C E R T I F I C A T E O F C O M P L I A N C E

Similar documents
C E R T I F I C A T E O F C O M P L I A N C E

Siemens AG I IA CE CP R&D-VI 4 WERNER-VON-SIEMENS-STRASSE AMBERG, GERMANY

CERTIFICATE OF COMPLIANCE

Certificate of Compliance

File E Project 00ME December 18, 2000 REPORT COMBINATION CONTROLLERS. Siemens AG Amberg, Germany

CERTIFICATE OF COMPLIANCE

CERTIFICATE OF COMPLIANCE

OVERLOAD RELAYS POWER & ACTUATION PROVEN. series

1.1. Contactors and Starters... Contents Description Relays and Timers... Miniature Controls... Manual Motor Protectors. XT IEC Power Control

Controls Enclosed Non-Combination Starters - PESW Series

EU Declaration of Conformity

C E R T I F I C A T E O F C O M P L I A N C E

Bulletin 1489 Circuit Breakers. Selection Guide

TeSys IEC Contactors and Overload Relays

SIGUARD Safety Combinations and Safe Load Feeders. safety INTEGRATED

FAZ Supplementary Protectors, FAZ Miniature Circuit Breakers, P2 Disconnect Switches Overview

Motor protection relays

Large Frame IEC Contactors

C E R T I F I C A T E O F C O M P L I A N C E

Overload Relays. 3RB2 Solid-State Overload Relays. 3RB20, 3RB21 for standard applications. 5/48 Siemens LV Overview

1. Coordination of series-rated devices is permitted where indicated on Drawings.

Motor protection circuit breakers

194E FA 32 E P11 P11 6

Protection Equipment

Cert.Record No _0_000, Class No , DQD No 557 Rev SUPPLEMENTARY PROTECTORS COMPONENT ACCEPTANCE PROGRAM

MULTI 9 System Catalog UL Recognized NC100H Supplementary Protectors

3RM1 Hybrid Starters 6SIRIUS. contents. Industrial Controls Product Catalog 2017

Miniature Circuit Breakers and Supplementary Protectors. Contents

Fast Bus Busbar System

Complete UL/CSA Disconnect Switch Kits

Load Feeders, Motor Starters and Soft Starters

Fast Bus Fast Bus Busbar System

Issued February DATA SHEET 5SX2 MCB. Based on Siemens Industrial Control Catalog

C E R T I F I C A T E O F C O M P L I A N C E

Solid-State Switching Devices

SECTION SWITCHBOARDS

low voltage GLOBAL CATALOGUE RANGE Motor Control Contactors - Thermal Overload Relay s - Manual Motor Starters

Industrial Controls. Protection Devices. Gerätehandbuch. Answers for industry. Edition 09/2014

Load Feeders and Motor Starters for Use in the Control Cabinet

Siemens AG RA6 Fuseless Compact Starters. Catalog News LV 1 N April 2008 SIRIUS.

SIRIUS Overload Relays. SIRIUS 3RB24 Solid-State Overload Relays with Complete Starter Functionality via IO-Link

RiLine Compact The smart power distribution system

Mini Contactors & Overloads

3RA13, 3RA14 Contactor Assemblies

Industrial Controls Product Catalog RA64 / 3RA65 up to 32 A for mounting rail, surface,

Switch Disconnectors, Main and EMERGENCY-STOP Switches

EU Declaration of Conformity

Equipment Short-Circuit Current Rating and Available Fault Current

4 COMBINATION SIRIUS. SIRIUS 3RA6 Compact Starters 4/2. General data

Disconnect Switches. Safe Switching and Disconnecting

MG24434 Supplementary Protector SUPPLEMENTARY PROTECTOR, 240VAC, 16A, CIRCUIT BREAKER TYPE: STANDARD

SECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS

Motor-protective circuit-breaker, 3p, Ir=16-25A, screw connection. Product range PKZM4 motor protective circuit-breakers up to 65 A

MOTOR PROTECTION CIRCUIT BREAKERS

Sentron 3VT circuit breakers Simply Smart: First choice for power distribution

MULTI 9 System Catalog UL Recognized C60N Supplementary Protectors

UL 508A Industrial Control Panels Eaton. All Rights Reserved.

Monitoring Relays. SIRIUS 3UG Monitoring Relays for Stand-Alone Installation. Line monitoring. 8/62 Siemens IC Overview

SIRIUS modular system

UL 489 DIN rail branch circuit breakers

IEC Power Control Contactors and Contactor Assemblies

EU Declaration of Conformity

Contactors and Contactor Assemblies

C E R T I F I C A T E O F C O M P L I A N C E

sirius Switching. Protecting. Starting. SIRIUS Product Overview

UL 489 DIN Rail Miniature Circuit Breakers

EU Declaration of Conformity

1.3. Miniature Circuit Breakers and Supplementary Protectors. Contents. WMZS Circuit Breaker. UL 1077 DIN Rail Supplementary Protectors

EU Declaration of Conformity

MOTOR & CIRCUIT PROTECTION

SIRIUS 3RB24 Solid-State Overload Relays with Complete Starter Functionality via IO-Link

Cert.Record No _C_000, Class No , DQD No 548 Rev

IMS Control & EPR, We keep your motors running ABB s new control & protection devices up to 18.5 kw / 20 hp

UL 489 Cable-In / Cable-Out Branch Circuit Breaker

1 Installation of accessories in molded case switches requires dummy trip; see page. Breaker/Switch Type TQD/TJD

WMS SUPPLEMENTARY PROTECTORS

C E R T I F I C A T E O F C O M P L I A N C E

Solid-State Contactors

1510 MOTOR CONTROLLERS

TeSys contactors From 115 to 2750 A

Jtec 10kA Miniature Circuit Breaker

Table of Specifications

Description Basic devices with positive operation contacts. Standards IEC/EN 60947, EN , VDE 0660, UL, CSA

For Efficiency and Reliability in the Control Cabinet. The SIRIUS 3RA6 Compact Starter SIRIUS. Answers for industry.

Micro Contactor MA Series

29 $ Manual Motor Starters FREESHIPPING. MOTOR CONTROLS 25. Features: MMS-32H Frame. MMS-63H Frame.

Go to:

UL 489 DIN Rail Miniature Circuit Breakers

PowerPact Q-Frame Molded Case Circuit Breakers and Switches (Types QB, QD, QG and QJ)

60103 Circuit Breaker

CERTIFICATE OF COMPLIANCE

C E R T I F I C A T E O F C O M P L I A N C E

Applying branch circuit breakers and supplementary protectors in North America

Applying branch circuit breakers and supplementary protectors in North America

Max. Back-up fuse [A] 50 ka, 690V AC 5 ka, 600V AC IEC/EN Coordination Type 1 Type 2

24973 Circuit Breaker MINIATURE CIRCUIT BREAKER, 440VAC, 10A, CIRCUIT BREAKER TYPE: STANDARD

IEC Contactors. Auxiliary Contact Blocks GENERAL

The City of Winnipeg Dry Type Transformers up to 600 V Primary Section Bid Opportunity No Page 1 of 2

NC2 Contactor, 115~630A. 1. General. 2. Type Designation. 3. Terminal Connection. Cabling(Cu) Cable 2. Tightening torque (N m) Screw size

Allen-Bradley Bulletin 100 Contactors

Transcription:

Issued to: This is to certify that representative samples of SIEMENS AG DF CP R&D VC 2 WERNER-VON-SIEMENS-STRASSE 48 92224 AMBERG, GERMANY MOTOR CONTROLLERS, MANUAL (See following page for additional information.) Have been investigated by UL in accordance with the Standard(s) indicated on this Certificate. Standard(s) for Safety: Additional Information: ANSI/UL 60947-1, "Low-Voltage Switchgear and Controlgear - Part 1: General Rules," and ANSI/UL 60947-4-1, "Low-Voltage Switchgear and Controlgear - Part 4-1: Contactors and Motor-Starters - Electromechanical Contactors and Motor-Starters." CAN/CSA-C22.2 No. 60947-1 (2013), "Low-Voltage Switchgear and Controlgear - Part 1: General Rules," and CAN/CSA-C22.2 No. 60947-4-1 (2014), "Low-Voltage Switchgear and Controlgear - Part 4-1: Contactors and Motor-Starters - Electromechanical Contactors and Motor-Starters." See the UL Online Certifications Directory at www.ul.com/database for additional information Only those products bearing the UL Certification Mark should be considered as being covered by UL's Certification and Follow-Up Service. Look for the UL Certification Mark on the product. Any information and documentation involving UL Mark services are provided on behalf of (UL) or any authorized licensee of UL. For questions, please Page 1 of 11

This is to certify that representative samples of the product as specified on this certificate were tested according to the current UL requirements. Products Covered: USL, CNL - Type Nos. 3RV20, 3RV21, 3RV23 or 3RV24, followed by 11, 21 or 23, followed by -0A, - 0B, -0C, -0D, -0E, -0F, -0G, -0H, -0J, -0K, -1A, -1B, -1C, -1D, -1E, -1F, -1G, -1H, -1J, -1K, -4A, -4B, - 4C, -4D, -4E, -4F, -4N or -4P followed by A or C, followed by 1, 2 or 4, followed by 0, 1, 2, 3, 4 or 5. May be followed by additional numbers and letters for manufacturers use. Accessory Terminal Cover Type No. 3RV2928-4AA00. General: These devices are open type 3-pole manual motor controllers for starting and stopping motors which may be connected directly across the line. They are adjusted over a small range as indicated in the setting range table. They are provided with integral ambient compensated, non-replaceable thermal trip features and are suitable for providing overload protection and motor disconnect. The trip current is 125 percent of the FLA shown on dial. Line or load side of the main terminals may be used in reverse also. Type 3RV23 is identical to the standard series device but thermal overload trip is out of function. Type 3RV21 is identical to the standard series device but with no motor overload function. The internal overload tripping system does not trip the controller, however it trips the attached trip module for indication to remote panels. Type 3RV24 is identical to the standard series device but instantaneous tripping is adjusted to 19 x Ie. These devices may be provided with certified accessories of Type 3RV19, 3RV29, 8US1, including auxiliary switches, door coupling rotary mechanism, tripping units, bus bar assembly and short circuit indicators.. Any information and documentation involving UL Mark services are provided on behalf of (UL) or any authorized licensee of UL. For questions, please Page 2 of 11

Ratings: Setting Range 0.9-1.25 A (-0K) Voltage 115/120 V - - 200/208 V - - 230/240 V - - *460/480 V - 3/4 *575/600 V - 3/4 Setting Range 1.1-1.6 A (-1A) Voltage 115/120 V - - 200/208 V - - *230/240 V 1/10 1/2 *460/480 V - 1 *575/600 V - 1 Setting Range 1.4-2 A (-1B) Voltage 115/120 V - - 200/208 V - - *230/240 V 1/6 1/2 *460/480 V - 1 575/600 V - 1 1/2 Setting Range 1.8-2.5 A (-1C) Voltage *115/120 V 1/10-200/208 V 1/6 1/2 *230/240 V 1/4 3/4 460/480 V - 1 1/2 *575/600 V - 2 Any information and documentation involving UL Mark services are provided on behalf of (UL) or any authorized licensee of UL. For questions, please Page 3 of 11

Setting Range 2.2-3.2 A (-1D) Voltage 115/120 V 1/8-200/208 V 1/4 3/4 230/240 V 1/3 1 460/480 V - 2 575/600 V - 3 Setting Range 2.8-4 A (-1E) Voltage 115/120 V 1/6 1/2 200/208 V 1/3 1 230/240 V 1/2 1 460/480 V - 3 575/600 V - 3 Setting Range 3.5-5 A (-1F) Voltage 115/120 V 1/4 1/2 200/208 V 1/2 1 1/2 230/240 V 1/2 1 1/2 460/480 V - 3 575/600 V - 5 Setting Range 4.5-6.3 A (-1G) Voltage 115/120 V 1/4 3/4 200/208 V 1/2 2 *230/240 V 3/4 2 460/480 V - 5 575/600 V - 5 Any information and documentation involving UL Mark services are provided on behalf of (UL) or any authorized licensee of UL. For questions, please Page 4 of 11

Setting Range 5.5-8 A (-1H) Voltage 115/120 V 1/3 1 200/208 V 1 2 230/240 V 1 3 460/480 V - 5 575/600 V - 7 1/2 Setting Range 7-10 A (-1J) Voltage 115/120 V ½ 1 1/2 200/208 V 1 1/2 3 230/240 V 1 ½ 3 460/480 V - 7 1/2 575/600 V - 10 Setting Range 9-12.5 A (-1K) Voltage *115/120 V 3/4 1 ½ *200/208 V 2 3 *230/240 V 2 5 460/480 V - 7 ½ 575/600 V - 10 Setting Range 10-16 A (-4A) for 3RV2.1 only Voltage 115/120 V 1 2 200/208 V 2 3 230/240 V 2 5 460/480 V - 10 *575/600 V - - Any information and documentation involving UL Mark services are provided on behalf of (UL) or any authorized licensee of UL. For questions, please Page 5 of 11

Setting Range 10-16 A (-4A) for 3RV2.2 only Voltage 115/120 V 1 2 200/208 V 2 5 230/240 V 3 5 460/480 V - 10 575/600 V - 10 1) Setting Range 13-20 A (-4B) Voltage 115/120 V 1 ½ 3 *200/208 V 3 7 1/2 *230/240 V 3 7 1/2 *460/480 V - 15 575/600 V - 15 1) Setting Range 16-22 A (-4C) Setting Range 18-25 A (-4D) Voltage 115/120 V 1 ½ 3 *200/208 V 3 7 1/2 230/240 V 3 7 ½ 460/480 V - 15 575/600 V - 20 1) Voltage 115/120 V 2 3 200 V 3 7 1/2 208 V 3 7 1/2 230/240 V 3 7 1/2 460/480 V - 20 575/600 V - 20 1) 1): Only 3RV2.23 are rated for 600V. Any information and documentation involving UL Mark services are provided on behalf of (UL) or any authorized licensee of UL. For questions, please Page 6 of 11

Setting Range 23-28 A (-4N) Voltage 115/120 V 2 3 200/208 V 3 7 1/2 230/240 V 5 10 460/480 V - 20 575/600 V - - Setting Range 27-32 A (-4E) Voltage 115/120 V 2 5 *200 V 3 10 208 V 5 10 230/240 V 5 10 460/480 V - 20 575/600 V - - Setting Range 30-36 A (-4P) Voltage 115/120 V 3 5 200/208 V 5 10 230/240 V 5 10 460/480 V - 25 575/600 V - - Setting Range 34-40 A (-4F) Voltage 115/120 V 3 5 200/208 V 5 10 230/240 V 7 ½ 10 460/480 V - 30 575/600 V - - Any information and documentation involving UL Mark services are provided on behalf of (UL) or any authorized licensee of UL. For questions, please Page 7 of 11

3RV2.11 and 3RV2.21 only: General Purpose: 600 V AC, (Up to 12.5 A, until -1K-Version, see Nomenclature Breakdown for Individual Ampere Rating) 3RV2.23 only: General Purpose: 600 V AC, (12.5 A Up to 25 A, from -1K until -4D-Version, see Nomenclature Breakdown for Individual Ampere Rating) General Purpose: 480 V AC, (See Nomenclature Breakdown for Individual Ampere Rating) FLA Ratings: (See Nomenclature Breakdown for individual FLA ratings) 36A and 40A-Version only: Surrounding air temperature 40 C. Pilot Duty rating for 3RV21 trip module outputs 1 NO + 1 NC: C600, R300 opposite polarity Short-Circuit Ratings: 3RV2.11 and 3RV2.21 only: 240 V, 3 phase, 65,000 rms sym. Amperes for ratings up to 40 A 480 V, 3 phase, 65,000 rms sym. amperes for ratings 0.11 up to 25 A 480 V, 3 phase, 50,000 rms sym. Amperes for ratings 28 up to 32 A 480 V, 3 phase, 12,000 rms sym. Amperes for ratings 36 up to 40 A 600 V, 3 phase, 30,000 rms sym. Amperes for ratings 0.11 up to 12.5 A Maximum Short-circuit rating in Group Installations: 240 V, 3 phase, 65,000 rms sym. Amperes for ratings up to 40 A 480 V, 3 phase, 65,000 rms sym. amperes for ratings 0.11 up to 25 A 480 V, 3 phase, 50,000 rms sym. Amperes for ratings 28 up to 32 A 480 V, 3 phase, 12,000 rms sym. Amperes for ratings 36 up to 40 A 600 V, 3 phase, 30,000 rms sym. Amperes for ratings 0.11 up to 12.5 A These devices were tested for group installation use at the above levels without any upstream branch circuit device. Branch Circuit Protective device: The appropriate BCPD need to be determined in accordance with the National Electrical Code, Article 430-53 and the application. Any information and documentation involving UL Mark services are provided on behalf of (UL) or any authorized licensee of UL. For questions, please Page 8 of 11

The following devices are suitable for tap conductor protection in group applications (3RV20 only, except 3RV2023) and/or over current protection for control transformers in group applications with the following ratings: Setting range Voltage Short Circuit 0.11 25 A (Version -0A up to -4D) 240 V 65 ka 28 A 32 A (Version -4N and -4E) 240 V 50 ka 0.11 25 A (Version -0A up to -4D) 480Y/277 V 65 ka 28 A 32 A (Version -4N and -4E) 480Y/277 V 50 ka 0.11 12.5 A (Version -0A up to -1K 600Y/347 V 30 ka These devices are suitable to provide over current protection for control transformers. These devices are suitable as motor disconnect. 3RV2.23 only: Maximum Short-circuit rating in Group Installations: 600 V, 3 phase, 5,000 rms sym. Amperes for ratings 12.5 up to 25 A These devices were tested for group installation use at the above levels without any upstream branch circuit device. Branch Circuit Protective device: The appropriate BCPD need to be determined in accordance with the National Electrical Code, Article 430-53 and the application. 600 V, 3 phase, 30,000 rms sym. Amperes for ratings 12.5 up to 25 A when protected by max. 200A Class J Fuse These devices are suitable as motor disconnect. Any information and documentation involving UL Mark services are provided on behalf of (UL) or any authorized licensee of UL. For questions, please Page 9 of 11

NOMENCLATURE BREAKDOWN 3RV20 21-4A A 1 8 I II III IV V VI I. Basic Type 3RV20 Manual Motor Controller for motor protection 3RV21 - Manual Motor Controller for motor protection with overload function (Only up to 32A) 3RV23 - Manual Motor Controller for starter combination 3RV24 - Manual Motor Controller for transformer protection (Only up to 25A) II. Size of terminal for main circuit 11 Up to 16 A (rated for 600V only up to 12.5A) 21 Up to 40 A (rated for 600V only up to 12.5A) 23 - Only for setting ranges 12.5 to 25 A III. Setting Ranges Suffix From to (A) max. Fuse or CB for 3RV2.11, 3RV2.21* max. Fuse Class J for 3RV2.23* -0A 0.11 0.16 15 A - -0B 0.14 0.2 15 A - -0C 0.18 0.25 15 A - -0D 0.22 0.32 15 A - -0E 0.28 0.4 15 A - -0F 0.35 0.5 15 A - -0G 0.45 0.63 15 A - -0H 0.55 0.8 15 A - -0J 0.7 1 15 A - -0K 0.9 1.25 15 A - -1A 1.1 1.6 15 A - -1B 1.4 2 15 A - -1C 1.8 2.5 15 A - -1D 2.2 3.2 15 A - -1E 2.8 4 15 A - -1F 3.5 5 20 A - -1G 4.5 6.3 25 A - -1H 5.5 8 30 A - -1J 7 10 40 A - -1K 9 12.5 50 A 50 A -4A 10 16 60 A 60 A Any information and documentation involving UL Mark services are provided on behalf of (UL) or any authorized licensee of UL. For questions, please Page 10 of 11

-4B 13 20 80 A 80 A -4C 16 22 80 A 80 A -4D 18 25 100 A 100 A -4E 27 32 125 A - -4F 34 40 150 A - -4N 23 28 110 A - -4P 30 36 1 2 5 A - When used as manual motor starter but not in group installation applications IV. Tripping Class A Setting ranges with instantaneous tripping and overload tripping Class 10. C With instantaneous tripping and without overload tripping. V. Type of Terminals 1 Screw Terminal 2 Spring terminals (Only up to 32A) 4 Ring lug terminals (Only up to 32A) VI. Auxiliary Switches (Combinations with certified accessories Type 3RV29...) 0 without 1 1NO + 1NC, side mounted 2 2NO, side mounted 3 2NC, side mounted 4 1NO/NC Changeover, top mounted 5 1NO + 1NC, top mounted 3RV2928-4AA00 - Terminal cover for ring-lug-terminals Any information and documentation involving UL Mark services are provided on behalf of (UL) or any authorized licensee of UL. For questions, please Page 11 of 11