Instrument Current Transformers

Similar documents
Company Profile Principal Business

3a. IEM Indoor Metal Clad Medium Voltage Switchgear 25KV a. Section INDOOR METAL CLAD MEDIUM VOLTAGE SWTICHGEAR (Std.

Elastimold Molded Vacuum Recloser - MVR

Meter Enclosure and Equipment Standards

TECHNICAL SPECIFICATION FOR MEDIUM VOLTAGE METAL-CLAD SWITCHGEAR (15 KV)

Industrial Control. 50 to 5,000 VA. Applications. Specifications. Standards. Options and Accessories. Features, Functions, Benefits.

8 Submersible Motors Hi-Temp 75

S&C IntelliRupter PulseCloser Fault Interrupter Overhead Source-Transfer Application

ENERGY /// TE'S CROMPTON INSTRUMENTS TE'S CROMPTON INSTRUMENTS CURRENT TRANSFORMERS

Modular Splicing FAX MODULAR SPLICING. Modular Splicing Kits 305 Cable Adapter Kits 308

SECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS

SECTION SWITCHBOARDS

920 Remote Control (RC) Switches

Industrial Control. 50 to 5,000 VA. Applications. Specifications. Standards. Options and Accessories. Features, Functions, Benefits.

INSTRUMENT TRANSFORMERS

HID. GE Consumer & Industrial Multilin. High Impedance Differential Module Instruction manual GEK Copyright 2005 GE Multilin

ASCO 920 Remote Control (RC) Switches

Figure 1. Storm Trapper H. E. arrester, external mount. Figure 2. Storm Trapper H.E. arrester, metal enclosed. use in Storm Trapper H.E. arresters.

MRT1 Test Unit. Manual MRT1 (Revision A)

ELG4125: System Protection

Medium-Voltage Circuit Breaker-Type Automatic Transfer Switches and Bypass/Isolation Switches

SENSOR TECHNOLOGY IN A MEDIUM VOLTAGE SWITCHGEAR FOR THE US MARKET APPLICATIONS

SIEBREAK-VCB 5-15 kv metal-enclosed interrupter switchgear usa.siemens.com/siebreak

Maximum Reliability & Excellent Value. Features. UL Listed Withstand & Close-On Ratings. Series 300 Power Transfer Switches

8 Submersible Motors Standard

I-Line Panelboards. Innovative design, smart bus technology, and simple installation

Crane Control Contactors and Relays

Power Control Systems

SOUTH CAROLINA ELECTRIC COOPERATIVES SECONDARY TYPE 1 SURGE PROTECTIVE DEVICE SPECIFICATIONS Updated/Revised: October 6, 2014

24973 Circuit Breaker MINIATURE CIRCUIT BREAKER, 440VAC, 10A, CIRCUIT BREAKER TYPE: STANDARD

INSTALLATION PRODUCTS CAA GROUP OCTOBER 2018 Elastimold. Tru-Break switchgear module

PROTECTION RELAYS: INNOVATIONS FOR THE BENEFIT OF THE USER

Entry Level Assessment Blueprint Electrical Occupations

4.3. Switchboards. Contents Description Pow-R-Line Drawout Molded Case Circuit Breaker Switchboards Product Selection...

5.1. Motor Protection and Monitoring. Contents. Product Overview. Monitoring Relays. D64R Series Digital Ground Fault Relays...

SECTION DISTRIBUTION SWITCHBOARDS

PlexPower Factory Sealed Panelboard Increased Safety

SECTION 16450: NON-AUTOMATIC TRANSFER SWITCH / QUICK CONNECT GENERATOR SWITCHBOARD <S> <OM>

29 $ Manual Motor Starters FREESHIPPING. MOTOR CONTROLS 25. Features: MMS-32H Frame. MMS-63H Frame.

DIGITAL VOLTAGE INDICATOR

MG24434 Supplementary Protector SUPPLEMENTARY PROTECTOR, 240VAC, 16A, CIRCUIT BREAKER TYPE: STANDARD

Section 20 Distribution (Underground)

SSV-T and SSC-T High Drop-out Relay. Range amps amps amps amps. Operating Frequency: Temperature Error:

Crompton Instruments Ebony Current Transformers

Applications & Features, Type SSMP When using blind mate connectors in an application, careful consideration has to be given to choosing the right con

S&C IntelliRupter PulseCloser Outdoor Distribution (15.5 kv and 27 kv)

RL Line/Load Reactors

Refurbishment of Switchgear and Switchgear Devices

Han PCB termination. Han-Fast Lock PCB adapter for Han DD PCB adapter for Han DDD module

Lift Truck Parts Professionals

Energy Division. Crompton Instruments Ebony Current Transformers

IIM Warwick Court. Williamsburg VA REV 5

File E Project 12SC February 9, 2013 REPORT. Component - Protectors, Low-voltage Solid-state Overcurrent

FT & RT Test Switches

.2 Section General Commissioning (Cx) Requirements. .3 Section Common Work Requirements - Electrical

1S20. Arc Fault Monitor Relay. Features. Introduction. ARC Fault Protection

Model HU-224/225. Technical Information TI.224/ Humidity Transduce r FOR ADDITIONAL INFORMATION SEE HU-224/225 DATA SHEET

ABB Digital medium-voltage switchgear

Remote Real-Time Measurements of Voltage, Current and Energy

P Series PlexPower Distribution Panelboards Increased Safety

NF44E-.. / NFZ44E-.. Contactor Relays AC / DC Operated - with Screw Terminals

60103 Circuit Breaker

Spending too much to maintain aging switchgear? Circuit breaker solutions from Square D Services.

TAPE WOUND, SPLIT CORE AND EBONY CURRENT TRANSFORMERS

DIN Molded Cable Assemblies

Power Supply and Fan Module Installation

Section 21. Telecommunication Hardware. BuyLog Catalog 21-1

Inverter Selection Guide

ENCAPSULATED TRANSFORMERS FOR HAZARDOUS LOCATIONS

Limit Switches E47 Precision Switches

MAG. ECO FLO imag Series NSF FEATURES

SECTION SWITCHGEAR

System Accessories. features and benefits. standards. An Evolant Solutions Product

AE/CE Series Industrial Control Transformers

FT Flexitest Family. Switches, Covers and Test Plugs

Non-conventional instrument transformers Advanced GIS substations with IEC LE process bus

PGR-6101 MANUAL GROUND-FAULT & INSULATION MONITOR

PGR-6100 MANUAL GROUND-FAULT & INSULATION MONITOR

1.2. Loadcenters and Circuit Breakers. Contents. Overview. Type BR Loadcenters and Circuit Breakers. Product Selection Guide.

M E M O R A N D U M I.S.

This Datasheet for the IC697CHS790. Rack, 9 Slots, Rear Mount.

Mini Contactors & Overloads

MRCT Megger Relay and Current Transformer Test Set

Enhancing Reliability of Legacy Systems with New Generation Low-Voltage Circuit Breaker Upgrades

MICHIGAN DEPARTMENT OF TRANSPORTATION

Appendix D. EMC Installation Guidelines. Safety Considerations. Ferrite Absorbers and P-Clips. General Product Philosophy

ECET 211 Electric Machines & Controls Lecture 6 Contactors and Motor Starters (1 of 2) Lecture 6 Contactors and Motor Starters

Table of Contents. Introduction... 2 Description...2 Specifications...3 Installation.. 5 Calibration.. 6 General Maintenance...7

Slot Resistance Thermometers

Products Portfolio. Pole mounted Vacuum Recloser

PDI Modular Compact Remote Power Panel

Plug and Operate Transformer Technology

OPERATING INSTRUCTIONS. For the KNOPP TYPE KCTS-8000 CURRENT TRANSFORMER TESTING SYSTEM. Serial Number: Leaflet Number G.

AE/CE Series Industrial Control Transformers

Commodore SS Model CD General Specifications

ENhanced TEChnology. Solid insulated vacuum recloser for power distribution system thru 15kV, 27kV, 38kV. Ver.

Motor protection relays

CONNEX. The Plug-in Connection System for Power Transformers and Gas-Insulated Switchgear. the power connection THE PFISTERER GROUP

The City of Winnipeg Dry Type Transformers up to 600 V Primary Section Bid Opportunity No Page 1 of 2

SECTION METAL-CLAD MEDIUM VOLTAGE SWITCHGEAR (VacClad-W)

Transcription:

Catalog No. 4B Instrument Current Transformers 600 volt - 15Kv Reliability and Quick Results Reliability and quick response are the reasons you should select a Piedmont Current Transformer or have us build a custom unit for you! Piedmont Bushings & Insulators is an integrated manufacturer of toroidal wound current transformers and sensors. Not only have we been making current transformers for better than 40 years we have many years experience in the design of electrical insulation. Insulation failures of our transformers over the years are virtually non existent. We have many hundreds of standard current transformers for you to choose from, and by using in-house developed computer programs new designs can be readily available. Using high grades of silicone steels we wind and anneal our own cores, apply the winding, package this basic CT by either taping it, capturing it in an injection molded case, or encapsulating it in urethane or epoxy. Every transformer is tested to the applicable ANSI or IEC Standard, and a permanent record kept of its serial number and performance. Certified test reports are available when called for. Current transformers are classified by their current and voltage rating, accuracy class, physical configuration, and application.. Those differentiated by their application may be either relaying type or metering type. The relaying type have greater output and are generally larger and more expensive. Those differentiated by their configuration may be either window type or bar type. Piedmont makes many general purpose, 600 volt window type transformers for both metering and relaying applications. When used with our high voltage bushings the assembly has the rating of the bushing. We also make a substantial line of 5Kv, 15Kv and 25Kv bar type transformers for both metering and relaying applications. Please select from this brochure the current transformers that meets your needs. Or, if you need help call, fax, or e-mail your requirements and we will respond promptly. Piedmont Bushings & Insulators, LLC 251 Harris Bridge Road Post Office Box 849 Woodruff, South Carolina 29388 Phone: 864-476-6360 Fax: 864-476-6376 www.pb-i.com

Piedmont Bushings & Insulators, LLC 600 volt - Relaying Type 4B The 600 volt BHK and BG range of current transformers are suitable for relaying and metering applications, and are specifically designed for 15Kv and 26Kv metal clad switchgear. The 9.88 square design complements the 10 inch pole spacing of that equipment. One or two of the transformers can be slipped over the primary disconnect bushings. The BHK comes in two window sizes, 5.25 and 6.5 diameter. The BG is available in the larger size only. Both the BHK and the BG are made in ratios from 50:5 to 5000: 5 amperes, both single and multi ratio. The BHK-22 single and multi ratio transformers are available in Noryl plastic cases up to 2000 amperes. Above that, to meet the continuous current rating factor of 1.33 or better, they are encapsulated in polyurethane which more efficiently conducts the heat away from the core and coil. The BHK-22S single and multi ratio transformers are also encapsulated, as are all the BHK-23. At the present time all the BG current transformers are encapsulated. The secondary terminals consist of a 10-32 insert in the molding. A 10-32 x 3/8 binding head screw is recommended. TYPE BHK-22 TYPE BHK-23 50:5 401803-K21 - C10 75:5 401803-K22 - C10 100:5 401803-K23 - C20 150:5 401803-K24 - C20 200:5 401803-K25 B0.2 C50 300:5 401803-K26 B0.2 C50 400:5 401803-K27 B0.9 C100 500:5 401803-K28 B0.9 C100 500:5 401803-K44 B0.9 C100 600:5 401803-K29 B0.9 C100 401805-K07 B1.8 C200 600:5 401803-K41 B0.9 C100 800:5 401803-K30 B0.9 C100 1000:5 401803-K31 B1.8 C100 1200:5 401803-K32 B1.8 C200 401805-K10 B1.8 C200 1200:5 401803-K43 B1.8 C200 1500:5 401803-K33 B1.8 C200 401805-K21* B1.8 C200 2000:5 401803-K19* B1.8 C400 401805-K22* B1.8 C200 2000:5 401803-K34* B1.8 C200 2400:5 401803-K42* B1.8 C200 2500:5 401803-K35* B1.8 C400 401805-K23* B1.8 C200 2500:5 401803-K45* B1.8 C200 3000:5 401803-K51* B1.8 C200 401805-K24* B1.8 C200 3000:5 401803-K16* B1.8 C400 3500:5 401803-K20* B1.8 C400 4000:5 401803-K17* B1.8 C400 401805-K25* B1.8 C200 5000:5 401803-K18* B1.8 C400 401805-K26* B1.8 C400 TYPE BHK-22M MULTI RATIO TYPE BHK-23M 600:5 401810-K21 B1.8 C100 1200:5 401810-K22 B1.8 C200 2000:5 401810-K23 B1.8 C200 401820-K01 B1.8 C200 3000:5 401810-K4 B1.8 C400 401820-K02 B1.8 C200 3000:5 401820-K05 B0.9 C200 4000:5 401810-K5 B1.8 C400 401820-K03 B1.8 C200 5000:5 401810-K6 B1.8 C400 401820-K04 B1.8 C200 *Encapsulated

4B Piedmont Bushings & Insulators, LLC 600 volt - Relaying Type TYPE BHK-22S TYPE BHK-23S 50:5 401812-K1 - C20 - - - 75:5 401812-K2 - C20 - - - 100:5 401812-K3 - C50 - - - 150:5 401812-K4 - C50 - - - 200:5 401812-K5 B0.2 C100 - - - 300:5 401812-K6 B0.2 C100 - - - 400:5 401812-K7 B0.9 C200 - - - 500:5 401812-K8 B0.9 C200 - - - 600:5 401812-K9 B0.9 C200 - - - 800:5 401812-K10 B0.9 C200 - - - 1000:5 401812-K11 B1.8 C200 - - - 1200:5 401812-K12 B1.8 C400 - - - 1500:5 401812-K13 B1.8 C400 401818-K1 B1.8 C400 2000:5 - - - 401818-K2 B1.8 C400 2500:5 401812-K15 B1.8 C800 401818-K3 B1.8 C400 3000:5 401812-K16 B1.8 C800 401818-K4 B1.8 C400 4000:5 401812-K17 B1.8 C800 401818-K5 B1.8 C400 5000:5 401812-K18 B1.8 C800 401818-K6 B1.8 C400 TYPE BHK-22MS MULTI RATIO TYPE BHK-23MS 2000:5 401822-K3 B1.8 C800 401825-K1 B1.8 C400 3000:5 401822-K4 B1.8 C800 401825-K2 B1.8 C400 4000:5 401822-K5 B1.8 C800 401825-K3 B1.8 C400 5000:5 401822-K6 B1.8 C800 401825-K4 B1.8 C400 BG-63 TYPE BG-63 TYPE BG-66S 100:5 402042-K01 - C10 402038-K01 - C20 150:5 402042-K02 - C20 402038-K02 - C50 200:5 402042-K03 - C20 402038-K03 B0.2 C50 250:5 402042-K04 - C20 402038-K04 B0.2 C50 300:5 402042-K05 B0.1 C20 402038-K05 B0.5 C100 400:5 402042-K06 B0.2 C50 402038-K06 B0.5 C100 500:5 402042-K07 B0.2 C50 402038-K07 B0.5 C100 600:5 402042-K08 B0.5 C100 402038-K08 B0.9 C200 800:5 402042-K09 B1.8 C100 402038-K09 B1.8 C200 1000:5 402042-K10 B1.8 C100 402038-K10 B1.8 C200 1200:5 402042-K11 B1.8 C200 402038-K11 B1.8 C400 1500:5 402042-K12 B1.8 C200 402038-K12 B1.8 C400 2000:5 402042-K13 B1.8 C200 402038-K13 B1.8 C400 2500:5 402042-K14 B1.8 C200 402038-K14 B1.8 C400 3000:5 402042-K15 B1.8 C200 402038-K15 B1.8 C800 4000:5 402042-K16 B1.8 C200 402038-K16 B1.8 C800 5000:5 402042-K17 B1.8 C200 402038-K17 B1.8 C800 Multi-ratio available upon request. BG-66S

Piedmont Bushings & Insulators, LLC 600 volt - Metering Type 4B The UM series of current transformers are window type designed primarily for indoor or outdoor metering applications. While they have some relaying capability, it is small, particularly in low ratios. They are encapsulated in polyurethane. The secondary terminals are compression lug type suitable to receive wire sizes between #14-#8 AWG. A clear plastic terminal cover with sealing wire and short circuiting link provision is included. A mounting kit option is available. A variety of window sizes are available from 3 to 8. TYPE UM-3 Primary Burden Window Current Ordering For Relaying Diameter Rating Number 0.3 Acc Accuracy D 50 402546-K01 - - 3.06 100 402546-K02 B0.1 C20 2.5 200 402546-K03 B0.5 C30 2.5 400 402546-K04 B0.5 C30 3.06 500 402546-K05 B0.5 C30 3.06 600 402546-K06 B0.5 C30 3.06 800 402546-K07 B0.5 C30 3.06 1000 402546-K08 B0.5 C30 3.06 1200 402546-K09 B0.5 C30 3.06 200/400 402546-K10 B0.5 C30/C50 2.5 300/600 402546-K11 B0.5 C20/C30 3.06 400/800 402546-K12 B0.5 C20/C50 3.06 150 402546-K13 B0.5 C20 2.5 50/100 402546-K14 B0.5 C20 2.5 100/200 402546-K15 B0.5 C30/C50 2.5 Approximate Weight: 17 lbs TYPE UM-4 Primary Burden Window Current Ordering For Relaying Diameter Rating Number 0.3 Acc Accuracy D 50:5 402647-K01 - C10 3.5 75:5 402647-K02 - C10 3.5 100:5 402647-K03 - C20 3.5 150:5 402647-K04 - C20 3.5 200:5 402647-K05 B0.1 C50 3.5 250:5 402647-K06 B0.2 C50 3.5 300:5 402647-K07 B0.2 C50 3.5 400:5 402647-K08 B0.5 C100 4.0 500:5 402647-K09 B1.8 C100 4.0 600:5 402647-K10 B1.8 C100 4.0 800:5 402647-K11 B1.8 C200 4.0 1000:5 402647-K12 B1.8 C200 4.0 1200:5 402647-K13 B1.8 C200 4.0 1500:5 402647-K14 B1.8 C200 4.0 2000:5 402647-K15 B1.8 C200 4.0 2500:5 402647-K16 B1.8 C200 4.0 3000:5 402647-K17 B1.8 C200 4.0 4000:5 402647-K18 - C200 4.0 Approximate Weight: 35 lbs

4B Piedmont Bushings & Insulators, LLC 600 volt - Metering Type TYPE UM-5 Primary Burden Window Current Ordering For Relaying Diameter Rating Number 0.3 Acc Accuracy D 600 402548-K01 - C30 4.75 800 402548-K02 - C30 4.75 1000 402548-K03 - C50 4.75 1200 402548-K04 - C30 4.75 1500 402548-K05 - C30 4.75 2000 402548-K06 B0.9 C50 4.75 3000 402548-K07 B0.9 C10 4.75 4000 402548-K08 B0.9-4.75 600 402548-K09 - C10 4.75 2000 402548-K09 B0.9 C30 4.75 800 402548-K10 - C20 4.75 1600 402548-K10 B0.9 C30 4.75 1000 402548-K11 - C30 4.75 2000 402548-K11 B0.9 C50 4.75 1500 402548-K12 - - 4.75 3000 402548-K12 B0.9 C10 4.75 2000 402548-K13 B0.9-4.75 4000 402548-K13 B0.9-4.75 Approximate Weight: 65 lbs TYPE UM-8 Primary Burden Window Current Ordering For Relaying Diameter Rating Number 0.3 Acc Accuracy D 2000 402550-K01 B0.9 C50 8.25 3000 402550-K02 B1.8 C100 8.25 4000 402550-K03 B1.8 C100 8.25 5000 402550-K04 B1.8 C100 8.25 6000 402550-K05 B1.8-8.25 8000 402550-K11 B1.8-8.25 1000 402550-K06 B0.5 C30 8.25 2000 - B0.9 C50 8.25 1500 402550-K07 B0.5 C50 8.25 3000 - B1.8 C100 8.25 2000 402550-K08 B0.9 C50 8.25 4000 - B1.8 C100 8.25 2500 402550-K09 B1.8 C100 8.25 5000 - B1.8 C200 8.25 3000 402550-K10 B1.8-8.25 6000 - B1.8-8.25 4000 402550-K12 B1.8-8.25 5000 - B1.8-8.25 Approximate Weight: 65 lbs

Piedmont Bushings & Insulators, LLC 5Kv - 15Kv - Relaying type 4B The 5Kv and 15Kv MC series of current transformers are bar type designed to be bus mounted and are suitable for relaying and metering applications. Most are available as either single or multi ratio type. They can be supplied with silver plated aluminum bars as standard or copper when requested. The core and coils are potted in an epoxy case with polyurethane. The secondary terminals consist of a 10-32 insert in the molding. A 10-32 x 3/8 binding head screw is recommended. 5Kv TYPE MC-5 & MC-5M Primary Burden Current Ordering For Relaying Rating Number 0.3 Acc Accuracy 75:5 401437-K1 - C10 100:5 401437-K2 - C10 150:5 401437-K3 B0.1 C20 200:5 401437-K4 B0.1 C20 250:5 401437-K15 B0.2 C20 300:5 401437-K05 B0.5 C50 400:5 401437-K06 B0.5 C50 500:5 401437-K16 B0.9 C50 600:5 401437-K07 B0.9 C100 800:5 401437-K08 B1.8 C100 1000:5 401437-K17 B1.8 C100 1200:5 401437-K18 B1.8 C200 1500:5 401437-K10 B1.8 C200 2000:5 401437-K11 B1.8 C200 2500:5 401437-K12 B1.8 C200 3000:5 401437-K13 B1.8 C200 4000:5 401437-K14 B1.8 C200 MULTI RATIO 600:5 401434-K1 B1.8 C400 1200:5 401434-K2 B1.8 C100 2000:5 401434-K3 B1.8 C200 3000:5 401434-K4 B1.8 C200 4000:5 401434-K5 B1.8 C200 Approximate Weight: 16 lbs 5Kv 15Kv TYPE MC-25A TYPE MC-15A 75:5 401574-K1 - C10 401160-T1 - C10 100:5 401574-K2 - C10 401160-T2 - C10 150:5 401574-K3 B0.1 C20 401160-T3 B0.1 C20 200:5 401574-K4 B0.1 C20 401160-T4 B0.1 C20 250:5 401574-K5 B0.5 C20 401160-T5 B0.5 C20 300:5 401574-K6 B0.5 C50 401160-T6 B0.5 C20 400:5 401574-K7 B0.5 C50 401160-T7 B0.5 C50 500:5 401574-K8 B0.9 C50 401160-T8 B0.9 C50 600:5 401574-K9 B1.8 C100 401160-T9 B1.8 C50 800:5 401574-K10 B1.8 C100 401160-T10 B1.8 C100 1000:5 401574-K11 B1.8 C100 401160-T11 B1.8 C100 1200:5 401574-K18 B1.8 C200 401160-T18 B1.8 C100 1500:5 401574-K13 B1.8 C200 401160-T13 B1.8 C200 2000:5 401574-K14 B1.8 C200 401160-T14 B1.8 C200 2500:5 401574-K15 B1.8 C200 401160-T15 B1.8 C200 3000:5 401574-K16 B1.8 C200 401160-T16 B1.8 C200 4000:5 401574-K17 B1.8 C200 401160-T17 B1.8 C200 TYPE MC-25M1 MULTI RATIO TYPE MC-15M1 600:5 401577-K1 B0.9 C400 401161-T1 B0.9 C100 1200:5 401577-K2 B1.8 C100 401161-T2 B1.8 C100 2000:5 401577-K3 B1.8 C200 401161-T3 B1.8 C200 3000:5 401577-K4 B1.8 C200 401161-T4 B1.8 C200 4000:5 401577-K5 B1.8 C200 401161-T5 B1.8 C200 Approximate Weight: 16 lbs

4B Piedmont Bushings & Insulators, LLC 5Kv - 15Kv - Relaying Type 5Kv 15Kv TYPE MCS-25 TYPE MC-21S 50:5 401572-K01 - C20 401153-01 - C20 75:5 401572-K02 - C20 401153-02 - C20 100:5 401572-K03 - C50 401153-03 - C50 150:5 401572-K04 B0.2 C50 401153-04 B0.2 C50 200:5 401572-K05 B0.2 C50 401153-05 B0.2 C50 300:5 401572-K06 B0.5 C50 401153-06 B0.5 C50 400:5 401572-K07 B0.9 C100 401153-07 B0.9 C100 Approximate Weight: 25 lbs 5Kv 15Kv TYPE MCB-5A TYPE MCB-15A 1200:5 401024-T1 B1.8 C200 401024-T9 B1.8 C200 1500:5 401024-T2 B1.8 C200 401024-T10 B1.8 C200 2000:5 401024-T3 B1.8 C400 401024-T11 B1.8 C400 2500:5 401024-T4 B1.8 C400 401024-T12 B1.8 C400 3000:5 401024-T5 B1.8 C400 401024-T13 B1.8 C400 4000:5 401024-T6 B1.8 C400 401024-T14 B1.8 C400 5000:5 401024-T7 B1.8 C400 401024-T15 B1.8 C400 TYPE MCB-5M MULTI RATIO TYPE MCB-15M 3000:5 401040-T1 B1.8 C400 401040-T5 B1.8 C400 4000:5 401040-T2 B1.8 C400 401040-T6 B1.8 C400 5000:5 401040-T3 B1.8 C400 401040-T7 B1.8 C400 15Kv TYPE MCR-15A1 TYPE MCR 15M1 MULTI RATIO 600:5 401514-T20CU B0.9 C200 401479-T14CU B0.9 C200 600:5 401514-T08AL B0.9 C200 401479-T14AL B0.9 C200 800:5 401514-T01CU B1.8 C200 - - - 800:5 401514-T09AL B1.8 C200 - - - 1200:5 401514-T02CU B1.8 C400 401479-T15CU B1.8 C400 1200:5 401514-T10AL B1.8 C400 401479-T15AL B1.8 C400 1500:5 401514-T11 B1.8 C400 - - - 2000:5 401514-T12 B1.8 C400 401479-T10 B1.8 C400 2500:5 401514-T13 B1.8 C400 - - - 3000:5 401514-T14 B1.8 C400 401479-T11 B1.8 C400 4000:5 401514-T15 B1.8 C400 401479-T12 B1.8 C400 5000:5 401514-T16 B1.8 C400 - - -

Piedmont Bushings & Insulators, LLC 600 volt - Metering Type Additional Products In addition to conventional current transformers Piedmont make zero sequence current transformers, sensors used with static relays, and linear couplers. Zero sequence transformers are a standard transformer with a very large magnetic core and a low ratio such as 50:5 amperes. When all three phases are pulled through the transformer window and the current in each phase is equal the magnetic fields cancel and there is no output. Under ground fault conditions the currents are unbalanced and an output exists that can operate a relay. Current sensors are constructed like a current transformer but have much smaller magnetic circuits and produce a voltage output that can operate low burden static relays. There are no industry standards of output so they are designed to complement specific relay characteristics. For distribution circuits up to 69Kv Piedmont offers current and voltage sensors in the form of an outdoor post insulator. Ask for Catalog 3B. For over forty years, PDC has been manufacturing high quality, very reliable dielectric products in the Factory located in Woodruff, South Carolina, having affiliations with ITE and ABB. Besides CRC bushings, other dielectric products include: PBI Commitment Polykeram insulators Line sensors Instrument transformers For more details and technical assistance on these dielectric products, contact the Factory. PBI is committed to becoming a dominant supplier of capacitance-graded bushings to transformer manufacturers for new equipment and to end-users for replacement requirements. For more details and technical assistance on CRC bushings, contact the Factory, or first, visit us on-line at pb-i.com at any time of the day to obtain: an indepth presentation catalog and prints as well as, to order CRC bushings from our on-line catalog using our secure shopping cart ordering system. Linear couplers are constructed like a current transformer, but with a nonmagnetic core so they do not saturate. They have a significant number of turns that produce a standardized output of 5 volts per 1000 amperes. Since they do not have the power capability of a current transformer they are very sensitive and great care must be used in their construction and calibration. We can help you with applications of any these devices. Please call, fax, or e-mail your requirements and we will respond promptly. 251 Harris Bridge Road Post Office Box 849 Woodruff, South Carolina 29388 Phone: 864-476-6360 Fax: 864-476-6376 www.pb-i.com