RGBW PAR CANS. Item ref: SL-FC3, SL-36, SL-64, SL-SW, SL-Q8, SL-Q12 User Manual. Errors and omissions excepted. Copyright AVSL Group Ltd.

Similar documents
Spectrum Laser. User manual UK. Version 1.0

3D OBJECTS RGB LASER. Order ref: UK User Manual

Blue Weapon Laser. User manual UK. Version 1.0

Item ref: UK User Manual. MW-7 4-in-1 LED Mini Moving Head

FUSION SPOT MKII EQUINOX. Contents. User Manual. Order codes: Black housing - EQLED Safety Instructions. 2. Features & Specifications

LED PANEL. User Manual Please read the instructions carefully before use LED-7TC. Innovation, Quality, Performance 15-

LED MOVING HEAD FLEX BEAM K8 RGBW. User Manual. Please read the instruction carefully before use

VBAR 270. User Manual. Version 1.2

LED PANEL. User Manual Please read the instructions carefully before use LED-212RGB TABLE OF CONTENTS. 1. Safety Instructions

LIGHT BRICK - 12 X 3W TRI-COLOUR

Order code: EQLED53 User manual

ZEPHYR Compact Haze Machine

36LEDs Par Light. User Manual

i.shine 1136 RGBW Color Stainer CN USER MANUAL

User Manual for: Professional DJ Multi Beam LED Seashell Stage Effect Light with DMX. MODEL: LG8xSEA

LED W RGBA User Manual

STAGE TRI-PAR 18TC CP-18TC. User Manual. Please read the instructions carefully before use

PROFESSIONAL SHOW LIGHT

i.shine 3148 RGBW Color Stainer XP USER MANUAL

TourPro RGBAW Stagebar USER MANUAL

FLEX BEAM V8. User Manual Please read the instruction carefully before use

ALO Duo Roll DMX LED barrel scanner with dual light source

SAMURAI SCAN 50 LED-SC50D. User Guide. Innovation, Quality, Performance. Professional Entertainment Technology 19-

LED SPIDER MOVING HEAD LIGHT

GLX LED STAGE 4 MANUAL GLS-4 LED STAGE 4. owners manual

User Instructions. American DJ

Professional Entertainment Technology. imove 50SR. Innovation, Quality, Performance 21-

Snapshot. Data Stream 4 USER MANUAL

10W LED PIN SPOT. User Manual LED-PS10D W. Innovation, Quality, Performance. Professional Entertainment Technology 11-

N-E Color Par 64 USER MANUAL

4. How to Connect the Fixture 3-Pin and 5-Pin XLR DMX Connectors:

Please read the instructions carefully before use LED PYRAMID LED-904D. Innovation, Quality, Performance 15-

Snapshot. User Manual. Use on Dimmer Outdoor Use Sound-Activated DMX Master/Slave 120/230 V switch Replaceable Fuse User-Serviceable

TECHNICAL DATA. V-PIX Quad Bar. Product code CL-VPIX-4-40 Light colour Full spectrum 8 / 480 (see above)

Robot Light V2. User Manual

CP 64 BD15 CP 64 PD15

Springtree Spatial Wash COB RGBW

BW-108. Building Wash BW-108. User Guide. Advanced LED Technology

RGB Power Batten. User Manual. Order code: EQLED032

Slimline CW & WW Series

DarkFX Spot 670 User Manual English

COLOR PAR 56 COLOR PAR 64. User Manual Please read the instructions carefully before use. Широкий ассортимент оборудования ACME на

User Manual for: Professional DJ Multicolor LED Pin Spotlight With DMX. MODEL: LGSPOT1x

LED DANCING FLOOR User Manual

SP-1500 DMX MK II Strobe

MICRON DJ Booth Tri-colour Starcloth

LED BEAM 300 LED-MB50. User. Guide. Professional Entertainment Technology

Professional Entertainment Technology LED BEAM 300 LED-MB50. Innovation, Quality, Performance 23-

1 Channel Strobe Controller ORDERCODE 40226

Professional Entertainment Technology LED BEAM 300 LED-MB50. User. Guide

LED Par 64 Short DMX ORDERCODE 42431

Vortex. User Manual. Order code: EQLED073

User Manual Please read the instructions carefully before use

MATRIX LED LED User Manual Please read the instructions carefully before use

User Manual. Snapshot. Use on Dimmer. Outdoor Use. Sound Activated DMX 512. Master/Slave Autoswitching Power Supply Replaceable Fuse.

Check that the unit has not been damaged during transport

Fusion Razor Beam. 3 x 12W Moving Head User Manual. Order code: EQLED006

7x15W 4IN1 Infinity Rotation LED Pixel Bar. This product manual contains important information about the safe

w w w. p r o l i g h t. c o. u k STAGE PAR 64

TDC Power Derby DMX LED light effect

Cluster FX-Bar. Portable performance lighting and laser rig

Spider Light. User Manual. Model: LM80. Big Dipper Laser Science And Technology Co., Ltd REV;1.01. Please read this manual carefully before operating

UV Spectra Batten 12 x 5W UV LEDs

Fusion Saber. User Manual. Order code: EQLED070

Snapshot. LED-PALET COLORpalette USER MANUAL

xbrick Full-Colour 16 3W LED floodlight user manual

Performer 18 HEX. 18 x 12W 6-in-1 colour LEDs (RGBWAUV) User Manual. Order code: LEDJ252B

Ostar Eye K18. Beam and Kaleido Effects. User manual. 6. Fixture Cleaning. Please read the instructions carefully before use

Performer 18 RGBWA MKII

Hypnos. User Manual. Order code: EQLED372

FT-20 Fire Training Fog Machine User Manual English

X-3 LED. Owner s Manual ROBOHEAD

User Manual 4BAR. Snapshot. (Included) Use on Dimmer Outdoor Use. Sound Activated DMX. Master/Slave Autoswitching Power Supply Replaceable Fuse

Blitzer RGB Strobe. User Manual. Order code: EQLED365

w w w. p r o l i g h t. c o. u k Quad Par 64 (Order code: LEDJ46 - Black) (Order code: LEDJ47 - Polished) USER MANUAL

LED Dancefloor ORDERCODE 42300

Z-350 FAZER USER MANUAL

Snapshot. LED Mushroom USER MANUAL

CM/CS SERIES. Compact 100V amplifiers. Item ref: UK, UK, UK User Manual. CM/CS Series User Manual

Octostrip ORDERCODE 42220

Ostar Eye K6. Beam and Kaleido Effects. User manual. Please read the instructions carefully before use

TABLE OF CONTENTS. Returns Contact Us... 17

Snapshot. Double Derby X. User Manual

CUBE3 RGB TRI LED User Manual (Battery Powered DMX LED Fixture)

User Manual. Snapshot. Use on Dimmer. Outdoor Use. Sound Activated DMX. Master/Slave. Auto-ranging Power Supply. Replaceable Fuse.

TABLE OF CONTENTS 1. Before You Begin Introduction Setup Operation Technical Information...14

Beam Stage Light (RGBW)

1. BEFORE YOU BEGIN INTRODUCTION SETUP... 7

COB100/200W 2in1/3in1 led Par Light

Warning... Safety-instructions Operating Determinations Rigging... Description... Features and Overview...

1. BEFORE YOU BEGIN INTRODUCTION SETUP... 6

Microbar COB System. User Manual. Order code: EQLED137

1. BEFORE YOU BEGIN INTRODUCTION SETUP... 7

Blitzer Strobe. User Manual. Order code: EQLED366

1. BEFORE YOU BEGIN INTRODUCTION SETUP AC POWER... 6 Power Linking... 6 MOUNTING... 7 Orientation... 7 Rigging...

Alu HEX Par 64. (12 x 12W six-colour LEDs RGBWAUV) User Manual. Order code: ELUM114

LED Blinder 2 COB 2 65 W blinder. user manual

FT-20 Fire Training Fog Machine User Manual English

LED Slimline PAR RGBW 7x8W

Snapshot. LED-PALET COLORpalette USER MANUAL

Transcription:

RGBW PAR CANS Item ref: SL-FC3, SL-36, SL-64, SL-SW, SL-Q8, SL-Q12 User Manual Errors and omissions excepted. Copyright 2012. AVSL Group Ltd. VERSION 1.0 SmartLIGHT User Manual Page 20

INTRODUCTION: LED SMARTLIGHT RGBW PAR CANS The QTX SmartLIGHT family of LED Par cans have been designed for a variety of applications, whether you re a mobile DJ, a band/singer, a bar/nightclub, theater company or production company then this range of PAR cans will cover most requirements. Please read this manual carefully to ensure you get the best out of these products. This manual covers the following models: SL-36, SL-64, SL-SW, SL-Q8 and SL-FC3 Contents: Page 3 6 Page 7 9 Product Safety and Installation instructions SmartLIGHT Product layout Page 10 11 SmartLIGHT Operation and functions Page 12 13 SmartLIGHT DMX Operation Page 14 16 SL-FC3 Controller Operations Page 17 Product Specifications SmartLIGHT User Manual Page 2 SmartLIGHT User Manual Page 19

PACKAGE CONTENTS: Please check the contents to ensure that the product has been received in good condition. SmartLIGHT Box: SmartLIGHT Unit x 1pcs User s Guide x 1pcs Power Cord x 2pcs (EU and UK) Mounting brackets x 2pcs Controller Box: SL-FC3 Controller x 1pcs 5m cable x 1pcs User s Guide x 1pcs If you find any accessory is missing or the product has arrived with any problems, please contact your local dealer at once. Do not try to fix this item yourself or you will lose the warranty. Please keep the original package and invoice for any possible replacement or returned demand. INSTALLATION: Every person involved with the installation, operation and maintenance of this device should be qualified and follow the instructions in this User Guide. We recommend that this product should be used within the guidelines of HSG95. When you connect to the main power supply the device will take a few seconds before ready for use. MOUNTING INSTRUCTIONS: The mounting brackets are already attached to the product when you open the box but you can adjust them giving more clearance. You can use them as floor standing or you can fix a G-Clamp to the bracket securely ready for mounting. After finding the desired position tighten the G-Clamp and use a safety wire the security loop for extra security. When selecting an installation location, take into consideration routine maintenance. Safety cables must always be used. Never mount in places where the fixture will be exposed to rain, high humidity, extreme temperatures changes or restricted ventilation. SmartLIGHT User Manual Page 18 SmartLIGHT User Manual Page 3

CAUTION! TO PREVENT MORTAL ELECTRICAL RISK AND LONG LIFE OPERATION: TECHNICAL SPECIFICATION: For your safety, please kindly pay attention to all of the warnings listed below: Always plug in the power plug last and disconnect from the mains, when the device is not in use or before cleaning. Do not install and operate the device in rain or extreme heat, moisture or dusty environments. This device is for indoor use only and in a dry environment. Do not switch on immediately but wait until it reaches to room temperature, if the device has been exposed to drastic temperature fluctuations. Do not shake the device and avoid brute force when installing or operating. Do not spread a fog or bubble effect machine directly at the device. Do not use the device during thunderstorms. Disconnect the power. Do not use solvents or aggressive detergent to clean the device. Use a soft and clean cloth. Do not modify the device or the power cord in anyway. Use appropriate safety-rope for added safety. For more information visit www.avsl-qtx.com Do not stare to the light. The symbol determines the minimum distance from lighted objects. The minimum distance between light-output and the illuminated surface must be more than 0.5m. DISPOSAL: Please disposal of an unserviceable device according to the current statutory requirement SmartLIGHT User Manual Page 4 SmartLIGHT User Manual Page 17

LED FOOT CONTROLLER OPERATION: CONNECT WITH POWER SUPPLY THE GROUND WIRE MUST BE CONNECTED: Use the IEC plug to connect to the main power supply as follows: Wire Connection International signal Brown Live L Blue Neutral N Yellow /Cyan Earth QUICK TROUBLE SHOOTING If the unit is not functioning properly follow the below guidelines Check the IEC cable is fitted correctly. Check the fuse hasn t blown in both the IEC cable and unit (see below) Check any DMX cables are connected correctly Check the DMX address has been set correctly Check the operating mode of the device (see later on in this manual) If the unit still fails to respond then contact your retailer. DO NOT ATTEMPT TO REPAIR YOURSELF. REPLACING FUSE First disconnect from the main power supply then remove the fuse holder above the IEC Socket to reveal the fuse. Replace with the correct fuse rating as stated on the product safety label. Then lock the fuse holder cover back into place. SmartLIGHT User Manual Page 16 SmartLIGHT User Manual Page 5

GENERAL MAINTENANCE To maintain optimum performance and minimise wear, fixtures should be cleaned frequently. Usage and environment are contributing factors in determining frequency. As a general rule, fixtures should be cleaned at least twice a month. Dust build-up reduces light output performance and can cause overheating. This can lead to reduced life and increased mechanical wear. Be sure to power off the fixture before conducting maintenance. Unplug fixture from the mains and use a vacuum or air compressor and a soft brush to remove dust collected on external vents and internal components. Clean all glass and Perspex when fixture is cold with a mild cleaning solution to the cloth or tissue, and drag dirt and grime to the outside of the lens. Gently polish optical surface until they free of haze and lint. The cleaning of external optical lenses must be carried out periodically to optimise light output. Cleaning frequently depends on the environment in which the fixture operates: damp, smoky or particularly dirty surroundings can require cleaning fluid. Always dry the parts carefully. Clean the external optics at least every 20 days. Once all the fixtures are setup turn the power on and set the DMX address on each model to A001. For users who wish to use the sound to light 4 light chase sequences set the DMX to each of the following: Connecting in 4 s 1 st PAR can = A001 2 nd PAR can = A007 3 rd PAR can = A013 4 th PAR can = A019 If you are connecting more than four in a chain either start again or work backwards. Maybe try your own combination but note you may only connect up to a maximum of 32 PAR cans in any one sequence. SmartLIGHT User Manual Page 6 SmartLIGHT User Manual Page 15

SL-FC3 FOOT CONTROLLER: FRONT LAYOUT GENERAL: A combination of up to 32 SmartLIGHT fixtures can be operated by one SL-FC3 controller. SETUP: First connect the foot controller to the first fixture using the supplied cable as shown below. Connecting more than one fixture to the chain requires 3 pin DMX XLR Leads (available at most retailers). 1. LED Output 2. Secondary bracket 3. Mounting point for G-Clamp 4. Secondary mounting points for more clearance 5. Thumb screw to hold brackets in place 6. Primary bracket SmartLIGHT User Manual Page 14 SmartLIGHT User Manual Page 7

REAR LAYOUT SL-36: DMX OPERATIONS: DMX DMX Channel Value Function 1 000-255 Red Colour 0-100% Dimming 2 000-255 Green Colour 0-100% Dimming 3 000-255 Blue Colour 0-100% Dimming 4 000-255 White Colour 0-100% Dimming 5 000-255 Master Dimming 0-100% 6 000-250 Strobe Slow to Fast 251-255 Sound Activated 1. LED Display 2. Sound sensitivity 3. IEC Power IN (Fuse F1A) 4. Microphone 5. DMX IN 6. DMX OUT 7. Connection to SL-FC3 Foot controller (sold separately) SmartLIGHT User Manual Page 8 SmartLIGHT User Manual Page 13

DMX REAR LAYOUT SL-64, SL-SW, SL-Q8 and SL-Q12: The fixture is equipped with 3-pin XLR connectors for DMX input and output. The SE connectors are wired in parallel. Only use a shielded twisted-pair cable designed for 3-pin XLRplugs and connectors in order to connect the controller with the fixture or one fixture with another. Building a serial DMX-chain: 1. DMX IN 2. DMX OUT 3. Sound sensitivity 4. Microphone 5. Connection to SL-FC3 Foot controller (sold separately) 6. IEC Power OUT 7. IEC Power IN (Fuse F1A and F3A for SL-Q12) Caution: At the last fixture, the DMX-cable has to end with a terminator. Solder a 120 Ohm resistor between PIN 2 (-) and PIN 3 (+) into a 3-pin XLR-plug and plug it in the DMX-output of the last fixture. SmartLIGHT User Manual Page 12 SmartLIGHT User Manual Page 9

CONTROL DISPLAY: SECONDARY FUNCTION: 1. MODE\ESC: Menu or withdraw the last menu 2. UP: Increase one step each time 3. DOWN: Decrease one step each time 4. ENTER: Confirms the functions you select *Note the display will turn off if no activity for 20 seconds. A001-A512 DMX-512 Address from 1 to 512 Er_L If there is a breakdown in the DMX connection AUT1 Auto color switch AUT2 Auto color switch, fade in & fade out effect (slow fade in slow fade out) AUT3 WRGB Color Scroll, fade in & fade out (slow fade in quick fade out) AUT4 Auto color mixing, Pastel scroll SOU1 Sound Activated with colour changing mode SOU2 Sound to light strobe all LEDs on. 3 flashes per beat SOU3 Sound to ligtht blast color switch quick fade in slow fade out PRIMARY FUNCTION: MASTER/SLAVE: LED Display Sund AUTO CLOr disp dsip Addr Action Sound to light mode Auto programs Pre-set colours Display normal Inverted display Set DMX address If you have more than one unit you wish to operate the same but do not have a DMX controller or foot controller then you can do so in the following simple way: Connect a 3 pin DMX XLR cable from the DMX OUT socket on the master unit and plug in to the DMX IN socket on the slave device. Then set the Slave device to DMX address to be A001 and it will repeat whatever operation is current on the master unit. This can be repeated for up to 32 fixtures. SmartLIGHT User Manual Page 10 SmartLIGHT User Manual Page 11