Qualitative Comparison of Conventional and Oblique MRI for Detection of Herniated Spinal Discs

Similar documents
Lab Location: MRI, B2, Cardinal Carter Wing, St. Michael s Hospital, 30 Bond Street

New Technology Allows Multiple Image Contrasts in a Single Scan

Lucy Phantom MR Grid Evaluation

Super-resolution Reconstruction of Fetal Brain MRI

COBRE Scan Information

Optimizing MR Scan Design for Parameter Estimation (with Application to T 1, T 2 Relaxometry)

Slide 1. Technical Aspects of Quality Control in Magnetic Resonance Imaging. Slide 2. Annual Compliance Testing. of MRI Systems.

A Novel Iterative Thresholding Algorithm for Compressed Sensing Reconstruction of Quantitative MRI Parameters from Insufficient Data

Page 1 of 9. Protocol: adult_other_adni3basichumanprotocol25x_ _ _1. 3 Plane Localizer. 3 Plane Localizer PATIENT POSITION

Supplementary Information

A Virtual MR Scanner for Education

HST.583 Functional Magnetic Resonance Imaging: Data Acquisition and Analysis Fall 2008

MR Advance Techniques. Vascular Imaging. Class III

Orthopedic MRI Protocols. Philips Panorama HFO

Magnetic Resonance Elastography (MRE) of Liver Disease

Clinical Importance. Aortic Stenosis. Aortic Regurgitation. Ultrasound vs. MRI. Carotid Artery Stenosis

ANALYSIS OF PULMONARY FIBROSIS IN MRI, USING AN ELASTIC REGISTRATION TECHNIQUE IN A MODEL OF FIBROSIS: Scleroderma

Optimisation of Toshiba Aquilion ONE Volume Imaging

MITK-DI. A new Diffusion Imaging Component for MITK. Klaus Fritzsche, Hans-Peter Meinzer

ACQUIRING AND PROCESSING SUSCEPTIBILITY WEIGHTED IMAGING (SWI) DATA ON GE 3.0T

CHAPTER 9: Magnetic Susceptibility Effects in High Field MRI

MDCT and 3D Workstations

icatvision Quick Reference

Parallel Imaging. Marcin.

A Study of Medical Image Analysis System

GE Healthcare CLINICAL GALLERY. Discovery * MR750w 3.0T. This brochure is intended for European healthcare professionals.

TOF-MRA Using Multi-Oblique-Stack Acquisition (MOSA)

Following on from the two previous chapters, which considered the model of the

MRI Physics II: Gradients, Imaging

Conference Biomedical Engineering

UNIVERSITY OF SOUTHAMPTON

Role of Parallel Imaging in High Field Functional MRI

Integrating spatially resolved 3D MALDI imaging mass spectrometry with in vivo MRI

Single Breath-hold Abdominal T 1 Mapping using 3-D Cartesian Sampling and Spatiotemporally Constrained Reconstruction

Supplementary methods

DEVELOPMENT OF BIOLOGICAL VOXEL-BASED COMPUTATIONAL MODELS FROM DICOM FILES FOR 3-D ELECTROMAGNETIC SIMULATIONS

Computational Medical Imaging Analysis Chapter 4: Image Visualization

MITK-DI. A new Diffusion Imaging Component for MITK. Klaus Fritzsche, Hans-Peter Meinzer

Breast MRI Accreditation Program Clinical Image Quality Guide

HST.583 Functional Magnetic Resonance Imaging: Data Acquisition and Analysis Fall 2008

TARDIS Working Practice Document No: 035

HST.583 Functional Magnetic Resonance Imaging: Data Acquisition and Analysis Fall 2006

High dynamic range magnetic resonance flow imaging in the abdomen

Shadow casting. What is the problem? Cone Beam Computed Tomography THE OBJECTIVES OF DIAGNOSTIC IMAGING IDEAL DIAGNOSTIC IMAGING STUDY LIMITATIONS

White Pixel Artifact. Caused by a noise spike during acquisition Spike in K-space <--> sinusoid in image space

Copyright 2017 Medical IP - Tutorial Medip v /2018, Revision

MRI. When to use What sequences. Outline 2012/09/19. Sequence: Definition. Basic Principles: Step 2. Basic Principles: Step 1. Govind Chavhan, MD

ECE1778 Final Report MRI Visualizer

Functional Analysis of the Vertebral Column Based on MR and Direct Volume Rendering

SIEMENS MAGNETOM Skyra syngo MR D13

ThE ultimate, INTuITIVE Mr INTErFAcE

Joint Reconstruction of Multi-contrast MR Images for Multiple Sclerosis Lesion Segmentation

Computational Medical Imaging Analysis

Controlled Aliasing in Parallel Imaging Results in Higher Acceleration (CAIPIRINHA)

This exercise uses one anatomical data set (ANAT1) and two functional data sets (FUNC1 and FUNC2).

Multimodal Image Fusion Of The Human Brain

Process to Convert DICOM Data to 3D Printable STL Files

Quantification and Minimization of Magnetic Susceptibility Artifacts on GRE Images

M R I Physics Course

Technical Publications

Anatomic measurement accuracy: CT parameters and 3D rendering effects

Semi-Automatic Detection of Cervical Vertebrae in X-ray Images Using Generalized Hough Transform

Fiber Selection from Diffusion Tensor Data based on Boolean Operators

TUMOR DETECTION IN MRI IMAGES

3D imaging with SPACE vs 2D TSE in MR guided prostate biopsy

Optimizing Flip Angle Selection in Breast MRI for Accurate Extraction and Visualization of T1 Tissue Relaxation Time

Constrained Reconstruction of Sparse Cardiac MR DTI Data

Sparse sampling in MRI: From basic theory to clinical application. R. Marc Lebel, PhD Department of Electrical Engineering Department of Radiology

T 1 MAPPING FOR DCE-MRI

HST.583 Functional Magnetic Resonance Imaging: Data Acquisition and Analysis Fall 2008

Scan Acceleration with Rapid Gradient-Echo

Chapter 3 Set Redundancy in Magnetic Resonance Brain Images

Deep Learning for Fast and Spatially- Constrained Tissue Quantification from Highly-Undersampled Data in Magnetic Resonance Fingerprinting (MRF)

Development and anatomical details of Japanese adult male/female voxel models

Abstract. 1. Introduction

USAGE PROFILES FOR SYSTEM REQUIREMENTS

Image Acquisition Systems

SIEMENS MAGNETOM Verio syngo MR B17

Outline: Contrast-enhanced MRA

Synthetic MRI Signal Standardization: Application to Multi-atlas Analysis

Basic principles of MR image analysis. Basic principles of MR image analysis. Basic principles of MR image analysis

Technical Publications

SIEMENS MAGNETOM Verio syngo MR B15V

11/18/ CPT Preauthorization Groupings Effective January 1, Computerized Tomography (CT) Abdomen 6. CPT Description SEGR CT01

Development and Evaluation of a New Method for Measuring of Signal-to-Noise Ratio in Magnetic Resonance Images

Visualisation : Lecture 1. So what is visualisation? Visualisation

Midterm Review

Copyright 2018 Medical IP - Tutorial Medip v x 06/2018, Revision

Supplementary Figure 1

Classification of Subject Motion for Improved Reconstruction of Dynamic Magnetic Resonance Imaging

MSK EXTREME. V-SPEC Technology HIGH FIELD 1.0 TESLA TRULY OPEN, DEDICATED MRI. The Power of High Field. Rapid ROI. Optimized Performance

Machine Learning for Medical Image Analysis. A. Criminisi

The Supreme 3D/4D Ultrasound. The Supreme 3D/4D Ultrasound. CT-V20-ICM

Information about presenter

SIEMENS MAGNETOM Avanto syngo MR B15

Automatic Quantification of DTI Parameters along Fiber Bundles

Technical Publications

Semi-automated Basal Ganglia Segmentation Using Large Deformation Diffeomorphic Metric Mapping

The SIMRI project A versatile and interactive MRI simulator *

Data Loading & 3D Visualization

Transcription:

Qualitative Comparison of Conventional and Oblique MRI for Detection of Herniated Spinal Discs Doug Dean Final Project Presentation ENGN 2500: Medical Image Analysis May 16, 2011

Outline Review of the problem presented in the paper: A comparison of angled sagittal MRI and conventional MRI in the diagnosis of herniated disc and stenosis in the cervical foramen (Authors: Shim JH, Park CK, Lee JH, et. al) Approach to solve this problem Data Acquisition Analysis Methods Results Discussion/Conclusions

Review of Problem Difficult to identify herniated discs and spinal stenosis using conventional (2D) MRI techniques These conventional methods result in patients condition being misdiagnosed. Conventional MRI : Images acquired along one of three anatomical planes

Axial, T2-weighted Image: Cervical Foramen is directed at 45 degrees with respect to coronal plane. 3D reconstructive CT Image shows that the cervical foramina are directed downward around 10-15 degrees with respect to axial plane

Orientation of Images Conventional MRI: Sagittal Protocol Oblique MRI: Sagittal Protocol

Timeline Week 1 (4/11-4/16) Work on developing MR imaging protocols and sequences Recruit volunteers (~4-5 volunteers) Week 2 (4/17-4/23) Continue developing imaging sequences and begin data acquisition at the MRI facility Assisted by Dr. Deoni Week 3&4 (4/24-5/7) Continue developing and testing sequence 4/27/2011: Acquisition of first subject Mid Project Presentation: Describe the imaging protocols, present data that had been acquired from previous week, describe what still needs to be done. 5/2/2011: Finish data collection (4 other participants) Week 5&6 (5/8-5/16) 5/9/2011: Meeting with Dr. Marco Dirks (orthopedic surgeon), to analyze images and get his evaluation Continue analysis of MRI protocols. Determine which technique is best for detection of cervical foramina. Base these conclusions on the SNR and CNR measurements as well as the advice from Doctors and ROIs. 5/11/2011: Meeting with Dr. Lucy Mathews (neurologist) to analyze images and get her evaluation. 5/16/2011: Final Project Presentation

Pulse Sequences (Imaging Protocol) The following imaging sequences were developed on the MR scanner (used in Shim, Lee, Park, et al): Fast Spin Echo Sequence: Sagittal T1 weighted images: TR: 500ms TE: 10ms Matrix Size: 320x224 Echo Train Length: 3 FOV: 240mm NEX: 4 Sagittal T2 weighted images: TR: 3500ms TE: 110ms Matrix Size: 320x224 Echo Train Length: 30 FOV: 240mm NEX: 4 Axial T2 weighted images: TR: 4000ms TE: 110ms Matrix Size: 320x224 Echo Train Length: 18 FOV: 160mm NEX: 4 Slice Thickness: 3.0mm Spacing: 0.5mm

Pulse Sequence (Continued) Image Taken From: http://bitc.bme.emory.edu/seq_dia.html Spin Echo Signal Equation: TR I(x, y) =Kρ(x, y)[1 e T 1 TE ]e T 2

Pulse Sequences (Continued) In addition to the Fast Spin Echo Sequences, 3-dimensional (3D) volumetric data was also acquired However, to acquire a full volume requires a fast imaging technique such as a gradient echo sequence. To acquire the 3D volumetric data we used a spoiled gradient sequence (SPGR) as well as a Steady State Free Precession (SSFP) pulse sequence. SPGR Images This data was acquired for two purposes. First, with a 3D volume, one is able to view a slice in any particular direction, hence not limiting the researcher or clinician to one viewing direction. The second reason why this data was desired was to quantitatively fit the data to a model to determine T1 and T2 for the full volume. This step is for future work and was not the focus of this project, but will be described. SSFP Images

Pulse Sequences (Continued) In addition to the Fast Spin Echo Sequences, 3-dimensional (3D) volumetric data was also acquired However, to acquire a full volume requires a fast imaging technique such as a gradient echo sequence. To acquire the 3D volumetric data we used a spoiled gradient sequence (SPGR) as well as a Steady State Free Precession (SSFP) pulse sequence. SPGR Images This data was acquired for two purposes. First, with a 3D volume, one is able to view a slice in any particular direction, hence not limiting the researcher or clinician to one viewing direction. The second reason why this data was desired was to quantitatively fit the data to a model to determine T1 and T2 for the full volume. This step is for future work and was not the focus of this project, but will be described. SSFP Images

Pulse Sequences (Continued) SPGR Signal Equation: TR S SPGR = M 0(1 e T 1 TR 1 e T 1 )sinα cos α SSFP Signal Equation: S SSFP = M 0 (1 e TR T 1 1 e TR T 1 e TR T 2 )sinα e TR T 1 cos α General SSFP Pulse Squence Diagram Image From: http://radiology.rsna.org/content/ 241/2/338.full α represents the flip angle of the magnetization, M

Quantitative Imaging and Synthetic Imaging Quantitative imaging, in contrast to qualitative imaging, provides a way to map T1 and T2 of a volume. This mapping provides the optimal tissue contrast as well as allowing for synthetic image generation. Synthetic images are images that are artificially generated from known T1, T2 and other timing parameters generally used in MR pulse sequences (TR, TE, flip angle, etc...) Examples of T1 and T2 maps [Deoni, et al.] Thus, by knowing actual T1 and T2 values, one can generate any T1, T2 or proton density image. This is because we can model these images with their respective signal equations. To generate these T1 and T2 maps, multiple volumes are acquired and fit to a multi-variate model. These methods have been long been known to be slow. Recently, some newer methods have been developed to map T1 and T2.

Recruitment 5 adults were recruited Age range: 35-54 2-3 of them have had either back pain or other back problems in the past Scans were scheduled at Brown University s MRI Research Facility at times that were convenient for the participants (evening hours). Participants were able to comfortably relax in the scanner, either watch a movie, listen to music or sleep

Data Acquisition Data acquisition with these particular sequences take a very long time. Unable to acquire a full volume of data because of this. Instead, slices were acquired that covered the desired region of interest (cervical spine). Scanning took place in evening hours and was dependent upon schedules of participants Volumetric datasets was also collected to compare the efficiency as well as diagnostic ability. Scan Time for protocol: ~ 30 min.

Results 5 Sets of Data from 5 participants was collected T1 Weighted Sagittal T2 Weighted Axial T2 Weighted Sagittal T2 Weighted Sagittal (Oblique) Volumetric Acquisition (SPGR and SSFP acquisitions) OsiriX and FSL were used to analyze images Contours of ROIs were provided by Dr. Marco Dirks and Dr. Lucy Mathews. Further evaluations with Dr. Glenn Tung will be planned for future work on this project. Timing was an issue for not being able to schedule this. Intervertebral Foramina 2 3 4 5 6 7 T1 Weighted Sagittal T2 Weighted Axial

Image Comparisons As done in the paper, the T2 Weighted Sagittal Acquisitions were used to compare which technique (conventional or oblique) could be used to better detect the inter-vertebrae formina. Both medical professionals viewed and provided contours of the neural foramina when possible.?? Conventional T2 Weighted Sagittal Oblique T2 Weighted Sagittal

Participant 3: Side by Side Comparison #1 Oblique T2 Weighted Sagittal Conventional T2 Weighted Sagittal

Participant 3: Side by Side Comparison #2 Oblique T2 Weighted Sagittal Conventional T2 Weighted Sagittal

Participant 4: Side by Side Comparison #1 Oblique T2 Weighted Sagittal Conventional T2 Weighted Sagittal

Participant 4: Side by Side Comparison #2 Oblique T2 Weighted Sagittal Conventional T2 Weighted Sagittal

Participant 5: Side by Side Comparison #1 Oblique T2 Weighted Sagittal Conventional T2 Weighted Sagittal

Participant 5: Side by Side Comparison #2 Oblique T2 Weighted Sagittal Conventional T2 Weighted Sagittal

Comparison with Volumetric Data With a volume of data, we can slice any direction we desire Shown above are two slices acquired from the 3D SPGR sequence. The left image is an axial view of the foramen. The blue and yellow lines indicate the position of the other slices (yellow refers to a coronal view, not shown here). The blue line indicates a sagittal slice oriented perpendicular to the neural foramen and is shown in the right image. As with the Fast Spin Echo images, the neural foramen can also be seen with the 3D images. The purple axis indicates the position of the axial slice on the left. Using a DICOM viewer (OsiriX for this project) a researcher or clinician is able to slice through the 3D data at any orientation desired, unlike the 2D fast spin echo images.

Comparison with Volumetric Data Unlike the 2D fast spin echo images, one is only able to visualize either the left or the right side of the foramen, not both. Therefore, if it is necessary to view both sides, two sets of data will need to be acquired due to the slice acquisition. With a volumetric dataset, one can orient the viewing slices (indicated in blue and yellow, with the yellow slice not shown) any direction and therefore has the ability to see the opposite side of the foramen (compared with the previous slide). The purple axis on the right image indicates the position of the left axial slice.

Additional Images (Interesting Findings) During the study, disc bulging was also noticed on the conventional MRI slices. These bulges may be related to the back problems some of the participants have complained about. These bulges are indicated by the arrows in the slices

Discussion Both doctors agreed that detection of the neural foramen in the oblique sagittal T2 weighted images was much better (and possible) than in the conventional T2 weighted sagittal images. Statistically, 75% foramina was detected in the cervical spine, with the with a 98% improvement of detection when compared with the conventional techniques The acquisition of the two types of images is almost identical (only difference was the FOV and ETL parameters). However, the doctors also agreed that the oblique sagittal images took some time getting used to. This may be a reason why these types of images are not generally used in practice. Although the oblique images made it easier to detect neural foramen, one doctor thought that conventional images provided better images for looking at the vertebrae, discs and spinal cord. The doctors commented that the partial volume effects were greater in the oblique sagittal images due to the orientation of the slices (this also could be a result of the smaller FOV for the oblique sagittal images, causing the SNR to decrease) They also thought that being able to slice through a volume at any direction could be more helpful than just having a stack of 2D images. However, the quality (SNR, partial volume effects) of the images would would need to be improved for better use for diagnosis.

Conclusions Acquiring sagittal slices at an oblique angle (perpendicular to the direction of the foramen) can be used for better detection of the neural foramina This better visualization can be helpful with the diagnosis of foramina narrowing (stenosis) Although oblique images can be used for better detection of the foramina, they are more difficult to look at the entire spinal region and therefore may be a reason why they are not generally used in practice Volumetric data may provide an alternative technique for visualizing not only oblique slices, but any desired direction and therefore can provide further useful information in disease diagnosis.

Future Work Have additional doctors (Dr. Glenn Tung) evaluate the data to get more opinions, and further develop the statistics in comparing these techniques Quantitatively determine T 1 and T2 maps from the SPGR and SSFP datasets using Dr. Deoni s mapping technique. This can in turn be used to create synthetic images and may provide an alternative method to visualizing and diagnosing diseases. I plan to continue to work on this project to explore these two points in order to compare the 3D volumetric data with the 2D imaging data.

References Shim JH, Park CK, Lee JH et al (2009) A comparison of angled sagittal MRI and conventional MRI in the diagnosis of herniated disc and stenosis in the cervical foramen. Eur Spine J 18:1009 1116 Bischoff RJ, Rodriguez RP, Gupta K, Righi A, Dalton JE, Whitecloud TS (1993) A comparison of computed tomography-myelography, magnetic resonance imaging, and myelography in the diagnosis of herniated nucleus pulposus and spinal stenosis. J Spinal Disord 6:289 295. doi:10.1097/00002517-199306040- 00002 Humphreys SC, An HS, Erk JC, Coppes M, Lim TH, Estkowski L (1998) Oblique MRI as a useful adjunct in evaluation of cervical foraminal impingement. J Spinal Disord 11:295 299. doi: 10.1097/00002517-199808000-00005 Edelman RR, Stark DD, Saini S, Ferrucci JT Jr, Dinsmore RE, Ladd W et al (1986) Oblique planes of section in MR imaging. Radiology 159:807 810 Deoni SC, Peters TM, Rutt BK. High-resolution T1 and T2 mapping of the brain in a clinically acceptable time with DESPOT1 and DESPOT2. Magn Reson Med 2005; 53: 237 241. OsiriX DICOM Viewer/Imaging Software: Open Source (MAC ONLY) available at http:// www.osirix-viewer.com/index.html FMRIB Software Library (FSL): Library of tools to analyze MRI images. Available at http:// www.fmrib.ox.ac.uk/fsl/

Thank You!

Appendix of Images Participant 1: ROI of foramina from oblique sagittal image

Participant 2: Side by Side Comparison #2 Oblique T2 Weighted Sagittal Conventional T2 Weighted Sagittal

Axial Contours of Foramen

Additional Images (as video) Participant A T1 weighted Sagittal Data T2 weighted Axial Data

Additional Images (as video) Participant A T2 weighted Sagittal Data T2 weighted Sagittal Data (Oblique)

Additional Images (as video) Participant B T1 weighted Sagittal Data T2 weighted Axial Data

Additional Images (as video) Participant B T2 weighted Sagittal Data T2 weighted Sagittal Data (Oblique)

Additional Images (as video) Participant C T1 weighted Sagittal Data T2 weighted Axial Data

Additional Images (as video) Participant D T2 weighted Sagittal Data T2 weighted Sagittal Data (Oblique)

Additional Images (as video) Participant D T1 weighted Sagittal Data T2 weighted Axial Data

Additional Images (as video) Participant D T2 weighted Sagittal Data T2 weighted Sagittal Data (Oblique)