LAUREL. Laureate Pulse or Analog Input Batch Controller Automatic batch control for repetitive liquid fill operations ELECTRONICS, INC.

Similar documents
LAUREL ELECTRONICS, INC.

LAUREL. Laureate Dual-Channel Pulse Input Totalizer With Two Independently Scalable Input Channels & Presets ELECTRONICS, INC. Features.

LAUREL. Laureate Rate Meter & Totalizer with Functions A+B, A-B, AxB, A/B, A/B-1 ELECTRONICS, INC. Features. Description

Y800 Plus Frequency, Rate & Period Meter With dual, independently field-scalable channels

LAUREL. Laureate Digital Panel Meter for Process and Ratiometric Signals ELECTRONICS, INC. Features. Description

TC Type Range Conformity Error. J -210 C to +760 C (-347 F to F) ±0.09 C (±0.16 F) K -244 C to C (-408 F to F) ±0.1 C (±0.

LAUREL. Laureate RTD Temperature Panel Meter / Controller ELECTRONICS, INC. Features. Description. Specifications

LAUREL ELECTRONICS, INC.

LAUREL. Laureate Digital Panel Meter for Load Cell & Microvolt Input ELECTRONICS, INC. Features. Description

Laurel Electronics Customer Price List

LAUREL. MAGNA Series Large Digit Displays for Counter / Totalizer Pulse Input ELECTRONICS, INC. Features. Description

1.6. Counters, Panel Meters, Tachometers and Timers. Contents Description Fusion Integrated Machine Control Standards and Certifications...

Digital Indicator Solutions

MICRO SERIES PROCESS DISPLAYS LARGE DIGIT MODELS

Panel Indicators. NEW 4~20mA Panel Display. Process Indicators INTECH INSTRUMENTS.

PT2060 Monitor. PT2060/91 SIM System Interface Module. Specifications. Electrical. Messtechnik

Batch Controller with numerical keypad, remote control inputs and 3 control / alarm / pulse outputs

Product Description. Contents. Fusion Series. New Information December 2003

MICROFUSION FEATURES OPTIONS CERTIFICATIONS (PENDING) THREE PHASE SCR POWER CONTROLLERS

MPI-DN, MPI-D MULTICHANNEL ELECTRONIC RECORDER for HART or RS-485/ MODBUS RTU SENSORS

Amplifiers, Counters, Timers & Controls

The PM1000 series is a universal 4 digit LED plug-on display for transmitters with 4-20mA 2 wire output and fitted with DIN43650 connector.

DTS 310. DIN Rail Mounted, Indoor Rated Revenue Grade Electrical Sub-meter. Page 1. Measurlogic MQ A

Line A. Inverse parallel scrs. Load a FUSION. Line B SCR POWER. O delta CONTROLLERS. Line c. inverse parallel scrs. Load C. FUSION Brochure Rev 3.

RS 485 Mini Modbus 1AO

SINGLE-CHANNEL PROCESS CONTROLLERS & TEMP. DISPLAYS D3820/D3830 Series

D7000 SERIES MODBUS TCP/IP ETHERNET INTERFACE MODULES

I-7520: RS-232 to RS-485. Input: RS-232 protocol Output:RS-485/RS-422 Speed: Self Tuner 'inside, auto switching baud rate, 300~ BPS

User friendly and easy to program

Displays Transducers. Displays and transducers

Universal counter UZ 9648 Counting - length measurement - metering - positioning

DI-942MB. Frequency/Counter Module. Two Frequency or Pulse Waveform Inputs

MPV. Process Panel Display. Dual-Line Rate and Total

Digital Frequency Divider INSTRUCTION MANUAL CONTENTS. 1. Working Principle Installation Setting Up Technical Data 4.

Measurement Systems Datascan Installation and User Guide

SPECIFICATIONS SPECIFICATIONS. Input VDC. NEMA 4X/IP65 front VDC option. Temp SPECIFICATIONS

NF760 Batch Controller

PM174 PM174 IEEE1159 ADVANCED POWER QUALITY ANALYZER. Features

KRAL Electronics BEM 300 and BEM 500.

D1000M SERIES FOR MODBUS SENSOR TO COMPUTER INTERFACE MODULES

Omega and Red Lion team-up!

1/32-DIN TEMPERATURE CONTROLLER INSTALLATION, WIRING AND OPERATION MANUAL FORM 3882

NF770 Temperature Compensation Liquid Flow Computer

7511 / / / 711 / / 731 / Preset 27

DRTS 3 PLUS Advanced Protection Relay Test Set and Measurement System

The IQ300 wall mount load cell indicator is a precision digital indicator for load cell and strain gauge applications.

PD6210 / PD6310. PROVU Dual-Line 6-Digit Batch Controllers. Batch control SERIES. Precision Digital Corporation

DKG-210 UNIVERSAL INTERNET GATEWAY UNIT

8B SLX300 Data Acquisition System

PD6210 / PD6310. PROVU Dual-Line 6-Digit Batch Controllers BATCH CONTROL. PRECISION DIGITAL CORPORATION SERIES

OTB1S0DM9LP I/O distributed module OTB - Modbus non isolated serial link m

PID with. Controllers W A T L O W CPC400 SERIES. Multi-Loop

LGR-5325 Specifications

ADAM-6200 Series. Feature. Transition and Vision on Remote DAQ Device 19-13

DTM Distributed Transmitter Monitor

Simplified information where and how you want it.

02/11/2015

Process displays For current and voltage

DXP-40 FEATURES APPLICATIONS DESCRIPTION CONFIGURATION

MP-2000 Dual Channel LVDT/RVDT Readout/Controller

The IQ240 panel mount load cell indicator is a precision digital indicator for load cell and strain gauge applications.

DIGITAL DISPLAY. for Industry Applications. Series PAXD. Key-Features:

EDX-10 Series. Compact Recording System

smart meters... 6 panel meters... 7 field displays... 8 display types loop powered displays TRANSMITTERS & CONVERTERS...

LBVR1718. Description. Features channel paperless recorder

L40 UNIVERSAL ANALOG INPUT DIGITAL PANEL METER OWNERS MANUAL

OTB1S0DM9LP I/O distributed module OTB - Modbus non isolated serial link m

Zelio Count - Counters RC87610

RS485 MODBUS Module 8I8O

FUSION COMPACT. Load a. Line A. Inverse parallel scrs. Line B. Line c. inverse parallel scrs. Load C SCR POWER. O delta CONTROLLERS

Multifunction Transducer MT440

VersaMax Micro and Nano Technical Product Presentation

RS-485 I/O Modules: ADAM-4000

SDM-8I8O. Expansion Module 8 digital inputs, 8 digital outputs. Manufactured for

INTEGRATED SYSTEMS AND CONTROL, INC. User s Hardware Manual. PCMNET V 7. xx

Custom ASCII Protocol

5450 NW 33rd Ave, Suite 104 Fort Lauderdale, FL Fruitland Ave Los Angeles, CA SST7000 SST7100. Speed Switch / Transmitter

Self-Powered Wireless Instrumentation

02/11/2015

Energy Management Modular Energy meters Type EM2-96

Isolated Process Current Input 7B32 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Isolated Process Current Input with Loop Power 7B35

Dual Channel Monitor for Measurement of Speed and Ratio with SIL1 requirements Series D224.xx

PRODIS. PD-ADC Digital Process Meter for analog Sensors. Digital Process Meters. Datasheet

INSTALLATION INSTRUCTIONS

CATALOG SHORT FORM. Digital Indicators & Controllers. th ANNIVERSARY PRECISION DIGITAL CORPORATION Since 1974

Isolated Wideband Voltage Input 3B40 / 3B41 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

RS485 IO Slim Module MOD-ETH

Family of Water Cut Analyzers

Level Measurement Continuous level measurement - Ultrasonic controllers

Si 2035 Programmable Stepper Drive

SORDS ELECTRIC ~ MA7200. Sensorless Vector AC Inverter.

Wide Bandwidth Strain Gage Input 3B18 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Level Measurement Continuous level measurement Ultrasonic controllers

DIGITAL PANEL METERS

TRACKER 240 SERIES. Load Cell and Weighing Indicators. A Precision Measurement Instrument with Outstanding Features

DI-917MB/DI-918MB. Heavy-duty 1A solid-state relays provide dependable on/off control of industrial devices. Analog Output Module. Four Analog Outputs

Batch Controller with numerical keypad and receipt printer driver

PENKO Engineering B.V. When Weighing Counts FLEX Multi Channel Extended

S-Line HIGH BRIGHTNESS AND ACCURACY DIGITAL LED INDICATORS MODULAR INDICATORS / TOTALIZERS WITH UNIVERSAL ANALOG INPUT

Transcription:

Description LAUREL ELECTRONICS, INC. Laureate Pulse or Analog Input Batch Controller Automatic batch control for repetitive liquid fill operations Features Available for turbine flow meter pulse signals from 0 Hz to 1 MHz or analog flow meter signals (4-20 ma, 0-1 ma or 0-10V) Selectable display of batch total, grand total, number of batches, or flow rate 6-digit LED display scalable to ±999,999 Counts up from 0 to preset or down from preset to 0 Universal AC power, 85-264 Vac Isolated 5, 10 or 24 Vdc excitation supply to power sensors NEMA 4X, 1/8 DIN case Choice of relay outputs: 2 or 4, contact or solid state Optional serial I/O: Ethernet, USB, RS232, RS485, Ethernet-to-RS485 converter Optional isolated analog output: 4-20 ma, 0-20 ma, 0-10V, -10 to +10V Optional low voltage power: 10-48 Vdc or 12-32 Vac The Laureate batch controller is a low cost, powerful and highly accurate batching controller for repetitive fill operations. It can use the Laureate FR dual channel pulse input signal conditioner for use with turbine flow meters, or the Laureate V-to-F analog signal conditioner for use with 4-20 ma, 0-1 ma or 0-10V conditioned flow meter signals. Relay control can be provided by two or four 8A contact relays, or by two or four 120 ma AC/DC solid state relays. Fill operations are repeated continually with a programmable delay from 10 ms to 199.99 sec, or based on an external control input. Three items are tracked by the batch control software. These can each be scaled to engineering units of total or flow rate and displayed by the controller's six-digit LED display: Item #1 is the current batch total, which can be set up to count up from zero to a preset limit, or down from a preset limit to zero. Item #2 can be assigned to grand total or number of batches. Item #3 is the flow rate. Two or four relays can be used. Relay #1 is assigned to batch total to control the filling operation. Relays #2, #3 and #4 can each be assigned by the user to Items #1, #2 or #3. For example, Relay #2 can be assigned to Item #1 (batch total) with a lower setpoint to serve as a pre-warn and slow down the fill rate near the batch setpoint, and Relay #3 can be assigned to the total number of batches to terminate the batching when a present number of bottles have been filled. An optional serial communications board allows the batch controller to transmit Items #1, #2 and #3, as well as peak for item #3 (rate). If required, all four items can be displayed simultaneously by augmenting the batch controller with up to three Laureate remote displays. Each of these can have its own analog output and relays for alarm or control. Batch Control with Turbine Flowmeters The pulse-input batch controller utilizes the FR dual channel signal conditioner, which accepts pulses from turbine flow meters and most industrial transducers with a pulse output such as proximity switches with PNP or NPN output, TTL or CMOS logic, or magnetic pickup pulses down to 12 mv. The same signal is applied in parallel to the A and B input channels, which are used independently. Either channel can accept pulse rates from 0.005 Hz to 250 khz, which exceeds the working range of turbine flow meters. Channel A is used for totalizing. The measured total is scaled mathematically for control and display of volume in engineering units, such as liters. Channel B is used for rate. Pulse frequency is determined by timing an integral number of periods over a specified gate time (plus 30 ms and 0-2 periods), and then taking the inverse of period. The inverse period approach allows greater accuracy and faster update times than conventional rate meters which count signal pulses over a specified time interval. Update times can be up to 25/sec. Rate in engineering units, such as liters per second, is obtained by multiplying the input by a scale factor. Batch Control with Conditioned Flow Signals The analog input batch controller utilizes the Laureate VF voltage-to-frequency converter signal conditioner board, which converts 4-20 ma, 0-1 ma or 0-1V conditioned flow meter signals to a frequency from 10 khz to 110 khz. This allows the counter controller to totalize flow, to count up to a preset value, or to count down to zero from a preset value for batch control. One of the relays is dedicated to On/Off batch control, while the other relay is available to slow down rate near the setpoint or to provide another alarm or control function based on rate or total. Designed for system use. Available plug-in boards include Ethernet and other serial communication boards, dual or quad relay boards, and an isolated analog output board. Laureates may be powered from 85-264 Vac or optionally from 12-32 Vac or 10-48 Vdc. The display is available with red or green LEDs. The 1/8 DIN case meets NEMA 4X (IP65) specifications from the front when panel mounted. Any setup functions and front panel keys can be locked out for simplified usage and security. A builtin isolated 5, 10, or 24 Vdc excitation supply can power transducers and eliminate the need for an external power supply. All power and signal connections are via UL / VDE / CSA rated screw clamp plugs. LAUREL ELECTRONICS INC., 3183-G Airway Ave., Costa Mesa, CA 92626, USA Tel 714-434-6131 www.laurels.com 1

Specifications Display Readout Display Range Zero Adjust Span Adjust Indicators 6 LED digits, 7-segment, 14.2 mm (.56"), red or green -999999 to +999999, XXXXEX scientific notation beyond 999999-999999 to +999999 0 to 999999 Four LED lamps Pulse Inputs (FR signal conditioner) Signal Types Ch A Frequency, Max Ch B Frequency, Max Signal Ground Minimum Signal Maximum Signal Maximum Frequency Conversion Technique Delay between batches AC, pulses from NPN, PNP transistors, contact closures, magnetic pickups. 1 MHz 250 khz Common ground for channels A & B Nine ranges from (-12 to +12 mv) to (+1.25 to +2.1V) 250 Vac 1 MHz, 30 khz, 250 Hz (selectable) Inverse period Selectable 10 ms to 199.99 s Analog Input (V-to-F signal conditioner) Signal Types Conversion Technique Update Rate Gate Time 0-1 ma, 4-20 ma, 0-10V Inverse period applied to 10 khz- 110 khz 50 ms (max) Selectable 10 ms to 199.99 s Power Voltage, standard Voltage, optional Power frequency Power consumption (typical, base meter) Power isolation 85-264 Vac or 90-300 Vdc 12-32 Vac or 10-48 Vdc DC or 47-63 Hz 1.2W @ 120 Vac, 1.5W @ 240 Vac, 1.3W @ 10 Vdc, 1.4W @ 20 Vdc, 1.55W @ 30 Vdc, 1.8W @ 40 Vdc, 2.15W @ 48 Vdc Excitation Output (standard) 5 Vdc 10 Vdc 24 Vdc Output 5 Vdc ± 5%, 100 ma 10 Vdc ± 5%, 120 ma 24 Vdc ± 5%, 50 ma 50 Vdc to meter ground Analog Output (optional) Output Levels Current compliance Voltage compliance Scaling Resolution 4-20 ma, 0-20 ma, 0-10V, -10 to +10V (single-output option) 4-20 ma, 0-20 ma, 0-10V (dual-output option) 2 ma at 10V ( > 5 kω load) 12V at 20 ma ( < 600 Ω load) Zero and full scale adjustable from -99999 to +99999 16 bits (0.0015% of full scale) (dual analog outputs share the same ground) Relay Outputs (minimum of 2 relays required) Relay Types Current Ratings Output common 2 Form C contact relays or 4 Form A contact relays (NO) 2 or 4 Form A, AC/DC solid state relays (NO) 8A at 250 Vac or 24 Vdc for contact relays 120 ma at 140 Vac or 180 Vdc for solid state relays Isolated commons for dual relays or each pair of quad relays Serial Data I/O (optional) Board Selections Protocols Data Rates Ethernet, Ethernet-to-RS485 server, USB, USB-to-RS485 server, RS485 (dual RJ11), RS485 Modbus (dual RJ45), RS232. Modbus RTU, Modbus ASCII, Laurel ASCII protocol 300 to 19200 baud LAUREL ELECTRONICS INC., 3183-G Airway Ave., Costa Mesa, CA 92626, USA Tel 714-434-6131 www.laurels.com 2

Digital Addresses 247 (Modbus), 31 (Laurel ASCII), Environmental Operating Temperature Storage Temperature Relative Humidity Protection 0 C to 55 C -40 C to 85 C 95% at 40 C, non-condensing NEMA-4X (IP-65) when panel mounted Signal Connections Mechanical LAUREL ELECTRONICS INC., 3183-G Airway Ave., Costa Mesa, CA 92626, USA Tel 714-434-6131 www.laurels.com 3

Application Examples Drum Filling Application Utilizing Two Relay Outputs In this drum filling application, the Laureate pulseinput batch controller utilizes uses its two relays to control a pump. The Prewarn relay slows down the pump near the preset to avoid overshoot. The Batch relay stops the pump at the preset. Controlling Chemical Mixing of Materials Multiple Laureate batch controllers can be used in combination to control the mixing of materials in the proper ratio. Each feed line is equipped with its own pump, flowmeter, and Laureate. Controller setup and monitoring of the mixing operation are facilitated by optional serial communications. RS-485 allows a single data line to handle multiple controllers. Up-Counting & Down-Counting Batch Control In up-counting batch control, the Laureate counts up from zero to a preset maximum. A prewarn level is available to slow down filling near the preset to avoid overshoot. A time delay can be programmed from the end of each batch to the start of the next batch. In down-counting batch control, the Laureate counts down from the preset maximum to zero. A prewarn level is available to slow down filling or emptying near zero. Again, a time delay can be programmed from the end of each batch to the start of the next batch. Discrete Filling and Batch Counting The Laureate batch controller is ideal for discrete manufacturing as well as repetitive fill operations. In this example, the Laureate counts bottles which it then groups into sixpacks. Its Grand Total capability can be used to track bottles or sixpacks. LAUREL ELECTRONICS INC., 3183-G Airway Ave., Costa Mesa, CA 92626, USA Tel 714-434-6131 www.laurels.com 4

Ordering Guide Create a model number in this format: L70100FR, IPC Main Board Power Relay Output Analog Output Digital Interface Input Type L7 Extended Main Board, Green LEDs L8 Extended Main Board, Red LEDs 0 Isolated 85-264 Vac 1 Isolated 12-32 Vac or 10-48 Vdc 1 Two 8A Contact Relays 2 Two 120 ma Solid State Relays 3 Four 8A Contact Relays 4 Four 120 ma Solid State Relays 1 Single isolated 4-20 ma, 0-20 ma, 0-10V, -10 to +10V 2 Dual isolated 4-20 ma, 0-20 ma, 0-10V 1 RS232 2 RS485 (dual RJ11 connectors) 4 RS485 Modbus (dual RJ45 connectors) 5 USB 6 USB-to-RS485 converter 7 Ethernet 8 Ethernet-to-RS485 converter Pulse Rate or Totalizing FR Dual-Channel Pulse Input Signal Conditioner Voltage-to-Frequency Converter VF1 V-to-F Converter, 4-20 ma VF2 V-to-F Converter, 0-1 ma VF3 V-to-F Converter, 0-10 V VF4 V-to-F Converter, Special Range For special range, specify min input, min reading; max input, max reading. Component changes by the factory may be required. Add-on Options CBL01 RJ11-to-DB9 cable. RJ11 to DB9. Connects RS232 ports of meter and PC. CBL02 USB-to-DB9 adapter cable. Combination of CBL02 and CBL01 connects meter RS232 port to PC USB port. CBL03-1 6-wire data cable, RJ11 to RJ11, 1 ft. Used to daisy chain meters via RS485. CBL03-7 6-wire data cable, RJ11 to RJ11, 7 ft. Used to daisy chain meters via RS485. CBL05 CBL06 CASE1 CASE2 IPC BOX1 BOX2 BL NL USB cable, A-B. Connects USB ports of meter and PC. USB to RS485 adapter cable, half duplex, RJ11 to USB. Connects meter RS485 port to PC USB port. Benchtop laboratory case for one 1/8 DIN meter Benchtop laboratory case for two 1/8 DIN meters Splash-proof cover NEMA-4 Enclosure NEMA-4 enclosure plus IPC Blank Lens without button pads Meter lens without button pads or Laurel logo LAUREL ELECTRONICS INC., 3183-G Airway Ave., Costa Mesa, CA 92626, USA Tel 714-434-6131 www.laurels.com 5