Operating Instructions

Similar documents
Zener Barriers Bulletin 937Z

MANUAL Surge Protectors

Operating Instructions. Intrinsically Safe Isolation Relay for Switches Model: REL manual_rel-6_0505

PROCESS AUTOMATION INSTRUCTION MANUAL FIELDBUS SURGE PROTECTOR F*-LBF-I1.32 F*-LBF-D1.32

Assembly MAU. MUX 4 Channels 8 Channels Zone 1

PROCESS AUTOMATION. MANUAL Z-System. Zener Barriers ISO9001

Assembly MAU. MUX 4 Channels 8 Channels Zone 1

INSTRUCTION MANUAL. SIL 3 Relay Output Module DIN-Rail Models D1092S-069, D1092D-069 D1092S D1092D-069

INSTRUCTION MANUAL. Universal AC Input Switching Power Supply 24 Vdc Output DIN-Rail Models PSD1000, PSD1000F PSD PSD1000F

Hazardous Area Protection

Operating Manual / IEC. Explosion-Proofed Junction Boxes, Polyester. Wallücker Bahndamm 7 DE Kirchlengern

Operating Instructions (Translation) 3. Safety Information. 1. Description. 2. Explosion Protection. Supply module Type 17-21BB-170x

PHOENIX CONTACT - 12/2007

Termination Board FC-GPCS-SAI16-PF. Features. Assembly. Function. Connection. SAI-1620m HART 24 V DC (I), 24 V DC (II) Fault. Zone 0, 1, 2 Div.

M E M O R A N D U M I.S.

FLEX Ex Spring Clamp Terminal Base

ADAMCZEWSKI. Ordering data AD-STVEX 710 GVD Option: Factory-software configuration as per customer specifications.

Termination Board FC-GPCS-RIO16-PF. Features. Assembly. Function. Connection USIO/UPIO 24 V DC (I), 24 V DC (II) Fault. Zone 0, 1, 2 Div.

MACX MCR-EX-SD LP(-SP)

PI-EX-ME-2NAM/COC-120VAC

Termination Board. HiCTB08-SCT-44C-SC-RA. Features. Assembly. Function. Connection. 24 V DC (I), 24 V DC (II), Fault. Zone 0, 1, 2 Div.

PI-EX-ME-2NAM/COC-24VDC

Signal processor MS96 for flow sensors MS96-11EX0-R/230VAC

Technical Data. General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm. Short-circuit protection

Safety Barriers. CEAG safety barriers can be used for all kinds of instrumentation applications.

Intrinsically Safe Barriers

D1093S INSTRUCTION MANUAL. D SIL 3 Relay Output Module with Line and Load diagnostics. DIN-Rail Model D1093S

Loop-powered Transmitter for Thermocouple Type K (NiCr-Ni)

4 Remote I/O. Digital Output Module 8-Channel Version Type 9475/ from Rev. F

Digital Output Module 8-Channel Version for Zone 1 Series 9475/

PHOENIX CONTACT - 05/2007

Operating instructions (Safety-related part ATEX and IECEx) Inductive NAMUR sensors NN504A NN505A NN506A NN507A /00 08/2015

Distributed Intrinsically Safe Fieldbus Applications

Digital Output Module 8-Channel Version for Zone 2 Series 9475/

PTB 01 ATEX Example / Beispiel / Exemple. Type Operating Instructions

Interface and Supply module. IPC 3x0i / PSC 3x0i

Digital Output Module 4-Channel Version for Zone 1 Series 9475/

Safety instructions. IECEx TUN Ex ia IIC T6 Gb

4 Remote I/O. Analog Output Module HART Ex i / I.S. Outputs, 8 Channels Series 9466/12

Installation & Operation Manual

MINI MCR-SL-UI-2I. Configurable signal duplicator. Data sheet. 1 Description

QUINT-BUFFER/24DC/24DC/40

Inductive dual sensor For rotary actuators NI4-DSU35TC-2Y1X2/S933

Technical Data. General specifications. Output type Rated operating distance s n 8 mm

Safety instructions Overvoltage protection B81-35

D5090S INSTRUCTION MANUAL. D A SIL 3 Relay Output Module for NE Load. DIN-Rail and Termination Board, Model D5090S

MINI MCR-SL-RPS-I-I. Repeater power supply, active. Data sheet. 1 Description

MINI MCR-SL-PT100-UI(-SP)(-NC)

TFR5. Room or outdoor temperature sensor. Operating instructions for temperature sensor. English page 1...5

Installation & Operation Manual

Assembly. Front view. LED yellow: Relay output. LED red: LB/SC Power Rail

Operating instructions Evaluation system for flow sensors VS / / 2013

RAD-DO8-IFS. I/O extension module, eight digital transistor outputs. Data sheet. 1 Description

Technical Data. General specifications Switching element function PNP NO/NC Rated operating distance s n 5 mm

How to calculate an Intrinsically Safe loop approval.

SMARTLINE RM76 Supplementary instructions

5 Fieldbus Technology

16-Channel Digital Input Termination Card 24Vdc

MINI MCR-SL-CVS NC

Refer to attachment for more details. Andreas Meyer

SYSTEM DESCRIPTION H-System

Digital Output Module 8-Channel Version for Zone 2 Series 9475/

Operating instructions. Speed monitor D / / 2014

Inductive sensor Dual sensors with extended temperature range NI4-DSU35TC-2Y1X2/S97

INTRINSICALLY SAFE ACOUSTIC EMISSION TRANSDUCERS

Magnetic field sensor Magnetic-inductive Proximity Sensor BIM-M12E-Y1X

PHOENIX CONTACT - 02/2008

MACX MCR-EX-SL-NAM-R(-SP)

Inductive sensor For rotary actuators NI4-DSU35TC-2Y1X2/S933

MACX MCR-EX-SL-NAM-2RO(-SP)

PanelView Plus/VersaView CE Terminals and Display Modules

16-Channel Digital Input Termination Card 24Vdc

PHOENIX CONTACT - 01/2008

Temperature Converters

MINI MCR-SL-PT100-UI. Active resistance thermometer measuring transducer. Data sheet. 1 Description

Redundancy Module QUINT-DIODE/40

Digital Output Module 4-Channel Version for Zone 1 Series 9475/

MODEL: 6DV-B. [2] TERMINAL BLOCK 0: None (Euro terminal block at the rear of indicator module)

ETD-BL-1T-OFF-CC- 10S

IECEx Certificate of Conformity

Inductive angle sensor with analog output Ri360P1-DSU35TC-ELi-Exi

Overload Relays. 3RB2 Solid-State Overload Relays. 3RB20, 3RB21 for standard applications. 5/48 Siemens LV Overview

Operating instructions AS-i SmartLine module AC3200 AC /00 06/2016

PROCESS AUTOMATION MANUAL. Universal Temperature Converter KCD2-UT2-(Ex)1 ISO9001

4 Remote I/O. Digital Output Module 8-Channel Version Series 9475/ from Rev. F

Cerabar S PMC71, PMP71, PMP ma HART, PROFIBUS PA, FOUNDATION Fieldbus

WG 20. The WG 20 achieves an extraordinarily. accuracy for hazardous-area. applications.

Inductive sensor NI3-EG08K-Y1-H1341

M-series Intrinsically Safe I/O

Inductive sensor BI5-EM18-Y1X-H1141

Assembly. Front view. LED yellow/red: Status output Ι/ Fault signal Function. Switch Power Rail

Safety instructions VEGATOR 121, 122

Segment Protector for Cabinet Installation R2-SP-IC* Features. Assembly. Function. Connection. Trunk, Ex na non-arcing. Spur.

MACX MCR-SL-(2)I-2)I-ILP(-SP)

YT-870 / 875 Series. Rotork YTC Limited VERSION 1.06

INTRINSICALLY SAFE Ex ia PSU TYPE AC36W

BACnet/IP Web Interface

MINI MCR-SL-PT100-UI-200

Operating instructions. Switching amplifier DN0210 DN / / 2015

MACX MCR-EX-SL-RPSSI-I(-SP)

Transcription:

Introduction To protect the signal lines of field devices and systems in the cabinet against lightning. Pepperl+Fuchs covers the complete range of Surge Protection Barriers. Housing types Depending on the location you have to protect, we offer 3 different versions of Surge Protection Barriers. DIN rail mount modules (K-LB-*.**) Compact housing, 12.5 mm wide Protection of field devices and control devices Single and dual channel versions Grounded versions for zener barrier applications 1 2 3 4 FS-LB-I 5 6 7 8 Figure 2 Surge protection K-LB-*.** Field mount modules (F*-LB-I) Screw in type for field devices Protection of field devices ½ NPT, M20 and PG13.5 threat versions Floating versions M20x15 FS-LB-I Figure 3 Surge protection F*-LB-I Figure 1 Various Surge Protection Barriers Plug-in modules (P-LB-*.*.*) Plug-in version for the 20 mm devices of the K-System Protection of K-System inputs For isolated barriers and signal conditioners Single and dual channel versions Figure 4 Surge protection P-LB-*.*.* 1

Mounting and grounding The correct installation of the Surge Protection Barrier (SPB) is very important. It must be ensured that the unprotected wiring does not influence the wiring on the protected side. Proper cable routing should ensure a sufficient cable distance between wires of the unprotected, earth connected and protected side. Depending on the mounting place, there are different possibilities for mounting and earthing. Topology To protect the electrical equipment in both the control room and the hazardous area, two Surge Protection Barriers must be integrated into the intrinsically safe circuit loop. Following the international standard EN 60079-14, intrinsically safe circuits can either be connected "at one point to the equipotential bonding system if this exists over the whole area in which the intrinsically safe circuits are installed" or "isolated from earth". International Standard EN 60079-14 states "if intrinsically safe apparatus (field devices, Surge Protection Barriers and intrinsically safe barriers) do not withstand the electrical strength test with at least 500 V from earth, a connection to earth at the apparatus is to be assumed". Option 1 Option 2 F*-LB-I P I + - K-LB-*.* K-LB-*.*G Zener Barrier Protected electrical equipment Protected field device Additional field housing Local earth Equipotential bonding (if required) Main system earth Remote earth Plant earth Figure 5 One point ground connection 2

DIN rail mount modules (K-LB-*.**) Unprotected Figure 6 DIN rail mount module grounding Protected Protection Unprotected signal loop Since lightning-induced signals show pulse characteristics, standard circuit breakers or fuses are not able to sufficiently protect the electrical equipment. It can also be used for protection against other sources causing transient voltages like devices changing voltages or currents during switching events or exhibiting a non-linear behavior. These other sources are energy storing inductive loads, such as transformers, motors and drives. They can induce high transient voltages and surge currents on conductors that can damage connected equipment. Each electronic device in the loop should be protected with a Surge Protection Barrier. Field mount modules (F*-LB-I) The screw-in F*-LB-I is screwed directly into the field device using the spare cable entry. Three wires are connected in parallel to the field device s signals and earth line. Input 24 V Terminal box Transmitter F*-LB-I GND Figure 9 Unprotected signal loop Figure 7 Field mount module grounding F*-LB-I Plug-in modules (P-LB-*.*.*) Protection of the field device Two options are available for the protection of the field device: Option 1 The standard DIN Rail mounted K-LB-*.** is located close to the field device. It should be placed within a field enclosure and mounted on a grounded rail. The SPB must be locally bonded to control the local potential between the signal cables and the structure. Option 2 The screw-in F*-LB-I is screwed directly into the field device using the spare cable entry. Three wires are connected in parallel to the field device s signals and earth line. This will ensure a line-to-line and line-to-earth protection. Figure 8 Plug-in module grounding 3

Option 2 Option 1 Safe area F*-LB-I Input 24 V K-LB-1.30 Additional field housing P-LB-*.*.* Isolated Barrier Figure 10 Protection of the field device Protection of control side (cabinet) Protection without isolation To protect the zener barrier, a non-isolated, separately mounted Surge Protection Barrier must be installed and connected to the intrinsically safe side of the zener barrier. The barrier s earth connection is made, following the described guidelines, to the main system earth in parallel to the equipment and zener barrier earth cable. K-LB-1.30G Safe area Zener Barrier Input 24 V Figure 13 Protection with isolation Model number description DIN rail mount modules. G Grounded 6 Rated voltage 6 V 30 Rated voltage 30 V 1 1-channel (2-wire protection) 2 2-channel (4-wire protection) LB Lightning barrier K DIN rail mount modules Figure 11 Protection without isolation Protection with isolation The entire intrinsically safe circuit is isolated from earth. The intrinsically safe barrier is an isolated barrier and no connection to the main system earth is necessary. To maintain the intrinsically safe measurement loop galvanically isolated from earth, an isolated Surge Protection Barrier must be installed at both ends of the loop. This must be close to the isolated barrier, connected to its intrinsically safe side in the safe area and close to the field device in the hazardous area, but outside Zone 0. Safe area Input 24 V Field mount modules I Intrinsic safety Ex "i" LB Lightning barrier FN Field mount modules with ½ NPT thread FP Field mount modules with PG13.5 thread FS Field mount modules with M20 x 1.5 thread Plug-in modules.. Protected terminals 1 1-channel Figure 12 K-LB-*.* Protection with isolation Isolated Barrier P 2 2-channel LB Lightning barrier Plug-in modules 4

Safety Information for K-LB-*.** DIN rail mount modules The highest ignition protection class to be reached is II 2 (1) G Ex ia IIC T6 Category Device group The corresponding data sheets, the Declaration of Conformity, the EC-Type Examination Certificate and applicable certificates (see data sheet) are an integral part of this document. Intended use Gas area Identification for availability of explosions Protection level Explosion protection identification Temperature class Explosion group Laws and regulations applicable to the usage or planned purpose of usage must be observed. Devices are only approved for proper usage in accordance with intended use. Improper handling will result in voiding of any warrantee or manufacturer's responsibility. Surge Protection Barriers are used as modules positioned upstream in the circuit from the corresponding electrical equipment. They make it possible to protect against overvoltages originating from various causes (lightning strikes, switching processes, etc.). This is achieved by diverting the transient current and limiting the voltage throughout the duration of the overvoltage surge. Various modules are available for protecting 2 or 4 conductors. Protection of operating personnel and the system is not ensured if the product is not used in accordance with its intended use. Intrinsic safety circuits that were operated with circuits of other types of protection may not be used as intrinsically safe circuits afterwards. Application Surge Protection Barriers themselves can be installed within the hazardous area of Zone 1. They can be used for intrinsically safe circuits up to Ex ia IIC. The ignition protection class is determined by the connected intrinsically safe circuit of the corresponding electrical equipment. Surge Protection Barriers are not used to separate intrinsically safe circuits from non-intrinsically safe circuits. Surge Protection Barriers must not be installed in dust Exzones. Installation and commissioning in connection with hazardous areas Commissioning and installation must be performed only by specialists who are trained specifically for this purpose. The quality of the ground is a significant precondition for problem-free overvoltage protection. Short connections and large cable cross-sections are basic requirements for effective protection. These requirements can be fulfilled through the use of appropriate accessories (see data sheets). Potential compensation must be set up for Surge Protection Barriers of types K-LB-*.*G along the intrinsically safe circuits inside and outside of the hazardous area Surge Protection Barriers modules are designed in the IP20 protection class in accordance with EN 60529 and must be protected against adverse environmental conditions such as splashed water or dirt beyond pollution degree 2. Depending on the ignition protection class, the circuits of Surge Protection Barriers may be directed in Zone 1 or 0. Special attention must be paid to a secure separation from all non-intrinsically safe circuits in this context. A shortest path distance of at least 50 mm must be maintained between intrinsically safe and non-intrinsically safe conducting terminal blocks during assembly. The ignition protection class is determined by the connected intrinsically safe circuit of the corresponding electrical equipment. The installation of the intrinsically safe circuits is to be conducted in accordance with the relevant installation regulations. The respective maximum values of the field device, the Surge Protection Barriers and the corresponding electrical equipment as defined by explosion protection must be observed for interconnecting with intrinsically safe electrical equipment (proof of intrinsic safety). EN 60079-14/ IEC 60079-14 must be observed (where appropriate). 5

The EC-Type Examination Certificates or standard certificates/approvals should be observed. It is especially important to observe the "special conditions" if these are included in the certificates. The use of this device must not change the ignition protection category of the supplying circuit. Thus, for example, ib circuits must not enter Zone 0, even if they are controlled via this device unless otherwise stated in the related approval. Repair and maintenance The transfer characteristics of the devices remain stable over long periods of time. This eliminates the need for regular adjustment. Maintenance is not required. Fault elimination No changes can be made to devices that are operated in hazardous areas. Repairs on the device are not allowed. Isolation coordinates for devices with Ex-certificate in accordance with EN 50020 and EN 60079-11 The devices are assessed for pollution degree 2 and overvoltage category II according to EN 50178. For additional details, see data sheets. Ambient conditions Ambient temperature -30 C to 60 C (243 K to 333 K) Exceptions see data sheets. Storage temperature -30 C to 80 C (243 K to 353 K) Relative humidity max. 75 % without moisture condensation 6

Safety Information for F*-LB-I field mount modules The highest ignition protection class to be reached is II 2 G Ex ia IIC T6 Category The corresponding data sheets, the Declaration of Conformity, the EC-Type Examination Certificate and applicable certificates (see data sheet) are an integral part of this document. Intended use Laws and regulations applicable to the usage or planned purpose of usage must be observed. Devices are only approved for proper usage in accordance with intended use. Improper handling will result in voiding of any warrantee or manufacturer's responsibility. Surge Protection Barriers are used as protective modules for intrinsically safe field devices and the corresponding electrical equipment. They make it possible to protect against overvoltages originating from various causes (lightning strikes, switching processes, etc.). This is achieved by diverting the transient current and limiting the voltage throughout the duration of the overvoltage surge. Protection of operating personnel and the system is not ensured if the product is not used in accordance with its intended use. Intrinsic safety circuits that were operated with circuits of other types of protection may not be used as intrinsically safe circuits afterwards. Application Gas area Device group Identification for availability of explosions Protection level Explosion group Explosion protection identification Temperature class Surge Protection Barriers themselves can be installed within the hazardous area of Zone 1. They can be used for intrinsically safe circuits up to Ex ia IIC. The ignition protection class is determined by the connected intrinsically safe circuit of the corresponding electrical equipment. Surge Protection Barriers must not be installed in dust Exzones. Installation and commissioning in connection with hazardous areas Commissioning and installation must be performed only by specialists who are trained specifically for this purpose. The quality of the ground is a significant precondition for problem-free overvoltage protection. Short connections and large cable cross-sections are basic requirements for effective protection. Depending on the ignition protection class, the circuits of Surge Protection Barriers may be directed in Zone 1 or 0. Special attention must be paid to a secure separation from all non-intrinsically safe circuits in this context. A shortest path distance of at least 50 mm must be maintained between intrinsically safe and non-intrinsically safe conducting terminal blocks during assembly. The ignition protection class is determined by the connected intrinsically safe circuit of the corresponding electrical equipment. The installation of the intrinsically safe circuits is to be conducted in accordance with the relevant installation regulations. The respective maximum values of the field device, the Surge Protection Barriers and the corresponding electrical equipment as defined by explosion protection must be observed for interconnecting with intrinsically safe electrical equipment (proof of intrinsic safety). EN 60079-14/ IEC 60079-14 must be observed (where appropriate). The EC-Type Examination Certificates or standard certificates/approvals should be observed. It is especially important to observe the "special conditions" if these are included in the certificates. The use of this device must not change the ignition protection category of the supplying circuit. Thus, for example, ib circuits must not enter Zone 0, even if they are controlled via this device unless otherwise stated in the related approval. Repair and maintenance The transfer characteristics of the devices remain stable over long periods of time. This eliminates the need for regular adjustment. Maintenance is not required. Fault elimination No changes can be made to devices that are operated in hazardous areas. Repairs on the device are not allowed. Ambient conditions Ambient temperature -30 C to 60 C (243 K to 333 K) Exceptions see data sheets. Storage temperature -30 C to 80 C (243 K to 353 K) Relative humidity max. 75 % without moisture condensation 7

Safety Information for P-LB-*.*.* plug-in modules The corresponding data sheets, the Declaration of Conformity, the EC-Type Examination Certificate and applicable certificates (see data sheet) are an integral part of this document. Intended use Laws and regulations applicable to the usage or planned purpose of usage must be observed. Devices are only approved for proper usage in accordance with intended use. Improper handling will result in voiding of any warrantee or manufacturer's responsibility. Plug-in terminal modules are used as modules positioned upstream in the circuit from the corresponding electrical equipment. They make it possible to protect against overvoltages originating from various causes (lightning strikes, switching processes, etc.). This is achieved by diverting the transient current and limiting the voltage throughout the duration of the overvoltage surge. Various modules are available for protecting 2, 3, 4 or 6 conductors. The assignment of input connections of plug-in terminal modules/intrinsically safe equipment (binary or analog signals) corresponds to that of the following related equipment (see the corresponding data sheets). Plug-in terminal modules should only be used in combination with a device of the K-System. Protection of operating personnel and the system is not ensured if the product is not used in accordance with its intended use. Intrinsic safety circuits that were operated with circuits of other types of protection may not be used as intrinsically safe circuits afterwards. Application Plug-in terminal modules can be installed within the hazardous area of Zone 2/Div. 2. They can be used for intrinsically safe circuits up to Ex ia IIC. The ignition protection class is determined by the connected intrinsically safe circuit of the corresponding electrical equipment. Plug-in terminal modules are not used to separate intrinsically safe circuits from non-intrinsically safe circuits. Plug-in terminal modules must not be installed in dust Exzones. Installation and commissioning in connection with hazardous areas Commissioning and installation must be performed only by specialists who are trained specifically for this purpose. The quality of the ground is a significant precondition for problem-free overvoltage protection. Short connections and large cable cross-sections are basic requirements for effective protection. These requirements can be fulfilled through the use of appropriate accessories (see data sheets). Plug-in terminal modules are designed in the IP20 protection class in accordance with EN 60529 and must be accordingly protected against adverse environmental conditions such as splashed water or dirt beyond pollution degree 2. Plug-in terminal modules can be installed inside the hazardous area of Zone 2/Div. 2. Since plug-in terminal modules are always used in combination with devices of the K-System, the devices of the K-System must, in this case, be suitable for use in Zone 2/Div. 2. The devices of the K-System must then be installed only in Zone 2/Div. 2 if a corresponding Declaration of Conformity for a named location or a manufacturer's Declaration of Conformity is present. For information on whether this condition has been met, please refer to the data sheets for the devices of the K-System. The instruction manual, the Declaration of Conformity of a named location or the manufacturer's Declaration of Conformity of devices of the K-System and the information in them must be followed. Depending on the ignition protection class, the circuits of plugin terminal modules may be directed in Zone 1 or 0. Special attention must be paid to a secure separation from all nonintrinsically safe circuits in this context. A shortest path distance of at least 50 mm must be maintained between intrinsically safe and non-intrinsically safe conducting terminal blocks during assembly. The ignition protection class is determined by the connected intrinsically safe circuit of the corresponding electrical equipment. The installation of the intrinsically safe circuits is to be conducted in accordance with the relevant installation regulations. The respective maximum values of the field device, the plug-in terminal modules and the corresponding electrical equipment as defined by explosion protection must be observed for interconnecting with intrinsically safe electrical equipment (proof of intrinsic safety). EN 60079-14/ IEC 60079-14 must be observed (where appropriate). 8

The EC-Type Examination Certificates or standard certificates/approvals should be observed. It is especially important to observe the "special conditions" if these are included in the certificates. The terminal modules must be installed in such a way that they are protected from electrostatic charge. The use of this device must not change the ignition protection category of the supplying circuit. Thus, for example, ib circuits must not enter Zone 0, even if they are controlled via this device unless otherwise stated in the related approval. Repair and maintenance The transfer characteristics of the devices remain stable over long periods of time. This eliminates the need for regular adjustment. Maintenance is not required. Fault elimination No changes can be made to devices that are operated in hazardous areas. Repairs on the device are not allowed. Isolation coordinates for devices with Ex-certificate in accordance with EN 50020 and EN 60079-11 The devices are assessed for pollution degree 2 and overvoltage category II according to EN 50178. Ambient conditions Ambient temperature -20 C to 60 C (253 K to 333 K) Storage temperature -25 C to 70 C (248 K to 343 K) Relative humidity max. 75 % without moisture condensation Technical data For details, see data sheets. 9