Installing And Programming The Off-Premise Extension Interface On The Digital Communications System

Similar documents
Installing And Programming The Analog Terminal Interface On The DXP, DXP Plus, and FX Series Digital Communications Systems

Installing The Loop Start Line Board In The FX Series Digital Communications System

Installing And Programming The Digital Voice Announce Equipment On The DXP, DXP Plus, And FX Series Systems

Installing The DSU II Digital Telephone System

Junos WebApp Secure 5.0 Hardware Guide

SERVICE MANUAL MODEL SSP-363-E (FORMERLY SSP-365-E)

Industry Standard Telephone (IST) Station User s Guide. DXP, DXP Plus, and FX Digital Telephone Systems

SERVICE MANUAL MODEL SSW-321-X

OPERATOR S MANUAL MODEL LS110 MINI-PBX SIMULATOR

SERVICE MANUAL MODEL SSW-321-F MODEL BLW-321-F

SERVICE MANUAL MODEL SSW-321-D

SERVICE MANUAL. MODEL SSW-321-Fr1

Digital Telephone System. Speakerphone and Monitor Telephone Station User s Guide

Installing and Programming the Caller ID Feature

Installing The Personal Computer Interface Unit

Installation Notes TII Model 341 Protector

SERVICE MANUAL FOR. MODEL MHW-341-Fr1 MAGNETIC HOOKSWITCH WALL TELEPHONE

SERVICE MANUAL FOR MODEL WPP-531-X-ADA-STROBE WEATHERPROOF TELEPHONE WITH OPTIONAL STROBE FEATURE. EQUIPPED WITH SPK1.

COMDIAL. ExecuTech User s Guide. Made &&t in the USA 1 / Multiline Key Telephone

EntraGuard Bronze. Quick Start Guide. Telephone Entry. 1.0 Specifications. 2.0 Unit Installation

1. Carefully unpack the um260 s shipping carton and check the contents for damage.

SuperBus 2000 Phone Interface/Voice Module Installation Instructions

Intelligent Channel Bank Shelf

Service Manual For. -IP Voice over Internet Protocol -ACH** Handset cord length Inches

SERVICE MANUAL MODEL WPP-531-X-ADA MODEL SSP-511- X-ADA

SERVICE MANUAL FOR MODEL WPP-531-D WEATHERPROOF TELEPHONE WITH OPTIONAL ADA FEATURE

Omnitron Systems Technology, Inc. 1. iconverter. 19-Module Managed Power Chassis User s Manual

TOA INTERCOM SYSTEM TELEPHONE LINE INTERFACE

Power Supply (48Vdc, 2.5A)

SERVICE MANUAL MODEL SSC-303-F (FORMERLY 303-FS)

EP/2 Installation Instructions

Site Preparation CHAPTER

Data Isolation Cards. ADSL High Voltage Isolation Card. Single Line Voice Isolation Card With CID, CW & MWI. Floated 130VDC or 120VAC Input P30121

HOUSING DEVICES, INC. HDI ADA - ARCU. Installation & Operations Manual. Made in the USA

Installation of the POTS splitter card requires the following steps: Determining the cables you need. Installing the POTS splitter chassis

SERVICE MANUAL FOR MODEL WPP-531-D WEATHERPROOF TELPHONE OR MODEL HOB-531-D WEATHER RESISTANT TELPHONE

SERVICE MANUAL FOR MODEL WPP-531-D2 WEATHERPROOF TELEPHONE OR MODEL HOB-531-D2 WEATHER RESISTANT TELEPHONE

SERVICE MANUAL FOR MODEL SSC-500-F (FORMERLY 501-FSZ) STAINLESS STEEL HANDS FREE CHARGE-A-CALL TELEPHONE EQUIPPED WITH LOW-POWER SPEAKER BOARD

SERVICE MANUAL MODEL SSC-301-F (FORMERLY 301-FS) MODEL BLC-301-F (FORMERLY 301-F)

SERVICE MANUAL MODEL SSC-303-D (FORMERLY 303-DS)

NT1B-300 Rack Installation Instructions

SERVICE MANUAL MODEL SSP-550-X (FORMERLY SSP-510-X)

Installing the Cisco VG224 Voice Gateway

DXP, DXP Plus, Impact FX Digital Communication System

Installing the Fiber Optics Card

DSU II. System Manual. Digital Telephone System. Supports Impact, Impression, DigiTech, and Scout Telephones

Digital Telephone System System Manual

Radio Shack Telephone Tester ( )

Multi Cell Wireless Telephone User s Guide. For Comdial Systems

SERVICE MANUAL MODEL SSW-520-F

Power Supply. Users Guide PRODUCT MANUAL. WESTELL.COM Westell Technologies MNL rd

DXP, DXP Plus, and FX Series Digital Communications System

Model HU-224/225. Technical Information TI.224/ Humidity Transduce r FOR ADDITIONAL INFORMATION SEE HU-224/225 DATA SHEET

SERVICE MANUAL MODEL WPP-331-D WEATHERPROOF TELEPHONE MODEL HOB-331-D WEATHER RESISTANT TELEPHONE. and MODEL SSP-311-D STAINLESS STEEL PANEL TELEPHONE

PRODUCT DESCRIPTION SPECIFICATIONS INSTALLATION. Dialer codes PRODUCT DIAGRAM. DL2 Dialer Module Digital Alarm Communicator Transmitter. Warning!

EAR K. Installation and Programming. Manual

V-9941A ONE ZONE HANDSFREE TALKBACK CONTROL UNIT

SERVICE MANUAL MODEL SSW-521-F (FORMERLY SSW-521-FS)

Chapter 2. Installing the Chapter 2. Contents

Basketball Shot Clock Set LX2180 Manual

RMB Peripheral Units Installation Guide

Installing and Setting Up the Components

CIB 3125 (122A) Off-Premises Range Extender. Installation Instructions. Installed By Qualified Technician Only CIB

SERVICE MANUAL MODEL SSW-521-D2-ADA

This Datasheet for the IC660BBA026. Block 24/48Vdc Analog Current Source 6 Inputs.

C5C Cross-Connect System

MODEL SST3-MV INSTALLATION INSTRUCTIONS FOR FEDERAL MODEL SST3-MV SELECTABLE SIRENTONE-MULTI VOLT

MA-4006, MD-4006 and MU-4006 Mounting Assemblies

Total Reach ISDN/DDS Isolation Card P P30059 Isolation Card

Replacing the Power Supply

This Datasheet for the IC660BBA104. Block 115Vac/125Vdc Analog Current Source 4 Inputs / 2 Outputs

IMI /02 printed in U.S.A. FX II Digital Communications System Cabinet Installation Instructions

Installation Job Aid for Ethernet Routing Switch 3600 Series

Trademark Generation II Series Intercom System Installation and Operation Reference Guide

TRC-190 User s Manual

Impact Attendant for Windows PC Attendant Console User s Guide For The DXP, DXP Plus and FX Series Digital Communications Systems

Installing the Tracer MP503 Input/Output Module Ordering number: ,

Hardware Manual INS05 June Installing the Cabinet. 2. PCB Installation 3. Installing Extensions and Trunks. 4. Optional Equipment

TrueCom. Building Communications Systems 5110-Series Controllers. UL Listed. Features. Operation. Description

AT&T. ZoneMate 3 Service Manual. PagePac 20 Voice Paging System. MERLIN CS Connection And Operation

Service Manual For. -IP Voice over Internet Protocol -ACH** Handset cord length Inches

SERVICE MANUAL MODEL SSP-561-X-ADA

Technical Practice GS-1 LOOP START TO GROUND START CONVERTER. Issue 7, December, Contents. Testing and Operation. Repair and Replacement

Specifications, Installation, and Operating Instructions

Analog Monitor Installation Manual

Six-Slot T1 Mini-Repeater Apparatus Case

Quick Start Installation Guide

Multiple Digital Messaging Unit

Model 7416LED

VIP-812A DUAL NETWORKED STATION PORT

Installing Sentor. Hardware Installation

USER MANUAL. MODEL 552 Series. High Speed Telco Surge Protectors. SALES OFFICE (301) TECHNICAL SUPPORT (301)

Installing the Cisco MDS 9020 Fabric Switch

RMB-3 Peripheral Unit. Installation Guide INSTALLATION GUIDE WESTELL.COM. Westell Technologies Part # Rev. A

SERVICE MANUAL MODEL SSP-350-X

InnoMedia Business VoIP ATA Models

Visit us at

THROWMASTER 409 T-1 System Transfer Set

Level-Lance Model 5400A

Acoustic Design Series

Transcription:

R Installing And Programming The Off-Premise Extension Interface On The Digital Communications System 1.0 Introducing The Off-Premise Extension Interface This publication describes the features, applications, installation, specifications, and operation of the off-premise extension interface (OPX-X). The OPX-X is a multipurpose accessory with dual circuits that provide the following features: OFF-PREMISE EXTENSION This feature adapts most industry-standard telephone devices to the digital communications system and allows them to be remotely located. The OPX-X will accept both tone (DTMF) and pulse (rotary) dialing from these devices. TIE-LINE This feature allows you to connect two systems to each other using single-pair wiring of dedicated telephone lines. MODEM ADAPTER This feature allows the flow of switched data between a data source and a data receiver through the DXP Plus analog station ports. The OPX-X is a dual off-premise extension (OPX) unit. It is housed in a self-contained metal enclosure that you can either wall or rack mount. The OPX-X has an internal power supply and ringing generator. Dual, high quality, low-loss, balanced, telephone transmission circuitry supports two off-premise extensions. Each off-premise circuit can drive a load with a maximum ringer equivalence number (REN) of two (2) thus allowing more than one industry-standard telephone connection at each off-premise location if desired. The OPX-X will support virtually any industry-standard telephone device such as 500 and 2500-type telephones, cordless telephones, answering machines, and data modems. The OPX-X provides the interfacing capability required to connect these devices to analog station ports in digital communications system. This manual has been developed by Comdial Corporation (the Company ) and is intended for the use of its customers and service personnel. The information in this manual is subject to change without notice. While every effort has been made to eliminate errors, the Company disclaims liability for any difficulties arising from the interpretation of the information contained herein. The information contained herein does not purport to cover all details or variations in equipment or to provide for every possible contingency to be met in connection with installation, operation, or maintenance. Should further information be desired, or should particular problems arise which are not covered sufficiently for the purchaser s purposes, contact Comdial, Inside Sales Department, Charlottesville, Virginia 22906. Printed in U.S.A. IMI89 209.02 9/95

IMI89 209 Installing And Programming The OPX-X 1.1 Detailing The Specifications Electrical Specifications Power requirements: 117VAC +/- 10% single-phase @.13A maximum Ringing voltage: 95 VAC Nominal @ 20 Hz Power rated to maximum REN = 2.0 Battery feed voltage: 50 VDC nominal Loop current limits: 20 ma min. at 1500 ohms 50 ma max. at 0 ohms DC loop limits: 1500 ohms maximum including telephony device (Approximately 20,000 feet with #24 AWG twisted-pair cable and 400 ohm device load) Cable insulation resistance: 30,000 ohms minimum Cable requirement OPX-X to digital communications system 2-pair, twisted Cable terminations: 623-type, 4-conductor minijacks Dialing: Ringing cadence: Industry-standard DTMF Dial pulse (rotary) with nominal make/break ratio of 40/60 @ 10 PPS 1 second on/4 seconds off (typical for intercom calls) 2 Installing The OPX-X

Installing And Programming The OPX-X IMI89 209 Environmental Specifications Operating temperature: 32-122 F (0-50 C) Humidity: 90 % relative, non-condensing Mechanical Specifications Height: Width: Length: Weight: 3.0 in. 10.25 in. 11.50 in. 8 lbs. (plus 2 lbs. for packing material) Industry/Regulatory Standards FCC registered FCC certified, Part 15 (class A) UL listed Key System: CVW7WC-12829-KF-E Hybrid/Key System: CVW7WC-16553-MF-E Leased Line Specifications Facility interface code: Line conditioning: 0L13C Dry metallic Installing The OPX-X 3

IMI89 209 Installing And Programming The OPX-X 2.0 Installing the Off-Premise Extension Interface 2.1 Detailing The Mounting Considerations You can attach the OPX-X to any sturdy, flat, surface. It may be vertically rack mounted if desired. you must locate the OPX-X within six (6) feet of the proper electrical outlet. It requires a 117VAC circuit, with a third-wire ground, supplied to a standard (NEMA 5-15R) electrical outlet. you must keep the distance between the OPX-X and the KSU to 25 feet or less. Be sure that the mounting location is secure and dry and have adequate ventilation. Be sure that the temperature range of the location is within 32-122 F (0-50 C). If the mounting surface is damp or if it is concrete or masonry material, you must attach a backboard to the mounting surface. Suitable mounting backboards are available commercially or can be constructed out of 1/2-inch plywood cut to size. Tools and hardware required for mounting the KSU cabinet include: Fasteners - wood screws (1/4 x 1-inch round head), toggle bolts, or wall anchors. Screwdriver - to match fasteners. Electric drill - if prepared holes are required. Connecting tool - for fastening wires to a type-66 connector block. Crimping tool - for 623-type modular plugs. 2.2 Mounting The Cabinet 1. Unpack, and carefully inspect the OPX-X for shipping damage. Notify the shipper immediately of any damages found. Verify that the packages contain all parts and accessories needed for proper installation and operation. 2. If a backboard is required at the mounting location, attach it securely to provide a stable KSU mounting surface. 3. Use the base of the OPX-X as a template or measure for mounting hole locations per the dimension details shown in Figure 1. 4. Drill holes in the mounting surface of a proper size to accommodate the hardware being used. If necessary, prepare these holes with inserts, anchors or other attachment devices as dictated by the type of mounting surface. 5. Attach the OPX-X to the mounting surface with four (4) screws installed through the mounting flange and into the mounting surface holes. Note that the flange holes are elongated with an enlargement at one end of the hole. This feature allows the mounting screws to be partially installed in the mounting surface before the KSU is hung on them. 4 Installing The OPX-X

Installing And Programming The OPX-X IMI89 209 AW1002A 11.50 3.0 10.25 7.0 8.75 Detailing The OPX-X Dimensions Installing The OPX-X 5

IMI89 209 Installing And Programming The OPX-X 2.3 Connecting The Equipment Route the necessary cabling, and connect the OPX-X to the digital communications system per the connections detailed on the next page. The installation requires a grounding wire separate from the third-wire AC line cord ground. The OPX-X cabinet provides a ground stud. Connect a #10 or #12, insulated, solid copper, wire between this ground stud and either the ground stud on the digital communications system cabinet or a reliable earth ground. Plug the AC line cord for the OPX-X into a 117 VAC outlet. Observe the status light on the unit, and insure that it turns on steady. CAUTION To help insure that foreign voltages, which could appear on the TELCO lines, do not damage the system, be sure gas discharge tubes or similar protection devices are installed, and properly grounded, in all connected TELCO lines. 2.4 Verifying Proper Installation Use a voltmeter to check for the presence of either AC or DC voltage on the OPX1 and OPX 2 ports. Make these voltage measurements with all system wiring installed and the AC power turned off. 1. Measure for both AC and DC voltage between the TIP lead of the OPX 1 port and the KSU grounding stud. The measured voltage must be 0 volts. 2. Measure for both AC and DC voltage between the RING lead of the OPX 1 port and the KSU grounding stud. The measured voltage must be 0 volts. 3. Repeat steps 1 and 2 for the OPX 2 port. 4. Apply AC power to the OPX-X. 5. Repeat steps 1 3. The measured voltage must now be approximately -50VDC. 6 Installing The OPX-X

Installing And Programming The OPX-X IMI89 209 Connecting The Equipment Installing The OPX-X 7

IMI89 209 Installing And Programming The OPX-X 2.5 Setting The Configuration Switches You must set the OPX-X s configuration switches to match the digital communications system. The switches are located in an opening on the left side of the cabinet. Setting The Configuration Switches Switch System Condition Setting A System programmed to assign analog station port to OPX-X for circuit 1 Yes Closed No Open* B System programmed to assign analog station port to OPX-X for circuit 2 Yes Closed C D (note 2) Key- System Voice first intercom signalling enabled (note 1) Configured Tone first intercom signalling enabled with.. Prime line automatic enabled Hybrid system configured Off-premise device is intercom only Off-premise device has access to outside line through the digital communications system NOTE 1: This switch setting matches the system requirements. It is not possible to perform voice signalling from a device connected through an OPX-X to the common equipment. No Open* Closed* Open Open Open Closed* Open NOTE 2: When you have programmed the system to allow the off-premise device to have access to outside line, you must also enable a signal delay to prevent transmission of extraneous DTMF tones from the device over the outside line. When you enable this delay, the user must wait approximately 2 seconds before speaking when performing call announce and paging over intercom line. When the off-premise device is an intercom only device with no access to an outside line, you can disable the delay to facilitate faster cut-through to call announce and paging. *Factory settings LEFT OF SIDE HOUSING CLOSED OPEN A BOTTOM OF HOUSING B D AW1001 Locating The Switches 8 Installing The OPX-X

Installing And Programming The OPX-X IMI89 209 3.0 Programming For Off Premise Extension Interface Operation When operated through the OPX-X, the IST provides basic intercom service coupled with the ability to access outside lines. You can program the analog station port (through which the IST is being interfaced via the OPX-X) for either prime intercom operation or prime line automatic and idle line preference operation. Default is for prime intercom. Under either operating condition, you can program the station port to receive outside line ringing and to match either the rotary or DTMF dialing employed by the IST. 3.1 Detailing The Prime Intercom Operating Condition With key-system configured digital communications systems, a system multiline telephone user can extend line access for call origination to an IST station by employing the call transfer feature. To provide outside line ringing to a prime intercom IST, program the OPX-X station port to have the ringing line preference feature and then enable ringing for all lines that you want to ring at the IST. With hybrid configured digital communications systems, you can make outside lines available to the IST for call origination by programming the IST for line group access. With line group access, the IST user can access an outside line by dialing the group access code over the intercom line. The digital communications system then selects one of the grouped lines for IST use. 3.2 Detailing The Prime Line Automatic Or Idle Line Preference Operating Condition You can program an outside line as a prime line at the station port through which the IST is being interfaced, or you can program that station port for idle line preference and then assign several lines to the station port. With either prime line automatic or idle line preference, the IST has outside line dial tone for call origination when its user lifts its handset. You can enable outside line ringing at the IST station port that you have programmed for either prime line automatic or idle line preference. Alternately, you can enable the ringing line preference feature for the IST station port. The intercom line is still available to an IST even though you have provided outside line access. After going off-hook, the IST user obtains intercom dial tone by performing a hookflash (press and release the hookswitch) or by pressing the TAP button if one is available. Hookflash either drops the outside line (if the used dialed no digits after lifting the handset) or (if the user dialed some digits) places the line on hold and provides intercom dial tone. 3.3 Detailing The Distinctive Ringing Condition Intercom calls that ring at equipment connected through an OPX-X have a different cadence than outside calls have. If desired, you can disable this distinctive ringing feature to make the intercom ring cadence the same as that for outside calls. 3.4 Detailing The Through Dialing Condition You can program the station port through which the IST is being interfaced for through-dialing or you can disable the feature. The system automatically enables the feature when you connect an OPX-X to the station port. Through dialing enabled is necessary if the connected IST is a dual-tone multifrequency (DTMF) tone dial device that requires that its generated dialing tones pass through the OPX-X, the common equipment, and onto a tone dial compatible telephone line. If the IST is a rotary telephone, you must disable the through dialing feature. Installing The OPX-X 9

IMI89 209 Installing And Programming The OPX-X 3.5 Programming Procedures The OPX-X automatically identifies itself as an analog terminal interface for the digital station board as soon as you connect it to the digital communications system. Prime Line Programming Prime Line Type When you enable this feature, the station automatically selects a line, line group, or intercom number for use when the station user takes the station off hook. Use the programming procedures shown below to select the line port, line group, or intercom number to serve as the prime station calling interface. 3. From stations menu, select station programming. 4. Type personal intercom number or previously assigned name and press ENTER. 6. Press SPACE BAR for desired value and press ENTER. 9. Repeat steps 4-8 for each station or press ESCAPE to end. Prime Line Use this procedure to choose the prime line. 4. Type personal intercom number or station name and press ENTER. 6. From prime line menu, type line port number (type as n,nn,nnn or n nnn) and press ENTER. 9. Repeat steps 4-8 for each station or press ESCAPE to end. Prime Intercom Number Use this procedure to choose the prime intercom number. 4. Type personal intercom number or station name and press ENTER. 5. From station programming menu type item number for feature and press ENTER. 6. From prime intercom menu, type personal intercom number and press ENTER. 9. Repeat steps 4-8 for each station or press ESCAPE to end. 10 Installing The OPX-X

Installing And Programming The OPX-X IMI89 209 Idle Line Programming Idle Line Preference With you enable this feature, a station automatically connects to an idle line when the user lifts the telephone s handset. 3. From stations menu, select COS programming and press ENTER. 4. Type class of service number (1-32) and press ENTER. 5. Fro COS programming menu, type item number for feature and press ENTER. 6. Press SPACE bar for feature setting. 9. Repeat steps 4-8 for each COS or press ESCAPE to end. Idle Line Priority If you give a station the ability to automatically connect to an idle assigned line when the user takes the handset off-hook, take this programming action to set the priority in which the system chooses the idle lines for use. You can place up to eight lines in this priority list. 4. Type personal intercom number or previously assigned name and press ENTER. 6. Type any eight line numbers (type as n,nn,nnn or n nnn) and press ENTER. 9. Repeat steps 4-8 for each station or press ESCAPE to end. Ringing Line Preference When you enable this feature, a station can automatically connect to a ringing line when a user takes his or her telephone off-hook. 2. From the main menu, select stations and press ENTER. 3. From the stations menu, select COS programming and press ENTER. 4. Type class of service number (1-32) and press ENTER. 5. From the COS programming menu, type item number for feature and press ENTER. 6. Press SPACE bar for feature setting. 9. Repeat steps 4-8 for each COS or press ESCAPE to end. Installing The OPX-X 11

IMI89 209 Installing And Programming The OPX-X Dialing Mode Program the line port to match either a DTMF tone or a rotary (pulse) dialing line as supplied by the central office (CO). 2. From main menu, select lines and press ENTER. 3. From lines menu, select line programming and press ENTER. 4. Type line port number or name and press ENTER. 5. From line programming menu, type item number for feature and press ENTER. 6. Press SPACE bar for feature setting and press ENTER to accept setting. 9. Repeat steps 4-8 for each line port or press ESCAPE to end. Pulse Dial Make/Pulse Dial Break (Pulse Dial Ratio) Use this procedure to set the make/break ratio for rotary dial signalling to match rotary dial line requirements. You can set the line make/break ratio for rotary dial (pulse dial) signalling in a more flexible manner to match many different rotary dial line requirements. You can set the make time and the break time independently in one msec. increments to any time from one to 99 msec. 1. Press CONTROL T for main menu, 2. From main menu, select system and press ENTER. 3. From system menu, select timing and press ENTER, 4. From timing menu, type item number for line pulse make and press ENTER. 5. Type desired time (1 99) and press ENTER, 6. From timing menu, type item number for line pulse break and press ENTER. 7. Type desired time (1 99) and press ENTER. 8. Press ESCAPE twice, 9. Type y to accept changes, n to reject them, or r to resume editing and press ENTER. Pulse Dial Interdigit Time You can set the interdigit time between dial pulses when the system pulse-dials a number over a line. The digital communications system defaults this time to 200 msec. and provides a range of timing values between 100 msec. and one sec. that you can set in 100 msec. increments. 1. Press CONTROL T for main menu, 2. From main menu, select system and press ENTER. 3. From the system menu, select timing and press ENTER. 4. From timing menu type item number for feature and press ENTER. 5. Press SPACE bar to select desired time and press ENTER to select setting. 6. Press ESCAPE twice, 7. Type y to accept changes, n to reject them, or r to resume editing and press ENTER. 12 Installing The OPX-X

Installing And Programming The OPX-X IMI89 209 Flexible Ringing Assignments Program ringing assignments on a per station/per line/per intercom number basis. Ringing can be immediate, delayed, or special purpose. Use the procedures in this section to customize the ringing features for the system. Direct Ringing Use this procedure to choose the line ports that you want to ring at a station as soon as a call appears. Direct ringing sounds during the day 1 and day 2 time periods but does not ring during the night ringing mode or during the manual night transfer (of ringing) operation. 4. Type personal intercom number or previously assigned name and press ENTER. 5. From station programming menu, type the item number for feature and press ENTER. 6. Press CONTROL E for edit. 7. Type a for add or r for remove and press ENTER. 8. Type line port number (type as n,nn,nnn or n nnn) and press ENTER. 9. When finished, press ESCAPE twice. 10. Type y to accept changes, n to reject them, or r to resume editing and press ENTER. 11 Repeat steps 4-10 for each station or press ESCAPE to end. Delayed Ringing Use this procedure to choose the line ports that you want to ring at a station after waiting a short time period from when a call appears. Delayed ringing sounds during day 1, day 2 time periods, during the night ringing mode, and during the manual night transfer (of ringing) operation. 4. Type personal intercom number or previously assigned name and press ENTER. 6. Press CONTROL E. 7. Type a for add or r for remove and press ENTER. 8. Type line port number (type as n,nn,nnn or n nnn) and press ENTER. 9. When finished, press ESCAPE twice. Installing The OPX-X 13

IMI89 209 Installing And Programming The OPX-X Day 1 Ring Use this procedure to choose the line ports that you want to ring at stations during the day 1 ringing mode time period. Refer to the paragraph below titled, Day 1, Day 2, and Night Ringing Begin and End Times, to set the beginning and ending times of this ringing. 4. Type personal intercom number or previously assigned name and press ENTER. 7. Type a for add or r for remove and press ENTER. 6. Press CONTROL E to edit. 8. Type line port number (type as n,nn,nnn or n nnn) and press ENTER. 9. When finished, press ESCAPE twice. 10. Type y to accept changes, n to reject them, or r to resume editing and press ENTER. 11. Repeat steps 4 10 for each station or press ESCAPE to end. Day 2 Ring Use this procedure to choose the line ports that you want to ring at stations during the day 2 ringing mode time period. Refer to the paragraph below titled, Day 1, Day 2, and Night Ringing Begin and End Times, to set the beginning and ending times of this ringing. 4. Type personal intercom number or previously assigned name and press ENTER. 6. Press CONTROL E to edit. 7. Type a for add or r for remove and press ENTER. 8. Type line port number (type as n,nn,nnn or n nnn) and press ENTER. 9. When finished, press ESCAPE twice. 10. Type y to accept changes, n to reject them, or r to resume editing and press ENTER. 11. Repeat steps 4-10 for each station or press ESCAPE to end. Day 1, Day 2, And Night Ringing Begin And End Times With this programming procedure, set the begin and end times of the day 1, day 2, and night ringing time periods. 2. From main menu, select system and press ENTER. 3. From system menu, select system parameters and press ENTER. 4. From the system parameters menu, select day 1, day 2 or night ringing begin times and press ENTER. 5. Type times in 24 hour format (hh:mm) and press ENTER. 6. Press ENTER (repeatedly if needed) to place cursor at next time desired setting. 7. Repeat step 5 and press ENTER. 8. Repeat steps 6 and 7 until all times are set and press ENTER. 9. When finished, press ESCAPE twice. 10. Type y to accept changes, n to reject them, or r to resume editing and press ENTER. 11. Repeat steps 4-10 for each station or press ESCAPE to end. 14 Installing The OPX-X

Installing And Programming The OPX-X IMI89 209 Night Ring (Night Transfer - Of Ringing) Choose the line ports that you want to ring, along with the delayed ringing line ports, at stations during the night ringing mode of operation. The ringing arrangement that you configure here is the arrangement that is active both during the automatic night ringing time period and whenever the attendant manually activates the night transfer (of ringing) operation. Do note that the attendant commanded night ringing period supersedes the automatic night ringing period. Refer to the above paragraph titled, Day 1, Day 2, and Night Ringing Begin and End Times, to set the time for the automatic night ringing period. 4. Type personal intercom number or previously assigned name and press ENTER. 6. Press CONTROL E. 7. Type a for add or r for remove and press ENTER. 8. Type line port number (type as n,nn,nnn or n nnn) and press ENTER. 9. When finished, press ESCAPE twice. 10. Type y to accept changes, n to reject them, or r to resume editing and press ENTER. Ring No-Answer Rings This procedure sets the amount of rings that sound at one station port before the call rolls over to ring at another station port. Any system feature that requires a ring no-answer value (for example, call forwarding) uses the setting that you program here. The system defaults the ring no-answer value at regular station ports to four rings, and it defaults ports programmed to function as voice mail ports to three rings. This insure that, at default, the voice mail equipment will have sufficient time to answer a call before it rolls over to the next port. 4. Type personal intercom number or previously assigned name and press ENTER. 6. Type number of rings 0 6 and press ENTER. 8. Type y to accept changes, n to reject them, or r to resume editing and press ENTER. 9. Repeat steps 4-8 for each station or press ESCAPE to end. Installing The OPX-X 15

IMI89 209 Installing And Programming The OPX-X Personalized Ringing Tone Program a station to ring in one of several distinctive tones for proprietary digital telephones and in one of four distinctive tones for analog telephones. 4. Type personal intercom number or previously assigned name and press ENTER. 5. From the station programming menu, type item number for feature and press ENTER. 6. Type ring tone choice and press ENTER. 9. Repeat steps 4-8 for each station or press ESCAPE to end. While industry-standard telephones do not provide personalized ringing, you can set distinctive ringing for them. An industry-standard telephone can sound one ring cadence for intercom calls and a different ring cadence for outside calls or it can sound the same ring cadence for both types of calls. You must select one of these ringing styles on a station class of service basis. All industry-standard telephones with the same class of service have the same ringing style. NOTE: Do not enable distinctive ringing for voice mail ports. 3. From stations menu, select COS programming and press ENTER. 4. Type class of service number (1 32) that corresponds with class of service assigned to the IST and press ENTER. 5. From COS programming menu, type row number for IST distinctive ringing and press ENTER. 6. Press SPACE bar for feature setting. 9. Press ESCAPE to end. Through Dialing (Thru-Dialing) This procedure allows DTMF tones that are generated by an external device connected to the system through necessary interface equipment to pass through the system and out to any line connection. 2. From main menu, select station and press ENTER. 3. From station menu, select station programming and press ENTER. 4. Type personal intercom number or previously assigned name of station being programmed and press ENTER. 6. Press SPACE bar for desired setting and press ENTER. 9. Repeat steps 4 8 level for each station or press ESCAPE to end. Accredited by the Dutch Council for Certification for certification and registration activities. Comdial s Quality Management System Is Certified To The ISO 9001 Standard. R Charlottesville, Virginia 22901-2829 World Wide Web: http://www.comdial.com/