HT101. User terminal. Function

Similar documents
Touch screen operator unit

mark150s mark150/485s DDC controllers Summary

IMIO100 IMIO105. DDC controllers. Summary

MXPLC. Compact PLC process station. Summary. Application HVAC control systems, data acquisition, interfacing 3 rd party systems.

Evo2. Free programmable room controller. Summary

UC102 basic version with display and knob UC102BL version with display, knob and backlight UC102DK version without knob and display

Communicative controller for VAV systems

MXIO. Compact I/O module. Summary. Application Compact I/O module for data acquisition and HVAC control systems. Function

Modbus TCP/RTU MP-Bus converter

Note: the wiring of the dead-man buttons has been changed since October 2001.

Communication over Modbus protocol Connection with multiple controllers Application upgrade by using an SD 1) card or a USB stick

F1000 User's Manual. (Version: V1.01)

Communicative heating controller, Ethernet

4-1. This chapter explains HMI settings.

Energy Web Server. Viale Borri 231, Varese - Italy. Cat. no: PM1WS255

4-1. This chapter explains HMI settings.

CLIMATIX STEQ, STCM DATASHEET FOR CONTROLLING, SWITCHING AND MONITORING FUNCTIONS. POWER SUPPLY RELAY OUTPUTS. Power supply. 4.

Control Panel CP600 CP651, CP651-WEB

Mini Energy Web Server

EC-PU4. Processor unit with 4 communication ports

DATA SHEET Advanced Graphical Interface, AGI 100 series

Control Panel CP600-eCo CP604, CP604-B

Control Panel CP600 CP635, CP635-B, CP635-WEB

Ethernet in Machines and Installations 0

M-bus web server. Meters and Energy Cost Allocation WTV676-HB6035

NI TSM-101x. LCD Characteristics NI TSM-1012 NI TSM-1015 SPECIFICATIONS. NI TSM-1012, NI TSM-1015, NI TSM-1017 Touch Screen Monitors

Web interface BACnet/IP

HMI HUMAN MACHINE INTERFACE

User Manual. cmt-svr Startup Guide

User Manual. cmt-svr Startup Guide

Machine TV Interface. mtv-100. Memory Processor. I/O Port RTC. Power. Specification. Certificate Software

Document ID: 1VCD Product Name: MyRemoteCare Gateway Document Name: Operation Manual Issued: Revision: R0001 Product Version: 1.

Control Panel CP600 CP635-FB, CP635-FW

EXOcompact. Third generation freely programmable controllers

epalm10 Product Manual

Aport-212PG Programmable Device Server User Guide

UniOP epad30, epad32. Tech-note PN# tn171-3.doc - 03/10/ Ver Highlights

etop Series 500 Operating Instructions

General information. Display. Control elements

exware Series Operating Instructions

-U- Type discontinued

dyne Motion Control Hydraulic Pneumatic Electrical Mechanical (80 ex700 Series The Revolutionary IIoT Controller

Operating Instructions 12/2010 MN Z-EN XV-152 MICRO PANEL

Operating Instructions SECUTEST SI /12.10

PXR11 PXR12. System controllers DESIGO PX

PIGEON RB100-CM3. Features. Applications

2 Device description. 2 Device description 2.1 Function. 2.1 Function. 2.2 Intended use. 2.3 Device versions

Compact HMI devices with 9 function keys, numerical keypad and 20 characters display.

256 MB RAM. 256 MB 32 bits RISC Cortex-A8 600MHz SD Card Slot. N/A USB Host. N/A USB Client

General information Customer-specific configuration

Industrial Control SE-607

PWS6300S Operating Guide HITECH. Introduction

DVBCommunity - cообщество профессионалов ЦТВ 4IN1 DVB-S2 IP/SPTS IRD with 4CI >>User Manual

DS2020SingleAxis ExtremelyCompact ServoDrives

DeviceMaster RTS 16-Port Hardware Installation

The possibility of combining interface modules allows various bus and network systems to be integrated into the B&R SYSTEM 2005.

General information. Display. Control elements

UniOP epad03 and epad04

5.2 CP0201, CP0291, CP0292

crio PN Installation Instructions V0.2/ COMSOFT

TM221CE40R controller M IO relay Ethernet

A-307. Mobile Data Terminal. Android OS Platform Datasheet

epowerswitch-8 Power Management Master Slave User's Guide

Operator units CDPX Key features

Power Meter PowerMonitor 500

Installation and User Manual. version 1.00 MODWF 2014/53/UE EN : /30/UE EN55022:2010 EN :2005 EN :2007

HUDGE STORAGE MEMORY TO CATER FOR FUTURE EXPANSION OPTO ISOLATION FOR BETTER NOISE PROTECTION

TM221CE24T controller M IO transistor PNP Ethernet

This guide provides basic information for Unitronics controllers V C30B and V T40B.

MODEL: GR8-EM. Communication Adaptor GR8 Series

APP 700 Technical Specification

CPC 01/02. Description. x86 Computer Module. Datasheet

TM221ME16T controller M IO transistor PNP Ethernet

DVB-S/S2 to IP UDP/MPTS Gateway User Manual

RTU560 Connections and Settings DIN Rail RTU 560CIG10

Domino DFWEB. DFWEB: interface module between Domino bus and Ethernet network with Web-Server function. Module Connection. Domino

iopac 8020 Series Rugged modular RTU controllers Overview Programmable RTU Controllers Ethernet bypass feature for seamless data transmission

EY-WS 500: Web server for moduweb Vision and moduweb500 BACnet networks

SK CU4-PNT-C Part number:

Designed for commercial, residential and industrial applications, guarantee rapid installation with few and easy connections.

JetBox 9300/9310 User Manual. Hardware

MT-8000 series. MT-8056T/ MT-6056T Installation Instruction. 1.0 Installation and Startup Guide. 2.0 Installation Instructions

ACE PLUS CORP. APCON100 series Operation Manual RS-232 to Ethernet Converter

TruVision IP Thermal Camera Installation Guide

Installation Guide V1210-T20BJ This guide provides basic information for Unitronics controllers V1210-T20BJ.

Technical Manual Nova: Cabinet Security Management System (CSMS)

USER MANUAL. Longo programmable controller LPC-2.MC8 Main module. Version 10

TM221M16TG controller M IO transistor PNP spring

ewon Flexy 2 Serial Ports Ext. Card FLA 3301

TM221M32TK controller M IO transistor PNP

PXM20-E. Operator unit BACnet auf Ethernet/IP DESIGO PX

OnRISC. OnRISC Baltos ir 2110

BACnet router for BACnet/IP BACnet/LonTalk BACnet MS/TP

Poseidon 4002 MANUAL

Win-GRAF ViewPAC. Features. Introduction. Windows Embedded Compact 7. Win-GRAF. Win-GRAF ViewPAC Series

USER MANUAL. Longo programmable controller LPC-3.IOR.001 Input Output Relay PLC. Version 2

Installation Guide V1210-T20BJ This guide provides basic information for Unitronics controllers V1210-T20BJ.

Installing the Cisco Unified Videoconferencing 3545 MCU

CONTENTS INTRODUCTION. System overview...2. Axis module...3 Interface...3 Technical characteristics and environmental data...4 Dimensions...

Compact HMI devices with 5 function keys, numerical keypad and 20 characters display.

Transcription:

HT101 User terminal Summary HT101 is a human-machine interface for monitoring and control of multiple MiniPLC, IPCT.1, IPCB.1 controllers, or other SoftPLC runtimes working on different platforms. It has one Ethernet interface. This type has more memory compared to HT100. Application Control panel for free-programmable control units for HVAC systems or other technologies Terminal for receptions and rough environments overview and control of remote technologies Function The terminal is controlled by six buttons and LCD display 4x20 characters with backlight. The communication interfaces is Ethernet (web configuration or SoftPLC). The program status is indicated by RUN LED located at the back panel together with the Power indication LED. For default IP address (192.168.1.82) set the DIP SW3 to ON and power the device; at the same time, the menu file is not loaded and the terminal is ready for diagnostics (INIT state). DIP SW4 disables the web interface and FTP access this may be used for increased network security. After menu upload and restart, the display shows menu with tree structure (maximum 32 items in one submenu and 56 time schedules) and the terminal starts to communicate with the process devices. Maximum number of SoftPLC RT connections is 8. Users move in the menu using buttons the active line is the second from the top, which is enhanced by the red line on the printed cover. Objects such as Value setting, Alarm, and Time schedule have predefined functionality, and thus for the configuration it is only necessary to set addresses, assign data points, and complete user texts. The menu is uploaded to the terminal Flash memory either through SoftPLC Touchscreen Editor, or over FTP protocol into the file system of the terminal over the Ethernet interface. A file named J.txt is uploaded. The default IP address is 192.168.1.99. domat HT101 06/2016 Subject to technical changes. 1

The device is installed using four metal clamps into an aperture in panel door or any suitable box. The aperture dimensions are 93 x 145 mm, with tolerance +2 mm. Application examples: see domat Design and application guide. Technical data Power 24 V AC/DC ± 10%; 3 W Communication LCD display Buttons 4x LED Ethernet Number of connections HW 1x Ethernet 10/100BaseT 4 rows x 20 characters, blue backlight 6 buttons on a membrane keyboard, water and dirt resistant RUN, PWR, RS485 RX/TX (are not supported for this type) Ethernet 10/100BaseT, RJ45 max 8 connections SoftPLC RT ARM Cortex M4 168 MHz, 10 MB FLASH, 256 KB SRAM, 4 KB NVRAM SW SoftPLC Touchscreen editor (since version 2015/4/15) maximum number of time schedules 56 maximum number of submenu 32 Front panel dimensions Aperture dimensions see schema below see schema below Protection degree IP65 (EN 60529) Recommended wire diameter 0,35-1,5 mm 2 Ambient temperature 0 60 C Standards conformity EU legislation EMC EN 61000-6-2 ed.3:2005, EN 55022 ed.3:2010 EN 60950-1 ed.2:2006 + A11:2009 + A12:2011 + A1:2010 + A2:2014 EN 50581:2012 Council Directive 2006/95/EC, health and low voltage equipment safety Council Directive 2004/108/EC, electromagnetic compatibility Council Directive 2011/65/EC, certain hazardous substances in electrical and electronic equipment 2 06/2016 Subject to technical changes. domat HT101

Terminals Terminals and connectors: G G0 TE Ethernet LED indication: RxD TxD power power optional connection for shielding network interface not used not used PWR green LED power (ON: power OK; OFF: no power applied, weak or damaged power supply, ) RUN yellow LED system cycle (OK: LED flashes periodically 1 s ON, 1 s OFF; ERROR: LED flashes in other pattern, LED is still ON or OFF) DIP switches: DIP1 and 2 INIT WEB not used INIT - Switch DIP ON, switch OFF/ON power supply. Menu is not displayed and IP is set to default 192.168.1.99, mask 255.255.255.0 web and FTP disabled increased network security domat HT101 06/2016 Subject to technical changes. 3

Dimensions Installation aperture: Dimensions are in mm. 4 06/2016 Subject to technical changes. domat HT101

Configuration The menu definition is uploaded in terminal through RcWare HMI Editor or through web interface. Other settings could be configure through service web. RcWare HMI Editor Create the HT101 menu definition. The principles of creation menu are described in the LCD menu manual: http://domat-int.com/en/downloads/technicaldocumentation, RcWare SoftPLC Touch Screen Editor. Note: The connection parameters to a particular PLC must be correctly set. The terminal needs to know from which PLC the variables should be read. The connection settings is defined in File -> Variables Manager -> select a connection and Show advanced tools -> Connections -> Update / Edit Connection. After uploading the list of variables in the HMI project, the connection must be set as Remote Connection and correct communication parameters must be entered. The changes must be confirmed by the Apply changes button. Example: The whole definition can be finally uploaded through File -> Upload menu definition to HT100/101. The editor creates a.txt definition file and uploads it to the device using FTP protocol. The correct IP address, user and password for FTP must be set (see below). As an alternative, it is possible to File -> Export menu definition for HT100/101 and create.txt definition file which can be uploaded through the HT101 web pages. After uploading menu definition the device must be restarted for the changes to apply. Service web The HT101 service web can be accessed over a web browser on the device IP address (the browser PC must be in the same network). In Settings there is network configuration. It is possible to upload/download the menu definition and upload new version of HT101 application. domat HT101 06/2016 Subject to technical changes. 5

Communication The default network settings are: IP address 192.168.1.99 subnet mask 255.255.255.0 default gateway 192.168.1.1 User for FTP: root Password for FTP: root99 Notice: Do not forget to note the new network settings after change! RoHS notice The device contains a non-rechargeable battery which backups the real-time clock and part of the memory. After the device is not operable, please return it to the manufacturer or dispose of it in compliance with local regulations. 6 06/2016 Subject to technical changes. domat HT101

Changes in versions 07/2015 First version. 05/2016 Changed terminals labels. Added schema with dimensions. 06/2016 Added chapter Configuration and Communication. domat HT101 06/2016 Subject to technical changes. 7