Surge Protection Devices Type 1+2

Similar documents
Surge Protection Devices and Surge Protection Kit

Technical features OVR Surge Protective Devices Type 1 & Type 1+2

Surge Protection Devices Ex9UE2

Modular surge protective devices

Type of surge arrester

Page 14-4 Page Page 14-4 SURGE PROTECTION DEVICES TYPE 2 VERSIONS WITH PLUG-IN CARTRIDGE 1P, 1P+N, 2P, 3P, 3P+N, 4P

Low voltage. Acti 9. the efficiency you deserve. Catalogue 03/2016

PRF1 12.5r/PRF1 Master/ PRD1 25r/PRD1 Master Type 1 and 2 LV surge arresters

CONTA-ELECTRONICS. CONTA-PROTECT overvoltage protection

voltage surge protectors low voltage type 1 (class I / B) voltage surge protectors low voltage type 2 (class II / C) Distribution board protection

Equipment protection

US Catalog March Surge protective devices (SPDs) UL range

3 Design of the electrical installation protection system

wietap wietap Overvoltage Protection Tensions running high

2 Principle of lightning protection

SPM Series Plug-in Surge Protector Type 2/3 (Test Class II/III) Single & Three Phase Surge Arresters

Overvoltage Protection Devices

ETITEC - Lightning and Surge Arresters

SPM Series Plug-in Surge Protection

MULTI-POLE PHOTOVOLTAIC SYSTEMS. COMPACT and MODULAR Housing

Modular surge protective devices (SPDs) Cat. Nos :

Overvoltage Protection Devices

Overvoltage Protection Devices

mcbs, EQUIPMENT NEW PRODUCTS 2014 Voltage surge protectors & other control and signalling devices Time & light sensitive switches

Modular surge protective devices (SPDs)

SURGE PROTECTIVE DEVICES

SPM Series. Plug-in Surge Protection

Modular surge protective devices (SPDs)

Lightning and Surge Arresters

Surge Protection for Low Voltage Power Systems

Miniature. Circuit Breakers. reliable solutions for protection of installations against over-current phenomenon. Advantages for you : Technical data :

Overvoltage Protection Devices

8 PHOENIX CONTACT Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA

PRACTICAL EXAMPLES OF OVERVOLTAGE PROTECTION

SURGE PROTECTION LIGHTNING & EARTHING EQUIPMENT

Surge & Filter Protection Addressing your industrial power quality needs.

Leutron. Lightningand. Surge Protection for Power Net Systems (SPD) with EnerPro Combi-Devices. Seite 0 von14

Overvoltage Protection Devices

ENGR. MARITES R. PANGILINAN, P.E.E.

Datasheet SPD II 1 Surge Protectors for AC Power Distribution SPD II PV Surge Protectors for Photovoltaic Installations

OPTIMISED LUMINAIRE PROTECTION

VAL-CP-1S-175. Extract from the online catalog. Order No.:

R3&A Limited, Cobourg, ON

SPD Catalogue. SPD Catalogue. for AC applications

PROTEC Z LV the universal solution for transient switching protection for LV motors, generators, transformer LV secundaries, VSD and UPS equipment

TT-ST-M-2-PE-24DC. Extract from the online catalog. Order No.:

Cirprotec. Specialists in Lightning and Surge Protection for Photovoltaic Systems. Includes new plug-in SPD range and insulation monitoring device

Surge Protective Device

Lightning and Surge Protection of Photovoltaic Installations. Leutron GmbH 2013 Leinfelden-Echterdingen, Germany

Overvoltage Protection

Installation / Control Technique

DIN Series MINIATURE CIRCUIT BREAKERS, RESIDUAL CURRENT CIRCUIT BREAKERS. Introducing the DIN Series High-quality, high-performance circuit breakers

Surge Protection for Surveillance Systems

PT 3-PB-ST. Extract from the online catalog. Order No.:

Lightning & Surge Protection

02/11/2015

OPTIMISED LUMINAIRE PROTECTION

Reliability in Surge Protection. Photovoltaic Systems.

VAL-CP-3S-350. Extract from the online catalog. Order No.:

Jtec 10kA Miniature Circuit Breaker

08/07/2015

Coordination of Surge protection devices

Surge Protective Device

LED Driver Linear / area fixed output

NEW. Datasheet. SPD II and SPD III AC Surge Protector

OTEC Miniature Circuit Breakers (MCB) OTEC Miniature Circuit Breakers (MCB) OTEC Miniature Circuit Breakers (MCB) Areas of Application

PT 2-PE/S- 24AC-ST. Extract from the online catalog. Order No.:

Surge protection for frequency converters

Autoprotected Surge Arresters New OVR Plus range

PT 2X2-HF-24 DC-ST. Extract from the online catalog. Order No.:

LED Driver Linear / area fixed output

MDSP-Series 90kA, 150kA, 300kA Modular Distribution Surge Protector Type 2 Class II Surge Arrester

Lightning Current Equipotential Bonding SPDs

BS th Edition wiring regulations Furse overview

Technical Data. Circuit Protection - Surge Protection Devices. Ver 1.0 CUSPD1110. Brief product description:

LED Driver Linear / area fixed output

Motor Controllers AC Semiconductor Motor Controller Type RSHR MIDI

M ISCELLANEOUS A CCESSORIES O BSTRUCTIONS LIGHTS MISCELLANEOUS ACCESSORIES OBSTRUCTION LIGHTS

Remote contact signaling available. visual status indication

Datasheet - SRB 402EM-24V

Monitoring technique. VARIMETER Voltage relay MK 9064N, MH 9064

PT 2X2-24DC-ST. Extract from the online catalog. Order No.:

Protection of PHOTOVOLTAIC SYSTEMS against LIGHTNING and OVERVOLTAGE. Surge Protection Device

Motor Controllers AC Semiconductor Motor Controller Type RSHR MIDI

BOX TRANSDUCER SMALL SIZED AC TRANSDUCER 90 SERIES

PT 5-HF- 5 DC-ST. Extract from the online catalog. Order No.:

NEW surge protective devices

Power Supply, Primary Switch Mode, Narrow Design MINI-PS AC/24DC/1

RE7RB13MW adjustable off-delay timing relay s V AC DC - 2OC

VEO. V2PF480Y/277VSY01 Art.Nr.: V2PF480Y/277VSY01P Art.Nr.: TECHNICAL DATA

02/11/2015

DBPApplication. PD Devices Ltd. Unit 1, Old Station Yard, South Brent, Devon. TQ10 9AL (0)

Photovoltaic System Components Connection And Protection

TT-2-PE-M-24DC. Extract from the online catalog. Order No.:

Surge protection solutions

Technology Live Workshop

Section 4 Ground-Fault Protection Devices

Building Surge Protection Information Pack

Control elements. Fine adjustment. Status indication. 24 V DC typ. 0,25 W / 0,25 VA. 24 V DC typ. 0,03 W / 0,09 VA. 0,15 3 s. 0,5 10 h.

Electronic timer CT-SDD.22 Star-delta change-over with 2 n/o contacts

Transcription:

Surge Protection Devices Type 1+2 Description The combined surge protection devices offer as an all-in-one solution lightning and surge-voltage in one device. They are in accordance with the requirement class type 1. 3 versions available, with or without auxiliary contact: SP800 for TC-etworks, 75kA (lighting impulse current) SP801 for TS-etworks, 100kA (lighting impulse current) SP802 for TT-etworks, 100kA (lighting impulse current) Product features ightning and surge-voltage protection in one device, Conforming to 61643-11, requirement class type 1+2, replaceable plug-in modules, integrated fault indicator in the plug-in modules, SPDs with separate auxiliary contact. Description Characteristics o of poles Cat. ref. Surge protection devices, with auxiliary contact 3 SP800R type 1+2, for TC-etworks without auxiliary contact 3 SP800 SP800R Surge protection devices, with auxiliary contact 4 SP801R type 1+2, for TS-etworks without auxiliary contact 4 SP801 Surge protection devices, with auxiliary contact 4 SP802R type 1+2, for TT-etworks without auxiliary contact 4 SP802 SP801 Cartridges phase - 25kA SP080 for SP8xxx neutral - 25kA class 1 for SP802 and SP802R SP080 SP080 4.28

Surge Protection Devices Type 2 Description SPD s protect electrical and electronic equipment against transients, originating from lightning, switching of transformers, lighting and motors. These transients can cause premature ageing of equipment, downtime, or complete destruction of electronic components and materials. SPDs are strongly recommended in installations that are exposed to transients, to protect sensitive and expensive electrical equipment such as TV, video, washing machines, Hi-Fi, PC, alarm etc. The choice of SPD depends on a number of criteria such as: The exposure of the building to transients. The sensitivity and value of the electrical equipment that requires protection. arthing system evel of protection The range of SPDs is separated into 2 types of protection: 1. Main protection - class 2 SPDs with higher discharge current (Imax 8/20), to evacuate as much of the transient to earth as possible, 2. Fine protection - class 2 + 3 SPDs with low voltage protection level (Up 1,2kV), to cut-down the transient surge as low as possible to protect very sensitive equipment. Technical data Complies with 61643-U Reserve Status Indicator (R versions) nd of ife Indicator (D versions) Auxiliary contact for remote signalling (R versions only) 230V~ 1A 12V... 10mA Installation and Connection The main protection SPDs are installed directly after the main incoming switch or RCCB (type S). SPDs can be used in any supply system e.g TCS, TS, TT. Options: Spare cartridges. Connected in to the equipment to be protected. Protection is assured in both common and differential modes. Description Characteristics Cat. ref. Single pole 40kA, 2kV, class 2 SP140D surge protection devices Un: 230/400V 50/60Hz Protection Devices Double pole 65kA, 1,3kV, class 2 SP265R surge protection devices Un: 230/400V 50/60Hz SP240R SP240D SP240D SP215R SP215D Four pole 65kA, 1,5kV, class 2 SP465R surge protection devices Un: 230/400V 50/60Hz SP440R SP440R SP440D SP415R SP415D 4.29

Surge Protection Devices Type 2 Spare cartridges These cartridges replace the cartridge in the main SPD. They allow simple replacement without the need to cut-off the power supply. Cartridges are available for all discharge currents (40kA and 15kA) with and without condition indication. A keying system exists to prevent a line cartridge being interchanged by mistake with a neutral one and vice versa. eutral cartridges have a discharge current of 65kA. For Phase: SP140D = SP040D SP215D = SP015D SP415D = SP015D SP215R = SP015R SP415R = SP015R For eutral / arth SP215D = SP040 SP415D = SP040 SP215R = SP040 SP415R = SP040 Description Characteristics Cat. ref. Spare cartridge phase 65kA, 275V AC SP065R for SPx65R SP040C 40kA, 440V AC for SP140C 40kA, 275V AC for SPx40R 40kA, 275V AC for SPx40D 15kA, 275V AC for SPx40R 15kA, 275V AC for SPx40D SP040C SP040R SP040D SP015R SP015D Spare cartridge neutral 65kA, 255V AC SP065 for SPx65R 40kA, 255V AC for SPx40x and SPx15x SP040 SP040 Cartridge for photovoltaic polarized +/- for SPV325 SPV025 SPDs photovoltaic Ucpv 1000V DC earth for SPV325 SPV025 SPV025 4.30

Surge Protection Devices with ow Voltage Protection evel SPDs with low let through voltage levels To protect very sensitive electronic equipment. This ine protection complements the main protection and can protect 1 or several electronic devices. Optimal coordination is obtained when cascaded with a main protection device (lower Up). Discharge current: Imax. 8kA (8/20 wave) A green D on the front face indicates the status of the SPD SP208S, connected in series with the equipment that needs to be protected (with a maximum line current of 16A). Protection is assured in both common and differential modes. Terminal blocks, & rigid conductor: 10mm 2 lexible conductor: 6mm 2 Description Characteristics Width in z Cat. ref. Double pole ine protection 8kA, 1,2kV, class 2 2 SP208S surge protection devices with light indicator Uc: 230/400V 50/60Hz Four pole ine protection 8kA, 1,2kV, class 2 3 SP408S surge protection devices with light indicator Uc: 230/400V 50/60Hz SP208S Protection Devices Surge Protection Devices for Telephone ines Description Characteristics Width in z Cat. ref. SPD for analogical Un: 130V, Up: 600V AC 1,5 SP505 phone line SPD for numerical Un: 40V, Up: 600V AC 1,5 SP504 phone line SP505 4.31

Surge Protection Devices Type 1+2 SPD references SP800 SP801 SP802 Standards / approval 61643-11 61643-11 61643-11 // P /// P /// P P Type / Class T1/ I / B T1/ I / B T1/ I / B Installation of SPD in in in arthing system T-C T-S TT Protection mode common common common and differential ominal voltage (Un) 230/400 V AC 230/400 V AC 230/400 V AC Max. continuous operating voltage (Uc) 255 V AC 255 V AC 255 V AC Voltage protection level (Up) 1,5 kv 1,5 kv 1,5 kv Temporary overvoltage (Ut) 440 V / 5 s 440 V / 5 s 440 V / 5 s 1200 V / 200 ms ominal current I () 315 Aeff 315 Aeff 315 Aeff ominal current (I (- ) 125 Aeff 125 Aeff 125 Aeff Disconnection value (Ii) 50 kaeff 50 kaeff 50 ka 100 ka Discharge current capacity (8/20) nominal current (In) 75 ka 100 ka 25 ka 100 ka Shock current (10/350) (Iimp) 75 ka 100 ka 25 ka 100 ka Residual current IP 100 µa 100 µa 100 µa Max. upstream protection - fuse Max. upstream protection - MCB Max. short-circuit resistance with max. upstream protection - fuse Max. short-circuit resistance with max. upstream protection - MCB 125 A g/gg in series or 315 A in 125 A in series or 160 A in curve C 125 A g/gg in series or 315 A in 125 A in series or 160 A in curve C 125 A g/gg in series or 315 A in 50 ka eff ac 50 ka eff ac 25 ka eff ac 50 ka eff ac 50 ka eff ac 25 ka eff ac Temps de réponse (ta) 100 ns 100 ns 100 ns 125 A in series or 160 A in curve C Working temperature -40 C to +60 C -40 C to +60 C -40 C to +60 C Indication (disconnection device) green - red light on,, green - red light on,,, green - red light on,,, min.,,, P - max.,,, P max.,,, P max.,,, P 10 mm 2 rigid / lexible 10 mm 2 rigid / lexible 10 mm 2 rigid / lexible 35 mm 2 lexible 25 mm 2 lexible 35 mm 2 lexible 25 mm 2 lexible Terminals tightening torque 7,0 m 7,0 m 7,0 m 35 mm 2 lexible 25 mm 2 lexible Mounting on DI rail 35 mm ( 60715) DI rail 35 mm ( 60715) DI rail 35mm, conform to 60715 Case material thermoplastic, grey color, U 94V-0 thermoplastic, grey color, U 94V-0 thermoplastic, grey color, U 94V-0 Degree of protection IP20 IP20 IP20 Size 6 z, DI 43880 6 z, DI 43880 8 z, DI 43880 Weight 970 g 1260 g 1272 g Approval VD VD VD Auxiliary contact references SP800R = SP800 w/ aux. contact SP801R = SP801 w/ aux. contact SP802R = SP802 w/ aux. contact Contact type changeover changeover changeover lectrical characteristics (Un/In) AC: 250V/0,5A AC: 250V/0,5A AC: 250V/0,5A DC: 250V/0,1A ; 125V/0,2A ; 75V/0,5A DC: 250V/0,1A ; 125V/0,2A ; 75V/0,5A DC: 250V/0,1A ; 125V/0,2A ; 75V/0,5A Min. connection capacity 0,25 mm 2 rigid / lexible 0,25 mm 2 rigid / lexible 0,25 mm 2 rigid / lexible Max. connection capacity 1,5 mm 2 multi-wired / lexible 1,5 mm 2 multi-wired / lexible 1,5 mm 2 multi-wired / lexible Installation in T-C Installation in T-S Installation in TT F F I ' ' ' ' ' ' ' ' ' P P ' ' P P S2 S2 S2 ' ' ' ' ' ' ' ' ' ' ' SP802 - SP802R SP800 - SP800R SP801 - SP801R P P P P S3 S3 S3 4.32

Surge Protection Device Type 2 & Fine Protection Class II - Overvoltage protection High Medium Fine Reference SP140D SP215D SP215R SP415D SP415R SP208S Installation exposure level (risk) high medium medium medium medium low Installation of SPD series umber of poles 1P 1P+ 1P+ 3P+ 3P+ 1P+ umber of modules 1 2 2 4 4 2 ominal current - - - - - - ominal voltage Un (V) 230 230 230 400 400 230/400 Frequency (Hz) 50/60 50/60 50/60 50/60 50/60 50/60 Operating temperature range -40 C to +60 C -40 C to +60 C -40 C to +60 C -40 C to +60 C -40 C to +60 C -40 C to +60 C Storage temperature range -40 C to +70 C -40 C to +70 C -40 C to +70 C -40 C to +70 C -40 C to +70 C -40 C to +70 C Max. continuous operating voltage Uc (V) common mode 275 275 275 275 275 440 differential mode - - - - - 255 Voltage protection level Up (kv) common mode 1,2 differential mode 1,2 1,0 1,0 1,0 1,0 1,0 Discharge current wave 8/20 µs (ka) nominal current In 15 5 5 5 5 2 maximum current Imax 40 15 15 15 15 8 Short circuit withstand with max. backup fuse or MCB 20kA 10kA 10kA 10kA 10kA 6A Protection Devices max. backup fuse 25A 10A 10A 10A 10A 25A backup MCB (C curve) 25A 25A 25A 25A 25A 25A nd of life indication (fault indication) 1. three stage indication - green, green/red, red (R versions) 2. basic indication - green/red (D versions) 3. green D is on when SPD is working yes /A yes /A yes /A /A yes /A yes /A /A /A /A /A /A /A yes Applications industrial and commercial buildings yes yes yes yes yes yes domestic buildings yes yes yes yes yes yes Imax In Up Uc Uoc Isc Un MOV SPD The maximum value of current that the SPD can withstand and remain operational. The nominal value of current that the SPD can withstand at least 20 times and still be serviceable. The residual voltage that is measured across the terminal of the SPD when In is applied. The maximum voltage which may be continuously applied to the SPD without conducting. Open circuit voltage under test conditions. Short circuit current under test conditions. The nominal rated voltage of the installation Metal Oxide Varistor Surge Protective Device 4.33

Surge Protection Devices How to choose your surge protection device The choice of surge protection device depends on your supply arrangements and level of protection required. arthing system Type of protection connection Products to be used in a Single phase installation Three phase installation T-C T-C-S (P-M-) transient voltage surges (8/20ms) main protection Imax = 40kA or 15kA (depending on selection) ine protection Up < 1kV SP140D SP208S 1xSP415D/SP415R T-S TT transient voltage surges (8/20ms) main protection Imax = 15kA Imax = 15kA ine protection Up < 1kV SP215D/SP215R SP208S 1xSP415D/SP415R Connections SP140D SP265R SP415D/R SP208S 4.34