User Guide. Westermo Teleindustri AB 2004 REV.A SDW Industrial Ethernet 5-port Switch.

Similar documents
INSTALLATIONSANVISNING INSTALLATION MANUAL INSTALLATIONS ANLEITUNG MANUEL D INSTALLATION RD-48 LV/HV. RS-422/485 Repeater Répéteur RS-422/485

User Guide Westermo Teleindustri AB SDW-500. Industrial Ethernet 5-port Switch.

800xA Networks. NE801 User Manual. Power and productivity for a better worldtm

User Guide. Westermo Teleindustri AB TD-29 DC. FSK-modem Multidrop 2-wire.

User Guide. Westermo Teleindustri AB RV-07B. 19 rack system PS-20 Power card.

User Guide. Westermo Teleindustri AB DDW-100. Industrial Ethernet SHDSL Extender.

User Guide. Westermo Teleindustri AB MCW-211. Industrial Ethernet Media Converter.

User Guide Westermo Teleindustri AB DDW-100. Industrial Ethernet SHDSL Extender.

ODW-621 Fibre Optic Modem

MCW-211-F1G-T1G. Industrial Ethernet Media Converter.

User Guide. Westermo Teleindustri AB 2006 EDW Serial Adapter.

User Guide. Westermo Teleindustri AB DDW-120. Industrial Ethernet SHDSL Extender.

User Guide. Westermo Teleindustri AB Lynx L110 / L210. WeOS. Industrial Ethernet 10-port Switch.

ODW-622 Fibre Optic Modem

Viper port Ethernet M12 switch. User Guide Westermo Teleindustri AB. X1 X5 X9 X6 X10 X7 X11 SRV 1 X2 X8 X12 DC X4

User Guide. Westermo Teleindustri AB Lynx L110 / L210. WeOS. Industrial Ethernet 10-port Switch.

User Guide. Westermo Teleindustri AB DDW-220 WOLVERINE SERIES DDW-220. Industrial Ethernet SHDSL extender.

User Guide Westermo Teleindustri AB. Lynx SERIES. Industrial Ethernet 8-port Switch.

Lynx. Industrial Ethernet 10-port Switch L110 / L210. User Guide

DDW-002-B1. EN Ethernet Broadband Bridge. User Guide Westermo Teleindustri AB. 10/100 BASE-TX LINK DC1 X1 X1 DC2

ODW-641. Industrial Converter PROFIBUS DP to Fibre Optic Link. Point to Point applications. Fibre Optic Modem. User Guide

ED-10 TCP INSTALLATION MANUAL. Industrial Ethernet adapter Serial Server (TCP) Westermo Teleindustri AB 2001 REV.

User Guide. Westermo Teleindustri AB Lynx DSS. WeOS. Industrial Ethernet Device Server Switch.

User Guide Westermo Teleindustri AB. Lynx SERIES. Industrial Ethernet 8-port Switch.

User Guide. Westermo Teleindustri AB RedFox. Ethernet switch and router approved for railway usage.

INDUSTRIAL 1000BASE-T TO 1000BASE-X MEDIA CONVERTERS. KCD-400 Series. Installation Guide

User Guide. Westermo Teleindustri AB DDW-220. Wolverine series DDW-220. Industrial Ethernet SHDSL extender.

General. 5 and 8 port Fast Ethernet switches. 6 and 8 Port Gigabit Ethernet switches. Switches with fiber uplink

User Guide. Westermo Teleindustri AB Lynx DSS L105-S1/L205-S1. WeOS. Industrial Ethernet 5-port Device Server Switch.

Rugged Industrial Media Converter

User Guide. Westermo Teleindustri AB RedFox Industrial. WeOS. Industrial Routing Switch.

FL MC 2000T. Fiber optic converter for 10/100Base-Tx to single- or multi-mode fiberglass with SC-duplex and ST connections. Data sheet 3379_en_B

1 10/100TX FX w/ 1 PoE Injector Industrial Switch. User Manual

AD-01 M-BUS Adapter. Industrial adapter, M-bus, Repeater, Converter and zone controller.

MF727xS INDUSTRIAL 10/100BASE-TX TO 100BASE-FX MEDIA CONVERTER. Installation Guide

PTC-101 Quick Installation Guide

User Guide Westermo Teleindustri AB TDW-33. DIN-rail Tele V.90 modem.

KSD-800 Series. Installation Guide. Industrial 8-Port Fast Ethernet Switches with Fiber Connectivity DOC A -1-

FL MC 2000E (SM40) LC

IES User Manual. 8 FE + 1 MM SC Unmanaged Switch -40 to 75, DIN-rail. v

User Guide. Westermo Teleindustri AB Lynx DSS L106-S2/L206-S2. WeOS. Industrial Ethernet 6-port Device Server Switch.

Korenix JetNet 3000 Series Industrial Entry-Level Ethernet Rail Switch User s Manual

Industrial 3-Port Fast Ethernet Media Converter Switches

CNSEISK 5, 8 & 16- Port Copper and Fibre Sub Miniature Ethernet 10/100 Switches

Industrial 5-Port Fast Ethernet Switches. with SFP Slot and optional 4 PoE PSE Ports. Basic Model: KSD-541. PoE Model: KSD-541-HP. Installation Guide

User Guide. Westermo Teleindustri AB Lynx DSS L108 / L208-F2G-S2. WeOS. Industrial Ethernet 8-port Device Server Switch.

LNP-0602 series. 6-port Industrial PoE+ Unmanaged Ethernet Switches 4*10/100Tx (30W/Port) + 2*100Fx. User Manual

PTC-101-M12 Hardware Installation Guide

MINI-PS AC/10-15DC/8

Ha-VIS econ 2000 Fast and Full Gigabit Ethernet Basic. Features

10/100/1000T to Mini-GBIC Industrial Switch Converter 10/100/1000T to 1000SX/LX Industrial Switch Converter. AMG9011G-H (-40 to 75C) User Manual

PHOENIX CONTACT - 10/2009

10/100TX to 100FX w/ 1 PoE Injector Industrial Media Converter User Manual

Industrial 5-Port Fast Ethernet Switches with SFP Slot and optional 4 PoE PSE Ports. Basic Model: KSD-541 PoE Model: KSD-541-P. Installation Guide

imc2f Features Industrial IEC Ethernet to Fiber Media Converter Tel: Fax:

10/100BASE-TX TO 100BASE-FX MEDIA CONVERTERS EM4000 EM4001. Installation Guide

Industrial 10/100/1000BASE-T to 100/1000BASE-X SFP Media Converter

RuggedMC RMC40 RUGGEDCOM ISO 9001 REGISTERED. Features and Benefits. 4-Port Ethernet Media and Speed Converter

Industrial 8-Port 10/100/1000T + 2-Port 100/1000X SFP Ethernet Switch (-40~75 degrees C)

IEC-0101FT Industrial 10/100TX to 100M-FX Slim Type Converter User Manual

User Guide. Westermo Teleindustri AB RedFox Industrial. WeOS. Industrial Routing Switch.

ICPDAS FSM-510G Series Ethernet Management Switch Quick Start

Quick Start Guide Elinx ESW100 Series. 5 and 8 port Unmanaged Ethernet Switch

EIDX_M Series INSTALLATION GUIDE INTRODUCTION. A Line of Managed Ethernet Switching Hubs

M727xS 10/100BaseTX-FX Selectable Media Converter Installation Guide

4-port 10/100TX + 1 or 2-port 100FX Industrial Switch. User Manual

4 10/100/1000T Mini-GBIC with 4 IEEE 802.3at High Power PoE Industrial Wide Temperature Switch. User Manual SISTP LRT

Hardened Media Converter

EI Series INSTALLATION GUIDE INTRODUCTION. A Line of Fixed-Port Industrial Ethernet Hubs

User Guide. Westermo Teleindustri AB DDW-226 WOLVERINE SERIES. WeOS. Industrial Ethernet SHDSL extender.

8 10/100/1000T Industrial Switch. User Manual MS655208(X)

Hardened PoE Ethernet Switch

10/100BASE-TX TO 100BASE-FX MEDIA CONVERTERS. KC-300DM Series. Installation Guide

Industrial PoE Media Converter

MC 11 EB-2 Power supply cabinet with external bus, AC version

Quick Start Guide. Installation. User s Manual 1

FL SWITCH SFNB. Five- and Eight-Port Standard Function Ethernet Switch with Narrow Housing. AUTOMATION Data Sheet 2642_en_H.

Rugged MediaConverter

TN-5308 Quick Installation Guide

Industrial 8-Port 10/100TX Compact Ethernet Switch

8-port 10/100TX + 2-Port 10/100/1000T/100/1000 SFP Combo with 8 PoE Injectors Industrial Ethernet Switch User Manual

Lantech. IPES /100TX with 4 PoE Injectors 24~48VDC Industrial Switch. User Manual

Quick Start Guide. Physical Description. The Port Status LEDs

User Manual. MS657140X Industrial Fast Ethernet Switch 8x 10/100Base-TX

Legacy Serial. Legacy Serial Redundant Ring Ethernet Extender DDW-222. High Speed Ethernet extension over copper. Configuration and diagnostics

Lantech IPGC-0101DSFP. User Manual. 10/100/1000T (PoE at) to 100/1000M SFP Industrial Switch Converter

Industrial Ethernet Switch

PoE Powered 10/100BASE-TX to 100BASE-FX Media Converters. KC-351 Series. Installation Guide

KFC-200. Installation Guide

IMC-21GA Quick Installation Guide

ED-12 TCP INSTALLATION MANUAL. Industrial Ethernet adapter Dual serial channels Westermo Teleindustri AB 2003 REV.

Power Input Assignment Power1 12VDC DC Jack VDC Power2 - Power Ground

PHOENIX CONTACT - 07/2006

Ha-VIS mcon 3000 Next Generation Introduction and features

MC-4TX Series Industrial 4 Port Ethernet to Media Converter. Industrial 4 Port Ethernet to Fiber Media Converter. Part of GE Security

FSM-510G Series Ethernet Management Switch Quick Start Guide

LNP series. 5-port Industrial PoE+ Unmanaged Ethernet Switches 4*10/100Tx (30W/Port) + 1*10/100Tx, 12~36VDC Input.

imc2 Features Introduction Industrial 2 Port Ethernet to Fiber Converter Tel: Fax:

User Guide Westermo Teleindustri AB EDW-100. Serial Adapter.

Industrial 10G/5G/2.5G/1G/100M Copper to 10GBASE-X SFP+ Media Converter

Transcription:

User Guide SDW-500 S E R I E S 6644-2211 Westermo Teleindustri AB 2004 REV.A Industrial Ethernet 5-port Switch www.westermo.com

Contents 1. Description... 3 2. Safety... 4 3. Approvals... 4 3.1 Declaration of Conformity... 5 4. Specification... 6 7 5. Maintenance... 8 6. Installation... 8 6.1 Mounting / Removal... 8 6.2 Connections... 9 6.2.1 Power... 10 6.2.2 TX... 10 6.2.3 FX SC Multi- or single mode (optional)... 10 6.2.4 FX ST Multi mode (optional)... 10 6.2.5 FX LC Single mode (optional)... 10 6.3 DIP switch settings SDW-550... 11 12 6.4 DIP switch settings SDW-541 and SDW-532... 13 14 6.5 LED indicators... 15 2 6644-2211

1. Description The SDW-500 is a series of Industrial Ethernet 5-port switches. Several variations are available ranging from a version with five RJ-45 TX (copper) ports to versions having two FX (fibre) and three TX ports. All TX ports support auto-negotiation, but DIP-switches also allow speed and duplex configuration of any individual TX port. It is also possible to set up one port to monitor traffic to/from the switch. The SDW-500 series has been designed to meet high industrial specifications, providing very high dependability in harsh environmental conditions. Features: Flexible mix of TX (copper) and FX (fibre) interface TX shields individually isolated Wide DC power range 12 48 VDC Wide temperature range Redundant power Automatic MDI/MDI-X crossover LED indicators for Power, Speed, Duplex, Link and Traffic Port monitoring 35 mm DIN rail mounting SC, ST and LC fibre interface Multi (MM) and single mode (SM) fibre Example of applications are: 5-port switch Fibre to copper converter Ethernet isolator, for STP network 6644-2211 3

2. Safety! General: Before using this unit, read this manual completely and gather all information on the unit. Make sure that you understand it fully. Check that your application does not exceed the safe operating specifications for this unit.!! Before installation, maintenance or modification work: Prevent damage to internal electronics from electrostatic discharges (ESD) by discharging your body to a grounding point (e.g. use of wrist strap). Prevent access to hazardous voltages by disconnecting the unit from AC/DC mains supply and all other electrical connections. Installation: This unit should only be installed by qualified personnel. This unit should only be installed in a restricted access area, for example a lockable cabinet where access is restricted to service personnel only. This unit is intended for permanent connection to the AC/DC mains supply. The power supply wiring must be sufficiently fused, and if necessary it must be possible to disconnect manually from the AC/DC mains supply. Ensure compliance to national installation regulations. Units with the rated voltage exceeding 42.4 V peak or 60 VDC, are defined as class I equipment with a protective earthing conductor terminal. Units with the rated voltage up to 42.4 V peak or 60 VDC, are defined as class III equipment and shall be separated from hazardous voltage by double or reinforced isolation. This unit uses convection cooling.to avoid obstructing the air flow around the unit, follow the spacing recommendations (see Installation section). 3. Approvals Conformity with the Directive 73/23/EEC Low Voltage Directive LVD has been assessed by application of the standard EN 60 950. Conformity with the Directive 89/336/EEC Electromagnetic Compatibility (EMC) has been assessed by application of standards EN 61000-6-2 (industrial immunity) and EN 61000-6-3 (residential emission) and EN61000-6-4 (Industrial emission). 4 6644-2211

3.1 Declaration of Conformity Westermo Teleindustri AB Declaration of conformity The manufacturer Westermo Teleindustri AB SE-640 40 Stora Sundby, Sweden Herewith declares that the product(s) Type of product Model Art no Installation manual DIN-rail SDW-550 LV 3644-0010 6644-2211 DIN-rail SDW-532-MM-SC2-SM-SC15 LV 3644-0019 6644-2211 DIN-rail SDW-541-MM-SC2 LV 3644-0020 6644-2211 DIN-rail SDW-541-MM-ST2 LV 3644-0021 6644-2211 DIN-rail SDW-541-SM-LC15 LV 3644-0022 6644-2211 DIN-rail SDW-541-SM-SC15 LV 3644-0024 6644-2211 DIN-rail SDW-532-2MM-SC2 LV 3644-0030 6644-2211 DIN-rail SDW-532-2MM-ST2 LV 3644-0031 6644-2211 DIN-rail SDW-532-2SM-LC15 LV 3644-0032 6644-2211 DIN-rail SDW-532-2SM-SC15 LV3644-0034 6644-2211 is in conformity with the following EC directive(s). No Short name 89/336/EEG Electromagnetic Compatibility (EMC) References of standards applied for this EC declaration of conformity. No Title Issue EN 61000-6-2 Immunity for industrial environments 2 (2001) EN 61000-6-3 Emission standard for residential, commercial and 1 (2001) light-industrial environments (3644-0010) EN 61000-6-4 Emission standard for industrial environments (3644-0020 and 3644-0030) 1 (2001) The last two digits of the year in which the CE marking was affixed: 04 Hans Levin Technical Manager 15th December2004 Org.nr/ Postadress/Postal address Tel. Telefax Postgiro Bankgiro Corp. identity number Registered office S-640 40 Stora Sundby 016-428000 016-428001 52 72 79-4 5671-5550 556361-2604 Eskilstuna Sweden Int+46 16428000 Int+46 16428001 6644-2211 5

4. Specification Power interface SDW-500 series Rated voltage 12 48 VDC, polarity protected Operating voltage 9.6 57.6 VDC Rated current @12 VDC power input SDW-550 SDW-541-MM-SC2 SDW-541-MM-ST2 SDW-541-SM-LC15 SDW-541-SM-SC15 SDW-532-2MM-SC2 SDW-532-2MM-ST2 SDW-532-2SM-LC15 SDW-532-2SM-SC15 SDW-532-MM-SC2-SM-SC15 Rated frequency DC Connection Detachable screw terminal Connector size 0.2 2.5 mm 2 (AWG 24-12) 320 ma 450 ma 450 ma 350 ma 350 ma 600 ma 600 ma 450 ma 450 ma 450 ma Ethernet TX Interface Electrical specification Data rate Duplex Connection Circuit type Transmission range Ethernet FX Interface Fibre optic specification Data rate Duplex Connection Transmission range Mechanical Dimension (W x H x D) Weight Mounting Degree of protection IEEE std 802.3. 2000 edition 10 Mbit/s or 100 Mbit/s, manual or auto Full or half, manual or auto RJ-45, shielded TNV-1 100 m IEEE std 802.3. 2000 edition, multi or single mode, 1300 nm 100 Mbit/s Full SC, ST, or LC 2 or 15 km 35 x 121 x 119 mm 0.2 kg DIN-rail IP21 6 6644-2211

Isolation between interfaces Power Interface to all other TX signal Interface to all other TX shield Interface to all other Environmental Temperature, operating Temperature, storage and transportation Relative humidity, operating Relative humidity, storage and transportation 2.8 kv DC 2.0 kv RMS @ 50 Hz and 60 s duration 2.1 kv DC 1.5 kv RMS @ 50 Hz and 60 s duration 1.5 kv DC 1.0 kv RMS @ 50 Hz and 60 s duration 25 to +70 C (SDW-550), 25 to +65 C (SDW-541), 25 to +60 C (SDW-532) 25 to +70 C 5 to 95% (non-condensing) 5 to 95% (condensation allowed outside packaging) Configuration Auto configured (auto-negotiation) or manually setting of speed and duplex of individual TX port, by DIP-switches. Port mirror function is possible to set with DIP-switch. With the port mirror function active the switch will copy all outgoing traffic to port 1. This can be used to monitor all traffic going out from the switch. Packets may be discarded if the total throughput exceeds the port speed of port 1. 6644-2211 7

5. Maintenance No maintenance is required, as long as the unit is used as intended within the specified conditions.! 6. Installation 6.1 Mounting / Removal Before mounting or removing the unit: Prevent damage to internal electronics from electrostatic discharges (ESD) by discharging your body to a grounding point (e.g. use of wrist strap). Prevent access to hazardous voltages by disconnecting the unit from AC/DC mains supply and all other electrical connections. Mounting This unit should be mounted on 35 mm DIN-rail which is horizontally mounted on a wall or cabinet backplate. This unit uses convection cooling.to avoid obstructing the airflow around the unit, use the following spacing rules. Recommended spacing 25 mm (1.0 inch) above/below and 10 mm (0.4 inches) left/right the unit. Snap on mounting, see figure 10 mm * (0.4 inches) 25 mm CLICK! * Spacing (left/right) recommended for full operating temperature range 25 mm Removal Press down the black support at the back of the unit, see figure. 8 6644-2211

6.2 Connections LED indicators Network RJ-45 connection Network Fibre connection or RJ-45 connection Power connection Available models: SDW-550 10/100Base-T/TX: 5 ports SDW-541 10/100Base-T/TX: 4 ports 100Base-FX: 1 port SDW-532 10/100Base-T/TX: 3 ports 100Base-FX: 2 ports NOTE! SDW-532-MM-SC2-SM-SC15 Port 4: SC Single mode 15 km connector Port 5: SC Multi mode 2 km connector 6644-2211 9

6.2.1 Power The SDW-500 series supports 3-pos screw terminal Description redundant power connection. 1 COM The positive input are +VA 2 +VA and +VB, the negative input 3 +VB for both supplies are COM. The power is drawn from the input with the highest voltage. 1 2 3 6.2.2 TX Ethernet TX connection (RJ-45 connector), automatic MDI/MDI-X crossover. Contact Signal Name Direction Description/Remark 1 TD+ In/Out Transmitted/Received data 2 TD In/Out Transmitted/Received data 3 RD+ In/Out Transmitted/Received data 4 5 6 RD In/Out Transmitted/Received data 7 8 Shield HF-connected CAT 5 cable is recommended. Unshielded (UTP) or shielded (STP) connector might be used. 8 7 6 5 4 3 2 1 6.2.3 FX SC Multi- or single mode (optional) Ethernet FX connection. 1300 nm multi- or singlemode fibre tranceiver with SC-connector. The dust protection plug shall be mounted when no fibre is connected. 6.2.4. FX ST Multi mode (optional) Ethernet FX connection. 1300 nm multi mode fibre tranceiver with ST-connector. The dust protection plugs shall be mounted when no fibre is connected. 6.2.5. FX LC Single mode (optional) Ethernet FX connection. 1300 nm singlemode fibre transceiver with LC-connector. The dust protection plug shall be mounted when no fibre is connected. 10 6644-2211

6.3 DIP switch settings SDW-550 DIP-switches are accessible under the lid on top of the unit. DIP-switches are used to configure the unit.!! Warning! Prevent damage to internal electronics from electrostatic discharges (ESD) by discharging your body to a grounding point (e.g. use of wrist strap), before the lid on top/front of the unit is removed. Warning! Do not open connected equipment. Prevent access to hazardous voltages by disconnecting the unit from AC/DC mains supply and all other electrical connections. NOTE When configuration via DIP-switches, the settings of DIP-switches configure the unit only after a reboot (power off/on). To be observe when the DIP-switches will be configured Speed and duplex setting only valid when auto-negotiation is disabled. When monitoring selected all outgoing packets from the switch is also copied to the port 1. If auto-negotiation and auto MDI/MDI-X disabled all TX ports support MDI-X configuration. 6644-2211 11

Port 1 settings auto MDI/MDI-X disabled auto MDI/MDI-X enabled Port 4 settings auto MDI/MDI-X disabled auto MDI/MDI-X enabled Port 2 settings auto MDI/MDI-X disabled auto MDI/MDI-X enabled Port 5 settings auto MDI/MDI-X disabled auto MDI/MDI-X enabled Port 3 settings auto MDI/MDI-X disabled auto MDI/MDI-X enabled Port mirroring settings No monitoring selected Monitoring selected Factory settings 12 6644-2211

6.4 DIP switch settings SDW-541 and SDW-532 DIP-switches are accessible under the lid on top of the unit. DIP-switches are used to configure the unit.!! Warning! Prevent damage to internal electronics from electrostatic discharges (ESD) by discharging your body to a grounding point (e.g. use of wrist strap), before the lid on top/front of the unit is removed. Warning! Do not open connected equipment. Prevent access to hazardous voltages by disconnecting the unit from AC/DC mains supply and all other electrical connections. NOTE When configuration via DIP-switches, the settings of DIP-switches configure the unit only after a reboot (power off/on). To be observe when the DIP-switches will be configured Speed and duplex setting only valid when auto-negotiation is disabled. When monitoring selected all outgoing packets from the switch is also copied to the port 1. Speed and duplex switch settings are ignored for FX ports. If auto-negotiation and auto MDI/MDI-X disabled all TX ports support MDI-X configuration. 6644-2211 13

Port 1 settings auto MDI/MDI-X disabled auto MDI/MDI-X enabled Port 4 settings* auto MDI/MDI-X disabled auto MDI/MDI-X enabled Port 2 settings auto MDI/MDI-X disabled auto MDI/MDI-X enabled Port 3 settings auto MDI/MDI-X disabled auto MDI/MDI-X enabled * Setting of port 4 is only possible when using SDW-541. These settings are ignored when using SDW-532 Port mirroring settings No monitoring selected Monitoring selected Factory settings 14 6644-2211

6.5 LED indicators At power on the PWR flashes during initialising. Indicators (LED) Power (PWR) Link (LINK) of every port Speed (SPD) and duplex (DPX) of TX ports LED Status Indication of PWR Internal power, initialising OK Slow flash Initialisation progressing Fast flash Initialisation error LINK OFF No Ethernet link Good Ethernet link Flash Ethernet data is transmitted or received, traffic indication SPD OFF 10 Mbit/s (TX only) 100 Mbit/s DPX OFF Half duplex (TX only) Full duplex

Application example Westermo Teleindustri AB SE-640 40 Stora Sundby, Sweden Phone +46 16 42 80 00 Fax +46 16 42 80 01 E-mail: info@westermo.se Westermo Web site: www.westermo.com Westermo Data Communications Ltd Talisman Business Centre Duncan Road Park Gate, Southampton SO31 7GA Phone: +44(0)1489 580 585 Fax.:+44(0)1489 580586 E-Mail: sales@westermo.co.uk Westermo Data Communications GmbH Goethestraße 67, 68753 Waghäusel Tel.: +49(0)7254-95400-0 Fax.:+49(0)7254-95400-9 E-Mail: info@westermo.de Subsidiaries Westermo Data Communications S.A.R.L. 9 Chemin de Chilly 91160 CHAMPLAN Tél : +33 1 69 10 21 00 Fax : +33 1 69 10 21 01 E-mail : infos@westermo.fr Westermo Teleindustri AB have distributors in several countries, contact us for further information. T04-0330 6644-2210 04.12 Mälartryck AB, Eskilstuna, Sweden