Doc. No.: EX**-OMC0024. Instruction Manual. SI Unit / DI Unit EX240-SDN2 EX240-IE1 SMC CORPORATION

Similar documents
: EX##-OMC0024-A. Instruction Manual. SI Unit / DI Unit EX240-SDN2 EX240-IE1

Operation Manual. Fieldbus system EX510-GDN1. DeviceNet Compatible GW unit

EX120/121/122 Series Some protocols are not CE-compliant.

Series EX120/121/122. Integrated Type/For Output. How to Order SI Unit SV1000/2000/3000/4000 SY3000/5000 SY3000/5000 VQ1000/2000.

Operation Manual. Fieldbus system EX510-GPR1. PROFIBUS DP Compatible GW unit

For Output. Series EX120/121/122. Small unit compatible with maximum 16 outputs Compatible with a variety of communication networks

Reduced wiring system. PROFIBUS-DP Compatible GW unit. Operation Manual EX510-GPR1. URLhttp://

OPERATION MANUAL E/P REGULATOR MODEL NAME. Series. For DeviceNet TM CONTENTS. Contents. Safety Instructions. Precautions for Handling P3-4

EX12 -SCS1 EX12 -SCS2 EX12 -SSL1. SSL1: 0/16 SSL2: 0/8 Not provided 11 to 25 VDC 15 to 30 VDC 14 to 26.4 VDC 24 VDC+10%/ 5% 24 VDC+10%/ 5%

MAC VALVES, INC. A ENGINEERING RELEASE TRJ B EDS UPDATE / NAME CHANGE BI 284 TJR/KD. User s Manual for MAC Valves DeviceNet

HITACHI. EH-150 series PLC EH-RTD8 Resistance Temperature Detective input module Instruction manual. Safety precautions

SYSMAC Remote Transistor Module

Terminal block 2 A 5 X 3. Specification

H Series PLC. ! : Indicates Compulsion. EH-150 Analog input module EH-AXH8M Instruction manual. Safety precautions DANGER CAUTION COMPULSION

Communications & Networking

EX-RC1 Remote I/O Adapter

Fieldbus System (For Input/Output)

Preface. is the registered trademark of ODVA (Open DeviceNet Vender. Association). *1 Excluding the GP-3200 series.

CONTENTS 1. BEFORE USE GENERAL DESCRIPTION POINTS OF CAUTION HARDWARE SPECIFICATIONS... 4

Option 2. Nil. Note 1) Option 1. Note With waterproof seal and mounting screw. With waterproof seal and mounting screw. 48 conversion adapter

EX-RC1 Remote I/O Adapter

Instruction Manual. Reduced wiring system EtherNet/IP Compatible SI Unit EX250-SEN1. URL

USER S MANUAL. FX2N-32DP-IF Profibus-DP Interface Unit

USER S MANUAL. FX2N-64DNET DeviceNet Interface Block

Diagnostics (Logical) Diagnostics (Physical)

2002 Series DeviceNet Technical Manual

R7D-RR8 BEFORE USE... POINTS OF CAUTION. INSTRUCTION MANUAL REMOTE CONTROL RELAY CONTROL MODULE, 8 points MODEL. (DeviceNet)

SC SERIES. Up to 16 I/O devices can be connected at once using MIL connectors. Sensor-PLC Connection System WIRE-SAVING UNITS.

Fieldbus System. New. New. Series EX260 IP67. Drives up to 32 solenoids. Daisy-chain wiring communication. Compact 28mm

Operating instructions. Switching amplifier DN0210 DN / / 2015

The diagram below shows how cables and I/O modules are connected to form a plug-and-go system.

One step ahead in performance and mounting ease

Information. EX260 Integrated Type (For Output) Serial Transmission System 5 Port Solenoid Valve mm. Series SY/SV/VQC/S0700

Transistor I/O Link Modules

EX-RC1 Remote I/O Adapter

DeviceNet Communication Converter COM-JH. [For FB100/FB400/FB900] Instruction Manual IMR01Y09-E5 RKC INSTRUMENT INC.

IO-DI8-TO8, IO-DI8-TO8-L I/O Expansion Modules 8 Inputs, 8 Outputs

PROGRAMMABLE CONTROLLER. FP0 A/D Converter Unit. Technical Manual ARCT1F321E

Ultra-small U-shaped Micro Photoelectric Sensor. Extremely small size enables space saving!! 12 mm in

Modbus Digital Remote I/O. ARM Series. Modbus Sensor Connector Type Digital Remote I/O. Features. User Manual For Communication. Ordering Information

PM-24 SERIES. Ultra-small U-shaped Micro Photoelectric Sensor. Extremely small size enables space saving!! ( ) Equipped with two independent outputs

MPCR Series DeviceNet Technical Manual TDMPCRDNTM2-0EN 01/08 Subject to change without notice

panasonic.net/id/pidsx/global Up to 16 I/O devices can be connected at once using MIL connectors

Thread length (overall length) material

Connector Built-in U-shaped Micro Photoelectric Sensor. Approximately 60 % of previous model Detachable

NPN output PNP output Cord connection Cord length: 2 m Through-beam 7 m Light-ON. 2 m. (selectable by wiring) Diffuse reflective 0.

No.EX##-OMN0030-A. Fieldbus system DeviceNet TM compatible SI unit PRODUCT NAME. EX600-SDN#A EX600-ED# MODEL/ Series

Optimum sensing capability for LCD manufacturing

BL compact fieldbus station for DeviceNet 16 Configurable Digital PNP Channels BLCDN-16M8L-8XSG-P-8XSG-P

IO-DI8-TO8 I/O Expansion Module 8 Inputs, 8 Outputs

RS232C/RS485 Data can be easily monitored by LAN

3-step setting 2. 2-Color Display High-Precision Digital Pressure Switch. ZSE30A(F)/ISE30A Series. Added vacuum range.

GE FANUC Parts 1. DeviceNet Network Master/Slave August 2002 GFK-1539A. Quick Start Guide. Product Description. Specifications. Preinstallation Check

Operating instructions AS-i SmartLine module AC3200 AC /00 06/2016

Expansion Module HZS 541-1S

INSTRUCTION SHEET. Eaton Logic Controller DeviceNet Distributed I/O Adapter Module. [Applicable Distributed I/O Adapter Module] ELC-CADNET

Varispeed SERIES OPTION CARD DeviceNet COMMUNICATION INTERFACE CARD USER'S MANUAL Model: SI-N1

MPCR Series DeviceNet Technical Manual

S8VE (60/90/120/180/240-W Models)

G3 Series DeviceNet TM Technical Manual

KCH-B KCH-B. Merits. Application examples. Counters for Display of High-speed Addition and Subtraction. Counters. switches to write settings

E2A. Ordering Information. Cylindrical Proximity Sensor. Safe Mounting with Greater Sensing Distance. E2A Cylindrical Proximity Sensor 1

DeviceNet Communication Converter COM-JH. [For SRZ] Instruction Manual IMR01Y36-E3 RKC INSTRUMENT INC.

Suitable for detecting transparent films or transparent bottles

Preface. Copyright 1997, Digital Electronics Corporation MS-DOS and Windows 95 are registered trademarks of the Microsoft Corporation.

Thread length. 27 (40) mm. 27 (44) mm. 27 (40) mm. 34 (50) mm. 34 (49) mm. 39 (60) mm. 39 (54) mm. 44 (65) mm. 44 (59) mm

Ferrous metal (The sensing distance decreases with non-ferrous metal.) Power supply voltage (operating voltage range)

Compact performance. Brief description. CPV valve terminal with AS-Interface type CPV..-GE- ASI-8E8A-Z M8. English e [ ]

1. Essential Safety Precautions

ELC-CODNETM. Effective December Users Manual

Allen-Bradley Automation

IO-AO6X I/O Expansion Module 6 Isolated Analog Outputs

Installation Sensing distance Connection Output configuration Operation mode NO Operation mode NC

RAD-DO8-IFS. I/O extension module, eight digital transistor outputs. Data sheet. 1 Description

EC07 EC63. Compatible actuators: ERL2 ESD2. How to order EC 07 B. Series. B Installation. method

Model Number Structure

BL compact fieldbus station for DeviceNet 16 Configurable Digital PNP Channels BLCDN-8M12LT-8XSG-PD-8XSG-PD

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

G3PC. Model Number Structure. Solid State Relays with Failure Detection Function. Model Number Legend

Monitor. Safety relay,etc. Contactor, etc. Uses external device monitoring function Note: Construct a separate reset input circuit.

2. Actuator B: Ball type P: Pin type F: Flat type

Combine Relays and P7TF Block Bases to match your application requirements. Use the table below to configure Relay Blocks.

No.EX##-OMN0034. Fieldbus system CC-Link compatible SI unit PRODUCT NAME. EX600-SMJ# EX600-ED# MODEL/ Series

Making Hazardous Operations Safe and Productive

Fieldbus system Analog unit

GP-70 Series. User Manual. I/O Unit

Operating instructions. Speed monitor D / / 2014

Model Number Structure

E2EC-CR8D2 5.4 mm dia. 1.5 mm (0.06 in) NO E2EC-C1R5D1 NC. E2EC-C1R5D2 8mmdia. 3 mm (0.12 in) NO E2EC-C3D1 NC

IO-PT4. Component identification. User safety and equipment protection guidelines. Unitronics Industrial Automation Systems 1

Inductive Proximity Sensor

G9SX-GS. Safety Guard Switching Unit. A Safety Measure for Hazardous Operations That Does Not Lower Productivity. Auto Switching Function

High Speed Remote I/O Module

Inductive Proximity Sensor

DC 3-wire Cylindrical Inductive Proximity Sensor. Long sensing range

Compact Inductive Proximity Sensor

Analog Input Installation Manual

BL compact fieldbus station for DeviceNet 4 Analog Inputs for Current or Voltage and 8 Configurable Digital PNP Channels BLCDN-8M12L-4AI-VI-8XSG-PD

Series LC6D/LC6C. LJ1 LG1 LC1 LX LC6D/LC6C Switches LC6C LC6D. Series LX Dedicated Stepper Motor Driver and Positioning Driver

Installation, Operation and Maintenance Manual

Transcription:

Doc. No.: EX**-OMC00 Instruction Manual SI Unit / DI Unit EX0-SDN EX0-IE SMC CORPORATION

SAFETY INSTRUCTIONS (Read carefully before use.) Thoroughly read this technical instruction manual and related manuals mentioned here to ensure the safety and proper operation of the product. Level of potential hazard! Warning: Operator error could result in serious injury or loss of life.! Caution : Operator error could result in injury or equipment damage. Thoroughly read this manual! Caution Thoroughly read this manual and operate the product within the specified range following every instruction. Handle with care Do not drop the product and/or give excessive impact on the product. Keep the specified voltage range An operation error, breakage, electric shock and fire may occur if the product is operated with voltage out of the specification. Do not touch terminals and/or internal circuit board while they are energized An operation error, breakage or electric shock may occur if you touch energized terminals and/or internal circuit board. Keep the ambient temperature specification Use within the specified ambient temperature. Do not use the product in an atmosphere subject to a sudden temperature change even if the temperature is within the specified range. Avoid foreign matter from getting inside the product Make sure that foreign matter such as bits of wire does not enter the product. It may result in a fire, failure or operation error.! Warning The product is designed to use in ordinary full automation equipment. Prevent the use in machinery and/or equipment where human life may be directly injured and malfunction or failure may cause enormous loss. Do not disassemble the product for maintenance or modifications.

CONTENTS Outline... Part numbers... System components... Appearance... 5 Connector... 5. Power supply connector... 5. Communication connector... 5. Input connector...5 6 Display...5 7 Wiring...6 7. Power supply wiring...6 7. Connection style...7 7. Input wiring...8 8 Solenoid valve...9 9 Setting...0 0 Specifications... Input/Output No. assignment... Installation & Maintenance...6 EDS (Electronic Data Sheet) File...8 Troubleshooting...9

Outline DeviceNet A Network which is compatible and exchangeable with equipment from various manufacturers since communication specifications are opened. Serial interface unit (SI unit) for DeviceNet As a slave of DeviceNet, it is possible to control switching (ON/OFF) of solenoid valves up to points. This distributed I/O device also allows sensor signals for the maximum of points to be input (digital input) by connecting discrete input unit. IP65 is satisfied. Discrete input unit (DI unit) An expansion unit to input with sensor such as auto switch by connecting to SI unit. Each DI unit is able to take sensor input up to 8 points and set it to sensor by using NPN/PNP change-over switch. Up to pieces of DI units can be attached to SI unit for expansion. IP65 is satisfied. Part numbers EX0 - SDN EX0 - IE EX0 - EA SI unit for DeviceNet (NPN output) 8 point - input DI unit End case assembly System components Master DeviceNet transmission line Power supply line DI unit 0 no input points of input Manifold solenoid valve SI unit DI unit DI unit DI unit DI unit End case assembly solenoids at the maximum Input No. 0 7 8 5 6 Sensor (Auto switch)

Appearance SI unit display window DI unit display window End case assembly Communication connector SI unit Power supply connector DI unit DIN rail mounting bracket

Connector 5. Power supply connector Franz Binder Series 7 5 pins (709-05-80-05 ) Connector example for cable: Franz Binder 709-0-70-5 DIN type 5 pins No. Description Function SVV SV0V + V for solenoid valve 0V for solenoid valve 5 PE SWV Protection earth + V for Sensor unit 5 SW0V 0V for Sensor unit 5. Communication connector OMRON M 5 pins (For DeviceNet only) Connector example for cable: OMRON DCA-5CN05F KARL LUMBERG RKT5-56 No. Description Function Drain Drain/Shield 5 V+ V- Power for line + Power for line - 5 CAN_H CAN_L Signal line H Signal line L Compatible with Micro Style connector with DeviceNet specifications

5. Input connector M 5 pins compatible with OMRON XSF 8 pcs. Connector example for cable: OMRON XSG No. Description Function SW+ N.C Supply power + for sensor Free 5 SW- SIGNAL Supply power - for sensor Sensor input signal 5 PE Protection earth for sensor No. pins of connectors with input No. 0,,, and 6 (connectors on the right side of each DI unit) are internally connected to No. pins of input No.,, 5 and 7 (sensor input signals), respectively. This allows direct input for points which are put in one cable with a collective connector. Connector: Input no. 0,,, 6 Input no.,, 5, 7 SW+ SIGNAL-n+ SW- SIGNAL-n PE 5 5 NOTE: Use water-proof cover on unused input connectors in case protection structure is necessary equivalent to IP65. Please order the water-proof cover separately. Ex: OMRON XSZ- 6 Display SI unit DI unit PWR(V) PWR MOD/NET Descp. PWR(V) PWR MOD/NET Function Lights up when power for solenoid valve is supplied Lights up when power for DeviceNet line is inputted Lights off: power off, off line, or duplicate check MAC_ID Green flashing: waiting for connection (online) Green lights up: connection completed (online) Red flashing: connection time-out (light degree of communication error) Red lights up: MAC_ID duplicate error, or BUSOFF error (Heavy degree of communication error) PWR 0 5 6 7 Descp. PWR 0 7 Function Lights up when power for sensor is supplied. Lights off when short-circuit suppressor works. Lights up when each sensor input turns on. 5

Wiring 7. Power supply wiring Power supply line inside the unit has individual power supplies for solenoid valve actuation (SV power supply) and for Sensor (SW power supply). Supply DCV for each of them. Either single or individual power supply is available. Wiring is not necessary for SW power supply when input unit is not used. DCV Power supply cable with shield Power supply cable with shield DCV PE SW power SV power supply supply Power supply connector DCV A. Individual power supply B. Single power supply PE SW power SV power supply supply Power supply connector Power for sensor is supplied to sensor connected with DI unit. Select sensor concerning voltage drop up to approx. V inside the unit at this moment. If sensor requires V, it is necessary to lower power supply voltage for sensor slightly or secure power supply for sensor separately without going through SI unit so that sensor input voltage can be V with actual loading (allowable voltage of sensor power supply: 9.V to 8.8V). Approx. V of voltage drop Sensor DCV V SI unit DI unit Select power supply cable sufficient for power consumption and number of stations of solenoid valves, and current consumption of SI unit and sensor. Wire power supply cable to plug properly and then connect it to socket of SI unit. FRANZ BINDER 709-0-70-05 SI unit 6

7. Connection style T branch, multi branch, branch line branch, and multi drop connections are available for DeviceNet. Longitudinal extension of main and branch line are different depending on the communication speed. Also, it is different depending on thick and thin line of communication cable, please refer to following table. Terminating resistance T branch Main Terminating resistance Node Node Branch line branch Branch line Multi branch Node Node Node Branch line Node Max. 6m Node Node Wire length Communication speed (kbps) 5 50 500 Max. length of Thick cable 500m or less 50m or less 00m or less Network Thin cable 00 or less Total length of branch line 56m or less 78m or less 9m or less Note: Max. length of a branch line is up to 6m. Terminating resistance (/w) Cable specifications Item Thick line Thin line Signal Power Signal Power Conductor cross section 0.8mm².65mm² 0.0mm² 0.mm² Color Blue, White Red, Black Blue, White Red, Black Impedance 0 0% -- 0 0% -- Propagation delay.6ns/ft --.6ns/ft -- Attenuation factor Conductor resistance 500KHz: 0.5dB/ft 5KHz: 0.dB/ft.00MHz: 0.0dB/ft -- Branch line 500KHz: 0.50dB/ft 5KHz: 0.9dB/ft.00MHz: 0.70dB/ft 6.9 /000ft.6 /000ft 8 /000ft 7.5 /000ft -- Node! Wiring Instruction Please prepare plug connector for T type branch at customer in order to have multi drop connection. (Ex. TMSTBP.5...-STF-5.08 Phoenix Contact Co., Ltd.) Use connection cable for DeviceNet cable. The terminating resistor for DeviceNet should be used at the both end of mains. 7

7. Input wiring Input connector allows connection with plug for M sensor of the following specifications. No. of pins or 5 pins AC / DC DC NOTE: Use water-proof cover on unused input connectors in case protection structure is necessary equivalent to IP65. Please order the water-proof cover separately. Ex: OMRON XSZ- Input circuit diagrams DI unit V Cut-off circuit R Power supply (+) Output - wire sensor (NPN) Internal circuit 0V DI unit V Cut-off circuit R NPN/PNP chgo. SW. R Power supply (-) Power supply (+) Output - wire sensor (PNP) Internal circuit R NPN/PNP chgo. SW. Power supply (-) 0V DI unit V Cut-off circuit R (+) - wire sensor Internal circuit R NPN/PNP chgo. SW. (-) 0V Allowable supply current for sensor is 500mA per DI unit at the maximum. For DI unit to which 8 pieces of sensors are connected, approximately 60mA can be supplied per point. If excessive current flows into sensor power supply due to short circuit, power supply is stopped by cut-off circuit. In such a case, solve the problem, cut power once and then supply it again for return. 8

Example of sensor connection M plug for sensor Example: OMRON XSG Collective connector Example: OMRON XSR-D- Auto switch Air cylinder Connector cable Example: OMRON XSW-D*-*8-* Solenoid valve Part numbers of manifold solenoid valves which can be connected to SI unit are shown below. Series SY5000 SX000 VQ000 VQ000 How to order Series SX/SY IP65 SI unit mounting position Input unit specification For DeviceNet No. of input units Series VQ For D side mounting For DeviceNet No. of input units IP65 Input unit specification For details, such as manifold specifications, refer to catalogues and materials of each manifold solenoid valve. 9

9 Setting DIP switch setting Power of SI unit should be turned off while setting the DIP switch. DIP switch ON 5 6 7 8 9 0 0 Address setting Address SW. SW. SW. SW. SW.5 SW.6 8 6 0 0 0 0 0 0 0 0 0 0 0 0 0... 6 0 6 Communication speed setting communication SW.7 SW.8 speed 5kBPS 0 0 50kBPS 0 500kBPS 0 unused Mode setting 0 HW mode Set address and communication speed by SW.~8. SW mode Set address and communication speed via network. SW.~8 is invalid. Output setting at communication shutdown SW.9 Output condition of solenoid valve at communication shutdown (I/O connection time out), fault message All output hold (Fault action= Fault value=0) 0 All output clear (Fault state=0 Fault value=0) 0

NOTE Node address6 communication speed 5kBPS is set at delivery (Both HW mode and SW mode). Address and communication speed set at SW mode is maintained even after power of SI unit is turned off. Also, when turning on power at HW mode, address and communication speed set at SW mode is deleted and address and communication speed set by switch is memorized. SW mode HW mode SW mode Address: 6 Communication speed: 5kBPS Address: 0 Communication speed: 500kBPS Address: 0 Communication speed: 500kBPS Output setting for communication shutdown is 0 (all output clear mode) at delivery. Further, output setting for communication shutdown is possible to change the setting individually for point via network of DeviceNet. In this case, setting of SW.9 is invalid. Input circuit setting It is possible to change input circuit setting (NPN / PNP sensor input) for every DI unit. Disconnect DI units each other and set them individually. See. Installation & Maintenance for disconnection and connection of units. PNP input NPN input NPN/PNP change-over switch

0 Specifications Communication specifications Protocol DeviceNet Release.0 Communication speed 5k, 50k, 500kbps MAC ID setting range 0~6 Slave (branch) type Group Only Server Input points not depend on number of DI units Output points not depend on points of solenoid valves Device information Device type : 7 (Pneumatic valve) Product code : 0 Vendor ID : 7 (SMC Corp.) Corresponding message Explicit Polled IO General specifications EX0-SDN EX0-IE Dimension (W H D 5 88.5 0 * 5 7. 0 * Weight 00g * 70g * Ambient temperature 0 50 C Ambient humidity 0 95%RH without condensation Applicable altitude Less than 000m above sea Vibration proof 0 57Hz 0.5mm constant amplitude 57 50Hz 5G constant speed Shock resistance Peak value : 5G / ms times each in directions of ± X,Y and Z Enclosure *) Attachments excluded. IP65

Electrical specifications Rated voltage Power supply voltage Current consumption Withstand voltage Insulation resistance Momentary power failure Applicable load Driving current / Residual voltage Driving circuit DCV Power supply for solenoid valve.6 6.V (warning of voltage drop given at approx. 9V Power supply for SI units: 5V Power supply for DI unit: 9.~8.8V Power supply for solenoid valve depends on solenoid valve specifications and number of stations. Power supply for SI/DI units 00mA (at Min. power supply voltage for SI unit) sensor supply current AC500V min. (between PE external terminal package) 0M Ω or more (DC500V meg. between PE external terminal package ms power supply for SI/DI units solenoid valve with.w or less of light and surge voltage suppressor 00mA / 0.V Max. at ON N-ch MOS-FET open drain Input specifications Standard IEC- Corresponding sensor Current source type PNP output Current sink type NPN output * Rated voltage Ue DCV * Logical input voltage UH 0V Logical 0 input voltage UL - 5V Logical input current IH 8mA Typ. Connection of -wire type sensor Possible Logical 0 allowable current IL.5mA Max. Input delay ms Typ. Sensor supply current 500mA / DI unit 60mA Max. / sensor Short circuit suppressor 600mA Typ. for each SI unit supply power cut Cut power once and then supply it again for return. *) Changed over by switch (for every DI unit *) Approx. V of voltage drop for power supply voltage (power supply for SI/DI units)

Input / Output No. assignment SI unit input/output data (Poll command send/receive data) Item Output (Poll request) Input (Poll response) Occupied byte byte (solenoid valve output) byte (sensor input) Address+0 Output No. 0~7 Input No. 0~7 send/receive Address+ Output No. 8~5 Input No. 8~5 data Address+ Output No. 6~ Input No. 6~ Address+ Output No. ~ Input No. ~ *)Assignment method of send/receive data is different by PLC. Refer to PLC master (scanner) manual for the detail.

Correspondence between output data and solenoid valve Output data Bit 7 0 Offset0: Bit 7 0 Offset: 0: Solenoid valve ON : Solenoid valve OFF Bit 7 0 Offset: Bit 7 0 Offset: Bit No. 7 5 7 5 Output No. 9 7 9 7 5 No. of stations 6 5 9 5 Side U Solenoid on side B Side D Output No. 0 8 6 8 6 0 Solenoid on side A Bit No. 6 0 0 6 0 Valve manifold Output numbers are assigned to stations from side D to U of manifold in order (See manual of each manifold solenoid valve for the directions of side D and U.) Standard manifold is wired in double. Station No. no. No. Output numbers are assigned to side A Double 5 and B alternatively. In case of single solenoid valve, output on side B is free. Single Double 0 Free Mixed (single and double) wiring is Station No. no. No. available as long as wiring specifications designate it. This allows output numbers to be specified without having free output. Each bit of data sent from master ( bytes) shows ON/OFF 0: OFF : ON of solenoid valve. Starting from LSB of the first byte (Offset0), output numbers are assigned to all the bits in numeric order. Double Single Double - 0 5

Installation & Maintenance Installation Fix DIN rail for mounting SI/DI unit to the position where the unit is installed. Set SI/DI units on DIN rail and fix them with mounting brackets. End case SI unit / DI unit DIN rail Mounting bracket Fix manifold solenoid valve with mounting screws. Ground PE (protective earth) terminal (Type installation). Back of unit PE terminal Arrange wires (for power supply, communication and input) and pipes. Unit expansion and disassembly Disconnect units each other by loosing screws of modular adapter. Slide unit in lateral direction for disassembly in condition that modular adapter is unscrewed. Follow the same procedure to separate manifold - SI unit and SI/DI units - end plate. 6

For connection by the unit, follow the procedure backwards. Make sure that joint is properly set. If not, liquid and particles may enter the inside of unit. Check the following points to confirm proper joint setting. No missing joint. No breakage, falling and twist in joint packing. No foreign matter adhered. No inclined mounting. Keep tightening torque specification for modular adapter. If tightening torque is insufficient or modular adapter is inclined, liquid and particles may enter the inside of unit. Modular adapter Joint Sliding direction Square nut Tightening torque Kgf cm To add DI units, remove end plate following the procedure above. Put it back when additional DI units are attached. SI unit DI unit DI unit DI unit End case SI unit DI unit DI unit DI unit DI unit End case 7

EDS (Electronic Data Sheet) File EDS file describes ID information of SI unit and important information for the operation. Controller of DeviceNet or scanner recognizes SI unit automatically referring the EDS file. 8

Troubleshooting NET LED Light off Green flashing Green light on Cause and Countermeasure PWR LED is also lighted off <Countermeasure> Confirm if power for SI unit line is supplied. Confirm if cable for line is correctly wired. Replace SI unit if condition is not improved with above countermeasures. PWR LED is lighted on <Countermeasure> Confirm if communication speed is set correctly. Replace SI unit if it is lighted off even though the communication speed is set correctly. Connection standby Indicates standby condition of communication between SI unit and Mater. <Countermeasure> Confirm if master is operating correctly. If scan list is used, confirm the slave is registered on the scan list correctly. Communication is shutdown <Countermeasure> Confirm if CPU unit of PLC is operating. 9

MOD/NET LED Red flashing Red light on Cause and countermeasure Communication line cut off error <Countermeasure> Confirm if communication line is not cut off. <Note> Red light also blinks when power of master is OFF during communication. Node address error <Countermeasure> Confirm if there is a node with duplicated node address. BUS OFF error Communication error is found. Communication failure by noise is possible Confirm if there is such as equipment or high pressure line which cause noise around communication line. Measure to separate communication line from source of the noise. Problem on wiring of communication line is possible Confirm if terminating resistance ( )is connected on the both side of main communication line. Replace SI unit if red light of MOD/NET LED is on even though above countermeasures are performed.! Note SI unit will not recover automatically if red light of MOD/NET LED is on. Please supply power of SI unit line (communication and internal power) again. P505-9- 0