ETHERNET/MFC 010 Technical Datasheet

Similar documents
UFD 5. Display for ALTOSONIC 5. Technical Datasheet. Configurable display for ALTOSONIC 5 Easy installation Durable design

IFC 100 Supplementary instructions

User Manual Gateway component for EtherNet/IP

SK CU4-EIP-C Part number:

Anybus Communicator STARTUP GUIDE. IIoT. SP en-us ENGLISH

LS 6600 Technical Datasheet

OPTICHECK Technical Datasheet

OPTICHECK Technical Datasheet

FL MC 2000T. Fiber optic converter for 10/100Base-Tx to single- or multi-mode fiberglass with SC-duplex and ST connections. Data sheet 3379_en_B

MODEL: GR8-EM. Communication Adaptor GR8 Series

FL MC 2000E (SM40) LC

CODESYS 3 Programmable Gateway for the BL67 I/O System Multiprotocol Ethernet gateway for PROFINET, EtherNet/IP and Modbus TCP BL67-PG-EN-V3

Industrial PoE Media Converter

Intelligent 4 Port RS-422/485 to 2 Port Ethernet Serial Device Server with PoE

PT2060 Monitor. PT2060/91 SIM System Interface Module. Specifications. Electrical. Messtechnik

DTM Distributed Transmitter Monitor

Industrial Ethernet Switch

ECAN-240. (Modbus TCP to 2-port CAN Bus Gateway User manual) ECAN-240 Modbus TCP to 2-port CAN Bus Gateway User Manual, Version 1.0.

ETHERNET/MFC 010 Supplementary instructions

EE360. High-End Moisture in Oil Transmitter. Typical applications. Features EE360 EE360. (+34)

CODESYS 3 Programmable Gateway for the BL20 I/O System Multiprotocol Ethernet Gateway for PROFINET, EtherNet/IP and Modbus TCP BL20-PG-EN-V3

Industrial Ethernet Switch. Signamax Connectivity Systems. Industrial Ethernet Switch. Model A Series. User s Guide

PROFIBUS-DP/MODBUS RTU REPEATER

ROCKETLINX ES8508 ES8508 ES8508F ES8508-XT ES8508F-XT QUICK INSTALLATION GUIDE

AI561 Analog Input Module

Bulletin 290/291 ArmorStart LT Distributed Motor Controllers Specifications

NGC-40-BRIDGE. Control and Monitoring Modules for use with the nvent Raychem NGC-40 System Installation Instructions

MODEL CIO-EN MODBUS/TCP, MODBUS/RTU I/O MODULE

MGate 5105-MB-EIP Quick Installation Guide

MESR Port Industrial Modbus Gateway. Specifications Power. MESR424_r000_2913ds

Industrial 2-port RS422/485 Modbus Gateway

Power Input Assignment Power1 12VDC DC Jack VDC Power2 - Power Ground

MGate 5111 Quick Installation Guide

COMTRAXX COM460IP. BMS-Ethernet-Gateway

AO561 Analog Output Module

CuteLine AIN8 UI - Voltage Current. Manual

Support 1 RS-232 or RS-485/422 serial port to 1 10/100Base-T(X) self-adaptive Ethernet interface

MGate 5118 Quick Installation Guide

Installation- and Operating instructions for CU Ethernet Controller with USB Input. Version: 1.4 Date:

CU USB-Extender-Rx (USB and DVI Extender) Version: 0.3 Date:

Industrial 1-port RS422/485 Modbus Gateway

Power Serial Device Server

8 Channel Analog Input Module Datasheet. Address / Baud rate / range configurable by the user

GW-7472 / GW EtherNet/IP to Modbus RTU/TCP Gateway User Manual

Operating Manual UMB ISO Converter ISOCON Order Number: 8160.UISO

Carbon Monoxide Sensor - ModBus

QUICK SETUP GUIDE PMC-1000, PMC-1001, PMM-1000, PMB PM Series Power Meter. Safety Information. Equipment Maintenance and Service.

Hardened 10/100Base-TX IEEE802.3at PoE PSE Ethernet Extender

D-100 FLOW DISPLAY MODBUS Network Interface Installation Guide

DI572 Digital Input Module

H704-42(H)(E), H704-42/1(H)(E)

Hardened PoE Ethernet Switch

Legacy Serial. Legacy Serial Redundant Ring Ethernet Extender DDW-222. High Speed Ethernet extension over copper. Configuration and diagnostics

Installation and Setup

8-Port 10/100BASE-TX Hardened Ethernet Extender Switch

BMS-Ethernet-Gateway COM460IP

SK CU4-PBR-C Part number:

MGate 5105-MB-EIP Series

Soft Starter Remote Operator. Section 1.0 Introduction 1.1 Important user information General Manual description...2.

DI561 Digital Input Module

8~14-Port Managed Ethernet Switch

Quick Start Guide. Installation. User s Manual 1

PCAN-Repeater DR CAN Repeater for the Decoupling of Bus Segments. User Manual. Document version ( )

Data sheet GCM MOD GMM EC.1 Communications module Modbus for GMM EC

COMTRAXX COM465DP. Condition Monitor with integrated gateway for the connection of Bender devices to PROFIBUS DP and Ethernet TCP/IP networks

C-DIAS EtherNet/IP Slave CIP 022

SDM-6RO. Expansion Module 6 relay outputs. Manufactured for

Extruder Controls ExtruVision S

Micro Motion Model 7950 and Model 7951 Signal Converters

Power Input Assignment Power1 12VDC DC Jack VDC Power2 - Power Ground

CODESYS 3 Programmable Gateway for the BL20 I/O System Multiprotocol Ethernet Gateway for PROFINET, EtherNet/IP and Modbus TCP BL20-PG-EN-V3

MICROFUSION FEATURES OPTIONS CERTIFICATIONS (PENDING) THREE PHASE SCR POWER CONTROLLERS

Managed 100 Mbps Ethernet Switches TOP FRONT. Click 340/341/342

User Manual Entry Line Industrial Fast Ethernet Switch 5x 10/100Base-TX

INDUSTRIAL POE SWITCH

NGC-40-BRIDGE CONTROL AND MONITORING MODULES FOR USE WITH THE RAYCHEM NGC-40 SYSTEM INSTALLATION INSTRUCTIONS

ICPDAS FSM-510G Series Ethernet Management Switch Quick Start

Installation and Configuration Guide

DKG-210 UNIVERSAL INTERNET GATEWAY UNIT

SK TU4-PBR Part number:

R70 Ethernet to CAN interface Manual (1.4 EN)

PM Series Power Meter

EX-RC1 Remote I/O Adapter

Industrial Serial Device Server

Hardened Web-Smart PoE & High Power PoE Ethernet Switch

DC561, digital input/output module,

EX-RC1 Remote I/O Adapter

ISOMETER isoev425 with coupling device AGH420

MIC-2 Multi-instrument DATA SHEET

UR51 Industrial Cellular Router

MESR9xx. Vlinx Industrial MODBUS Ethernet to Serial Gateway B&B ELECTRONICS PRODUCT INFORMATION

ies8g COMMUNICATIONS Features Intelligent 8 Port Managed Gigabit Ethernet Switch Tel: Fax:

ISOMETER isoev425/isoev425hc with coupling device AGH420

RS485 MODBUS Module 6RO

BAS Router BACnet Multi-Network Router

MODEL: R3-NE1. Remote I/O R3 Series. ETHERNET INTERFACE MODULE (Modbus/TCP) 27.5 (1.08)

CANopen IO X2 Fact sheet

XPSMF40. Main. Safety module name. Monitoring safety detection discrete input Monitoring safety dialogue discrete output

Hardened Ethernet Switch. Signamax Connectivity Systems. Hardened Ethernet Switch. Model G Series. User s Guide

Three-phase electricity meter with instantaneous reading of electrical variables. Input current measurement: 5 A, 90 A, 150 A, 250 A (span by model).

Transcription:

ETHERNET/MFC 010 Technical Datasheet EtherNet/IP interface box in combination with MFC 010 Seamless integration into EtherNet/IP environments Integrated web server for easy configuration, maintenance and diagnostics 2-port Ethernet switch enabling flexible network topologies KROHNE

CONTENTS ETHERNET/MFC 010 1 Product features 3 1.1 Seamless EtherNet/IP integration for Coriolis mass flowmeters... 3 1.2 Features... 4 1.3 Communication with the field device... 4 1.4 Connections... 5 1.4.1 Class 1... 5 1.4.2 Class 3... 5 2 Technical data 6 2.1 Technical data... 6 2.2 Field device connector... 7 2.3 Power connector... 7 2.4 Ethernet connectors... 7 3 Installation 8 3.1 Mounting the EtherNet/IP interface box... 8 4 Notes 9 2

ETHERNET/MFC 010 PRODUCT FEATURES 1 1.1 Seamless EtherNet/IP integration for Coriolis mass flowmeters The EtherNet/IP TM interface box is used to provide a seamless connection between a mass flowmeter and an EtherNet/IP TM network. The EtherNet/IP TM interface box enables the scanner of the EtherNet/IP TM network to control the field device. No proprietary configuration software is needed. All necessary configuration can be made via the built-in web interface or engineering tool using the EDS. EtherNet/IP TM is many times faster than most other established protocols used in process automation today. This allows unequalled fast exchange of process data and virtually instantaneous configuration of the field device. Highlights Integrated switch for line and ring topology Support of Device Level Ring (DLR) for redundancy Password protected web server to facilitate configuration and diagnosis of the device Electronic Data Sheet (EDS) available for convenient deployment Add-On Instruction (AOI) available for use in Rockwell environments Industries Food & Beverage 1 Power connector This connector is used to apply power to the EtherNet/IP TM interface box. It is also used to connect protective earth (PE) to the power connector. 2 USB port This port is intended for authorised service personel use only. 3 Factory reset button This button can be used to perform a reset to factory settings. 4 Status LEDs 5 EtherNet/IP TM connectors 2-port switch with daisy chain functionality. 6 Modbus RTU connector 7 DIN rail connector The DIN rail mechanism fastens the EtherNet/IP TM interface box to a DIN rail and connects it to the protective earth (PE). 3

1 PRODUCT FEATURES ETHERNET/MFC 010 1.2 Features The EtherNet/IP TM interface box supports the following features: 2 EtherNet/IP TM ports with - Support for Beacon-based DLR and linear network topology - Galvanically isolated bus electronics - 10/100 Mbit, full/half duplex operation Choice of two pre-defined sets of input data Modbus RTU port with configurable termination and polarisation Web server with field device specific user interface - Status information - Access to all parameters of the flowmeter - Calibration procedures - Settings page - Diagnostic information 1.3 Communication with the field device The EtherNet/IP TM interface box communicates via Modbus RTU Protocol with the attached field device. The following parameters can be configured: Modbus slave address of the field device Baud rate Parity Termination and polarization Write timeout Disconnect time After power up, the EtherNet/IP TM interface box tries to connect with the field device until the connection can be established. As long as no connection is established LED FD is flashing green. If a compatible field device is connected, LED FD will switch to green. Otherwise LED FD will be flashing red. The EtherNet/IP TM interface box can be used with the following field devices: OPTIMASS 1010 C OPTIMASS 3010 C OPTIMASS 7010 C OPTIGAS If the connection is disturbed or interrupted longer than the specified disconnect time, the EtherNet/IP TM interface box will shut down the connection and try to reconnect. When the baud rate, the parity or the Modbus slave address is changed and a device is connected, the change will be performed in the field device. Afterwards the connection will be re-established with the changed parameters. 4

ETHERNET/MFC 010 PRODUCT FEATURES 1 1.4 Connections 1.4.1 Class 1 General details Class 1 connections are used to transfer I/O data and can be established to instances in the assembly object. Each class 1 connection will establish two data transports - one consuming and one producing. The heartbeat instances can be used for connections that shall only access inputs. Class 1 connections use UDP transport. Total number of supported class 1 connections: 4 Supported API: 2...3200 ms T O connection type: Point-to-point, Multicast O T connection type: Point-to-point Supported trigger types: Cyclic, CoS Connection types Exclusive-Owner connections Process values without configuration Process values with configuration Extended process values without configuration Extended process values with configuration Input-Only connections Input Only Input Only Ext Listen-Only connections Listen Only Listen Only Ext 1.4.2 Class 3 The EtherNet/IP TM interface also supports class 3 connections. General details Class 3 connections are used to establish connections towards the message router. Thereafter, the connection is used for explicit messaging. Class 3 connections use TCP transport. No. of simultaneous class 3 connections: 16 Supported API: 2...10000 ms T O Connection type: Point-to-point O T Connection type: Point-to-point Supported trigger type: Application 5

2 TECHNICAL DATA ETHERNET/MFC 010 2.1 Technical data Measuring system Description Network settings Operating conditions Temperature Relative humidity Installation conditions Mounting Dimensions Weight The EtherNet/IP TM interface box is used to provide a seamless connection between a mass flowmeter and an EtherNet/IP TM network. The EtherNet/IP TM interface box enables the scanner of the EtherNet/IP TM network to control the field device. No proprietary configuration software is needed. All necessary configuration can be made via the built-in web interface or engineering tool using the EDS. DHCP: On Hostname: <none> Port 1 Ethernet link speed: Auto Port 2 Ethernet link speed: Auto Operating temperature: -20...+70 C / -4...+158 F Storage temperature: -20...+85 C / -4...+185 F The product is designed for a relative humidity of 5% to 95% non-condensing. The EtherNet/IP TM interface box can be physically installed by mounting it onto a DIN rail. L x w x h [mm]: 101 x 35 x 109.8 (without connector); L x w x h [inch]: 4 x 1.4 x 4.3 (without connector) 144 g / 0.3 lb (with connector) Electrical connection Supply voltage The EtherNet/IP TM interface box requires a 24 V (-60%/+25%) DC power source. Power consumption The typical power consumption is 150 ma at 24 V. Protective earth (PE) requirements In order to achieve proper EMC behaviour, the product must be connected to protective earth (PE) via the DIN rail connector. If the DIN rail cannot be used, PE must be connected to the power connector. We cannot guarantee proper EMC behaviour unless these PE requirements are fulfilled. Note: According to the EtherNet/IP TM specification, the shield of each RJ-45 connector is not directly connected to PE. There shall however be a low impedance connection of infrastructure components, such as patch panels, to PE. 6

ETHERNET/MFC 010 TECHNICAL DATA 2 2.2 Field device connector The connector used to connect to the field device is located at the bottom of the EtherNet/IP TM interface box. Terminal Description PE PE/shield A RS-485 A line (+) B RS-485 B line (-) GND RS-485 signal ground Proper grounding is mandatory for reliable operation of the device. Shield and signal ground shall not be interconnected. 2.3 Power connector Terminal Description + +24 VDC - Supply ground Earth symbol PE (protective earth) MFC 010 power supply with 12 VDC is needed! The terminal tightening torque must be between 0.5...0.8 Nm / 5...7 lbs-in. 2.4 Ethernet connectors The two standard Ethernet connectors (RJ45) are marked as "X1" and are located on the front of the EtherNet/IP TM interface box. Properly shielded cables shall be used for reliable operation of the device. LED Description 1 Not connected 2 Not connected 3 Link/Activity LED (port 1) 4 Link/Activity LED (port 2) 7

3 INSTALLATION ETHERNET/MFC 010 3.1 Mounting the EtherNet/IP interface box The EtherNet/IP TM interface box can be physically installed by mounting it onto a DIN rail. DIN rail mounting Make sure the DIN rail fastening mechanism on the back of the module is in a fixed and closed position, i.e. pushed all the way up. To mount the module, first hook it on to the DIN rail (1), then push it against the DIN rail to make it snap on (2). DIN rail unmounting To unmount the module, a screwdriver is needed. Use the screwdriver to push the fastening bracket on the back of the module down until it locks in a fixed and open position (1). Then unhook the module from the DIN rail (2 Fixed and closed position Do not leave the module with the DIN rail fastening mechanism in a fixed and open position. This may eventually wear the fastening mechanism out so it cannot be used efficiently. Be sure to push the DIN rail fastening mechanism back into the fixed and closed position after unmounting the module. 8

ETHERNET/MFC 010 NOTES 4 9

4 NOTES ETHERNET/MFC 010 10

ETHERNET/MFC 010 NOTES 4 11

K K K KROHNE product overview KROHNE - Subject to change without notice. Electromagnetic flowmeters Variable area flowmeters Ultrasonic flowmeters Mass flowmeters Vortex flowmeters Flow controllers Level meters Temperature assemblies Pressure transmitters Analysis products Products and systems for the oil & gas industry Measuring systems for the marine industry Head Office KROHNE Messtechnik GmbH Ludwig-Krohne-Str. 5 47058 Duisburg (Germany) Tel.:+49 203 301 0 Fax:+49 203 301 103 89 info@krohne.com The current list of all KROHNE contacts and addresses can be found at: