MultiTherm Shaker. Operations Manual Item: H5000-H and H5000-HC

Similar documents
Incubator Shaker with Cooling

Digital Overhead Stirrer

Operation Manual. Concorde 600 Power Supply. *This instrument is intended for laboratory use only.

EPS Power Supply

HD Mini IR Waterproof Fixed Network Camera. Quick Start Guide. Version 1.2.0

INSTRUCTION MANUAL. Instruction Manual. Analog Multi-Tube Vortexer Digital Multi-Tube Vortexer

INSEBO2IRF 2.1MP 1080P IP Eyeball Camera with IR

Thermo Scientific Digital Drybath

Operating Manual. Operating Manual. MicroMixer. confido-s202h. Incubator-MICRO mixer.

Full HD IP Vandal Dome Camera

FT-20 Fire Training Fog Machine User Manual English

User Manual. Trinocular Stereo Microscope

Dahua HD IR Vari-Focal Fixed Network Camera. Quick Start Guide

NIR Moisture Analyzer KB-30

JanusRAID SA-6692J Hardware User Manual

User Manual. Binocular Stereo Microscope. MicroscopeNet.com

E-37-V Dome Network Camera. Quick Start Guide

Z-380 Fazer Machine User Manual English

Quick Start Guide. 2MP 4X PTZ IP Camera O2P4X

Available in 2.0MP, 4.0MP, 6.0MP and 8.0MP, with 2.8mm and 3.6mm lenses.

PRODUCT MANUAL SMOKE-1500 ENGLISH. Version: 1.0

HD Analog Camera User s Manual

Dahua HD Fixed-focal Pinhole Network Camera

Instruction Manual Standard Multi-Position Stirrers Advanced Multi-Position Stirrers

Marshall Lynx LCD Universal Monitors

Thermal Shake Touch heat. cool. mix. repeat.

PS8 - II. Professional Power Sequencer. User s Manual

Available in 2.0MP, 4.0MP and 8.0MP variants

Large Police Light 100W ORDERCODE 80361

BILL COUNTER OPERATION MANUAL PRODUCT #700012

Operational Manual Spectrophotometer Model: SP-830 PLUS Metertech Inc.

FT-20 Fire Training Fog Machine User Manual English

Octostrip ORDERCODE 42220

DOT MATRIX PRINTER SP6000 SERIES

Smartphone Photo Printer Item No

W-715 Fog Jet USER MANUAL English 2013 Antari Lighting and Effects Ltd.

Z-350 FAZER USER MANUAL

PA Series. Available in 6.0MP and 8.0MP

Party Dimmer IEC ORDERCODE 50324

CNK600 Cable-Nook Interconnect Box

PHOS mini OPERATING INSTRUCTIONS

FAZE 800 FT PRO USER MANUAL. Version: 1.2. ROBE Lighting s.r.o. Czech Republic

MyGenie TM 32 Thermal Block

Analog Multi-Tube Vortexer Digital Multi-Tube Vortexer

Model 2380 Rack-Mount Kit

Model 2380 Rack-Mount Kit

1 Channel Strobe Controller ORDERCODE 40226

HD IR Vandal Proof Network Dome Camera. Quick Start Guide. Version 1.0.0

MyGenie TM 96/384 Thermal Block

DNG-200 LOW FOG GENERATOR USER MANUAL DNG-200 低煙機使用說明書

A Series HD Wi-Fi Network Camera. Quick Start Guide. Version 1.0.1

Models 2601B, 2602B, and 2604B System SourceMeter Instruments Quick Start Guide

Haze 800 DMX. User Guide. English

The following symbols are used to show dangerous operation or handling. Make sure you understand them before reading the guide.

1. INTRODUCTION 2. INTENDED USE 3. FEATURES

Stage Fog Machine User Manual

CA846 THERMO-HYGROMETER ENGLISH. User Manual. 99 Washington Street Melrose, MA Phone Toll Free

Model P4017 Single Channel USB Oscilloscope. Quick Start Guide

TOP - 1. Instruction Manual. Version 1.0 Produced in Jan. 2004

Operating and Installation Manual. EASYLAB Expansion modules Type EM-TRF for 230 V AC mains voltage

OPERATING INSTRUCTIONS PA AMPLIFIER P-1812

Smartphone Photo Printer

Thermo Scientific ALPS 50V User s Guide

IGB Series. Operation Manual. Platform Scale. Kg/Lb Specification IMPORTANT

Instruction Manual. Rocking Platform Shaker. 3-D Rotator Waver

Please read this guide before using the printer

6 x 6 Peltier-Thermostatted Multicell Holder Series II Accessory

Vacuum Tubes Power Supply Unit. for WA7 and WA7d Fireflies. Owner s Manual. Please review this manual before operating your WOO AUDIO product.

Model 2460-KIT. Screw Terminal Connector Kit. Description / September 2014 *P * 1

Toll Free: Tel: Fax:

UWE-1707 SERIES CONTENTS OPERATION MANUAL ELECTRONIC WEIGHING INDICATOR 1. SPECIFICATIONS 2. INSTALLATION

ALO Duo Roll DMX LED barrel scanner with dual light source

User's Guide. Model W 3-in-1 Switching DC Power Supply

V1.0. Showven Technologies Co.,Ltd.

LCU-2S Liquid Supply System User Manual English

PNP415/417 POP 'N PLUG WITH CUSTOM TABLETOP SURFACE USER'S GUIDE

CM/CS SERIES. Compact 100V amplifiers. Item ref: UK, UK, UK User Manual. CM/CS Series User Manual

Light Brick ORDERCODE 50370

Linear Shaker & Orbital Shaker

User Manual VIDEO DOOR PHONE

User s Manual Prudent Way Universal Notebook & LCD AC Power Adapter PWI-AC90LE, PWI-AC120LE

HD IR Vari-focal Dome Network Camera. Quick Start Guide. Version 1.1.0

DS-1H05 Ethernet-over-Coax Extender. User Manual

ITA100 MKII 100mW green DMX laser

Platform Rocker PMR-100

User Manual DUO BEAM/RG

Safety. Features 1 ID: Make all the connections before you plug in the main power. DMX512 Controllable and RDM Configurable

Serial No. OWNER S MANUAL. Installation & Operation

dedicated KVM switch and rackmount screen technology User Manual CV-1201D DVI-D KVM Designed and manufactured by Austin Hughes

Installation Manual INTELLIGENT SERVER. Model name: BMS-LSV6UL

Instruction Manual. Professional 1000WS Incubating. Rocking Shaker. Waving Shaker

SW-250 Wireless Control High Output Snow Machine User Manual

If you have questions about your KCD-2000 and its operation, please contact technical support at

Sivy SA-4327S Hardware User Manual

ATOM. Instruction Manual. Head. from software version: 8.

E8431 First Edition Model: T00CP

Model #28599 Wireless Bluetooth Surround Bar & Subwoofer 285W

MX-T6-PRO/S Tube Rollers

HD Mini IR Waterproof Bullet Network Camera. Quick Start Guide. Version 1.0.0

INFORMATION AMPLIFIER TA-102 OPERATING INSTRUCTIONS TABLE OF CONTENTS

Transcription:

MultiTherm Shaker Operations Manual Item: H5000-H and H5000-HC

Foreword Thank you for purchasing a MultiTherm Shaker. This operations manual contains instructions for the care of this Instrument. In order to use the instrument properly, please read this manual carefully before operation. Please keep it available for future use. Prior to the initial operation: Please check the Instrument and the accessories against the packing list when you first open the shipping carton. If you find there is damage, a discrepancy, or missing items, please contact the supplier immediately. - 1 -

Safety Warnings and Guidelines 1. Important operation information: Please read this manual carefully prior to any attempt to operate the Instrument. Read the manual prior to power up of the instrument. Read the guidelines and directions below and be familiar with all safety warnings and guidelines. 2. Security: The operation, maintenance and repair of the Instrument must comply with the basic guidelines and warnings stated below. Failure to comply may jeopardize the instrument life, warranty coverage and user safety. Use this product indoors. Do not operate in a damp or wet environment. Do not attempt to disassemble or repair the Instrument by yourself. Disassembly will void the warranty. If there is a malfunction contact your supplier for repair service. The three pin plug supplied with the instrument is a safety device that should be matched with a suitable grounded outlet. Do not attempt to defeat the three pin plug or its grounded function. During normal operation, the temperature of metal block will become very hot. Do not touch the block during or within 30 minutes of operation. Close all test tube lids before inserting into the block. Do not allow liquids to spill into the block or any part of the instrument. - 2 -

Before connectivity to a power source, check that the voltage listed on the serial number label (on the bottom or back side of the unit) to ensure that it matches the voltage available in your area. Be sure to install the Instrument in a cool, dry location away from any direct sunlight or strong light sources. Additionally the instrument should be kept away from corrosive gas, magnetic fields and dusty environments. Keep the instrument and the air vents at least 4 inches from walls, other instruments or any obstructions. The Main power switch is on the rear of the device, push I to power on the instrument, and push O to power off. Shut the power off when you finish your work. Unplug the machine if it will not be operated for a long time period and cover it with a cloth or plastic paper for protection from dust particles Immediately unplug the instrument from the outlet and contact the vendor in the event of: Fire or smoke. Liquid has gotten into the Instrument; Abnormal operation: such as abnormal sound or smell. Instrument has been dropped or outer case is damaged. The function has visibly changed. 3. Maintenance of the Instrument The block wells should be cleaned by a cloth dampened with alcohol to ensure good heat transmission between the block and the test tube. If there are marks, dirt or stains on the instrument exterior, clean them with a cloth dampened with water or a mild detergent solution. Always shut the power off when cleaning the Instrument. When cleaning the block wells, do not apply the cleaning liquid directly to the block, use a dampened cloth. Do not use strong or corrosive cleaning agents. - 3 -

Contents Chapter 1: Introduction 5 Chapter 2: Specifications 5 1. Normal operating conditions 5 2. Technical data 6 Chapter 3: Preparations 8 1. Physical Description 8 2. Keyboard and Display panel 9 3. Key Functions 10 Chapter 4: Operation Guide 11 1. Single Temperature, Speed and Time setting 11 2. Sequence Link Setting 12 3. Disabling the Temperature Speed or Time 12 4. Pulse 13 5. Temperature Calibration 13 6. Changing the Block 16 Chapter 5: Failure analysis and troubleshooting 17-4 -

Chapter 1: Introduction The MultiTherm shaker is an ideal instrument for intensive mixing of samples under temperature regulated conditions. Mixing and temperature control modes can be used both simultaneously and independently i.e, the device can work as shaker and/or as an incubator. The base instrument can be used with a variety of different blocks. The instrument is applicable for DNA analysis, extraction of lipids and other cell components, DNA library creation, PCR amplification, pre-denaturation in electrophoresis, serum solidification etc. Features of this product as follows: 1. Because it can be used with various optional mixing blocks, the instrument can adapt to different tubes and plates to accommodate many experimental needs. Customized blocks are available to suit your specific demands. 2. LCD display 3. Simultaneous display of set and actual time, temperature and speed 4. Over-heat protection system ensures safety & reliability 5. Temperature can be calibrated to meet the user's needs 6. End-of-run signal alerts the user of cycle completion Chapter 2: Specifications 1. Normal operating conditions Ambient temperature: 5 C ~30 C / Relative humidity: 70% Note: Do not attempt to operate the instrument at temperatures or humidity levels outside of this range. 5

2. Technical data, H5000-H Parameter Mixing rate* Orbit Model H5000-H 200~1500 rpm 2mm Temperature setting range 5 C to 100 C Temperature control range* Ambient +5 C to 100 C Timing range Accuracy of the temperature Heating time 1min to 99h59min 0.5 C 15min (from 20 C to 100 C) Cooling time N/A A-BLOCK: 96 well Plate or 96 x 0.2ml; B-BLOCK: 0.5ml x 54 C-BLOCK: 1.5ml x 35 Block Configuration D-BLOCK: 2.0ml x 35 E-BLOCK: 15ml x 12 F-BLOCK: 12mm x 24 G-BLOCK: 50ml x 6 H-BLOCK: 0.5ml x 20 & 0.5ml x15 Power Supply AC100-120~ 2.5A 50-60Hz AC200-240~ 1.5A 50-60Hz Fuse 250V 4.0A Ф5 20mm 250V 3.0A Ф5 20mm Dimension (mm) 300(D) 2 12(W) 210(H) Net weight (kg) 8.5 *Specification is valid when used with standard blocks only. Larger blocks (Blocks E, F and G) have different speed and temperature specifications. 6

Technical data, H5000-HC Parameter Mixing rate* Orbit Model H5000-HC 200~1500 rpm 2mm Temperature setting range 0 to 100 C 0 to 100 at Room temp. 20 C Temperature control range* 4 to 100 at Room temp. 25 C 10 to 100 at Room temp. 30 C Timing range Accuracy of the temperature Heating time 1min ~ 99h59min 0.5 C 15min (from 20 C to 100 C) Cooling time 30min from room temp. to -20 C below room temp. A-BLOCK: 96 well Plate or 96 x 0.2ml; B-BLOCK: 0.5ml x 54 C-BLOCK: 1.5ml x 35 Block Configuration D-BLOCK: 2.0ml x 35 E-BLOCK: 15ml x 12 F-BLOCK: 12mm x 24 G-BLOCK: 50ml x 6 H-BLOCK: 0.5ml x 20 & 0.5ml x15 Power Supply AC100-120~ 2.5A 50-60Hz AC200-240~ 1.5A 50-60Hz Fuse 250V 4.0A Ф5 20mm 250V 3.0A Ф5 20mm Dimension (mm) 300(D) 2 12(W) 210(H) Net weight (kg) 8.5 *Specification is valid when used with standard blocks only. Larger blocks (Blocks E, F and G) have different speed and temperature specifications. 7

Chapter 3: Preparations This chapter provides a physical description, location of controls, function of individual keys, as well as some preparations before the initial power-on. You should be familiar with this chapter before the Thermo Shaker is first operated. 1. Physical Description Standard Block Keyboard Power Switch Power connector Fuse 8

2. Keyboard and Display panel Display Panel: Current program Current temperature Current speed Remaining time P1 100.0 1200 10:30 P1 100.0 1200 15:00 Selected program Selected temperature Selected speed Selected time 9

3. Key Functions Prog. Program Selection Keys: Use the up and down keys to choose the desired program (P1, P2, P3, P4 or P5). Temp. Temperature Selection Keys: Press or to select the desired temperature in increments of 1 C. (To quickly scroll to the desired temperature, press and hold the or keys.) Speed Speed Selection Keys: Press or to select the desired mixing speed in increments of 10rpm. (To quickly scroll to the desired mixing speed, press and hold the or keys.) Time Time Selection Keys: Press or to select the desired run time. (To quickly scroll to the desired time, press and hold the or keys.) Seq. Link Sequence Link Key. Press the Seq. Link key to run consecutive programs. Choose from P1 to P2, P1 to P3, P1 to P4, or P1 to P5 to run up to five consecutive programs. (The Sequence link function is only available on the H5000-HC.) Pulse Start/Stop The device mixes at the speed shown on the display for as long as the Pulse key is held down. The time is counted in seconds until 999 Seconds has expired. Start/Stop Key. press this key to start or stop the program. Press briefly to start. Press and hold to stop. 10

Chapter 4: Operation Guide 1. Single temperature, speed and time setting a) Following power up, the unit beeps once and the LCD will display System Testing. After approx. 5 seconds, the current and selected settings appear on the display and the instrument is ready for use. System Testing... b) The current block temperature is displayed on the LCD, for example, 30.0 along with the current mixing speed, 0 rpm and the current time, 00:00. The set or selected temperature shows 37.0, which is the initial preset temperature. The initial preset mixing speed and time are also displayed at 1000rpm and 10:00 respectively. c) Five programs are available for storage. By pressing the or Prog. keys,choose the desired program, P1, P2, P3, P4 or P5. By pressing the or Temp. keys,the value of the selected temperature is adjusted in increments of 0.1 C on the display window. By pressing the or Speed keys,the value of the selected mixing speed is adjusted in increments of 10 rpm. Prog P1 30.0 0 00:00 P1 37.0 1000 10:00 Temp P1 30.0 0 00:00 P1 40.0 1000 10:00 Speed P1 30.0 0 00:00 P1 40.0 1200 10:00 By pressing the or time keys,the value of the selected run time is adjusted in increments of 1 min. Time P1 30.0 0 00:00 P1 40.0 1200 2:00 11

NOTE: Press and hold the or adjustment keys to quickly scroll through the available temperature, speed and time range Press the Star/Stop Key to begin the cycle 2. Sequence Link Program Setting (Available on H5000-HC only) a) By Pressing the Seq. Link Key, the user can connect up to five programs to run consecutively (P1-P2, P1-P2-P3, P1-P2-P3-P4, P1-P2-P3-P4-P5). b) Once the Seq. Link button is pressed, the display shows the starting program P1 and the default PROG to validate Star:P1 End:P2 ending program, P2. To adjust the ending program, press the or Prog. Keys. Once the ending program has been selected, press the Seq. Link key to finalize. P1 30.0 0 00:00 P14 50.0 1400 3:00 c) To begin the first program, press the start/stop key. The first program will run through completion. Following completion, the subsequent cycle will begin automatically. NOTE: A program can always be stopped (cancelled) by pressing and holding the start/stop key. 3. Disabling the temperature, speed or time functions. a) To deactivate the temperature control, press and hold the Temp. key until the set temp. shows OFF. The temperature control is now deactivated and the instrument can be used solely as a shaker/mixer. 12

b) To deactivate the shaker speed, press and hold the Speed key until the set speed shows OFF. The shaker is now deactivated and the instrument can be used solely for temperature control. c) To deactivate the timer, press and hold the Time key until the set time shows OFF. The timer is now deactivated and the instrument will run continuously until the user presses and holds the start/stop key. NOTE: When running consecutive programs in the Seq. Link mode, the time should not be set to OFF in any program. 4. Pulse By pressing and holding the Pulse key, the instrument mixes at the selected speed for as long as the Pulse key is held down. The time is Pulse is running 600rpm 023S counted in seconds until 999 seconds has expired. 5. Temperature calibration The temperature of the Instrument has been factory adjusted and calibrated prior to being shipped. But if there is deviation between the actual temperature and the displayed temperature, the user can self-calibrate the instrument in order to correct the error. Note: The temperature accuracy will be within ±0.5 C. Calibration Procedure: a) Verify that the ambient temperature is less than 25 C and power up the instrument. Once powered on, verify that the current temperature in display is below 25 C. If the temperature is above than 25 C, please wait for the unit to cool down to 25 C or less. b) Inject olefin oil into one of the cone-shaped wells, and insert a thermometer into this well. (Make sure the accuracy of the thermometer is to be within 0.1 C and that it is completely immersed into well). Heat insulation material is needed on the block to insulate it from the ambient temperature. See Fig a.: 13

Thermometer Insulating sheet Standard Mineral Oil Well-bottom Fig. A Notes: Please read the actual value after allowing 20 minutes constant temperature equilibration time. To enter the temperature calibration mode, press the and Prog. Keys simultaneously. The instrument begins to cool to the low calibration point. - H5000-H Calibration points: 40 C, 100 C P:20.5 ADJ AdjTemp= 10.0 P:10.0 AdjTemp= ADJ 10.0 - H5000-HC Calibration points: 10 C, 40 C, 100 C c) After 20 mintues,read the temperature of the Thermometer (for ex. 9.8 C). Using the or Temp. keys, adjust the temperature of the display to match that of the thermometer and press the start/stop key to confirm. P:10.0 ADJ AdjTemp= 9.8 Press stop/start 14

d) Repeat the above step for the remaining temperature calibation points. P:40.1 ADJ AdjTemp= 40.0 Following the adjustment to the final calibration point, the temperature calibration of the instrument has now been completed and the displayed temperature will accurately represent the temperature of the heating block. P:100.0 Adj AdjTemp= 98.0 NOTE: During the temperature calibration, press the and Prog. keys simultaneously to cancel the calibration. The system will default back to the former calibration. 15

6.Changing the block a) Open the transparent lid and use the supplied hex wrench (3mm) to remove the four screws that hold the block to the heating board. b) Close the lid and lift the block up and away from the base unit. c) Place the desired block softly on the heating platform of the base unit and carefully align the four screw holes. d) Install and tighten the four screws. Do not over tighten. Screw 16

Chapter 5: Failure analysis and troubleshooting Failure analysis and processing procedures No. Symptom Possible Causes Action No power Check the power 1 No display when powered up. Fuse failure Broken switch Exchange fuse(250v 3.0A 5X20mm) Replace the switch Others Call for service 2 The actual and displayed temperatures are significantly different. Temperature sensor failure Call for service 3 OPEN in the temperature display with a short beep Temperature sensor failure or the environmental temperature is below zero Call for service 4 SHORT in the temperature display with a shirt beep 5 No heating or cooling 6 No reaction when a key is pressed Temperature sensor failure or the environmental temperature is below zero Broken sensor or Broken TE module Failed film switch Call for service Call for service Call for service

Notes PH: 908-769-5555 EM: info@benchmarkscientific.com