Raptor Remote Trigger Option Application Note Version 1.12

Similar documents
UndercoverEye QTI-Raptor Product Data Sheet

PixController, Inc. UndercoverEye Raptor Camera System

PixController, Inc. UndercoverEye Raptor Camera System

Camtraptions Multi Cable for Sony

PixController, Inc. Wireless Switch Sensor For Normally Open (NO) and Normally Closed (NC) Sensors

Innovative Electronics for a Changing World. Charge Smart R1 MPPT 12V/24V Auto detect Mains and Solar Battery charger with Remote Network Monitoring

12v Power Controller Project Board


SMART SHOT CONTROLLER FLUID USERS GUIDE

SMART HOME SYSTEMS. Group 10. Daniel Moody CpE Thien Luu EE Joel LeGros EE Vu Ha EE

See it. Control it. The TelPro Solution

1. Creating a TRUPHONE account and Activating your SIM card 2. Creating your myspypoint account CANADA/TELUS. TRUPHONE/MYSPYPOINT v1.

INDEX. Network Power Monitor NPM-R10-SNMP. Innovative Electronics for a Changing World. NPM-R10-SNMP Remote Network Power Monitor

PixController, Inc. Wireless Magnetic Switch Sensor For Doors, Windows, and Gates

EZY SWITCH. SMS-8 System Monitor Installation Manual Applicable for firmware version 1.1 or above

Integriti 8-32 Zone LAN Expander Module Kit INSTALLATION MANUAL

USER GUIDE. Security Multi-Sensor

Hidden Camera Surveillance

The Next Generation in Law Enforcement Surveillance

SMS Power Controller. User Documentation. V Feb

IoTECH* *Internet of Things Extensible Car Hub. MDR Presentation

EnCell Battery Cell Monitor

Gate-Keeper instructions

Haas GPS. Personal Auto Management System Text-N-Track H1000 READ THIS GUIDE BEFORE YOUR FIRST INSTALLATION

CAMERA CHARACTERISTICS

Please refer to the guide below to use the latest version of the ios UCam247Live app.

Embedded Solution IT Solution Industrial Automation

UndercoverEye Power Box Instruction Manual

IoTECH* *Internet of Things Extensible Car Hub. PDR Presentation

G G receiver with relay output for opening sliding, swing gates, doors or switching devices

Technical Support option 2

ipcam-wo Wireless Outdoor

x x 60 mm, 700 gm. Wall mounted enclosure, 1 Kg. Weatherproof, high impact GF ABS. Remote control and monitoring with debug features

GSM BATTERY POWERED AUTO DIALLER

Introduction. See page #6 for device requirements.

629/P32 (X10/P32) PIC CHIP. On - Off Operating Instructions (Revision 2)

KWJ-WSN & USB Gateway. Quick Start Guide

Product Catalog. senseware.co Tysons Boulevard Floor 5 Tysons VA, 22102

GSM AUTO DIALER WITH IR BEAM DETECTOR

Instructions for I40XT GameSpy Digital Camera

2009 FRC Control System. Published by Team 103

Open gates & doors with your mobile phone.

Camtraptions PIR Motion Sensor v3 Manual. Firmware Version 2.2

Sensus T866 MicroRTU. Remote Input/Output Control. Applications. Reporting Methods DATA SHEET

Fixturlaser SMC Supervisor QUICK TIPS. Fixturlaser SMC

FAST Installation (PMRS) Box Contents

Glu Home, Smart Home!

truvision DVR 31 Quick Start Guide

SPEEDALERT 18 RADAR MESSAGING SIGN

Spartan GoCam Cellular Camera Trap QUICK START GUIDE. (sending via MMS / ) (4G/LTE/3G/2G) Backwards compatible 3G and 2G

Software Requirements Specification. Smart Doorbell. for. Version 1.0 approved. Prepared by Shriya Shah & Umang Ajmera LDRP-ITR

INDEX. Network Power Monitor R10 SNMP

Innovative Electronics for a Changing World. NPM-R10 Remote Network Power Monitor. With optional relay board and GSM module INDEX

Blue Point Engineering

Camtraptions PIR Motion Sensor Manual. Firmware Version 2.1

PicoBoo AC. OPERATING MANUAL V1.1 (Sep 8, 2011) 6 Oakside Court Barrie, Ontario L4N 5V5 Tel: or

DAS 250L CONTROL COMMUNICATOR INSTALLATION MANUAL

Secure Your Way of Life. Now Compa ble With. HSVGW-G Series Home Security Voice Gateway Series. Take Smart Living Up a Notch

Automate Pulse Set-Up Instructions

Motion Activated Camera

HOW TO INSTALL E-LD TO E-xD USING CONNECTION TO USB CONSOLE

How to build an Olympus D-360L Trail Camera using the PixController Universal "Digital Trail Camera Kit" w/ RS-232-U PIC Chip

The Lumina has an astronomical clock and automatically adjusts for daylight savings time in order to provide accurate dusk to dawn lighting control.

GSM TEMPERATURE ALARM DIALLER

Home Monitoring and Control service provided by Verizon Online LLC

The Otto Home Control app allows for control of your motorized window coverings through your smartphone/tablet

Product Specification SpeedAlert 18 Radar Message Sign

DIGITAL GAME CAMERA. Model DC-6SS

Remote VideoEye Instruction Manual

5.1 Configure each Sensor Pin Rename Set Rules Export Data Switching Nodes... 25

SecurityProbe 5E Camera & Alerting Setup Manual

PS-4100 POWER SUPPLY MANUAL

hiotron Smart Home Automation Kit

Relay Configuration Form * Required

Unique. S afety & ecurity olution. Utmost Safety with Exceptional Technology

INTRODUCTION TABLE OF CONTENTS 1 INTRODUCTION WELCOME TO THE 2009 FRC CONTROL SYSTEM Suggestions for Getting Started 2

S911 Bracelet Firmware and Utility. Release Note

Installation Guidelines for KODAK SA101 Alarm System

Setup and Activation Guide for the TravelNet Data/Voice Terminal

SMART HOME SYSTEMS. Group 10. Daniel Moody CpE Thien Luu EE Joel LeGros EE Vu Ha EE

CRAGG RAILCHARGER Instruction Manual for 10DTC-12V 20DTC-12V 30DTC-24V 40DTC-12V 60DTC-12V

Portable Work Zone Data Collection. Blaine Van Dyke ODOT ITS Designer

Accelerated Concepts Cellular Extender

SHIELD RADAR SPEED DISPLAY

D3D Security Pvt ltd

EPUB // SAMSUNG GALAXY 7500 ONLINE MANUAL DOWNLOAD

The ICU-Duino Arduino Shield!

How to hardwire the Sony DSC-P32 Digital Camera

CAM-KIT6. User Manual. Connects2Vision. Mirror with DVR & Rear Camera PRODUCT FEATURES:

CONTROL4 INTEGRATION WITH THE SHADE STORE MOTORS CONTROL4 INTEGRATION OVERVIEW:

Product Manual SSR Relay Board

TruVision DVR 30 Quick Start Guide

HP8440 Power Box. The Intelligent Power Distribution Module. Installation and User Guide for PCM Version 9.02

DOWNLOAD OR READ : VERIZON LG DARE USER MANUAL PDF EBOOK EPUB MOBI

Intelligent infrastructure monitoring for software-defined data centers. Intelligent Power Manager Infrastructure Simplified IT-centric monitoring

GL-104 ENCODER/DECODER MANUAL GLOLAB CORPORATION

Door/Window Sensor. Set-Up Guide

+ Front Door Security + Smart Video Alarms + Indoor Cameras + Personal Trackers SOLUTIONS FOR SMART & SAFE HOMES

SMM501/501-H (Surveillance Mode Module) Ford Police Interceptors (Sedan and SUV)

BACnet. b3810 Series Local Controllers

Transcription:

Raptor Remote Trigger Option Application Note Version 1.12 PixController, Inc. 1056 Corporate Lane Export, PA Phone: 724-733-0970 Web: www.pixcontroller.com

Introduction The PixController Remote Trigger Option is a special feature of our popular Raptor Wireless Camera System. This option allows a user to connect an external 12V solenoid or 12V relay for momentary trigger control of gates or live animal traps. This Application Note will cover the uses of feral hog and selective wildlife trapping, but this same application can be applied to access control such as remote gate control. The PixController, Inc. Remote Trigger Option requires the PixController Raptor Wireless Camera system with the External Device Port option and Remote Trigger or Peripheral cable. This option also requires Raptor Firmware V3.54a and PC Raptor Config software V2.06 or later. Raptor Firmware and PC Raptor Config software can be downloaded on our website at: http://www.pixcontroller.com/downloads.htm Raptor Remote Trigger Option The Raptor Remote Trigger systems incorporates a remotely monitored wireless camera which alerts the user in real-time when an animal has entered the trap. With the photo transmitted by the remote camera the user can determine if this is an animal of interest at the trap site. Once the determination has been made the user can remotely trigger the trap door to close by sending a SMS text command to the Raptor Remote Trigger system. The uses can also send SMS text commands to remotely trigger a manual photo or to disable the camera system from sending further photos after the trap trigger SMS command has been sent. The ability of a user to determine when to trigger the trap can be a major advantage over the much more indiscriminate manually activated animal traps or standard animal-triggered live traps. The Raptor Remote Trigger system will momentarily send a 0V to 12V transition pulse for 5 seconds when sent the SMS trigger command. The system can support solenoids up to 40 Amp draw using the included Raptor Trigger Cable Assembly part number CAB-030. For designs requiring solenoids over this current specification the user must wire a relay into the circuit. Please refer to the wiring diagram below. Raptor Config File Settings Before the Raptor Remote Trigger system can be deployed you must set up the Raptor USB Flash using the RaptorConfig.exe PC application. Remove the USB Flash drive from the Raptor camera and run the RaptorConfig.exe PC application.

Config Settings Change 1 Go to the COTA tab and select the One Minute Camera Update Cycle. Config Settings Change 2 Next, go to the Camera tab and select the Fixed option and enter a time of 1 minute or greater under the Video Clip Acquisition settings. The One Minute COTA option will tell the Raptor to wait the delay in minutes/seconds after a photo is taken. This will keep the Raptor in a mode waiting for a SMS text message to come in to trigger the solenoid. Keep in mind that the longer you make this delay the more battery power the Raptor system will use.

Example Field Deployment Figure 1 Figure 1 shows a typical use of the Raptor Remote Trigger in a live animal trap deployment scenario. This set up shows a common live trapping system with the trap trigger system modified to use a solenoid trigger. When the animal enters the live trap it will activate the Raptor wireless camera to take a photo. When the user receives the photo they can send a SMS text command back to the raptor to trigger the solenoid and close the live trap. The same type of set up can be use to catch feral hogs. When trapping feral hogs or larger animals the user must construct a pen system with a gate for the animal to enter. The solenoid trigger system will control closing the gate. For this type of set up a larger solenoid may need to be used and the installer will need to trigger the larger solenoid with a relay. Please refer to the wiring diagram below. When trapping larger animals such a feral hogs we recommend using the wireless sensor option for the Raptor wireless camera. This will allow the user to place the camera in a different location from the motion sensor. Multiple wireless motion sensors can be used. Feral hog trapping application

Example Raptor Photo Notification When Raptor wireless camera is activated by the animal it will send the photo in real-time to the programmed email and smart phone address. Figure 2 below shows an example of the notification sent. In this notification you will receive the Raptor Device Phone Number. You will to use this phone number to send SMS commands to the Raptor Remote Trigger system from your cell phone. From: Raptor@PixController.com [mailto:raptor@pixcontroller.com] Sent: Wednesday, July 30, 2014 3:08 PM To: myemail@address.com; 2315551212@cellprovider.com Subject: Live Trapping Test Camera 1 Camera Description: Live Trapping Test Camera Trigger Date: Tue, 01 Jul 2014 Trigger Time: 15:07:56-0400 Trigger Source: Built-in PIR Since last start: 1 triggers, 1 transmitted Signal Strength: Fair (2/5) Cellular Operator: Verizon (32) Raptor Device Phone Number: 7245559222 Raptor Device MEID Number: E100003299E48B Battery Level: 68% (12.3 volts) Filename on flash drive: \PIX\IMAGES\00000\11563951.jpg Attachment Filename: Cam00_20140701_150756.jpg *** This e-mail auto-generated by the PixController Raptor V3.54a *** Figure 2

How to Trigger Trap via SMS Commands Step 1 We recommend sending photos from the Raptor Remote Trigger system to your smart phone. When the Raptor system is triggered you will receive a photo in real-time to your smart phone. If you see the desired animal you want to trap send a SMS text message of 40 to the Raptor phone number. This will close the trigger system. Send SMS text 40 to trigger trap Step 2 If you want to verify you have caught the animal send the SMS text message of 10 to the Raptor phone number. This will send a manual photo trigger command. Note: This step is not needed. Typically the animal in the trap will trigger the motion sensor after being trapped if the motion sensor is pointed into the trap area. Step 3 If you wish to disable any further motion events from the Raptor camera after the animal is trapped send the SMS text message of 50 to the Raptor phone number. This will disable the Raptor motion sensor. To enable the Raptor motion sensor send the SMS text message of 51 to the Raptor phone number. Send SMS text 10 to capture a manual photo Send SMS text 50 to disable Raptor motion sensor Send SMS text 51 to enable Raptor motion sensor Video Example For a video example of the Raptor Remote Trigger capturing a raccoon please see our YouTube video here: http://www.youtube.com/watch?v=gzjvuwjcoby

Example Wiring Diagram The Raptor Remote Trigger Cable (part number CAB-030) requires the customer to wire a solenoid for triggering a gate system. This section will cover the steps in wiring a solenoid to your Remote Trigger Cable. Step 1: Remove the red wire from the Remote Trigger Cable system as shown in Figure 3 Figure 3 Step 2: Wire a solenoid and 12V Sealed Lead Acid (SLA) battery to the Remote Trigger Cable system as show in Figure 4. Be sure your solenoid is rated for 40 AMP current draw or less. Figure 4