SERIES L: CONSTRUCTION, INSTALLATION AND PROTECTION OF CABLES AND OTHER ELEMENTS OF OUTSIDE PLANT

Similar documents
I n t e r n a t i o n a l T e l e c o m m u n i c a t i o n U n i o n

Technical Requirements for High-voltage DC Power Feeding Interfaces of ICT equipment

SERIES G: TRANSMISSION SYSTEMS AND MEDIA, DIGITAL SYSTEMS AND NETWORKS Digital terminal equipments General

ITU-T Y Next generation network evolution phase 1 Overview

SERIES G: TRANSMISSION SYSTEMS AND MEDIA, DIGITAL SYSTEMS AND NETWORKS Access networks In premises networks

ITU-T H.323. Amendment 1 (03/2013) Packet-based multimedia communications systems Amendment 1: Use of Facility message to enable call transfer

SERIES H: AUDIOVISUAL AND MULTIMEDIA SYSTEMS Infrastructure of audiovisual services Communication procedures

ITU-T. G.870/Y.1352 Amendment 1 (11/2009) Terms and definitions for optical transport networks (OTN) Amendment 1

ITU-T J.288. Encapsulation of type length value (TLV) packet for cable transmission systems

ITU-T L Energy efficiency metrics of a base station site

ITU-T. P.10/G.100 Amendment 3 (12/2011)

SERIES G: TRANSMISSION SYSTEMS AND MEDIA, DIGITAL SYSTEMS AND NETWORKS Digital networks Quality and availability targets

ITU-T G.979. Characteristics of monitoring systems for optical submarine cable systems

ITU-T Q Signalling architecture and requirements for IP-based short message service over ITU-T defined NGN

SERIES M: TELECOMMUNICATION MANAGEMENT, INCLUDING TMN AND NETWORK MAINTENANCE Telecommunications management network

ITU-T K.118. Requirements for lightning protection of fibre to the distribution point equipment SERIES K: PROTECTION AGAINST INTERFERENCE

SERIES M: TELECOMMUNICATION MANAGEMENT, INCLUDING TMN AND NETWORK MAINTENANCE Telecommunications management network

SERIES Q: SWITCHING AND SIGNALLING Signalling requirements and protocols for the NGN Service and session control protocols supplementary services

SERIES G: TRANSMISSION SYSTEMS AND MEDIA, DIGITAL SYSTEMS AND NETWORKS Digital networks Design objectives for digital networks

ITU-T I.570. Public/private ISDN interworking. SERIES I: INTEGRATED SERVICES DIGITAL NETWORK Internetwork interfaces. Recommendation ITU-T I.

ITU-T G (07/2010) Gigabit-capable passive optical networks (GPON): Long reach

INTERNATIONAL TELECOMMUNICATION UNION

SERIES H: AUDIOVISUAL AND MULTIMEDIA SYSTEMS Infrastructure of audiovisual services Coding of moving video

SERIES G: TRANSMISSION SYSTEMS AND MEDIA, DIGITAL SYSTEMS AND NETWORKS Digital sections and digital line system Metallic access networks

ITU-T G.672. Characteristics of multi-degree reconfigurable optical add/drop multiplexers

ITU-T. G.8271/Y.1366 Amendment 1 (08/2013) Time and phase synchronization aspects of packet networks Amendment 1

INTERNATIONAL TELECOMMUNICATION UNION

INTERNATIONAL TELECOMMUNICATION UNION

SERIES L: CONSTRUCTION, INSTALLATION AND PROTECTION OF CABLES AND OTHER ELEMENTS OF OUTSIDE PLANT

ITU-T G.657. Amendment 1 (06/2010)

SERIES J: CABLE NETWORKS AND TRANSMISSION OF TELEVISION, SOUND PROGRAMME AND OTHER MULTIMEDIA SIGNALS Digital transmission of television signals

ITU-T X.282. Superseded by a more recent version. Amendment 2 (12/97)

INTERNATIONAL TELECOMMUNICATION UNION

ITU-T D.115. Tariff principles and accounting for the International Freephone Service (IFS)

SERIES X: DATA NETWORKS, OPEN SYSTEM COMMUNICATIONS AND SECURITY. ITU-T X.660 Guidelines for using object identifiers for the Internet of things

ITU-T G.7712/Y Architecture and specification of data communication network. Amendment 2

SERIES X: DATA NETWORKS, OPEN SYSTEM COMMUNICATIONS AND SECURITY Secure applications and services Security protocols

ISO/IEC INTERNATIONAL STANDARD. Information technology Abstract Syntax Notation One (ASN.1): Information object specification

ITU-T. G Amendment 1 (06/2011) Improved impulse noise protection for DSL transceivers Amendment 1

Gigabit-capable Passive Optical Networks (G-PON): Physical Media Dependent (PMD) layer specification Amendment 2

INTERNATIONAL TELECOMMUNICATION UNION

SERIES H: AUDIOVISUAL AND MULTIMEDIA SYSTEMS Infrastructure of audiovisual services Communication procedures

INTERNATIONAL TELECOMMUNICATION UNION

ISO/IEC INTERNATIONAL STANDARD

INTERNATIONAL TELECOMMUNICATION UNION. SERIES H: AUDIOVISUAL AND MULTIMEDIA SYSTEMS Infrastructure of audiovisual services Communication procedures

Information technology Security techniques Telebiometric authentication framework using biometric hardware security module

ISO/IEC INTERNATIONAL STANDARD. Information technology Abstract Syntax Notation One (ASN.1): Parameterization of ASN.

ITU-T. G.8013/Y.1731 Amendment 1 (05/2012) OAM functions and mechanisms for Ethernet based networks Amendment 1

ITU-T E.212. The international identification plan for mobile terminals and mobile users

ITU-T G /Y

INTERNATIONAL TELECOMMUNICATION UNION. Signalling system No. 7 ISDN user part enhancements for the support of number portability

ISO/IEC INTERNATIONAL STANDARD. Information technology ASN.1 encoding rules: Specification of Octet Encoding Rules (OER)

SERIES Q: SWITCHING AND SIGNALLING Testing specifications Testing specifications for next generation networks

SERIES E: OVERALL NETWORK OPERATION, TELEPHONE SERVICE, SERVICE OPERATION AND HUMAN FACTORS

ITU-T Y Adaptive software framework for Internet of things devices

ITU-T G Gbit/s point-to-point Ethernet-based optical access system

ITU-T G Amendment 3 (10/2012) The control of jitter and wander within the optical transport network (OTN) Amendment 3

SERIES E: OVERALL NETWORK OPERATION, TELEPHONE SERVICE, SERVICE OPERATION AND HUMAN FACTORS Network management International network management

ITU-T Y Protection switching for MPLS networks

SERIES H: AUDIOVISUAL AND MULTIMEDIA SYSTEMS Infrastructure of audiovisual services Communication procedures

ITU-T Q.1970 TELECOMMUNICATION STANDARDIZATION SECTOR OF ITU

Final draft ETSI EN V2.1.1 ( )

INTERNATIONAL TELECOMMUNICATION UNION. SERIES I: INTEGRATED SERVICES DIGITAL NETWORK B-ISDN equipment aspects Multiplexing aspects

T.140 (02/98) Protocol for multimedia application text conversation SERIES T: TERMINALS FOR TELEMATIC SERVICES. ITU-T Recommendation T.

INTERNATIONAL TELECOMMUNICATION UNION

ITU-T Q Recommendation ITU-T Q.3229 (08/2016) I n t e r n a t i o n a l T e l e c o m m u n i c a t i o n U n i o n

INTERNATIONAL TELECOMMUNICATION UNION. SERIES G: TRANSMISSION SYSTEMS AND MEDIA, DIGITAL SYSTEMS AND NETWORKS Digital networks General aspects

ITU-T Y IP access network architecture

ITU-T T.81. Corrigendum 1

ITU-T. G.8013/Y.1731 Amendment 1 (02/2015) OAM functions and mechanisms for Ethernet based networks

ITU-T Y Requirements of smartphone as sink node for IoT applications and services

Drafting Recommendations. Gary Fishman Pearlfisher International

ITU-T G.832. Transport of SDH elements on PDH networks Frame and multiplexing structures

ISO/IEC INTERNATIONAL STANDARD. Information technology ASN.1 encoding rules: Mapping W3C XML schema definitions into ASN.1

SERIES G: TRANSMISSION SYSTEMS AND MEDIA, DIGITAL SYSTEMS AND NETWORKS Digital networks Optical transport networks

INTERNATIONAL TELECOMMUNICATION UNION SERIES Q: SWITCHING AND SIGNALLING

INTERNATIONAL TELECOMMUNICATION UNION

INTERNATIONAL TELECOMMUNICATION UNION

INTERNATIONAL TELECOMMUNICATION UNION. SERIES G: TRANSMISSION SYSTEMS AND MEDIA, DIGITAL SYSTEMS AND NETWORKS Quality of service and performance

ITU-T. Series G Supplement 56 (07/2015) OTN Transport of CPRI signals SERIES G: TRANSMISSION SYSTEMS AND MEDIA, DIGITAL SYSTEMS AND NETWORKS

SERIES H: AUDIOVISUAL AND MULTIMEDIA SYSTEMS Infrastructure of audiovisual services Communication procedures

INTERNATIONAL TELECOMMUNICATION UNION

ITU-T Y Overview of ubiquitous networking and of its support in NGN

SERIES L: CONSTRUCTION, INSTALLATION AND PROTECTION OF CABLES AND OTHER ELEMENTS OF OUTSIDE PLANT

ITU-T F (03/2017) Functional requirements for virtual content delivery networks

INTERNATIONAL TELECOMMUNICATION UNION

SERIES Q: SWITCHING AND SIGNALLING

SERIES G: TRANSMISSION SYSTEMS AND MEDIA, DIGITAL SYSTEMS AND NETWORKS. Optical transport network module framer interfaces

INTERNATIONAL TELECOMMUNICATION UNION

INTERNATIONAL TELECOMMUNICATION UNION

ITU-T T.851. ITU-T T.81 (JPEG-1)-based still-image coding using an alternative arithmetic coder SERIES T: TERMINALS FOR TELEMATIC SERVICES

SERIES X: DATA NETWORKS, OPEN SYSTEM COMMUNICATIONS AND SECURITY Telecommunication security. Technical framework for countering spam

INTERNATIONAL TELECOMMUNICATION UNION

SERIES Q: SWITCHING AND SIGNALLING Testing specifications Testing specifications for next generation networks

ITU-T Y Roadmap for the quality of service of interconnected networks that use the Internet protocol

ITU-T Y Framework of multi-homing in IPv6-based NGN

ITU-T G.8001/Y.1354 (07/2011) Terms and definitions for Ethernet frames over transport

ITU-T Y Framework of multi-homing in IPv6-based NGN

SERIES X: DATA NETWORKS, OPEN SYSTEM COMMUNICATIONS AND SECURITY Cyberspace security Countering spam

Standards Update Notice (SUN) Issued: August 11, 2017

Transcription:

International Telecommunication Union ITU-T L.1200 TELECOMMUNICATION STANDARDIZATION SECTOR OF ITU (05/2012) SERIES L: CONSTRUCTION, INSTALLATION AND PROTECTION OF CABLES AND OTHER ELEMENTS OF OUTSIDE PLANT Direct current power feeding interface up to 400 V at the input to telecommunication and ICT equipment Recommendation ITU-T L.1200

Recommendation ITU-T L.1200 Direct current power feeding interface up to 400 V at the input to telecommunication and ICT equipment Summary Recommendation ITU-T L.1200 specifies the direct current (DC) interface between the power feeding system and ICT equipment connected to it. It also describes normal and abnormal voltage ranges, and immunity test levels for ICT equipment to maintain the stability of telecommunication and data communication services. The specified interface is operated from a DC power source of up to 400 V to allow increased power consumption and equipment power density, in order to obtain higher energy efficiency and reliability with less material usage than using a lower voltage such as 48 VDC or AC UPS power feeding solutions. History Edition Recommendation Approval Study Group 1.0 ITU-T L.1200 2012-05-29 5 Keywords Data centre, direct current, energy efficiency, ICT equipment, power feeding system, reliability, telecommunication centre. Rec. ITU-T L.1200 (05/2012) i

FOREWORD The International Telecommunication Union (ITU) is the United Nations specialized agency in the field of telecommunications, information and communication technologies (ICTs). The ITU Telecommunication Standardization Sector (ITU-T) is a permanent organ of ITU. ITU-T is responsible for studying technical, operating and tariff questions and issuing Recommendations on them with a view to standardizing telecommunications on a worldwide basis. The World Telecommunication Standardization Assembly (WTSA), which meets every four years, establishes the topics for study by the ITU-T study groups which, in turn, produce Recommendations on these topics. The approval of ITU-T Recommendations is covered by the procedure laid down in WTSA Resolution 1. In some areas of information technology which fall within ITU-T's purview, the necessary standards are prepared on a collaborative basis with ISO and IEC. NOTE In this Recommendation, the expression "Administration" is used for conciseness to indicate both a telecommunication administration and a recognized operating agency. Compliance with this Recommendation is voluntary. However, the Recommendation may contain certain mandatory provisions (to ensure, e.g., interoperability or applicability) and compliance with the Recommendation is achieved when all of these mandatory provisions are met. The words "shall" or some other obligatory language such as "must" and the negative equivalents are used to express requirements. The use of such words does not suggest that compliance with the Recommendation is required of any party. INTELLECTUAL PROPERTY RIGHTS ITU draws attention to the possibility that the practice or implementation of this Recommendation may involve the use of a claimed Intellectual Property Right. ITU takes no position concerning the evidence, validity or applicability of claimed Intellectual Property Rights, whether asserted by ITU members or others outside of the Recommendation development process. As of the date of approval of this Recommendation, ITU had not received notice of intellectual property, protected by patents, which may be required to implement this Recommendation. However, implementers are cautioned that this may not represent the latest information and are therefore strongly urged to consult the TSB patent database at http://www.itu.int/itu-t/ipr/. ITU 2012 All rights reserved. No part of this publication may be reproduced, by any means whatsoever, without the prior written permission of ITU. ii Rec. ITU-T L.1200 (05/2012)

Table of Contents Page 1 Scope... 1 2 References... 1 3 Definitions... 2 3.1 Terms defined elsewhere... 2 3.2 Terms defined in this Recommendation... 2 4 Abbreviations and acronyms... 2 5 Conventions... 2 6 DC power feeding interface specification... 2 6.1 Definition of DC power feeding interface... 3 6.2 Voltage range at interface P... 3 6.3 Reference test voltage (U T ) at interface P... 4 6.4 Abnormal conditions... 4 6.5 Inrush current... 7 Appendix I Information on grounding method... 8 I.1 Basic configuration... 8 I.2 Specification for PE at interface P... 8 Bibliography... 10 Rec. ITU-T L.1200 (05/2012) iii

Introduction This Recommendation specifies a power feeding system for ICT equipment with a DC voltage of up to 400 V. This Recommendation takes into consideration the improvements in energy efficiency as well as the reduction in greenhouse gas (GHG) emissions and raw materials that are enabled by using the 'up to 400 VDC' power feeding system. The 'up to 400 VDC' power feeding system was developed, due to increased power consumption and equipment power density, in order to obtain a higher energy efficiency with less material consumption than using a lower voltage such as 48 VDC or AC UPS power feeding solutions. One of the advantages of 'up to 400 VDC' power feeding is that it reduces intermediate power conversion stages (e.g., the inverter and power factor compensator can be eliminated) and it is lower current usage than 48 V feeding for the same power requirement, thereby improving the efficiency and reliability of the entire power feeding system. This Recommendation is concerned with the requirements for the interface between the power feeding system and telecommunication and ICT equipment. It also includes requirements relating to its stability, safety and measurement. Reliability and scalability are easier to improve in DC compared to AC because phase synchronization and inverters are not required. The system architecture is also simpler. The purpose of the 'up to 400 VDC' interface is to facilitate interworking of different loads, standardization of power feeding systems for ICT equipment, and installation, operation and maintenance of ICT equipment and systems with different origins. In addition, the DC interface can also simplify the use of renewable energy power sources with DC output such as photovoltaic generators and fuel cell systems. iv Rec. ITU-T L.1200 (05/2012)

Recommendation ITU-T L.1200 Direct current power feeding interface up to 400 V at the input to telecommunication and ICT equipment 1 Scope This Recommendation is aimed at providing compatibility between the power feeding system and ICT equipment installed at telecommunication centres, data centres and customer premises. This Recommendation deals with the requirements for an up to 400 VDC interface between power feeding system and ICT equipment. This Recommendation covers the following main items: The identification of a power feeding system with the same characteristics for all ICT equipment defined in any location where an up to 400 VDC interface is used, e.g., telecommunication centres, radio base stations, data centres and customer premises. The 'up to 400 VDC' voltage range in normal and abnormal service conditions at the interface defined in this Recommendation. Behaviour during voltage variation, dips, short interruptions, transients, inrush current, grounding, etc. The general requirements for safety and earthing and bonding are out of the scope of this Recommendation unless specific requirements are not defined in current standards. 2 References The following ITU-T Recommendations and other references contain provisions which, through reference in this text, constitute provisions of this Recommendation. At the time of publication, the editions indicated were valid. All Recommendations and other references are subject to revision; users of this Recommendation are therefore encouraged to investigate the possibility of applying the most recent edition of the Recommendations and other references listed below. A list of the currently valid ITU-T Recommendations is regularly published. The reference to a document within this Recommendation does not give it, as a stand-alone document, the status of a Recommendation. [IEC 60445] IEC 60445 (2010), Basic and safety principles for man-machine interface, marking, and identification Identification of equipment terminals, conductor terminations, and conductors. [IEC 61000-4-5] IEC 61000-4-5 (2005), Electromagnetic compatibility (EMC) Part 4-5: Testing and measurement techniques Surge immunity test. [IEC 61000-4-29] IEC 61000-4-29 (2000), Electromagnetic compatibility (EMC) Part 4-29: Testing and measurement techniques Voltage dips, short interruptions and voltage variations on d.c. input power port immunity tests. [ETSI EN 300-132-3-1] ETSI EN 300-132-3-1 (2012), Environmental Engineering (EE); Power supply interface at the input to telecommunications and datacom (ICT) equipment; Part 3: Operated by rectified current source, alternating current source, or direct current source up to 400 V subpart 1: direct current (DC) up to 400 V solution. Rec. ITU-T L.1200 (05/2012) 1

3 Definitions 3.1 Terms defined elsewhere None. 3.2 Terms defined in this Recommendation This Recommendation defines the following terms: 3.2.1 abnormal DC voltage range: DC voltage range at interface P where ICT equipment may not operate within its specification, but is not damaged. 3.2.2 DC voltage range: DC voltage range at interface P. 3.2.3 ICT equipment: Information and communication equipment (e.g., switch, transmitter, router, server, and peripheral devices) used in telecommunication centres, data centres and customer premises. 3.2.4 interface P: Interface, physical point, at which power feeding system is connected to operate ICT equipment. Refer to Figure 1. 3.2.5 normal DC voltage range: DC voltage range at interface P where ICT equipment operates within its specification. 3.2.6 power feeding system: Power source to which ICT equipment is intended to be connected. 4 Abbreviations and acronyms This Recommendation uses the following abbreviations and acronyms: AC Alternating Current (also when used as a suffix to units of measurement) DC Direct Current (also when used as a suffix to units of measurement) EMC Electromagnetic Compatibility GHG Green House Gas ICT Information and Communication Technology PE Protective Earth Rg Resistance for the grounding system UPS Uninterruptible Power Supply U T Reference test voltage V o output Voltage of power feeding system VDC Volts DC 5 Conventions None. 6 DC power feeding interface specification This clause describes the DC power feeding interface to ICT equipment in data centres, telecommunication centres and customer premises. 2 Rec. ITU-T L.1200 (05/2012)

6.1 Definition of DC power feeding interface (+) Power feeding system ( ) PE ICT equipment Interface P L.1200(12)_F01 Figure 1 Definition of interface P The power feeding interface, shown as interface P in Figure 1, is a physical point at which all the requirements apply. This point is situated between the power feeding system and ICT equipment in accordance with [IEC 60445]. In this clause, all specifications are defined at the input of ICT equipment. Figure 2 shows a typical use of interface P. Power feeding system ICT equipment AC mains AC power Rectifier AC/DC converter DC power Battery system Interface P Definitions such as DC voltage range is defined at this interface point L.1200(12)_F02 Figure 2 Illustration of power feeding system and ICT equipment 6.2 Voltage range at interface P 6.2.1 Normal DC voltage range The maximum environmental benefit will only be achieved by transitioning towards a single voltage interface: the target solution. However, it is also recognized that there have already been some regional developments in DC for powering ICT equipment. To take advantage of the benefits resulting from a single voltage range interface (the target solution), a transitional period will be specified during which a transitional solution is allowed towards the single DC voltage range at the input of the ICT equipment. The target delay for full implementation of the target solution shall be as short as possible from the date of publication of this Recommendation. Target solution This solution has the following characteristics: The normal voltage range is the range of steady-state voltage over which ICT equipment shall maintain a specified normal service. The minimum voltage is 260 V. The maximum voltage is 400 V. Rec. ITU-T L.1200 (05/2012) 3

The voltage at the output of the power supply must take into account the voltage drop in the cable at a maximum steady current. Any new ICT equipment or electrical room installation compliant with this Recommendation shall use this target voltage range (260-400 V). Transitional solution The transitional voltage range over which ICT equipment shall maintain a specified normal service is 192 V-288 V. This can be used for the migration of DC systems towards the recommended target voltage range for a limited time in some regions. 6.2.2 Abnormal DC voltage range ICT equipment may be subjected to steady-state voltage out of the normal DC voltage range for the target solution. The limits of an abnormal DC voltage range for the target solution are defined as follows: 0 V < U < 260 V. 400 V < U < 410 V. After the restoration of the supply from the abnormal DC voltage range to the normal DC voltage range, the ICT equipment shall not incur any damage and will be able to automatically resume operation according to its specifications when the voltage comes back into the normal DC voltage range. 6.3 Reference test voltage (U T ) at interface P Reference test voltages (U T ) for the target solution at interface P for ICT equipment are defined as U T = 380 V or U T = 300 V depending on system requirements. NOTE Different U T can be defined because there can be different operating voltages inside the target voltage range. 6.4 Abnormal conditions Under abnormal conditions, voltage values outside the normal DC voltage range for the target solution may occur for a short time. The deviations from the steady-state voltage at interface P may be caused by: voltage variations; voltage dips; voltage interruptions; voltage surges/transients. The tests for voltage dips, short interruptions and voltage variations shall be conducted in accordance with [IEC 61000-4-29]. The tests for voltage surges shall be conducted in accordance with [IEC 61000-4-5]. Specific criteria for ICT equipment are defined in the tables below which display testing details. The detailed specifications of the generator are in Annex F of [ETSI EN 300-132-3-1]. The tests shall be performed on individual modules/subsystems. Compliance criteria are as follows: Criteria a) ICT equipment shall continue to operate as intended during and after the test. No degradation of performance or loss of function is allowed below a performance level specified by the manufacturer for when the ICT equipment is used as intended. 4 Rec. ITU-T L.1200 (05/2012)

Criteria b) Temporary loss of function or degradation of performance should cease after the disturbance ceases and the equipment under test should return to its normal performance level, without operator intervention. 6.4.1 Voltage variation The voltage variation at interface P shall be tested by referring to [ETSI EN 300-132-3-1]. The condition and compliance criteria for testing are in Table 1. Table 1 Test levels, duration and compliance criteria for voltage variation Voltage From U T to 260 V, back to U T From U T to 400 V, back to U T From U T to 410 V, back to U T From U T to 420 V, back to U T Duration Compliance criteria on ICT equipment 1 min Criteria a) Normal performance 1 min Criteria a) Normal performance 1 s Criteria b) Temporary loss of function or degradation of performance; automatic recovery to normal performance after the test. 10 ms Criteria b) Temporary loss of function or degradation of performance; automatic recovery to normal performance after the test. Comments Test of minimum operating voltage at interface P within the normal DC voltage range. Test of maximum operating voltage at interface P within the normal DC voltage range. Test of voltage increase variation entering the abnormal DC voltage range. Test of voltage increase variation outside the abnormal DC voltage range. 6.4.2 Voltage dips The voltage interruption at interface P shall be tested by referring to [ETSI EN 300-132-3-1]. The condition and compliance criteria for testing are in Table 2. Table 2 Test levels, duration and compliance criteria for voltage dips Voltage From U T to 260V, back to U T Duration Compliance criteria on ICT equipment 10 ms Criteria a) Normal performance Comments Test of minimum operating voltage at interface P within the normal DC voltage range. 6.4.3 Short interruptions The short interruption at interface P shall be tested by referring to [ETSI EN 300-132-3-1]. The condition and compliance criteria for testing are in Table 3. Rec. ITU-T L.1200 (05/2012) 5

Voltage U T to 0 V back to U T U T to 0 V back to U T Table 3 Test levels, duration and compliance criteria for short interruptions Supply network Low impedance (short circuit) High impedance (open circuit) Duration Compliance criteria on ICT equipment 10 ms Criteria a) Normal performance 1 s Criteria b) Temporary loss of function or degradation of performance, automatic recovery to normal performance after the test. Comments Test of hold-up time during fault clearing due to a short-circuit in the system. Test of automatic recovery after an extended (>1 s) interruption of the operating voltage at interface P. NOTE 1 With reference to clauses 6.1.1 and 6.1.2 of [IEC 61000-4-29] the definition of low impedance is a generator output impedance < 0.5 Ω and high impedance > 100 k Ω. NOTE 2 The purpose of the second test above ("High impedance") is to test the performance of the system during a power start-up of the system from 0 V (i.e., all system capacitors are fully discharged). This reflects the reset of a tripped circuit-breaker on interface P or DC interruptions in the network caused by transient voltage. This reset can also occur with the recovery of interface P voltage following the restoration of AC mains after an AC mains interruption longer than the battery backup time. 6.4.4 Voltage surges/transients The voltage surges at interface P shall be tested by referring to [IEC 61000-4-5] and [ETSI EN 300-132-3-1]. The condition and compliance criteria for testing are in Table 4. Voltage surges may occur at interface P when faults (e.g., short circuits) occur in the power distribution system. The voltage surges due to short circuits and protective device clearance are characterized by a voltage drop in the abnormal voltage range, followed by an overvoltage often in excess of the maximum abnormal voltage range and dependent upon the power distribution up to interface P and the ICT equipment connected to interface P. The purpose of this clause is thus to address the energy and subsequent so-called "fuse blowing surge" associated with a short circuit. Other voltage surges induced from other external sources, e.g., faults on the AC mains or lightning, belong to EMC generic requirements and are outside the scope of this Recommendation. Due to the lack of commercial test generators for testing voltage surges, according to this clause, references are, however, given for the EMC standard to reuse the so-called combination generator specified in [IEC 61000-4-5]. Table 4 Test levels, wave shape and compliance criteria for voltage surges/transients Test voltage Supply network Wave shape Compliance criteria on ICT equipment Comments 500 V Line to line 1.2/50 µs (8/20 µs) Criteria a) Normal performance Test of voltage increase variation outside the abnormal voltage range (e.g., due to fuse blow, switching). Test voltage polarity shall be the same as for interface P. 6 Rec. ITU-T L.1200 (05/2012)

Table 4 Test levels, wave shape and compliance criteria for voltage surges/transients Test voltage Supply network Wave shape Compliance criteria on ICT equipment Comments 500 V Line to ground 1.2/50 µs (8/20 µs) 2 kv Line to line 1.2/50 µs (8/20 µs) 2 kv Line to ground 1.2/50 µs (8/20 µs) Criteria a) Normal performance Criteria b) Temporary loss of function degradation of performance, automatic recovery to normal performance after the test. Criteria b) Temporary loss of function degradation of performance, automatic recovery to normal performance after the test. Test of voltage increase variation outside the abnormal voltage range (e.g., due to fuse blow, switching). Test voltage polarity shall be the same as for interface P. Test of automatic system recovery after a line-to-line short-circuit condition. Test voltage polarity shall be the same as for interface P. Test of automatic system recovery after a line-to-ground (line-to-pe) short-circuit condition. Test voltage polarity shall be the same as for interface P. NOTE 1 Lengthening of the interruption to service (equipment is not functioning as intended) due to the recovery of software should be declared in the test report (i.e., details about the service interruption). NOTE 2 To prevent system malfunctioning, additional arrangements concerning the power supply system may be necessary. For example: dual feeding system; high ohmic distribution system; independent power distribution. NOTE 3 Special precautions are normally taken in power distribution networks to fulfil compliance criteria a) for mission critical ICT equipment, i.e., to prevent functional disturbances due to the voltage surges treated in this clause. 6.5 Inrush current The inrush current pulse shall be limited in magnitude and in time duration to avoid protective devices clearance by excess current and energy passing through them. The inrush current of ICT equipment at interface P shall be tested by referring to [ETSI EN 300-132-3-1]. Rec. ITU-T L.1200 (05/2012) 7

Appendix I Information on grounding method (This appendix does not form an integral part of this Recommendation.) I.1 Basic configuration All cabinets/chassis in the 'up to 400 VDC' system should have a protective earth (PE). A high resistance R g connected between each power line and ground at the output section of the rectifier shall be neutral. By using R g, the ground-fault current should be controlled to be less than 20 ma. A protective circuit, such as a fuse/circuit-breaker, should be installed in the positive and negative power lines because both poles of the power line have a V o /2 voltage to the ground level. (An example of the basic configuration is shown in Figure I.1.) Because of the necessity to ensure human safety, and due to the low level ground fault current, the power system should have a leakage current detector and an alarm function. Rectifier DC power distribution DC power output (+) (+) ICT equipment V o R g R g V/2 o V/2 o Battery unit PE ( ) ( ) PE PE PE Interface P L.1200(12)_FI.1 Figure I.1 Example of the basic configuration of a grounding system for an 'up to 400 VDC' system I.2 Specification for PE at interface P The power lines and PE ports (PE ports are connected to the metallic enclosure of the equipment on Figures I.1 and I.2) at interface P of the PSU should be isolated. To ensure protection against any stray current, the input and output power ports of the PSU should be isolated; namely, the power converter should be isolated e.g., by a transformer (see Figure I.2). ICT equipment Up to 400 V DC power feeding system (+) Isolation Power supply unit ( ) PE Isolation Interface P L.1200(12)_FI.2 Figure I.2 Grounding system configuration for an 'up to 400 VDC' system 8 Rec. ITU-T L.1200 (05/2012)

The safety, earthing and bonding should use ITU-T work and other standards from IEC and ETSI. In particular the use of interface P should maintain compliance with [b-iec 60950-1]. If there is a need for monitoring including alarms, the interface protocol might be based on [b-etsi ES 202 336-1] and [b-etsi ES 202 336-2]. Rec. ITU-T L.1200 (05/2012) 9

Bibliography [b-etsi ES 202 336-1] EN 202 336-1 (in force), Environmental Engineering (EE); Monitoring and Control Interface for Infrastructure Equipment (Power, Cooling and Building Environment Systems used in Telecommunication Networks) Part 1: Generic Interface. [b-etsi EN 202 336-2] EN 202 336-2 (in force), Environmental Engineering (EE); Monitoring and control interface for infrastructure equipment (Power, Cooling and environment systems used in telecommunication networks) Part 2: DC power system control and monitoring information model. [b-iec 60950-1] IEC 60950-1 (2005), Information technology equipment Safety Part 1: General requirements. [b-dc Distribution 2] Babasaki, T. et al., (2010), Developing of higher voltage directcurrent power-feeding prototype system, Telecommunications Energy Conference, INTELEC 2009, pp. 1-5, IEEE. [b-grounding concept] Hirose, K. et al., (2011), Grounding concept considerations and recommendations for 400 VDC distribution system, Telecommunications Energy Conference (INTELEC), pp. 1-8, IEEE. [b-dc Architecture] Marquet, D. and Kervarrec, G. (2005), New Flexible Powering Architecture for Integrated Service Operators, Telecommunications Conference, INTELEC '05, pp. 575-580, IEEE. [b-dc Distribution 1] Pratt, A., Kumar, P. and Aldridge, T.V. (2007), Evaluation of 400 VDC distribution in telco and data centers to improve energy efficiency, Telecommunications Energy Conference, INTELEC 2007, pp. 32-39, IEEE. [b-dc grounding] Tanaka, T. et al., (2009), Basic study on grounding system for highvoltage direct current power supply system, Telecommunications Energy Conference, INTELEC 2009, pp. 1-4., IEEE. [b-dc Fuse] Tanaka, T., Babasaki, T. and Mino, M. (2008), Fuse blowing characteristics for HVDC power supply systems, Telecommunications Energy Conference, INTELEC 2008, pp. 1-6, IEEE. [b-dc Characteristics] Babasaki, T. et al., (2010), Basic Characteristics of New Developed Higher-Voltage Direct-Current Power-Feeding Prototype System, IEICE Transactions on Communications Vol. E93-B No. 9 pp. 2244 2249. 10 Rec. ITU-T L.1200 (05/2012)

SERIES OF ITU-T RECOMMENDATIONS Series A Series D Series E Series F Series G Series H Series I Series J Series K Series L Series M Series N Series O Series P Series Q Series R Series S Series T Series U Series V Series X Series Y Series Z Organization of the work of ITU-T General tariff principles Overall network operation, telephone service, service operation and human factors Non-telephone telecommunication services Transmission systems and media, digital systems and networks Audiovisual and multimedia systems Integrated services digital network Cable networks and transmission of television, sound programme and other multimedia signals Protection against interference Construction, installation and protection of cables and other elements of outside plant Telecommunication management, including TMN and network maintenance Maintenance: international sound programme and television transmission circuits Specifications of measuring equipment Terminals and subjective and objective assessment methods Switching and signalling Telegraph transmission Telegraph services terminal equipment Terminals for telematic services Telegraph switching Data communication over the telephone network Data networks, open system communications and security Global information infrastructure, Internet protocol aspects and next-generation networks Languages and general software aspects for telecommunication systems Printed in Switzerland Geneva, 2012