Signamax Connectivity Systems

Similar documents
Industrial Ethernet Switch

Hardened PoE Ethernet Switch

Industrial Ethernet Switch. Signamax Connectivity Systems. Industrial Ethernet Switch. Model A Series. User s Guide

XPress-Pro SW User Guide

IES User Manual. 8 FE + 1 MM SC Unmanaged Switch -40 to 75, DIN-rail. v

Hardened Media Converter

Hardened Ethernet Switch. Signamax Connectivity Systems. Hardened Ethernet Switch. Model G Series. User s Guide

IES User Manual. 6 GE + 2 SFP Unmanaged Switch -20 to 60C, DIN-rail. v

XPress-Pro SW User Guide

Industrial PoE Media Converter

Power Input Assignment Power1 12VDC DC Jack VDC Power2 - Power Ground

Quick Start Guide. Physical Description.

Quick Start Guide. Physical Description. The Port Status LEDs

Power Input Assignment Power1 12VDC DC Jack VDC Power2 - Power Ground

Hardened Web-Smart PoE & High Power PoE Ethernet Switch

Hardened 10/100Base-TX IEEE802.3at PoE PSE Ethernet Extender

Quick Start Guide. Installation. User s Manual 1

10/100Base-TX Industrial Ethernet Extender

Hardened Web-Smart High Power PoE Ethernet Switch

10/100Base-TX Industrial Ethernet Extender

Signamax Connectivity Systems Industrial Ethernet Extender. User s Guide

Product names mentioned in this manual may be trademarks or registered trademarks of those products.

Signamax Connectivity Systems FO Series 12-Port Media Converter

5 Port Industrial Ethernet Switch. IES5100 Instruction Manual

Express Ethernet Switch: LB8422A-US LB8421A-US LB8424A-US

Table of Contents... 1 Packing List... 2 FCC Statement... 2 Introduction Product Features... 3 Front Panel... 3 LEDs Installation...

Product names mentioned in this manual may be trademarks or registered trademarks of those products and are hereby acknowledged.

Preface. Media Converter

Manual. Preface. XSNet 3100MC

A valid network connection established. Transmitting or receiving data. ACT stands for ACTIVITY.

Gigabit Ethernet Media Converter

Signamax Connectivity Systems Dual Rate SFP Converter Series U S E R S

ClearCube F6151 Media Converter Chassis System with 10/100BaseTX to 100BaseFX Converter

Signamax Connectivity Systems Gigabit Ethernet SFP Media Converter

EL1142 Series. IEC / IEEE 1613 Hardened 2-Port 10/100BASE-TX to 2-Port 100BASE-FX Media Converter. User s Guide

IEC-0101FT Industrial 10/100TX to 100M-FX Slim Type Converter User Manual

Quick Start Guide. Installation. Physical Description.

EIS-EXTEND-C-EU. Ethernet Coaxial Extender for 10/100 Networks. Extend Ethernet Coaxial Connections Up to 8530 Feet

5-Port Hardened Industrial Gigabit DIN-Rail Switch

10/100/1000T to Mini-GBIC Industrial Switch Converter 10/100/1000T to 1000SX/LX Industrial Switch Converter. AMG9011G-H (-40 to 75C) User Manual

XPress-Pro SW Series Hardened Ethernet Switches Enabling Communication for the Demanding Industrial Environment

The Gigabit Ethernet Media Converter fully complies with IEEE802.3ab 1000Base- T and IEEE802.3z 1000Base-SX/LX Gigabit Ethernet standards.

Installation and Operation Manual

IEC-4001/4002/4301. Quick Installation Guide. Industrial mini Media Converter 10/100Base-TX to 100Base-FX. v

FCC Statement. Trademarks. Preface. Gigabit Ethernet Media Converter

Signamax Connectivity Systems Industrial 10/100BASE-TX Ethernet Extender

Gigabit Ethernet Media Converter

4-port 10/100TX + 1 or 2-port 100FX Industrial Switch. User Manual

PTC-101-M12 Hardware Installation Guide

Industrial 3-Port Fast Ethernet Media Converter Switches

Features and Benefits. Certifications

LNP-0602 series. 6-port Industrial PoE+ Unmanaged Ethernet Switches 4*10/100Tx (30W/Port) + 2*100Fx. User Manual

8-port 10/100Base-TX Switch (INS-806) User s Guide

8 to 14 ports 10/100Base-TX with up to 2-port 100Base-FX or Gigabit Hardened Managed Ethernet Switches. Overview

Hardened 4-Port 10/100/1000M DIN-Rail Mount Switch GATB. User's Manual (V1.0 Version)

LNP series. 5-port Industrial PoE+ Unmanaged Ethernet Switches 4*10/100Tx (30W/Port) + 1*10/100Tx, 12~36VDC Input.

Rugged Industrial Media Converter

10/100TX to 100FX w/ 1 PoE Injector Industrial Media Converter User Manual

Industrial 8-Port 10/100/1000T + 2-Port 100/1000X SFP Ethernet Switch (-40~75 degrees C)

8-port 10/100TX + 2-Port 10/100/1000T/100/1000 SFP Combo with 8 PoE Injectors Industrial Ethernet Switch User Manual

Industrial Slim Type Fast Ethernet Rail Switch

IMC-21 Quick Installation Guide

Rugged MediaConverter

PTC-101 Quick Installation Guide

305FX-N. Phone: Fax: Web:

Moxa Industrial Media Converter PTC-101-M12 Hardware Installation Guide

Industrial 10/100/1000BASE-T to 100/1000BASE-X SFP Media Converter

1 10/100TX FX w/ 1 PoE Injector Industrial Switch. User Manual

8-Port 10/100BASE-TX Hardened Ethernet Extender Switch

Features and Benefits. Certifications

Stride Industrial Ethernet Switches

IMC-101 Series Quick Installation Guide

MOXA EtherDevice Switch EDS-205 Hardware Installation Guide

EDS-G205A-4PoE Hardware Installation Guide

Quick Start Guide. Physical Description. Gigabit Ethernet Media Converter. User s Manual 1. Product Overview. DIP Switch

8 10/100/1000T Industrial Switch. User Manual MS655208(X)

10/100BASE-TX to 100BASE-FX Media Converter. User s Guide. Rev. 01 (JUN. 2002) 1907M110MM16003 RECYCLABLE

6 10/100/1000TX + 2G Fiber Industrial Ethernet Switch User Manual

4TX + 1MMFX Unmanaged Ethernet Switch

IMC-21A Quick Installation Guide

10 Industrial Media Converters

M727xS 10/100BaseTX-FX Selectable Media Converter Installation Guide

RuggedMC RMC40 RUGGEDCOM ISO 9001 REGISTERED. Features and Benefits. 4-Port Ethernet Media and Speed Converter

Korenix JetNet 3000 Series Industrial Entry-Level Ethernet Rail Switch User s Manual

4 10/100/1000T Mini-GBIC with 4 IEEE 802.3at High Power PoE Industrial Wide Temperature Switch. User Manual SISTP LRT

Lantech. IPES /100TX with 4 PoE Injectors 24~48VDC Industrial Switch. User Manual

8-Port IP40 IEEE802.3af PoE Unmanaged Industrial Switch User s Manual

INDUSTRIAL 1000BASE-T TO 1000BASE-X MEDIA CONVERTERS. KCD-400 Series. Installation Guide

KSD-800 Series. Installation Guide. Industrial 8-Port Fast Ethernet Switches with Fiber Connectivity DOC A -1-

114FX6. Phone: Fax: Web: -

MOXA Industrial Media Converter

Industrial 5-Port Fast Ethernet Switches with SFP Slot and optional 4 PoE PSE Ports. Basic Model: KSD-541 PoE Model: KSD-541-P. Installation Guide

Industrial 10G/5G/2.5G/1G/100M Copper to 10GBASE-X SFP+ Media Converter

Industrial Serial RS-232 to Fiber Converter. KSC-200 Series. Installation Guide

5-Port Industrial Ethernet Switch - DIN Rail Mountable

Industrial Unmanaged Ethernet Switch

Lantech. IPGS-0204DSFP 4 10/100/1000T PoE at/af + 2 Dual Speed SFP Industrial Unmanaged Switch

MOXA EtherDevice Switch

ADAM-6541 Series. Ethernet to FiberOptic Converters. Features. Introduction. Specifications. Ordering Information

5/8-Port Industrial Fast Ethernet Switch ISW-500/ISW-800. User's Manual

Transcription:

Signamax Connectivity Systems Hardened Ethernet Switch Model -065-7405TB 065-7408ATB 065-74091FXSTTB 065-74091FXSCTB U S E R S G U I D E 1

Quick Start Guide Hardened Ethernet Switch This quick start guide describes how to install and use the Signamax hardened Ethernet Switch. This is the switch of choice for harsh environments constrained by space. Physical Description The Terminal Block and Power inputs 2

DC Terminal Block Power Inputs: There are two pairs of power inputs can be used to power up this Switch. Redundant power supplies function is supported. You only need to have one power input connected to run the Switch. The 10/100BaseT/TX and 100BaseFX Connectors 1. The 10/100BaseT/TX Connections The following lists the pinouts of 10/100BaseT/TX ports. Pin Regular Ports Uplink port 1 Input Receive Data + Output Transmit Data + 2 Input Receive Data - Output Transmit Data - 3 Output Transmit Data + Input Receive Data + 4 NC NC 5 NC NC 6 Output Transmit Data - Input Receive Data - 7 NC NC 8 NC NC 2. The 100BaseFX Connections The fiber port pinouts: The Tx (transmit) port of device I is connected to the Rx (receive) port of device II, and the Rx (receive) port of device I to the Tx (transmit) port of device II. 3

The Port Status LEDs 4

Functional Description Meets NEMA TS1/TS2 Environmental requirements such as temperature, shock, and vibration for traffic control equipment. Meets IEC61000-6-2 EMC Generic Standard Immunity for industrial environment. UL1604 Class 1, Division 2 Classified for use in hazardous locations. Support 802.3/802.3u/802.3x. Auto-negotiation: 10/100Mbps, full/half-duplex; Auto MDI/MDIX. 100BaseFX: Multi mode SC or ST type; Single mode SC or ST type; WDM Single mode SC type. Support 2048 MAC addresses. Provides 768K bits memory buffer. Alarms for power and port link failure by relay output. Operating voltage and Max. current consumption: 0.76A @ 12VDC, 0.38A @ 24VDC, 0.19A @ 48VDC. Power consumption: 9.12W Max. Power Supply: Redundant DC Terminal Block power inputs with 100-240VAC external power supply. -40 to 75 (-40 to 167 ) operating temperature range. Tested for functional operation @ -40 to 85 (-40 to 185 ). Supports DIN-Rail or Panel Mounting installation. 5

LED State Indication POWER PWR1 PWR2 (Green) FAULT FAULT (Red) Steady Off Steady Off 10/100BaseT/TX or 100BaseFX LNK/ACT (Green) 100 (Yellow) Steady Flashing Steady Off Hardened Ethernet Switch Switch is properly connected to power and turned on. Switch is not connected to power and is turned off. 1. Power failure occurred. 2. Port failure occurred (when port fault alarm dip switch is enabled). 1. Power failure is not occurred. 2. Port failure is not occurred (when port fault alarm dip switch is enabled). 3. Port fault alarm dip switch is disabled. A valid network connection established. LNK stands for LINK. Transmitting or receiving data. ACT stands for ACTIVITY. Light solid yellow for a port transferring at 100Mbps. The port is transferring at 10Mbps If this LED is dark. Assembly, Startup, and Dismantling Assembly: Place the switch on the DIN rail from above using the slot. Push the front of the switch toward the mounting surface until it audibly snaps into place. Startup: Connect the supply voltage to start up the switch via the terminal block. Dismantling: Pull out the lower edge and then remove the switch from the DIN rail. 6

7 Hardened Ethernet Switch

Preface A member of the growing Signamax family of harsh environment switches, this switch addresses a need for a smaller switch. This switch provides an affordable solution for rugged and outdoor environment, transportation road-side cabinet, industrial floor shop, multitenant dwellings or Fiber To The Home (FTTH) applications. Capable of operating at temperature extremes of -40 C to +75 C, this is the switch of choice for harsh environments constrained by space. Plug-and-Play Solution: The switch is a plug-and-play Fast Ethernet Switch in compact size. It doesn't have any complicated software to set up. This manual describes how to install and use the hardened Ethernet Switch. This switch integrates full wire speed switching technology. This switch brings the answer to complicated hardened networking environments. To get the most out of this manual, you should have an understanding of Ethernet networking concepts. In this manual, you will find: Features on the switch Illustrative LED functions Installation instructions Specifications 8

Table of Contents QUICK START GUIDE... 2 PHYSICAL DESCRIPTION... 2 The Terminal Block and Power inputs... 2 The 10/100BaseT/TX and 100BaseFX Connectors... 3 The Port Status LEDs... 4 FUNCTIONAL DESCRIPTION... 5 ASSEMBLY, STARTUP, AND DISMANTLING... 6 PREFACE... 8 TABLE OF CONTENTS... 9 PRODUCT OVERVIEW... 10 HARDENED ETHERNET SWITCH... 10 PACKAGE CONTENTS... 11 PRODUCT HIGHLIGHTS... 11 Basic Features... 11 FRONT PANEL DISPLAY... 12 PHYSICAL PORTS... 13 INSTALLATION... 14 SELECTING A SITE FOR THE SWITCH... 14 DIN RAIL MOUNTING... 15 CONNECTING TO POWER... 16 Redundant DC Terminal Block Power Inputs... 16 Alarms for Power and Port Failure... 17 CONNECTING TO YOUR NETWORK... 18 Cable Type & Length... 18 Cabling... 19 SPECIFICATIONS... 20 APPENDIX A CONNECTOR PINOUTS... 22 CONTACT INFORMATION... 23 9

Product Overview Hardened Ethernet Switch 10

Package Contents Hardened Ethernet Switch When you unpack the product package, you shall find the items listed below. Please inspect the contents, and report any apparent damage or missing items immediately to your authorized reseller. This Switch User s Manual External power adapter & Power Cord (Optional) Product Highlights Basic Features Meets NEMA TS2 Environmental requirements such as temperature, shock, and vibration for traffic control equipment. Meets IEC61000-6-2 EMC Generic Standard Immunity for industrial environment. UL1604 Class 1, Division 2 Classified for use in hazardous locations. Support 802.3/802.3u/802.3X. Auto-negotiation: 10/100Mbps, Full/half-duplex; Auto MDI/MDIX. Support 2048 MAC addresses. Provides 768K bits memory buffer. Alarms for power and port link failure by relay output. Operating voltage and Max. current consumption: 0.76A @ 12VDC, 0.38A @ 24VDC, 0.19A @ 48VDC. Power consumption: 9.12W Max. Power Supply: Redundant DC Terminal Block power inputs with 100-240VAC external power supply. -40 to 75 (-40 to 167 ) operating temperature range. Tested for functional operation @ -40 to 85 (-40 to 185 ). 11

Supports DIN-Rail or Panel Mounting installation. Front Panel Display 12

Status LEDs LED State Indication POWER PWR1 PWR2 (Green) FAULT FAULT (Red) Steady Off Steady Off Switch is properly connected to power and turned on. Switch is not connected to power and is turned off. 3. Power failure occurred. 4. Port failure occurred (when port fault alarm dip switch is enabled). 3. Power failure is not occurred. 4. Port failure is not occurred (when port fault alarm dip switch is enabled). 3. Port fault alarm dip switch is disabled. 10/100BaseT/TX or 100BaseFX LNK/ACT (Green) Steady Flashing A valid network connection established. LNK stands for LINK. Transmitting or receiving data. ACT stands for ACTIVITY. Light solid yellow for a port transferring at 100Mbps. 100 Steady (Yellow) Off The port is transferring at 10Mbps If this LED is dark. Physical Ports This switch provides: Five 10/100BaseT/TX ports Four 10/100BaseT/TX ports + one 100BaseFX port Four 10/100BaseT/TX ports + two 100BaseFX ports Eight 10/100BaseT/TX ports Eight 10/100BaseT/TX ports + one 100BaseFX port Six 10/100BaseT/TX ports + two 100BaseFX ports Four 10/100BaseT/TX ports + four 100BaseFX ports CONNECTIVITY RJ-45 connectors SC or ST connector on 100BaseFX fiber port 13

Installation This chapter gives step-by-step instructions about how to install the switch: Selecting a Site for the Switch As with any electric device, you should place the switch where it will not be subjected to extreme temperatures, humidity, or electromagnetic interference. Specifically, the site you select should meet the following requirements: - The ambient temperature should be between -40 to 75 degrees Celsius. - The relative humidity should be less than 95 percent, non-condensing. - Surrounding electrical devices should not exceed the electromagnetic field (RFC) standards. - Make sure that the switch receives adequate ventilation. Do not block the ventilation holes on each side of the switch - The power outlet should be within 1.8 meters of the switch. 14

DIN Rail Mounting Fix the DIN rail attachment plate to the back panel of the switch. Installation: Place the switch on the DIN rail from above using the slot. Push the front of the switch toward the mounting surface until it audibly snaps into place. Removal: Pull out the lower edge and then remove the switch from the DIN rail. 15

Connecting to Power Redundant DC Terminal Block Power Inputs There are two pairs of power inputs can be used to power up this device. You only need to have one power input connected to run the switch. Step 1: Connect the DC power cord to the plug-able terminal block on the switch, and then plug it into a standard DC outlet. Step 2: Disconnect the power cord if you want to shut down the switch. 16

Alarms for Power and Port Failure Step 1: There are two pins on the terminal block are used for power failure detection. It provides the normally closed output when the power source is active. Use this as a dry contact application to send a signal for power failure detection. Special note: The relay output is normal open position when there is no power to the switch. Please do not connect any power source to this terminal to prevent the shortage to your power supply. 17

Connecting to Your Network Cable Type & Length It is necessary to follow the cable specifications below when connecting the switch to your network. Use appropriate cables that meet your speed and cabling requirements. Cable Specifications Speed Connector Port Speed Half/Full Duplex 10BaseT RJ-45 10/20 Mbps 100BaseTX RJ-45 100/200 Mbps 100BaseFX SC, ST 100/200 Mbps 100BaseFX SC, ST 100/200 Mbps Cable 2-pair UTP/STP Cat. 3, 4, 5 2-pair UTP/STP Cat. 5 MMF (50 or 62.5μm) SMF (9 or 10μm) Max. Distance 100 m 100 m 2 km 15, 40, or 75 km 18

Cabling Step 1: First, ensure the power of the switch and end devices are turned off. <Note> Always ensure that the power is off before any installation. Step 2: Prepare cable with corresponding connectors for each type of port in use. Step 3: Step 4: Step 5: Consult the previous section for cabling requirements based on connectors and speed. Connect one end of the cable to the switch and the other end to a desired device. Once the connections between two end devices are made successfully, turn on the power and the switch is operational. 19

Specifications Hardened Ethernet Switch Applicable Standards Switching Method Forwarding Rate 10BaseT: 100BaseTX/FX: Performance Cable 10BaseT: 100BaseTX: 10/100BaseT/TX auto-negotiating ports with RJ-45 connectors, 100BaseFX fiber ports IEEE 802.3 10BaseT IEEE 802.3u 100BaseTX/FX Store-and-Forward 10 / 20Mbps half / full-duplex 100 / 200Mbps half / full-duplex 14,880pps for 10Mbps 148,810pps for 100Mbps 2-pair UTP/STP Cat. 3, 4, 5 2-pair UTP/STP Cat. 5 Up to 100m (328ft) MMF (50 or 62.5μm), SMF (9 or10μm) 100BaseFX: LED Indicators Per unit Power status (Power 1, Power 2) FAULT Per port 10/100BaseT/TX or 100BaseFX - LNK/ACT (Green), 100 (Yellow) Dimensions Net Weight Power Operating Voltage & Max. Current Consumption Power Consumption 50mm (W) 110mm (D) 135mm (H) (1.97 (W) x 4.33 (D) x 5.31 (H)) 0.8Kg (1.76lbs.) Terminal Block: 12-48VDC 0.76A @ 12VDC, 0.38A @ 24VDC, 0.19A @ 48VDC 9.12W Max. Operating -40 C to 75 (-40 to 167 ) Temperature Tested for functional operation @ -40 to 85 (-40 to 185 ) Storage Temperature -45 C to 85 C (-40 to 185 ) Humidity 5%-95% non-condensing Safety Hazardous location: Class 1, Division 2 group A, B, C & D UL60950-1, EN60950-1, IEC60950-1 EMI FCC Part 15, Class A EN61000-6-3: EN55022, EN61000-3-2, EN61000-3-3 EMS 20

EN61000-6-2: EN61000-4-2 (ESD Standards) EN61000-4-3 (Radiated RFI Standards) EN61000-4-4 (Burst Standards) EN61000-4-5 (Surge Standards) EN61000-4-6 (Induced RFI Standards) EN61000-4-8 (Magnetic Field Standards) EN61000-4-11 (Voltage Dip Standards) Environmental Test Compliance IEC60068-2-6 Fc (Vibration Resistance) IEC60068-2-27 Ea (Shock) IEC60068-2-32 Ed (Free Fall) NEMA TS1/2 Environmental requirements for traffic control equipment 21

Appendix A Connector Pinouts Pin arrangement of RJ-45 connectors: RJ-45 Connector and Cable Pins The following table lists the pinout of 10/100BaseT/TX ports. Pin Regular Ports Uplink port 1 Input Receive Data + Output Transmit Data + 2 Input Receive Data - Output Transmit Data - 3 Output Transmit Data + Input Receive Data + 4 NC NC 5 NC NC 6 Output Transmit Data - Input Receive Data - 7 NC NC 8 NC NC 22

Contact Information SIGNAMAX CONNECTIVITY SYSTEMS An AESP Company 1810 N.E. 144th Street. North Miami, Florida 33181, U.S.A. Phone: 305-944-7710 Fax: 305-652-8489 Sales: 800-446-2377 Tech. Support: 800-446-2377, ext. 201 Http://www.signamax.com E-mail: info@signamax.com 23