. 6/ Output point: Max. 6 (Changeable by switch settings) -0 to 50 o C DeviceNet Release.0 Group Only Server MAC ID setting 0 to 6 Vender code: 7 (SMC Corp.) Device information Product type: Product code: 00 Duplicate MAC ID Check Message Applicable message Group Only Unconnected Explicit Message Explicit Message, Poll/ I/O Message Input: Max. 8 byte, Output: Max. 8 byte I/O message size (Changeable by switch settings) Baud rate Max. length Thick cable of Network Thin cable Total extended cable length 5 kbps 500 m or less 50 kbps 500 kbps 50 m or less 00 m or less 00 m or less 56 m or less 78 m or less 9 m or less Note: Max. extended cable length is 6 m.

Specifications (continued) Lower level bus Number of branches for input/ output Communication type Current for input branch Current for output branch Branch cable length branches for input branches for output Communication protocol: Dedicated for SMC Communication speed : 750 kbps Max. A per branch Max..5 A per branch At 0.75 A per branch: 0 m or less At.0 A per branch : 6 m or less At.5 A per branch : 0 m or less : Input terminals are not isolated from Power source. : Do not connect outside Power source to Input and Output terminals. Wiring (continued) Branch wiring The wiring between each unit should use branch cables, and be connected with branch connectors. SI unit and Input unit have branch connectors for each. Pressure welding for branch connector The method of pressure welding for branch connector is explained. ()Components Insulating cap Pin no. display Brown Black White Blue Wiring Internal circuit Power supply for output Power supply for input and controlling GW V- CAN_L Drain CAN_H V+ FG + V 0 V + V 0 V CAN transceiver DC-DC converter (uninsulation) Communication part isolated circuit (Photo-coupler) DC-DC converter (isolated) Internal circuit (Brown) + V TD+ TD- 0 V + V RD+ RD- 0 V + V TD+ TD- 0 V + V RD+ RD- 0 V OUTPUT INPUT OUTPUT INPUT COM A COM D Cover Body Branch cable ()Working procedure Set a branch cable to the cover. Hold for ) Set the brown wire of the branch fixing latch cable so that it comes to the pin #. ) Meet the cable end to the insulating cap at the cover. ) Fold the cover so that the branch cable can be put between the cover. ) Fix the latch tip by inserting to a hole for fixing latch. Note) Check the color of wire written on a branch connector and the color of branch cable are same. Fix to a body tentatively. Fit latches on a body to ditches on the cover, and press them until the latch engages to the level. Pin #: Brown wire Latch

Wiring (continued) Press fitting Press the cover to the body with plier etc. Confirmation It is completed with a check on latches engaging. Wiring of branch cables Branch connector at GW unit side Branch connector at cable side branches for input branches for output COM D COM C COM B COM A Branch cable To SI unit To Input unit Insert branch connector on the table side from the bottom (COM A, B, C, D of branch connector of GW unit side). EX50 NOTE. Select a branch cable length suitable to avoid stress being applied to the branch connector and cable, and provide sufficient cable length for maintenance.. Do not pull the branch connector and branch cable after wiring. There is a risk of damage.. Do not open and close the branch connector hook repeatedly. There is a risk of damage.. Cut the branch cable and replace the branch connector when the branch connector hook is broken or no longer functions. 5. Use SMC branch connector (product No.: EX50-LC) and branch cable (product No.: EX50-FC ). Usage of other branch connector or cable is out of the applicable range of product guarantee. Communication wiring Connect DeviceNet dedicated cables to the communication connector for DeviceNet. () Make sure to connect the signal cables to designated pins (Refer to Drawing ). And tighten the connector surely to 0.5 to 0.6 Nm tightening torque. Black Blue Drain White Red V- CAN_L Drain CAN_H V+ Black Blue Drain White Red Drawing 5

Wiring (continued) () Make sure to connect a "terminating resistor" between "CAN_H"-"CAN_L" to the units at both ends of the system (Refer to Drawing ). Terminating resistor V- CAN_L Drain CAN_H V+ Black Blue Drain White Red Drawing () Refer to Drawing about how to connect to the unit. Communication connector for DeviceNet Power supply wiring Connect power supply wiring to the two power supply -pin connectors. Power supply structure consists of systems, but it can be used with both single power supply and separate power supply. Individual power supply for other units is not necessary. Make sure of connection with the designated pin. Tighten the connector securely to 0.5 to 0.6 Nm tightening torque. Power supply connector Power supply connector Power supply (V) for output Power supply for input and controlling GW Note: A secure earth connection (Protection class ) should be performed for FG terminal. Drawing 6 7

Wiring (continued) VDC A. For dual power supply use VDC B. For single power supply use Display/ Switch Setting Setting for Display SW SW COM A COM B COM C COM D INPUT (V) MNS VDC C. When used as power supply for DeviceNet (Power supply for output is another one) VDC When input unit is used It is necessary to make power supply for DeviceNet VDC ±0%. When input unit is not used Power supply for DeviceNet can be operated by to 5 VDC. Display (V) Meaning The power for output is supplied at specified voltage: Lights up The power for output is not supplied at specified voltage: Goes off The power for DeviceNet is supplied: Lights up The power for DeviceNet is not supplied: Goes off Power off, off line, or duplicate MAC ID: Lights off Waiting for I/O connection (online): Green flashing I/O connection completed (online): Green lights up MNS I/O connection time out: Red flashing (Light degree of communication error) MAC ID duplicate error, or BUS error: Red lights up (Heavy degree of communication error) COM A is receiving data: Lights up COM A COM A is having no data to receive: Goes off COM B is receiving data: Lights up COM B COM B is having no data to receive: Goes off COM C is receiving data: Lights up COM C COM C is having no data to receive: Goes off COM D is receiving data: Lights up COM D COM D is having no data to receive: Goes off : It is lit when input unit is connected and communicating normally. 8 9

Display/ Switch Setting (continued) Switch setting Make sure that switch setting is performed with power supply turned off. Open the cover, and set DIP switch with a small flat blade screwdriver, etc. Setting of MAC ID, Baud rate, HOLD/CLR and HW/SW mode (SW) Setting of MAC ID, Baud rate, HOLD/CLR and HW/SW mode are performed with SW. Communication speed HOLD/CLR MAC ID HW/SW MAC ID setting (switch No. to 6) All of the settings when shipped from plant are turned and the station number is set 6. Make sure to set the station number in the range of 0 to 6. MAC ID (No.) (No.) (No.) 8 (No.) 6 (No.5) (No.6) 0 0 : 0 : 6 6 SW 8 6 5 6 7 8 : : : : : : : : : : : : 9 0 Swtting of communication speed (switch No.7 to 8) Make sure to set the communication speed in the range as follows. All setting are turned at shipment, set to 5 kbps. Baud rate 5 kbps 50 kbps 500 kbps - No.7 No.8 HOLD/CLR setting (switch No.9) The setting is as follows. The setting when shipped from plant is turned, set to CLR. HOLD/CLR CLR HOLD Mode HW SW No.9 No.0 Function Output is cleared when an error occurs. Output is held when an error occurs. HW/SW mode setting (switch No.0) The setting is as follows. The setting when shipped from plant is turned, set to HW mode. Function Set MAC ID and baud rate with SW to 8. MAC ID and baud rate are set by network. : SW to 8 are ignored.

Display/ Switch Setting (continued) Input/Output setting (SW) Input/output setting is performed with SW. Number of input setting Number of output setting SW Input setting (switch No. to ), Output setting (switch No. to 6) The setting is as follows. All of the settings when shipped from plant are turned, 6 I/O points. No. No. No. Input point COM A COM B 6 6 6 0 6 8 8 6 6-8 8 6 6 Reserve 5 6 COM C COM D 6 6 8 8 Troubleshooting Overall system No. Item Solenoid valve is not working Valve is not working as program directs Signals cannot be received even with a sensor COM A-D is not LIT Remedy/ Disposal Check the power for output ( VDC) is supplied. Check the branch cable is connected to SI unit. Check the LED for power supply () and the LED for communication (COM) at SI unit are. Ensure output branch current does not exceed the specification range. Program it after checking the wiring specification of manifold block assembly. Check the power for input and controlling GW ( VDC) is supplied. Check the input unit indication LED is. Ensure input branch current does not exceed the specification range. Check the connection of UNLIT COM port branch to input unit. No. No.5 No.6 Output point COM A COM B 6 6 6 0 6 8 8 6 6-8 8 6 6 Reserve COM C COM D 6 6 8 8

Troubleshooting (continued) <MEMO> DeviceNet compatible communication No. Item LED is goes off Remedy/ Disposal Check the power supply for DeviceNet is supplied. Check the power for output ( VDC) is supplied. Check the power supply (V) LED is goes off voltage for output is above 0 V. Check the power for input and controlling GW ( V DC) is supplied. The status of MNS LED Not online: Goes off Check the signal line from Online, not allocated: Green flashing PLC is correctly connected. Online, allocated: Green lights up Check the wiring and pin Light degree of communication numbers. error: Red flashing Check the baud rate and Heavy degree of communication MAC ID setting is correct. error: Red lights up : Refer to "Operation Manual" for detail of troubleshooting. 5