Bar Code Scanner Specifications for XL200 Controllers

Similar documents
Appendix A Cable Pinouts

Cable Pinouts. SRP I/O Module

GS2 Third Party Controller Harness Kit

Printer Interface (6370) Setup. Replaces discontinued Printer Interface (4370)

I/O Interface DNA300

ICP PANEL-TEC PEX3000 II

EX KVIS RS232/422/485 3-in-1 Serial to USB Adapter (w/ 4KV Isolation, 15KV ESD Surge Protection)

-C5RS-LC RS232 EXTENDER

E1 and T1 RJ-48 Cable Pinouts on page 208. Fast Ethernet 12-port Cable Pinouts on page 211

Intelligent Devices IDI 1100 Series Technical Manual

Introduction CAUTION. Setting Up the Scanner CAUTION

User Manual V1.1 Date: WiFi RS-232 Adapter. Red LED: IP Address Blue LED: TX/RX 5V Out (Pin 9)

EWAVE Inc Gracefield Ln. Dallas, Texas (972)

RS-232 Driver Module

Cabling Guide for Console and AUX

3.1 I-7560 Pin Assignment and Specifications: Introduction

Innovati s Bluetooth 100M Universal Wireless Bluetooth Module

MSS100 / MSS-VIA / MSS4 Quick Start Guide

Hardware Manual. PCMCIA 1 Port RS EDITION APRIL 1999

MS Protocol Converter. User Manual. Firmware version 2.0 ISI. Instrumental Solutions, Inc.

Hardware Manual PCMCIA DUAL RS EDITION MAY 1999

AudioReQuest Crestron XY Touch Screen Guide Version 1.0.0

IT 1910i. Industrial 2D-code hand-held scanner TECHNICAL DESCRIPTION. make technical changes EN /06. We reserve the right to

PCI Express 16-Port Serial I/O Cards

PCI Express 4-Port Industrial Serial I/O Cards

PACSystems* RX3i IC695CMM002-EG and IC695CMM002CA-EG IC695CMM004-EG, IC695CMM004CA-EG, and IC695CMM004LT-EG

USER MANUAL. G.shdsl+ modem with G.703 interface TAHOE 671 FREEDOM OF COMMUNICATION

MGate 5118 Quick Installation Guide

WiBox 2100 Quick Start Guide

Default COM Port, IRQ, and Baud Rate Jumper Settings

PowerView. Hub. by LUXAFLEX WINDOW FASHIONs

USER S MANUAL. PH232Ex1. #1 RS-232 Serial Port to Ethernet, Terminal Server/Client. Doc No: PH232Ex1-UM-001 IPEX. (IP Electronix)

How a 2d barcode scan engine to be integrated with your. I. The imager engine itself with TTL serial interface :

EtherSeries Modbus Gateway EMB-2 User s Guide

LM058 Bluetooth Serial Adapter SMA Antenna 100m m Range SPP GAP + Wireless DTR DSR RTS CTS

Matrix-700 Linux-Ready Cortex-A5 Industry IoT Gateway Hardware Guide

RN-WIFLY-EVAL-UM. WiFly Evaluation Kit Roving Networks. All rights reserved. RN-WIFLY-EVAL-UM-1.0 Version /8/2011 USER MANUAL

Matrix-605 WinCE ARM9 Industry Box Computer User Guide

Select a Data Communication Interface

PCIe Card Selection Guide. PCIe-CAN Card. PCIe-COM Card. Taiwan Pulse Motion Co.,Ltd. Bus Interface PCI Express x 1 LPE-C122 PCE-C122D PCE-C122T

PACSystems* RX3i IC695CMM002 and IC695CMM004

SCS100/200/400 Quick Start Guide

EASON HMI & MP9** series Products Note Yaskawa Systems Application Engineering Group

INSTALLATION GUIDE Maxiflex P3e CPU M1262F

CAS IKS Gateway (Modbus RTU/TCP and HTML) Manual

BioPointe Reader Installation Guide

EZL-200F Application Notes (003) Serial Interface (RS232/RS422/RS485)

Document Name : User Manual for SC10B : RS232 to Bluetooth Converter.

2D Image Handheld Scanner

APPENDIX B SERIAL I/O MODULE INSTALLATION / OPERATION WHEN USING T&D VER. 5.2 OR 5.3

Serial Communication Converters & Adapters Instruction Manual

DFS/Cutter. Debugging Communication Problems

WiFi to RS-232 adapter user manual

LM058 Bluetooth v2.0, v2.1 RS232 Serial Adapter - SMA Connector Standalone (With Embedded Bluetooth v2.0 / v2.1 Stack)

MGate 5105-MB-EIP Quick Installation Guide

Data Cable for GSP-2900 Fixed Satellite Phone. Installation Instructions. Revised July 2004

USBG-8COM-PRO 8-Port USB to RS-232, 422, 485 Auto Setup Adapter Manual. Features & Specifications. Specifications

Domain 3000 Back Panel

Hardware Reference. with DIL/NetPC ADNP/9200. Remote Access Gateway IGW/922

IDS-141A/181A. Industrial 4-port/8-port slim type serial to Ethernet device server. Features. Introduction. DS-Tool

Installation and Programming Manual

USER MANUAL. GSM Modem Option. Compatible with: DB46, DB7012

USB to RS-232/RS422/485. US-101-I USB To Serial Operation Manual

DGH A3000 Configuration Guide For use with DGH Modules

EtherSeries. EtherSeries CR-2. CR-2-Opto. User s Guide. Revised October 7, 2013 Firmware Version 1.X

NTI. KEEMUX Series. KEEMUX-P2 (2-Port PS/2 KVM Switch) INSTALLATION / USER GUIDE R NETWORK TECHNOLOGIES INCORPORATED

EX & EX-45362IS 2S RS232/422/485 3-in-1 Serial PCIe Card

Quick Start Installation Guide

IR Manager Just Add Power HD over IP Page 1 IR MANAGER. Revised

Lumio Release Note Lumio Multi-Touch Communication Protocol

RS-232 Connector Pin Assignments

3: Networking Options

Advanced 486/586 PC/104 Embedded PC SBC1491

USER MANUAL HPS-120. About this product: Your Communications Solutions Provider

NPort 6600 Series Quick Installation Guide

2D Image Hands-Free Scanner

Document Number: Rev. B

User Manual V1.2 Date: WiFi RS-232 Adapter. Red LED: IP Address Blue LED: TX/RX 5V Out (Pin 9)

UTS485 & ULOG485 USB Converter Owner's Manaul

ELAN DIGITAL SYSTEMS LTD. CF428 COMPACT FLASH CF+ CARD USER S GUIDE

Click-A-Tune. User Manual

MGate 5111 Quick Installation Guide

ISDA/ISDA4 Protocol Driver Manual. Table of Contents

Quick Start Guide. MS-820 Industrial Bar Code Scanner

Connecting a CNC to a PC wireless over WiFi

IML 560 USER GUIDE. Low Power 56Kbps Industrial modem. Version 1.2. December 6, AYANTRA Inc.

RS-232 Fiber Link Card System

Connector and Cable Specifications

TinyTrak4 v7 Hardware Manual

MGate 5105-MB-EIP Series

PVM1010 Inverter Data Monitoring Module

UTS400 series USB Converter

Linksys SPA 2102 ATA Setup & Troubleshooting Guide

ASYNC Sharing Unit TABLE OF CONTENTS SECTION 1 - DESCRIPTION...2 SECTION 2 - SPECIFICATIONS...5 SECTION 3 - INSTALLATION...7

Starter Guide Version Sphinx Access Control System

RA Triage Procedure. Product: DM8050 & DM8600 series. 1.0 Useful Components & Accessories

Plantronics Wireless Headset Installation Guide

28-Port 10/100/1000Mbps with. 4 Shared SFP Managed Gigabit Switch WGSW / WGSW-28040P. Quick Installation Guide

Nuscan 3200 Optical Laser Barcode Scanner

FSA-CU Configuration Utility Programming Guide

Transcription:

Bar Code Scanner Specifications for XL200 Controllers Scanner Specifications Any scanner connected to an XL200 series controller must conform to the following communication specifications: Baud Rate: 9600 Stop Bits: 1 Parity: None Data Bits: 8 Suffix: None (some scanners append a carriage return at the end of every scan by default) DB9 Port The DB9 port on the top of the XL200 controller has three uses: Scanner port Debug port Flash memory port DB9 Port Pinout 2 RS232 TX 3 RS232 RX 5 GND 7 RS232 CTS 8 RS232 RTS Pin 7 Pin 7 of the DB9 port is the Clear-to-Send input on the controller. A pull up resistor on that input keeps it high. In some RS232 applications, this input is toggled by the outside device s Request-to-Send (called handshaking). The XL200 controller does no handshaking, with either hardware or software, so it doesn t use pin 7 when communicating with other devices. However, a laptop connected to that port usually pulls pin 7 low, which informs the controller to set up the port for a debug/flash. 1

Note: Make sure the scanner is configured so that it does not pull pin 7 low. If the scanner pulls pin 7 low for any reason, the controller will not configure itself for a scanner. The input is retested on every power up. Note: The scanner should be setup so that its ground matches the AMS ground, and its TX goes to the AMS RX. No other connections are necessary for scanner communication. Zebra LI3608 Bar Code Scanner Setup Note: The following setup procedure works only with the Zebra LI3608 bar code scanner. For other bar code scanners, please contact the manufacturer for proper setup procedures. When a Zebra LI3608 bar code scanner is connected to an XL200 series controller for the first time, the scanner must be setup to properly communicate with the controller before it can be used for data entry. Setup Procedure 1. Turn on the scanner. The scanner plays a musical tone, indicating it is on. 2. Verify that the Power Light on the Power Supply is on. 3. Turn off the XL200 series controller, but leave the scanner turned on. 4. Scan the bar code below. Do not proceed to the next bar code until you hear a beep confirming the scanner has read the bar code. 5. Once the bar codes are read, the setup is complete and the scanner is ready for operation. 6. Turn the XL200 Series Controller on. NOTE: This particular scanner does not have the capability of turning off the RTS/CTS (pin 7 and Pin 8) signal as described on page 1 of this document, therefore, pin 7 and Pin 8 of the DB9 Connector MUST be clipped or removed for proper operation of the scanner. See the troubleshooting section for more details. 2

Symbol DS3408 and LS3408 Bar Code Scanner Setup Note: The following setup procedure works only with the Symbol DS3408 and LS3408 bar code scanner. For other bar code scanners, please contact the manufacturer for proper setup procedures. When a Symbol DS3408 or LS3408 bar code scanner is connected to an XL200 series controller for the first time, the scanner must be setup to properly communicate with the controller before it can be used for data entry. Setup Procedure 1. Turn on the scanner. The scanner plays a musical tone, indicating it is on. 2. Turn off the XL200 series controller, but leave the scanner turned on. 3. For wireless scanners, use the scanner to scan the wireless base first. Failing to do this will prevent the bar code scanner from functioning properly. 4. Scan this bar code: Scanner Startup Bar code When the scanner successfully scans the bar code, it beeps. 5. Turn on the controller. a. If the scanner makes any sound while the controller boots, you must repeat the scanner setup process. b. If the scanner remains silent while the controller boots, the scanner is successfully setup. 3

Sick IDM160-300S Corded Bar Code Scanner Setup Note: The following setup procedure works only with the Sick IDM160 bar code scanner. For other bar code scanners, please contact the manufacturer for proper setup procedures. When a Sick IDM160 bar code scanner is connected to an XL200 series controller for the first time, the scanner must be setup to properly communicate with the controller before it can be used for data entry. Setup Procedure 1. Turn on the scanner. The scanner plays a musical tone, indicating it is on. 2. Verify that the Power Light on the solid Blue or Green. 3. Turn off the XL200 series controller, but leave the scanner turned on. 4. Scan the bar codes on the next pages in order (top to bottom). Do not proceed to the next bar code until you hear a beep confirming the scanner has read the bar code. 5. Once the bar codes are read, the setup is complete and the scanner is ready for operation. NOTE: This particular scanner does not have the capability of turning off the RTS/CTS (pin 7 and Pin 8) signal as described on page 1 of this document, therefore, pin 7 and Pin 8 of the DB9 Connector MUST be clipped or removed for proper operation of the scanner. See the troubleshooting section for more details. 4

Sick IDM161-300S Wireless Bar Code Scanner Setup Note: The following setup procedure works only with the Sick IDM161 bar code scanner. For other bar code scanners, please contact the manufacturer for proper setup procedures. When a Sick IDM161 bar code scanner is connected to an XL200 series controller for the first time, the scanner must be setup to properly communicate with the controller before it can be used for data entry. Setup Procedure 1. Turn on the scanner. The scanner plays a musical tone, indicating it is on. 2. Verify that the Power Light on the scanner base is solid Blue and the Status light is Off. If the power light is on continue to step 3. If the status light is on, this may indicate that the scanner needs to be paired with the base. This is done by following the directions on page 4 of the Sick Quick Start Guide that came with the scanner. This must be done before proceeding to the next step. 3. Turn off the XL200 series controller, but leave the scanner turned on. 4. Scan the bar codes on the next page in order (top to bottom). Do not proceed to the next bar code until you hear a beep confirming the scanner has read the bar code. 5. Once the bar codes are read, the setup is complete and the scanner is ready for operation. NOTE: This particular scanner does not have the capability of turning off the RTS/CTS (pin 7 and Pin 8) signal as described on page 1 of this document, therefore, pin 7 and Pin 8 of the DB9 Connector MUST be clipped or removed for proper operation of the scanner. See the troubleshooting section for more details. 5

Sick Scanner Setup Codes 6

Troubleshooting My Scanner Beeps but nothing shows up on the controller This is a common problem when setting up a scanner for the first time. The below steps will help you to located and identify the problem. In addition, if the controller is in Debugger mode when the scanner is plugged in then follow the steps below. You can check for this by touching Diagnostics/System Information and checking the RS232 port. If it says debugger the cabling or scanner is NOT configured properly!! Verify the proper cabling is being used. The bar code scanner CANNOT be directly plugged into the XL200 series controller. A NULL Modem serial cable must be used to interface between the 7

controller and the scanner. If you cannot locate a NULL modem cable, contact AMS Controls to purchase the Console Mounting Kit for your scanner. If you are using a Zebra LI3608 or Sick brand of scanner, you will need to make sure pin 7 and Pin 8 are not connected. This connection can be removed in several places, however, the easiest place would be on the serial cable or the gender changer. See the pic below: Verify the Scanner and the XL200 Controller share the same Ground. This can be verified by using a multimeter. Go through the scanner setting again! Follow the instructions closely! If none of the above items correct the problem call AMS! 8