Performance Analysis of Power Flow Control Through Statcom, SVC and UPFC

Similar documents
CHAPTER 4 FACTS CONTROLLERS FOR OPTIMIZATION OF POWER SYSTEM

Chapter 3 MODELING OF SHUNT FACTS DEVICES. The Shunt FACTS Devices are used for voltage control and

Simulation and Analysis of Static Var Compensator with Matlab

Voltage Profile Improvement of Transmission Lines Using Static VAR Compensator

Artificial Neural Network Controller With Static VAR Compensator to Improve Transient Stability for A Grid Connected Distributed Generation System

IJSRD - International Journal for Scientific Research & Development Vol. 3, Issue 10, 2015 ISSN (online):

The Study of Voltage Profile and Power Quality with SVC in Transmission System at Different Loads

Transient Stability Improvement of Long Transmission Line System by Using SVC

Modeling and Simulation of Static VAR Compensator Controller for Improvement of Voltage Level in Transmission Lines

Original Contribution EFFECTS OF PARALLEL FACTS CONTROLLERS ON STAEDY STATE VOLTAGE STABILITY MARGIN M. A. Kamarposhti 1 *, H.

Performance analysis of FACTS devices in steady state power flow

POWER FACTOR CORRECTION USING SVC WITH FUZZY LOGIC CONTROLLER

SVC & TCSC for Minmum Operational Cost Under Different Loading Condition

Study of Transient Stability Improvement of IEEE 9-Bus System by using SVC

Power Quality Enhancement using Different FACTS Devices.

Final Report. Mini Project TET Group nr 7 - Project nr 4. Students: Hans Lavoll Halvorson, NTNU

Research Article Development of Inexpensive Static Var Compensator Using PIC

MAHALAKSHMI ENGINEERING COLLEGE TIRUCHIRAPALLI EE-2401 POWER SYSTEM OPERATION AND CONTROL UNIT-III REACTIVE POWER VOLTAGE CONTROL

Voltage Stability assessment by SVC Device Via CPF

Optimal Placement and Sizing of SVC for Improving Voltage Profile of Power System

ISSN: ISO 9001:2008 Certified International Journal of Engineering and Innovative Technology (IJEIT) Volume 7, Issue 1, July 2017

Transient Stability Improvement in Transmission System Using SVC with fuzzy logic Control

MODELING AND SIMULATION OF SVC CONTROLLER FOR ENHANCEMENT OF POWER SYSTEM STABILITY

Transient stability improvement using svc and pss

Power Stability and Oscillation Damping Analysis of a Three Machine Nine Bus System

International Journal of Scientific & Engineering Research Volume 4, Issue 2, February ISSN

Static Var Compensator: Effect of Fuzzy Controller and Changing Membership Functions in its operation

Transient stability of 11-bus system using SVC and improvement of voltage profile in transmission line using series compensator

Analysis of Power System Stability by Using Optimally Located SVC and STATCOM

A Svc Light Based Technique for Power Quality Improvement for Grid Connected Wind Energy System

Optimization of Reactive Power by Using SVC and TCSC Devices for Reducing Transmission Losses

OPTIMAL LOCATION OF SVC USING BENEFIT FACTORS TO IMPROVE THE VOLTAGE PROFILE IN POWER SYSTEMS

Journal of Applied Research and Technology ISSN: Centro de Ciencias Aplicadas y Desarrollo Tecnológico.

IJETST- Volume 01 Issue 09 Pages November ISSN

NYPA FACTS CSC System

Reactive Power Control and Transmission Line Loss Reduction with Realization of FACT Controller

A Novel Approach to Small Signal Stability Enhancement using Fuzzy Thyristor Susceptance control of SVC using Lyapunov Stability

Simulation of FACTS Devices as Reactive Power Compensators and Voltage Controllers in the Smart Grid

Simulation and modeling of grid connected TSC/TSR system using MATLAB

Introduction to new ABB STATCOM portfolio Power Grid Integration FACTS

Reduction of Inrush current in Three Phase Power Transformers using SSSC Device

ANNA UNIVERSITY QB ( )

Optimal Reactive Power Dispatch Using Hybrid Loop-Genetic Based Algorithm

Requirements for Data for Power System Modeling and Analysis (MOD-032-1) Arizona Public Service Company

FACTS and HVDC for Grid Connection of Large Wind Farms

Voltage Collapse Prediction and Voltage Stability Enhancement by Using Static Var Compensator

This section is maintained by the drafting team during the development of the standard and will be removed when the standard becomes effective.

Distribution Static Var Compensators and Static Synchronous Compensators for Suppressing Voltage Fluctuation

Optimal TCSC and SVC Placement for Voltage Profile Enhancement and Loss Minimization Using Bee Colony Optimization

WECC Criterion MOD-(11 and 13)-WECC-CRT-1.1

Lessons Learned in Static VAR Compensator Protection

An Inrush Current Elimination Technique for Line-Interactive UPS Systems During Switching-in of an Auxiliary Load While Feeding a Main Load

DOUBLY-FED ASYNCHRONOUS MACHINE WITH 3-LEVEL VSI FOR VARIABLE SPEED PUMP STORAGE

Study on Power Transformer Inrush Current

A guide on PowerWorld Simulator ver. 12.0

SMUD Model Data Requirements & Reporting Procedures MOD VERSION 1.2

[Kashyap*, 5(2): February, 2016] ISSN: (I2OR), Publication Impact Factor: 3.785

LAB1 INTRODUCTION TO PSS/E EE461: POWER SYSTEMS COLORADO STATE UNIVERSITY

Enhancement of Voltage Stability by Optimal Location of Static Var Compensator Using Genetic Algorithm and Particle Swarm Optimization

Hybrid electromechanical-electromagnetic simulation to SVC controller based on ADPSS platform

Short-Circuit Calculation Methods

Haidar Samet, and Mohammad Amin Jarrahi School of Electrical and Computer Engineering Shiraz University Shiraz, Iran

Optimal Placement of SVC for the Transmission Congestion Management

An Improved Gateway Based Multi Hop Routing Protocol for Wireless Sensor Network

Congestion Management in Deregulated Power System by Fuzzy Based Optimal Location and Sizing of UPFC

CONSCIENCE TECHNOLOGIES A Right Platform For All Engineers... CODE B.TECH EEE MAT LAB PROJECT TITLE

Micro physical simulation system of electric power systems

N-1-1 Reactive Upgrades

Telecommunication of Stabilizing Signals in Power Systems

Optimal Allocation of Distributed Generation (DGs) and Static VAR Compensator (SVC) in a power system using Revamp Voltage Stability Indicator

ETAP PowerStation 4.0

COMPARISON OF OPTIMIZATION TECHNIQUE TO FIND THE OPTIMAL LOCATION OF FACTS CONTROLLERS FOR TRANSMISSION LINE

Christian PAYERL, Poznan, 20 th May, 2009 ABB FACTS Grid connection of Wind Farms. ABB Group May 22, 2009 Slide 1

Modelling and Simulation of the SVC for Power System Flow Studies: Electrical Network in voltage drop

SCADA and Systems Monitoring

POWER FLOW ANALYSIS AND PROTECTION COORDINATION OF REAL TIME SYSTEM

AN ADVANCED APPROACH TO IDENTIFY INRUSH CURRENT AND HARMONICS USING ARTIFICIAL INTELLIGENCE FOR POWER SYSTEM PROTECTION

Main Components of a Static Var Compensator (SVC)

10 th Annual University of Pittsburgh Electric Power Industry Conference

System Studies for American Transmission Co. s Benson Lake SVC Project

Safety Instructions 1-1 Avoid unintended Start General Description 2-2

HVDC Control and Protection Testing Using the RTDS Simulator

ISO New England Data Modeling Requirements

University of California, Santa Cruz Baskin Engineering School Electrical Engineering Department

ABB static var compensator stabilizes Namibian grid voltage

IMPACT OF SVC DEVICES ON DISTANCE PROTECTION SETTING ZONES IN 400 kv TRANSMISSION LINE

Modelling and Simulation of Static VAr Compensator (SVC) in Power System Studies by MATLAB

Re-Dispatching Generation to Increase Power System Security Margin and Support Low Voltage Bus

Effects of Shunt FACTS Devices on MHO Distance Protection Setting in 400 kv Transmission Line

SYMPATHETIC INRUSH PHENOMENA IN PARALLEL AND SERIES CONNECTED TRANSFORMERS USING PSCAD

Intelligent Application of Flexible AC Transmission System Components in an Evolving Power Grid

Distributed Load Flow using Partitioning and Equivalencing of Power Networks

Real Time Digital Simulator Testing of an On Line Integrated Stability Control System

p. 1 p. 9 p. 26 p. 56 p. 62 p. 68

OPTIMAL MONITORING AND VISUALIZATION OF STEADY STATE POWER SYSTEM OPERATION. A Dissertation BEI XU

Minimization of Power Loss and Voltage Deviation by SVC Placement Using GA.

Modeling and Simulation in XENDEE

Enhancement Voltage Stability of the Iraqi Power Grid Using Shunt FACTs Devices

Transmission Distribution Microgrid - DER

Effective Management of Transformer Inrush during Restoration of a Typical Industrial Power System

Transcription:

Volume-4, Issue-, February-204, ISSN No.: 2250-0758 International Journal of Engineering and Management Research Available at: www.ijemr.net Page Number: 84-89 Performance Analysis of Power Flow Control Through Statcom, SVC and UPFC Krishan Kumar, Varinder Goyal 2 M.Tech (Student), EE Section, GTBKIET Chhapianwali, Malout, Punjab Technical University, Jalandher, INDIA 2 Assistant Professor, EE Section, GTBKIET Chhapianwali, Malout, Punjab Technical University, Jalandher, INDIA ABSTRACT This paper presents, Performance Analysis of power flow control through FACTS Devices in Power System. In a power system network consisting of generators, transmission lines, transformers and load etc., STATCOM, SVC and UPFC are applied between two buses separately and their effects are analyzed as par applied system conditions. Power flow between different buses and voltage regulation of above FACTS devices is found out. Simulation of the system was carried out in Matlab environment. In this analysis system was simulated by introducing reference power at the bus where UPFC is connected. UPFC injects series voltage in line and follows reference power as required. SVC and STATCOM are simulated in voltage regulation mode where a reference voltage is given at the bus to which they are connected. Their voltage regulation capabilities and reactive power compensation ability is analyzed. Keywords STATCOM, SVC, UPFC, Power System I. INTRODUCTION Transmission lines in congested areas are often driven increased electric power consumption and trades. Thus, secure operation and reliable supply is endangered by the higher risks for faulted lines. FACTS devices are able to influence power flows and voltages to different degrees depending on the type of the device. If the reactive power of the load is changing rapidly, then a suitable fast response compensator is needed. Static VAR Compensator (SVC), STATCOM and UPFC are such compensators which belong to FACTS family. The ultimate objective of applying reactive shunt compensation in the line is to improve the voltage profile. The inclusion of the FATCS devices in the circuit improves the reactive power in the line. FACTS are successfully simulated and the results show the voltage profile improvement. [] Flexible alternating current transmission systems (FACTS) technology opens up new opportunities for controlling power and enhancing the usable capacity of present, as well as new and upgraded lines. The Unified Power Flow Controller (UPFC) is a second generation FACTS device, which enables independent control of active and reactive power besides improving reliability and quality of the supply. [2] The power flow over a transmission line depends mainly on three important parameters, namely voltage magnitude of the buses (V), impedance of the transmission line (Z) and phase angle between buses (θ). The FACTS devices control one or more of the parameters to improve system performance by using placement and coordination of multiple FACTS controllers in large-scale emerging power system networks to also show that the achieve significant improvements in operating parameters of the power systems such as small signal stability, transient stability, damping of power system oscillations, security of the power system, less active power loss, voltage profile, congestion management, quality of the power system, efficiency of power system operations, power transfer capability through the lines, dynamic performances of power systems, and the loadability of the power system network also increased. As FACTS devices are fabricated using solid state controllers, their response is fast and accurate. Thus these devices can be utilized to improve the voltage profile of the system by using coordinated control of FACTS controllers in multi-machine power systems in this work. [3, 4] 84

II. CONTROL SYSTEM AND MODELLING Control system and modelling of SVC and the AC voltage regulator (in voltage control mode). The current regulator is assisted by a feed forward type regulator which predicts the V2 voltage output (V2d V2q) from the V measurement (Vd Vq) and the transformer leakage reactance. Control System block diagram is shown in Fig.2 Fig. Single-line diagram of an SVC and Its Control System Block Diagram The control system consists of a measurement system measuring the positive-sequence voltage to be controlled. A Fourier-based measurement system using a one-cycle running average is used. A voltage regulator that uses the voltage error (difference between the measured voltage Vm and the reference voltage Vref) to determine the SVC susceptance B needed to keep the system voltage constant. A distribution unit that determines the TSCs (and eventually TSRs) that must be switched in and out, and computes the firing angle α of TCRs A synchronizing system using a phase-locked loop (PLL) synchronized on the secondary voltages and a pulse generator that send appropriate pulses to the thyristors.[5] Control system and modelling of STATCOM The control system consists of a phase-locked loop (PLL) which synchronizes on the positive sequence component of the three phase primary voltage V. The output of the PLL (angle θ=ωt) is used to compute the direct axis and quadrature axis components of the AC three phase voltage and currents (labeled as Vd, Vq or Id, Iq on the diagram). Measurement systems measuring the d and q components of AC positive sequence voltage and currents to be controlled as well as the DC voltage Vdc.[0] The output of the AC voltage regulator is the reference current Iq ref for the current regulator (Iq = current in quadrature with voltage which controls reactive power flow). The output of the DC voltage regulator is the reference current Id ref for the current regulator(id = current in phase with voltage which controls active power flow).an inner current regulation loop consisting of a current regulator. The current regulator controls the magnitude and phase of the voltage generated by the PWM converter (V2d V2q) from the Id ref and Iq ref reference currents produced respectively by the DC voltage regulator Fig.2 Single-line Diagram of a STATCOM and Its Control System Block Diagram Control system and modelling of UPFC Although the UPFC has many possible operating modes, it is anticipated that the shunt inverter will generally be operated in automatic voltage control mode and the series inverter will typically be in automatic power flow control mode. Accordingly, block diagrams are shown in Fig.3 and Fig.4, giving greater detail of the control schemes for each inverter operating in these modes. These control schemes are typical but they may vary in detail from one installation to another. Also, for clarity, only the most significant features are shown and less important signal processing and limiting has been omitted. The control schemes assume that both the series and shunt inverters generate output voltage with controllable magnitude and angle, and that the dc bus voltage will be held substantially constant. [6, 7] Fig.3 Block Diagram of Shunt Inverter Control 85

The automatic power flow control for the series inverter is achieved by means of a vector control scheme that regulates the transmission line current, using a synchronous reference frame in which the control quantities appear as dc signals in the steady state The appropriate reactive and real current components are determined for a desired Pref and Qref compared with the measured line currents, and used to drive the magnitude and angle of the series inverter voltage. The series injected voltage limiter in the forward path of this controller that takes account of practical limits on series voltage. [8] A vector control scheme is also used for the shunt inverter.in this case the controlled current is the current delivered to the line by the shunt inverter. In this case, however, the real and reactive components of the shunt current have a different significance.the reference for the reactive current, iq shunt, is generated by an outer voltage control loop, responsible for regulating the ac bus voltage, and the reference for the real-power bearing current, ip shunt, is generated by a second voltage control loop that regulates the dc bus voltage.in particular, the real power negotiated by the shunt inverter is regulated to balance the dc power from the series inverter and maintain a desired bus voltage. The dc voltage reference, Vdc may be kept substantially constant.for the shunt inverter the most important limit is the limit on shunt reactive current as a function of the real power being passed through the dc bus.this prevents the shunt inverter current reference from exceeding its maximum rated value. The control block diagrams shown in Fig.3 and Fig.4 are only a small part of the numerous control algorithms that are needed for all the operating modes of the UPFC, and for protection and sequencing. The control system typically incorporates many sophisticated computers and extensive electronics.[9] Voltage Regulation In the Fig.5 results of applied reference voltage and measured reference voltage at SVC Bus is shown. Here SVC shows its voltage regulation capability. Fig.5 Reference Voltage and measured voltage at SVC Bus. In Fig.6 Reactive power supplied by SVC is shown during voltage regulation. Qmeasured [pu].04.03.02.0.2 0.8 0.6 0.4 0.2 0 Voltage regulation by SVC at its bus Reactive power compensation by SVC at its bus Reference Voltage Measured Voltage reactive power by SVC -0.2 Fig.6 Reactive power supplied by SVC during voltage regulation STATCOM Simulation Results Simulation results of STATCOM are shown in Fig.7 when it is connected to Bus B. Voltage at statcom Bus B Fig.4 Block diagram of series inverter Control.02 III. SVC Simulation Results SIMULATION RESULTS SVC acts basically in Voltage Regulation and VAR control mode.for the selected power system network, result of Voltage Regulation mode has been found out. [0, ] 0.94 0.92 86

Fig.7 STATCOM connected at Bus B Fig.0 STATCOM connected at Bus B 4 Voltage Regulation at Bus B 2 Simulation results of STATCOM are shown in Fig.8 when it is connected to Bus B 2. Fig.8 STATCOM connected at Bus B Voltage Regulation at Bus B 3 Simulation results of STATCOM are shown in Fig.9 when it is connected to Bus B 0.95 Time [sec ].03.02.0.03.02.0 0.95 3. Voltage at statcom bus B2 Fig.9 STATCOM connected at Bus B Voltage Regulation at Bus B 4 Simulation results of STATCOM are shown in Fig.0 when it is connected to Bus B 4 2. 3. 0.94.03.02.0 Voltage at statcom Bus B3 Voltage at statcom bus B4 Voltage Regulation at Bus B5 Simulation results of STATCOM are shown in Fig. when it is connected to Bus B.05.0.005 5 5 5 Voltage at statcom bus B5 Time [sec ] Fig. STATCOM connected at Bus B5 Simulation Results of UPFC UPFC simulation results for change in active power demand, reactive power demand and corresponding value of magnitude and phase angle of injected voltage are found out. [2, 3] Simulation results for step like changes in Active Power at UPFC Bus Fig.2 shows step like change in reference active power and response of UPFC to meet this demand. Active Power P[pu] 7 6.8 6.6 6.4 6.2 6 5.8 5.6 5.4 5.2 Power flow control with UPFC for step like changes in active power at UPFC Bus Fig.2 Reference active power with measured active power at UPFC Bus 5. reference power measured power 5 0 2 4 6 8 0 2 4 6 8 20 0.95 Time [sec ] Simulation results for step like changes in Reactive Power at UPFC Bus. Fig.3 shows step like change in reference reactive power and response of UPFC to meet this demand. 87

Fig.3 Reference reactive power with measured active power at UPFC Bus Simulation results for UPFC injected Voltage Magnitude and phase angle. Fig.4 and Fig.5 shows UPFC injected voltage magnitude and phase angle to meet the demand in active and reactive power. voltage phase angle [degree] by UPFC Rective Power Q [pu] 04 02 00 98 96 94 92-0.05-0. -0.5-0.2-0.25-0.3-0.35-0.4-0.45-0.5 0 2 4 6 8 0 2 4 6 8 20 Voltage magnitude [pu] injected by UPFC 0 0. 0.08 0.06 0.04 0.02 Power flow control with UPFC for step like changes in reactive power at UPFC Bus Voltage magnitude injected by UPFC to meet active power and reactive power demand Fig.4 Voltage magnitude injected by UPFC Fig.5 Phase angle of injected series voltage at UPFC Bus IV.Active and Reactive Power Flow Comparison For the given power system network power flow comparison is being carried out. When UPFC is not connected to the system transformer2 of 800 MVA capacity is overloaded by 99.UPFC handles this congestion situation and relieves transformer 2 to draw only 796 through it. It forces UPFC Bus to draw extra active power through it. Table. Comparison of active and reactive power flow with and without UPFC reference reactive power measured reactive power 0 0 2 4 6 8 0 2 4 6 8 20 Phase angle of injected series voltage by UPFC Voltage injected by UPFC phase angle of UPFC injected voltage 90 0 2 4 6 8 0 2 4 6 8 20 S.No UPFC B B 2 B 2B 3 B 3B 5 B 4B 5 B 4B 5+ B 3B 5 Not Connected 95.9-6.4 2 Connected 96.6-3.82 588.8-63.69 689.7-99.45 586.8-26.83 687-37 898.6 26.72 796 8 279-05.6 277-97. Thus results in above table of UPFC is showing relieve in congestion between BUS B 4 and BUS B 5 and now transformer2 is not overloaded. V. CONCLUSIONS UPFC can control active and reactive power flow in transmission lines. SVC and STATCOM improves system voltage stability. Voltage regulation mode of SVC and STATCOM is successfully simulated in MATLAB. Simulation results are good and they are accepted. UPFC can control active power and reactive power independently. Series compensator of UPFC can be operated in power flow control mode and simultaneously shunt compensator may be operated in voltage regulation or var control mode. Similarly, simulations carried out showed that SVC and STATCOM provides excellent voltage regulation, power factor and active power regulation capabilities. REFERENCES [] Narain G. Hingurani and Laszlo Gyugyi, Understanding FACTS technology of Flexible AC Transmission Systems, IEEE Press 2000. [2] Y.H. Song, Flexible ac transmission systems (FACTS), London: The Institution of Electrical Engineers, 999. [3] Bindeshwar Singh, K.S. Verma, Deependra Singh, C.N. Singh, Archna Singh, Ekta Agrawal, Rahul Dixit, Baljiv Tyagi, Introduction to FACTS controllers a critical review, International Journal of Reviews in Computing 3st December 20 Vol. 8, 20. [4] Bhanu Chennapragada, Venkata Krishna, Kotamarti, S. B.Sankar, Pindiprolu, V. Haranath, Power System Operation and control using FACT devices, 7th International Conference on Electricity Distribution Barcelona, 2-5 May 2003. 88

[5] M.Arun Bhaskar, C.Subramani, M.Jagdeesh Kumar and Dr.S.S.Dash, Voltage Profile Improvement Using FACTS Devices: A Comparison between SVC, TCSC and TCPST, International Conference on Advances in Recent Technologies in Communication and Computing 2009. [6] Mehrad Ahmadi Kamarposhti, Mostafa Alinezhad, Hamid Lesani and Nemat Talebi, Comparison of SVC, STATCOM, TCSC, and UPFC Controllers for Static Voltage Stability Evaluated by Continuation Power Flow Method, IEEE Electrical Power & Energy Conference 2008. [7] L.Gyugyi, C.D.Schauder, S.L.Williams, T.R.Rietman, D.R.Torgerson and A.Edris, The Unified Power Flow Controller: A new Approach to Power Transmission Control, IEEE Transaction on Power Delivery, Vol. 0, No. 2, April 995. [8] Zhengyu Huang,Yixin Ni,C.M. Shen, Felix F. Wu, Shousun Chen and Baolin Zhang, Application of Unified Power Flow Controller in Interconnected Power Systems Modeling,Interface,Control Strategy, and Case Study. IEEE Transaction on Power Systems, Vol. 5, No. 2, May 2000. [9] Y. Pannatier, B. KawKabani and J.J. Simod, Modeling and Transient Sim-ulation of FACTS in Multi-Machine Power Systems, Proceedings of the 2008 International Conference on Electrical Machines, 2008. [0] A.J.F. Kesri, A.S.Mehraban, X.Lombard, A.Elriachy and A.A.Edris, Unified Power Flow Controller (UPFC): Modeling and Analysis, IEEE Transaction on Power Delivery, Vol. 4, No. 2, April 999. [] I. Papic, P. Zunko, D. Povh and M. Weinhold, Basic Control of Unified Power Flow Controller, IEEE Transactions on Power Systems, Vol. 2, No. 4, November 997. [2] S D Round, Q Yu, L E Norum and T M Undeland, Performance of a unified power flow controller using a D-Q control system AC and DC Power Transmission, 29 April-3 May 996, Conference Publication No. 423 copyright IEE, 996. [3] Kumara Deepak, G.Saravana Ilangol, C.Nagamani and K. Shanti Swarup, Perform- ance of UPFC on System Behavior under Fault Conditions, IEEE Indicon 2005 Conference, Chennai, India, - 3 Dec. 2005. Copyright 20-4. Vandana Publications. All Rights Reserved. 89