Installation manual plugs and connectors with screw connection (16/32 A)

Similar documents
Technical Manual Room temperature controller

Operating and Installation Manual. EASYLAB Expansion modules Type EM-TRF for 230 V AC mains voltage

Operating Instructions (Translation) 3. Safety Information. 1. Description. 2. Explosion Protection. Supply module Type 17-21BB-170x

Technical Manual Sensor / Switch actuator 1/1gang; 2/1gang; 2/2gang

/ 2CKA001473B Technical Reference Manual Compact combination 1/1gang with T13 SSA-F-1.1.

B63/ NS MS. EtherNet/IP LINK

Operating Manual / IEC. Explosion-Proofed Junction Boxes, Polyester. Wallücker Bahndamm 7 DE Kirchlengern

PTB 01 ATEX 2064 U, IECEx PTB U. Example / Beispiel / Exemple: Type Operating Instructions

Operating manual. Diagnostic adapter VAS Operating manual Diagnostic adapter VAS Client documentation Revision: 00 Version: 05/2018

SolConeX extra-low voltage flange socket

Technical Manual Movement detector/switch actuator, 1-gang

Flexoled FTP3HP RGB LED DMX Driver

INSPECTION CAMERA MODEL NO: CIC2410 OPERATION & SAFETY INSTRUCTIONS PART NO: GC0116

Technical Manual Sensor / Blind actuator, 1/1gang; 2/1gang

SIWAREX JB Aluminum Housing. Instruction Manual Edition 03/2006

Technical Manual Movement detector/switch actuator, 1-gang

Type Quickstart

PHOENIX CONTACT Pin. SUBCON-PLUS M ARCNET, MULTI/MININET (B&R), SYSTEM 2003 (B&R), P-NET SUCONET K1, K2 (EATON/Moeller),

SolConeX Wall-Mounted Socket, 16 A

650/1000 Fresnel 650/1000 PC 300/500 Antihalo 300/500 Fresnel theatre spotlight. user manual

Lucid arena pro LED luminaire

D-Pack 6 Classic ORDERCODE 50315

HX1 Bluetooth Stereo Headset

VR 71. Installation instructions. Installation instructions. For the competent person GB, IE. Publisher/manufacturer Vaillant GmbH

Expansion module EM-BAC-MOD-01. Installation manual

1 Channel Strobe Controller ORDERCODE 40226

38 MHz Passive Voltage Probe R&S RT-ZP1X

SUBCON-PLUS-PROFIB...

CPCI-PS24 24V-Power Supply

Operating Manual -ENGLISH- Page 1 KWG-ISO

UV Power Flood. User Manual. Order code: EQLED029

Operating instructions for AX5801. TwinSAFE drive option card for the AX5000 servo drive. Version: Date:

TEMPERIX S Clamp. FAFNIR GmbH Schnackenburgallee 149 c Hamburg Germany

Model P4017 Single Channel USB Oscilloscope. Quick Start Guide

POCKET MULTIMETER Model No: MM18

IPCB42501 / IPCB42551

Demonstration Case BENNING DB 1

PNOZ m ES RS232. Configurable Control System PNOZmulti. Operating Manual EN-01

CS2 DMX Distribution Splitter

Polymer Electric. Operating Instructions. Control Unit SG-EFS 1X4 ZK2/1 8k2. Version 3

Operation Manual. Capacitor Boxes adjustable 80 A / 125 A Track, 2,04 μf to 8 μf. Order Number

PTB 01 ATEX Example / Beispiel / Exemple. Type Operating Instructions

DMX LED Starcloth Systems

The following symbols are used to show dangerous operation or handling. Make sure you understand them before reading the guide.

UP-1-1 Channel Dimmer. User manual. dimmer pack

DPX-620III 6-Ch. dimmer pack. user manual

LED Colour Flood 10W / 30W RGB LED floodlight. user manual

UP-1-1 Channel Dimmer dimmer pack. user manual

Control Unit KEH-P / Force-1.DIN

Flow Sensor SONOFLOW CO.55

FTP1 Single Channel LED DMX Driver

Sliding shutter control Aluminium shutters

Explosion-Protected Arc-Fault Protection ExAFCI Arc-Fault Circuit Interrupter

Installation manual for for Schleifenbauer DPM3

Controller Smart Box Translation of operating and installation instructions

SKIVING MACHINE MAINTENANCE & INSTRUCTIONS MANUAL ASSK2. Allswage UK. Roebuck Street, West Bromwich, B70 6RB

Operating Instructions

Blitzer Strobe. User Manual. Order code: EQLED366

Crossfire. User Manual. Order code: EQLED061

BVS 17 ATEX E 117 X / IECEx BVS X Types 3320, 3321, 3323, 3360, 3361, 3363 AE3320, AE3321, AE3323, AE3360, AE3361, AE3363

LED Pixel Rail 40 RGB LED strip. user manual

PF LED Profile. User Manual

Explosion proof UL certified VoIP telephone. FernTel IP Z2 UL. Tabletop unit. Manual FHF BA /12

SINAMICS G130. Terminal Module 150 (TM150) Operating Instructions 03/2013 SINAMICS

REDUNDANCY MODULE TSP-REM360 AND TSP-REM600

Installation Guide. QBox-V6. Standalone/Spare V6 SDI QBox. Standalone/Spare V6 SDI QBox. Part No. A

Model 2460-KIT. Screw Terminal Connector Kit. Description / September 2014 *P * 1

Control unit SG-EFS 104/4L. EN Operating instructions. Innovative by tradition. Version SG-EFS 104/4L AC/DC 24 V

MDM 011-Z1 Regen Resistor

ZF LED Zoom Fresnel. User Manual

English. Operating Manual. Conductive point level switch MLR120. Retain for later reference. Companies / brands of GHM

TETRIS 2500 High Impedance Active Probe. Instruction Manual

BVS 17 ATEX E 117 X / IECEx BVS X Types 3320, 3321, 3323, 3360, 3361, 3363 AE3320, AE3321, AE3323, AE3360, AE3361, AE3363

SAFETY ADVICE (English)

MX3 BT LED Party Tube

Imprint. Preface. Issued by: supra Foto-Elektronik-Vertriebs-GmbH Denisstr. 28A Kaiserslautern Germany.

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

STR-3 STANDARD 3-PHASE 230 VAC TRANSFORMER CONTROLLER. Mounting and operating instructions

Large Police Light 100W ORDERCODE 80361

Product and Applications Description. Application Programs. Note. instabus EIB Technical Product Information. June 2005

D610H, D610H MKII, D610S, D610T dimmer pack. user manual

LED Pixel Rail Drive 640 controller. user manual

The following symbols are used to show dangerous operation or handling. Make sure you understand them before reading the guide.

TA18 active subwoofer. user manual

MANUAL. ENGLISH Showtec PSA-161 Ordercode: Highlite International B.V. Vestastraat EX Kerkrade the Netherlands

PHOENIX CONTACT - 01/2008

PV Module Installation Instructions

Manual. Polaron SMPS Watt power supply for chargers. No. S2024. Copyright Graupner/SJ GmbH

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

Technical Reference Manual

Promopar ORDERCODE 30120

HITACHI. EH-150 series PLC EH-RTD8 Resistance Temperature Detective input module Instruction manual. Safety precautions

RevueLED 150 Profile 3200K 26 LED spotlight. user manual

LIGHT BRICK - 12 X 3W TRI-COLOUR

Product and Applications Description. Example of Operation. Installation Instructions WARNING. Note. Application Programs

Network Camera. Quick Guide DC-B1203X. Powered by

Control unit SG-EFS 104/2W. EN Operating instructions. Innovative by tradition. Version SG-EFS 104/2W 24 V=/~

TPC25 active crossover. user manual

Polymer Electric. Operating Instructions. Control Unit SG-TRS 3X8. Version 1

Electromotoric actuators Torques up to 60 Nm Running times ¹) s. ¹) Predefined by the basic unit (LMV5...)

Transcription:

EN Installation manual plugs and connectors with screw connection (16/32 60003213 Issue 04.2016 2016-04-01

Table of contents 1 About this manual 3 1.1 Structure of the warnings 3 1.2 Symbols used 4 1.3 Signal words used 4 2 Intended use 5 3 General safety instructions 6 4 Packaging, transport and storage 7 4.1 Packaging 7 4.2 Transport 7 4.3 Storage 7 5 Design 8 6 Assembly and disassembly 9 6.1 Connecting a cable to a 16-A / 32-A plug or socket 9 6.2 Disconnecting a cable from a 16-A / 32-A plug or socket 11 7 Cleaning and care 14 8 Decommissioning and disposal 15 2 / 16

1 About this manual This manual describes the assembly and disassembly of plugs and sockets with screw connections of Bals Elektrotechnik GmbH & Co. KG is an integral part of the product and must be kept in safe custody during the product service life must be read carefully and understood before use and any work. 1.1 Structure of the warnings The following picture illustrates the structure of a sample warning. 1 Hazard-specific symbol 2 Signal word 3 Type and source of the hazard 4 Possi ble consequences of failing to comply 5 Procedure for avoiding hazards 3 / 16

1.2 Symbols used General warning of a hazardous area Warning dangerously high voltage Notice 1.3 Signal words used All warnings in this manual are clearly highlighted. The following signal words are used for warnings: DANGER WARNING CAUTION NOTICE Warns of dangers which will lead to serious injuries or to death if the instructions are not followed. Warns of dangers that may lead to serious injuries or to death and/or cause considerable damage to property if the instructions are not followed. Warns of dangers that may lead to reversible injuries and/or considerable damage to property if the instructions are not followed. Warns of dangers that may lead to operational disruptions and/or considerable damage to property. Damage to the environment, too, may occur if the instructions are not followed. 4 / 16

2 Intended use Plugs and sockets with screw connections are built for professional use. The installation and the fixed connection to the mains supply should be carried out only by trained and qualified experts. Any use going beyond the intended use is considered to be improper. The manufacturer is not liable for damages resulting from improper use. Any such risk shall be borne solely by the user. In case of unauthorised modifications or conversions, the CE conformity becomes null and void, and thus, also all claims for warranty. Modifications may lead to risks for life and limb as well as damage to the plugs and sockets or loads connected. Factory-fitted labels and markings on the plugs and sockets should not be removed, modified or blurred. Protect against foreign bodies and impact of weather The plugs and sockets meet either the protection degree IP44, IP54 or IP67 in accordance with DIN EN 60529 (VDE 0470-1), depending on the respective design. Each of these mean: Protection degree IP44: Protected against solid bodies with a diameter beyond 1.0 mm, e.g. a wire Protection against water sprayed from all sides Protection degree IP54: Protected against dust in damaging quantity Complete protection against contact Protection against water sprayed from all sides Protection degree IP67: Dust-proof Complete protection against contact Protection against temporary immersion Environment The following operating temperatures apply for the safe operation of the product: 5 / 16

Standard version Military version -25 C... +40 C -33 C... +49 C 3 General safety instructions Safe use is ensured only if this manual is followed completely. Before installation, commissioning or operation, read this manual thoroughly. The plugs and sockets must be installed, maintained and put into operation properly by qualified experts in accordance with the laws, ordinances and standards. Keep easily combustible and explosive materials away from the plugs and sockets. Handle the cables with care by always pulling at the plug and not the cable when unplugging, by preventing the cable from getting damaged mechanically, by keeping intense heat away. Never use faulty products or products with dirty, scratched or damage contacts. Keep the contacts on the product clean. Avoid tripping hazards. 6 / 16

4 4.1 4.2 4.3 Packaging, transport and storage Packaging Packaging materials are valuable raw materials and can be reused. The packaging materials should therefore be brought to an appropriate recycling facility. If this is not possible, dispose of the packaging materials according to the locally applicable regulations. Transport Check the delivery for completeness and integrity. If you identify transit damage or if the delivery is incomplete, notify your dealer or supplier immediately. Storage The product must be stored in clean condition and protected from dust and humidity. The original packaging is best suited for this purpose. 7 / 16

5 Design Based on an example, the following figure illustrates the main components of the plugs and sockets with screw connections. 1 Use with screw terminals for all types of copper conductors 2 Housing 3 Cable gland with multi-grip as integrated strain relief Conductor cross-sections The following table displays the possible conductor cross-sections that can be connected to the plugs and sockets: Design Possible conductor cross-section 16 A 1 mm 2... 2.5 mm 2 32 A 2.5 mm 2... 6 mm 2 Cable diameter The following table displays the cable diameters that can be used for plugs and sockets with multi-grip: Design Possible cable diameter 16 A, 3-pin to 5-pin 8 mm... 18 mm 32 A, 3-pin to 5-pin 11 mm... 23 mm Technical specifications The technical specifications of the plugs and sockets depend on the design. You will find them in our catalogue or on our website http://www.bals.com. 8 / 16

6 Assembly and disassembly DANGER Danger to life by electrical voltage The supply cable may carry high electrical voltage that is fatal. Pay attention to the five safety rules of electricity: 1. De-energise 2. Secure the supply from being switched on again 3. Ensure the de-energised condition 4. Connect to earth and short circuit 5. Cover or cordon off adjacent live parts 6.1 Connecting a cable to a 16-A / 32-A plug or socket Proceed as follows: 1. Make sure that the cable is de-energised. 2. Loosen the screws in order to disconnect the inserts with the screw terminals (1) from the housing (2). 3. Remove the insert with the screw terminal in front out of the housing. 9 / 16

4. Push the cable about 50 cm wide through the cable gland and housing. 5. Strip the cable to the required length (16-A designs: 60 mm; 32-A designs: 70 mm). 6. Remove the insulation from the individual conductors (16-A designs: 7 mm; 32-A designs: 12 mm). 7. For better, permanent contact, provide the individual conductors with suitable conductor end sleeves. 8. The terminals are open at the time of delivery. Guide the individual conductors into the opening (5) and tighten the screws (4) with a torque of at least 0.8 Nm. Take care to see that only the individual conductor (without insulation) is clamped. Pay attention to the marking of the terminals and ensure that the assignment of the individual conductors to the terminals is correct. 10 / 16

9. Connect the housing and the insert with the screws foreseen for this purpose. 10. Next, tighten the cable gland (3). The tightening torque must be between 4 Nm and 7 Nm for the 16-A designs and between 5 Nm and 9 Nm for the 32-A designs. Please refer to the embossing on the cable gland for the exact value of the respective design. Secure the cable gland using the screw placed on the side for this purpose (6, depending on the design). 11. Check that the cable is seated tightly in the plug or socket. 6.2 Disconnecting a cable from a 16-A / 32-A plug or socket 1. Make sure that the cable is de-energised. 2. If the cable gland (3) is secured with the help of a screw (6), loosen this screw. 3. Loosen the cable gland. 4. Disconnect the joint between the housing (2) and the insert (1). To do this, loosen the connecting screws. 11 / 16

5. Push the housing and the cable gland back on the cable until the connections in the front part are easily accessible. 6. Loosen the screws (4) of the terminals and pull out the individual conductor. 12 / 16

7. Pull the cable out of the housing and out of the cable gland. 13 / 16

7 Cleaning and care It is recommended to clean the device as required. Use a dry cloth to clean the device. Use a wet cloth if the device is very dirty. DANGER Electrical voltage The device contains parts that carry hazardous voltage that may be fatal. 1. Pull out the plugs to the loads before cleaning them. 2. Make sure that the plug covers are closed. 3. Never use steam or water jet cleaners. NOTICE Damage to the plastic parts. Corrosive cleaning agents may attack or destroy the plastic parts. Use only a cloth moistened with water for cleaning. 14 / 16

Notes 8 Decommissioning and disposal Send the worn-out product for recycling or for proper disposal. Always make sure to observe and follow the local regulations. The product should not be disposed of in household waste. Environmental damage and risk to personal health are avoided with proper disposal. 15 / 16

Bals Elektrotechnik GmbH & Co. KG Burgweg 22 57399 Kirchhundem GERMANY Tel.: +49 27 23 / 7 71-0 Fax: +49 27 23 / 7 71-1 77 E-mail: info@bals.com Disclosure to third parties only with the consent of Bals Elektrotechnik GmbH & Co. KG. All rights reserved. Only valid at the time of printing. Update when reused.