Coordination of Surge protection devices

Similar documents
3 Design of the electrical installation protection system

2 Principle of lightning protection

BS th Edition wiring regulations Furse overview

Low voltage. Acti 9. the efficiency you deserve. Catalogue 03/2016

Overvoltage Protection

Lightning and Surge Protection of Photovoltaic Installations. Leutron GmbH 2013 Leinfelden-Echterdingen, Germany

PRF1 12.5r/PRF1 Master/ PRD1 25r/PRD1 Master Type 1 and 2 LV surge arresters

Surge Protection Devices and Surge Protection Kit

Reliability in Surge Protection. Photovoltaic Systems.

Overvoltage Protection Devices

Overvoltage Protection Devices

C C CIRCUIT-BREAKERS Moulded-case (MCCB), general. 1. Introduction. 2. General description

Overvoltage Protection Devices

Technical features OVR Surge Protective Devices Type 1 & Type 1+2

Surge Protection Devices Ex9UE2

Overvoltage Protection Devices

Modular surge protective devices (SPDs) Cat. Nos :

Modular surge protective devices

mcbs, EQUIPMENT NEW PRODUCTS 2014 Voltage surge protectors & other control and signalling devices Time & light sensitive switches

Modular surge protective devices (SPDs)

Modular surge protective devices (SPDs)

Surge Protection Devices Type 1+2

SPM Series Plug-in Surge Protection

Making the Right Choices In Lightning & Surge Arrestors Some Basics:

SPM Series Plug-in Surge Protector Type 2/3 (Test Class II/III) Single & Three Phase Surge Arresters

US Catalog March Surge protective devices (SPDs) UL range

SPM Series. Plug-in Surge Protection

DEHN tests and analyses DEHN Test Centre.

The Wave Breaking Factor and it s Vital Role in Surge Protection Device Coordination. Hans Slagter, DEHN + SOHNE

PROTEC Z LV the universal solution for transient switching protection for LV motors, generators, transformer LV secundaries, VSD and UPS equipment

Technical Requirements for High-voltage DC Power Feeding Interfaces of ICT equipment

ETITEC - Lightning and Surge Arresters

SURGE PROTECTIVE DEVICES

Manual for overvoltage protection for LED luminaires rev 1

Commercial and Industrial LV Power Protection

Lightning and Surge Arresters

Overvoltage Protection Devices

Increased Safety for Switchgear Cabinets CI Arresters with Integrated Backup Fuse

ENGR. MARITES R. PANGILINAN, P.E.E.

R3&A Limited, Cobourg, ON

Lightning & Surge Protection for Wind Turbine Systems

MULTI-POLE PHOTOVOLTAIC SYSTEMS. COMPACT and MODULAR Housing

Quality assurance Test Facilities for Gapless ZnO Surge Arresters in High Voltage Division of CPRI, Bengaluru

In the simplest terms, surge protective devices (SPDs) prevent damaging transient voltage surge levels from reaching the devices they protect.

Chapter J. Protection against voltage surges in LV. Contents. General. Overvoltage protection devices. Choosing a protection device

Page 14-4 Page Page 14-4 SURGE PROTECTION DEVICES TYPE 2 VERSIONS WITH PLUG-IN CARTRIDGE 1P, 1P+N, 2P, 3P, 3P+N, 4P

6/2 Product overview. 6/3 Lightning arresters, type 1. 6/5 Combination surge arresters, type 1 and type 2. 6/7 Surge arresters, type 2

Technical Data. Circuit Protection - Surge Protection Devices. Ver 1.0 CUSPD1110. Brief product description:

TRI-SERVICE ELECTRICAL WORKING GROUP (TSEWG) 07/16/08 TSEWG TP-3: SURGE PROTECTOR PERFORMANCE AND EVALUATION CRITERIA

Company Profile Surge Protective Devices

Minia. Application manual Overvoltage protections

The right solution for every home

B. System Design and Performance Requirements

NEW surge protective devices

Surge Protection. tra Combinations. Surge Protection

Equipment protection

Lightning and Surge Protection for PV Systems

The new Arc Fault Detection Device S-ARC1 Maximum safety easy installation

YOU NEED A WHOLE- HOUSE PROTECTION SYSTEM

RESIDUAL CURRENT CIRCUIT BREAKERS OFE (6 ka)

White Paper Surge Protective Devices in Automatic Transfer Switches

Type 1 Arresters. Use in installations with short-circuit currents up to 100 ka rms DEHN + SÖHNE / protected by ISO 16016

Varius SUMMARY OF MODELS OF HRC FUSE-LINKS

Application Note. Table 1. Test requirements by equipment type

Session Two: Effective Surge Protection Installation

Surge Protection for Surveillance Systems

Externally Gapped Line Arresters Smart Solution for Stable Power Supply

SURGE PROTECTION LIGHTNING & EARTHING EQUIPMENT

Lightning Current Equipotential Bonding SPDs

BETA Protecting Overvoltage Protection Devices

Externally Gapped Line Arresters Smart Solution for Stable Power Supply

Telcordia GR-1089-CORE Issue 4 Topics Primary Protection

wietap wietap Overvoltage Protection Tensions running high

SPD Catalogue. SPD Catalogue. for AC applications

C60PV-DC. IEC / EN e. Main characteristics Operating voltage (Ue) 800 V DC Rated insulation voltage (Ui) 1,000 V DC Breaking capacity (Icu)

CPS block & CPS nano UL rd Ed. Surge protective devices (SPD)

ASCO SERIES 230 Automatic Transfer Switch

Secondary Surge Arrester Instruction Manual Page 1 of 5

Building Surge Protection Information Pack

Surge Protective Device

voltage surge protectors low voltage type 1 (class I / B) voltage surge protectors low voltage type 2 (class II / C) Distribution board protection

GENERAL UL th EDITION BID SPEC: SURGE PROTECTIVE DEVICES Prepared by THOR SYSTEMS, INC.

TDS Transient Discriminating Surge Diverters

Common Departures Interconnecting Facilities Requirements

RB60 RANGE. Miniature circuit breakers

Type of surge arrester

Bulletin 290/291 ArmorStart LT Distributed Motor Controllers Specifications

M ISCELLANEOUS A CCESSORIES O BSTRUCTIONS LIGHTS MISCELLANEOUS ACCESSORIES OBSTRUCTION LIGHTS

Protection of PHOTOVOLTAIC SYSTEMS against LIGHTNING and OVERVOLTAGE. Surge Protection Device

This is a preview - click here to buy the full publication TECHNICAL REPORT

Cirprotec. Specialists in Lightning and Surge Protection for Photovoltaic Systems. Includes new plug-in SPD range and insulation monitoring device

OPTIMISED LUMINAIRE PROTECTION

PHOTOVOLTAIC PLANTS Comprehensive lightning protection

INTRODUCTION TO SPECIFYING SURGE PROTECTION SURGE PROTECTION NOTE 1 INTRODUCTION TERMS PROBABILITY OF SURGES APPEARING:

Arc protection relay. Features Three-phase overcurrent function. Application

Medium Voltage Metal-Enclosed Harmonic Filter Systems

Application-optimised DEHNshield Combined Arrester

Direct current distribution

Surge Protection Devices

MV Network Switchgear, Protection and Control

Transcription:

Coordination of Surge protection devices Design guide Surge arresters for commercial and industrial buildings Surge protection devices: how to choose them?

coordination How to choose surge protection devices? As everyone knows, surge protection devices or surge protective devices (SPD) protect electrical equipment against over-voltages caused by lightning. That said, it is not always easy to know which to choose. Choosing the right surge arrester and protective circuit breakers involves a considering a wide range of parameters related to types of surge protection devices, circuit breaker arrangements and risk assessment. Let s try to see things more clearly First of all, current standards define three categories of surge protective devices for low-voltage electrical installations: Type 1 Type 2 Type 3 Install in the main switchboard in buildings with lightning protection systems. Can discharge very powerful lightning currents. Install in the main power distribution switchboard. Discharge currents from indirect lightning strikes, inductive and conductive overvoltages, and switching transients. Dedicated to the protection of specific devices. Very low discharge capacity. Ishould be used as part of lightning protection systems i.e. when lightning rods or meshed cages are installed Should always be used. Supplementary surge protective devices: Used in Types 1+2+3 combinations in industrial facilities where a lightning protection systems is in place Used in Types 2+3 combinations when there is no lightning protection systems What surge protective devices should be chosen and where should they be installed? Lightning protection should be approached from an overall viewpoint. Depending on the application (large industrial plants, data c enters, hospitals, etc.), a risk assessment method must be used to guide in choosing optimal protection (lightning protection system, surge protective devices). National regulations, moreover, may make it compulsory to use the EN 62305-2 standard (Risk assessment). In other cases (housing, offices, buildings not sensitive to industrial risks), it is easier to adopt the following protection principle: In all cases a Type 2 surge protective device will be installed in the electrical installation s incoming-end switchboard. Then, the distance between that surge protective device and the equipment to be protected should be assessed. When this distance exceeds 30 meters, an additional surge protective device (Type 2 or Type 3) should be installed near the equipment. SPD location in the building without Lightning rod underground MV supply underground LV supply Type 2 Type 2/3 If L>30m 2 Catalogue valid as of January 1, 2017 www.lsp-international.com

coordination SPD location in the building with Lightning rod underground MV supply underground LV supply Type 1 Type 2/3 If L>30m And the sizing of surge protective devices? Then, the sizing of Type 2 surge protective devices depends mainly on the exposure zone (moderate, medium, high): there are different discharge capacities for each of these categories (I = 20, 40, 60 ka (8/20μs)). max For Type 1 surge protective devices, the minimum requirement is a discharge capacity of I = 12.5 ka (10/350μs). Higher values imp may be required by the risk assessment when the latter is requested. How to choose the protection devices associated with the surge protective devices? Finally, the protection device associated with the surge protective device (circuit breaker or fuse) will be chosen according to the short-circuit current at the place of installation. In other words, for a residential electrical switchboard, a protection device with an I < 6 ka will be chosen. SC For office applications, the I is generally < 20 ka. SC Manufacturers must provide the table for coordination between the surge protective device and the associated protection device. More and more surge protective devices already incorporate this protection device in the same enclosure. Simplified selection principle (excluding full risk assessment) Surge protective device No Type 2 surge protective device Is there a lightning protection system on the building or within a radius of 50 m around the building? Yes Type 1 + type 2 or type 1+2 Surge protective device Risk level Risk level.. Low... 20 ka 40 ka High... Imax 60 ka... 12.5 ka Min. limp 25 ka... Disconnection device short-circuit current at place of installation of Surge protective device 3 Catalogue valid as of January 1, 2017 www.lsp-international.com

coordination Coordination between the surge protective device and its disconnect circuit breaker I Disconnector coordinated with surge protective device MCCB / MCB MCB An external disconnecting device must be coordinated with a surge protective device in order to achieve: continuity of service: do not trip due to surge current, do not increase (U P) voltage protection level. effective protection against all types of overcurrents: overload due to SPD aging, short circuit of low intensity (impedant) due to temporary overvoltages, short circuit of high intensity due to SPD degradation. L L L SPD Circuit breaker closed Circuit breaker closed Circuit breaker open Nonconducting SPD Loads Conducting SPD Loads Conducting SPD Loads MCCB: MCB: SPD: Molded-case circuit breaker. Modular circuit breaker.. in normal operation in operation during the lightning stroke Surge protective device at end of life on short circuit The disconnecting device must be coordinated with the surge protective device. It is designed to meet the following two constraints: Resistance to lightning current The resistance to lightning current is an essential characteristic of the surge protective device's external disconnecting device. The device must be capable of passing the following standardized tests: not trip upon 15 successive impulse currents at In. Resistance to short-circuit current The breaking capacity is determined by the installation rules (IEC 60364 standard): the external disconnecting device must have a breaking capacity equal to or greater than the presumed short-circuit current Isc at the point of installation. when this device is integrated into the surge protective device, conformity with product standard IEC 61643-11 naturally ensures protection. 4 Catalogue valid as of January 1, 2017 www.lsp-international.com

coordination (cont.) External disconnecting device Fuse protection combined with the SPD Circuit breaker protection combined with the SPD Lightning protection of equipment Protection of installation (at end of the surge protective device's life) Continuity of service(at end of the surge protective device's life) Maintenance (at end of the surge protective device's life) = = All types of disconnecting devices protect the equipment satisfactorily = + Achieved if compliance with the MCB/SPD coordination table Protection from (impedant) short circuits of low intensity Protection against (impedant) short circuits of low intensity not well ensured + Only the surge protective device circuit is shut down = Change of fuses + + Immediate resetting Main reasons why the disconnecting device recommended by the manufacturer should be used: if the disconnecting device's rating is lower than the recommended rating: risk of the disconnecting device opening in normal operation. if the disconnecting device's rating is higher than the recommended rating: risk of non-disconnection during a temporary voltage surge. 5 Catalogue valid as of January 1, 2017 www.lsp-international.com

coordination (cont.) Coordination between the surge protective device and its disconnect circuit breaker in the event of a short circuit This table shows: the rating, curve and short circuit current level of the disconnector coordinated with the surge protective device. I SC (ka) 50 63 A 63 A 63 A 80 A 100 A 160 A 36 63 A 63 A 63 A 80 A 100 A 160 A 25 Disconnector 15 10 10 A 10 A 20 A 40 A 50 A 20 A 50 A 50 A 80 A 80 A 100 A 100 A 160 A TLP10 SLP20 SLP40 6 10 A 20 A 40 A 50 A 80 A 20 A 40 A 50 A TLP10 TLP10 SLP20 SLP20 SLP40 SLP40 FLP7 FLP7 FLP12,5 FLP12,5 FLP25 FLP50 10 ka 10 ka 20 ka 40 ka 60 ka 12.5 ka 25 ka 50 ka I max / I imp 5 ka 5 ka 10 ka 20 ka 30 ka 30 ka 60 ka 60 ka I n Type 3 (1) (1) U OC: 10 kv. Type 2 Type 1 Low risk Medium risk High risk Maximum risk ( ) * For lightning impulse current withstand 6 Catalogue valid as of January 1, 2017 www.lsp-international.com

coordination (cont.) Coordination between the surge protective device and its disconnect fuse in the event of a short circuit I SC (ka) 50 36 125 A gg max. 125 A gg max. 125 A gg max. 25 Disconnector 15 10 25 A gg (14x51 mm) 63 A gg (22x58 mm) 63 A gg 80 A gg (22x58 mm) 80 A gg 160 A gg 315 A gg 315 A gg 250 A gg 25 A gg (10x38 mm) 32 A gg (14x51 mm) 50 A gg (14x51 mm) 6 TLP10 SLP20 SLP20 SLP40 SLP40 FLP7 FLP7 FLP12,5 FLP25 FLP25 FLP50 10 ka 20 ka 40 ka 60 ka 12.5 ka 25 ka 50 ka I max / I imp 5 ka 10 ka 20 ka 30 ka 30 ka 60 ka 60 ka I n Type 3 (1) (1) U OC: 10 kv. Type 2 Type 1 Low risk Medium risk High risk Maximum risk 7 Catalogue valid as of January 1, 2017 www.lsp-international.com

coordination (cont.) Coordination between two surge protective devices, upstream/downstream When two surge protective devices are installed in an electrical installation, coordination is needed according to IEC 61643-12 to obtain an acceptable stress distribution between the two surge protective devices according to their permissible energy "E". L I F I1 MCB Zd I2 MCB Up1 Up2 SPD 1 SPD 2 L and Zd represent the cable length and impedance respectively between the 2 surge protective devices. U p2: level of protection of surge protective device SPD2. U w: impulse withstand voltage of the equipment to be protected. I max: maximum discharge current. I F: lightning current: I max of SPD1 = I1 + I2 E: permissible energy. MCB: modular circuit breaker. SPD: surge protective device. For coordination between two surge protective devices, a minimum cable length between these 2 surge protective devices is needed to ensure that: @I2 < I max SPD2. @U p2 < U w. @E2 < E max SPD2. 8 Catalogue valid as of January 1, 2017 www.lsp-international.com

coordination (cont.) Minimum distance between two surge protective devices, upstream/downstream 2 For a cable section of 16 mm and an impulse current equal to the maximum discharge current (I max surge protective device. ) of the upstream Example If FLP7 is installed in the incoming panelboard, the second SPD TLP10 must be installed at a cable length of 8 meters from the first one. Type 2 Type 1 Upstream surge protective device SLP20 SLP40 SLP20 SLP40 FLP7 FLP12,5 FLP25 FLP25 FLP7 0 m 10 m 10 m 10 m SLP40 0 m 0 m 2 m 10 m 10 m 10 m Type 2 Downstream surge protective device SLP20 SLP40 SLP20 0 m 0 m 2 m 0 m 3 m 2 m 10 m 10 m 0 m 0 m 2 m 10 m 10 m 10 m 1 m 0 m 2 m 2 m 10 m 10 m TLP10 3 m 7 m 4 m 9 m Type 3 8 m 10 m 10 m TLP10 2 m 6 m 4 m 7 m 7 m 10 m 10 m 9 Catalogue valid as of January 1, 2017 www.lsp-international.com

Wenzhou Arrester Electric Co., Ltd. Add: No. 140 East Xinghua Road, Huanghua, Yueqing 325605 Zhejiang, China Tel: +86-577-62652173 Fax: +86-577-27899688 http://www.lsp-international.com Email: sales@lsp-international.com 2017 - Arrester Electric - All rights reserved.