MODEL: JUPITER. Instruction Manual

Similar documents
MODEL: JUPITER X. Instruction Manual

MODEL BAC-100 Instructions Manual

Thank you for purchasing an AlcoSense Surety breathalyser.

LE5 Alcohol Tester User Manual

B R E A T H A L Y S E R

Wingmate Rover Components

GPS NAVIGATION SYSTEM 3V1 Hardware Instruction Manual

One (1) acoustic and three (3) seismic channels. Three (3) component velocity output. All units are interchangeable with accuracy within two percent.

Lifeloc FC20. Operations Manual. Unlock the Power of Alcohol Testing

AlcoScan AL3500 [ AL3500FC ] Operating Manual

TRAC TRAC OWNER'S MANUAL. Ver: HW Safe Community Institute

i-hydro 7900 Water Vapor Transmission Rate Testing System

CONTENTS Introduction 4 DTR overview 4 probes 5 functions 5 display 5 DTR operation 6 switching the DTR on or off 6 changing label 6 displaying

C A GA Alle Sprachen / 7 WORD A 4 E 6020 Plus

User manual Model: VIU-800 Brand:

FG-7000 Digital Force Gauge Operation Manual

PTR. printing temperature recorder. User Manual. order code:

ISF-1DF SERIES DIGITAL FORCE GAGE OPERATION MANUAL

DT810 STOPWATCH WITH PRINTER INSTRUCTION MANUAL. BK233 Printed in China 第一頁

6165 MONEY COUNTING SCALE

Handsfree Speaker Kit with Bluetooth Wireless Technology. Instruction Manual Model Number: ABHK-014 AUS

LE5 Breathalyser User Manual

DT800 Lane Timer Manual

Copra Moisture Tester. Operating Manual

CONGRATULATIONS ON YOUR CHOICE

USER MANUAL KGNDVCFVAA

TTC Series Torque Tool Tester Operation Manual

Rechargeable Bluetooth Audio Transmit or Receive Dongle

Introduction Congratulations on your purchase of this digital video camera. Before using the camera, please read this user manual carefully.

FG-7000L Digital Force Gauge Operation Manual

USER GUIDE. Video Particle Counter with built in Camera. Model VPC300

Getting Started. Quick Start: Where to find more information. Steps What to do Purpose. Page 2

Instruction Manual BOOM BARREL MINI MODEL: S29

CO Analyzer. The Value Leader TM

SHIMPO INSTRUMENTS. FG-7000T Digital Torque Gauge Operation Manual

Dräger Alcotest 7510 Alcohol Screening Device

Quick Reference Guide. LabelManager 280

Net-Ritef Continuity and Wiremap Tester Trace-Ritef Tone Generator and Amplified Tone Tracer User's Guide.

I. PANEL DESCRIPTION... 1

English. Instruction and operation manual S 505. Dew point meter (portable)

MW-145BT Mobile Printer

GE A Acoustic Belt Tension Tester. User s Operation Manual

USER GUIDE. Video Particle Counter with built in Camera. Model VPC300

English 1. Package Contents. The package contains the following items. In case there is any missing or damaged item, contact your dealer immediately.

Introduction. Precautions

SmartPOS7. User Manual

1. Review the printer safety information in the Regulatory Compliance document provided with your printer.

LEGO Energy Meter. How to Get Started

SX4M SX5M TXPSX4 TXPSX5

XEMIO-950 MP5 PLAYER / 4GB MEMORY / TOUCH SCREEN. For information and support,

User manual. paper moisture meter humimeter RH5 with sword sensor

USER MANUAL Video Particle Counter with built in Camera Model VPC300

Dräger Alcotest 7510 Evidential Breath Alcohol Measurement

AWS DeepRacer Getting Started Guide

Datalogging RH / Temperature Pen Instruction Manual

Multifunction Calibrator

Stonex Europe S.R.L. S3 Series Quick Start

CALOG CALOG - LC DISPLAY. Loadcell Display. English Users Manual. Rev. 1.10

Model SRV411i Small Animal Floor Scale Service Manual Part No. MANSRV411i_ Page 1 of 16. Small Animal Floor Scale. Operating and Service Manual

Copyright 2013 DOD Tech All Rights Reserved

Copyright 2014 DOD Tech All Rights Reserved

PrintPAD MC65. User Guide

SP-L51. Portable Thermal Printer. User s Manual VER 1.00

QUICK REFERENCE. Using the Battery

GREISINGER electronic GmbH D Regenstauf, Hans-Sachs-Straße 26

Dräger Alcotest 7510 Evidential Alcohol Measuring Device

GPS Vehicle and personal location tracker. User manual

SPECIFICATIONS HAND HELD PARTICLE COUNTER KC Higashimotomachi, Kokubunji, Tokyo , Japan

C F MAX MIN TEMP:-20 C~ 60 C -4 F~140 F HUMIDITY: 0 ~ 100RRH HOLD TIMER T2 T1 RS-232 DC9V. h:m:m:s HUMIDITY TEMPERATURE METER POWER - UP OPTIONS

Field Equipment for Measuring Electrical Conductivity, Humidity and ph of Soil

MANUAL PCE-123

USER MANUAL ENGLISH 285-S COMPACT VALUE COUNTER

Sound Level Meter SD Card real-time Datalogger

Operation Manual Locator Wöhler L 200

Copyright C 2014 DOD Tech All Rights Reserved

Line Interactive 1000VA/1400VA/2000VA Uninterruptible Power System

Please read and retain these instructions for future reference v002: 14/03/17. Cradle, Charger, Instruction manual, Lithium-ion Battery 3.7 V d.c.

acaia lunar Operation Manual

SMARTCOMPANION USER GUIDE PRODUCT SPECIFICATIONS GETTING STARTED STATUS AND DESCRIPTIONS ACTIVATION INSTRUCTIONS

SALA PROSAT GPS Tracking System MS03 User Guide

NEBULA X USER MANUAL. Redefining Tradition. Read carefully before using the device and save these instructions.

The Suntactics PC5 Solar USB Charger

Defibtech DDU-100 Semi-Automatic External Defibrillator

Quick Start Guide. LabelWriter

Label Printer QL-810W/820NWB. Quick Setup Guide (English)

FG-3000R Digital Force Gauge Operation Manual

Xemio-154 User Manual

Owner s Manual v1.0.0

NOVO-GLOSS. Flex 60. Operating Instructions. English

GMC-206/215/230 Digital Desktop Weighing Scale Operation Manual

NHT-310. Broadband EM Field Meter: DC 40 GHz. HAVSCo LTD. Key Features:

WalkLAB HC Professional Conductivity-TDS-Salinity Meter. Operations Manual 15,0,11,4,1,14,5,10,13,2,9,6,3,12,7,8

TEST AND MEASUREMENT SRM 200 SRM 200/EFM 51 STARTERKIT

FG-3000 Digital Force Gauge Operation Manual

TR-101 User Manual. Ver 1.14

1. Introduction 2. Specifications 3. Symbol Definition and Button Location 4. Operation Instructions 5. Temperature Measurement 6.

Magnetic Immunoassay Reader Operator Manual

Vibration Meter SD Card real-time datalogger

PARTS CATALOGUE / TECHNICAL GUIDE Cal. S149A

RS Stock No Instruction Manual RS Input Data Logging Thermometer

Transcription:

MODEL: JUPITER Instruction Manual

TABLE OF CONTENTS STRUCTURES 1 INSTRUMENT FEATURES.. 2 ICON DESCRIPTION 3 INTRODUCTION.. 4 OPERATING INSTRUCTIONS 5 PRINTER 9 TOUCH SCREEN CALIBRATION.. 9

STRUCTURES P. 1 Operator needs to read operation manual and familiar with the operation before using. Retain the manual for future reference.

P. 2 INSTRUMENT FEATURES PLEASE REFER TO DIAGRAME ON PAGE 1 1. DISPOSABLE MOUTHPIECE For sanitary reason, each mouthpiece is individually packed and sealed. New mouthpiece should be attached to sample port for each test to prevent any contamination from the previous sample. 2. SAMPLING CUP Sampling Cup is reusable. Attach sampling cup to the sample port. Do not touch the sampling cup with the mouth while providing a breath sample. Remove the sampling cup after use and clean it by alcohol for next use. 3. BUTTON TO REMOVE MOUTHPIECE For sanitary reason, the mouthpiece can be removed by push the button underneath the mouthpiece. 4. TOUCH SCREEN DISPLAY A touch screen display that will display corresponding instructions and alcohol concentration of the subject being test. Select the icons and buttons on the screen by using the stylus pen provided. 5. ON/OFF BUTTON Press and hold the On/Off button to turn on or turn off the device. 6. BATTERY CHARGING Battery can be charged inside the device. The battery charging indicator turns red when the battery is charging, when the battery is fully charged, the indicator turns green. 7. EXTERNAL POWER CONNECTORS Connectors for 12V car (cigarette) adapter or optional 12V power transformer. Battery can be charged inside the device. 8. USB connector Use an USB cable to upload test records stored in the memory and upgrade the software.

ICON DESCRIPTION P. 3 1 GPS Indicator 8 GPS 2 Battery Indicator 9 PC Connection 3 Date & Time Indicator 10 Date & Time Setting 4 Standard Test with Input 11 Setting 5 Standard Test without Input 12 Advanced Setting 6 Screening Test 13 Last Calibration Date 7 Test Records 14 Test Record Counter Previous Screen/Cancel Next Screen/Confirm Main Screen Print Repeat Test

P. 4 INTRODUCTION It is a state of the art instrument used to detect Ethyl Alcohol from a valid breath sample. It uses an electrochemical fuel cell to measure the concentration of alcohol from the sample of the expired breath from a human subject. If alcohol is present, a corresponding voltage is generated from the fuel cell, which is proportional to the alcohol content of the sample provided by a human subject. This voltage is then sent to the CPU and converted to a subject s BAC which is then displayed. Instrument Features: 1. Test record storage is more than 32,000 entries depending on the length of the records being stored. Capability of uploading test records for record keeping. 2. Use disposable mouthpieces or sampling cups to prevent foreign matter from entering. 3. A hard plastic case is included for storing the device and accessories for easy transport. When not in use, the device and accessories should be stored in this plastic case to prevent damage. 4. Ability to run as often as needed. Recovery time between tests on average is 30 seconds between positive tests. 5. Powered by High-capacity lithium battery. Battery is located behind the sliding cover on the back of the device. The level of power left in the battery is indicated on the screen. A cigarette plug adapter is also included for use by the operator. 6. Storage temperature range is -25 C to 70 C, storage humidity is 15% to 90%, inappropriate storage of the device will shorten the lifespan of the fuel cell sensor.

OPERATING INSTRUCTIONS P. 5 Pre-test Conditions 1. Operating temperature range is -10 C to 50 C. Use within this temperature range will limit condensation from a subject breath to insure an accurate an accurate reading from a breath sample. 2. It is recommended that the operator to observe a subject for about 20 minutes before administering the breath test to insure that nothing is consumed or expelled from the mouth of the subject. Following this procedure will eliminate reading from mouth alcohol. Standard Test with Input 1. Attach a disposable mouthpiece onto the sample port. 2. Input information by a stylus pen. NOTE: Maximum 16 characters for each input. 3. When displays Please Blow, take a deep breath and blow until BEEP tone stops. 4. Test result displays on the display. 5. Select to print the test result. 6. Select to start another test. 7. If testee did not blow within 30 seconds, tester can select Refuse to confirm the testee refused to do the test; or select Test Again to allow testee to do the test again. 8. If testee failed to give a valid breath sample, tester can select Discontinue to confirm; or select Test Again to allow testee to do the test again. 9. A passive test can be performed by select Passive during the testee is blowing. 10. Push the button underneath the mouthpiece to remove the mouthpiece.

P. 6 Standard Test without Input 1. Attach a disposable mouthpiece onto the sample port. 2. Follow steps 3-10 of Standard Test with Input. Screening Test 1. Attach a sampling cup onto the sample port. 2. When displays Please Blow, take a deep breath and blow to the sampling cup until BEEP tone stops. 3. Alcohol Detected or No Alcohol displays on the display. 4. A passive test can be performed by select Passive during the testee is blowing. 5. Select to start another test. 6. If Alcohol Present, use mouthpiece to perform a standard test to obtain an accurate test result with reading. NOTE: Screening Test is only used for screening tests, it is to check whether alcohol is found in the breath sample. An accurate test result can only be obtained by standard test. NOTE: Test records of the screen tests cannot be printed nor stored. GPS 1. Longitude and Latitude of location of the device will be shown. 2. Longitude and Latitude of the test is stored and printed on the printout. NOTE: GPS system only functioned 5-10 minutes after turn on the device. It can only receive signal in open area. If there is no GPS signal, the Longitude and Latitude will not be shown on the printout.

P. 7 Test Record 1. Over 20,000 test records can be stored, depending on the length of the records. 2. Individual test record can be printed by selecting. 3. Use or to move to the previous or next record. 4. Press On/Off button (right button) to move 10 records forward, and press Function button (left button) to move 10 records backward. 5. Press On/Off button (right button) and Function button (left button) together to jump to the record needed. First: Jump to first Record End: Jump to end Record 0 00 00: Jump to a specific record, e.g. 0 01 00 means jump to record 100; 1 12 00 means jump to record 11200. Connect to PC 1. Test records can be downloaded PC for analysis. 2. Connect the device and the PC by a USB cable. 3. Please refer to Database Instruction for downloading the test records. Date & Time Setting 1. Set correct Date and Time. 2. Select Update to confirm.

P. 8 Setting 1. Auto Off i. Select time limit to turn off the device automatically. ii. Select to confirm 2. Print i. Select Auto Print to print the result automatically after each test without selecting Print. ii. Select number of printout copies needed for test result equal to 0 ( =0 ) and exceed 0 ( >0 ). iii. Select to confirm. NOTE: If no printout needed for a test result equal to 0, select 0 for =0. 3. Sound i. Adjust the level of BEEP tone. First bar: sound level of BEEP tone. Second bar: length of the BEEP tone. ii. Select to confirm. 4. Cali i. When the screen displays Calibration Needed, send the device for calibration. ii. A password is needed for calibration to ensure calibration is performed by eligible persons. iii. Please refer to Calibration Instruction. Advanced Setting 1. Only legitimated persons are allowed for advanced setting. 2. A Password is needed. 3. Please refer to Advanced Setting Instruction.

PRINTER P. 9 An attachable built-in thermal printer is used for the device. INSERT PAPER Pull the handle to open the printer cassette and inset thermal paper. When inserting a new roll of paper, ensure glossy side of the paper is kept close to dentation. NOTE: If nothing can be printed, change the side of the paper and try again. STANDARD TERMAL PAPER SIZE 6cm X 500cm TOUCH SCREEN CALIBRATION If the touch screen is not sensitive enough, please calibrate the screen. Press and hold the On/Off button (right button) and then press the Function button (left button) immediately. Follow the instruction on the screen to calibrate the screen.