Dell PowerEdge VRTX Storage Subsystem Compatibility Matrix

Similar documents
Dell Chassis Management Controller Version 3.0 for PowerEdge VRTX. Release Notes

Dell Storage PowerTools Server Hardware Manager 2.1 Support Matrix

Dell EMC PowerEdge Systems SUSE Linux Enterprise Server 15. Installation Instructions and Important Information

Dell Chassis Management Controller Version 3.10 for PowerEdge VRTX. Release Notes

Dell Chassis Management Controller Version 3.20 for PowerEdge VRTX. Release Notes

OpenManage Integration for VMware vcenter Version 4.2. Compatibility Matrix

Dell EMC OpenManage Enterprise Tech Release. Support Matrix

OpenManage Management Pack for vrealize Operations Manager version 1.0 User s Guide

Dell Shared PowerEdge RAID Controller 8 Cards For Dell PowerEdge VRTX Systems

SanDisk DAS Cache Compatibility Matrix

Dell EMC PowerEdge Systems Red Hat Enterprise Linux 7. Installation Instructions and Important Information

OpenManage Management Pack for vrealize Operations Manager version 1.1. User s Guide

Dell EMC OpenManage Enterprise Version 3.0. Support Matrix

Dell EMC SupportAssist Enterprise Version 1.0 Support Matrix

Dell OpenManage Plug-in Version 1.0 For Nagios XI Installation Guide

Dell EMC Storage Enclosure Support Matrix

OpenManage Integration for VMware vcenter Version 4.2.0

OpenManage Integration for VMware vcenter Version 4.1. Compatibility Matrix

Dell EMC Repository Manager Version 3.0. Troubleshooting Guide

Dell EMC PowerVault MD3060e Storage Enclosure. Deployment Guide

Dell DL1300 Appliance Interoperability Guide

Dell PowerEdge RAID Controller S140 - PERC S140. User s Guide

Microsoft Windows Server 2016 for Dell EMC PowerEdge Systems. Important Information Guide

Dell PowerEdge FD332. Owner's Manual. Regulatory Model: E02B Regulatory Type: E02B003

OpenManage Integration for VMware vcenter Version Compatibility Matrix

Dell EMC Server Deployment Pack Version 4.0 for Microsoft System Center Configuration Manager. Installation Guide

Lifecycle Controller Operating System Driver Pack Version Reference Guide

Dell Host Bus Adaptor User s Guide

Lifecycle Controller 2 Release 1.0 Version Readme

Dell EMC OpenManage Deployment Toolkit Version 6.1. Installation Guide

Dell EMC Systems Management Tools And Documentation Installation Guide. Version 9.1

VMware vsphere ESXi 6.x on Dell EMC PowerEdge Systems. Image Customization Information

Dell EMC OpenManage Deployment Toolkit Version Installation Guide

Simplifying Blade Server Update with Dell Repository Manager

OpenManage Integration for VMware vcenter Version 4.0 Release Notes

Active System Manager Version 8.0 Compatibility Matrix Guide

Dell OpenManage Connection Version 3.0 for IBM Tivoli Netcool/OMNIbus. Installation Guide

Dell EMC OpenManage Software Support Matrix Version 9.0.1

Dell SupportAssist Version 2.1 for Dell OpenManage Essentials Support Matrix

Dell Smart Plug-in Version 4.1 For HP Operations Manager 9.0 For Microsoft Windows User's Guide

Dell EMC Server Management Pack Suite Version 7.0 for Microsoft System Center Operations Manager. User's Guide

Lifecycle Controller Version User's Guide

Dell EMC Host Bus Adapter User's Guide

Dell Storage Designed for Scality RING Support Matrix

Dell EMC NX3340 and NX3240 Network Attached Storage System using Windows Storage Server Troubleshooting Guide

Dell Command Update. Version 3.0 Release Notes

Dell EMC BOSS-S1 (Boot Optimized Server Storage) User's Guide

Microsoft Windows Server 2019 for Dell EMC PowerEdge Servers. Release Notes

Active System Manager Release 8.2 Compatibility Matrix

Microsoft Windows Server 2012 R2 For Dell PowerEdge Systems Important Information Guide

OpenManage Management Pack for vrealize Operations Manager Version 1.1. Installation Guide

Dell EMC SupportAssist Enterprise Version 1.0 User's Guide

VMware vsphere ESXi 6.x on Dell EMC PowerEdge Systems. Image Customization Information

Dell PowerVault MD Storage Array Management Pack Suite Version 6.1 for Microsoft System Center Operations Manager User's Guide

Migration from Dell Lifecycle Controller Integration Version 3.3 for Microsoft System Center Configuration Manager to OpenManage Integration Version

Dell PowerEdge FC640. Technical Specifications. Regulatory Model: E02B Series Regulatory Type: E02B005

Dell Chassis Management Controller for Dell EMC PowerEdge FX2 Version 2.0. Release Notes

Dell PowerEdge RAID Controller (PERC) S130 User s Guide

Dell EMC Server Management Pack Suite Version 7.0 for Microsoft System Center Operations Manager. Installation Guide

Dell Openmanage Server Administrator Storage Management User Guide 6.5

Dell OpenManage Connection Version 3.0 for IBM Tivoli Netcool/OMNIbus Installation Guide

Dell OpenManage Connection Version 3.0 for IBM Tivoli Network Manager (ITNM) IP Edition User's Guide

Dell EMC OpenManage Mobile. Version 3.0 User s Guide (Android)

Dell Server Deployment Pack Version 3.1 for Microsoft System Center Configuration Manager Installation Guide

OpenManage Integration for VMware vcenter Version 4.3

Dell EMC OpenManage Plug-in Version 2.1 for Nagios Core. Release Notes

Dell Chassis Management Controller Version 6.0 for PowerEdge M1000e. Release Notes

Dell EMC BOSS-S1 (Boot Optimized Server Storage) User's Guide

Dell EMC OpenManage Software Support Matrix. Version 9.1

idrac8/7 with Lifecycle Controller Version Release Notes

Dell Chassis Management Controller for Dell EMC PowerEdge FX2 Version 2.1. Release Notes

Dell Lifecycle Controller Graphical User Interface Version For 13 th Generation Dell PowerEdge Servers User's Guide

Ubuntu Server LTS for Dell EMC PowerEdge Servers. Release Notes

Dell EMC Repository Manager Version 3.1. Troubleshooting Guide

Dell Lifecycle Controller Integration Version 3.0 For Microsoft System Center Configuration Manager User's Guide

Dell EMC ME4 Series JBOD 5U84 Enclosure

Dell EMC Storage Enclosure. PowerVault ME484 JBOD Support Matrix

Dell DR Series System Interoperability Guide for Releases and

Dell EMC PowerEdge Installation, Management and Diagnostics

Handling the Firmware Update Dependency by using Lifecycle Controller in the 14th generation Dell EMC PowerEdge servers

Dell Lifecycle Controller Integration Version 1.2 for Microsoft System Center 2012 Virtual Machine Manager User s Guide

Dell EMC PowerEdge FC640

Authors. Punita. Rajeswari Ayyaswamy. Lokesh Thutaram. Sanjeev Dambal. September, 2017

Dell Wyse Windows 10 IoT Enterprise for Latitude 5280 Mobile Thin Client. BIOS Upgrade Guide

Dell Lifecycle Controller GUI v User's Guide

Dell EMC OpenManage Enterprise-Modular Edition Version for PowerEdge MX7000 Chassis. Release Notes

21 TB Data Warehouse Fast Track for Microsoft SQL Server 2014 Using the PowerEdge R730xd Server Deployment Guide

Dell Lifecycle Controller GUI. v User's Guide

Dell Server Management Pack Suite Version 6.1 for Microsoft System Center Operations Manager User's Guide

Scalability and Performance of Dell EMC OpenManage Essentials (OME) Version 2.3

Dell Lifecycle Controller Operating System Driver Pack Version Reference Guide

Dell PowerVault Network Attached Storage (NAS) Systems Running Windows Storage Server 2012 Troubleshooting Guide

Dell OpenManage Connection Version 2.0 for IBM Tivoli Network Manager (ITNM) IP Edition User's Guide

Dell System E-Support Tool (DSET) Version 3.6 User's Guide

Dell Wyse Windows 10 IoT Enterprise for Latitude 3480 mobile thin client. BIOS upgrade guide

idrac8/7 with Lifecycle Controller Version Release Notes

Dell EMC OpenManage Mobile Version 2.0 User s Guide (ios)

Dell EMC OpenManage HPE OMi Operations Connector Version 1.0. User's Guide

Dell OpenManage Deployment Toolkit Version 5.3 Installation Guide

Dell Chassis Management Controller for Dell EMC PowerEdge FX2 Version Release Notes

Transcription:

Dell PowerEdge VRTX Storage Subsystem Compatibility Matrix Regulatory Model: E24S Regulatory Type: E24S001

Notes, cautions, and warnings NOTE: A NOTE indicates important information that helps you make better use of your product. CAUTION: A CAUTION indicates either potential damage to hardware or loss of data and tells you how to avoid the problem. WARNING: A WARNING indicates a potential for property damage, personal injury, or death. Copyright 2017 Dell Inc. or its subsidiaries. All rights reserved. Dell, EMC, and other trademarks are trademarks of Dell Inc. or its subsidiaries. Other trademarks may be trademarks of their respective owners. 2017-12 Rev. A07

Contents Minimum version requirement for baselines... 4 Current baseline... 4 Legacy baselines...4 Baseline threshold guidelines...6 Storage subsystem baseline types... 7 Baseline v7 Support for PowerEdge M640... 7 Baseline v6 current baseline Support for Self-Encrypting Drives and bug fixes... 8 Baseline v5 Shared Storage Expansion through Shared PERC 8 external controllers... 9 Baseline v4 Fault tolerant support for Linux operating systems and bug fixes...10 Updating firmware...12 Updating server modules...13 Updating PowerEdge VRTX enclosure components... 14 Documentation resources...15 Contents 3

Minimum version requirement for baselines The following are the baseline releases for the PowerEdge VRTX storage subsystem. Each baseline represents the release of a validated code stack. It also defines the minimum versions required for each component and the supported operating system for that baseline. Topics: Current baseline Legacy baselines Current baseline The current baseline is the most recently released and validated code stack. Dell recommends that you configure the VRTX system to comply with the current baseline. Only the current baseline has updates and bug fixes. This document might not reflect the latest updates and bug fixes. See Dell.com/support/home for the latest updates. Table 1. Current baseline Current baseline Baseline v7 Description Defines the minimum version baseline requirements for the PowerEdge VRTX storage subsystem to support PowerEdge M640. This baseline provides support for additional operating systems. Legacy baselines Legacy baselines include formerly released code stacks. Baselines are numbered in the order of release. For example, baseline v1 was the initial release for the VRTX system. Table 2. Legacy baseline Legacy baseline Baseline v6 Description Defines the minimum version baseline requirements for the PowerEdge VRTX storage subsystem to support FIPS-certified self-encrypting drives (SED). This baseline also provides support for additional operating systems. Improvements for both single and dual Shared PERC 8 configurations over the previous baselines. Baseline v5 Defines the minimum version baseline requirements for the PowerEdge VRTX storage subsystem that is associated with the introduction of Shared Storage Expansion via Shared PERC 8 external controllers and PowerVault MD1200 or MD1220 Storage Enclosures. This baseline provides: 4 Minimum version requirement for baselines

Legacy baseline Description Added support for Shared Storage Expansion via Shared PERC 8 external controllers and PowerVault MD1200 or MD1220 Storage Enclosures Support for additional operating systems Improvements for both single and dual Shared PERC 8 configurations over the previous baselines Support both single and dual Shared PERC 8 configurations for all supported operating systems Baseline v4 Defines the minimum version baseline requirements for the PowerEdge VRTX storage subsystem that is associated with the introduction of the Fault Tolerance support in Linux. This baseline provides: Fault tolerance on supported Linux operating systems Support for additional operating systems Improvements on both single and dual Shared PERC 8 configurations Baseline v3 Defines the minimum version baseline requirements for the VRTX storage subsystem that is associated with the introduction of the Write Back Cache support in a fault tolerant (dual controller) Shared PERC 8 configuration. This baseline: Provides Write Back caching in both single and fault tolerant configurations Provides improvements on both single and dual Shared PERC 8 configurations over the previous baselines Does not have backward compatibility with later baselines (Baseline v4) and will not be updated going forward Baseline v2 Defines the minimum version baseline requirements for the VRTX storage subsystem that is associated with the introduction of fault tolerant (dual controller) Shared PERC 8 configuration. This baseline: Provides support for both single and dual Shared PERC 8 configurations Provides Write Back caching in single controller configuration. Write Through caching in dual controller configurations Provides improvements on both single and dual Shared PERC 8 configurations over the previous baselines Does not have backward compatibility with later baselines (Baseline v3) and will not be updated going forward Baseline v1 Defines the minimum version baseline requirements for the VRTX storage subsystem that has only single Shared PERC 8. This baseline: Provides support for a single Shared PERC 8 configuration. Storage subsystem redundancy (dual Shared PERC 8) is not supported with this baseline Does not have backward compatibility with later baselines (Baselines v2) and will not be updated going forward Minimum version requirement for baselines 5

Baseline threshold guidelines 1 The storage subsystem should be compliant with only one baseline version. When any component in the storage subsystem is compliant with the minimum version requirements defined in one baseline, all components must also be brought into compliance with that same baseline. 2 Some operating systems are introduced with a particular baseline and are not supported with previous baselines. See the baseline definitions for operating system support. 3 Downgrading the storage subsystem from one baseline to an earlier baseline is not a supported operation. 4 It is recommended that the storage subsystem be updated to the current baseline. As the baselines define only the minimum version requirements, it is recommended that components be updated to the latest firmware and driver releases as provided in Dell.com/ support/home. 6 Baseline threshold guidelines

Storage subsystem baseline types Baseline v7 Support for PowerEdge M640 Table 3. Baseline v7 Support for PowerEdge M640 Shared PERC8 OS Driver or Chassis Components firmware Version CMC firmware 3.00 Chassis Infrastructure firmware 2.21 Shared PERC8 internal firmware 23.14.06.0013 Shared PERC8 external firmware 23.14.06.0013 Internal Expander backplane firmware 2.0 PowerVault MD1200/MD1220 Storage Enclosure firmware 1.06 Microsoft Windows Server 2016 6.805.03.00 Microsoft Windows Server 2012 R2 6.805.03.00 Microsoft Windows Server 2012 6.805.03.00 Microsoft Windows Server 2008 R2 6.805.03.00 VMWare ESXi 6.5 U1 6.806.90.00 VMWare ESXi 6.0 U3 6.805.56.00 VMWare ESXi 6.0 U2 6.805.56.00 VMWare ESXi 6.0 U1 6.805.56.00 VMWare ESXi 6.0 Patch 01 6.805.56.00 VMWare ESXi 5.5 U3 6.805.56.00 VMWare ESXi 5.5 U2 6.805.56.00 VMWare ESXi 5.5 U1 6.805.56.00 VMWare ESXi 5.5 6.805.56.00 VMWare ESXi 5.1 U3 6.805.56.00 VMWare ESXi 5.1 U2 6.805.56.00 VMWare ESXi 5.1 U1 6.805.56.00 SLES 12 SP3 6.904.09.00 SLES 12 SP2 6.904.09.00 SLES 12 SP1 6.904.09.00 SLES 12 6.904.09.00 SLES 11 SP4 6.904.09.00 Storage subsystem baseline types 7

Shared PERC8 OS Driver or Chassis Components firmware Version SLES 11 SP3 6.904.09.00 RHEL 7.4 7.770.50 RHEL 7.3 7.770.50 RHEL 7.2 7.770.50 RHEL 7.1 7.770.50 RHEL 6.9 6.904.09.00 RHEL 6.8 6.904.09.00 RHEL 6.7 6.904.09.00 RHEL 6.6 6.904.09.00 RHEL 6.5 6.904.09.00 Baseline v6 current baseline Support for Self- Encrypting Drives and bug fixes Table 4. Baseline v6 current baseline: Support for self-encrypting drives and bug fixes Shared PERC8 OS Driver or Chassis Components firmware Version CMC firmware 2.20 Chassis Infrastructure firmware 2.21 Shared PERC8 internal firmware 23.14.06.0013 Shared PERC8 external firmware 23.14.06.0013 Internal Expander backplane firmware 2.0 PowerVault MD1200/MD1220 Storage Enclosure firmware 1.06 Microsoft Windows Server 2016 6.805.03.00 Microsoft Windows Server 2012 R2 6.805.03.00 Microsoft Windows Server 2012 6.805.03.00 Microsoft Windows Server 2008 R2 6.805.03.00 VMware ESXi 6.5 U1 6.806.90.00 VMWare ESXi 6.0 U2 6.805.56.00 VMWare ESXi 6.0 U1 6.805.56.00 VMWare ESXi 6.0 Patch 01 6.805.56.00 VMWare ESXi 5.5 U3 6.805.56.00 VMWare ESXi 5.5 U2 6.805.56.00 VMWare ESXi 5.5 U1 6.805.56.00 VMWare ESXi 5.5 6.805.56.00 VMWare ESXi 5.1 U3 6.805.56.00 VMWare ESXi 5.1 U2 6.805.56.00 8 Storage subsystem baseline types

Shared PERC8 OS Driver or Chassis Components firmware Version VMWare ESXi 5.1 U1 6.805.56.00 SLES 12 SP1 6.904.07.00 SLES 12 6.904.07.00 SLES 11 SP4 6.904.07.00 SLES 11 SP3 6.904.07.00 RHEL 7.2 6.904.07.00 RHEL 7.1 6.904.07.00 RHEL 6.8 6.904.07.00 RHEL 6.7 6.904.07.00 RHEL 6.6 6.904.07.00 RHEL 6.5 6.904.07.00 Baseline v5 Shared Storage Expansion through Shared PERC 8 external controllers Table 5. Baseline v5: Shared Storage Expansion through Shared PERC 8 external controllers Shared PERC8 OS Driver or Chassis Components firmware Version CMC firmware 2.1 Chassis Infrastructure firmware 2.21 Shared PERC 8 internal firmware 23.13.16-0013 Shared PERC 8 external firmware 23.13.16-0013 Internal Expander backplane firmware 2.0 PowerVault MD1200/MD1220 Storage Enclosure firmware 1.06 Microsoft Windows Server 2016 6.805.03.00 Microsoft Windows Server 2012 R2 6.805.01.00 Microsoft Windows Server 2012 6.805.01.00 Microsoft Windows Server 2008 R2 6.805.01.00 VMWare ESXi 6.0 U1 6.805.56.00 VMWare ESXi 6.0 Patch 01 6.805.56.00 VMWare ESXi 5.5 U3 6.805.56.00 VMWare ESXi 5.5 U2 6.805.56.00 VMWare ESXi 5.5 U1 6.805.56.00 VMWare ESXi 5.5 6.805.56.00 VMWare ESXi 5.1 U3 6.805.56.00 VMWare ESXi 5.1 U2 6.805.56.00 VMWare ESXi 5.1 U1 6.805.56.00 Storage subsystem baseline types 9

Shared PERC8 OS Driver or Chassis Components firmware Version SLES 12 6.903.05.00 SLES 11 SP4 6.903.05.00 SLES 11 SP3 6.903.05.00 RHEL 7.1 6.903.05.00 RHEL 6.7 6.903.05.00 RHEL 6.6 6.903.05.00 RHEL 6.5 6.903.05.00 Baseline v4 Fault tolerant support for Linux operating systems and bug fixes Table 6. Baseline v4: Fault tolerant support for the Linux operating systems and bug fixes Microsoft Windows Server 2012 R2 Microsoft Windows Server 2012 Microsoft Windows Server 2008 R2 Microsoft Windows Server 2008 SP2 including Hyper-V virtualization VMWare ESXi 6.0 Patch 01 VMWare ESXi 5.5 U2 VMWare ESXi 5.5 U1 Shared PERC 8 FW Shared PERC 8 OS Driver CMC FW Chassis Infrastructure FW Expander FW 23.12.56-0086 6.803.21.00 2.04 2.1 2.0 Yes 23.12.56-0086 6.803.21.00 2.04 2.1 2.0 Yes 23.12.56-0086 6.803.21.00 2.04 2.1 2.0 Yes 23.12.56-0086 6.803.21.00 2.04 2.1 2.0 Yes 23.12.56-0086 6.804.60.00 2.04 2.1 2.0 Yes 23.12.56-0086 6.804.60.00 2.04 2.1 2.0 Yes 23.12.56-0086 6.804.60.00 2.04 2.1 2.0 Yes Dual Controller Support VMWare ESXi 5.5 23.12.56-0086 6.804.60.00 2.04 2.1 2.0 Yes VMWare ESXi 5.1 U3 VMWare ESXi 5.1 U2 VMWare ESXi 5.1 U1 23.12.56-0086 6.804.60.00 2.04 2.1 2.0 Yes 23.12.56-0086 6.804.60.00 2.04 2.1 2.0 Yes 23.12.56-0086 6.804.60.00 2.04 2.1 2.0 Yes 10 Storage subsystem baseline types

Shared PERC 8 FW Shared PERC 8 OS Driver CMC FW Chassis Infrastructure FW Expander FW SLES 12 23.12.56-0086 6.902.57.00 2.04 2.1 2.0 Yes SLES 11 SP3 23.12.56-0086 6.902.57.00 2.04 2.1 2.0 Yes RHEL 7.1 23.12.56-0086 6.902.57.00 2.04 2.1 2.0 Yes RHEL 6.6 23.12.56-0086 6.902.57.00 2.04 2.1 2.0 Yes RHEL 6.5 23.12.56-0086 6.902.57.00 2.04 2.1 2.0 Yes Dual Controller Support Storage subsystem baseline types 11

Updating firmware You can update the PowerEdge VRTX enclosure and server modules installed in the enclosure by using the following interfaces: Windows Dell Update Packages (DUPs) Integrated Dell Remote Access Controller (idrac) web interface PowerEdge VRTX Chassis Management Controller (CMC) web interface RACADM commands The following are the prerequisites for updating the firmware: idrac web interface for each server module is accessible from the management station. Local or remote access to Operating System (OS) management is enabled for each server module. PowerEdge VRTX enclosure CMC web interface is accessible from the management station. All server and enclosure components are in a healthy state. Any issues must be resolved before updating the firmware. 12 Updating firmware

Updating server modules Before updating the server modules, ensure that you download the latest available Windows DUP versions of the following components from Dell.com/support/home: Shared PERC 8 OS driver idrac NOTE: VMware ESXi is part of the Dell ESXi image. CPLD (Complex Programmable Logic Device) BIOS 1 Update the operating system specific Shared PERC 8 driver on all the server modules. NOTE: For Windows and Linux operating systems, see the Shared PERC 8 User s Guide available at Dell.com/support/ home. NOTE: The VMware driver is part of the Dell customized ESXi image. For more information about the VMware drivers, see vmware.com. For more information about installing async drivers, see kb.vmware.com. 2 Update the idrac firmware for each server module by using Windows DUP and the idrac web interface. You can also update the idrac firmware of all the server modules at a time by using the PowerEdge VRTX CMC web interface. NOTE: You must activate the Enterprise license and enable the Extended Storage feature. NOTE: The update process may take several minutes. 3 Update the CPLD on each server module by using Windows DUP and idrac web interface. NOTE: Select the Install and Reboot check box after uploading the DUP. It enables the server module to restart and update the CPLD. The server module is power cycled that results in the idrac web interface being inaccessible for three minutes. 4 Update the BIOS on each server module by using Windows DUP and the idrac web interface. You can also update the BIOS of all the server modules at a time by using the PowerEdge VRTX CMC web interface. NOTE: You must activate the Enterprise license. NOTE: Select the Install and Reboot check box after uploading the DUP. It enables the server module to restart and execute the BIOS update. Updating server modules 13

Updating PowerEdge VRTX enclosure components Download the latest available versions of the following components from Dell.com/support/home: Hard drive firmware (Windows Dell Update Package) CMC firmware PowerEdge VRTX chassis infrastructure firmware PowerEdge VRTX storage backplane expander firmware (Windows DUP) Shared PERC 8 firmware (Windows DUP) NOTE: You must turn off all server modules before updating any enclosure component. To update the PowerEdge VRTX enclosure components, perform the following steps from the CMC Web interface: 1 Click Storage > Update to update the hard drive firmware for each installed shared storage hard drive. 2 Click Chassis Overview > Update to update the CMC firmware. NOTE: Ensure that you update both the CMC firmware by selecting both the Active and Standby controller check boxes. After the firmware update is complete, the CMC restarts. Access to the CMC web interface is lost for several minutes. 3 Click Chassis Overview > Update to update the PowerEdge VRTX enclosure infrastructure firmware. This update results in the PowerEdge VRTX enclosure automatically getting power cycled. CMC reset and the access to the CMC web interface are lost for several minutes. 4 Click Storage > Update to update the PowerEdge VRTX storage backplane expander firmware. 5 Enable all the Shared PERC 8 controllers installed in the enclosure. If the second Shared PERC 8 controller is set to Disabled PERC (Integrated 2), use the CMC command racadm raid enableperc:raid.chassisintegrated.2-1 to enable the disabled controller. PowerEdge VRTX enclosure will execute an enclosure power cycle after running the Shared PERC 8 enablement command. 6 Click Storage > Update to update the Shared PERC 8 controller firmware on all installed controllers. Update both Shared PERC 8 controllers at the same time. NOTE: After the controller firmware update, if you want to disable the second Shared PERC 8 controller for the storage backplane expander firmware update, use the following CMC command: racadm raid disableperc:raid.chassisintegrated.2-1 Executing this command results in an enclosure power cycle. 14 Updating PowerEdge VRTX enclosure components

Documentation resources The following documents are available at the Dell TechCenter and Dell support sites: Integrated Dell Remote Access Controller (idrac) User s Guide RACADM Command Line Reference Guide for idrac and CMC Chassis Management Controller for PowerEdge VRTX User s Guide RACADM Command Life Reference Guide for Chassis Management Controller for PowerEdge VRTX User s Guide Lifecycle Controller User s Guide Lifecycle Controller Remote Services Quick Start Guide Dell PowerEdge VRTX Storage Subsystem Compatibility Matrix Documentation resources 15