Table of Contents Table of Contents Chapter 1 Product Overview... 1-1 1.1 Preface... 1-1 1.2 System Features... 1-2 1.3 Service Features... 1-4... 2-1 2.1 S3600-28P-SI Ethernet Switch... 2-1 2.1.1 Appearance... 2-1 2.1.2 Console Port and s... 2-1 2.1.3 Attributes of the FE Ports... 2-5 2.1.4 1000 Mbps SFP Port Attributes... 2-5 2.1.5 Power Subsystem... 2-6 2.1.6 Cooling Subsystem... 2-6 2.2 S3600-28TP-SI Ethernet Switch... 2-6 2.2.1 Appearance... 2-6 2.2.2 Console Port and s... 2-7 2.2.3 Attributes of the FE Ports... 2-10 2.2.4 Attributes of 1000 Mbps SFP Ports... 2-11 2.2.5 Attributes of the GE Ports... 2-11 2.2.6 Power Subsystem... 2-12 2.2.7 Cooling Subsystem... 2-12 2.3 S3600-52P-SI Ethernet Switch... 2-12 2.3.1 Appearance... 2-12 2.3.2 Console Port and s... 2-13 2.3.3 Attributes of the FE Ports... 2-13 2.3.4 Attributes of 1000 Mbps SFP Ports... 2-13 2.3.5 Power Subsystem... 2-14 2.3.6 Cooling Subsystem... 2-14 2.4 S3600-28P-EI Ethernet Switch... 2-14 2.4.1 Appearance... 2-14 2.4.2 Console Port and s... 2-14 2.4.3 Attributes of the FE Ports... 2-18 2.4.4 Attributes of 1000 Mbps SFP Ports... 2-18 2.4.5 Power Subsystem... 2-19 2.4.6 Cooling Subsystem... 2-19 2.5 S3600-28F-EI Ethernet Switch... 2-19 2.5.1 Appearance... 2-19 2.5.2 Console port and s... 2-20 i
Table of Contents 2.5.3 Attributes of 100 Mbps SFP Ports... 2-24 2.5.4 Attributes of 1000 Mbps SFP Ports... 2-25 2.5.5 Attributes of the GE Ports... 2-25 2.5.6 Power Subsystem... 2-26 2.5.7 Cooling Subsystem... 2-26 2.6 S3600-28P-PWR-EI Ethernet Switch... 2-26 2.6.1 Appearance... 2-26 2.6.2 Console Port and s... 2-27 2.6.3 Attributes of the FE Ports... 2-31 2.6.4 Attributes of 1000 Mbps SFP Ports... 2-31 2.6.5 Power System... 2-32 2.6.6 PoE... 2-32 2.6.7 Cooling System... 2-32 2.7 S3600-28P-PWR-SI Ethernet Switch... 2-32 2.7.1 Appearance... 2-32 2.7.2 Console Port and s... 2-33 2.7.3 Attributes of the FE Ports... 2-37 2.7.4 Attributes of 1000 Mbps SFP Ports... 2-37 2.7.5 Power System... 2-38 2.7.6 PoE... 2-38 2.7.7 Cooling System... 2-38 2.8 S3600-52P-EI Ethernet Switch... 2-38 2.8.1 Appearance... 2-38 2.8.2 Console Port and s... 2-39 2.8.3 Attributes of the FE Ports... 2-39 2.8.4 Attributes of 1000 Mbps SFP Ports... 2-40 2.8.5 Power Subsystem... 2-40 2.8.6 Cooling Subsystem... 2-40 2.9 S3600-52P-PWR-EI Ethernet Switch... 2-40 2.9.1 Appearance... 2-40 2.9.2 Console Port and s... 2-41 2.9.3 Attributes of the FE Ports... 2-41 2.9.4 Attributes of 1000 Mbps SFP Ports... 2-42 2.9.5 Power Subsystem... 2-42 2.9.6 PoE... 2-42 2.9.7 Cooling Subsystem... 2-43 2.10 S3600-52P-PWR-SI Ethernet Switch... 2-43 2.10.1 Appearance... 2-43 2.10.2 Console Port and s... 2-43 2.10.3 Attributes of the FE Ports... 2-44 2.10.4 Attributes of 1000 Mbps SFP Ports... 2-44 2.10.5 Power Subsystem... 2-45 ii
Table of Contents 2.10.6 PoE... 2-45 2.10.7 Cooling Subsystem... 2-45 Chapter 3 Software Features... 3-1 3.1 Basic Features... 3-1 3.1.1 Link Aggregation... 3-1 3.1.2 Broadcast Suppression... 3-1 3.1.3 VLAN... 3-2 3.1.4 STP/RSTP/MSTP... 3-2 3.2 Network Protocol Features... 3-3 3.2.1 DHCP Client... 3-3 3.2.2 DHCP Relay... 3-4 3.2.3 UDP Helper... 3-4 3.2.4 DNS Client... 3-4 3.2.5 DHCP Server... 3-4 3.2.6 DHCP Snooping... 3-4 3.3 Routing Features... 3-5 3.3.1 Static Routing and Default Routing... 3-5 3.3.2 RIP... 3-6 3.3.3 OSPF... 3-6 3.4 Multicast Features... 3-6 3.4.1 IGMP Snooping... 3-6 3.4.2 IGMP... 3-7 3.4.3 PIM-DM... 3-7 3.4.4 PIM-SM... 3-7 3.4.5 MVR... 3-8 3.5 IRF... 3-8 3.5.1 Basic IRF... 3-8 3.5.2 Enhanced IRF... 3-8 3.6 QoS... 3-9 3.6.1 Traffic Classification... 3-9 3.6.2 Traffic Policing/Traffic Assurance... 3-9 3.6.3 Port Flow Control... 3-9 3.6.4 Port Rate-Limiting... 3-10 3.6.5 Port Mirroring... 3-10 3.6.6 Traffic Mirroring... 3-10 3.6.7 Remote Port Mirroring... 3-10 3.6.8 Queue Scheduling... 3-10 3.6.9 Traffic Shaping... 3-12 3.6.10 Priority Tag... 3-12 3.6.11 QoS Profile... 3-12 3.7 web cache redirection... 3-13 3.8 NTP... 3-13 iii
Table of Contents 3.9 Security... 3-14 3.9.1 Terminal Access User Classification... 3-14 3.9.2 SSH... 3-14 3.9.3 Port Isolation... 3-15 3.9.4 Packet Filter... 3-15 3.9.5 IEEE 802.1X Authentication... 3-15 3.9.6 Centralized MAC Address Authentication... 3-15 3.9.7 MAC Address Learning Limit... 3-16 3.9.8 MAC Address and Port Binding... 3-16 3.9.9 DUD Authentication... 3-16 3.9.10 MAC Address Black Hole... 3-16 3.9.11 AAA/RADIUS/HWTACACS... 3-16 3.9.12 MAC-IP-Port Binding... 3-17 3.10 Reliability... 3-17 3.10.1 VRRP... 3-17 3.11 Cluster Management... 3-18 3.11.1 HGMP... 3-18 3.12 QinQ... 3-18 3.12.1 QinQ... 3-18 3.12.2 QinQ BPDU Tunnel... 3-19 3.13 GARP/GVRP... 3-19 3.13.1 GARP... 3-19 3.13.2 GVRP... 3-20 Chapter 4 System Maintenance and Management... 4-1 4.1 Simple and Flexible System Maintenance... 4-1 4.1.1 System Configuration... 4-1 4.1.2 System Maintenance... 4-1 4.1.3 System Test and Diagnosis... 4-1 4.1.4 Software Upgrade... 4-1 4.2 Quidview NMS... 4-2 4.2.1 Topology Management... 4-2 4.2.2 Configuration Management... 4-2 4.2.3 Fault Management... 4-2 4.2.4 Performance Management... 4-2 4.2.5 Security Management... 4-3 4.3 Web-Based Network Management... 4-3 Chapter 5 Networking Applications... 5-1 5.1 Broadband Ethernet Access for Residential Communities... 5-1 5.2 Application in Networks of Branches or Small-to Medium-Sized Enterprises... 5-1 5.3 Application in Large Enterprise and Campus Networks... 5-3 5.4 IRF Network Diagram... 5-3 iv
Table of Contents Chapter 6 Guide to Purchase... 6-1 6.1 Purchasing the Switch... 6-1 6.2 Purchasing the SFP Interface Module... 6-2 v
Chapter 1 Product Overview Chapter 1 Product Overview 1.1 Preface are wire speed L2/L3 Ethernet switches. They are intelligent network management switches intended for the use in a network environment where high performance, dense port distribution, and ease of installation are required. Table 1-1 lists the models in the S3600 series: Table 1-1 Models in the S3600 series Model Power supply unit (PSU) Number of service ports Number of 100 Mbps ports Number of 1000 Mbps uplink ports Console port H3C S3600-28P- SI AC-input 28 24 10/100 Mbps (electrical) 4 (SFP) 1 H3C S3600-28TP -SI AC-input 28 24 10/100 Mbps (electrical) 2 (SFP) 2 10/100/1000 Mbps (electrical) 1 H3C S3600-52P- SI AC-input 52 48 10/100 Mbps (electrical) 4 (SFP) 1 H3C S3600-28P- EI AC-input, DC-input 28 24 10/100 Mbps (electrical) 4 (SFP) 1 H3C S3600-28F- EI AC-input, DC-input 28 24 100 Mbps (SFP) 2 (SFP) 2 10/100/1000 Mbps (electrical) 1 H3C S3600-28P- PWR-EI AC-input, DC-input 28 24 10/100 Mbps (electrical) 4 (SFP) 1 H3C S3600-28P- PWR-SI AC-input, DC-input 28 24 10/100 Mbps (electrical) 4 (SFP) 1 H3C S3600-52P- EI AC-input, DC-input 52 48 10/100 Mbps (electrical) 4 (SFP) 1 1-1
Chapter 1 Product Overview Model Power supply unit (PSU) Number of service ports Number of 100 Mbps ports Number of 1000 Mbps uplink ports Console port H3C S3600-52P- PWR-EI AC-input, DC-input 52 48 10/100 Mbps (electrical) 4 (SFP) 1 H3C S3600-52P- PWR-SI AC-input, DC-input 52 48 10/100 Mbps (electrical) 4 (SFP) 1 The S3600-SI series provide: Basic routing functions and service features. Basic Intelligent Resilient Framework (IRF) where devices are connected through fabric ports for centralized management. Support the feature includes DDM (Distributed Device Management). The S3600-EI series provide: Complex routing protocols and abundant service features. The Enhanced Intelligent Resilient Framework (IRF) feature, where the IRF-supported switches that are of the same type (called units) are connected to form a device union or a fabric. Trough a fabric, you can (1) manage multiple devices but with one connection and one IP address, thus decreasing the overheads; (2) expand the network by adding devices as desired, thus protecting the existing investment; and (3) have high reliability of N + 1 redundancy, thus avoiding single point failures which can result in service interruption. Support DDM (Distributed Device Management) Support DDR (Distributed Resilient Routing) Support DLA(Distributed Link Aggregation) through LACP and across devices 1.2 System Features Table 1-2 System features of the S3600 series Item Dimensions (width x height x depth) S3600 series 440 x 43.6 x 260 mm (17.32 x 1.72 x 10.24 in.) 440 x 43.6 x420 mm (17.32 x 1.72 x 16.54 in.) (S3600-28P-PWR-EI, S3600-28P-PWR-SI, S3600-52P-PWR-EI, S3600-52P-PWR-SI) 1-2
Chapter 1 Product Overview Item S3600 series S3600-28P-SI, S3600-28TP-SI, S3600-28P-EI, S3600-28F-EI: 3.5kg. Weight S3600-28P-PWR-EI, S3600-28P-PWR-SI: 5.8kg S3600-52P-SI, S3600-52P-EI: 4kg S3600-52P-PWR-EI, S3600-52P-PWR-SI: 6.2kg Management port 1 console port S3600-28P-SI: 24 x 10/100 Mbps electrical ports + 4 x 1000 Mbps SFP ports S3600-28TP-SI: 24 x 10/100 Mbps electrical ports + 2 x 1000 Mbps SFP ports + 2 x 10/100/1000 Mbps electrical ports S3600-52P-SI: 48 x 10/100 Mbps electrical ports + 4 x 1000 Mbps SFP ports Service port S3600-28P-EI: 24 x 10/100 Mbps electrical ports + 4 x 1000 Mbps SFP ports S3600-28F-EI: 24 x 100 Mbps SFP ports + 2 x 1000 Mbps ports + 2 x 10/100/1000 Mbps electrical ports S3600-28P-PWR-EI, S3600-28P-PWR-SI: 24 x 10/100 Mbps electrical ports + 4 x 1000 Mbps SFP ports S3600-52P-EI: 48 x 10/100 Mbps electrical ports + 4 x 1000 Mbps SFP ports S3600-52P-PWR-EI, S3600-52P-PWR-SI: 48 x 10/100 Mbps electrical ports + 4 x 1000 Mbps SFP ports The S3600-SI series are AC-powered and the S3600-EI series can be AC-powered or DC-powered. AC: Rated voltage: 100 to 240 VAC; 50 to 60 Hz Input voltage Max. tolerance: 90 to 264 VAC; 50 to 60 Hz DC: Rated voltage: -48 to -60 VDC. Maximum voltage: -36 to -72 VDC. S3600-28P-PWR-EI, S3600-28P-PWR-SI, S3600-52P-PWR-EI, S3600-52P-PWR-SI input voltage: -53 to -55 VDC. 1-3
Chapter 1 Product Overview Item S3600 series S3600-28P-SI, S3600-28P-EI, S3600-28TP-SI: 40W S3600-28F-EI : 65W S3600-52P-SI, S3600-52P-EI: 50W S3600-28P-PWR-EI, S3600-28P-PWR-SI: 450W (AC) Dissipated power: 150W PoE: 300W Power consumption (full load) 430W (DC) Dissipated power: 60W PoE: 370W S3600-52P-PWR-EI, S3600-52P-PWR-SI: 465W (AC) Dissipated power: 165W PoE: 300W 820W (DC) Dissipated power: 80W PoE: 740W Operating temperature Operating humidity (non-condensin g) 0 to 45 o C 10% to 90% 1.3 Service Features The software of the S3600 series is designed based on Huawei-3Com Comware. Table 1-3 summaries the available software features. Table 1-3 Software features of the S3600 series Feature S3600-SI series supports S3600-EI series supports Wire speed forwarding on all ports Wire speed L2 switching Switching mode Port capacity (24/28/52 ports): 4.8Gbps/12.8Gbps/17.6Gbps Packet forwarding speed (24/28/52 ports): 3.57Mpps/9.53Mpps/11.78Mpps Store and forward 1-4
Chapter 1 Product Overview Feature S3600-SI series supports S3600-EI series supports Virtual Local Area Network (VLAN) Voice VLAN Broadcast/multicast/ unicast suppression Loopback detection on ports 4k IEEE 802.1Q-compliant VLANs Port-based VLAN To discriminate and add IP telephony traffic to voice VLAN by MAC address Port rate ratio and PPS based suppression To detect and alarm short circuit that occurs to the data receiving and sending wires on ports The deep of IP routing table : 1k for SI series switched, 8k for EI series switches Static routing IP routing Routing Information Protocol-1/2 (RIP-1/2) Open Shortest Path First (OSPF) 3 Equal Cost Multi Paths (ECMPs) Support up to 255 multicast groups SI Series switches only support layer 2 multicast IGMP snooping Multicast Multicast VLAN registration (MVR) Internet Group Management Protocol v1/ v2 (IGMPv1/v2) PIM-SM PIM-DM spanning protocol VLAN interface UDP helper tree STP, Rapid Spanning Tree Protocol (RSTP), Multiple Spanning Tree Protocol (MSTP), MSTP supports up to 16 instances. 64 4 secondary IPs on each virtual interface, all the secondary IPs cannot exceed 64. Supported Link aggregation Dynamic link aggregation through Link Aggregation Control Protocol (LACP) Dynamic link aggregation through LACP and across devices Manual link aggregation through command lines Aggregation of FE/GE ports Up to 8 FE or 4 GE ports in each aggregation 1-5
Chapter 1 Product Overview Feature S3600-SI series supports S3600-EI series supports Up to 8 aggregation groups jumbo frame Supported Supported Mirroring Multiple-to-one port mirroring (multiple monitored ports to one monitor port) Traffic mirroring Remote port mirroring Address self-learning IEEE 802.1D standard MAC address table Up to 16K MAC addresses Up to 1k static MAC addresses Flow control IEEE 802.3x (full duplex) Back-pressure based flow control (half duplex) IRF Fabric Supported Basic IRF Fabric, up to 8 units Supported Enhanced IRF Fabric, up to 8 units PoE Supported S3600-28P-PWR-SI S3600-52P-PWR-SI, S3600-28P-PWR-EI S3600-52P-PWR-EI RPS. by and and support Loading upgrade and XModem File Transfer Protocol (FTP), Trivial File Transfer Protocol (TFTP) 1-6
Chapter 1 Product Overview Feature S3600-SI series supports S3600-EI series supports Configuration through the command line interface (CLI) Configuration through Telnet Configuration through the console port Simple Network Management Protocol (SNMP) Management Remote Monitoring ( RMON) 1/2/3/9 groups of MIBs Huawei-3Com Quidview NMS Web-based network management System log Hierarchical alarm Debug information output Maintenance Remote maintenance through Telnet Ping, traceroute Ping, traceroute, multicast traceroute Traffic rules: every 8 100M ports share 160 rules, each 1000M port supports 80 rules Limitation on packet receiving/sending rate on ports, with the granularity of 64 kbps Packet redirection Committed Access Rate (CAR), with the granularity of 64 kbps Quality of Service (QoS) Access Control List (ACL) 8 output queues on each port Five scheduling algorithms that can be set based on port and queue at the same time: Strict Priority (SP), Weighted Round Robin (WRR), Weighted Fair Queue (WFQ), SP + WFQ, SP + WRR web redirection cache Packet tagging based on 802.1p or DSCP preference Packet filter at the layers 2 through 7, providing filtering based on source/destination MAC address, source/destination IP address, port, protocol, VLAN, VLAN range, MAC address range, packet content or invalid frame Time range setting QoS profile management, allowing QoS service scheme customization Supported 1-7
Chapter 1 Product Overview Feature S3600-SI series supports S3600-EI series supports Hierarchical user management and password protection IEEE 802.1x authentication, Max on-line user connections is 1024 AAA & RADIUS & HWTACACS authentication MAC address learning limit MAC-port binding MAC-IP-port binding Disconnect Unauthorized Device (DUD) authentication, implemented through setting MAC address learning limits and binding MAC addresses with ports Security SSH Denial of Service (DoS) attack prevention Port isolation MAC address black hole Password recovery BOOTROM access control RADIUS authentication of management user IP-port binding IP-MAC binding Setting of distrusting port priority Centralized MAC address authentication WRED Dynamic Host Configuration Protocol (DHCP) Client Congestion avoidance and drop policies Supported DHCP Relay Supported Supported in addition to the DHCP security features DHCP Server Supported DHCP Snooping BOOTP NTP UDP helper Virtual router redundancy protocol (VRRP) Supported Supported Network Time Protocol (NTP) client Supported Supported 1-8
Chapter 1 Product Overview Feature S3600-SI series supports S3600-EI series supports Multicast discovery (MSDP) DNS Client source protocol Supported Supported Huawei group management protocol (HGMP) QinQ GARP VLAN registration protocol (GVRP) Fault detection and alarm Quick start Supported Supported Supported Power-on self-test (POST), and the detection and alarming of fan fault and PoE device over-temperature condition Virtual cable test (VCT) Supported 1-9
2.1 S3600-28P-SI Ethernet Switch 2.1.1 Appearance The S3600-28P-SI has 24 x 10Base-T/100Base-TX Ethernet ports, four 1000 Mbps SFP interfaces and one console port on its front panel, and on its rear panel one power input. Figure 2-2 illustrates the S3600-28P-SI: Figure 2-1 The S3600-28P-SI 2.1.2 Console Port and s I. Console port The S3600-28P-SI provides one EIA/TIA-232 compliant console port for local or remote switch configuration (see Table 2-1). II. s You can learn the operating state of the S3600-28P-SI by reading the s on its front panel (see Table 2-4). Note that at a time a port can indicate only the state of speed, duplex, or data transmission. You can toggle between them by pressing the Mode button. 2-1
Table 2-1 s on the front panel of the S3600-28P-SI Mark Color Indicates Solid green The system passes the Power-On Self-Test (POST) and is operating normally. Flashing green (1 Hz) The system POST is running. Power PWR Solid red The POST of the system fails or a serious fault is detected. Flashing yellow (1 Hz) Some ports fail to pass the POST and some functions are disabled. The power is disconnected. Speed Solid green The port s are showing the speed (for the 10/100 Mbps ports), port state (for the 1000 SFP ports or fabric ports). Mode Mode Duplex and data transmissi on Solid yellow The port s are showing the duplex mode. PoE mode 2-2
Mark Color Indicates Solid green A 100 Mbps link is present. Speed Flashing green (3 Hz) Solid yellow A 100 Mbps link is present and the port is disabled. A 10 Mbps link is present. Flashing yellow (3 Hz) A 10 Mbps link is present and the port is disabled. No link is present. 10/100B ase-tx port mode Duplex and data transmissi on Solid green Solid yellow Flashing yellow (3 Hz) The port is operating in full duplex mode, and on it data is being received/transmitted. The port is operating in half duplex mode, and on it data is being received/transmitted. No data is being received/transmitted on the port. PoE Solid green A 1000 Mbps link is present. Speed Flashing green (3 Hz) A 1000 Mbps link is present and the port is disabled. 1000Bas e SFP port mode Above the port Duplex and data transmissi on Flashing yellow (3 Hz) Solid green Solid yellow No link is present. The port is operating in full duplex mode, and on it data is being received/transmitted. The port is operating in half duplex mode, and on it data is being 2-3
Mark Color Indicates received/transmitted. Flashing yellow (3 Hz) No data is being received/transmitted on the port. PoE mode Flashing green (3 Hz) Green Solid Flashing The port is connected, and the device is in an IRF loop chain fabric. Data is being received or/and sent on the port. Speed Yellow Solid Flashing The port is connected and the device is in a non-loop chain fabric. Data is being received or/and sent on the port. 1000Bas e SFP fabric port status Flashing green (at 3Hz) Flashing yellow (at 3 Hz) Green Solid Flashing Fabricing fault occurs. The port fails to pass POST. The port is not connected. The port is in full duplex mode and is fabriced. Data is being received or/and sent on the port. Duplex Yellow Flashing yellow (at 3 Hz) The port fails to pass POST. The port is not connected. PoE mode Flashing yellow (at 3 Hz) The port fails to pass POST. 7-segme nt display Unit POST running POST failed PWR flashes green PWR flashes yellow The POST test ID (in the range 1 to 9). The POST test ID of the failed test. 2-4
Mark Color Indicates Software downloadi ng Fan failed Unit id PER flashes green PWR stays red Button released A bar rotates clockwise around the display. F, meaning the FAN fails. UNIT ID in the fabric; and for a standalone unit, 1 2.1.3 Attributes of the FE Ports Table 2-2 Attributes of the FE ports on the S3600-28P-SI Attribute Description Connector RJ-45 Number of ports 24 10 Mbps, half duplex/full duplex Rate 100 Mbps, half-duplex/full duplex MDI/MDI-X auto-sensing Standard IEEE 802.3u Transmission segment over the selected medium 100 m (328.08 ft) over the category-5 unshielded twisted pair (UTP) cable 2.1.4 1000 Mbps SFP Port Attributes Depending on your needs, the S3600-28P-SI can provide up to four 1000 Mbps SFP ports which are numbered as 25, 26, 27 and 28 (optical or electrical) on its front panel. SFP modules allow for great flexibility in networking because they are hot swappable and user configurable. Table 2-6 lists the available SFP modules: Table 2-3 1000 Mbps SFP modules and cable specifications SFP module Central wavelength Connector Fiber specifications Transmission segment 1000Base-SX-SFP 850 nm LC 50/125 µm multi-mode optical fiber 550 m (1804.46 ft.) 2-5
SFP module Central wavelength Connector Fiber specifications Transmission segment 62.5/125 µm multi-mode fiber 275 m (902.23 ft.) 1000Base-LX-SFP 1000Base-LH-SFP 1000Base-ZX-LR-S FP 1000Base-ZX-VR- SFP 1310 nm 1550 nm Single fiber mode 10 km (6.21 mi) 30 km (18.64 mi) 40 km (24.86 mi) 70 km (43.50 mi) 1000Base-TX RJ-45 100 m (328.08 ft.) Note: The available 1000 Mbps SFP modules are subject to changes. For information on the latest module options, contact your sales agent. 2.1.5 Power Subsystem Following are the input voltage specifications of the S3600-28P-SI: Rated voltage: 100 to 240 VAC; 50 to 60 Hz Max. tolerance: 90 to 264 VAC; 50 to 60 Hz 2.1.6 Cooling Subsystem The S3600-28P-SI is cooled by one fan. 2.2 S3600-28TP-SI Ethernet Switch 2.2.1 Appearance The S3600-28TP-SI has 24 x 10Base-T/100Base-TX Ethernet ports, two 1000 Mbps SFP ports, two 10/100/1000Base-T Ethernet ports, and one Console port from left to right on its front panel, and on its rear panel one AC power input. 2-6
Figure 2-2 The S3600-28TP-SI 2.2.2 Console Port and s I. Console port The S3600-28TP-SI provides one EIA/TIA-232 compliant console port for local or remote switch configuration (see Table 2-1). II. s You can learn the operating state of the S3600-28TP-SI by reading the s on its front panel, see the following table. Table 2-4 s on the front panel of S3600-28TP-SI Mark and Position Color Indicates Solid green The system passes the Power-On Self-Test (POST) and is operating normally. Power PWR Flashing green (1 Hz) Solid red The system is going through the POST or is downloading software. The POST of the system fails or a fault is detected. Flashing yellow (1 Hz) Some ports fail to pass the POST and are disabled. The power is disconnected. Mode Mode Speed Duplex Solid green Solid yellow Speed of the 10/100 Mbps ports, state of the 1000 Mbps SFP ports, or fabric state. 10/100 Mbps duplex mode, state of the 1000 Mbps SFP ports, or fabric 2-7
Mark and Position Color Indicates state. PoE POST running PWR green flashes The POST test ID (in the range 1 to 9). POST failed PWR yellow flashes POST test ID of the failed test. 7-segme nt display Unit Software loading PWR green flashes A bar rotates clockwise around the display. Fan failure Unit id PWR stays red Button released ON F, meaning the FAN fails. UNIT ID in the fabric; and for a standalone unit, 1 A 100 Mbps link is present. Green Flas h Data is being received/transmitted on the port Speed Yellow ON Flas h A 10 Mbps link is present. Data is being received/transmitted on the port Flashing yellow (3 Hz) No link is present. 10/100B ase-tx port mode Green ON Flas h The port is operating in full duplex mode Data is being received/transmitted on the port Duplex Yellow ON Flas h The port is operating in half duplex mode Data is being received/transmitted on the port Flashing yellow (3 Hz) No data is being received/transmitted on the port. PoE 1000Bas Speed Green ON A 1000 Mbps link is 2-8
Mark and Position Color Indicates e SFP port mode Flas h present. Data is being received/transmitted on the port Flashing yellow (3 Hz) No link is present. Duplex Green ON Flas h Yellow The port is operating in full duplex mode Data is being received/transmitted on the port Flashing yellow (3 Hz) No link is present. PoE Flashing green (3 Hz) 2-9
Mark and Position Color Indicates Green ON Flas h A 1000 Mbps link is present. Data is being received/transmitted on the port Speed Yellow ON Flas h A 10/100 Mbps link is present. Data is being received/transmitted on the port Flashing yellow (3 Hz) 10/100/1 000Base -T port mode Green ON Flas h No link is present. The port is operating in full duplex mode Data is being received/transmitted on the port Duplex Yellow ON Flas h The port is operating in half duplex mode Data is being received/transmitted on the port Flashing yellow (3 Hz) No data is being received/transmitted on the port. PoE 2.2.3 Attributes of the FE Ports The S3600-28TP-SI has 24 x 10Base-T/100Base-TX Ethernet ports which are numbered from 1 to 24, see the following table for port attributes. Table 2-5 Attributes of the FE ports on the S3600-28TP-SI Attribute Description Connector RJ-45 Number of ports 24 2-10
Attribute Description 10 Mbps, half duplex/full duplex Rate 100 Mbps, half-duplex/full duplex MDI/MDI-X auto-sensing Standard IEEE 802.3u Transmission segment over the selected medium 100 m (328.08 ft) over the category-5 unshielded twisted pair (UTP) cable 2.2.4 Attributes of 1000 Mbps SFP Ports The S3600-28TP-SI has two 1000 Mbps SFP ports which are numbered as 25 and 26 (optical or electrical), the number or type of ports is optional. SFP modules allow for great flexibility in networking because they are hot swappable and user configurable. Table 2-6 lists the available SFP modules. Note: The available 1000 Mbps SFP modules are subject to changes. For information on the latest module options, contact your sales agent. 2.2.5 Attributes of the GE Ports The S3600-28TP-SI has two 10/100/1000Base-T Ethernet ports which are numbered as 27 and 28. See the following table for port attributes. Table 2-6 Attributes of the GE ports on the S3600-28TP-SI Attributes Description Connector RJ-45 Number of ports 2 10/100 Mbps, half duplex/full duplex Rate 1000 Mbps, full duplex MDI/MDI-X auto-sensing Standard IEEE 802.3u 2-11
Attributes Description IEEE 802.3ab Transmission segment over the selected medium 100 m (328.08 ft) over the category-5 unshielded twisted pair (UTP) cable 2.2.6 Power Subsystem Following are the AC-input voltage specifications of the S3600-28TP-SI: Rated voltage: 100 to 240 VAC; 50 to 60 Hz Max. tolerance: 90 to 264 VAC; 50 to 60 Hz 2.2.7 Cooling Subsystem The S3600-28TP-SI is cooled by one fan. 2.3 S3600-52P-SI Ethernet Switch 2.3.1 Appearance The S3600-52P-SI has 48 x 10Base-T/100Base-TX Ethernet ports, four 1000 Mbps SFP ports and one console port on its front panel, and on its rear panel one power input. Figure 2-4 illustrates the S3600-52P-SI: Figure 2-3 The S3600-52P-SI 2-12
2.3.2 Console Port and s I. Console port The S3600-52P-SI provides one EIA/TIA-232 compliant console port for local or remote switch configuration (see Table 2-1). II. s You can learn the operating state of the S3600-52P-SI by reading the s on its front panel (see Table 2-4). 2.3.3 Attributes of the FE Ports Table 2-7 Attributes of the FE ports on the S3600-52P-SI Attribute Description Connector RJ-45 Number of ports 48 10 Mbps, half duplex/full duplex Rate 100 Mbps, half-duplex/full duplex MDI/MDI-X auto-sensing Standard IEEE 802.3u Transmission segment over the selected medium 100 m (328.08 ft) over the category-5 unshielded twisted pair (UTP) cable 2.3.4 Attributes of 1000 Mbps SFP Ports Depending on your needs, the S3600-52P-SI can provide up to four 1000 Mbps SFP ports which are numbered as 49, 50, 51 and 52 (optical or electrical) on its front panel. SFP modules allow for great flexibility in networking because they are hot swappable and user configurable. Please see to know the available SFP modules. Note: The available 1000 Mbps SFP modules are subject to changes. For information on the latest module options, contact your sales agent. 2-13
2.3.5 Power Subsystem Following are the AC-input voltage specifications of the S3600-52P-SI: Rated voltage: 100 to 240 VAC; 50 to 60 Hz Max. tolerance: 90 to 264 VAC; 50 to 60 Hz 2.3.6 Cooling Subsystem The S3600-52P-SI is cooled by one fan. 2.4 S3600-28P-EI Ethernet Switch 2.4.1 Appearance The S3600-28P-EI has 24 x 10Base-T/100Base-TX Ethernet ports, four 1000 Mbps SFP ports and one console port on its front panel, and on its rear panel one AC input and one DC input. Figure 2-5 illustrates the S3600-28P-EI: Figure 2-4 The S3600-28P-EI 2.4.2 Console Port and s I. Console port The S3600-28P-EI provides one EIA/TIA-232 compliant console port for local or remote switch configuration (see Table 2-1). II. s You can learn the operating state of the S3600-28P-EI by reading the s on its front panel (see Table 2-11). 2-14
Table 2-8 s on the front panel of the S3600-28P-EI Mark and Position Color Indicates Solid green The system passes the Power-On Self-Test (POST) and is operating normally. Power PWR Flashing green (1 Hz) Solid red The system is going through the POST. The POST of the system fails or a fault is detected. Flashing yellow (1 Hz) Some ports fail to pass the POST and are disabled. The power is disconnected. DC-input RPS Solid green Solid yellow Both the internal AC power supply and the DC input are normal. The internal AC power supply fails or is disconnected, but the DC input is normal. The DC input is not connected. Speed Solid green Speed of the 10/100 Mbps ports, state of the 1000 Mbps SFP ports, or fabric state. Mode Mode Duplex and data transmissi on Solid yellow The port s are showing the duplex mode. PoE mode Flashing green (1 Hz) 2-15
Mark and Position Color Indicates Solid green A 100 Mbps link is present. Flashing green (3 Hz) A 100 Mbps link is present and the port is disabled. Speed Solid yellow A 10 Mbps link is present. Flashing yellow (3 Hz) A 10 Mbps link is present and the port is disabled. 10/100B ase-tx port mode Above the port Duplex and data transmissi on Solid green Solid yellow Flashing yellow (3 Hz) No link is present. The port is operating in full duplex mode, and on it data is being received/transmitted. The port is operating in half duplex mode, and on it data is being received/transmitted. No data is being received/transmitted on the port. PoE mode Solid green A 1000 Mbps link is present. Speed Flashing green (3 Hz) Flashing yellow (3 Hz) A 1000 Mbps link is present and the port is disabled. No link is present. 1000Bas e SFP port mode Above the port Duplex and data transmissi on Solid green Solid yellow Flashing yellow (3 Hz) The port is operating in full duplex mode, and on it data is being received/transmitted. The port is operating in half duplex mode, and on it data is being received/transmitted. No data is being received/transmitted on the port. PoE mode Flashing green (3 Hz) 2-16
Mark and Position Color Indicates Green Solid Flashin g The port is connected, and the device is in an IRF loop chain fabric. Data is being received or/and sent on the port. Speed Yellow Solid The port is connected and the device is in a non-loop chain fabric. Flashin g Data is being received or/and sent on the port. 1000Bas e SFP fabric port status Duplex Flashing green (3Hz) Flashing yellow (3 Hz) Green Fabricing fault occurs. The port fails to pass POST. The port is not connected. Solid Yellow Flashin g The port is in full duplex mode and is fabriced. Data is being received or/and sent on the port. PoE mode Flashing yellow (at 3 Hz) Flashing yellow (at 3 Hz) The port fails to pass POST. The port is not connected. The port fails to pass POST. 2-17
Mark and Position Color Indicates POST running PWR flashes green (1 Hz) The POST test ID (in the range 1 to 9). POST failed PWR flashes yellow POST test ID of the failed test. 7-segme nt display Unit Software loading PWR flashes green A bar rotates clockwise around the display. Fan failure PWR red stays F, meaning the FAN fails. Unit id Button released UNIT ID in the fabric; and for a standalone unit, 1 2.4.3 Attributes of the FE Ports Table 2-9 Attributes of the FE ports on the S3600-28P-EI Attribute Description Connector RJ-45 Number of ports 24 10 Mbps, half duplex/full duplex Rate 100 Mbps, half-duplex/full duplex MDI/MDI-X auto-sensing Standard IEEE 802.3u Transmission segment over the selected medium 100 m (328.08 ft) over the category-5 unshielded twisted pair (UTP) cable 2.4.4 Attributes of 1000 Mbps SFP Ports Depending on your needs, the S3600-28P-EI can provide four SFP ports which are numbered as 25, 26, 27 and 28 (optical or electrical) on its front panel. SFP modules allow for great flexibility in networking because they are hot swappable and user configurable. Please see Table 2-6 to know the available SFP modules. 2-18
Note: The available 1000 Mbps SFP modules are subject to changes. For information on the latest module options, contact your sales agent. 2.4.5 Power Subsystem I. AC-input power Following are the AC-input voltage specifications of the S3600-28P-EI: Rated voltage: 100 to 240 VAC; 50 to 60 Hz Max. tolerance: 90 to 264 VAC; 50 to 60 Hz II. DC-input power DC-input voltage range: -36 VDC to -72 VDC. 2.4.6 Cooling Subsystem The S3600-28P-EI is cooled by one fan. 2.5 S3600-28F-EI Ethernet Switch 2.5.1 Appearance The S3600-28F-EI has 24 x 100 Mbps SFP ports, two 1000 Mbps SFP ports, two 10/100/1000Base-T Ethernet ports, and one Console port from left to right on its front panel, and on its rear panel both AC and DC power inputs. Figure 2-5 The S3600-28F-EI 2-19
2.5.2 Console port and s I. Console port The S3600-28F-EI provides one EIA/TIA-232 compliant console port for local or remote switch configuration (see Table 2-1). II. s You can learn the operating state of the S3600-28F-EI by reading the s on its front panel, see the following table. Table 2-10 s on the front panel of S3600-28F-EI Mark and Position Color Indicates Solid green The system passes the Power-On Self-Test (POST) and is operating normally. Power PWR Flashing green (1 Hz) Solid red The system is going through the POST or is downloading software. The POST of the system fails or a fault is detected. Flashing yellow (1 Hz) Some ports fail to pass the POST and are disabled. The power is disconnected. Speed Solid green Speed of the 10/100 Mbps ports, state of the 1000 Mbps SFP ports, or fabric state. Mode Mode Duplex Solid yellow 10/100 Mbps duplex mode, state of the 1000 Mbps SFP ports, or fabric state. PoE POST running PWR flashes green The POST test ID (in the range 1 to 9). POST failed PWR flashes yellow POST test ID of the failed test. 7-segment display Unit Software loading PWR flashes green A bar rotates clockwise around the display. Fan failure PWR stays red F, meaning the FAN fails. Unit id Button released UNIT ID in the fabric; and for a standalone unit, 1 2-20
Mark and Position Color Indicates Green ON Flash A 100 Mbps link is present. Data is being received/transmitted on the port ON A 10 Mbps link is present. Speed Yellow Flash Data is being received/transmitted on the port Flashing yellow (3 Hz) No link is present. 10/100Bas e-tx port mode Green ON Flash The port is operating in full duplex mode Data is being received/transmitted on the port Duplex Yellow ON Flash The port is operating in half duplex mode Data is being received/transmitted on the port Flashing yellow (3 Hz) No data is being received/transmitted on the port. PoE Speed Green ON Flash Flashing yellow (3 Hz) A 1000 Mbps link is present. Data is being received/transmitted on the port No link is present. 1000Base SFP port mode Duplex Green ON Flash Yellow The port is operating in full duplex mode Data is being received/transmitted on the port Flashing yellow (3 Hz) No link is present. PoE Flashing green (3 Hz) 2-21
Mark and Position Color Indicates Green ON Flash The port is connected, and the device is in an IRF loop chain fabric. Data is being received/transmitted on the port Speed Yellow ON Flash The port is connected, and the device is in an IRF loop chain fabric. Data is being received/transmitted on the port Flashing green (3 Hz) Fabricing fault occurs. 1000Base SFP fabric port status Duplex Flashing yellow (3 Hz) Green ON Flash Flashin g Yellow The port is not connected. The port is operating in full duplex mode Data is being received/transmitted on the port PoE Flashing yellow (3 Hz) Flashing yellow (3 Hz) The port is not connected. No data is being received/transmitted 2-22
Mark and Position Color Indicates Green ON Flash A 1000 Mbps link is present. Data is being received/transmitted on the port ON A 10/100 Mbps link is present. Speed Yellow Flash Data is being received/transmitted on the port Flashing yellow (3 Hz) The port is not connected. 10/100/100 0Base-T port mode Green ON Flash The port is operating in full duplex mode Data is being received/transmitted on the port Duplex Yellow ON Flash The port is operating in half duplex mode Data is being received/transmitted on the port Flashing yellow (3 Hz) No data is being received/transmitted on the port. PoE 2-23
Mark and Position Color Indicates Green ON Flash The port is connected, and the device is in an IRF loop chain fabric. Data is being received/transmitted on the port Speed Yellow ON Flash The port is connected, and the device is in an IRF loop chain fabric. Data is being received/transmitted on the port Flashing green (3 Hz) Fabricing fault occurs. 10/100/100 0Base-T fabric port status Duplex Flashing yellow (3 Hz) Green ON Flash Yellow The port is not connected. The port is operating in full duplex mode Data is being received/transmitted on the port PoE Flashing yellow (3 Hz) Flashing yellow (3 Hz) The port is not connected. No data is being received/transmitted 2.5.3 Attributes of 100 Mbps SFP Ports The S3600-28F-EI has 24 x 100 Mbps SFP optical ports which are numbered from 1 to 24. SFP modules allow for great flexibility in networking because they are hot swappable and user configurable. The following table lists the available SFP modules. 2-24
Table 2-11 100 Mbps SFP modules and cable specifications SFP module Central wavelength Connector Fiber specifications Transmission segment 100Base-FX-MM-SFP 62.5/125 µm multi-mode fiber 2 km (1.24 mi) 100Base-FX-SM-SFP 100Base-FX-SM-LR-SF P 1310 nm LC 9/125µm single mode fiber 9/125µm single mode fiber 15 km (9.32 mi) 40 km (24.86 mi) 100Base-FX-SM-VR-SF P 1550 nm 9/125µm single mode fiber 80 km (49.71 mi) 2.5.4 Attributes of 1000 Mbps SFP Ports The S3600-28F-EI has two 1000 Mbps SFP ports which are numbered as 25 and 26 (optical or electrical), the number or type of ports is optional. SFP modules allow for great flexibility in networking because they are hot swappable and user configurable. Table 2-6 lists the available SFP modules. Note: The available 1000 Mbps SFP modules are subject to changes. For information on the latest module options, contact your sales agent. 2.5.5 Attributes of the GE Ports The S3600-28F-EI has two 10/100/1000Base-T Ethernet ports which are numbered as 27 and 28, see the following table for port attributes. Table 2-12 Attributes of the FE ports on the S3600-28F-EI Attribute Description Connector RJ-45 2-25
Attribute Description Number of ports 2 10/100 Mbps, half duplex/full duplex Rate 1000 Mbps full duplex MDI/MDI-X auto-sensing Standard Transmission segment over the selected medium IEEE 802.3u IEEE 802.3ab 100 m (328.08 ft) over the category-5 unshielded twisted pair (UTP) cable 2.5.6 Power Subsystem I. AC-input power Rated voltage: 100 to 240 VAC; 50 to 60 Hz Max. tolerance: 90 to 264 VAC; 50 to 60 Hz II. DC-input power Rated voltage: -48 to -60 VDC. Max. tolerance: -36 to -72 VDC. 2.5.7 Cooling Subsystem The S3600-28F-EI is cooled by two fans. 2.6 S3600-28P-PWR-EI Ethernet Switch 2.6.1 Appearance The S3600-28P-PWR-EI has 24 x 10Base-T/100Base-TX Ethernet ports, four 1000 Mbps SFP ports, and one Console port on its front panel, and on its rear panel both AC and DC power inputs. 2-26
Figure 2-6 The S3600-28P-PWR-EI 2.6.2 Console Port and s I. Console port The S3600-28P-PWR-EI provides one EIA/TIA-232 compliant console port for local or remote switch configuration (see Table 2-1). II. s You can learn the operating state of the S3600-28P-PWR-EI by reading the s on its front panel, see the following table. Table 2-13 s on the front panel of S3600-28P-PWR-EI Mark and Position Color Indicates Solid green The system passes the Power-On Self-Test (POST) and is operating normally. Power PWR Flashing green (1 Hz) Solid red The system is going through the POST or is downloading software. The POST of the system fails or a fault is detected. Flashing yellow (1 Hz) Some ports fail to pass the POST and are disabled. The power is disconnected. DC-input RPS Solid green Solid yellow Both the internal AC power supply and the DC input are normal. The internal AC power supply fails or is disconnected, but the DC input is normal. The DC input is not connected. 2-27
Mark and Position Color Indicates Speed Solid green 10/100 Mbps duplex mode, state of the 1000 Mbps SFP ports, or fabric state. Mode Mode Duplex Solid yellow 10/100 Mbps duplex mode, state of the 1000 Mbps SFP ports, or fabric state. PoE Flashing green (1 Hz) PoE information on 10/100M port. POST running PWR green flashes The POST test ID (in the range 1 to 9). POST failed PWR yellow flashes POST test ID of the failed test. Software loading PWR green flashes A bar rotates clockwise around the display. 7-segment display Unit Fan failure PWR stays red F, meaning the FAN fails. Unit id Button released UNIT ID in the fabric; and for a standalone unit, 1 Temperat ure alarm PWR stays red t PoE utilization Button pressed The ratio of the power used by PoE to the total power 2-28
Mark and Position Color Indicates Green ON Flash A 100 Mbps link is present. Data is being received/transmitted on the port ON A 10 Mbps link is present. Speed Yellow Flash Data is being received/transmitted on the port Flashing yellow (3 Hz) No link is present. Green ON Flash The port is operating in full duplex mode Data is being received/transmitted on the port 10/100Bas e-tx port mode Duplex Yellow ON Flash The port is operating in half duplex mode Data is being received/transmitted on the port PoE Flashing yellow (3 Hz) Solid green Flashing green (3 Hz) Solid yellow Flashing yellow (3 Hz) No data is being received/transmitted on the port The port is providing power Exceeds the upper limit of power consumption on the port or the left power is not enough. PoE fault occurs, the port cannot provide power normally. The port does not provide power. 2-29
Mark and Position Color Indicates Speed Green ON Flash Flashing yellow (3 Hz) A 1000 Mbps link is present. Data is being received/transmitted on the port No link is present. 1000Base SFP port mode Duplex Green ON Flash The port is operating in full duplex mode Data is being received/transmitted on the port Flashing yellow (3 Hz) No link is present. PoE Flashing green (3 Hz) Green ON Flash The device is in IRF mode Data is being received/transmitted on the port Speed Yellow ON Flash The device is in a non-loop chain fabric. Data is being received/transmitted on the port Flashing green (3 Hz) Fabricing fault occurs. 1000Base SFP fabric port status Duplex Flashing yellow (3 Hz) Green ON Flash Yellow The device is not in fabric mode. The port is in full duplex mode and is fabriced. Data is being received or/and sent on the port. PoE Flashing yellow (3 Hz) Flashing yellow (3 Hz) The device is not in fabric mode. No data is being received/transmitted 2-30
2.6.3 Attributes of the FE Ports Table 2-14 Attributes of the FE ports on the S3600-28P-PWR-EI Attribute Description Connector RJ-45 Number of ports 24 10 Mbps, half duplex/full duplex Rate 100 Mbps, half-duplex/full duplex MDI/MDI-X auto-sensing Supporting PoE Standard Transmission segment over the selected medium IEEE 802.3u IEEE 802.3af 100 m (328.08 ft) over the category-5 unshielded twisted pair (UTP) cable 2.6.4 Attributes of 1000 Mbps SFP Ports The S3600-28P-PWR-EI has four 1000 Mbps SFP ports which are numbered as 25, 26, 27, and 28 (optical or electrical), the number or type of ports is optional. Note: SFP module does not support PoE. SFP modules allow for great flexibility in networking because they are hot swappable and user configurable. Table 2-6 lists the available SFP modules. Note: The available 1000 Mbps SFP modules are subject to changes. For information on the latest module options, contact your sales agent. 2-31
2.6.5 Power System I. AC-input power Rated voltage: 100 to 240 VAC; 50 to 60 Hz Max. tolerance: 90 to 264 VAC; 50 to 60 Hz II. DC-input power Voltage: -53 to -55 VDC. 2.6.6 PoE The S3600-28P-PWR-EI switch provides PoE (Power over Ethernet), that is, to supply -48V DC power to the remote powered device (PD), such as IP phone, WLAN wireless access points (AP), Security, Bluetooth AP, through the twisted pair cable. As the power sourcing equipment (PSE), S3600-28P-PWR-EI supports IEEE802.3af standard, and is also compatible with PDs that is not conformed to this standard. The S3600-28P-PWR-EI provides power through 24 fixed Ethernet electrical ports, and thus is able to support up to 24 remote Ethernet switches with a maximum transmission distance of 100 m (328 ft). The maximum power of each Ethernet port for the remote PD is 15.4 W. PoE input voltage ranges from -53 VDC to -55 VDC. 2.6.7 Cooling System The S3600-28P-PWR-EI is cooled by five fans. 2.7 S3600-28P-PWR-SI Ethernet Switch 2.7.1 Appearance The S3600-28P-PWR-SI has 24 x 10Base-T/100Base-TX Ethernet ports, four 1000 Mbps SFP ports, and one Console port on its front panel, and on its rear panel both AC and DC power inputs. 2-32
Figure 2-7 The S3600-28P-PWR-SI 2.7.2 Console Port and s I. Console port The S3600-28P-PWR-SI provides one EIA/TIA-232 compliant console port for local or remote switch configuration (see Table 2-1). II. s You can learn the operating state of the S3600-28P-PWR-SI by reading the s on its front panel, see the following table. Table 2-15 s on the front panel of S3600-28P-PWR-SI Mark and Position Color Indicates Solid green The system passes the Power-On Self-Test (POST) and is operating normally. Power PWR Flashing green (1 Hz) Solid red The system is going through the POST or is downloading software. The POST of the system fails or a fault is detected. Flashing yellow (1 Hz) Some ports fail to pass the POST and are disabled. The power is disconnected. DC-input RPS Solid green Solid yellow Both the internal AC power supply and the DC input are normal. The internal AC power supply fails or is disconnected, but the DC input is normal. The DC input is not connected. 2-33
Mark and Position Color Indicates Speed Solid green 10/100 Mbps duplex mode, state of the 1000 Mbps SFP ports, or fabric state. Mode Mode Duplex Solid yellow 10/100 Mbps duplex mode, state of the 1000 Mbps SFP ports, or fabric state. PoE Flashing green (1 Hz) PoE information on 10/100M port. POST running PWR green flashes The POST test ID (in the range 1 to 9). POST failed PWR yellow flashes POST test ID of the failed test. Software loading PWR green flashes A bar rotates clockwise around the display. 7-segment display Unit Fan failure PWR stays red F, meaning the FAN fails. Unit id Button released UNIT ID in the fabric; and for a standalone unit, 1 Temperat ure alarm PWR stays red t PoE utilization Button pressed The ratio of the power used by PoE to the total power 2-34
Mark and Position Color Indicates Green ON Flash A 100 Mbps link is present. Data is being received/transmitted on the port ON A 10 Mbps link is present. Speed Yellow Flash Data is being received/transmitted on the port Flashing yellow (3 Hz) No link is present. Green ON Flash The port is operating in full duplex mode Data is being received/transmitted on the port 10/100Bas e-tx port mode Duplex Yellow ON Flash The port is operating in half duplex mode Data is being received/transmitted on the port PoE Flashing yellow (3 Hz) Solid green Flashing green (3 Hz) Solid yellow Flashing yellow (3 Hz) No data is being received/transmitted on the port The port is providing power Exceeds the upper limit of power consumption on the port or the left power is not enough. PoE fault occurs, the port cannot provide power normally. The port does not provide power. 2-35
Mark and Position Color Indicates Speed Green ON Flash Flashing yellow (3 Hz) A 1000 Mbps link is present. Data is being received/transmitted on the port No link is present. 1000Base SFP port mode Duplex Green ON Flash The port is operating in full duplex mode Data is being received/transmitted on the port Flashing yellow (3 Hz) No link is present. PoE Flashing green (3 Hz) Green ON Flash The device is in IRF mode Data is being received/transmitted on the port Speed Yellow ON Flash The device is in a non-loop chain fabric. Data is being received/transmitted on the port Flashing green (3 Hz) Fabricing fault occurs. 1000Base SFP fabric port status Duplex Flashing yellow (3 Hz) Green ON Flash Yellow The device is not in fabric mode. The port is in full duplex mode and is fabriced. Data is being received or/and sent on the port. PoE Flashing yellow (3 Hz) Flashing yellow (3 Hz) The device is not in fabric mode. No data is being received/transmitted 2-36
2.7.3 Attributes of the FE Ports Table 2-16 Attributes of the FE ports on the S3600-28P-PWR-SI Attribute Description Connector RJ-45 Number of ports 24 10 Mbps, half duplex/full duplex Rate 100 Mbps, half-duplex/full duplex MDI/MDI-X auto-sensing Supporting PoE Standard Transmission segment over the selected medium IEEE 802.3u IEEE 802.3af 100 m (328.08 ft) over the category-5 unshielded twisted pair (UTP) cable 2.7.4 Attributes of 1000 Mbps SFP Ports The S3600-28P-PWR-SI has four 1000 Mbps SFP ports which are numbered as 25, 26, 27, and 28 (optical or electrical), the number or type of ports is optional. Note: SFP module does not support PoE. SFP modules allow for great flexibility in networking because they are hot swappable and user configurable. Table 2-6 lists the available SFP modules. Note: The available 1000 Mbps SFP modules are subject to changes. For information on the latest module options, contact your sales agent. 2-37
2.7.5 Power System I. AC-input power Rated voltage: 100 to 240 VAC; 50 to 60 Hz Max. tolerance: 90 to 264 VAC; 50 to 60 Hz II. DC-input power Voltage: -53 to -55 VDC. 2.7.6 PoE The S3600-28P-PWR-SI switch provides PoE (Power over Ethernet), that is, to supply -48V DC power to the remote powered device (PD), such as IP phone, WLAN wireless access points (AP), Security, Bluetooth AP, through the twisted pair cable. As the power sourcing equipment (PSE), S3600-28P-PWR-SI supports IEEE802.3af standard, and is also compatible with PDs that is not conformed to this standard. The S3600-28P-PWR-SI provides power through 24 fixed Ethernet electrical ports, and thus is able to support up to 24 remote Ethernet switches with a maximum transmission distance of 100 m (328 ft). The maximum power of each Ethernet port for the remote PD is 15.4 W. PoE input voltage ranges from -53 VDC to -55 VDC. 2.7.7 Cooling System The S3600-28P-PWR-SI is cooled by five fans. 2.8 S3600-52P-EI Ethernet Switch 2.8.1 Appearance The S3600-52P-EI has 48 x 10Base-T/100Base-TX Ethernet ports, four 1000 Mbps SFP ports and one console port on its front panel, and on its rear panel one AC-input and one DC-input. 2-38