Dell SCv3000 and SCv3020 Storage System Getting Started Guide

Similar documents
Dell SC5020 and SC5020F Storage Systems Getting Started Guide

Dell SC7020 Storage Controller Getting Started Guide

Dell Storage Center. Getting Started Guide. SCv2000 and SCv2020 Storage System. Regulatory Model: E09J, E10J Regulatory Type: E09J001, E10J001

Dell SC460 Expansion Enclosure Getting Started Guide

Dell SCv3000 and SCv3020 Storage System Owner s Manual

SCv360 Expansion Enclosure

Dell SC7020 and SC7020F Storage Systems Owner s Manual

Dell MD1280 Storage Enclosure Getting Started Guide

Dell PowerEdge R720 and R720xd Getting Started Guide

Dell SCv300 and SCv320 Expansion Enclosure Owner's Manual

Dell PowerEdge T420 Getting Started Guide

Dell PowerEdge T620 Getting Started Guide

Dell EMC Storage MD1280 Enclosure Owner's Manual

Dell PowerVault MD3060e Storage Enclosure Owner's Manual

Dell PowerEdge T620 Getting Started Guide

Dell SC5020 and SC5020F Storage System Owner s Manual

SCv3000 and SCv3020 Storage System. Owner s Manual

DELL EMC SC SERIES EXPANSION ENCLOSURES

Dell PowerVault MD3400/3420/3800i/3820i/3800f/ 3820f Storage Arrays Getting Started Guide

StorNext M440 Site Planning Guide

Installing the IPS 4345 and IPS 4360

Dell Storage MD1400 and MD1420 Enclosures Getting Started Guide

Dell EMC PowerVault MD3460 Storage Arrays

IndigoVision Enterprise NVR-AS 4000 Linux Appliance. Quick Start Guide

Dell PowerVault MD3460/3860i/3860f Storage Arrays Getting Started Guide

IndigoVision Enterprise NVR-AS 4000 G3 Windows Appliance. Quick Start Guide

Dell Storage MD1400 Enclosures Hardware Owner's Manual

System Storage DS3950 Quick Start Guide

Dell Storage Center. Owner's Manual. SC180 Expansion Enclosure. Regulatory Model: E11J Regulatory Type: E11J001

ftserver 3300 Service Bulletin

Dell Networking S4100-ON Series. Set-Up Guide

E-Series Site Preparation Guide

Dell PowerVault MD3800i and MD3820i Storage Arrays Owner's Manual

Dell Storage Center. Owner's Manual. SC9000 Storage System. Regulatory Model: E09J, E10J Regulatory Type: E09J001, E10J001

SGI InfiniteStorage 120

Dell PowerVault MD3400/3420/3800i/3820i/ 3800f/3820f Storage Arrays Getting Started Guide

Dell EMC PowerEdge R6415

Dell PowerEdge FC640. Technical Specifications. Regulatory Model: E02B Series Regulatory Type: E02B005

Dell EMC ME4 Series JBOD 5U84 Enclosure

NOTE: Use the System Setup program to view microprocessor information. For more information, see "Using the System Setup Program."

Dell PowerEdge M905, M805, M605, and M600. Getting Started With Your System

Power Enclosure Components

S5048F-ON. Set-up Guide

Dell EMC PowerEdge T440

N3240 Installation and Setup Instructions

Artico NAS Storage Appliance Site Planning Guide

Dell EMC PowerEdge R7415

JanusRAID SA-6692J Hardware User Manual

Dell EMC PowerEdge XR2

Dell EMC PowerEdge MX7000 Enclosure

Dell EMC PowerEdge R540

2U STORAGE ENCLOSURE QUICK INSTALL GUIDE FS4100, FS4500, SC4100, AND FC4100

Installation Job Aid for VSP 4450GTX-HT- PWR+

N3220 Installation and Setup Instructions

Junos WebApp Secure 5.0 Hardware Guide

Installing the Cisco MDS 9020 Fabric Switch

Installation Note for the Cisco ME 3800X and ME 3600X Switch Power Supply and Fan Modules

DNS-2608 Enterprise JBOD Enclosure User Manual

Customer Replacement Procedure

Dell EMC PowerEdge R7425

TECHNICAL SPECIFICATION. Brocade 6510 Switch Technical Specifications

Table of Contents Quick Install Guide page Introduction Safety Rack System Precautions ESD Precautions...

Dell PowerEdge FD332. Owner's Manual. Regulatory Model: E02B Regulatory Type: E02B003

1 Getting Started Installing & Configuring

Dell Networking S4810 Open Networking (ON) Getting Started Guide

VEP4600. Setup Guide

DELL EMC DATA DOMAIN DEDUPLICATION STORAGE SYSTEMS

Inspiron Setup and Specifications

G5 PDU Installation Guide

OmniCube CN-Series. Hardware Installation and Maintenance Guide CN-2000 CN-2200 CN-3000 CN-5000

Omnitron Systems Technology, Inc. 1. iconverter. 19-Module Managed Power Chassis User s Manual

Dell Latitude in-1

Installation Job Aid for VSP 4850GTS

Inspiron Setup and Specifications

Dell OptiPlex All-in-One. Stand Installation Guide

Dell EMC PowerEdge R540

Installation Job Aid for Avaya Virtual Services Platform 8400

Dell Precision Workstation T7500/T7500n Setup and Features Information

Dell Latitude E5410/E5510

TELCO. Tomi Männikkö/HW Architect, Datacenter R&D/ Nokia

Dell EMC PowerEdge R740

XPS 27 Setup and Specifications

DELL EMC DATA DOMAIN DEDUPLICATION STORAGE SYSTEMS

VIRTUAL EDGE PLATFORM 4600 Next Generation Access

G3-APEX-ENT-32T. Apex technical specifications. Parts list

Dell Inspiron 300/400 Comprehensive Specifications

Xcellis Workflow Extender (R520) Site Planning Guide

Replacing an Advanced Power and Cooling (APC) Unit

Dell EMC Data Domain DD6300, DD6800, and DD9300 Systems

Field-Replaceable Units

Inspiron Setup and Specifications

Inspiron Setup and Specifications

4700 Series RAID-Enabled Industrial PCs DS _RAID(C)

Dell EMC PowerEdge R740xd

Customer Upgrade Procedure

EMC SYMMETRIX VMAX 10K

DELL EMC DATA DOMAIN DEDUPLICATION STORAGE SYSTEMS

Dell PowerEdge R640. Technical Specifications. Regulatory Model: E39S Series Regulatory Type: E39S001

TECHNICAL SPECIFICATIONS + TECHNICAL OFFER

Next Generation Firewall

Transcription:

Dell SCv3000 and SCv3020 Storage System Getting Started Guide Regulatory Model: E03T Regulatory Type: E03T001

Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make better use of your product. CAUTION: A CAUTION indicates either potential damage to hardware or loss of data and tells you how to avoid the problem. WARNING: A WARNING indicates a potential for property damage, personal injury, or death. Copyright 2017 Dell Inc. or its subsidiaries. All rights reserved. Dell, EMC, and other trademarks are trademarks of Dell Inc. or its subsidiaries. Other trademarks may be trademarks of their respective owners. 2017-8 Rev. A00

Setting Up the Storage System Consider the following best practices when setting up an SCv3000/SCv3020 storage system. Dell recommends that you use a dedicated SAN network for data transmission when using a Fibre Channel or iscsi storage system. Always configure redundant data paths to provide alternate paths to and from the host server should one of the data paths become disabled. Before connecting any cables between the storage system and host server or expansion enclosure, physically label each port and connector. Always follow proper power-up and power-down procedures when cycling power across the network. Verify that critical network components are on separate power circuits. NOTE: This product is intended for restricted access locations, such as a dedicated equipment room or equipment closet. WARNING: If installed in a closed or multi-unit rack assembly, the operating ambient temperature of the rack environment may be greater than room ambient temperature. Therefore, consideration should be given to installing the equipment in an environment compatible with the maximum ambient temperature (Tma) specified by the manufacturer. Safety Warnings Two person lift required A fully configured SCv3000/SCv3020 storage system weighs approximately 43 kg (95 lb). Use appropriate lifting methods when installing the storage system. Laser Radiation for Fibre Channel Storage Systems CAUTION: Class I laser radiation when open, avoid exposure to beam. WARNING: Laser radiation, avoid direct exposure to beam. The unit is certified in the U.S. to conform to the requirements of DHHS 21 CFR, chapter 1 Subchapter J for Class I (1) laser products, and elsewhere is certified as a Class I laser product conforming to the requirements of IEC 60825-1:2007. Class I laser products are not considered to be hazardous. The laser system and unit are designed so there is never any human access to laser radiation above a Class I level during normal operation, user maintenance or prescribed service condition. Locating Your Service Tag Your storage system is identified by a unique service tag and Express Service Code. The service tag and Express Service Code are found on the front of the system by pulling out the information tag. Alternatively, the information might be on a sticker on the back of the storage system chassis. This information is used by Dell to route support calls to the appropriate personnel. NOTE: The Quick Resource Locator (QRL) code on the information tag is unique to your system. Scan the QRL to get immediate access to your system information using your smart phone or tablet. 3

Other Information You May Need To install the storage system, you may need the following additional information. NOTE: See the safety and regulatory information that shipped with your Storage Center components. Warranty information is included as a separate document. The Dell SCv3000/SCv3020 Storage System Deployment Guide provides information about cabling storage system hardware components and configuring a new storage system using the Dell Storage Manager Client. The Dell Storage Manager Administrator s Guide describes how to use Dell Storage Manager to manage Storage Center systems. Installation and Configuration Before you begin installation, make sure that the site where you plan to install the storage system has standard power from an independent source or a rack power distribution unit with a UPS. In addition, verify that there is a 3U space in the lower 20U of the rack to install the storage system. If you plan to install the storage system above the lower 20U of a rack, a customer-provided mechanical lift must be used to avoid injury. Unpacking Storage Center Equipment Unpack the storage system and identify the items in your shipment. Figure 1. SCv3000/SCv3020 Storage System Components 1. Documentation 2. Storage system 3. Rack rails 4. USB cables (2) 5. Power cables (2) 6. Front bezel Install the Storage System in a Rack Install the storage system and other Storage Center system components in a rack. About this task Mount the storage system and expansion enclosures in a manner that allows for expansion in the rack and prevents the rack from becoming top heavy. 4

The SCv3000/SCv3020 storage system ships with a ReadyRails II kit. The rails come in two different styles: tool-less and tooled. Follow the detailed installation instructions located in the rail kit box for your particular style of rails. Steps NOTE: Dell recommends using two people to install the rails, one at the front of the rack and one at the back. 1. Position the left and right rail end pieces labeled FRONT facing inward. 2. Align each end piece with the top and bottom holes of the appropriate U space. Figure 2. Attach the Rails to the Rack 3. Engage the back end of the rail until it fully seats and the latch locks into place. 4. Engage the front end of the rail until it fully seats and the latch locks into place. 5. Align the system with the rails and slide the storage system into the rack. Figure 3. Slide the Storage System Onto the Rails 6. Lift the latches on each side of the front panel and tighten the screws to the rack. 5

Figure 4. Tighten the Screws If the Storage Center system includes expansion enclosures, mount the expansion enclosures in the rack. See the instructions included with the expansion enclosure for detailed steps. Install the Front Bezel Install the bezel on the front of the storage system. 1. Hook the right end of the bezel onto the storage system. Figure 5. Front Bezel 2. Insert the left end of the bezel into the securing slot until the release latch snaps into place. 3. Secure the bezel with the keylock. 6

Connect the Power Cables Connect power cables to the storage system. 1. Make sure that the power switches are in the OFF position before connecting the power cables. 2. Connect the power cables securely to both power supply/cooling fan modules in the storage system chassis. Figure 6. Connect the Power Cables 3. Use the straps to secure the power cables to the storage system chassis. Figure 7. Secure the Power Cables 4. Plug the other end of the power cables into a grounded electrical outlet or a separate power source such as an uninterrupted power supply (UPS) or a power distribution unit (PDU). NOM Information (Mexico Only) The following information is provided on the device described in this document in compliance with the requirements of the official Mexican standards (NOM): Importer Model number Dell Inc. de México, S.A. de C.V Paseo de la Reforma 2620-11 Piso Col. Lomas Atlas 11950 México, D.F. E03T Supply voltage 100 240 VAC (1378 W) 7

200 240 VAC (1485 W) Frequency 50/60 Hz Current consumption 16A-8.25A (1378 W) 8.8 A (1485 W) Technical Specifications The technical specifications of the SCv3000/SCv3020 storage systems are displayed in the following tables. Drives SAS hard drives SCv3000 Up to 16 3.5-in. hot-swappable hard drives (12 Gb SAS) SCv3020 Up to 30 2.5-in. SAS hot-swappable hard drives (12 Gb SAS) Storage Controllers Storage controllers Up to two hot-swappable storage controllers with one I/O card slot and one optional mezzanine card per storage controller. Each storage controller has an internal battery backup unit. Write cache is mirrored between the two storage controllers. If a power failure occurs, the battery backup unit provides power to the storage controller so that the write cache can be saved to an SSD within the storage controller. Storage Connectivity Configurations SCv3000 Supports a total of 150 drives and up to 120 drives on a single SAS chain. SCv3020 Supports a total of 150 drives and up to 134 drives on a single SAS chain. Redundant Array of Independent Disks (RAID) Controller Management Two hot-swappable storage controllers RAID management using the Dell Storage Manager Client Back-Panel Ports Connectors (per Storage Controller) Fibre Channel, iscsi, or SAS front-end connectors Ethernet connectors SAS back-end connectors Connection to a Fiber Channel fabric, iscsi network, or a direct connection to servers with SAS HBAs MGMT 1 Gbps embedded Ethernet port used for Storage Center management 12 Gb SAS ports for connections to expansion enclosures NOTE: SAS connectors are SFF-8644 compliant. Serial connector (micro USB) Used for initial configuration and support-only functions LED Indicators Front panel One dual-color LED indicator for system status One single-color LED indicator for power status 8

LED Indicators Identification button with a single-color LED Hard drive carrier One single-color activity LED One dual-color LED status indicator per drive Storage controller Two single-color LEDs per Ethernet port indicating activity and link speed One dual-color LED per SAS connector indicating port activity and status One single-color LED indicating status One single-color LED indicating system faults One single-color LED for system identification Power supply/cooling fan One dual-color LED handle indicating power supply and cooling fan status Power Supply Units (PSU) AC power supply (per power supply) PSU Type 1 PSU Type 2 (Japan Only) PSU Type 3 Maximum output power 1485 W 1485 W 1378 W Maximum input power 1688 W 1707 W 1584 W Maximum input current 8.8 A 17.5 A 16 A Maximum inrush current 55 A for 10 ms or less 55 A for 10 ms or less 55 A for 10 ms or less Nominal input voltage operating range 200 240 VAC 100 240 VAC 100 240 VAC Nominal input frequency 50/60 Hz 50/60 Hz 50/60 Hz Thermal output/heat dissipation 693 BTU per hour 757 BTU per hour 703 BTU per hour Available Hard Drive Power (Per Slot) Supported hard drive power consumption (continuous) Up to 1.2 A at +5 V Up to 0.5 A at +12 V Physical Height Width Depth 13.34 cm (5.25 in.) 44.50 cm (17.5 in.) SCv3000 81.91 cm (32.25 in.) SCv3020 78.27 cm (31 in.) Approximate weight (maximum configuration) SCv3000 45 kg SCv3020 43 kg Approximate weight without drives 32.5 kg (72 lb) 9

Environmental For additional information about environmental measurements for specific storage system configurations, see dell.com/ environmental_datasheets. Temperature Operating Storage 10 C (50 F) to 35 C (95 F) with a maximum temperature gradation of 20 C/ hour (36 F/hour) Operating above 35 C could result in data loss 40 to 65 C ( 40 to 149 F) at a maximum altitude of 12,000 m (39,370 ft) Relative humidity Operating Storage 10% to 80% (noncondensing) with 29 C (84.2 F) maximum dew point 5% to 95% (noncondensing) with 33 C (91 F) maximum dew point Maximum vibration Operating Storage 0.21 G at 5 500 Hz for 15 min 1.04 G at 2 200 Hz for 15 min Maximum shock Operating 31 G +/- 5% with pulse duration of 2.6 ms +/- 10% (equivalent to 20 in./sec [51 cm/sec]) Storage 71 G +/- 5% with pulse duration of 2 ms +/- 10% (equivalent to 35 in./sec [89 cm/sec]) Altitude Operating Storage 3,048 m (10,000 ft) 35 C (95 F) Maximum Rating Maximum temperature is reduced by 1 C/300 m (1 F/547 ft) above 950 m (3,117 ft) 12,000 m (39,370 ft) Airborne Contaminant Level Class G1 or lower as defined by ISA-S71.04-1985 10