IES618-4D series Industrial Ethernet switch User manual

Similar documents
IES618-4D series Industrial Ethernet switch User manual Shenzhen 3onedata Technology Co.,Ltd

IES615-2D series Industrial Ethernet switch User manual Shenzhen 3onedata Technology Co.,Ltd

IES615-2D Series. Industrial Ethernet Switch. User Manual. Summarize. Panel layout. Packing list. Features. Shenzhen 3onedata Technology Co., Ltd.

Please check the packaging and accessories by your first using. Industrial Ethernet switch ⅹ 1 User manual ⅹ 1

IES7110-2GS Series. Managed Industrial Ethernet Switch. User manual. Summarize. Panel layout. Packing list. Feature

Industrial Ethernet switch ⅹ 1 Documentation and software CD ⅹ 1 User manual ⅹ 1 DIN-Rail mounting kit ⅹ 1 Warranty card ⅹ 1

Please check the packaging and accessories by your first using. Industrial Ethernet switch(ies7110 series) ⅹ 1 User manual ⅹ 1

IES1024 series. Industrial Ethernet switch. User manual

IES608-2F. Introduction. ntroduction: Packing List. ist: Features:

IES308-2F. Introduction: Packing List: Features: 8-port Unmanaged Industrial Ethernet Switch Hardware Installation Guide

IPS7112G-4GS-8GPOE. Industrial PoE Switch User Manual. Summarize. Panel layout. Packing list. Feature

Tel: Fax:

Support 1 RS-232 or RS-485/422 serial port to 1 10/100Base-T(X) self-adaptive Ethernet interface

NP30XT series serial device server

IDS-141A/181A. Industrial 4-port/8-port slim type serial to Ethernet device server. Features. Introduction. DS-Tool

Industrial Managed Ethernet Switch

Hardened 4-Port 10/100/1000M DIN-Rail Mount Switch GATB. User's Manual (V1.0 Version)

1U Rack Mounting 28-port 100M/Gigabit Layer 2 Managed Electricity Industrial Ethernet Switch

1U Rack-mounted or Wall Mounting 12-port 100M/Gigabit Layer 3 Managed Rail Transit Dedicated Industrial Ethernet Switch

Features and Benefits. Certifications

1Industrial Ethernet Switch

Industrial Gigabit Managed Ethernet Switch

Features and Benefits. Certifications

Arm-based DIN-rail industrial computers with 4 serial ports, 2 LAN ports, 8 DI/DO, and VGA. Features and Benefits. Certifications

Features and Benefits. Certifications

ESW500 Series. Industrial Managed Ethernet Switches

DIN-Rail Mounting 6-port 100M/Gigabit Layer 2 Unmanaged Industrial PoE Ethernet Switch

Industrial Slim Type Fast Ethernet Rail Switch

MGate 5105-MB-EIP Series

Spotlight Versatile Connectivity Provides 16-port 10/100BASE-TX/FX/BX/SFP plus 2-port Gigabit-SX/LX/BX/SFP combo

Spotlight Versatile Connectivity Provides flexibility 12 or 8 10/100/1000BaseT(X) ports and BaseSX/LX/BX/SFP ports

EN port managed Ethernet switch with 8x10/100Base-T(X) and 2xGigabit combo ports, SFP socket

EDR-G902/G903 Quick Installation Guide

Spotlight Versatile Connectivity Provides 8-port 10/100BASE-TX/FX/BX/SFP plus 2-port Gigabit-SX/LX/BX/SFP

Spotlight Versatile Connectivity Modularized Ethernet Switch of 24-port 10/100BASE-TX/FX/BX and 4-port Gigabit-TX/SX/LX/BX/SFP

Features and Benefits. Certifications

Features. Preliminary. Industrial IEEE b/g/n with 2x10/100Base-T(X) 1x RS-232/422/485 IoT LTE LPWAN Gateway. Introduction

Industrial Unmanaged Ethernet Switch

Industrial Media Converter

1Industrial Ethernet Switch

6 Port 10/100/1000M Managed Industrial Ethernet Switch OP-S4F2X-M-I. Shenzhen Optostar Optoelectronics Co., Ltd

4-port 10/100TX + 1 or 2-port 100FX Industrial Switch. User Manual

9 Port 10/100/1000M Managed Industrial PoE Switch OP-S6A3X-M-I. Shenzhen Optostar Optoelectronics Co., Ltd (Version 1)

8 10/100/1000T Industrial Switch. User Manual MS655208(X)

TN-4516A-4GTX Series. EN port managed Ethernet switches. Introduction. Specifications. Industry-specific Ethernet Switches

XPress-Pro SW Series Hardened Ethernet Switches Enabling Communication for the Demanding Industrial Environment

Hardened Managed 8 to 14 ports 10/100BASE and 2-port Gigabit Ethernet Switch with SFP options

Intelligent 4 Port RS-422/485 to 2 Port Ethernet Serial Device Server with PoE

Features and Benefits. Certifications

RGS-7168GCP / RGS-7168GCP-E

MGate 5102-PBM-PN Series

System-vision DDM. Network connection. Monitoring and Configuration interface

Features and Benefits. SNMP MIB-II for network management. Certifications

MOXA Industrial Media Converter

PTC-101-M12 Hardware Installation Guide

Designed for Railway application and fully compliant with the requirement of EN50155/EN standard

LNP-0602 series. 6-port Industrial PoE+ Unmanaged Ethernet Switches 4*10/100Tx (30W/Port) + 2*100Fx. User Manual

Industrial 6-port unmanaged Gigabit PoE Ethernet switch with 4x10/100/1000Base-T(X) P.S.E. and

Features and Benefits. Certifications

IMC-21 Quick Installation Guide

Lite L3 Hardened Managed 16-port (8 x PoE) Gigabit Ethernet Switch. 8 X PoE provides 60 watt Ultra PoE ports Power Budget: 240W. 60W PoE.

IEC /IEEE1613 Managed 24-port 10/100BASE and 4-port Gigabit Ethernet Switch with SFP options

NPort IA5000A Series. 1, 2, and 4-port serial device servers for industrial automation. Overview

IEC-0101FT Industrial 10/100TX to 100M-FX Slim Type Converter User Manual

Hardened Managed 10-port 10/100BASE (8 x PoE) and 2-port Gigabit Ethernet Switch SFP

IES-3080/3062 Series. Industrial 8-port managed Ethernet switch. Features. Introduction

MOXA EtherDevice Switch

8 X PoE provides 60 watt Ultra PoE ports Power Budget: 240W

PT-7728 Series. IEC G-port Gigabit modular managed Ethernet switch. Introduction PT-7728

Features and Benefits. Certifications

RGS-7244GP / RGS-7244GP-E

Spotlight Versatile Connectivity Provides flexibility of 24-port 10/100BASE-TX/FX/BX/SFP plus 4-port Gigabit-TX/SX/LX/BX/SFP

RGS-7244GP / RGS-7244GP-E

Arm-based palm-sized industrial computers with 2 serial ports and 2 LAN ports. Features and Benefits. Certifications

Aquam8628/ G Port Layer3/2 Managed EN50155 Industrial Ethernet Switches

EDS-405A-PTP Series Hardware Installation Guide

10/100/1000T to Mini-GBIC Industrial Switch Converter 10/100/1000T to 1000SX/LX Industrial Switch Converter. AMG9011G-H (-40 to 75C) User Manual

1Industrial Ethernet Switch

1Industrial Ethernet Switch

Moxa Industrial Media Converter PTC-101-M12 Hardware Installation Guide

Features and Benefits. Certifications

1Industrial Ethernet Switch

TN-5508A/5516A Series

5600 Series. 8 and 16-port Serial Device Servers. Features. Internet Readiness for up to 16 Serial Devices

SICOM3000A-LITE. 8+2G Port Layer 2 Managed DIN-Rail Switches

IMC-21A Quick Installation Guide

ies8g COMMUNICATIONS Features Intelligent 8 Port Managed Gigabit Ethernet Switch Tel: Fax:

Managed Ethernet Switches

1Industrial Ethernet Switch

Features and Benefits. User-friendly LCD panel for easy installation Adjustable termination and pull high/low resistors.

8x10/100/1000Base-T(X) ports and 12x100/1000Base-X, SFP socket

Industrial 8-port unmanaged Gigabit PoE Ethernet switch with 8x10/100/1000Base-T(X) P.S.E., 24VDC power inputs

IAP-320 series are reliable a/b/g WLAN Access Point with 2 ports LAN. It supports 802.1X and MAC filters for

NPort S8000 Series. Combo switch / serial device servers. Overview. Supports the Full Range of NPort 5000 Series Device Server Functions

PTC-101 Quick Installation Guide

TN-5308 Quick Installation Guide

Features and Benefits. Certifications

8 to 14 ports 10/100Base-TX with up to 2-port 100Base-FX or Gigabit Hardened Managed Ethernet Switches. Overview

NPort 5200 Series. 2-port RS-232/422/485 serial device servers. Specifications. Serial-to-Ethernet Device Servers

EDS-G308 Series Quick Installation Guide

Transcription:

IES618-4D series Industrial Ethernet switch User manual Shenzhen 3onedata Technology Co., Ltd. Tel: +86-755-26702668 Fax: +86-755-26703485 www.3onedata.com Summarize IES618-4D series is a industrial, management, redundant industrial Ethernet switch and integrate 4 port serial device server. It included 1. IES618-4D(RS-232)-P(12/48VDC), Support 8 port 10/100Base T(X) and 4 port RS-232, 2. IES618-4DI(RS-485)-P(12/48VDC), Support 8 port 10/100BaseT(X) and 4 port RS-485/422, 3. IES618-4F-4DI(RS-485)-P(12/48VDC), Support1-4 port is 10/100BaseT(X) Ethernet, 5-8 port is 100BaseFX fiber port and 4 port RS-485/RS-422, 4. IES618-2F-4D(RS-232)-P(12/48VDC), Support1-6 port is 10/100BaseT(X) Ethernet, 7-8 port is 100BaseFX fiber port and 4 port RS-232, 5. IES618-4F-4D(RS-232)-P(12/48VDC), Support1-4 port is 10/100BaseT(X) Ethernet, 5-8 port is 100BaseFX fiber port and 4 port RS-232, 6. IES618-2F-4DI(RS-485)-P(12/48VDC). Support1-6 port is 10/100BaseT(X) Ethernet, 7-8 port is 100BaseFX fiber port and 4 port RS-485/422, it adopted SW-Ring redundant technology (Recovery time<20ms), users can set the redundant easily to increase network reliability, furthermore. It adopted no fan, low power consumption design, IP40, corrugate high strength iron shell, the performance is more steadily. It accorded with CE, FCC standard and Industrial 4 class, DIN rail installation and wide operating temperature (-40~75 ), it can satisfied some kinds of industrial environment, it can provide reliable and quickly solution for your Ethernet device Packing list Please check the packaging and accessories by your first using. Industrial Ethernet switch(ies618-4d series)ⅹ 1 User manual ⅹ 1 CD ⅹ 1 Certificate of quality ⅹ 1 Warranty card ⅹ 1 Please inform us or our distributor if your equipment s have been damaged or lost any accessories, we will try our best to satisfy you. Features IEEE802.3, IEEE802.3u, IEEE 802.3x, IEEE802.1Q, IEEE802.1p, IEEE802.1D, IEEE802.1W Support SW-RingTM redundant network patent technology (Faulty recovery time<20ms) Support IEEE802.1Q VLAN configuration, Control broadcast storm effectively Support 802.1p _QOS Support RSTP Support SNMP Support IGMP snooping, static multicast filter, port trunking and port mirroring Support port bandwidth limited function, optimize bandwidth utilize Support 4 port RS-232/ RS-485/ RS-422 serial device server Support based on socket application access Support Sever, Client, UDP based mode and Sever, UDP advanced mode Support Windows serial driver procedure mode Support TCP, UDP, ARP, ICMP and DHCP protocol Support cross-gateway and cross-router communication Specific serial self-adapt function (Realcom) Support Web, CLI, Telnet management Support 2K MAC address table Support 2 power supply input and 1 relay alarm output Support port line and redundant network faulty/unusual, local and remote alarm High strength iron shell, IP40 protection Industrial 4 class design Redundant 24VDC power supply input(12~48vdc)

-40~75 working temperature DIN-rail, wall mounting installation Panel Layout IES618-4D series IES618-4DI(RS-485)-P(12/48VDC) 7. RS-485.422 port 9. LED indicator IES618-4F-4DI(RS-485)-P(12/48VDC) 7. RS-485/422 port 10. LED indicator Back view Top and below view IES618-2F-4D(RS-232)-P(12/48VDC) IES618-2F-4DI(RS-485)-P(12/48VDC) IES618-4D(RS-232)-P(12/48VDC) 7. RS-232 port 9. LED indicator 7. RS-232 port 10. LED indicator 7. RS-232 port 10. LED indicator

IES618-4F-4D(RS-232)-P(12/48VDC) IES618-4D series provide 4 bits industry terminal block (V1-, Top panel provided 4 bits DIP switch to do function V1+, V2-, V2+)), V-, V+ is 12~48VDC power supply input. configure( is default factory),1 and 4 keep for future IES618-4D series DC power supply input supported redundancy function, provided PWR1 and PWR2 power input, can use for single, and can connect 2 separately power supply system, use 1 pair terminal block connect the device at the same function. 3 is recovery default factory. 2 is for upgrade. Please power off and power on when you change the status of DIP switch. Communication connector time. If one of the power system broke, the device can work 10/100BaseT(X) Ethernet port un-interruptible. built-in over current protection, Reverse The pinout of RJ45 port display as below, connect by UTP or STP. 7. RS-485/422 port connection protection Console port IES618-4D series provided 1pcs procedure test port based in serial port. It adopts RJ45 interface, located in top panel, can The connect distance is no more than 100m. 100Mbps is used 120 Ωof UTP 5, 10Mbps is used 120Ωof UTP 3,4,5. 10. LED indicator configure the CLI command through RJ45 to DB9 female cable. Appearance and dimension RJ 45 port support automatic MDI/MDI-X operation. can Unit(mm) connect the PC, Server, Converter and HUB.Pin 1,2,3,6 Corresponding connection in MDI. 1 3,2 6,3 1,6 2 are used as cross wiring in the MDI-X port of Converter and HUB. Relay connection 10Base-T/100Base-TX are used in MDI/MDI-X, the define of Pin in the table as below. NO. MDI signal MDI-X signal 1 TX+ RX+ 1 8 2 TX- RX- Vertical view Top view 3 RX+ TX+ Power supply input Back view The relay owns two contacts of the terminal block on the top panel of IES618-4D series. It is used to detect both power failure and port failure. The two wires attached to contacts form an open circuit when: (1) IES618-4D series has lost power supply from one of the DC power inputs. 6 RX- TX- 4, 5, 7, 8 Note: TX± Transmit Data±, RX± Receive Data±, Not Use MDI (straight-through cable) (2) One of the ports is failure. DIP switch Vertical view Top view

MDI-X (Cross over cable) PIN RS-232 1 DCD 2 RxD 3 TxD MDI/MDI-X auto connection makes IES5028-4GS-2F easy to use for customers without considering the type of network cable. 4 DTR 5 GND 6 DSR 7 RTS 8 CTS 9 RS-485/422 LED indicator IES618-4D series LED indicator light on the front panel.the function of each LED is described in the table as below: System status LED LED Indicator Description 100Base-FX Fiber port 100Base-FX full-duplex SM or MM port, SC/ST type.the fiber port must be used in pair, TX (transmit) port connect remote switch s RX(receive) port; RX(receive) port connect remote switch s TX(transmit) port. PWR1 PWR2 P1 connection regularly P1 Power supply have no connection or unwonted P2 connection regularly P2 Power supply have no connection or unwonted The optical fiber connection supports the line to instruct enhance the reliability of network effectively. Suppose: If you make your own cable, we suggest labeling the two sides of the same line with the same letter (A-to-A and B-to-B, shown as below, or A1-to-A2 and B1-to-B2). RS-485 port: DB9 male (RS-232) PIN RS-485 1 D+ 2 D- 3 / 4 / 5 / Alarm Run Link/Act Blinking Blinking Power, port have alarm Power, port have no alarm Device unwonted Device working steadily, Blinking per second Established effective network connection Network in activity status Did not establish effective RS-422 port: network connection RS-232 port: PIN RS-422 1 T+ 2 T- 3 GND 4 R+ 5 R- TX Blinking Transmit data unwonted Transmit data wonted RX Blinking Receive data unwonted Receive data wonted Installation Before installation, confirm that the work environment meet the

installation require, including the power needs and abundant space. Whether it is close to the connection equipment and other equipments are prepared or not. 1. Avoid in the sunshine, keep away from the heat fountainhead or the area where in intense EMI. 2. Examine the cables and plugs that installation requirements. 3. Examine whether the cables be seemly or not (less than 100m) according to reasonable scheme. 4. Screw, nut, tool provide by yourself. 5. Power: redundant 12-48VDC o power input 6. Environment: working temperature -40~75 Relative humidity 5%~95% DIN rail installation In order to use in industrial environments expediently, IES618-4D series adopt 35mm DIN-Rail installation, the installation steps as fellows: 1. Examine the DIN-Rail attachment 2. Examine DIN Rail whether be firm and the position be suitability or not. 3. Insert the top of the DIN-Rail into the slot just below the stiff metal spring. 4. The DIN-Rail attachment unit will snap into place as shown below. Wiring Requirements Cable laying need to meet the following requirements, 1. It is needed to check whether the type, quantity and specification of cable match the requirement before cable laying; 2. It is needed to check the cable is damaged or not, factory records and quality assurance booklet before cable laying; 3. The required cable specification, quantity, direction and laying position need to match construction requirements, and cable length depends on actual position; 4. All the cable cannot have break-down and terminal in the middle; 5. Cables should be straight in the hallways and turning; 6. Cable should be straight in the groove, and cannot beyond the groove in case of holding back the inlet and outlet holes. Cables should be banded and fixed when they are out of the groove; 7. User cable should be separated from the power lines. Cables, power lines and grounding lines cannot be overlapped and mixed when they are in the same groove road. When cable is too long, it cannot hold down other cable, but structure in the middle of alignment rack; 8. Pigtail cannot be tied and swerved as less as possible. Swerving radius cannot be too small (small swerving causes terrible loss of link). Its banding should be moderate, not too tight, and should be separated from other cables; 9. It should have corresponding simple signal at both sides of the cable for maintaining. Specification Technology Standard: IEEE802.3, IEEE802.3u, IEEE 802.3x, IEEE802.1Q, IEEE802.1p, IEEE802.1D, IEEE802.1W Protocol: ARP, ICMP, TCP, UDP, DHCP, DNS, HTTP, Telnet, SW-RingTM Flow control: IEEE802.3x, back pressure control Function Function: SW-RingTM, QOS, 802.1Q VLAN, port-trunking, static multicast filter, port mirroring, Broadcast storm control, flow statistics, upgrade online, up and download configuration file, user name access system. SW-RingTM: Single, Couple, Chain, Dual homing ring. Serial device server: 4 port serial device sever, each port support 4pcs TCP or UDP session connection Interface 100M Ethernet: 10/100Base-TX self-adapt RJ45 port. 100M fiber port: 100Base-FX (SC/ST/FC) Console port: Procedure debug (RS-232), RJ45 Alarm port: 2 bit 7.62mm terminal block, 1 channel relay alarm output Serial RS-232 signal:txd,rxd,rts,cts,dtr,dsr,gnd RS-422 signal: T+, T-, R+, R-, GND RS-485 signal: D+, D-, GND Parity: None,Even,Odd,Space,Mark Data bit: 5bit,6bit,7bit,8bit Band rate; 300~115200bps Direction control: RS485 side adopt ADDC technology, auto detect and control data transfer direction Loading: RS-485/422 side support 32 nodes loop back Protection: 2KV isolation, 15KV static protection. Connector: RS232: DB9 male, RS485/4225 bit terminal block Transfer distance Twisted cable: 100m(CAT5/CAT5e) Multi mode fiber: 1310nm,2Km Single mode fiber: 1310nm, 20K, 1310nm, 40Km 1310nm, 60K, 1550nm, 80Km RS-485/422: 1200m RS-232: 15m

Exchange attribute: 100M transmit speed: 148810pps Transfer: Store and forward System exchange bandwidth: 2.0G Buffer memory: 1MKbit Support 2K MAC address table LED indicator Power supply indicator: PWR Alarm indicator: Alarm System indicator: Run Ethernet port indicator: Link/Act(1-8) Serial port indicator: TX(1-4), RX(1-4) Power supply Input voltage: 24VDC(12~48VDC) Terminal block: 4 bits 7.62mm terminal block IES618-4D(RS-232)-P(12/48VDC) None load consumption: 1.5 W@24VDC Full load consumption: 3.5 W@24VDC IES618-4DI(RS-485)-P(12/48VDC) None load consumption: 1.8 W@24VDC Full load consumption: 3.9 W@24VDC IES618-4F-4DI(RS-485)-P(12/48VDC) None load consumption: 4.8W@24VDC Full load consumption: 6.9W@24VDC IES618-2F-4D(RS-232)-P(12/48VDC) None load consumption: 3.2W@24VDC Full load consumption: 5.0W@24VDC IES618-2F-4DI(RS-485)-P(12/48VDC) None load consumption: 3.58W@24VDC None load consumption: 4.75W@24VDC Full load consumption: 6.14W@24VDC Support dual redundant power supply Support inside over-current 4.0A protection Support opposite connection protection Mechanical Shell: IP40, high strength iron shell. Installation: DIN Rail Dimension(W H D: 160 mm 70mm 130mm Weight: 1021g Environmental Operating Temperature: -45 C to 75 C Storage Temperature: -45 C to 85 C Relative Humidity: 10 to 95% (non-condensing) Standard EMI: FCC Part 15, CISPR (EN55022) class A EMS: EN61000-4-2 (ESD), Level 4 EN61000-4-3(RS), Level 3 EN61000-4-4 (EFT), Level 4 EN61000-4-5 (Surge), Level 4 EN61000-4-6(CS), Level 3 EN61000-4-8(PFM), Level 5 Shock: IEC 60068-2-27 Free fall: IEC 60068-2-32 Vibration: IEC 60068-2-6 Warranty Warranty time: 5 years Certification CE, FCC, RoHS, UL508(Pending) Full load consumption: 5.35W@24VDC IES618-4F-4D(RS-232)-P(12/48VDC)