TOSLINE-S20 Active Star Coupler Instruction Manual

Similar documents
TOSLINE-S20. Active Star Coupler(ASC25) Instruction Manual

Installation Job Aid for Ethernet Routing Switch 3600 Series

ADC7520 SERIES. 1600W Battery Chargers and Power Supplies

CVH Slot Media Converter Chassis Quick Installation Guide

Total Reach ISDN/DDS Isolation Card P P30059 Isolation Card

OPERATING INSTRUCTIONS 7 SERIES STATIC GENERATORS

FVT Slot Media Converter Chassis w/ Redundant Power User Manual

Analog Voltage Combination Module

Serial Data DIN Fiber Link System

HITACHI. EH-150 series PLC EH-RTD8 Resistance Temperature Detective input module Instruction manual. Safety precautions

Manual Simatek Control Unit GFC 32

Manual Control Unit GFC 32

USER MANUAL SES-FA4BAL

H Series PLC. ! : Indicates Compulsion. EH-150 Analog input module EH-AXH8M Instruction manual. Safety precautions DANGER CAUTION COMPULSION

Safety Relay Unit (I/O Unit Type)

MC 11 EB-2 Power supply cabinet with external bus, AC version

Installation Job Aid for VSP 4850GTS

WSK INTELLIGENT TEMPERATURE AND HUMIDITY CONTROLLER USER MANUAL

Installation Job Aid for VSP 4450GTX-HT- PWR+

BGS (at min. setting) BGS (at max. setting)

D6030S - D6030D INSTRUCTION MANUAL. D SIL 3 Switch/Proximity Detector Repeater Relay Output. Models D6030S, D6030D

2. Actuator B: Ball type P: Pin type F: Flat type

4170 POS System Installation Guide

INSTRUCTION MANUAL. SIL 3 Switch/Proximity Detector Repeater Relay Output, Termination Board Models D6032S, D6032D

DIO-1616LN-FIT. Features. Specifications. Ethernet Remote I/O F&eIT N Series Isolated Digital Input/Output Unit DIO-1616LN-FIT 1. Ver.1.

TOP - 1. Instruction Manual. Version 1.0 Produced in Jan. 2004

LED W RGBA User Manual

FL MC 2000T. Fiber optic converter for 10/100Base-Tx to single- or multi-mode fiberglass with SC-duplex and ST connections. Data sheet 3379_en_B

D1093S INSTRUCTION MANUAL. D SIL 3 Relay Output Module with Line and Load diagnostics. DIN-Rail Model D1093S

Preface. Copyright 1997, Digital Electronics Corporation MS-DOS and Windows 95 are registered trademarks of the Microsoft Corporation.

INSTRUCTION MANUAL. SIL 3 Relay Output Module DIN-Rail Models D1092S-069, D1092D-069 D1092S D1092D-069

ATS-16 HV USER MANUAL. Automatic Transfer Switch 16A / 230Vac V090318

Installation RA5112-C-16A-C20. Basic Rack Power Distribution Unit

QUALITY POWER SOLUTIONS BACKED UP BY REAL-WORLD ENGINEERING EXPERIENCE

Manual Control Unit GFC 16

FSW-1610TX FSW-2410TX

4-port 10/100TX + 1 or 2-port 100FX Industrial Switch. User Manual

Zenith DS9000 Dispensing System

16/24 Port Desktop & Rack-mountable Gigabit Ethernet Switch

PowerFlex 700S and 700H Frame 11 Replacement Power Structures

Features: SF108-CR v1.1 SF108-CR 10-ports switch for 8 IP cameras in enclosure with recorder space

Dell SC7020 Storage Controller Getting Started Guide

CMU 100 RS485 to 7x, 6x, 5x, 4x Multimode Fiber Optic Star Coupler User Manual

Infilex GD Multipurpose Data Gathering Panel Model WY5310

ControlKeeper 4. General Information. Connecting Relay Loads. Installation Sheet. Getting Started. Power Supply Wiring. Mounting the Cabinet

TE100-S16 16-Port 10/100Mbps Fast Ethernet Switch. User s Guide

LED PANEL. User Manual Please read the instructions carefully before use LED-7TC. Innovation, Quality, Performance 15-

ControlNet Comm Glass Fiber Adapter Kit

EC07 EC63. Compatible actuators: ERL2 ESD2. How to order EC 07 B. Series. B Installation. method

Features and Benefits. Certifications

Appearance Size (mm) Power supply voltage Model (W H D) 100 to 240 VAC K3SC to 240 VAC

Hardened PoE Ethernet Switch

KSD-800 Series. Installation Guide. Industrial 8-Port Fast Ethernet Switches with Fiber Connectivity DOC A -1-

FL MC 2000E (SM40) LC

OTB1C0DM9LP I/O distributed module OTB - CANopen bus m

GOLANDER PUMP. Operation Manual. For Microflow Variable-Speed Peristaltic Pump BT50S/BT102S.

INSTRUCTION SHEET. Eaton Logic Controller ELCB Controllers

Rack Mount Power Supplies

8-Port IP40 IEEE802.3af PoE Unmanaged Industrial Switch User s Manual

INSTRUCTION MANUAL DISTRIBUTION UNIT. Please read this manual thoroughly before use, and keep it handy for future reference.

OTB1E0DM9LP I/O distributed module OTB - Ethernet TCP/IP m

CMU 100 RS232 to Singlemode Fiber Optic Converter User Manual

Safety Monitoring Relays

Switched Mode Power Supply Operating manual PAP800

E3FS. Connect up to 4 sets of E3ZS/E3FS per B1 Module for F3SX Safety Controller

Superfeed SVF 888 Variable Frequency Controller

Remote I/O Product Specification

ClearCube F6151 Media Converter Chassis System with 10/100BaseTX to 100BaseFX Converter

S66 Series Electronic Fan Speed Control

USER'S GUIDE FX-485ADP COMMUNICATION ADAPTER FX0N-485ADP COMMUNICATION ADAPTER

Model : ON-PS3016G. 16 Port 10/100/1000Mbps Gigabit + 2 Gigabit SFP Uplink Unmanaged PoE Switch

Overview. Features CHAPTER

onlinecomponents.com

EMC1600 Series Media Converter and Ethernet Extender Chassis

Mini-DVI-WP Series WALL PLATE MINIATURE MULTIMODE FIBER OPTIC DVI TRANSMISSION SYSTEM

10W LED PIN SPOT. User Manual LED-PS10D W. Innovation, Quality, Performance. Professional Entertainment Technology 11-

Remote I/O Product Specification

TE100-DX16R/DX24R/DX32R 16/24/32 Ports Ethernet/Fast Ethernet Dual-Speed Stackable Hubs User s Guide

Omnitron Systems Technology, Inc. 1. iconverter. 19-Module Managed Power Chassis User s Manual

CMU 100 Multimode Fiber Optic to Singlemode Fiber Optic Converter User Manual

Industrial Serial RS-232 to Fiber Converter. KSC-200 Series. Installation Guide

Access Terminal IF-800

Accessories and options

Cabinet Interface Device

Total Reach ISDN/DDS Isolation Card P VDC to 24VDC External Power Supply P30060 Description & Installation

SRT2-ROC08, SRT2-ROC16

R-150 DMX Light Source

E3S-A. Built-in Amplifier Photoelectric Sensor (Medium Size) Ordering Information. Built-in Amplifier Photoelectric Sensors. Horizontal. 7 m.

Installation Job Aid for Avaya Virtual Services Platform 8400

Part No. Z , IA Mar OPERATION MANUAL. High Voltage Digitalmeter A

Visualize the actual worksite status! Simple and Intelligent I/O Slave Units.

Making Hazardous Operations Safe and Productive

DVI Extender over single LC Fiber with TMDS video and EDID data.

Can eliminate static charge over an extensive range

GSW-1657 GSW User's Guide. 16/24-port Gigabit Ethernet Switch. Ver

AUD-340 Installation Guide

MODEL: M5DY SEN TRONIC AG CURRENT LOOP SUPPLY. [2] POWER INPUT AC Power M: V AC (Operational voltage range V, Hz)

4 Channel Contact Closure DIN Fiber Link System

3-Phase, Dual-Input 6-Slot Power Supply System STARTUP GUIDE

CMU 100 RS485 to Ethernet Converter User Manual CMU 100 / CMU 100 / 1.M.9 CMU 100 / 1.L.9 CMU 100 / CMU 100 / 7.M.9 CMU 100 / 7.L.

Transcription:

TOSLINE - S20 Active Star Coupler Instruction Manual September, 1995 Toshiba International Corporation UM-TLS20**-E004

Table of Contents 1. Introduction... 2 2. Overview... 3 3. Specifications... 4 3.1 Specification summary... 4 3.1.1 General specifications... 4 3.1.2 Functional specifications... 5 3.2 Function... 6 4. Hardware... 7 4.1 Product construction... 7 4.2 System configurations... 8 4.3 External dimensions... 10 4.4 Component identifications... 11 4.5 Component function... 11 4.6 LED display... 12 4.7 Communication cable connection... 13 4.8 Power cord connection... 15 4.9 HEALTHY contact... 15 4.10 Fuse replacement... 16 4.11 Installation methods... 17 4.11.1 Installation inside an enclosure... 17 4.11.2 Loose installation... 18 4.11.3 Panel-mount installation... 18 5. Startup and Power-down methods... 19 5.1 Startup method... 19 5.2 Power-down method... 19 6. Cautions for use... 20 TOSLINE S20 1

1. Introduction This instruction manual explains how to use an Active Star Coupler (ASC22) in a TOSLINE-S20 data communication network. Instruction manuals for other TOSLINE-S20 components are listed below. System designers, device designers, and maintenance personnel using a TOSLINE-S20 network should refer to these manuals for information about how these components can be used in a TOSLINE-S20 network. x T2 / T3 stations UM-TLS20**-E001 x SIF (Serial Interface) station 6F3B0532 x Loader software S-LS (Ver 1.1) 6F3B0351-2 - Active Star Coupler Users Manual

2. Overview The Active Star Coupler (ASC22) is used for distributing fiber optic signals in a TOSLINE-S20 network. The TOSLINE-S20 is a Bus-style transmission system. If the power is off in one of the stations on this bus, communication is not possible before or after that station. To prevent this from happening, an Active Star Coupler can be used. If the Active Star Coupler is used, a station that is off will have no effect on the rest of the transmission system. U 250V - 3A TOSLINE- S20 V ACTIVE STAR COUPLER G CH1 CH2 CH3 CH4 CH5 CH6 CH7 CH8 CH9 CH10 O PWR P O O O O O O O O O O O O O O O O O O O O O COMM N TX RX TX RX TX RX TX RX TX RX TX RX TX RX TX RX TX RX TX RX TOSHIBA Figure 2.1 Exterior view Figure 2.1 shows the exterior of the Active Star Coupler. There are 10 sets of Transmit (TX) and Receive (RX) ports. Also, rubber feet are used on the bottom of the device. TOSLINE S20 3

3. Specifications This section presents the specifications for the Active Star Coupler. 3.1 Specification summary 3.1.1 General specifications General specifications for the Active Star Coupler are shown below. Item Specifications Voltage Rating AC100/110V, 50/60Hz AC200/220V, 50/60Hz Range AC85~132V, 47~66Hz AC170~250V, 47~66Hz Power Power consumption 10 VA (approx.) Supply Power-loss ride-through time < 10 msec, normal operation Insulation rating AC1500V for 1 minute Fuse rating 250V - 3A Temp Operation temp 0 ~ 55 C (unit ambient temperature) Storage temp -20 ~ 75 C (unit ambient temperature) Environ- Humidity 20 ~ 90%, no condensation ment Conforms to JIS C 0911 Vibration Power OFF / Freq: 16.7Hz / Displacement: 3mm Atmosphere Non-corrosive Dust Density less than 1mg/m 3 Ground 100ý: or less Measurements 390W x 200D x 70H mm Weight 3.0 kg Cooling Natural air cooling Installation position Horizontal (cannot be installed vertically or upside-down) Table 3.1 General specifications - 4 - Active Star Coupler Users Manual

3.1.2 Functional specifications Functional specifications for the Active Star Coupler are shown below. Item Specification No. of stations 10 stations maximum Cable Silica glass GI 50/125Pm (core dia. / clad Optic dia.), JIS C 6820 fiber Connector FC connector (JIS C 5970) Transmission distance Station - Star coupler: 1km max. Star coupler - Star coupler: 1 km max. Station - Station: 10 km max. Daisy-chained ASC s 9 maximum Connectable devices TOSLINE-S20 fiber optic network stations * HEALTHY contact (Relay contact) ON during Normal operation Contact ratings: AC 250V 1A DC 24V 1A Table 3.2 Functional specifications * HEALTHY contact: ON if the power supply is within specifications and at least one port is operating normally. (At the same time, the COMM LED will also be lit.) If no stations are connected, the HEALTHY contact will be OFF. TOSLINE S20 5

3.2 Function This section describes the function of the Active Star Coupler. (1) When the Active Star Coupler receives a signal at one of its ten ports, it transmits this signal (unchanged) from its remaining nine ports. 10 9 8 7 1 6 A S C 2 3 4 5 Data input at port 1 Data output from ports 2 ~ 10 Figure 3.1 Function of the Active Star Coupler (2) The Active Star Coupler has two LEDs for displaying its operation status. x When the power supply is within specification, the PWR LED (green) is lit. x When the power supply is OK and the unit is transmitting normally, the COMM LED (green) is lit. (3) If the PWR LED is not lit, please check the power supply. If the COMM LED is not lit, please check the power supplies of the Active Star Coupler and all of the stations connected to it. - 6 - Active Star Coupler Users Manual

4. Hardware This section describes the hardware of the Active Star Coupler. 4.1 Product construction Part name Rating Š Type form Qty Comment 1 Active Star Coupler ASC22 1 Product Code: SASC22*US 2 Fuse AC250V - 3A 2 One is installed in the device, another is included as a spare 3 L-brackets 1 Attached to device before shipment 4 Power Cord 1 Option Table 4.1 Product construction TOSLINE S20 7

4.2 System configurations The systems shown below are possible when using the Active Star Coupler. (1) Basic configuration As shown below, up to ten stations can be connected to one Active Star Coupler. STN ASC STN......................... STN Figure 4.1 Basic configuration (2) Station-to-station daisy-chain configuration STN STN ASC STN STN STN Figure 4.2 Station-to-station daisy-chain configuration - 8 - Active Star Coupler Users Manual

(3) Active Star Coupler daisy-chain connection As configured below, the Active Star Coupler (ASC) can be daisy-chained to up to nine other ASC s. The total number of stations (STN) cannot exceed 64. STN ASC ASC STN STN STN Figure 4.3 Active Star Coupler daisy-chain configuration (4) Typical example A typical example of the TOSLINE-S20 fiber optic network with T2 PLC and G3 ASD stations is shown below. T2 PLC T2 PLC ASC Up to 8 ASD s................ G3 ASD G3 ASD G3 ASD Figure 4.4 Typical example TOSLINE S20 9

4.3 External dimensions TOSLINE-S20 Units (mm) Figure 4.5 External dimensions - 10 - Active Star Coupler Users Manual

4.4 Component identifications The names of the different parts on the Active Star Coupler are shown below. Terminal Optic connectors LED p Fuseholder p p p TOSLINE-S20 Rubber feet Note: Fiber optic connectors are in pairs of Transmit (TX) and Receive (RX) connectors Figure 4.6 Designation of front-panel components 4.5 Component function below. The functions of the individual components on the Active Star Coupler are shown Item Function Comment Status LEDs (PWR, COMM) Operation status display Terminal block Power supply input and relay contact Fuseholder Power supply protection Transmit connector, TX Fiber optic connection (transmit) Reception connector, RX Fiber optic connection (receive) Table 4.2 Function of front-panel components TOSLINE S20 11

4.6 LED display Status LEDs are located on the front panel of the Active Star Coupler. These LEDs indicate the operation of the Active Star Coupler. (1) Display and labels TOSLINE-S20 ACTIVE STAR COUPLER CH9 CH10 { PWR Both LEDs are green { { { { { COMM TX RX TX RX TOSHIBA (2) Description Figure 4.7 LED display and labels LED Description PWR (power) Indicates whether the power supply is within specification. ON Power supply is OK OFF Power is not within specifications or fuse is open COMM (communication) ON Power supply is OK and a signal is being received. OFF ASC s power supply is OFF, power supplies of all stations are OFF, or no stations are connected Table 4.3 LED displays - 12 - Active Star Coupler Users Manual

4.7 Communication cable connection The Active Star Coupler uses fiber optic transmission cable. The method for connecting this cable is described below. For information about cable distribution and wiring, please refer to the Installation & Wiring manual (6E3B0533). (1) Connection cable Fiber optic cable: Silica Glass GI (JIS C6820) (core diameter: 50Pm / clad diameter: 125Pm) Note: For cable details, please refer to the Installation & Wiring manual (2) Connector locations and designations The connectors are located on the front panel. There are ten pairs of Transmit (TX) and Receive (RX) connectors. (3) Cable connection When making cable connections, connect the Transmit (TX) connector of the Active Star Coupler to the Receive (OR) connector of the station (TOSLINE S-20 module). Likewise, connect the Receive (RX) connector of the Active Star Coupler to the Transmit (OT) connector of the station. When connecting two Active Star Couplers together, connect the Transmit (TX) connector of one Active Star Coupler to the Receive (RX) connector of the other. Likewise, connect the Receive (RX) connector of the first Active Star Coupler to the Transmit (TX) connector of the second. Note: On the Active Star Coupler, CH1 ~ CH10 channels can be selected. (The channels are in TX - RX pairs.) OT1 OR1 OT2 OR2 TX RX TX RX Active Star Coupler Station Figure 4.8 Active Star Coupler - Station connection TOSLINE S20 13

Fiber Optic Cable TX RX TX RX TX RX TX RX Active Star Coupler Active Star Coupler Figure 4.9 Active Star Coupler daisy-chain connection Notes: x When connecting the fiber optic cable, be careful not to get dirt on the terminals. Also, the optic components are very delicate. Be careful not to cause unnecessary shock or use too much force when making connections. For information about handling and cleaning the optic components, please refer to the Installation & Wiring manual. x Please cover all ports that are not in use. - 14 - Active Star Coupler Users Manual

4.8 Power cord connection Please connect a 3-pole power cord to the power supply terminals of the Active Star Coupler. Then, insert the plug into a 3-pole electrical outlet. Please do not connect the power supply terminals to any other power supply. O U AC 100 / 200V V terminals G Ground LED P HEALTHY contact N terminals Power Source O AC100/200V 3-pole plug Figure 4.10 Power cord connection When the Active Star Coupler is connected to a power supply, its power supply LED indicates whether or not the power supply is within specifications. Note: Switching between 100 / 200Vac is not necessary. 4.9 HEALTHY contact The HEALTHY contact indicates the status of both the power supply and whether or not communication is taking place. The ON/OFF conditions of the contacts are listed below. HEALTHY Contact HEALTHY Contact Conditions ON Power supply is OK and at least 1 of the 10 ports is operating normally OFF Power supply is OFF or no stations are connected Table 4.4 HEALTHY contact ON/OFF conditions HEALTHY contact ratings: 1A / 24VDC or 250Vac TOSLINE S20 15

4.10 Fuse replacement If the unit is connected to a power supply, but the PWR LED is not lit, the fuse may be open. If this situation occurs, remove the power supply, replace the fuse on the front panel of the Active Star Coupler and try powering up the unit again. Fuse rating: 3A / 250V - 16 - Active Star Coupler Users Manual

4.11 Installation methods The Active Star Coupler can be mounted inside an enclosure, allowed to stand loose, or mounted to a panel. 4.11.1 Installation inside an enclosure Active Star Coupler p 250V-3A TOSLINE-S20 ACTIVE STAR COUPLER CH1 CH2... CH9 CH10 { PWR { { { { { { { { { COMM TX RX TX RX TX RX TX RX L-bracket p TOSHIBA Shelf m Support 370 Figure 4.11 Mounting an Active Star Coupler inside an enclosure 130 150 1 20 Units (mm) Figure 4.12 L-bracket Use L-brackets and M5 screws (12 ~ 20 mm) to secure the Active Star Coupler to a shelf. When installing the unit this way, remove the rubber feet from the bottom of the unit. (The L-brackets are secured to the Active Star Coupler before shipment.) TOSLINE S20 17

4.11.2 Loose installation The Active Star Coupler can be set on a table-top or other secure flat surface. There are rubber feet on the under-side of the Active Star Coupler. If the L-brackets are in the way, they can be removed by first removing the screws on the side of the unit. If you remove the L-brackets, make sure to replace all of the screws. Caution: Stacking the Active Star Coupler may cause damage. Do not stack or place objects on top of the Active Star Coupler. 4.11.3 Panel-mount installation Use the L-brackets when mounting the Active Star Coupler to a panel. Do not mount the Active Star Coupler vertically or upside-down. When using the L-brackets, remove the rubber feet from the bottom of the unit. Acceptable Installation Position Horizontal Top Side Right Vertical Unacceptable Installation Positions Upside-down Wrong Wrong Figure 4.13 Installation orientation - 18 - Active Star Coupler Users Manual

5. Startup and Power-down methods 5.1 Startup method (1) Connect power cables to the Active Star Coupler and to each of the stations connected to the Active Star Coupler. (2) Connect transmission cables between the Active Star Coupler, stations, and any other Active Star Couplers (daisy-chain configuration) that are to be used. (See section 4.7 for details concerning transmission cable connections.) (3) Apply power to the Active Star Coupler and to each of its connected devices. (Note: It is not important which device is powered-up first.) (4) Begin transmission at each station. (Refer to the individual instruction manuals for each station.) (5) Once the above steps are complete, the Active Star Coupler should begin operating. 5.2 Power-down method (1) Remove the power supplies from the Active Star Coupler and each of the connected devices. (Note: It is not important which device is powered-down first.) TOSLINE S20 19

6. Cautions for use Please observe the following cautions when using the Active Star Coupler. x x x Do not remove the top cover When using fiber optic cable, do not let the optic connectors become dirty. Also, because the optic components are precision components, do not subject them to shock or unnecessary force. For details about handling and cleaning the optic components, please refer to the Installation & Wiring manual. Cover optic connectors when not in use. This mark indicates DANGER. It is applied at those places where misapplication could cause harm or injury. Where this mark is applied, observe the following caution: The safety cover over the terminal block on the front panel has a sharp angle. Use caution when handling. - 20 - Active Star Coupler Users Manual