Product manuals. Shanghai Shuncom Communication Technology Ltd. SZ05-ZBEE embedded wireless communication module.

Similar documents
ZIGBEE WIRELESS MODULE USER`S MANAUAL - 1 -

ETH to 232 (A) User Manual

ZLAN9500/03 Series. User Manual

SNR610. Embedded network node module SNR610. Description. Feature. Application. SNR610 is highly integrated network module.

Catalog 1. Overview Feature Application Block Diagram

Bluetooth TO Serial CONVERTER E-P132-B

ZigBee is a specification based on the IEEE standard for wireless personal area networks (WPANs).

Bluetooth to RS-232 Converter. RT-132B Bluetooth Adaptor Operation Manual

DRF1605H Zigbee Module 1.6km Transfer CC2530 Wireless Module UART to Zigbee

DRF1278DM LORA Long Range SX1278 Data Radio Modem V2.72

Zigbee Module User Guide

Bluetooth to RS-232&RS422/485. EX-9132B/BI Bluetooth Adapter Operation Manual

RC1170-RC232 USER MANUAL

Super Port User Guide Contents Serial to Ethernet converter(super Port) Introduction Overview Features Applications

Document Name : User Manual for SC10B : RS232 to Bluetooth Converter.

zigb232 & zigb485 User Guide User Guide TANGENT TECHNOLABS

ZigBee Converter User s Manual

DL-LN3X Series 2.4G Ad-hoc Network Wireless Communication Module

SST-2450 Wireless Modem User s Manual

NPort Z2150 User s Manual

RF900 LoRa Telemetry module V1.0

WIFI DEVICE. User Manual. Shanghai Shuncom Electronic Technology Co., Ltd. Shanghai Shuncom Electronic Technology Co.,Ltd.

QY-9263K Development Board Hardware Manual

[WIR-1286]868MHz LORA Wireless Module. Page 1. LORA 868MHz Wireless serial link [WIR-1286]

HAC-UNet manual SHENZHEN HAC TECHNOLOGY CO., LTD. HAC-UNet. 470MHz Micro Power Wireless Self-organized Module (Based on VBee protocol) V2.

BLE010V2 (CSR1010) Bluetooth Modules User s Manual

ZigBee----free as a bee!

USR-K1 Super Port. File version: V1.0.4

RN-174. WiFly GSX Super Module. Features. Description. Applications. rn-174-ds v1.1 3/3/2011

TX-5 LBS ANTI-THEFT ALERT SYSTEM (LBS+GSM+SMS/GPRS) Fast Installation Instruction & User Manual

RN-174. WiSnap M2 Super Module. Features. Description. Applications. ~ page 1 ~ rn-174-ds v1.1 6/1/2011

Industrial Serial Device Server

Embedded Modbus TCP Module GS11-MT. User Manual REV 1.1. SST Automation.

Wireless-Tag WT51822-S4AT

USR-GPRS-MODEM user manual

RN-174. WiFly GSX Super Module. Features. Description. Applications. rn-174-ds v1.1 4/20/2011

BM2001 (Bluetooth USB Adapter) User s Guide

Universal Serial/PROFIBUS DP Gateway GT200-DP-RS User Manual V6.1 SST Automation

RN-174 WiFly Super Module

RN-174. WiFly GSX Super Module. Features. Description. Applications. rn-174-ds v1.1 1/24/2011

深圳市鼎泰克电子有限公司. Zigbee Module User Guide. Shenzhen DTK Electronics Co., Ltd V5.7. Shenzhen DTK Electronics CO., LTD. Zigbee Module User Guide DRF Series

WIR-1386 / WIR-1186M Long Range 865MHz 867MHz RF Wireless Module with WIR-METERING Mesh Stack

LM058 Bluetooth Serial Adapter

ZLAN7104 High-Performance

BLE232: Manual Copyright 2014 taskit GmbH

Innovati s Bluetooth 100M Universal Wireless Bluetooth Module

ZLSN2002 Embedded Device Networking Module. User Manual

ECAN-240. (Modbus TCP to 2-port CAN Bus Gateway User manual) ECAN-240 Modbus TCP to 2-port CAN Bus Gateway User Manual, Version 1.0.

Z-0001 ZigBee Module Manual

NDB-C0706A Dual Mode Bluetooth Module

C500B-LCD Instructions

Declaration X-100 PAD

User s Manual Closer to Real, Zigbee Module ZIG-100. Wireless Communication. ROBOTIS CO.,LTD

Modbus/ PROFIBUS DP Gateway PM-160

Active RFID Reader User Manual

isma-b-mg-ip User Manual Global Control 5 Sp. z o.o. Poland, Warsaw

BM1001 & BM2001 Serial & USB Adaptor

+ (5~27 VDC) GND. Bluetooth V4.1 BLE RS-232 Serial Adapter. Model: BLE-232B. 1. Package content: BLE RS-232 adapter

15693-RW-TTL-PCB1 CONTENT 1. MAIN FEATURES PINNING INFORMATION BAUD RATE SETTING COMMUNICATION PROTOCOL...5

ICRM SER User s Guide

USER MANUAL HPS-120. About this product: Your Communications Solutions Provider

T1K MODBUS Base Controller Specifications

Overview. Applications. Features. Pin assignment

USR-TCP Hard version: V1.1 File version: V

RS485 MODBUS Module 8AO

User Manual. ESP8266 Wifi Shield

+ (5~27 VDC) GND. Bluetooth V4.2 BLE RS-232 Serial Adapter. Model: BLE-232D-E. 1. Package content: BLE RS-232 adapter

LM300 Bluetooth Ethernet Access Point/Server 3 Simultaneous Bluetooth SPP Connections

RC702-FX Ethernet over SDH User Manual

w w w. z i g s e n s e. c o m. a u

Queue Wireless Calling System User Manual

Sierra Radio Systems. Mesh Data Network. Reference Manual. Version 1.0

USR-TCP Hard version: V2.0 File version: V

BUENO ELECTRIC. SW-400T. 4 Port CAN Switch User Manual

Wireless Solutions. 5.1 Wireless LAN & Wireless Modem. Wireless Modems. Intelligent GPRS/GSM Modules. Mini-Programmable Automation Controllers

ACE PLUS CORP. APCON100 series Operation Manual RS-232 to Ethernet Converter

Chapter 5: Communications 5 1 SR55 Communications Overview 5 2

ZigBee Products Brochure

RN-134. WiFly GSX Super Module SuRF Board. Features. Description. Applications. ~ page 1 ~ rn-134-ds v1.

Model:UT-8814 USB/RS-232 Commercial interface converter. Instruction Manual

Bluetooth Serial Adapter

ZigBee TM - Measurement and Switch Socket. User Manual. Measurement and Switch Socket Model: Z809A. Firmware: V3.5 Hardware: V1.2

RN-WIFLY-EVAL-UM. WiFly Evaluation Kit Roving Networks. All rights reserved. RN-WIFLY-EVAL-UM-1.0 Version /8/2011 USER MANUAL

Bluetooth RS232 Serial Adapter

G0313 Modbus to FF Gateway User Manual

The I-7530A RS-232/485/422 to CAN Converter

APC Series Transparent Transceiver Module APC230-43

ZLAN5443A. User Manual

Low-Power-Radio Transceiver IC

Features : General Description:

Arduino UNO R3 ESP8266 Web Server Serial Port WiFi Shield ESP13

Dual Serial Shield User Manual

JDY-40 wireless serial port module

TRAINING GUIDE LEVEL 3 MODBUS WRITE IMPORT COMMAND

RC701/RC702-FE series Ethernet over SDH devices User Manual

3.1 I-7560 Pin Assignment and Specifications: Introduction

LM300 Bluetooth Ethernet Access Point/ Server 3 simultaneous Bluetooth SPP connections

bluetooth module Contents 1. Product s picture 2. Feature 3. Pins description 4. The parameters and mode of product 5.

SATEL I-LINK 100 MB I/O-converter User Guide, Version 1.1

TCF-142 Quick Installation Guide

Transcription:

Product manuals SZ05-ZBEE embedded wireless communication module Shanghai Shuncom Communication Technology Ltd. - 1 - Shanghai Shuncom Communication Technology Ltd.

Contents Ⅰ Introduction... 3 Ⅱ Technical ecifications... 错误! 未定义书签 Ⅲ Interface... 错误! 未定义书签 3.1 Module to the left of pin identification... 5 3.2 Module to the right of pin identification... 5 3.3 The module wiring diagram... 6 3.4 Module control lines... 8 3.5 Power interface... 8 3.6 Data interface... 9 3.7 Node type configuration... 错误! 未定义书签 3.8 Configuration interface... 错误! 未定义书签 Ⅳ Module configuration... 错误! 未定义书签 4.1 Communication channel set... 11 4.2 NET_TYPE network type... 11 4.3 NODE_TYPE device type... 12 4.4 The network number NET_ID Settings... 12 4.5 Data sent TX_TYPE mode Settings... 12 4.6 Equipment MAC_ADDR address... 13 4.7 DATA_TYPE data types... 13 4.8 DATA_BIT data set... 13 4.9 Serial BAUD_RATE baud rate... 14 4.10 DATA_PARITY calibration data set... 14 4.11 Serial TIME_OUT overtime... 14 4.12 SRC_ADDR address data set... 14 Ⅴ Data sending instructions... 15 5.1 Data sending model... 15 5.2 Data transmission frame format... 15 Ⅵ Installation of equipment... 15 6.1 Module installation dimensions... 15 6.2 Working instructions... 16 6.3 Cautions... 错误! 未定义书签 - 2 - Shanghai Shuncom Communication Technology Ltd.

Ⅰ Introduction The boat SZ05 series of embedded wireless communication module integrated ZigBee protocol standards radio frequency transceivers and microprocessors. It has the characteristics and advantages of long communication distance, strong anti-jamming capability, flexible network and stable performance. Meanwhile, it can achieve point-to-point, multipoint, multi-multipoint transparent data transfer between devices. And the devices communicate with each other forms the network of a star, a branching tree or a net (mesh). SZ05 series of wireless communication module s data interfaces including: TTL interface and RS232 standard interface. They can send the data by way of broadcast or target address. In addition to achieving the general point-to-point data communication functions, they also can realize the multipoint communication. What s more, the serial communication is so easy and convenient to use that it can reduce the matching process time of inserting the embedded module. SZ05 series of wireless communication module is divided into three nodes in the network: Central Coordinator, Router and End-Device. They have different functions in the network. The Central Coordinator is the central nodes which can automatically initiate maintain and manage the information of the network. The Router takes the charge of liking network together, transmitting the data and associating with other routers and End-devices. And the terminal nodes only send and receive the data. Central coordinator, a router and terminal node, these three types of devices are the same in hardware but the embedded software is different. In way of jumpers settings or software configuration can realize the different functions of devices. Ⅱ Technical specifications Category Index name SZ05 series wireless module The transmission distance 100 meters - 2,000 meters Wireless network Network topology Addressing mode Star, tree and chain type, mesh network IEEE802.15.4 / ZIGBEE standard address Network ID 255 Maximum data packet 256 bytes Data interface Data interface TTL, RS232 standard interface Serial signal TxD, RxD, GND - 3 - Shanghai Shuncom Communication Technology Ltd.

Serial rate 1,200 ~ 38,400 bps Serial calibration None, Even, Odd Data bits, 7, 8 parity 1 Modulation mode The DSSS direct sequence spread spectrum Frequency range 2.405GHz~ 2.480GHz transceiver Wireless channel 16 Receiving sensitivity -94 dbm Transmission power -27dBm~25dBm Antenna The outer SMA antenna or PCB antenna Conflict prevention GTS CSMA - CA and CSMA - CA Input voltage DC 5V Maximum current 70 ma power Maximum receiving current 55 ma Working environment Standby current Power saving mode Sleep pattern Working temperature Storage temperature 10 ma 110 ua 30 ua -40 C ~ 85 C -55 C ~ 125 C Ⅲ InterfaceSZ05-ZBEE 无线通信模块标准接口规范, 包含电源接口 数据 接口 控制接口和系统指示灯接口和天线接口等, 接口采用标准 2.54 双排插针, - 4 - Shanghai Shuncom Communication Technology Ltd.

与系统接口可以采用插座或接到用户系统 SZ05-ZIGBEEThe wireless communication module user manual 3.1 Module to the left of pin identification Sequence Mark Function Notes 1 GND Ground 2 +5V Power input is 5V 3 RX1/TTL TTL level input TX output to connect the user system 4 TX1/TTL TTL level output RX input to connect the user system 5 SGND Serial RS232 signal ground Ground 6 TX2/RS232 Serial RS232 output Connect the user input 232 7 RX2/RS232 Serial RS232 input Connect the user output 232-5 - Shanghai Shuncom Communication Technology Ltd.

8 System reserved Vacant 9 RESET System reset LOW Reset 3.2 Module to the right of pin identification Sequence Mark Function Notes 1 DATA Sending and receiving data instructions Low light. the data transceiver is flashing 2 RUN System running light Low light. interval of 1second flashes 3 NET Network indicators Low light. the center succeeded in building a network node, bright light from the node to connect the network 4 ALARM System warning light Low light 5 SLEEP Low power consumption 6 485CTL 485 transceiver control 7 CENTER Center node 8 DEVICE Terminal node 9 CONFIG Configuration interface Low access to low-power, high level or normal operation of floating Low output when the module 485 to receive. high output when it sent Low effective or adding the jumper cap becomes a central node. If 7 and 8 are as high level or floating it is the routing node. Low effective or adding the jumper cap into the terminal nodes. If 7 and 8 are as high or floating it is the routing node Low effective or adding the jumper cap into the system configuration state 3.3 Module wiring diagram - 6 - Shanghai Shuncom Communication Technology Ltd.

3.3V 1K LED User CPU control I/O DATA RUN NET ALARM SLEEP GND +5V RX1 TX1 SGND 5V TTL receive, connected user CPU TX TTL sends, connected user CPU RS232 Signal Ground 485 receive sends control User CPU control I/O User CPU control I/O User CPU control I/O 485CTL CENTER DEVICE CONFIG TX2 RX2 RESET RS232 sends,connected user 232 RX RS232 receive,connected user 232 TX Center node System reset control User system wiring one Wiring One: CPU control of the user system I / O port to control the function of all modules 3.3V 1K LED User CPU control I/O 485 receive sends control DATA RUN NET ALARM SLEEP 485CTL GND +5V RX1 TX1 SGND TX2 5V TTL receives, connected user CPU TTL sends, connected user CPU RS232 Signal Ground RS232 sends,connected user 232 RX Jumper shorted effective CENTER DEVICE RX2 RS232 receives,connected user 232 Center node CONFIG RESET System reset control User system wiring two Wiring Two: A short jumper connection to control the center node, relay routing node or the terminal node is set into CONFIG mode, if the short jumper was effective, central node or terminal node jumper selection can only be chosen one. If both of them are suspended, the node will be a relay routing node. The suspended state comes into work if CONFIG is set into the configuration state by a short jumper. - 7 - Shanghai Shuncom Communication Technology Ltd.

3.4 Module control lines Pin Module initialization Valid state User Control I / O initialization Control state DATA High level 3.3V Low level NET High level 3.3V Low level RUN High level 3.3V Low level ALARM High level 3.3V Low level SLEEP High level 3.3V High level 3.3V Low level 485CTL Low level Connect the 485 chips controller CENTER High level 3.3V Low level High level 3.3V Low level DEVICE High level 3.3V Low level High level 3.3V Low level CONFIG High level 3.3V Low level High level 3.3V Low level 3 seconds RESET High level 3.3V Low level High level 3.3V Low level 3.5 Power Interface The standard operating voltage of SZ05-ZBEE wireless communication module is DC-5V. The normal operating voltage range is from5v to 12V. Notes: The power of positive and negative can not be reversed. Otherwise they will burn out the module. 3.6 Data interface SZ05-ZBEE wireless communication module offers two standard interfaces: RS232 interface and TTL interface. The working interfaces of serial port RS232 are TX, RX and GND. However, the TTL working interfaces are TX and RX. And the TTL level is 3.3V. System default data interface parameters: - 8 - Shanghai Shuncom Communication Technology Ltd.

Serial port parameters Default Set Serial Rate 9,600 Serial check None Data bits 8 Stop bit 1 3.7 Node type configuration SZ05-ZBEE wireless communication module has three node types: center node, relay routing node and the terminal node. A short jumper connection is to control the center node, the relay routing node or the terminal node, if the short jumper is effective, the center node or the terminal node can be only chosen one. This node will be the relay routing node if the two short jumpers are suspended. 3.8 Configuration interface If CONFIG jumper shorted or external control line of SZ05-ZBEE wireless communication module gets into the low level state in 3 seconds, the system will come into the configuration state. Being high level or floating is the working state. Configuration interface is used for some parameters to be configured. The default configuration of Serial RS232 is as follows: Serial port parameters Default Set Serial Rate 38,400 Serial check None Data bits 8 Stop bit 1 Configuration interface settings The configuration mode of SZ05-ZBEE wireless communication module can be divided into super-terminal configuration mode and the computer network management configuration mode. The state of the two models is classified as follows: - 9 - Shanghai Shuncom Communication Technology Ltd.

Instructions state Instructions meaning Super- terminal configuration mode Data, operation, network and alarm light flicker at the same time Computer network management configuration mode Alarm light flashes in 1 second interval. Running lights flashes normally. Data light don t flicker. Super- terminal configuration mode means entering the computer s super terminal to do the module settings. Computer network management configuration model is the protocol specification which can provide the system interface for the user to carry on the software integration. The steps of the Super-terminal configuration mode 1.Open the computer's HyperTerminal and set HyperTerminal as follows: 38400 baud, 8 data bits, check NONE, stop bits 1, flow control none. 2. CONFIG jumper shorted or external control line comes into the low level. 3. Power to devices. 4. Entering the device configuration mode. Notes: Being the configuration mode, the serial port is configured: 38400 baud, 8 data bits, check NONE, stop bit 1. So the computer's serial port settings must be 38400 baud, 8 data bits, check NONE, stop bit 1, flow control NONE. Ⅳ Module configuration Equipment configuration options are as follows: Configuration options Chinese options Configuration The default parameters CHANNEL A communication 0x0F Use Netcom channel channel NET_TYPE Network type Mesh network NODE_TYPE Device type Relay route NET_ID Network ID Use Netcom number 0xFF TX_TYPE Sending mode radio MAC_ADDR Device address Different device has different address DATA_TYPE Data type HEX - 10 - Shanghai Shuncom Communication Technology Ltd.

DATA_BIT BAUD_RATE PARITY TIME_OUT SRC_ADDR Data bits, Baud rate Data validation Serial overtime Data source address 8 9,600 NONE 0x05 ms Not output 4.1 Communication channel set Channel Configuration instructions Notes 0-F 0 : 2.405GHz 1 : 2.410GHz 2 : 2.415GHz 3 : 2.420GHz 4 : 2.425GHz 5 : 2.430GHz 6 : 2.435GHz 7 : 2.440GHz 8 : 2.445GHz 9 : 2.450GHz A : 2.455GHz B : 2.460GHz C : 2.465GHz D : 2.470GHz E : 2.475GHz F : 2.480GHz Recommended 4, 9, 14 or 15 channels, which can avoid WIFI interference. G AUTO mode to choose the best channel 4.2 NET_TYPE network type NET_TYPE options Network type Configuration notes MESH Mesh network Master-slave network and the network must have STAR Star nets only one center node. In the same network, the network type must be set the same. - 11 - Shanghai Shuncom Communication Technology Ltd.

LINE_1 Chain type nets ID=1 LINE_2 Chain type nets ID=2 LINE_3 Chain type nets ID=3 LINE_4 PEER Chain type nets ID=4 Peer-to-peer network Master-slave network No center node 4.3 NODE_TYPE device type NODE_TYPE options Network types Configuration note PAN_COORD Center node ROUTER Relay route It has the terminal equipment functions, too. There must be a center node in the network. END_DEVICE Terminal equipment SZ05-ZBEE wireless communication module has three types: the center node, the relay routing node and the terminal node. A short jumper connection is to control the center node, the relay routing node or the terminal node, if the short jumper connection is effective, the center node or the terminal node can be only chosen one. This node will be the relay routing node if the two short jumpers are suspended. 4.4 The network number NET_ID Settings NODE_TYPE options ID range Configuration notes NET_ID 00 FF The whole network s ID must be the same. In a network, ENTER NET_ID # 2, then click "setup". ENTER the ENTER 4.5 Data sent TX_TYPE mode Settings TX_TYPE options Send mode Configuration notes - 12 - Shanghai Shuncom Communication Technology Ltd.

BROADCAST Broadcast mode No target address MASTER SLAVE Master-slave mode The center node must have target address. Non-central nodes haven t target address and default send the data to the center node. If target address is 2 bytes MAC address, it must be added before the packet. POINT POINT peer-to-peer Target address must 4.6 Equipment MAC_ADDR address MAC_ADDR options ID range Configuration note MAC_ADDR 0000 FFFE The address of center node is 0000 The whole network cannot have the same address nodes. Input the net 4 device address and then press "ENTER" to finish the setup. 4.7 DATA_TYPE data types DATA_TYPE options Data types Configuration ASCII HEX ASCII Hex It must be set if has the target address. If broadcast way without settings. 4.8 DATA_BIT set DATA_TYPE options Data types Configuration 7+1+1 7 bit data + 1 check + 1 stop bits 8+0+1 8 bit data +0 check + 1 stop bits To combine with data validation to set - 13 - Shanghai Shuncom Communication Technology Ltd.

8+1+1 8 bit data +1 check + 1 stop bits 4.9 Serial BAUD_RATE set BAUD_RATE options Baud rate range Configuration 1,200 38,400 1,200-3,8400 Choose match baud rate 4.10 DATA_PARITY set DATA_PARITY options Equipment types Configuration NONE No calibration EVEN Parity checking Select the match calibration type ODD Parity checking 4.11 Serial TIME_OUT set TIME_OUT options Equipment types notes TIME_OUT 1-255ms(Hexadecimal display) Serial overtime time. 4.12 SRC_ADDR data source address set SRC_ADR options Data source address Configuration NOT OUTPUT HEX Not output source address Hexadecimal output According to the application to choose whether to output source address of data packets - 14 - Shanghai Shuncom Communication Technology Ltd.

ASCII ASCII output The formats of Hexadecimal output source address: 2 bytes of data source address + valid data. The formats of ASCII mode output source address: 4 bytes of data source address +valid data. Ⅴ Data sending instructions 5.1 Data sending mode Module type Send mode Goal node Send mode Center node radio Master-slave or peer-to-peer All non-central node within the network Target address node Data directly Target address + data radio All non-central node Data directly Non-central node Master-slave Center node Data directly peer-to-peer Target address node Target address + data 5.2 Data transmission frame format Send mode Data coding Data frame format Data directly Target address + data Hexadecimal target address ASCII target address Do not make any changes 2 bytes target address + data 4 bytes target address + data Ⅵ Installation of equipment 6.1 Module installation dimensions - 15 - Shanghai Shuncom Communication Technology Ltd.

6.2 Working instructions Z05-ZBEE wireless communication module provides four working status LED indication interfaces which are data, network operating system transceiver, network state and alarm interface. The four lights instructions are as follows: - 16 - Shanghai Shuncom Communication Technology Ltd.

indicator Indication state Meaning of the indication Data, Light or extinguish Data receive or send once running Network, alarm Light in 1 second interval extinguish light extinguish extinguish light System runs normally System doesn t work or haven t connect the electricity or has something wrong with the system Center node successfully connects the network, and other nodes have joined the network Not connected network Work normally System abnormal or system was in a special state Special state of the system: Instructions Data, operation, network and alarm light flash disorderly or irregularly Data, operation, network and alarm light flash at the same time Alarm light flashes in 1 second intervals, running light flashes normally, and the data light doesn t flash Instruction meaning Initial system operation but without initial operation parameters System into the super terminal configuration mode System enters the configuration mode of computer network management 6.3 Cautions 1. The model does not have waterproof function. Please don't directly install the product in the outdoor and moist place, 2. This product is a wireless electronic product, please don't install it in the metallic shield shell and try to install in the open, no obstacles place. 3. This product is installed outdoor, if the surrounding is compare open, please install the lightning rod in case of lightning. - 17 - Shanghai Shuncom Communication Technology Ltd.