BACnet. b3867 Terminal Controllers

Similar documents
Andover ContinuumTM b3865/866 VAV Controllers with Built-in Actuator

Andover ContinuumTM. b3850 Series Terminal Controllers

Andover Continuum Infinet II i2865/866 VAV Controllers with Built-in Actuator

Andover ContinuumTM Infinet II

BACnet. b3810 Series Local Controllers

Andover ContinuumTM Infinet II

Andover ContinuumTM Infinet II

The Infinity TCX 865 programmable Infinet terminal controller is a unique, low-cost VAV box

Andover Continuum. Power Supplies with or without UPS

Andover ContinuumTM Infinet II

Andover ContinuumTM. Family of Controllers. BACnetTM

ACX Series. Access Controller for Ethernet

lighting control. Each controller switches up to 48 high voltage, 20-amp lighting circuits, using

using optional EMX 190 expansion modules), and makes access decisions based on its own distributed

Specification Sheet For electronically commutated motors

clarity 3 Programmable Controller

Siemens BACnet Programmable TEC Unit Vent Controller for Smoke Control

Siemens BACnet Programmable TEC Unit Conditioner (Fan Coil) Controller for Smoke Control

TAC I/NETTM 1284, 1280, Security Control Unit

Siemens BACnet Programmable TEC Unit Vent Controller

PEAK TM. PEAK TM controllers. Mid-Market BAS Smart equipment controllers. HVAC/R controllers

Datasheet. ECB-PTU Series. 1/14. BACnet B-ASC Powered Terminal Unit Programmable Controllers. Overview

Datasheet ECB /6. BACnet B-ASC 10-Point Programmable Controller. Overview

Siemens BACnet Programmable TEC Unit Conditioner (Fan Coil) Controller

ECB-300 Series BACnet B-AAC 18-Point Programmable Controllers

Siemens BACnet Programmable TEC Dual Duct Two Air Velocity Sensors Controller

Siemens BACnet Programmable TEC Unit Conditioner Controller

clarity 3 VAV Programmable Controller

FX Input/Output (I/O) Modules XM07 and XM14

FX-PCX Expansion Input/Output Modules Catalog Page Code No. LIT Issued April 17, 2015

Installation Instructions for UL Rev A

Siemens BACnet Programmable TEC Dual Duct Two Air Velocity Sensors Controller

Siemens BACnet Programmable TEC Constant Volume

TC Modular Series for BACnet Networks

Datasheet ECB /6. BACnet B-ASC 10-Point Programmable Controller. Overview

TALON Network Manager- 2 & 6 Express

FEC - FAC. Metasys controllers. Complex BAS Programmable controllers. Catalog Page. Field Equipment Controllers

BACnet B-ASC Powered Terminal Unit Programmable Controllers. Overview

Datasheet. ECB-600 and ECx-400 Series. ECB-600 & ECx-400. Overview. Applications. Features & Benefits.

SE7600E Series Application Guide

BACnet Controller for General-purpose Building Applications

Web server. Simplified.

AIR HANDLING UNIT CONTROLS

Siemens BACnet Programmable TEC VAV with Series Fan and 3-Stage Electric Heat Controller

PXC Modular Series. Features. Description. Technical Specification Sheet Document No Rev. 1.1, May 2007

The Simply Smart Way to Optimize Building Control and Performance

TAC Xenta 121-FC Programmable Fan Coil Application

TAC Xenta 121-HP Programmable Heat Pump Application

LX Series Free Programmable Controllers

SEZ7000 Series. Wireless Commercial Zoning System

Input/Output Module (IOM) Series Catalog Page

FX06 Field Controller

Andover ContinuumTM. Family of Security Products

TC-9102 Terminal Controller

Smart Equipment Controls (SEC)

TC Compact Series Unitary Equipment Controller

Andover Continuum. Family of Security Products

TAC Xenta 101-VF. 3-Speed Fan Coil Controller. TAC Xenta

Datasheet. ECB-300 Series. 1/6. BACnet B-AAC 18-Point Programmable Controllers. Overview

Siemens BACnet VAV Actuator

TC Modular Series. Features. Description. Technical Specification Sheet Document No Rev. 1, July 31, 2008

TX-I/O Product Range. Description. Technical Specification Sheet Document No July 18, 2013

ECB-203 Series BACnet B-ASC 14-Point Programmable Controllers

PXC Modular Series. Features. Description. Technical Specification Sheet Document No July 24, 2012

Compact Series Unitary Equipment Controller

TC Compact Series for BACnet Networks

BACnet Terminal Box (VAV) Controller

ECB-VAVS. Features and Benefits. Applications Cooling Only VAV Boxes Cooling with Reheat VAV Boxes Room Pressurization.

Advanced Application Field Equipment Controller (FAC) Catalog Page

Building Energy Management Training Systems

XT-9100 Technical Bulletin

TAC Xenta 301. Controller, Freely Programmable

Suitable for a wide range of installations with wall-mount, flush-mount and hand-held remote control options.

SE7600E Series Application Guide

PM174 PM174 IEEE1159 ADVANCED POWER QUALITY ANALYZER. Features

Field selectable application type and room module series, via dip-switches on controller

Tracer Controls. Tracer ZN517 Unitary Controller BAS-PRC012-EN

Input/Output Module (IOM) Series Controllers Catalog Page Code No. LIT Issued June 2018

TC Compact Series for BACnet Networks

Viconics VT76x6W Water-source Heat Pump Controllers Engineering Guide Specification

Tracer Controls. Tracer MP501 Controller BAS-PRC008-EN. January 2005

Technical data sheet. PowerLogic power-monitoring units EM3500 series DIN Rail meter

FCU-4 FAN COIL CONTROLLER

ECB-VAVS and ECB-VAV Series

DS October MAXIM 1010 Controller

HARDWARE GUIDE. Water Loop Controller C1000 Series. Specifications and Operational Guide

DX-9100 Digital Controller, Version 2

Product Catalog. Tracer Controller MP501 BAS-PRC008-EN. May 2012

BACnet MS/TP Gateways for Mega Controls Modbus RTU Networking Devices

Room Controllers. SC3000 Relay Pack

Web server. Simplified.

VZ7000 Series. BACnet Commercial Zoning System

LDALI ME204-U, LDALI ME201 U

SORDS ELECTRIC ~ MA7200. Sensorless Vector AC Inverter.

isma-b-fcu FCU Hardware User Manual Global Control 5 Sp. z o.o. Warsaw, Poland

8 channel universal input and 4 channel Form C digital output

Product Catalog. Tracer Controls Tracer ZN517 Unitary Control BAS-PRC012-EN. August 2010

PXC Modular Series for BACnet Networks

SmartStruxure SmartStruxure Lite ZENO InnPoint. ZENOcontrols.com. compatible with

Datasheet. ECB-203 Series. 1/6. BACnet B-ASC 14-Point Programmable Controllers. Overview

Transcription:

BACnet b3867 Terminal Controllers The Andover Continuum TM b3867 is a native BACnet controller that communicates on an RS-485 field bus as a Master device using the MS/TP BACnet protocol.

02 Features Product AT A GLANCE Native BACnet MS/TP Communications for Interoperability to Third-Party Systems Supports 18 BACnet Object Types including Trends, Schedules, Calendars, and Loops Compact Terminal Controller Provides Low-cost DDC Control of Package Units,Heat Pumps, Unit Ventilators Universal with Form A, Form K, and Analog Outputs for Flexible Control Options Non-Volatile Flash Memory Provides Utmost Reliability Stores Both Application Program and Operating System Flash Memory Allows Easy On-Line Software Updates Local Extended Storage of Log Data On-Board Service Port Modular, Sleek Design SimplifiesInstallation in Small Areas View and Modify Information with Optional Andover Smart Sensor Display BTL Listed B-AAC Controller with Local Trends The b3867 provides cost-effective DDC control of package units, heat pumps, unit ventilators, and other terminal unit applications. Its versatile mix of I/O Universal inputs, Triac outputs, plus an interface to Andover s Continuum Smart Sensor room temperature sensor with programmable keypad allows for flexible control solutions. The b3867 also features two analog outputs to control reheat valves, dampers, lighting ballasts, etc. And because the b3867 is enclosed in a sleek, modular casing, it can be mounted in a small area perfect for retrofit applications. The b3867 features Flash memory, increased user memory, and a fast (32-bit) processor for faster scan times, with plenty of additional memory available for data logging of your critical data. As a native BACnet controller, the b3867 can communicate with other BACnet devices on the MS/TP network, in strict accordance with ANSI/ ASHRAE standard 135-2004, and are listed with the BACnet Testing Labs (BTL) as BACnet Advanced Application Controllers. (B-AAC). By connection to the Andover Continuum b4920 or bcx1 controller, the b3867 s and other MS/TP devices can share and gather data from the wider Ethernet/IP network of controllers. Among those Ethernet controllers can be Andover Continuum controllers (BACnet or Andover Continuum Infinet) or third-party BACnet/IP devices. All Andover Continuum devices, both BACnet and Andover Continuum Infinet, are fully compatible with the Andover Continuum CyberStation front-end software, a fully native BACnet Operator Workstation (B-OWS) application. Increased Reliability with Flash Memory The b3867 s non-volatile Flash memory stores your operating system and application programs, so that in the event of a power loss, your application will be restored when power is returned. In additon, the Flash memory allows for easy upgrades of your operating system via software downloads, eliminating the need to swap out proms. The b3867 includes an on-board battery to safeguard your runtime data protecting all point data and log data from being lost if power is removed.

03 Features (continued) The input configuration on the b3867 consists of four full range Universal inputs that accept voltage (0-5VDC), digital (on/off), counter signals (up to 4Hz), or temperature signals. The b3867 also offers a fifth input to support the Andover Smart Sensor, or any standard room temperature sensor. Dimensional Drawings 2 1 Outputs The b3867 contains five Form A Triac-based outputs. Each Triac is ground referenced. These outputs can be used separately for on/off or pulsed control of lighting, heat, and fan units or be configured into Form K Tri-state outputs (2-max) for bi-directional control of dampers and valves, with a free Triac output remaining. (Note: Any two consecutive Triac outputs can be configured as a Form K output.) Outputs are rated for AC loads only. The b3867 also offers two (0-10V) analog outputs. Software Capabilities The dynamic memory of the b3867 can be allocated for any combination of programs, scheduling, alarming, and data logging using the powerful Andover Plain English programming language. Our object-oriented Plain English language with intuitive keywords provides an easy method to tailor the controller to meet your exact requirements. Programs are entered into the b3867 using the Andover Continuum CyberStation TM. Programs are then stored and executed by the b3867. Programming multiple b3867s is inherently easy with Plain English. A complete copy of one b3867 s programs can be loaded directly into other b3867s without changing any point names or programs. 1 Power and Communications Drawing 2 24VAC 0.17A, 4VA 50/60HZ RS-485 PORT 5 4 3 2 1 L SHLD + - IN1 IN2 IN3 IN4 RET 1 2 3 4 5 UNIVERSAL INPUTS Drawing 3 Smart Sensor Interface The b3867 provides a built-in connection for Andover Continuum Smart Sensor. The Smart Sensor provides a 2-character LED display and a 6-button programmable keypad that enables operators and occupants to change setpoints, balance VAV boxes, monitor occupancy status, and turn equipment on and off. An enhanced version of the Smart Sensor is also available with a 4-digit custom LCD that provides the following icons: PM, %,, Setpoint, Cool, Heat, CFM, Fan, OA, and SP. 3 Outputs/Smart Sensor Drawing

04 Specifications b3867 Terminal Controllers Electrical Power 24 VAC, +10% -15%, 50/60 Hz Power Consumption 4 VA Overload Protection Fused with 2 amp fuse. MOV protected Software Real-Time Clock Synchronized through MS/TP Mechanical Operating Environment 32 120 F (0 49 C), 10 95% RH (non-condensing) Size 6.20 H x 3.50 W x 2.50 D (157H x 89W x 64) mm Weight 0.64 lbs. (0.29 kg) Enclosure Type UL Open class, IP 10. Flammability rating of UL94-5V Battery Battery Backup Replaceable, non-rechargeable, lithium battery. Provides 5 years typical accumulated power failure backup of RAM memory. Communications Communications Interface RS-485, BACnet MS/TP Communications Speed 9600, 19.2K, 38.4K, 76.8K baud Bus Length 4,000 ft. (1,220m) standard; Andover Continuum Infinet repeater module allows extension to longer distances. Bus Media Twisted, shielded pair, low capacitance cable Andover Continuum Infinet Device Profile Advanced Application Controller BTL Listed B-AAC with Local Trends /Outputs 4 Universal inputs: Voltage (0-5.115 VDC); Temperature -30 F to 230 F (-34 C to 110 C), Digital (on/off), Counter (up to 4Hz at 50% duty cycle, 125 ms min. pulse width). Current input (0-20 ma) using external 250 ohm resistor 1 Smart Sensor Temperature Input (32 F to 105 F) (0 C to 41 C) Input Voltage Range 0-5.115 volts DC Input Impedance 10K ohm to 5.120V or 5M ohm with pull-up resistor disabled Input Protection 24 VAC or 24 VDC temporarily on any single channel, ±1000V transients (Tested according to EN61000-4-4) Input Resolution 5.0 mv Input Accuracy ±15mV (±0.56 C from -23 C to +66 C or ±1 F from -10 F to +150 F) Outputs 5 single pole single throw (SPST) Form A Triacs (Any two consecutive outputs can be configured as one Tri-State Form K). 2 analog outputs (0-10V) Output Rating For SPST: Maximum 0.5A, 24VAC, ±2000V transients (Tested according to EN61000-4-4) Minimum: 20 ma AC Each Triac is ground referenced, DC loads not permitted. For 0-10V: 5 ma maximum, 2K ohm minimum impedance, ±1000V transients (Tested according to EN61000-4-4) Output Accuracy For SPST: 0.1 sec. for pulse width modulation For 0-10V: 50 mv resolution/100mv accuracy

05 Specifications (continued) b3867 Terminal Controllers Connections Power/Communications 5-position removeable screw 5-position removeable screw Outputs/Smart Sensor 16-position removeable screw Service Port 4-position shrouded connector Uwer LEDs/Switches Status Indicator LEDs CPU CPU Active TD Transmit Data RD Receive Data Switches RESET Input Pull-up Resistor Switch (per input) General Memory 128K SRAM, 1MB FLASH Processor Motorola 32-bit Coldfire Agency Listings UL/CUL 916, FCC CFR 47 Part 15, ICES-003, EN55022, AS/NZS 3548, and VCCI Class A, CE Options UL864, Smoke Control System Equipment, UUKL (i2867-s) Wireless BACnet b3867 version (b3867-wl) All brand names, trademarks and registered trademarks are the property of their respective owners. Information contained within this document is subject to change without notice. On October 1st, 2009, TAC became the Buildings Business of its parent company Schneider Electric. This document reflects the visual identity of Schneider Electric, however there remains references to TAC as a corporate brand in the body copy. As each document is updated, the body copy will be changed to reflect appropriate corporate brand changes. 2007-2009 Schneider Electric. All rights reserved. August 2007 pdw