LIB 510 MV Process Operator s Manual

Similar documents
LIB 500 Event List Operator s Manual

LIB 500 Base & LIB 510 Introduction Operator s Manual

LIB 510 Measurement Reports 2 Operator s Manual

Distribution Management System Open++ Opera v.3.2. User Manual

Distribution Management System Open++ Opera v.3.3. User Manual

MicroSCADA Pro LIB 510 *4.1. Operation Manual

MicroSCADA Pro SYS

User s Manual LIB 580*4.0.2 MS-Process*1.5

MicroSCADA Pro SYS Operation Manual

SMS 510, CAP 505 LON Gateways Configuration Configuration Guide

MV Process Application Library LIB 510. Product Guide

SYS 500 Visual SCIL User Interface Design

MicroSCADA Pro DMS 600 *4.0. Operation Manual

MicroSCADA Pro SYS Operation Manual

MicroSCADA Pro DMS Operation Manual

MicroSCADA Pro DMS 600 *4.1. Operation Manual

MicroSCADA Status Codes

SYS MRS MEN Issued: Version: A Program revision: Visual SCIL Objects. Notice 1. Notice 2. Notice 3.

Relay Setting Tools CAP 501 Operator s Manual

Connectivity Packages. User's Guide - ANSI Version

CAP 505. User s Guide

MicroSCADA Pro SYS

Power Products. Protection and Control IED Manager PCM600 Product Guide

OPERATION MANUAL. MV-410HS Layout Editor. Version higher. Command

Relay Product Engineering Tools

SCADA SYSTEM FOR PEDEEE SYRIA PROJECT

General characteristics of C-type relay modules

Busbar protection REB 670

Relay configuration and setting tool package

Contents. Drive View 7

MicroSCADA Pro SYS Historian Operation

SIMATIC. Process Control System PCS 7 OS Process Control (V8.1) Preface 1. Additional documentation 2. Functions of the PCS 7 OS in process mode 3

MicroSCADA Pro DMS 600 *4.1 System Overview. Technical Description

CAP 505 Relay Product Engineering Tools Installation and Commissioning Guide

Deckblatt. APL Operator Guide SIMATIC PCS 7. Application description June Applikationen & Tools. Answers for industry.

SIMATIC. Process Control PCS 7 V7.0 PCS 7 OS Process Control. Preface, Contents. Additional Documentation 1 Functions of the PCS 7 OS in Process Mode

Communication 7. What's in this Chapter? This chapter contains the following sections:

INSTRUCTION MANUAL. Web server description. AQ 300 Series

User Manual. AQ-F215 Simulator

MicroSCADA Programming Language SCIL

Copyright 2015 Integrated Environmental Solutions Limited. All rights reserved.

MP240 / MP245 MP260 / MP268 MP480 / MP486 SIMPLIFIED SERVICE MANUAL

ADVANCED DRIVER PROGRAMMING. EVERset User Manual

SIMATIC. Process Control System PCS 7 OS Process Control (V8.1) Security information 1. Preface 2. Additional documentation 3

How-To Guide. LCD 1x5 Code Creation Assistant. Copyright Topaz Systems Inc. All rights reserved.

Océ CPS700. Job manual

COM600 series 5.0 Operator's Manual

A warning provides additional information which, if ignored, may result in a risk of personal injury.

NORDSON CORPORATION AMHERST, OHIO USA

Lecture 6 Substation Automation Systems

GENIEEVO Range. Protection and Control Module P4. Unit Protection Cable Feeder. Functional Description. Issue A1

COM600 Station Automation Series External OPC Client Access 3.1. User's Guide

Mobile Connect for USA Mobility Pagers for BlackBerry

Making the Gradient. Create a Linear Gradient Swatch. Follow these instructions to complete the Making the Gradient assignment:

A PC, preferably at least a Pentium 166 with > 8 M memory and running Windows 3.1, Windows 95 or Windows NT.

COM600 Station Automation Series MNS is Connectivity (OPC) 3.2. User's Guide

Contents. Batch & Import Guide. Batch Overview 2. Import 157. Batch and Import: The Big Picture 2 Batch Configuration 11 Batch Entry 131

Tabular Building Template Manager (BTM)

Overcurrent and Earth-Fault Relay REJ 525. Technical Reference Manual

PRINTER DRIVER GUIDE (KODAK 305 Photo Printer)

Introduction. CHAPTER 3 Working in the SAS Windowing Environment

Equitrac Integrated for Konica Minolta

Protection System Simulator SIM600. Installation Manual

DriveWizard Plus Instruction Manual

Online Submission Tool: Packet Management

MicroSCADA Pro COM 500 *4.1. User s Guide

SECTION 5 HSLRT6 WINDOWS BASED SETUP PROGRAM REFERENCE

Integrated Cloud Environment Bates Stamping User s Guide

Earth-fault Relay SPAJ 110 C. Product Guide

PLC 24 FERRIC CHLORIDE AND POLYMER SYSTEM SCADA SYSTEM OPERATION MANUAL. Revision 1.0 May 3, 2006

MicroSCADA Pro DMS System Administration

Jussi Ahola, ABB Oy A self healing power system for the accurate fault location and zone concept T&D Smart Grids Europe 2012

SYS 500 System Management

CHAPTER Wi r i n g NOTICE:

ekorsoft CONFIGURATION SOFTWARE FOR PROTECTION AND INTEGRATED CONTROL UNITS

Forms Desktop for Windows Version 4 Manual

PLC 4 PRIMARY SEDIMENTATION SYSTEM SCADA SYSTEM OPERATION MANUAL. Revision 1.0 May 15, 2006

4) Verify that the Color Type text box displays Process and that the Color Mode text box displays CMYK.

For DX100 for Industrial Robot MOTOMAN Ladder Editing Software for Personal Computers Ladder Editor 32 for DX100 Operator s Manual

Service Calibrations 5

Commander User Manual Version 1.1

PduSetup User Manual. Professional Electronics for Automotive and Motorsport

NEC ESMPRO AlertManager User's Guide

STCP 04-3 Issue 005 Real Time Data Provision

Batch and Import Guide

750/760 Local/Remote Control without using the Faceplate Pushbuttons

PLC 23 DUAL MEDIA FILTERS 5 AND 6 SCADA SYSTEM OPERATION MANUAL. Revision 1.0 April 18, 2006

Océ DS10. Operator s manual

Relion 615 series Line Differential Protection and Control RED615 Ver. 2.0 Technical Presentation

Importing HDL Files with Platform Manager 2

User's Guide. For CarChip and CarChip E/X 8210 & 8220

Programmable Serial Interface Card Driver Bell-Ennium 7785-P2005 Magnetic Plate Stirrer

EMP Monitor Operation Guide V4.30

Chapter 2 Introduction to the Web Browser Interface

New Features in Designer 5.05/UniOP 4.20

Forms for Palm OS Version 4 Manual

Phone: Fax: Web: -

Viewing Reports in Vista. Version: 7.3

FA-B30 Version 1.0 Basic Label Printing Software

7SR21 Non-Directional 7SR22 Directional Overcurrent Relay

Transcription:

1MRS751388-MUM Issue date: 31.01.2000 Program revision: 4.0.3 Documentation version: A LIB 510 Copyright 2000 ABB Substation Automation Oy All rights reserved. Notice 1 The information in this document is subject to change without notice and should not be construed as a commitment by ABB. ABB assumes no responsibility for any error that may occur in this document. Notice 2 This document complies with the program revision v. 2.4. Notice 3 Additional information such as Release Notes and Last Minute Remarks can be found on the program distribution media. Trademarks Microsoft is a registered trademark of Microsoft Corporation. Windows NT is a trademark of Microsoft Corporation. LONWORKS is registered trademark of Echelon Corporation. Other brand or product names are trademarks or registered trademarks of their respective holders. All Microsoft products referenced in this document are either trademarks or registered trademarks of Microsoft Corporation.

1MRS751388-MUM LIB 510 Contents Page 1 General...5 1.1 Station/Process Picture... 5 1.1.1Picture Specific Functions... 5 1.2 Graphical Representations and... 6 1.2.1Switching Devices Status Indication... 6 1.2.2Color Coding & Suffixes... 6 1.2.3Color definitions... 7 1.2.4Switching devices status indication... 8 1.2.5Selection... 8 1.3 Controlling Switching Devices... 8 1.3.1Main Control Dialog, Circuit Breaker... 8 1.4 Common functions... 11 1.4.1Alarm state dialog... 11 1.4.2Blockings dialog... 12 1.4.3Object messages dialog... 13 1.4.4Normal state settings dialog... 14 1.4.5Operation countings dialog... 15 1.4.6Position simulation dialog... 16 ABB Automation 3

1MRS751388-MUM LIB 510 1 General 1 General This chapter describes the most common processes seen from the library implementations in LIB 500 BASE and LIB 510 v. 4.0.3. 1.1 Station/Process Picture 1.1.1 Picture Specific Functions A process picture is located in the picture specific area and consists of the picture functions installed. The medium voltage process objects are typical example of picture specific functions. Picture specific functions are activated during run mode: by clicking on the representation symbol by the mouse and selecting the wanted function. Figure 1. Some picture functions in the MV process ABB Automation 5

LIB 510 1 General 1MRS751388-MUM Number Picture function Remarks 1 Station Local/Remote Can be configured to be invisible, then the Local/Remote indication is shown in the header, see the picture header overview in the introduction chapter. 2 Bay Local/Remote - 3 Disconnector Other symbols can be used. 4 Circuit breaker Other symbols can be used. 5 Relay symbol Several functions can be activated, that is depending on the device behind the symbol. 6 Measuring functions The measurings can be presented in different ways (preconfigured). 7 Earth switch Other symbols can be used. 8 Trip tag A trip tag shows the reason for tripping, like overcurrent, earth fault current etc. An auto reclosing tag is also available. 9 Transformer Other symbols can be used. Various kinds of dialogs are opened when clicking, e.g. on the picture functions in the Bay. These dialogs do often also contain subdialogs. Both dialogs and subdialogs contain a help function, giving further assistance, if needed. The procedure for handling a function in an operation dialog is just to click on the function to be executed. A request to verify the operation is given, before executing, otherwise the user cannot regret the operation. The object messages are giving actual information and status regarding the object, e.g. in figure x the object is a circuit breaker that is not connected to the process. 1.2 Graphical Representations and Some principles are general and used for all MV functions (symbols and colors etc.). A description of these general principles is given in this section. 1.2.1 Switching Devices Status Indication The status presentation for an object consists of three parts: a representation symbol, a color and a suffix. These three define the exact object status. The relationship between color and suffix indication can be defined in the Application Settings. Either color or suffix or even both of them can be selected for status indication. 1.2.2 Color Coding & Suffixes The current state is indicated by different symbols. The color or/and suffix of the symbol gives additional information on the object. 6 ABB Automation

1MRS751388-MUM LIB 510 1 General Color Suffix Status GREEN * Normal state GREEN (TI)** Time invalid CYAN ME Manually entered YELLOW WA Warning for Analog inputs YELLOW IB Alarm, event, printouts and/or reprocessing blocked BROWN CB Control blocked RED AL Alarm, acknowledged RED, blinking AL Alarm, unacknowledged MAGENTA IV Invalid MAGENTA BL Update blocked, external DARK BLUE SE External substitution MAGENTA NU Not updated (OS=4..9) MAGENTA NU Not updated (OS=2) MAGENTA NS Not sampled (OS=10) MAGENTA BL Update blocked, internal DARK BLUE SI Internal substitution WHITE *** Selected on monitor WHITE, blinking *** Selected, under command *Suffix is not shown **As default suffix is not shown ***No separate suffix. The suffix indicating the state before selection will remain. 1.2.3 Color definitions The colors used in LIB 510 refers to the following System colors (M scope). The colors can be changed by using the Color Settings tool that is being opened from the System Configuration folder in the Tool Manager. Color GREEN CYAN YELLOW BROWN RED MAGENTA DARK BLUE WHITE BLACK Color definition Normal, dynamics ( M,32) Manually entered ( M,29) Warning ( M,17) Control blocked ( M,28) Alarm ( M,16) Not updated ( M,30) Substituted ( M,38) Selected object ( M,27) Foreground, normal ( M,14) ABB Automation 7

LIB 510 1 General 1MRS751388-MUM 1.2.4 Switching devices status indication Different colors and symbols are used to indicate the status of the objects. Circuit breaker and disconnector The symbols below are the symbols that are used as standard symbols. The symbols to the left are for circuit breakers and the ones to the right for disconnectors. Symbols State Circuit breaker Disconnector close open intermediate position (0,0) faulty position (1,1) not sampled Figure 2. Examples of the different symbols for circuit breaker and disconnector 1.2.5 Selection Selectable objects are highlighted according to motif standard. There are no hidden functions. Please note that selectable is not equal to controllable. Clicking on a selectable object will bring up the main dialog from which other actions can be initiated. By default only one object can be selected per MicroSCADA screen; selecting another object will cancel the previous selection. 1.3 Controlling Switching Devices 1.3.1 Main Control Dialog, Circuit Breaker The circuit breaker main control dialog is aimed for monitoring and controlling the circuit breaker. 8 ABB Automation

1MRS751388-MUM LIB 510 1 General Operations can be made if the circuit breaker is motorised (i.e. remotely controllable), the operators authorisation level is Control (1) or higher, the circuit breaker state allows controls, and if there are no active blockings. If operations are allowed, the button Open breaker or Close breaker will respectively be active. The main control dialog shows messages of the circuit breaker status on the information bar. Only the most important message is shown, but all active messages can be seen in the Object messages dialog by selecting it under the More... button. Active messages can be seen in the Object messages dialog and more detailed explanations of their meaning can be found in Help. When the option Open breaker or Close breaker is selected, the selection command is sent to the control unit. Before the operation is carried out, the user has to verify the operation in the confirmation dialog. In case there are errors e.g. in the communication, a SCIL status code is shown. The actual meaning of the code can be found in the Status Codes Manual (1MRS751251-MEN). If the circuit breaker objects are not connected to the process, the dialog simulates the actual operation within database. Other supported features are accessible by the More... button. Help on each subdialog is found by clicking the sub-dialogs Help button. Figure 3 presents the main control dialog for circuit breaker which is opened from the picture function. Figure 3. The main control dialog for the circuit breaker The object identification text (OI) of the selected circuit breaker is shown on the upper part of the dialog. ABB Automation 9

LIB 510 1 General 1MRS751388-MUM Table 1 The dialog buttons have the following functionality: Button Open breaker Close breaker More Cancel Help When the circuit breaker is connected to the process, this button sends an open selection command to the control unit and the control action acknowledgement will be displayed, see Figure 4. If there is no connection to the process, this dialog simulates the control selection. When the circuit breaker is connected to the process, this button sends a close selection command to the control unit and the control action acknowledgement dialog will be displayed, see Figure 4. If there is no connection to the process, this dialog simulates the control selection. Opens a selection list of the circuit breaker sub-functionality. Closes the dialog and its sub-dialogs. Opens the help dialog. Control Confirmation Dialog Figure 4 presents the control confirmation dialog which is opened from the main control dialog of the circuit breaker. The function of this dialog is to confirm the selected action before executing it i.e. performing the second step of the secured control. Figure 4. Circuit breaker control confirmation dialog On the basis of the question in the dialog it is possible to verify that the right action is to be executed. Table 2 The dialog buttons have the following functionality: Button Execute Cancel Executes the selected command. In case of a simulated process, the change in the database is simulated. Deselects the object and closes the dialog. 10 ABB Automation

1MRS751388-MUM LIB 510 1 General 1.4 Common functions This chapter gives a description of the functions that are common to most of the standard functions in the software package. The functions that are individual or available for only a few standard functions within the are described in connection to the corresponding standard function. In this common function section, the switching device will be used as an example function, but the principle is the same for all standard functions. 1.4.1 Alarm state dialog The alarm state dialog can be opened by selecting Alarm state... which can be found by clicking the More button in the main control dialog. The dialog presents all persisting or fleeting alarms for the device, bay or substation depending on the selected standard function, and the unacknowledged alarms can be acknowledged. The persisting and fleeting alarms can be seen in a combo-box. If there are no alarms, the combo-box does not contain any text. In case there is one alarm, the object identifier is shown in the combo-box. If there are more than one alarm, the text Acknowledge all is shown in the combo-box by default. In that case all existing alarms can be viewed by scrolling the combo-box up and down. The currently selected alarm can be acknowledged by pressing the Acknowledge alarm button. The button is active, if an unacknowledged alarm is present and the authorization level of the operator is Control (1) or higher. Figure 2 presents the switching device alarm state dialog. Figure 5. Switching device alarm state dialog (FPU_SSWD.PIC) The alarm state of the selected process object is shown on the upper part of the dialog. The buttons have the following functionality: ABB Automation 11

LIB 510 1 General 1MRS751388-MUM Button Acknowledge Alarm Close Help Sets the alarm receipt status to acknowledged. Closes the dialog. Opens the general LIB 510 help dialog with the help text file FPU_SSWD.HLP. 1.4.2 Blockings dialog The blocking dialog can be opened by selecting Blockings... which can be found by clicking the More button in the main control dialog. Depending on the selected standard function, the blockings dialog is used for making the following blockings within the selected device, bay or substation in MicroSCADA/SCS database: Blocking Update Control Alarm Event Printout Reprocessing Function The indications are not updated from the process. Operation commands are not sent to the process. Alarms are not activated, regardless of the object state. Event registrations are not made. The events are not shown in event list. Events are not sent to the printer. Event channel activation is blocked, i.e. no event driven execution of tasks has been performed. The current blocking state for the selected switching device can be seen in the position of the toggle buttons (a down pressed button means that the selection in question is active). There are three cases where both toggle buttons for blocking can be unset. There is a discrepancy in the database, i.e. some process object(s) are blocked but not all. It is not possible to perform the blocking. This results from the signal settings, e.g. the printer is not defined for the signal(s). In this case the text identifying the blocking is written in grey color. There are no signals found to be blocked/deblocked. The reason may be that no process database is created for the object or there is a configuration error. This situation is also indicated by an information message. Operations can be made, if the authorization level of the operator is Control (1) or higher. The user can set the wanted blocking state with the help of the toggle buttons. When OK is selected, the actual blockings are made and the dialog is closed. If Cancel is selected, the blocking selections are ignored and the dialog is closed. 12 ABB Automation

1MRS751388-MUM LIB 510 1 General Figure 3 presents the switching device blocking dialog. Figure 6. Switching device blocking dialog (FPU_SSWF.PIC) Table 3 The buttons have the following functionality: Button Toggle buttons OK Cancel Help Set/reset the corresponding blocking. When the dialog is opened, these buttons are set to indicate the current blocking state of the switching device. In case of not motorized switching device, the Control blocking toggle buttons are set insensitive. If there is discrepancy in the database (i.e. some process objects have different blocking state compered to others), neither block nor deblock is set. Sets the selected blockings to the database and closes the dialog. Discards all changes made and closes the dialog. Opens the general LIB 510 help dialog with the help text file FPU_SSWF.HLP. 1.4.3 Object messages dialog The object messages dialog is opened by selecting Object messages... which can be found by clicking the More button in the main dialog. An overall picture of the standard function state can be seen in the dialog. The dialog shows information messages active at the moment the dialog is opened. The most important active message is also shown in the information bar of the main dialog. ABB Automation 13

LIB 510 1 General 1MRS751388-MUM A new "snapshot" can be taken by pressing Refresh. The dialog can be closed by pressing Close. If messages do not fit into one view, they can be viewed with the scrollbar. Information messages The object messages are listed under the corresponding Object messages section in each standard function. Figure 4 presents the switching device object messages dialog. Figure 7. Switching device object messages dialog (FPU_SSWJ.PIC) Table 4 The buttons have the following functionality: Button Refresh Close Help Takes a "snapshot" of the current object state. Closes the dialog. Opens the general LIB 510 help dialog with the help text file FPU_SSWJ.HLP. 1.4.4 Normal state settings dialog The normal state settings dialog can be opened by selecting State settings... which can be found by clicking the More button in the main control dialog. The normal value has a meaning only, if all spontaneous object state changes are defined to activate an alarm (when the LA attribute value of the indication object is 15). 14 ABB Automation

1MRS751388-MUM LIB 510 1 General The value of the normal state is checked at system start-up. If the state of an object at start-up is not equal to the normal state, an alarm is activated. If a normal state is not defined, no alarm is activated at start-up regardless of the object state. Operations can be made, if the authorization level of the operator is Control (1) or higher. The normal state can be selected by choosing the correct alternative from the list. Selection can be saved by pressing OK and cancelled by pressing Cancel. Figure 5 presents the switching device normal state settings dialog. Figure 8. Switching device normal state settings dialog (FPU_SSWG.PIC) Table 5 The buttons have the following functionality: Button Selector OK Cancel Help Selects the normal state of the switching device. When the dialog is opened, the selector shows the current normal state. Sets the selected normal state to the database and closes the dialog. Closes the dialog. Opens the general LIB 510 help dialog with the help text file FPU_SSWG.HLP. 1.4.5 Operation countings dialog The operation countings dialog can be opened by selecting Operation countings... which can be found by clicking the More button in the main control dialog. The operation countings counts the number of switch state changes. The counter is increased with one every time the switch is closed or earthed (which means that the indication object in MicroSCADA database receives value 1). ABB Automation 15

LIB 510 1 General 1MRS751388-MUM Operations can be made, if the authorization level of the operator is Control (1) or higher. The counting is set in use with the Counter in use button. The current counter value is shown in the Counter value field. The counter limit can be edited in the Counter limit field. Settings can be saved by pressing OK. The counter can be reset by pressing Reset Counter. Figure 6 presents the switching device operation countings dialog. Figure 9. Switching device operation countings dialog (FPU_SSWI.PIC) Table 6 The buttons have the following functionality: Button Toggle button Counter in use Reset Counter OK Help Activate/Deactivate operation counting. When the dialog is opened, the toggle button shows the current state of operation countings. Resets the counter value to zero. Sets the selected state of operation countings to the database and closes the dialog. Opens the general LIB 510 help dialog with the help text file FPU_SSWI.HLP. 1.4.6 Position simulation dialog The position simulation dialog can be opened by selecting Simulation... which can be found by clicking the More button in the main control dialog. During some communication problems or field device failure, the position of the switch is not automatically known by the system. This dialog has been designed for operators to maintain the consistency of the database in case of an abnormal situation. 16 ABB Automation

1MRS751388-MUM LIB 510 1 General Operation mode The current operation mode can be seen in the position of the Simulation toggle buttons (a down pressed button means that the selection in question is active). Simulation ON means that the position indication is not connected to the process and therefore, it has to be updated manually by the operator. Simulation OFF means that position indication is connected to the process and it is updated automatically by the system. In case of neither ON nor OFF has been pressed down, the position indication has been set out of use (a special switch state setting done by the system engineer). The operation mode can be changed, if the authorization level of the operator is Engineering (2) or higher. The user can set the wanted operation mode with the help of the toggle buttons. When the OK button is selected, the actual setting for the operation mode is made and the dialog is closed. If Cancel is selected, all selections within the dialog, including operation mode selections, are ignored and the dialog is closed. If the position indication does not have any interface to the process, i.e. no station number or address, simulation cannot be set OFF. Position setting The current position of the switch can be seen in the Position toggle buttons. In case of none of the toggle buttons has been pressed down, the position indication is somehow not acceptable or it is not updated, i.e. it is not sampled. The position of the switch can be changed, if the simulation is ON and the operator s authorization level is Operation (1) or higher. The user can set the wanted position with the help of the toggle buttons. When the OK button is selected, the actual setting for the position is made and the dialog is closed. If Cancel is selected, all selections within the dialog, including position settings, are ignored and the dialog is closed. If simulation is not ON, the toggle buttons for the position settings have been dimmed. Figure 7 presents the switching device position simulation dialog. ABB Automation 17

LIB 510 1 General 1MRS751388-MUM Figure 10. Switching device position simulation dialog (FPU_SSWK.PIC) Table 7 The buttons have the following functionality: Button Toggle buttons for simulation setting Toggle buttons for position setting OK Cancel Help Shows the current operation mode of simulation and can be used to set the position simulation ON or OFF. If there is no process interface defined in the database, the simulation cannot be set in OFF mode. Shows the current position of the switch and can be used to set the wanted position if the simulation mode is ON. Sets the selected state of position simulation to the database and closes the dialog. Discards all changes made and closes the dialog. Opens the general LIB 510 help dialog with the help text file FPU_SSWK.HLP. 18 ABB Automation