QXA2000 QXA2001. Condensation Monitor QXA2001 QXA2000 AQX2000

Similar documents
Universal Modules. Synco 700. Extension modules for use with controls of the Synco 700 family. Use

RMZ782B RMZ783B. Extension Modules. Building Technologies HVAC Products. Synco 700. for heating controller RMH760B

RXM39.1. PL-Link IO Block. Desigo TRA. Use with PXC3 series room automation station

Room Temperature Controller

Heating Circuit Controller

Room Temperature Controller

Non-communicating room controllers

Immersion Temperature Sensors

RMZ782B RMZ783B. Extension Modules. Building Technologies HVAC Products. Synco 700. for heating controller RMH760B

Heating Circuit Controller

Duct Sensors. Building Technologies HVAC Products. Symaro. for relative humidity and temperature with calibration certificates

Room Temperature Controllers

RXC39.5. Room controller. Building Technologies. Desigo RXC. Communicating room controller for fan-coil applications

Power supply module, bus connection module

Room unit with PPS2 interface

DESIGO RX Individual room controllers. for fan-coil systems, chilled ceilings and radiators, with LONMARK-compatible bus communications

RXB39.1. Room controller RXB. Communicating room controller for fan-coil applications FC-13

TXM1.8T. Triac module Used for Thermic and motor-driven actuators (AC 24 V) TX-I/O

Universal Controller

Temperature controller Ducted systems

ERF910. RF Repeater. Synco living

Room sensors QFA4160 QFA41 D AQF4150 AQF3153. Symaro. for relative humidity and temperature with calibration certificates

Extension module for lighting control

RXL24.1. Room controller RXL. Communicating controller for chilled ceiling and radiator applications CC-02

Rotary version, three-position control

Electrical Actuators

Electrical Actuators

Non-communicating room controllers

Semi flush-mounted room temperature controllers with LCD

Electrical Actuators

Semi Flush-mount Room Temperature Controllers with LCD

Temperature Controller (Heat Pumps)

Semi flush-mounted room temperature controllers with LCD

Resistance measuring module

Temperature Controller

SEH62.1. Digital Time Switch

Room Temperature Controller with 7-Day Time Switch, LCD and opt. Remote Temperature Sensor

Master room unit for RRV controllers

Rotary actuators for ball valves

TXM1.8RB. TX-I/O Blinds module

M-Bus Central Unit. Use

Air damper actuators

Switching and Monitoring Device

SAX.. ACVATIX Electromotive actuators for valves. with a 20 mm stroke

Extension module Integration of existing PTM I/O modules in Desigo Used with PXC50...D, PXC100...D or PXC200...D

RMZ792. Bus Operator Unit. Building Technologies HVAC Products. Synco 700

RXB10.1. Room controller. Siemens Building Technologies Building Automation DESIGO RXB. for chilled ceilings and radiators with EIB bus communication

Web interface BACnet/IP

Compact Universal Controllers

Use. Functions. OpenAir TM. Linear version, modulating, AC 24 V

Electromotoric actuators

TXM1.8U TXM1.8U-ML. Universal modules TX-I/O

Electromotive actuators for combi valves

RXL24.1. Room controller RXL. Communicating controller for chilled ceiling and radiator applications CC-02

Island bus expansion module

RDF301 RDF CE1N3171en 02 Jun 2010 Building Technologies

Digital input modules

M-bus web server. Meters and Energy Cost Allocation WTV676-HB6035

OEM. Room unit QAA822 with2- wire interface. Building Technologies CLIMATIX TM. For use with Climatix controllers

PHOENIX CONTACT - 07/2006

Heating Controllers. Siemens Building Technologies HVAC Products. Synco 700

RM22TG. Product data sheet Characteristics. three-phase control relay Vac, 2 C/O. Main. Complementary. Network number of phases

AEW Pulse Adapter. Building Technologies

TXM1.8U TXM1.8U-ML. Universal modules TX-I/O

EYE 200: DDC single-room controller, ecos200

Room unit with PPS2 interface

RM17UB3. Product data sheet Characteristics. voltage control relay RM17-U - range V AC. Main. Complementary

Central Communication Unit OZW775

Temperature controller for multi-zone ducted systems

RF adapter plugs, dimming

Compact universal controllers

Electrical actuators

QAX50.1 QAX50.5 QAX51.1 QAX51.5. Flexible room unit. Desigo RXC

Central control unit

Electromotoric actuators

QUINT-BUFFER/24DC/24DC/40

Electromotoric actuators

Switching module for AC V and up to three load stages, with manual switching

RM35UB3. Product data sheet Characteristics. voltage control relay RM35-U - range V AC. Main. Complementary

QVE3000.0xx QVE3100.0xx. Flow sensor. for liquids in DN10 25 pipes

Fast running actuators for air dampers

RM35JA32MR Current control relay 0.15A 15A, 2 C/O

Interface converter for VAV compact controllers

RXL21.1 RXL22.1. Room controllers RXL. Communicating controllers for fan-coil applications FC-10, FC-11, FC12

Operating instructions. Switching amplifier DN0210 DN / / 2015

Room unit with PPS2 interface

Super universal modules

s Climatix AHU ext. module 14 I/O POL955.XX/XXX Climatix

THERMASGARD TM 65. Immersion screw-in duct temperature measuring transducer, calibratable, with multi-range switching and active output TECHNICAL DATA

Operating instructions. Speed monitor D / / 2014

Product and functional description. Application Program. instabus EIB Technical product information. April (6 x AC 230 V / 0,05 A)

BACnet/IP Web Interface

LOGIC CONTROLLER INSTALLATION MANUAL NTR 756 B /E

Power Supply HARTING pcon

Room thermostat with KNX communications For VAV heating and cooling systems

RM17UAS. Product datasheet Characteristics. voltage control relay RM17-U - range V DC. Main. Complementary. Price* : 70.

Airflow Pressure Sensor

Room unit with PPS2 interface

RM17UB3. Price* : USD

Electromotoric actuators Torques up to 60 Nm Running times ¹) s. ¹) Predefined by the basic unit (LMV5...)

Transcription:

1 542 1542P03 1542P01 1542P02 QXA2001 QXA2000 AQX2000 Condensation Monitor QXA2000 QXA2001 The QXA2000 condensation monitor is used to avoid damage due to condensation on chilled ceilings and in HVAC plant. It operates on AC/DC 24 V and has a potential free AC/DC 1 48 V changeover contact. Suited for use with extension module AQX2000 (AC 230 V) equipped with a potential free AC 12 250 V changeover contact. Use For monitoring condensation in buildings with chilled ceilings or in ventilation, air conditioning or heating plant. The condensation monitor is used to prevent condensation on chilled ceilings to prevent condensation at critical spots of HVAC plant or buildings (in air ducts, near fans, etc.) as a condensation switch In general, the condensation monitor is for use on all kinds of surfaces where condensation must be avoided. Ordering and delivery When ordering the condensation monitor, please give name and type reference. It is supplied complete with a strap-on band for pipe diameters from 10 to 100 mm and thermal conductive paste. The AQX2000 extension module, which is offered as an accessory item, must be ordered separately. CE1N1542en 30.09.2010 Building Technologies

Equipment combinations Suited for use with all types of devices that operate on AC/DC 24 V and that can handle the condensation signal delivered by the monitor s potential free AC/DC 1...48 V relay changeover contact, or that, in connection with the AQX2000 extension module, operate on AC 230 V and that can handle the condensation signal delivered by the module s potential free AC/DC 12...250 V relay changeover contact Mode of operation With its sensing element, the condensation monitor acquires the relative humidity close to the dew point (=100 % r. h.). The resistance of the sensing element raises sharply in the range of 90...100 % r. h. Before the dew point is reached, the electronics energizes the relay. When, for instance, in the case of chilled ceiling applications, the relay contact switches over (2-position output), the following actions are triggered: 1. Cooling will be shut down via the valve or by a controller until the condensation signal is no longer present. 2. The water flow temperature will immediately be raised by an adjustable value (typically 1 to 2 K) and slowly reduced again after the signal has disappeared. This application requires a specific function in the controller. SD Q11 Q12 Q11 Q12 95 100 r. F. % Legend SD Switching differential Q... Relay contact output 1542D01 Mechanical design QXA2000 Housing with snap-on cover made of pure-white, flame-retarding thermoplastics with spring-loaded humidity sensing element, holding relay with changeover contact, connection terminals and Pg 11 cable entry glands made of plastics. 1 2 3 4 6 5 4 2 1 Q12 Q11 G G0 6 5 1542Z01 Legend 1 Sensing element 2 Fixing screw with strap-on band 3 Terminal block 4 Nose of snap-on facility 5 Slot, for lifting the cover with the help of a screwdriver 2/8

QXA2001 Versions such as QXA2000 have, however, offset sensor heads (fixed cable connection of 1.5 meters) rather than a directly integrated sensor. View: Sensor head on the mounting side View: Sensor head front side 1 Sensing element 2 Tensioning strap 3 Connector cable 1.5 m to base housing AQX2000 RXZ40.1 The AQX2000 extension module consists of base, top section and printed circuit board with the lateral connection terminals. The RXZ40.1 terminal cover is available as an optional item for use with the AQX2000 extension module. It provides protection against electric shock hazard and keeps the terminals free from dust and dirt. When fitting the terminal cover, it must be ensured that it engages correctly. Accessories 1542Z02 Removal of terminal cover Name Extension module AC 230 V Terminal cover Type reference AQX2000 RXZ40.1 Engineering notes The AQX2000 extension module operates on AC 230 V mains voltage. It feeds AC 24 V to the condensation monitor and delivers the condensation signal via its potential-free AC/DC 12...250 V relay changeover contact. Caution! Cable stain relief for the AC 230 V terminals is mandatory. The cables must be attached to the lugs on the base using cable ties (see illustration). 1542Z03 Caution! The AQX2000 extension module may only be accessed by authorized staff. 3/8

Disposal Dispose of the device as electronic waste in compliance with European directive 2002/96/EEC (WEEE) and not as municipal waste. Observe all relevant national regulations and dispose of the unit correctly. Observe all local and applicable laws. Mounting notes QXA2000 condensation monitor QXA2001 Mounting choices: Pipe-mounting with strap-on band (pipe diameter 10...100 mm) Surface-mounting on walls or ceilings with the help of 4 screws The condensation monitor performs its function only if the humidity sensing element assumes the same temperature as the surface to be protected against condensation. Following is to be noted: Apply a thin layer of thermal conductive paste on the mounting surface Mount the condensation monitor at the coldest spot of the chilled ceiling (plant) In the case of water-cooled chilled ceilings, mount the monitor on the water inlet pipe Protect the sensing element against aggressive chemicals and dirt (both can adversely affect the correct operation of the monitor and drastically shorten its life) Mounting choices of sensor head like QXA2000. Note AQX2000 extension module AC 230 V The monitor must not be continuously exposed to condensation. It is supplied complete with Mounting Instructions. Mounting choices: On top hat rails conforming to EN 60 715 TH 35-7.5 On walls (with the help of screws) The cable length to the condensation monitor must not exceed 20 m. Commissioning notes No special commissioning procedure is required. A functional test can be made by exhaling slowly onto the sensing element several times, thus simulating condensation. Caution! Do not expose the sensing element to tap water as this can cause electrolytic corrosion. Power lines AC 230 V Local regulations regulate sizing and fusing of power lines. Power lines must be fused in the extension module AQX2000 with strain relief. Potential-free Relay output The potential-free relay output permits switching loads of up to AC 250 V, 6 A. Line sizing is oriented to connected load and local regulations. The switching circuits are externally fused ( 10 A), there is not internal protection. The relay output is not suitable for connecting to SELV or PELV electric circuit. The lines must be fused with strain relief on the extension module AQX2000. 4/8

Technical data QXA2000, QXA2001 Power supply G (G+), G0 (G ) Functional data Operating voltage SELV/PELV AC / DC 24 V ± 20 % Rated voltage AC / DC 24 V Frequency 50 / 60 Hz Power consumption max. 1 VA Switching point on increase of humidity 95 ± 4 % r. h. Switching differential (fixed) approx. 5 % r. h. Response time in static air From 80 auf 99 % r. h. From 99 auf 80 % r. h. max. 3 min max. 3 min Condensation max. 30 min Output Q11, Q12, Relay output Current range at AC / DC 24 V Starting current at AC / DC 24 V Switching capacity potentialfree changeover contact 0.02...1 (1) A 10 A for 20 ms min. AC/DC 1 V, 1 ma max. AC/DC 48 V, 0.5 A Protection data Connections Degree of protection of housing IP 40 to EN 60 529 Safety class III to EN 60 730 Mechanically strap-on band for pipe dia. 10...100 mm Electrical connections Screw terminals for 1.5 mm 2 Environmental conditions Materials and colors Operation to Climatic conditions Temperature (housing with electronics) Humidity Mechanical conditions Transport to Climatic conditions Temperature Humidity Mechanical conditions Housing IEC 60 721-3-3 class 3K5 5...+ 50 C 5...95 % r. h. (noncondensing) class 3M2 IEC 60 721-3-2 class 2K2 25...+ 60 C < 95 % r. h. class 2M2 thermoplastics, pure-white Industry standards Product standard Automatic electrical controls for domestic use and similar applications EN 60 730-1 Electromagnetic compatibility Immunity Emissions CE conformity Electromagnetic compatibility conformity Australian EMC Framework Radio Interference Emmission Standard EN 61 000-6-2 EN 61 000-6-3 2004/108/EG Weight Including packaging 0.126 kg AS/NZS 61000-6-3 5/8

AQX2000 Power supply (L, N) Operating voltage AC 230 V ± 10 % Rated voltage AC 230 V Frequency 50 / 60 Hz Power consumption max. 4 VA Inputs Status signal input (D, GND) Contact voltage Contact current DC 37 V (SELV/PELV) 13 ma Outputs Voltage output (G, G0) Operating voltage Frequency at AC 24 V Load Relay output (Q11, Q12, ) Protective data Operating voltage range Operating current range Switching capacity AC 24 V ± 20 % (SELV/PELV) 50 / 60 Hz max. 1 VA potential free changeover contact Not suitable for connect to SELV/PELV electric circuits AC/DC 12...250 V 0.01...6 A min. AC/DC 12 V, 10 ma max. AC/DC 250 V, 6 A 1500 V Electrical insulation (L, N) Degree of protection of housing With terminal cover and wall-mounting without top hat rail IP 30 to EN 60 529 Safety class to EN 60 730 device suited for use with equipment of safety class I or II Connections Electrical connections Screw terminals for max. 2 x 1.5 mm 2 or 1 x 2.5 mm 2 Cable length to the QXA2000, QXA2001 max. 20 m Environmental conditions Materials Operation to Climatic conditions Temperature (housing with electronics) Humidity Mechanical conditions Transport to Climatic conditions Temperature Humidity Mechanical conditions Housing Terminal cover IEC 60 721-3-3 class 3K5 5...+ 50 C < 85 % r. h. class 3M2 IEC 60 721-3-2 class 2K3 25...+ 70 C < 95 % r. h. class 2M2 ABS + PC ABS + PC Industry standards Weight Product standard Automatic electrical controls for domestic use and similar applications EN 60 730-1 Electromagnetic compatibility Immunity (Industry) Emissions (Residential) CE conformity Electromagnetic compatibility Low-voltage directive Conformity Australian EMC Framework Radio Interference Emission Standard Including packaging EN 60 730-1 EN 60 730-1 2004/108/EG 2006/95/EG AS/NZS 61000-6-3 0.2 kg 6/8

Diagrams Internal diagrams QXA2000, QXA2001 G (G+) (G-) G0 r.f. % Q12 Q11 1542G01 G (G+) Operating voltage AC 24 V (DC 24 V) G0 (G ) System neutral Q... Potential free changeover contact AC / DC 1... 48 V AQX2000 G G0 D GND L N Q12 Q11 1542G02 G Operating voltage AC 24 V G0 System neutral D, GND Status signal input DC 37 V for potential free changeover contact of the QXA2000, QXA2001 L, N Mains voltage AC 230 V Q... Potential free changeover contact AC / DC 12...250 V Connection diagram L G (G+) G D L Q11 (G-) G0 Q12 Q11 F1 G0 GND N Q12 U1 N 1542A01 F1 Condensation monitor QXA2000, QXA2001 U1 Extension module AQX2000 (AC 230 V) 7/8

Dimensions QXA2000 QXA2001 AQX2000 Dimensions in mm Din Rail 8/8 2002-2010 Siemens Switzerland Ltd Subject to alteration