RC001-NMS1 (REV.C) User Manual

Similar documents
RC NMS1 (REV.B) User Manual. Beijing Raisecom Science & Technology Co., Ltd

RC3000E Commands Notebook

ISCOM4300 Configuration Guide

Nortel Secure Router 2330/4134 Commissioning. Release: 10.2 Document Revision: NN

RAISECOM RC551 Command Notebook

ISCOM 2126 Series Switch Command Notebook

24-Port 100/1000X SFP + 4-Port 10G SFP+ Managed. Metro Ethernet Switch MGSW-28240F. Quick Installation Guide

24-Port Gigabit with 4 Optional 10G Slots. Layer 3 Managed Stackable Switch XGS / XGS Quick Installation Guide

Table of Contents 1 Basic Configuration Commands 1-1

RC552-FE (A) User Manual

User Manual FMUX01(A) SNMP Upgrade Procedure

RC581 Configuration User Manual

Configuring Host Router and Cisco Analog Video Gateway Module Interfaces

User Manual FRM301 SNMP Upgrade Procedure

VERTICAL HORIZON VH-2402S FAST ETHERNET SWITCH MANAGEMENT GUIDE

User s Manual. Management Converter Chassis. Model No.: SP1386 / SP1387. World Wide Web: ;

16-SLOT IN-BAND MANAGEMENT CHASSIS

Command Line Interface

Raisecom ROS-LITE RC581series Ethernet Media Converter Software Command User Manual Raisecom ROS 3.0 Apr

Configuring the Management Interface and Security

24-Port Gigabit with 4 Optional 10G Slots. Layer 3 Managed Stackable Switch XGS Quick Installation Guide

16/24-Port 10/100/1000T 802.3at PoE + 2-Port 100/1000X SFP Managed Switch GS P2S GS P2S. Quick Installation Guide

Industrial Serial Device Server

48-Port 10/100/1000Base-T with 4 Shared SFP. Managed Gigabit Switch WGSW Quick Installation Guide

Index. B Boot software 5-2 Bridging architecture 7-6 Broadcast filter 8-55 limiting 8-22 Buffer port 7-9 Syslog 8-17, 8-20

24-Port Gigabit + 4-Port 10G SFP+ Slot. Layer 3 Stackable Managed Switch XGS Quick Installation Guide

Command Guide of WGSW-28040

L2+ Managed Gigabit Switch WGSW series

Document Name: User Manual for SC10MK, Modbus RTU to Modbus TCP Converter

L2+ Managed Gigabit/10 Gigabit Ethernet Switch GS-5220 Series

28-Port 10/100/1000Mbps with. 4 Shared SFP Managed Gigabit Switch WGSW / WGSW-28040P. Quick Installation Guide

RC315/316-FE (Rev. A) 10/100M Auto-negotiation Copper-to-Fiber Media Converter. User Manual. Raisecom Technology Co., Ltd.

TL-SG2216/TL-SG2424 Gigabit Smart Switch

Chassis-based Media Converters

FVT Slot Managed Converter Chassis w/ Redundant Power Supply User Manual

Management Software AT-S79. User s Guide. For use with the AT-GS950/16 and AT-GS950/24 Smart Switches. Version Rev.

L2+ Managed LCD Switch GS T2XV(R) / GS T4XV(R) Quick Installation Guide

C H A P T E R Commands Cisco SFS Product Family Command Reference OL

L2+ Managed PoE Switch GS-5220 PoE Series

Command Line Interface Reference Guide Release 2.3.0

MCF2xxx SERIES Multi-channel Modular Media Chassis

Hotwire DSL Access System Student Guide MCP Card. GranDSLAM & MCP Card. Revision Paradyne Corporation Page 1

ROCKETLINX ES8508 ES8508 ES8508F ES8508-XT ES8508F-XT QUICK INSTALLATION GUIDE

L2/L4 Managed Gigabit Ethernet Switch GS-4210 Ultra PoE Series

Configuring for the First Time

DMC SNMP Module for Chassis-Based Media Converter Manual. Rev. 01 (JUN. 2002) 1907MCB RECYCLABLE

No Service Password-Recovery

Network Management Card. User Manual

Management Software AT-S70. User s Guide. CONVERTEON Media Converter Products. Version Rev. B

L2+ Managed Metro Ethernet Switch MGSW / MGSD Series

User Manual. RC511/RC512 Series SNMP Manageable, Bandwidth Control, 10/100 Mbps Auto-Sensing Ethernet Copper to Fiber Media Converter

GE-DSH-73/82 and 82-POE Managed Switch Installation Sheet

Table of Contents 1 Basic Configuration Commands 1-1

16/24/48-Port 10/100/1000T + 2/4-Port 100/1000X SFP Managed Switch GS T2S/GS T2S/GS T4S. Quick Installation Guide

48-Port 10/100Mbps + 4 Gigabit TP / 2 SFP. Managed Switch WGSW Quick Installation Guide

Cajun P333R. Quick Start Guide. Unpack 1. Rack mount (optional) 2. Power up 3. Connect the cables 4. Configure 5. Run Web-based Manager (optional)

Getting Started with the VG248

TFC-1600MM Media Conversion System. Management Configuring Guide

AT-S73, AT-S99 and AT-S102 Version Management Software for the Converteon Media Converter Products. Software Release Notes

for Hardware Installation: IG550 Integrated Gateway

Table of Contents 1 Basic Configuration Commands 1-1

H3C Intrusion Prevention System. Command Reference. Hangzhou H3C Technologies Co., Ltd. Document Version: 5PW

RC701/RC702-FE series Ethernet over SDH devices User Manual

Network Management. User s Manual. Version: 0.90

Using Cisco IOS Software

Industrial 24-Port 10/100/1000Mbps Managed Gigabit. Switch (-40~75 degrees C) with 4 Shared SFP Ports IGSW-24040T. Quick Installation Guide

RS-232/422/485 to Copper or Fiber. Ethernet Converter. User s Manual

Operation Manual System Management. Table of Contents

Configuration Guide. Upgrading AOS Firmware L1-29.1D July 2011

HOW TO INSTALL E-LD TO E-xD USING CONNECTION TO USB CONSOLE

ROM Monitor. Using ROM Monitor APPENDIX

Configurations for the Layer 3 Switch Router

Setting Up Your Cisco Unified Videoconferencing 3515 MCU

Management Security Switch SGSD-1022 / SGSD-1022P SGSW-2840 / SGSW-2840P. Quick Installation Guide

Assigning the Switch IP Address and Default Gateway

IFS NS P-4S-2X Quick Start Guide

Industrial L2/L4 Managed Gigabit Switch. With 4-Port 802.3at PoE+ IGS P4T/IGS P4T2S. Quick Installation Guide

SICOM3171 Series Managed Traffic Ethernet Serial Server. Software Operation Manual

Multi-port Coax + 2-port 10/100/1000T + 2-port. 100/1000X SFP Long Reach PoE over Coaxial. Managed Switch LRP-822CS / LRP-1622CS

SICOM3170 Series Managed. Traffic Ethernet Switch

NET101. RS232 / RS422 / RS485 to Ethernet Converter. User s Manual. Version 1.2

Industrial L2+ Multi-Port Full Gigabit. Managed Ethernet Switch IGS T2S/IGS UP1T2S IGS P2S/IGS P4S/IGS P2T2S

Cisco Branch Routers Series Network Analysis Module (NME-NAM-120S) Installation and Configuration Note, 4.2

HES-3106 SERIES 6 PORTS 10/100/1000BASE-T ETHERNET MANAGED SWITCH

CCNA 1 Chapter 2 v5.0 Exam Answers 2013

L2+ 24-Port Gigabit Managed Switch with. Hardware Layer3 IPv4/IPv6 Static Routing GS S8C GS S8CR. Quick Installation Guide

Installing the Cisco Unified Videoconferencing 3545 MCU

Chassis-based Media Converters

Advantech AE Technical Share Document

JNIOR Series 4 A Network I/O Resource Utilizing the JAVA Platform Getting Started Manual Release 2.0 NOTE: JANOS OS 1.1 or greater required

Lenovo Flex System SI Gb System Interconnect Module. Release Notes. for Networking OS 8.2

Initial Configuration for the Switch

Commissioning Avaya Secure Router 2330/4134

8-Port 10/100Mbps + 2G TP/SFP Combo. Managed Industrial Switch ISW-1022M / ISW-1022MT / ISW-1022MP / ISW-1022MPT / ISW-1033MT

Industrial L2+ Multi-Port Full Gigabit. Managed Ethernet Switch IGS-10020MT / IGS-10020PT/HPT / IGS-10080MFT IGS-12040MT / IGS-20040MT / IGS-20160HPT

STM-1 Mux SONET/SDH Multiplexer User Manual

DGS-1510 Series Gigabit Ethernet SmartPro Switch Web UI Reference Guide. Figure 3-1 Device Information window

Media Converters & Chassis

LevelOne. User Manual POH Port PoE Midspan Hub. Ver

L2+ Multi-Port Full Gigabit Managed Ethernet Switch IGS-10020MT / IGS-10020PT / IGS-10020HPT / IGS-10080MFT / IGS-20040MT. Quick Installation Guide

Transcription:

RC001-NMS1 (REV.C) User Manual Raisecom Technology Co., Ltd (08/2005)

CONTENTS Chapter 1. System Overview...2 1.1 RC002-16 Chassis...2 1.2 RC001-NMS1 Master Network Management Module...2 1.3 RC001-NMS2 Slave Network Management Module...3 1.4 AGENT Program...4 1.5 Network Management Platform and Network Element Manager...4 Chapter 2. Hardware Installation...5 2.1 RC001-NMS1 Installation...5 2.2 RC001-NMS2 Installation...5 Chapter 3. AGENT Setup...6 3.1 General Connection...6 3.1.1 Management through Console Port...6 3.1.2 Remote Management through TELNET...6 3.2 BOOTROM Guidelines...6 3.3 Guideline of Command Line Prompt...7 3.3.1 Command Line Prompt...7 3.3.2 Acquiring Help Information...8 3.3.3 Using the Historical Commands...8 3.3.4 Editing properties...8 3.4 System Command...9 3.4.1 Basic System Command...9 3.4.2 User Management...9 3.5 Configuration of Network Management Functions...10 3.5.1 Configure the IP address...10 3.5.2 Configure the Clock, Time Zone and Summer Time... 11 3.5.3 Configure SNMP...13 3.5.4 Configure SNTP...16 Chapter 4. System Maintenance...18 4.1 Maintenance Tasks...18 4.2 Configuration Files Management...18 4.2.1 View the Information of Configuration Files...18 4.2.2 Save the Current Configuration...19 4.2.3 Delete the Configuration...19 4.2.4 Export the Current Configuration...19 4.2.5 Import System Configuration...20 4.3 Start File Management (AGENT Program)...20 4.3.1 View the AGENT Program Information...20 4.3.2 Export the AGENT Program...20 4.3.3 Import the AGENT Program (AGENT Upgrade)...21 1

Chapter 1. System Overview 1.1 RC002-16 Chassis RC002-16 is 3U-high 16-slot chassis that can accommodate all kinds of 3U-high service modules, including copper to fiber media converters, fiber-optic modems, and interface converters. Models Description Model Description Dimension (mm) Power Supply RC002-16AC 16-slot, AC, network managed 440x131x410 220V AC,50Hz,80W RC002-16DC 16-slot, DC, network managed 440x131x410-48V DC,80W Sketch of the RC002-16 front panel condition condition Indicator Explanation PWR indicator: steady ON, the power supply is working in good condition PS1-5V indicator: steady OFF, the PS1 power supply to modules is in good condition PS1-12V indicator: steady OFF, the PS1 power supply to electric fans is in good PS2-5V indicator: steady OFF, the PS2 power supply to modules is in good condition PS2-12V indicator: steady OFF, the PS2 power supply to electric fans is in good 1.2 RC001-NMS1 Master Network Management Module RC002-16 supports SNMP. The SNMP can be implemented through deploying RC001-NMS1 Master Network Management module in the No.0 slot of the chassis. Model Specification RC001-NMS1 (REV.C) rack-mountable chassis master control module Sketch of the front panel of RC001-NMS1 2

1. LED Indicators on the Front Panel SYS: Network management system in operation. Flashing indicates working in good condition; otherwise, system is abnormal. PWR: Network management module power indicator. Steady on when supplying power. LNK/ACT: 10/100M Ethernet signal indicator. Steady on when the cable is properly connected; flashing when transmitting/receiving data. 100M: 10/100M Ethernet signal indicator. Steady on when the Ethernet is at 100M; steady off when at 10M. 2. RJ45 Interface on the Front Panel UPLNK: The port for connection between RC002-16-NMS1 module and RC001-NMS2. It complies with the RS-232 protocol. CONSL: The port for console. It can be connected to the serial port of console computer through RS-232 cable. ETHER: 10/100M Ethernet port. It can be connected to the Switch through straight-through cable, or to the host through crossover cable. The ETHER Ethernet port of each master control module has an IP address of which the address is 192.168.1.254 by default. Since there can not be two same address in one Ethernet section, please configure the master control module and its IP address through the CONSL port before connecting the network cable. Main functions of the master control module: 10/100M Ethernet port is used to connect with network management computer Communicate with slave control modules to implement cascade connection Configure and collect information about the working status and alarms of other service modules inserted in No.1 No.15 slots of both its own chassis and cascaded chassis Collect information about the temperature, fan speed, and power supply status of both its own chassis and cascaded chassis 1.3 RC001-NMS2 Slave Network Management Module A rack-mountable 16-slot chassis with RC001-NMS1 master control module can cascade 3 same chassis with RC001-NMS2 slave control module at the most. That is to say, a master network management module can manage 60 service modules at the most. There can be as many as master control module in one Ethernet. 3

1.4 AGENT Program AGENT program resides in RC001-NMS1 and be operated to implement the network management functions. It can be upgraded as per the enrichment of network managed product series. The version of AGENT program in RC001-NMS1 (Rev. C) is 5.x.x or above. Different versions of AGENT program require different versions of BOOTRM program correspondingly. 1.5 Network Management Platform and Network Element Manager The network management platform and network element manager are the software that are supposed to be installed on the network management server. Please refer to NVIEWNNM_3.1.2 (SP2) Installation Manual and NVIEWNNM_3.1.2 (SP2) Operation Manual for details. 4

Chapter 2. Hardware Installation 2.1 RC001-NMS1 Installation There are 3 ports on the front panel of RC001-NMS1. CONSL port (RJ-45). This port is used to connect the emulation terminal and perform the initial configuration installation. The connection parameters are default ones of hyper terminal (Baud rate: 9600; data bit: 8; parity bit: none; stop bit: 1; data flow control: none.) ETHER Ethernet port (RJ45). This 10/100Mps auto-sensing port is used to access the TCP/IP management network and communicate with network management platform. The straight-through cable shall be used to connect with Switch, and crossover cable to connect the host. UPLNK cascade connection port (RJ45). This RS-232 serial port is used to connect with other 3 chassis with RC001-NMS2 modules through serial lines. Only the straight-through cable can be used. RC001-NMS1 can only be installed into the No. 0 slot of RC002-16 chassis. 2.2 RC001-NMS2 Installation There are 3 ports that are all cascade connection ports. They can be used to connect with RC001-NMS1 master network management module through straight-through line, in order to increase the number of managed service modules. A master network management module supports 3 slave network management modules (60 service modules) at the most. The connection topology is as follows. 5

Chapter 3. AGENT Setup 3.1 General Connection 3.1.1 Management through Console Port First connect the PC COM port and CONSL port of RC001-NMS1 master network management module by using serial line. On the Windows platform, run the hyper terminal program or third party s serial port connection software, and configure parameters as follows. Baud rate: 9600 Data bit: 8 Parity bit: none Stop bit: 1 Flow control: none Press Enter for several times and the system CLI interface will be ready for management work. 3.1.2 Remote Management through TELNET After the initial of IP address through the console port, users are able to remotely manage the RC001-NMS1 through Telnet. 3.2 BOOTROM Guidelines Under the BOOTROM mode, users are able to perform management and maintenance to the flash memory and the files stored in it. During applying the power supply to RC001-NMS1, the system interface will prompt whether to enter BOOTROM mode or not for 3 seconds. Press the space bar to enter BOOTROM mode. System Prompt raisecom Commands under BOOTROM mode? - list all the commands c - Change parameters when upgrading the firmware through FTP download e - Format the flash sector where the firmware (AGENT program) resides h - List all the commands r - Reboot the system u - Upgrade the firmware through FTP download The following text will introduce the usage of c command. The comments are in the /* */. The comments are the information that shall be input by the users. 6

raisecom: c '.' = clear field; '-' = go to previous field; ^D = quit boot device : sng0 processor number : 0 host name : host file name : RC999 /*the file name that need to be downloaded*/ inet on ethernet (e) : 192.168.223.64 /*the IP address of this equipment*/ inet on backplane (b) : host inet (h) : 192.168.223.98 /*the IP address of FTP server*/ gateway inet (g) : user (u) : raisecom /*FTP user name*/ ftp password (pw) (blank = use rsh): 123 /*FTP password*/ flags (f) : 0x0 target name (tn) : agent startup script (s) : other (o) : 3.3 Guideline of Command Line Prompt 3.3.1 Command Line Prompt EXEC Description How to Access (By default) Prompt Common Exec User Users can display the basic information of the terminal, and display parameters User name: raisecom Password: :raisecom raisecom> Privileged Exec User Users can configure the basic information of the equipment, but not the operation parameters. From common exec Command: enable Password: raisecom raisecom# CONFIG Configuration Exec Users can configure the interface parameters of RC001-NMS1 From privileged exec Command: config raisecom(config)# SNMP Configuration Exec Users can configure the SNMP parameters of RC001-NMS1 From CONFIG exec Command: SNMP raisecom (config-snmp)# 7

3.3.2 Acquiring Help Information Command help Specific String? Specific String <Tab>? command? Function Description Get a brief description of the system in Chinese or English Get a list of commands that begin with certain (abbreviated-command-entry) For example: raisecom>en? enable Get the whole command For example: raisecom #show ver<tab> raisecom#show version List all the available commands in the current exec. For example: raisecom#? List all the keywords and options of a certain command, and also brief help information. raisecom#show? 3.3.3 Using the Historical Commands The system will keep 20 entries of historical command by default. Users can set up the number of kept entries by the following command. raisecom#terminal history <0-20> The history command can used to display the historical command entry. 3.3.4 Editing properties up arrow: last command entry down arrow: next command entry left arrow: left move the cursor by one character right arrow: right move the cursor by one character backspace: delete the left character of cursor Ctrl+d: delete the right character of cursor Ctrl+a: move the cursor to the beginning of the line Ctrl+e: move the cursor to the end of the line Ctrl+k: delete all the characters on the right of the cursor Ctrl+z: exit to Privileged Exec for different non-privileged execs 8

3.4 System Command 3.4.1 Basic System Command clear Clear the screen enable Enter Privileged User Exec exit Back to last command exec or logout help Display the help information of the system history Display the historical commands list List all the available commands under current exec quit Back to last command exec or logout terminal history <1-20> Change the number of entries memorized by console terminal time-out <0-65535> Change the time of logout disable Back to initial exec from privileged user exec logout Logout reboot Reboot the RC001-NMS1 Master module show version Display the system version information show terminal Display the operation information of system write Save the current configuration information 3.4.2 User Management The system default user name raisecom and password raisecom can be used to enter the common exec. Add a new user Step Command Description 1 user USERNAME password USERNAME The user name PASSWORD password The keyword PASSWORD The password 2 user USERNAME privilege USERNAME The user name <1-15> privilege The keyword <1-15> The user privilege 3 write Save the configuration information 4 show user Display the user information 3.4.2.1 delete a user no user USERNAME You have no enough right to change user information! This echo shows when privileged user whose priority is not 15 tries to create a new user. Only 15-priority users can perform this command. 9

3.5 Configuration of Network Management Functions 3.5.1 Configure the IP address The configuration of IP address shall be performed under CONFIG exec. 3.5.1.1 Enter CONFIG exec From Privileged User Exec config raisecom(config)# 3.5.1.2 Configure the IP address ipaddr A.B.C.D mask A.B.C.D gateway A.B.C.D set command success please execute "write" to save! Set the IP of RC001-NMS1 to 192.168.223.89, subnet mask to 255.225.255.0, and gateway to 192.168.223.1 raisecom#ipaddr 192.168.223.89 mask 255.225.255.0 gateway 192.168.223.1 3.5.1.3 Configure the auto negotiation of Ethernet port autonego (enable disable) set command success if you want to save it, please execute "write" to save! raisecom(config)#auto enable 3.5.1.4 Configure the speed and duplex mode of Ethernet port speed (10 100) duplex (full half) set command success if you want to save it, please execute "write" to save! raisecom(config)#speed 100 duplex full 3.5.1.5 Show Ethernet port information show ether 10

STAUS: link up AUTO: enable Speed: 100M Duplex: FULL raisecom(config)#show eth 3.5.2 Configure the Clock, Time Zone and Summer Time This should be done under CONFIG exec. 3.5.2.1 Enter CONFIG exec From Privileged User Exec config raisecom(config)# 3.5.2.2 Configure the clock clock set Use clock set to change the date and time of system clock set <0-23> <0-59> <0-59> <2000-2099> <1-12> <1-31> [Parameter] <0-23> hour; <0-59> minute; <0-59> second; <2000-2099> year; <1-12> month; <1-31> day; System time changed successfully Current system time: 06/06/2006 13:34:00 +08:00(DST) The command is executed successfully Current system time: 06/06/2006 13:34:00 +08:00(DST) Indicate the configured time and day does not exist and display the current system time No 30th or 31th in Feb. in leap year No 29th, 30th or 31th in Feb. No 31th in the month 11

Change the system date to September 30 th, 2003 and time to 8:30 0 second raisecom # clock set 8 30 0 2003 9 30 3.5.2.3 Enable the summer time clock summer-time Set successfully raisecom #clock summer-time enable 3.5.2.4 Start summer time clock summer-time recurring [Command format] clock summer-time recurring <1-5> ( sun mon tue wed thu fri sat ) <1-12> <0-23> <0-59> <1-5> ( sun mon tue wed thu fri sat ) <1-12> <0-23> <0-59> <1-1440> [Parameter] <1-5> summer time starting from which week, 5 indicates the last week week day summer time starting from what date of the week <1-12> summer time starting from which month <0-23> summer time starting hour <0-59> summer time starting minute <1-5> summer time ending at which week of the month, 5 indicates the last week week day summer time ending at which day of the week <1-12> summer time ending month <0-23> summer time ending hour <0-59> summer time ending minute <1-1440> summer time offset minute Set successfully Set unsuccessfully [Usage Guide] This command is used to set the starting time, the ending time and recurring of summer time. The format for starting time and the ending time is: xx month, xx week (or the last week), xx hour and xx minute. Raisecom# clock summer-time recurring 2 sun 4 2 0 2 sun 9 2 0 60 3.5.2.5 Configure the time zone [Introduction] Configure time zone [Command format] clock timezone {+ -} <0-11> <0-59> [Parameter] + East Earth time zone - West Earth time zone 12

<0-11> time zone recurring hour <0-59> time zone offset minute [Default] The default time is Beijing local time, which is eastern offset 8 hours [Command format] Privilege exec; privileged user. [Usage Guide] [Explanation of command execution echo] Set successfully [Example] Set the time-offset direction to West Earth, offset time is 5 hours and 40 minutes. Raisecom#clock timezone 5 40 3.5.2.6 Show system time show clock raisecom(config)#show clock Current system time: 05/23/2006 17:01:22 +08:00(DST) 3.5.2.7 Show summer time show clock summer-time-recurring raisecom#show clock summer-time-recurring Current system time: 06/06/2006 13:31:44-08:00 Summer time recurring: Disable raisecom#show clock summer-time-recurring Current system time: 06/06/2006 14:01:04-08:00(DST) Summer time recurring: Enable Summer time start: week 1 Tuesday June 12 00 Summer time end: week 1 Tuesday June 15 00 Summer time Offset: 30 min 3.5.3 Configure SNMP The configuration of SNMP shall be performed under SNMP configuration exec. 3.5.3.1 Enter SNMP exec From CONFIG configuration exec snmp raisecom(config-snmp)# 13

3.5.3.2 Configure the community name snmp-server community COMMUNITY (ro rw) Set the community read-only or read-write raisecom(config-snmp)# snmp-server community public ro 3.5.3.3 Enable/disable TRAP snmp-server trap (enable disable) Enable/disable TRAP raisecom(config-snmp)# snmp-server trap enable 3.5.3.4 Configure the MANAGER and port number of TRAP snmp-server trap <1-8> target A.B.C.D port <1-65536> trap: the number of Manager (8 at the most) target: the IP address of Manager port: the port number Set the first TRAP address, IP 192.168.1.1; Port 162 raisecom(config-snmp)# snmp-server trap 1 target 192.168.1.1 port 162 3.5.3.5 Delete the Trap Manager no snmp-server trap <1-8> Delete a Trap Manager raisecom(config-snmp)# no snmp-server trap 1 3.5.3.6 Remove all the Trap Manager configuration snmp-server trap clear Remove all the Trap configurations 3.5.3.7 Set the Contact information 14

snmp-server contact STRING Set the Contact information Set the contact information to admin raisecom(config-snmp)# snmp-server contact admin 3.5.3.8 Set ID information snmp-server id <0-65536> Set ID information Set the ID to 5 raisecom(config- SNMP)# snmp-server id 5 3.5.3.9 Set the Location information snmp-server location LOCATION Set the location information of the equipment Set the location of the equipment to haidian raisecom(config- SNMP)# snmp-server location haidian 3.5.3.10 Set the Name information snmp-server name NAME Set the name of the equipment Set the name of the equipment to RC002 raisecom(config-snmp)# snmp-server name RC002 3.5.3.11 Set the threshold of system temperature snmp-server temperature <0-100> Set the threshold of the chassis temperature. When the temperature gets too high, the system will send Trap information to the console. Set the temperature of the chassis to 20 raisecom(config-snmp)# snmp-server temperature 20 15

3.5.3.12 Load the default SNMP community load default community Use this command to load the default SNMP community raisecom(config-snmp)#load default community 3.5.3.13 Enquire SNMP information show snmp Display the SNMP information raisecom(config- SNMP)# show snmp System name: unknown System contact: unknown System location: unknown System ID: 1 System level: 1 System Temperature Alarm Threshold: 50 Read Community: public Write Community: private Send trap status: Enable Trap sink Target Address Target Port 1 0.0.0.0 162 2 0.0.0.0 162 3 0.0.0.0 162 4 0.0.0.0 162 5 0.0.0.0 162 6 0.0.0.0 162 7 0.0.0.0 162 8 0.0.0.0 162 3.5.4 Configure SNTP The system supports SNTP (system net time protocol) CLIENT to acquire the real time. The relevant configuration shall be performed under CONFIG exec. 3.5.4.1 Enter CONFIG exec From the privileged user exec config 16

raisecom(config)# 3.5.4.4 Acquire time from SNTP server sntp server A.B.C.D Acquire time from the designated SNTP server Acquire time from the host of 192.168.1.10 raisecom(config)# sntp server 192.168.1.10 3.5.4.5 Cancel acquiring time from SNTP server no sntp server Cancel acquiring time from designated SNTP server Cancel acquiring time from the host of 192.168.1.10 raisecom(config)# no sntp server 17

Chapter 4. System Maintenance 4.1 Maintenance Tasks Managing configuration files: view and store configuration files in the system, export to external storage, and import form external storage. Managing AGENT program: view the information of the program, export to external storage, and upgrade the AGENT program. When performing interactions between configuration files/agent program and external storages, RC001-NMS1 will act as the FTP client and the external storage or host shall be configured as the FTP server. After appointed user account, it is required to make corresponding configuration at the RC001-NMS1 console. 4.2 Configuration Files Management The current configuration of the system is stored in the following files. system.txt hostconf.txt slotconf.txt; Users can use write command to save the configuration files to flash memory. The system will load the configuration information during the next boot automatically. Users shall use download/upload command to exchange configuration files with external storage, through FTP or TFTP 4.2.1 View the Information of Configuration Files dir (c: d:) Function: view the files in flash memory Parameters: c: files in system partition d: files in configuration partition Read the configuration file sector raisecom#dir d: size date time name -------------------------------------------- 269 Jan-01-1980 00:00:00 hostconf.txt 1340 Jan-01-1980 00:00:00 system.txt 81 Jan-01-1980 00:00:00 usercfg.txt 7680 Jan-01-1980 00:00:00 slotconf.txt 18

4.2.2 Save the Current Configuration write Mode: privileged exec Function: save the current system configuration raisecom#write Writing running-config to flash, please wait... Successfully write to flash 4.2.3 Delete the Configuration del FILENAME Mode: privileged exec Function: delete the current system configuration raisecom#del slotconf.txt delete file slotconf.txt successfully. 4.2.4 Export the Current Configuration Upload startup-config (tftp ftp) Mode: privileged exec Function: export the current configuration files to export storage, through FTP or TFTP [Other Parameter] File name (system.txt; hostconf.txt; slotconf.txt) system.txt: SNMP-relevant information in AGENT, including IP address of Trap, port number, system contact information, system name, location, community string, temperature threshold, and alarm function status. hostconf.txt: information about the AGENT, including IP address, subnet mask, bit rate at Ethernet port, duplex mode, auto-negotiation status, and SNTP configuration information slotconf.txt: the configuration information of all the service modules in chassis. raisecom#upload startup-conf ftp Please input server IP Address:192.168.1.251 Please input FTP User name:target Please input FTP Password:target 19

Please input FTP Server File Name:slotconf.txt 4.2.5 Import System Configuration Download startup-config (tftp ftp) Mode: privileged exec Function: import the configuration files from external storage to RC001-NMS1, through TFTP or FTP. [Other Parameters] File name (system.txt; hostconf.txt; slotconf.txt) raisecom#download startup-config ftp Please input server IP Address:192.168.1.251 Please input FTP User name:target Please input FTP Password:target Please input FTP Server File Name:hostconf.txt Loading, please wait... Loading: 268... done Writing to flash, please wait....finished You've successfully download new config file new config works after the device reboots... 4.3 Start File Management (AGENT Program) AGENT program file is based on embedded operation system. The SNMP will be loaded when applied the power supply. Use dir command to view the files in flash memory. Use show version to view the version information. 4.3.1 View the AGENT Program Information dir (c: d:) Function: view the files in flash memory. Parameters: c: files in system partition d: files in configuration partition 4.3.2 Export the AGENT Program 20

upload system-boot (tftp ftp) Mode: privileged exec Function: export the current Agent program to external storage, through TFTP or FTP. [Other Parameters] File name The text in /* */ is the comment. Users shall input as per the comment. raisecom#upload system-boot ftp Please input server IP Address:1.0.0.1 Please input FTP User name:test Please input FTP Password:test Please input FTP Server File Name: /* Any file name*/ 4.3.3 Import the AGENT Program (AGENT Upgrade) download system-boot (tftp ftp) Mode: privileged exec Function: upgrade the Agent program, through FTP or TFTP [Other Parameters] The text in /* */ is the comment (Users shall input as per the comment) raisecom# download system-boot ftp Please input server IP Address:1.0.0.1 Please input FTP User name:test Please input FTP Password:test Please input FTP Server File Name: /* the Agent program name on external storage*/ 21

@2005 Raisecom Technology Co., Ltd. All trademarks are the property of their respective owners. Technical information may be subject to change without prior notification. 22