www.eaton.com EATON Module Quick Start Standard Features When used with standard system, EATON Module provides isolated and Step-down 0/08/0 V AC outputs. Multiple Output receptacles: 0/08/0 V AC.
86-86000-0 B0 - Page
www.eaton.com STEP EATON Module Unpacking and Parts Check EATON Module Box Contents EATON Quick Start Manual Warranty and Product Registration Tower Stand Extenders EX RT 5/7/ Systems Quick Start Stabilizer Bracket ( screws included) Cable Rail Kit 60 mm / inch STEP EATON Module Tower Configuration (with EX RT only) Tower Configuration of Standard System with Module Module 5 E X B R T E X R T Battery Module Module Battery Module (up to 6) 86-86000-0 B0 - Page
E X R T E X R T STEP Rack Configuration See EX RT 5/7/ or 90 UPS Systems Installation and User Manual for details. A. Prepare the power module front panel logo and LCD display for rack orientation. Apply to all modules ( shown). Stack-up sequence in Rack configuration EX RT UPS 90 UPS E X R T EX RT FINISHED PANEL (rack orientation) E X R T (Shown with power module and battery modules). EATON Module (Top). POWER MODULE (upper, EX RT 5/7/). BATTERY MODULE (lower, EX RT EXB 5/7/). BATTERY MODULE (bottom, EX RT EXB 5/7/). EATON Module (Top). 90 UPS. EBM. EBM B. EATON Rack Installation 5. Attach both front mounting ear brackets to module with supplied screws. (For this step, it is possible to adjust the position of both front mounting brackets.). Attach rear support brackets to module. These brackets prevent the module from sliding out of the rack.. Attach rails together and secure with wing nuts, and finger tighten. (both sides).. Attach both rails to rear and front of rack with supplied flathead screws (as shown). 5. Use caution when sliding unit into rack. Temporarily secure unit to rack with thumb screws on front mounting brackets. 6. Secure rear support brackets to rails. 6 6 6 6 86-86000-0 B0 - Page
STEP Setup and installation Rear Panel of the optional Module Load : NEMA L6-0R, 08 Vac Load : NEMA 5-5/0R, 0 Vac Load : NEMA 5-5/0R, 0 Vac Load Circuit Breaker Load Circuit Breaker Load Circuit Breaker AC Input Main Output Circuit Breaker I/O Box AC Output Load Circuit Breaker Protect Breaker Load : NEMA L6-0R, 08 Vac Simplified Connection Diagram AC INPUT UPSTREAM CIRCUIT BREAKER (NOT SUPPLIED) Bypass AC Normal AC Module To Load Electrical Characteristics Nominal power kva Nominal current 6 A Input voltage 08-0 Vac Output Voltage 0/08/0 Vac Frequency 50/60 Hz ±0 %) Isolation (EN 6558---).75 kv / 5 M ohms Operating temperature From 0 to +0 C Max. operating rel. humidity 95 % Derating/altitude Pn-0 % > 000 m 86-86000-0 B0 - Page 5
STEP 5 Systems Connections with EX RT UPS EATON Module,, and Battery Module Connections System Connections with Module Battery Detection Cable Battery Module EX RT EXB 5/7/ EX RT 5/7/ Battery Power Cable Connector Battery Module Circuit Breaker EATON Module Main Output Circuit Breaker Follow connection diagram for appropriate input/output voltages. AC Normal INPUT. Check that the battery circuit breaker is OFF ( 0 ) position. Circuit Breaker OUTPUT TO LOAD L L L Lb Ld N Lc La. Connect the battery power cable to the connectors of the power and battery modules,. Connect the battery detection cable between connectors of the power and battery modules.. Turn on battery module circuit breaker, power module, I/O Box, circuit breaker, and Module Main Output Circuit Breaker. 5. Push ON button on the for more than seconds. AC Input from (08 VAC shown) AC Output to Load (0 VAC shown) Module I/O Box WARNING To avoid overloading 0 VAC output windings, distribute loads evenly between Load and Load (on rear of Module) and between 0 VAC output terminals (Lb-N, La-N.) Connection Diagram (bottom of I/O Box) L L L Lb Ld N Lc La 08 Vac 0 Vac 0 Vac 0 Vac 08 Vac 0 Vac Module Terminal block capacity: maximum AWG solid or stranded wire on transformer module. AC Input AC Output See EX RT 5/7/ Systems Installation and User Manual for initial start-up procedures. 86-86000-0 B0 - Page 6
STEP 6 Systems Connections with 90 UPS EATON Module, 90 UPS, EBM connections System Connections with 90 UPS EATON Module Main Output Circuit Breaker Follow connection diagram for appropriate input/output voltages. OUTPUT TO LOAD EBM Battery Connector () 0 A/50 V Output Circuit Breakers () C9 Output Receptacles Input Terminal Block Cover () C Output Receptacles Ground Bonding Screw Output Terminal Block Cover. Check that battery breaker is on OFF position.. Connect the battery cable between EBM and UPS,. Connect power cables to the UPS and transformer module.. Turn on battery module circuit breaker, UPS output circuit breakers, transformer module main Output Circuit Breaker. 5. Start UPS. Connection Diagram (right of I/O Box) L L L Lb Ld N Lc La 08 Vac 0 Vac 0 Vac 0 Vac 08 Vac 0 Vac Module Terminal block capacity: maximum AWG solid or stranded wire on transformer module. AC Input AC Output See 90 UPS Installation and User Manual for initial start-up procedures. 86-86000-0 B0 - Page 7