Single Loop Controller YS1000 Series

Similar documents
Single Loop Controller YS1000 Series

General Specifications

Nuclear Solutions. Data Acquisition, Control, and Monitoring Solutions for Nuclear Power. Bulletin 04L70B01-02E-A

Compact Controller M<CC-M>

General Specifications

General Specifications

Compact Controller M CC-M

General Specifications

Compact data logger offering best-in-class noise resistance and communication function

Eurotherm advanced controllers providing solutions for simple to demanding applications...

Technical Information

MPI-DN, MPI-D MULTICHANNEL ELECTRONIC RECORDER for HART or RS-485/ MODBUS RTU SENSORS

Instruction Manual. Model US1000 Digital Indicating Controller. IM 5D1A01-01E 3rd Edition IM 5D1A01-01E

SLC RetroPAK Controllers

/8 DIN Universal Process Indicator

General information. Display. Supply voltage. Input current

PXR Series Advanced Self-Tuning Temperature and Process Controllers

General information. Display. Supply voltage. Input current

Master Panel. Specifications. Document No. TS-2010 February 15, Product Description. Sample Specification

General information. Display. Supply voltage. Input current

General information. Display. Supply voltage

Trident and Trident X2 Digital Process and Temperature Panel Meter

353 RetroPAK Controllers

General information. Display. Supply voltage

General information. Display. Supply voltage. Input current

General information. Display. Supply voltage

VR18 FAQs - Frequently Asked Questions

Yokogawa YS100 Driver PTC Inc. All Rights Reserved.

General Specifications

Yokogawa YS100 Serial Driver Help Kepware Technologies

TABLE OF CONTENTS INTRODUCTION. 3. Analog Input Analog Output Digital Input Digital Output OPERATIONAL DESCRIPITON.. 7 PROGRAMMING AND INITIAL SETUP.

Data Sheet T 6493 EN. TROVIS 6400 Automation System TROVIS 6493 Compact Controller. For panel mounting (front frame 48 x 96 mm/1.89 x 3.

General information. Display. Supply voltage. Input current

DIGITAL CONTROLLER Multi-Loop. smar

General information. Display. Supply voltage. Input current. Encoder supply. Output current

General information. Display. Supply voltage. Input current. Encoder supply. Output current

Explosion-Proof Gauge Pressure Transmitter

LAUREL ELECTRONICS, INC.

Redundant System Redundant System P9-1-1

General information. Display. Supply voltage. Input current. Encoder supply. Output current

General information. Display. Supply voltage. Input current. Encoder supply. Output current. Power loss. Memory

SX 6000 Paperless Recorder

MODCELL 2050R Single Loop Controllers

DIGITAL INDICATING CONTROLLER

1/32-DIN TEMPERATURE CONTROLLER INSTALLATION, WIRING AND OPERATION MANUAL FORM 3882

Paperless Recorder VGR-B100. Series

General information. Display. Supply voltage. Input current

Omega and Red Lion team-up!

SX90 Process Controller

General information. Display. Supply voltage. Input current. Encoder supply. Output current

ABB Instrumentation. Specifications. COMMANDER 505 Advanced Process Controller

General Specifications

General information. Display. Supply voltage. Input current. Encoder supply. Output current

12-36 VDC/12-24 VAC Power Option 4-Digit Display, 0.56 (14.2 mm) or 1.20 (30.5 mm)

General Specifications

- SELF-TUNING PID ALGORITHM - INTUITIVE COLOR DISPLAY WITH TEXT MESSAGING - UNIVERSAL PROCESS AND TC/RTD INPUTS - MULTI- FUNCTION RAMP- DWELL/PROCESS

BMS Steam Station Solutions

FEATURES DESCRIPTION FEATURES

FloBoss TM 107/107E Flow Manager Overview

Self-Powered Wireless Instrumentation

LAUREL. Laureate Pulse or Analog Input Batch Controller Automatic batch control for repetitive liquid fill operations ELECTRONICS, INC.

General information. Display. Supply voltage. Input current. Encoder supply. Output current

Wall-/Pipe Mounted Universal Process Indicator

General Specifications

General Specifications

General information. Supply voltage. Input current. Encoder supply. Power loss. Memory

General information. Display. Supply voltage. Input current. Encoder supply. Output current

General information Engineering with Programming package. Display with display. Supply voltage 24 V DC Yes

eztrend QXe eztrend QXe Features Typical Applications Description Representative photograph, actual product appearance may vary.

MODEL: SC100. Single Loop Controller Series. MULTI-FUNCTION PID CONTROLLER (color LCD with touch-panel) MODEL: SC100 [1]0 [2][3]

General information. Display. Supply voltage. Input current. Encoder supply. Output current

/8 DIN Motorized Valve Controller

General Specifications

General information. Display. Supply voltage. Input current. Encoder supply. Power losses

XT-9100 Technical Bulletin

General Specifications

INSTRUCTION MANUAL STATION CONTROLLER SC1000 MOTOR PROTECTION ELECTRONICS, INC.

General information Engineering with Programming package. Display with display. Supply voltage 24 V DC Yes. Input current

Display. Supply voltage. Input current. Encoder supply. Output current. Power losses. Memory

INTRINSICALLY SAFE INSTRUMENTATION FOR HAZARDOUS AREAS

Yokogawa Y-Flow Master Database 62102

General Specifications

Display. Supply voltage. Input current. Encoder supply. Output current. Power losses. Memory

EnerSure Installation Guide

DUAL-LINE TEMPERATURE METER

deltadue series DIN rail mounting modules for control and data acquisition

Y800 Plus Frequency, Rate & Period Meter With dual, independently field-scalable channels

PBSCONTROL. AMS-R4000 Modular RTU. Remote Terminal Unit

EE360. High-End Moisture in Oil Transmitter. Typical applications. Features EE360 EE360. (+34)

General information. Display. Supply voltage. Input current

SystempaK (Digital/File Type) Dual Input Arithmetic Relay Module Model J-SCM 92/97

MID approval no. DE-08-MI004-PTB004 Date of release

MRC 7000 Proven Recording Reliability that Became the Industry Standard!

NF770 Temperature Compensation Liquid Flow Computer

General Specifications

DECS-250 Digital Excitation Control System

Saved Data playback Saved data in Memory card can be easily called out and played back on display

General Specifications

YS1000 Series Communication Interface User's Manual

ControlMaster CM30 Universal process controller, 1 /4 DIN. Making process control easy

Transcription:

Single Loop Controller YS Series Single Loop Controller Bulletin B8A-E www.ys.com

Easy to use Color LCD display with a wide variety of screens Designed with a lightweight, compact case. Programs using text language or graphical High reliability Dual CPU s Built-in hard manual CE and FM Class I Div II approvals A YS beyond... Powerful and Flexible * Ethernet ready (MODBUS TCP) Supports MODBUS RTU serial Available peer to peer and DCS communication options Extended I/O option available Compatibility Envision a plant... IP The new YS series of single-loop controllers is the successor to the Yokogawa YS and YS8 single loop controllers. The YS series offers improved connectivity with supervisory systems and incorporates new, enhanced features that help operators work more efficiently. The YS will work efficiently in petrochemical, chemical, power, pulp and paper, boiler and combustion control applications. with mm cutout Easy upgrade for YS Replacement housings for YS and YS8 controllers Excellent replacement for obsolete competitive controllers * Some of functions are available as optional features or available to a specific model. Please see model and suffix codes for ordering information. YS Series is a core building block of Yokogawa's VigilantPlant solutions that promise to bring operational excellence. 3

Easy to use Functions that support process operations Color LCD that s easy to see and easier to use. Main display Digital values displayed side-by-side with an intuitive analog meter makes the YS the perfect replacement for YS8 or obsolete moving coil controllers. Event Display Displays when events are occurring. messages can be displayed in English, Chinese, Japanese and other languages. TREND Display Your selection of up to analog inputs or outputs can be displayed as trends. ALARM Display Color LCD alarm display makes it easy to identify and review alarm activity. Single-loop controller LOOP Display Loops color-coded for easy identification DUAL Display Ideal for -element control such as cascade or selector control Features a half-reflecting LCD Maintains good visibility, even on panels subject to direct morning and evening sunlight. Under indoor fluorescent lighting Exposure to Sunlight Note: Avoid constant exposure to sunlight as this can shorten the lifespan of the LCD display. Designed with a lightweight, compact case YS mm,.kg YS 3mm, 3.kg YS8 8mm, kg YS8 YS YS Provides for greater freedom of instrumentation design Compact, lightweight design allows the use of smaller and less expensive panel. Moreover, it allows attachment to doors which was previously difficult.

Reduction of engineering costs YS Configuration and Programming Software Your Choice of Programming Style: Graphical or Text Based New Graphic Programming Tool Original Text Based Programming Supports on-line module monitoring function Program capacity Supports Blocks YS Backwards compatible with existing programs. Conversion software for existing YS user programs is available(*). Program capacity Supports steps.. times of the previous YS. SLPC Backwards compatible with existing programs. Conversion tool for importing programs from YS8 SLPC ROM is available(*). Programming is easier with our intuitive function block programming. The online module monitoring function allows you to confirm the performance while programming. Backwards compatible with existing YS users programs. Increased programming capacity allows you to create more sophisitated control schemes. Three connection modes Connection modes: USB, Ethernet or RS8 When connecting via RS8 or Ethernet, a communication option is required on the main unit. Configuration and Programming Software YSS Ethernet communications Dedicated USB cable RS8 communication Full set of computation functions Supports parameter setting for all YS models Support for YS custom programming. - Calculations done using Engineering units and Floating point math. - Includes over one-hundred computation modules for exponents, logarithms, temperature/pressure correction, and other operations. - Function blocks (sub-programs) can be saved and reused.* Password protection function Passwords can be assigned to user programs to prevent unauthorized access to proprietary programs. A password on the main unit prevents unexpected changes in the engineering parameters. Calibration tool* Following the YSS s online calibration instructions makes calibration easy. Calibration records and data can be saved on the YS, allowing you to load or print past calibration data as needed. *: under development. Inquire for release/shipping dates.

High reliability Improved process up time Control output backup function Battery free memory backup The control output backup function comes standard with YS series controllers (YS and YS) and the Manual Station for MV Setting (YS3). Nonvolatile memory is used for memory backup. Service life is improved because no batteries, backup capacitors, or other components are used. Dual CPU MV operation Display signal Key operation Display CPU Control Circuit D/A converter A/D converter MV MV Display CPU's process at normal condition Main CPU's process at normal condition Back-up process at fail Main CPU Output Circuit Hard Manual With dual-cpu construction (main CPU and display CPU), manual control capability and display continues even if an abnormality occurs on one of the CPUs. If controller self-diagnostics detects a control circuit failure, the controller can suspend analog/digital output, switch to manual mode and allow manual control by operator. MV Improved basic control performance The YS series achieves higher performance than previous models (YS series). I/O accuracy Voltage input accuracy: ±.% ±.% Voltage output accuracy: ±.3% ±.% Current output accuracy: ±.% ±.% Internal data resolution of the I/O signal: / / Internal computation resolution of PID and other computations: /9 /3 AC/DC power supply resists powerline fluctuations. The AC/DC (V/V) power supply powers the instrument to provide consistent performance.also accepts DC power regardless of polarity (specify V power supply when ordering). Controller online replacement function (portable manual station) Failure area Functions Control with Hard manual Manual operation with front keys Main CPU fail Display CPU fail All CPU and Control Circuit Use the YS portable manual station when exchanging or performing maintenance on a controller. You can switch to the spare controller without interrupting the control output. Display for and Control algorithm stop stop stop Manual operation Hard manual Front Panel Hard manual comes standard with the YS, YS, and YS3. Manual operation is possible even if all CPUs and control circuits are in a fail state. YS, YS Controller YS Portable manual station Hard manual operation wheel Front panel conforms to the IP waterproof standard Independent manual override is built into the control circuits, ensuring that control output can continue even when a control circuit including the CPU experiences a problem.

Powerful and Flexible System connectivity functions Ethernet support The instrument can be easily connected to DAQWORX, DAQSTATION, general-purpose SCADA, and OPC servers via Ethernet (Modbus/TCP). Ethernet (Modbus/TCP) Ethernet (Modbus/TCP) DX/DX Additional I/O can be added by selecting the YS basic model (with ). The total number of input/outputs points with the main unit and are 8 analog inputs, analog outputs, and DI/DO. External AI: 3 inputs External AO: outputs External DI: points External DO: points Note: An interface for the additional cannot be added after delivery. If there is a possibility that extra input/outputs will be needed, we recommend that you start with the basic model (with expansion I/O). Ethernet : Available to the YS basic type. Modbus/TCP server function (one connection). with PLC Connections are enabled using the FA-M3 s UT link module and the RS8 communication function. No programming is necessary to exchange data between the instrument and the FA-M3. with CENTUM As with previous models, communication with Yokogawa s DCS (CENTUM) is supported. This is ideal for DCS backup in chemical plants and other applications requiring extreamly high reliability. Applicable Models: YS, YS, YS3, and YS3 FA-M3 CENTUM (CS/3) HIS Modbus RS8 FCS FCU Control bus ALR RS8 YS YS YS The YS can also be connected to PLCs of various manufacturers via the Modbus communication protocol. Peer-to-peer communication function YS YS YS3 YS3 A sample of System Construction With peer-to-peer communication, up to 3 YS can be connected interchangeably. Four of the connected instruments can each output points of analog data and points of status data. This makes data exchange and I/O sharing possible since all instruments under peer-to-peer communications can read all data ( analog and status data). This is optimal for multi-loop control as such with boiler instrumentation. I/O sharing Data sharing RS8 Field instruments Inter-lock system YS3 Upper system YS Note: Does not support the YS series peer-to-peer communication network (YS-net). YS Maximum no. of connections : 3 No. of receiving units : 3 No. of transmitting units : Transmitted data : analog and status data per transmitting YS interval : ms average (not synchronized to the control computation interval) YS3 YS3 Field wiring Signal in the panel

TAGTAGTAG MV 3. % ALARM STC-ON C. STC ON. C O C Compatibility Total cost reduction Cases and housing for replacing old models Indispensable for lasting, stable operations at the plant when replacing instrumentation. Case and housing are available for replacement of older-model SLCs by Yokogawa Electric Corp. (the EBS, I, EK, and HOMAC series) allowing you to exchange instruments without modifying existing instrumentation panels. Moreover, front panel design with analog-like meters lets you update to new instruments without losing the familiarity of the old interface. line* YS* YS8* YS8* EK* I,EBS* YS compatible type internal unit Case Housing Case Housing Housing Housing *: Compatibility is established by inserting the YS s internal circuitry of the appropriate compatible type into the existing case. *: Compatibility is established by inserting the entire YS unit of the appropriate compatible type into the existing controller housing. Order the housing separately as needed. YS8 YS Self-tuning (STC) Simplifies tuning when starting up or changing the process unit under control. Setpoint filter (F) Can optimize tracking with changes in set-points. Also can maintain optimum responsiveness to disturbances. Before STC After STC Before STC P=89% P=8% P=% I =sec. I =sec. I =sec. MV 8 D= sec. SFA =. MV 8 D= sec. SFA =. P V P V P V 3 3 3 Time (min.) Time (min.) Time (min.) SFA : F Parameter MV 8 D= sec. SFA =. At disturbance optimum responsiveness to disturbances. At set-point change without F Set-point change with F optimize tracking with changes in set-points Flexible DI/DO The YS/YS s six DI/DO terminals can be used for both input and output. Programable function key With a user program, the program function key (PF key) on the instrument s front panel can be used as an ON/OFF switch for self-tuning, or as a Start button for sequence operation. Direct input function* An optional signal conversion function can be added for channel. Current, voltage pulse, thermocouples, RTDs, mv and potentiometers signals from differential pressure gauges, manometers, and flow meters can be connected directly to the controller. The direct input employs highly noise resistant, isolated inputs. TC mv RTD LOOP C 3. C.3 H.MAN C A M Pulse wire transmitter * Options available for suffix code, 3,, of Type. 8

Applications Automatic Boiler Control An appropriate distribution of control functionality enables safe and stable automatic boiler control. Chemical Injection Control -The controller can be connected with various sensors by eight analog inputs. -Feedwater flow and chemical injection volume can be controlled by the dual-loop control function. (Boiler master) Main steam pressure control FF Fx Feed water level control Cascade PRD control FF X Y X Y3 X3 X X8 X X Steam X Drum level Main steam pressure Main steam flow Feed water Air flow control Fuel flow control Exhaust gas oxygen concentration control Fx Fuel oil Fuel oil flow Air flow Oxygen Exhaust concentration gas turbidity Conductivity PH DO concentration DO saturation Dose Air -Cascade Primary Direct (PRD) control: Enables stable level control when the boiler is started. -Cross limiting control calculation: Air and fuel flow are calculated so that air flow always exceeds fuel flow to prevent incomplete combustion and explosion. -Feedforward (FF) control: The main steam pressure and feed water level are controlled quickly in response to changes in the main steam flow. Temperature Water Flow Flow Models and Suffix Codes (See General Specification Sheets for the ordereing information in the detail.) YS YS YS3 YS3 YS3 Type Model Suffix code option code Description Direct input * Certification - 3 /A /A /A3 /A /A /A /A /A8 /A3 /A3 /A3 /FM Programmable Indicating controller Indicating controller Indicator with alarm Manual setter for setting Manual setter for MV setting Always Basic type Basic type with expandable I/O type for YS (with YS case) CE marking, IP CE marking, IP CE marking type for YS8 internal unit, type for EBS, I, EK and HOMAC type for YS8 ( size for YS8 with YS terminal) type for line (with YS terminal) VAC, VDC VAC mv input Thermocouple input RTD input Potentiometer input Isolator -wire transmitter input (isolated) -wire transmitter input (non-isolated) Frequency input RS-8 communication (PC-link, Modbus, YS protocol, Peer-to-peer) * 3 * DCS-LCS communication * Ethernet communication (Modbus/TCP) * FM nonincendive approved (FM Class I, div ) * * Model Suffix code option code Description YSS - Setting software for YS series Always Always (with CD Media and proprietary cable) Option User programming Ethernet communication RS8 communication (PC-link, Modbus, YS protocol) RS8 communication (Peer-to-peer) DCS-LCS communication Direct input YS ( * ) ( * ) ( * ) YS ( * ) ( * ) * Can be added only for basic type (when selecting type or ) * Can be added only for compatible type for YS (when selecting type, and ) *3 Cannot be combined with type 3 * For basic type with expandable I/O only (when selecting type ) * /A3 and /A3 cannot be specified together. * Under development YS3 ( * ) ( * ) YS3 ( * ) ( * ) YS3 ( * ) ( * ) 9

YS Series Line-up YS Programmable Indicating Controller Incorporates A programmable controller in which control and computational functions are combined by the user with the YSS programming tool. Each YS can run two PID control calculations simultaneously and output the respective - ma output signals. The YS can also be used as a multi-function controller without programming, in the same way as the Model. Indicating Controller YS fundamental control functions required for PID control. Necessary functions can be selected in accordance with the user s purpose. The available functions include those necessary for input signal processing, such as square root extraction and linear segment conversion, and feed-forward calculation. Cascade and autoselector control is also possible. Controller mode Control type Control period Additional control function Extended control function Auxiliary control function Analog input Analog output Alarm function Degital signal Retransmission output Input computation Output computation Computation modules Program method Program capacity Security Hardmanual Programmable, Multi-function mode (single-loop, cascade and auto-selector) Basic PID control (built-in nonlinear control function),proportional control (built-in nonlinear control function), sampling PI control, (built-in sampling PI control function), and batch PID control.,. and. sec (programmable mode),. sec (multi-function mode) Adjustable setpoint filter (F), Self-tuning (STC), Non-linear PID control, PID control with reset bias function, output limiter, external cascade-control setpoint signal Input/output compensation, Variable gain, preset PID Feed-forward control, output tracking, preset MV output, / tracking, operation mode change, input filter, Square-root, -line-segment characterizer, ratio to V DC ( channels or 8 channels with with expandable I/O) to ma (or channels), to V DC ( channels or 3 channels with expandable I/O) High/low/high-high/low-low limits, deviation limit, and velocity alarm Six channels (each being common to both input and output),,,, and other analog inputs Square-root with low signal cut off, -line-segment characterizer, first-order lag calculation, scaling of external cascade-control setpoint signal, feed-forward signal calculation Output high/low limiting Four arithmetic operations, square-root, absolute, selector, limiter, ten segmen characterizer, alarm, first-order lag, differentiation, dead time, velocity computations, moving average, timer, program setting, counter, pulse output, temperature/pressure compasations, power, logarithmic, logic computations, comparison, branching, switching, sub-program and register manipulation Function block or text (use YSS configuration and programming software) modules (function block), steps (text) Protection by password Modbus/TCP, RS-8 (modbus, peer-to-peer), and DCS-LCS Yes (standard) Controller mode Control type Control period Additional control function Auxiliary control function Analog input Analog output Alarm function Degital signal Retransmission output Input computation Output computation Security Hardmanual single-loop, cascade and auto-selector Basic PID control (built-in nonlinear control function), proportional control (built-in nonlinear control function), sampling PI control, (built-in sampling PI control function). sec Adjustable setpoint filter (F), Self-tuning (STC), Nonlinear PID control, PID control with reset bias function, output limiter, external cascade-control setpoint signal Feed-forward control, output tracking, preset MV output, / tracking, operation mode change, input filter, Square-root, -line-segment characterizer, ratio to V DC ( channels) to ma ( channel) and to V DC ( channels) High/low/high-high/low-low limits, deviation limit, and velocity alarm Six channels (each being common to both input and output),,,, and other analog inputs Square-root with low signal cut off, -line-segment characterizer, first-order lag calculation, scaling of external cascade-control setpoint signal, feed-forward signal calculation Output high/low limiting Protection by password Modbus/TCP, RS-8 (modbus), and DCS-LCS Yes (standard) YS3 Indicator with Alarm YS3 Auto / Manual Station for Setting YS3 Auto / Manual Station for MV Setting YS Portable manual station Indicating alarm monitor with two inputs for simultaneous monitoring of two loops. Highhigh, high, low, and low-low alarms can be detected for each of the two inputs, and logical ANDs or ORs of arbitrary alarms can be set. From among these, a total of six alarms can be assigned to alarm output contacts. This manual loader allows an operator to send a setpoint to a remote controller. Its operation mode is switched by the mode keys (C and M) or a status input. A status identification output is provided as standard. This manual loader allows an operator to interrupt a control signal to a final control device and manually control it's operation temporally. Its operation mode is switched by the mode keys (C and M) or a status input. A status identification output is provided as standard. When a YS, YS or YS3 requires maintenance, the YS Portable Manual Station can be used to output a - ma signal to the final control element. Simply swing up the front panel of the controller, connect this unit to the controller, and replace the internal assembly while keeping the existing manipulated output active. Analog input Digital signal Alarm functions Input computation Security Trend display to V DC ( channels) Six outputs(with one for digital input as backlight off) and one FAIL contact High/low/high-high/low-low limits Square-root with low signal cut off, first-order lag calculation Protection by password Modbus/TCP, RS-8 (modbus), and DCS-LCS Analog input Analog output Digital signal Alarm functions Input computation Security Trend display to V DC ( channels) to V DC ( channel) Two input, three outputs and one FAIL contact High/low limits Square-root with low signal cut off Protection by password Modbus/TCP, RS-8 (modbus), and DCS-LCS Analog input Analog output Digital signal Alarm functions Input computation Security Trend display Hardmanual to V DC ( channels) to ma ( channel) and to V DC ( channel) Two input, three outputs and one FAIL contact High/low limits Square-root with low signal cut off Protection by password Modbus/TCP, RS-8 (modbus), and DCS-LCS Yes (standard) Input signal Manipulation signal Input/manipulation signal meters Output manipulation I/O connection Models to be backed up to V DC ( channel) to ma DC ( channel) Moving-coil method Range: to % Scaling: equal divisions Manual using the frontpanel dials I/Os are coupled with the connector on the case using a dedicated cable. YS, YS, YS3

Block YS/YS Arrangements YS YS/YS No. Programmable mode Single-loop mode Cascade mode Selector mode 3 8 9 Analog input Analog input Analog input 3 Analog input Analog input Cascade set point input Tracking input Feedforward input output (*) Cascade set point input Feedforward input output (*) Cascade set point input Cascade set point input output (*) 3 Transmitter (V DC) Transmitter (V DC) Transmitter (V DC) Transmitter (V DC) SDA () SDB () SDA () SDB () SDA () SDB () SDA () SDB () 8 RDA ()or LCS () RDA ()or LCS () RDA ()or LCS () RDA ()or LCS () RDB ()or LCS () RDB ()or LCS () RDB ()or LCS () RDB ()or LCS () 9 3 8 Direct input (*) Analog output (ma DC) Analog output Analog output 3 (ma DC/-V DC) Degital output or Direct input ( * ) MV (ma DC) MV high limit alarm Direct input ( * ) MV (ma DC) MV Direct input ( * ) MV (ma DC) MV 9 Degital input output First loop alarm output First loop alarm output 3 Degital output or low limit alarm Second loop alarm output 3 Degital input output Second loop alarm output 3 Degital output 3 or 33 Degital input Deviation alarm output O/C status output L/R status output 3 Degital output or 3 Degital input 3 C/A M status output C/A M status output C/A M status output 3 Degital output or 3 Degital input C A/M status output C A/M status output C A/M status output 38 39 L Degital output or Degital input Action mode switching input Action mode switching input Action mode switching input N G Ground (GND) Ground (GND) Ground (GND) Ground (GND) *: Only applicable for YS compatible terminal type ( ) YS Series (Basic Type) Block YS3/YS3/YS3 Arrangements No. YS3 YS3 YS3 3 8 9 output (*) Cascade set point input output (*) Cascade input output (*) 3 Transmitter (V DC) Transmitter (V DC) Transmitter (V DC) SDA () SDB () SDA () SDB () SDA () SDB () 8 RDA () RDB () RDA ()or LCS () RDA ()or LCS () RDB ()or LCS () RDB ()or LCS () 9 3 Direct input ( * ) Direct input ( * ) Direct input ( * ) MV (ma DC) MV 8 high limit alarm high limit alarm Alarm output 9 output output 3 low limit alarm low limit alarm Alarm output 3 output output 3 33 Alarm output 3 3 3 Alarm output C/M status output C/M status output 3 3 Alarm output Input for LCD backlight off Input for LCD backlight off 38 39 L Alarm output or Degital input Action mode switching input Action mode switching input N G Ground (GND) Ground (GND) Ground (GND) YS Arrangements 3 8 9 3 8 9 3 number 3 8 9 Analog input Analog input Digital input Digital input 8 Digital input 9 Digital input number 3 8 9 3 Analog input 8 Analog output ( to VDC) Digital output Digital output 8 Digital output 9 Digital output Our product names or brand names mentioned in this manual are the trademarks or registered trademarks of YOKOGAWA Electric Corporation (hereinafter referred to as YOKOGAWA). Microsoft, MS-DOS, Windows, Windows XP, and Windows NT are either registered trademarks or trademarks of Microsoft Corporation in the United States and/or other countries. Ethernet is a registered trademark of XEROX Corporation. We do not use the TM or (r) mark to indicate these trademarks or registered trademarks in this user s manual. All other product names mentioned in this user s manual are trademarks or registered trademarks of their respective companies.

Dimensions Main Unit Dimensions (YS Basic Type) When swung up Note Instrument panel thickness:.3 to mm Clamp bracket 3 3. 3.. Clamp bracket Dimensions 9 MxL8 Cable Dimensions R.- HRS -n. 9. 3. 33. (when mounted on DIN rail) lengfh:3±3cm 3 3±cm Panel Cutout Width (For single mounting) or more 8 +. 3 + Third angle projection Unit: mm or more (For side-by-side mounting) General tolerance: ±(value of tolerance class IT8 based on JIS B -998)/ Weight: Approx.. kg L + *: When attaching a nameplate or the like to the panel within mm above this instrument, ensure that its thickness is less than 3 mm. *: To ensure adequate ventilation, allow space of at least mm above and below the panel. *3: Front display of YS and YS are shown, and they are slightly different from that of YS3 (keytop and front plate and the like). 3 + Panel Cutout Width for Side-by-side Mounting Number of instruments to be mounted 3 8 9 3 L (mm) 8 3 8 88 8 93 YOKOGAWA CORPORATION OF AMERICA Dart Road, Newnan, Georgia 3, U.S.A. Phone: 8--9, Fax: ()--- YOKOGAWA EUROPE B.V. Databankweg, 38 AL Amersfoort, THE NETHERLANDS Phone: (3)-33-8, Fax: (3)-33-8 YOKOGAWA ENGINEERING ASIA PTE. LTD. Bedok South Road, Singapore 9 Phone: ()-9933, Fax: ()- Represented by : YOKOGAWA ELECTRIC CORPORATION Network Solutions Business Division -9-3 Nakacho, Musashino-shi, Tokyo, 8-8 Japan Phone: (8)---9, Fax: (8)---9 E-mail: ns@cs.jp.yokogawa.com Sign up for our free e-mail newsletter www.yokogawa.com/ns/ Vig-RM-E Printed in Japan, (KP) [Ed : /b] Subject to change without notice. All Rights Reserved, Copyright c, Yokogawa Electric Corporation.