Whole Body MRI Intensity Standardization

Similar documents
A Model-Independent, Multi-Image Approach to MR Inhomogeneity Correction

Basic principles of MR image analysis. Basic principles of MR image analysis. Basic principles of MR image analysis

Supplementary methods

Learning-based Neuroimage Registration

MEDICAL IMAGE COMPUTING (CAP 5937) LECTURE 4: Pre-Processing Medical Images (II)

Machine Learning for Medical Image Analysis. A. Criminisi

Fmri Spatial Processing

Utilizing Salient Region Features for 3D Multi-Modality Medical Image Registration

DUE to beam polychromacity in CT and the energy dependence

A Non-Linear Image Registration Scheme for Real-Time Liver Ultrasound Tracking using Normalized Gradient Fields

NIH Public Access Author Manuscript Proc SPIE. Author manuscript; available in PMC 2013 December 30.

Chapter 3 Set Redundancy in Magnetic Resonance Brain Images

Separate CT-Reconstruction for Orientation and Position Adaptive Wavelet Denoising

Hybrid Spline-based Multimodal Registration using a Local Measure for Mutual Information

Normalization for clinical data

STIC AmSud Project. Graph cut based segmentation of cardiac ventricles in MRI: a shape-prior based approach

NIH Public Access Author Manuscript Proc SPIE. Author manuscript; available in PMC 2013 December 31.

MR IMAGE SEGMENTATION

Automatic Subthalamic Nucleus Targeting for Deep Brain Stimulation. A Validation Study

Norbert Schuff VA Medical Center and UCSF

Classification of Subject Motion for Improved Reconstruction of Dynamic Magnetic Resonance Imaging

An Introduction To Automatic Tissue Classification Of Brain MRI. Colm Elliott Mar 2014

SPM8 for Basic and Clinical Investigators. Preprocessing. fmri Preprocessing

Preprocessing II: Between Subjects John Ashburner

Basic fmri Design and Analysis. Preprocessing

Methods for data preprocessing

A Study of Medical Image Analysis System

PROSTATE CANCER DETECTION USING LABEL IMAGE CONSTRAINED MULTIATLAS SELECTION

COMPREHENSIVE QUALITY CONTROL OF NMR TOMOGRAPHY USING 3D PRINTED PHANTOM

Functional MRI in Clinical Research and Practice Preprocessing

Generation of Hulls Encompassing Neuronal Pathways Based on Tetrahedralization and 3D Alpha Shapes

MEDICAL IMAGE NOISE REDUCTION AND REGION CONTRAST ENHANCEMENT USING PARTIAL DIFFERENTIAL EQUATIONS

The Anatomical Equivalence Class Formulation and its Application to Shape-based Computational Neuroanatomy

Comparison Study of Clinical 3D MRI Brain Segmentation Evaluation

Global Thresholding Techniques to Classify Dead Cells in Diffusion Weighted Magnetic Resonant Images

Image Registration + Other Stuff

Image Segmentation and Registration

Respiratory Motion Estimation using a 3D Diaphragm Model

Brain Extraction, Registration & EPI Distortion Correction

Image Registration I

Improvement and Evaluation of a Time-of-Flight-based Patient Positioning System

HST.583 Functional Magnetic Resonance Imaging: Data Acquisition and Analysis Fall 2008

Biomedical Image Processing for Human Elbow

New Technology Allows Multiple Image Contrasts in a Single Scan

Neuroimaging and mathematical modelling Lesson 2: Voxel Based Morphometry

Super-resolution Reconstruction of Fetal Brain MRI

SPM8 for Basic and Clinical Investigators. Preprocessing

Empirical cupping correction: A first-order raw data precorrection for cone-beam computed tomography

Image Acquisition Systems

Reduction of Metal Artifacts in Computed Tomographies for the Planning and Simulation of Radiation Therapy

3/27/2012 WHY SPECT / CT? SPECT / CT Basic Principles. Advantages of SPECT. Advantages of CT. Dr John C. Dickson, Principal Physicist UCLH

3D VISUALIZATION OF SEGMENTED CRUCIATE LIGAMENTS 1. INTRODUCTION

EMSegmenter Tutorial (Advanced Mode)

Supplementary Information

MEDICAL IMAGE ANALYSIS

Semi-automated Basal Ganglia Segmentation Using Large Deformation Diffeomorphic Metric Mapping

Histograms. h(r k ) = n k. p(r k )= n k /NM. Histogram: number of times intensity level rk appears in the image

Evaluation of Local Filter Approaches for Diffusion Tensor based Fiber Tracking

Radon Transform and Filtered Backprojection

3-D Compounding of B-Scan Ultrasound Images

Ensemble registration: Combining groupwise registration and segmentation

Fuzzy C-means Clustering For Retinal Layer Segmentation On High Resolution OCT Images

RADIOMICS: potential role in the clinics and challenges

Where are we now? Structural MRI processing and analysis

fmri pre-processing Juergen Dukart

Performance Evaluation of the TINA Medical Image Segmentation Algorithm on Brainweb Simulated Images

Norbert Schuff Professor of Radiology VA Medical Center and UCSF

Optimization of Reconstruction of 2D Medical Images Based on Computer 3D Reconstruction Technology

Medicale Image Analysis

Medical Image Registration by Maximization of Mutual Information

Projection and Reconstruction-Based Noise Filtering Methods in Cone Beam CT

Edge-Preserving Denoising for Segmentation in CT-Images

CAD SYSTEM FOR AUTOMATIC DETECTION OF BRAIN TUMOR THROUGH MRI BRAIN TUMOR DETECTION USING HPACO CHAPTER V BRAIN TUMOR DETECTION USING HPACO

ADAPTIVE GRAPH CUTS WITH TISSUE PRIORS FOR BRAIN MRI SEGMENTATION

TEMPLATE-BASED AUTOMATIC SEGMENTATION OF MASSETER USING PRIOR KNOWLEDGE

Atlas Based Segmentation of the prostate in MR images

EPI Data Are Acquired Serially. EPI Data Are Acquired Serially 10/23/2011. Functional Connectivity Preprocessing. fmri Preprocessing

Automatic Registration-Based Segmentation for Neonatal Brains Using ANTs and Atropos

Non-Rigid Image Registration III

2.1 Signal Production. RF_Coil. Scanner. Phantom. Image. Image Production

ECSE 626 Project Report Multimodality Image Registration by Maximization of Mutual Information

Landmark-based 3D Elastic Registration of Pre- and Postoperative Liver CT Data

Available Online through

Using K-means Clustering and MI for Non-rigid Registration of MRI and CT

On Standardizing the MR Image Intensity Scale

Image Registration. Prof. Dr. Lucas Ferrari de Oliveira UFPR Informatics Department

TomoTherapy Related Projects. An image guidance alternative on Tomo Low dose MVCT reconstruction Patient Quality Assurance using Sinogram

Detection of Unique Point Landmarks in HARDI Images of the Human Brain

Spatio-Temporal Registration of Biomedical Images by Computational Methods

Critique: Efficient Iris Recognition by Characterizing Key Local Variations

Diffusion MRI Acquisition. Karla Miller FMRIB Centre, University of Oxford

A Multiple-Layer Flexible Mesh Template Matching Method for Nonrigid Registration between a Pelvis Model and CT Images

Norbert Schuff Professor of Radiology VA Medical Center and UCSF

Slide 1. Technical Aspects of Quality Control in Magnetic Resonance Imaging. Slide 2. Annual Compliance Testing. of MRI Systems.

Digital Volume Correlation for Materials Characterization

Annales UMCS Informatica AI 1 (2003) UMCS. Registration of CT and MRI brain images. Karol Kuczyński, Paweł Mikołajczak

Fiber Selection from Diffusion Tensor Data based on Boolean Operators

Deep Learning for Fast and Spatially- Constrained Tissue Quantification from Highly-Undersampled Data in Magnetic Resonance Fingerprinting (MRF)

Shape-based Diffeomorphic Registration on Hippocampal Surfaces Using Beltrami Holomorphic Flow

Prostate Detection Using Principal Component Analysis

Transcription:

Whole Body MRI Intensity Standardization Florian Jäger 1, László Nyúl 1, Bernd Frericks 2, Frank Wacker 2 and Joachim Hornegger 1 1 Institute of Pattern Recognition, University of Erlangen, {jaeger,nyul,hornegger}@informatik.uni-erlangen.de 2 Department for Radiology and Nuclear Medicine, Charité, Campus Benjamin Franklin, Berlin, {bernd.frericks,frank.wacker}@charite.de Abstract. A major problem of segmentation of magnetic resonance images is that intensities are not standardized like in computed tomography. This article deals with the correction of inter volume intensity differences that lead to a missing anatomical meaning of the observed gray values. We present a method for MRI intensity standardization of whole body MRI scans. The approach is based on the alignment of a learned reference and the current histogram. Each of these histograms is at least 2-d and represents two or more MRI sequences (e.g., T1- and T2-weighted images). From the matching a non-linear correction function is gained which describes a mapping between the intensity spaces and consequently adapts the image statistics to a known standard. As the proposed intensity standardization is based on the statistics of the data sets only, it is independent from spatial coherences or prior segmentations of the reference and newly acquired images. Furthermore, it is not designed for a particular application, body region or acquisition protocol. The method was evaluated on whole body MRI scans containing data sets acquired by T1/FL2D and T2/TIRM sequences. In order to demonstrate the applicability, examples from noisy and pathological image series acquired on a whole body MRI scanner are given. 1 Introduction For magnetic resonance imaging no protocol dependent intensity standard, like the Hounsfield units in computed tomography, is available due to magnetic field inhomogeneities in both B 0 and RF excitation fields. One type of variation is that intensities of the same tissue class differ throughout a single volume. In order to deal with that problem, a variety of algorithms for bias field correction were developed in the last decade. However, these methods do not solve the other type of problem: a certain measured intensity cannot be associated with a tissue class. The distinction of both kinds of variations is illustrated in Figure 1. For segmentation, a missing protocol dependent standard intensity scale has the disadvantage that for every new suspect an individual training of the used (statistical) model has to be performed. For this reason the clinical applicability of many algorithms is low due to runtime restrictions. Furthermore, visualization

Fig. 1. The distinction of both types of variations (inter and intra scan inhomogeneities). The first image shows the original FL2D scan of a patient. The second image shows the same slice after gain field correction. In the third image a threshold of 580 is applied to the gain field corrected slice. The last image shows a FL2D scan of another patient after gain field correction with the same threshold applied. systems cannot use standard presets (e.g., transfer functions) to visualize certain organs or tissue classes. The settings have to be adjusted for every single scan. Hence, a second class of approaches dealing with inter-scan intensity standardization was developed by several authors. State-of-the-art algorithms, generally, standardize the observed intensities using a single image at a time and ignore spatially adjacent images. For many applications this is sufficient, because in many regions of the body a gray value in one image is associated with exactly one intensity in another sequence (e.g., the brain). In general, however, this is not the case. The algorithm presented in this article utilizes all acquired images for intensity standardization. With that, it is possible to separately correct tissue classes that have the same intensity in one image but can be distinguished using more data sets. Furthermore, the introduced approach does not rely on any assumptions about the shape of the joint histograms used. Thus the method is completely independent from the application, region of interest (brain, thorax, pelvis, etc.), scanning protocol (e.g., T1-, T2-weighted) as long as there are learned histograms available for the task. In [1] a 1-d histogram matching approach was presented. First, they detected some landmarks (percentiles, modes,...) on the template and the reference histogram, matched them and finally interpolated linearly between the detected locations. Pierre Hellier presented in [2] a correction method for MRI brain images that estimates a mixture of Gaussians that approximates the histogram first. Then he computes a polynomial correction function that aligns the mean intensities of the tissues. A multiplicative correction field is estimated in [3], that adapts the intensity statistics of an acquired MR volume to a previously created model. This is achieved by minimizing the Kullback-Leibler divergence between the model and the template intensity distribution. In [4] a method including spatial information between the reference and the template image is presented. In order to match the images a non-linear registration algorithm was used. On the aligned images a scalar multiplicative correction weight is computed. How intensity standardization and bias correction influence each other is evaluated in [5]. The authors conclude that both steps are necessary but the correction of inhomogeneities has to be done beforehand.

Spatial Domain Intensity Domain Spatial Domain Reference Images Reference Histogram Deformation Field Corrected Images Current Images Current Histogram Fig. 2. Schematic illustration of the intensity standardization. First, from the reference images a reference joint histogram is created. This is the training component of the approach. Then from the current MRI images a joint histogram is generated. In the next step these histograms are non-rigidly registered. Using the gained transformation function, the current images are standardized. 2 Methods The goal of the intensity standardization approach is to find a mapping between the intensities of a set of images U = (U 1, U 2,..., U n ), where n is the number of images and a reference set of images R = (R 1, R 2,..., R n ) so that an intensity vector i I n describes the same tissue class in both sets with I n being the intensity space of the image sets [6]. The main idea of this contribution is that this mapping can be approximated by the minimization of the distance between the joint relative histograms of the two sets of images. The required relative joint histograms have a dimensionality of n. The domain is IR n. In general, however, it can be scaled to [0, 1] n due to the limited number of gray values observed. The relative joint histograms of the two tuples will usually never be equal (at least for real data sets) as the volume of the same tissue class in the image set U and R differs for inter- as well as for intra-patient measurements (e.g., partial volume averaging effects, positioning of the patient). Thus the search for a mapping between the intensity spaces is equivalent to finding the deformation between the relative joint histograms H(R) and H(U) so that they are closest with respect to a given distance measure. If the joint histograms are treated as images, this task can be viewed as non-rigid image registration [7]. The used whole body MRI data sets are very large, thus the influence of small local structures on the appearance of the histogram is very low. For this reason we split the volume in K sub volumes. These sub volumes are than corrected separately. However, in order to guarantee a common gray level standard, the other K 1 histograms are used as additional regularizer. Consequently our new

Fig. 3. First row: head region of the reference image (FL2D), the reference image (TIRM), the template image (FL2D) and the template image (TIRM). Second row: Thresholded images, FL2D protocol (Reference, Template, Result). The threshold for the binarization of all images is the same. The effect of the intensity standardization can be seen best in the brain area. distance measure can be written as D i [H(R), H(U); u i ] = K a i,k D[H(R k ), H(U k ); u i ], k=1 K a i,k = 1, (1) where i is the current sub volume and a i,k is the influence of the force of sub volume k in the context of the standardization of block i. D is a distance measure like sum of squared differences or mutual information. R k and U k are the k th sub volumes and u i is the current deformation field. The result of the optimization is the transformation T : IR n IR n. In the case of the registration of multi-dimensional relative joint histograms, it describes how to transform the gray values of one set of images U such that its intensity distribution best matches the reference distribution, with respect to the used distance measure and smoother. Here a curvature based smoother was used. Thus the intensity standardization can be done by i corr = T (i orig ). k=1 3 Results All data sets were acquired on a Siemens Avanto 1.5 T whole body MRI scanner. The TIRM images had a resolution of 512 512 30 (each block) with 0.98 mm 2 and 5.5 mm slice thickness and TE = 83 and TR = 1660 and the FL2D images had a resolution of 512 410 30 (each block) with 0.98 mm 2 and 5.5 mm slice thickness and TE = 4.7 and TR = 291. The size of the composed whole body images was 542 1746 20 for both protocols. Only the composed volumes were used for the experiments. All images were acquired in clinical routine. In total ten whole body MRI data sets were used for evaluation. We divided the volumes in K = 5 blocks along the y-direction. Thus each block had a size of 542 350 20. The size of a joint histogram was 128 128

pixel. The registration of one histogram took about one second. Using these settings, the overall computational time for the standardization was about seven seconds. The difference µ d of the mean intensities of the data sets was chosen as quality measure. For the TIRM images this resulted in a difference of µ d = 6.4 before and µ d = 3.2 after the standardization. As the TIRM images do not have many visible structures in the legs, the histograms are very blurred in these regions. Thus no reliable registration is possible. After removing these regions (block four and five) from the evaluation we got a difference of µ d = 7.0 before and µ d = 2.3 after standardization. Figure 3 illustrates the effect of the standardization. 4 Discussion In this article we present a new method for MRI intensity standardization of whole body MRI scans. In contrast to most of the previously published methods, the proposed approach is independent from any prior knowledge about the structure of the data sets and it relies on the image statistics only. Hence, there is no prior registration or segmentation of the data sets necessary. Furthermore, the method is independent from the application, body region and imaging protocol, if learned joint histograms are available. The most important improvement is that the proposed method utilizes all acquired images jointly and does not perform the standardization of the images separately. However, if the image statistics are too different, the obtained results may not be satisfying. This is the case, for instance, for volumes disturbed by a strong bias field. This yields blurred histograms and thus no reliable registration is possible anymore. References 1. Nyúl, L.G., Udupa, J.K., Zhang, X.: New variants of a method of MRI scale standardization. IEEE Transactions on Medical Imaging 19 (2000) 143 150 2. Hellier, P.: Consistent intensity correction of MR images. In: International Conference on Image Processing (ICIP 2003). Volume 1. (2003) 1109 12 3. Weisenfeld, N., Warfield, S.: Normalization of joint image-intensity statistics in MRI using the Kullback-Leibler divergence. In: IEEE International Symposium on Biomedical Imaging. Volume 1. (2004) 101 104 4. Schmidt, M.: A method for standardizing MR intensities between slices and volumes. Technical Report TR05-14, University of Alberta (2005) 5. Madabhushi, A., Udupa, J.K.: Interplay between intensity standardization and inhomogeneity correction in MR image processing. IEEE Transactions on Medical Imaging 24 (2005) 561 576 6. Jäger, F., Deuerling-Zheng, Y., Frericks, B., Wacker, F., Hornegger, J.: A new method for MRI intensity standardization with application to lesion detection in the brain. In: Vision Modeling and Visualization. (2006) 269 276 7. Modersitzki, J.: Numerical Methods for Image Registration. Oxford University Press, Oxford New York (2004)