A/E REVIEW CHECKLIST TELECOMMUNICATIONS SYSTEMS

Similar documents
DUKE UNIVERSITY CONSTRUCTION STANDARDS

f) Telecommunications Equipment Rooms

2 Telecommunications Data Center Facility Requirements

Office of the Chief Information Officer Technical Note: IT-960-TN14 Effective: 05/25/2006 Last Revised: 02/17/2012 Issuing Office: OCIO

Communications. UNM IT/Telecommunications Guide Specification Communications

Tier IV Standards as Specified in the TIA 942 Document

V I S I N. Technology Planning IFMA V I S I O N. March1, 2007

ANSI/TIA/EIA-568-B Cabling Standard NOTE

UGA DESIGN & CONSTRUCTION SUPPLEMENTAL GENERAL REQUIREMENTS & STANDARDS TABLE OF CONTENTS

17. Microwave Collocation 17.1 General

UGA DESIGN & CONSTRUCTION SUPPLEMENTAL GENERAL REQUIREMENTS & STANDARDS TABLE OF CONTENTS

FACILITY COMPONENTS - MIDDLE SCHOOL

Communications Site Installation R56 Installer and Communications Site Inspector/Auditor version COMPETENCY REQUIREMENTS

DS-1H05 Ethernet-over-Coax Extender. User Manual

INTERIM COMMUNICATIONS INFRASTRUCTURE PLANNING GUIDELINES

FLORIDA STATE UNIVERSITY MASTER PLAN 10 Utilities

Chapter 1 Introduction to Outside Plant

AT&T Dedicated Internet (ADI formerly known as MIS) and Private Network Transport (PNT)

AT&T Virtual Private Network Service (VPN) and AT&T VPN Express

FLP-PS DC Power Supply Model. Portable Sound System Mixer Amp/ Pre Amp/ Power Amp

FCC Regulatory Information

WS must be used in a temperature controlled place. It is compliant to ETS Class T

XBR V4 INSTALLATION AND USER GUIDE

SPI PowerNet requirements for the non-contestable Interface Works at Deer Park Terminal Station

DIVISION 27 COMMUNICATIONS

Open Access. Definitions

AT&T Dedicated Internet (ADI formerly known as MIS) and Private Network Transport (PNT)

Peter Sharp RCDD IBI Group

INTERNATIONAL STANDARD

Huawei Railway Communication Service Solution Guide

Clark Atlanta University. Facilities Modification Request Form

Design Guidelines for Facilities Construction:

DDW36A Advanced Wireless Gateway - Safety and Installation Product Insert. Federal Communications Commission (FCC) Interference Statement

XBR V3 INSTALLATION AND USER GUIDE Rev 03. xbr V3 Installation and User Guide Page 1 of 14. (preliminary)

Twin Core Data Center Munich

1 QUESTIONS/Answers PAGE 1 OF 10. Addendum 2 Request for Proposal FY Voice Data and Infrastructure Cable

AT&T Virtual Private Network Service (VPN) and AT&T VPN Express

Please read this safety information carefully and keep this user manual for later reference.

INT 492 : Selected Topic in IT II (Data Center System Design) 3(3-0-6)

A Review of the National Electrical Code Articles that Affect Data Center Design By Leo Marsh, PE, RCDD JACOBS (CH2M)

The Riser as a Contract Document. Peter Sharp, RCDD

HP Performance-Optimized Datacenter, 12 m (40 ft) Site Requirements Information

Wireless Telecommunication Facility

UniCom Ltd. is global end-to-end services provider to telecom infrastructure industry.

PREVENTING DOWNTIME OF E911 CENTERS

Avanti HP Series Centrifuges Preinstallation

SMART HOME INFRASTRUCTURE RECOMMENDED GUIDELINES. A guide to Smart Home infrastructure requirements for the modern home

Cabling a Data Center to TIA-942 Standard

Run a Smart Workplace Introducing the Digital Building. Digital Building Solutions

Installation Notes TII Model 341 Protector

AT&T Switched Ethernet Service SM

DESIGN GUIDELINES. Building Circulation

INTERNATIONAL STANDARD

OPERATING INSTRUCTIONS PA AMPLIFIER P-1812

888385_01 Install.book Page 1 Wednesday, November 11, :45 PM. SMDR6 Installation Guide

DIVISION 0 - BIDDING REQUIREMENTS, CONTRACTOR FORMS AND CONDITIONS OF THE CONTRACT

Course Description. Audience. Prerequisites. : Course CTDC : Certified TIA-942 Design Consultant. Course Outline :: CTDC ::

Cable TV, Broadband, Telephone, and Security

RFP Questions Guideline For Data Center Buyers

SPOS (Station Point of Sale) 200. SFTP (Station Fare Transaction Processor) 35. CQD (Card Query Device) 35. HCR (Handheld Card Reader) Cradles 120

Data Center Design and the ANSI/TIA-942 Standard

Commissioning In Healthcare

Exede WiFi Modem USER GUIDE

NZQA registered unit standard version 2 Page 1 of 7. Demonstrate basic knowledge of electronic security data protocols and cabling

ANSI/TIA/EIA-568-B Cabling Standard

MICHIGAN DEPARTMENT OF TRANSPORTATION

Important Information KX-NTV150. Communication IP Camera. IP Video Doorphone. Model No. Model No. KX-NTV160

Data Cabling / Low Voltage Technology Specifications

Infrastructure Checklist

Security Integrator. Solutions. Your One Source for Physical Security, Network & Electrical. Solutions

Computer Network Design Guide Existing Systems 1 / 6

SECTION 5 -- EQUIPMENT LAYOUT & EQUIPMENT ENVIRONMENTS

Newark, Delaware Architectural Engineering Senior Thesis Portfolio

Current Control Houses

MEIengineering, inc. mechanical electrical industrial consultants South Main Street, Harrisonburg, VA (540)

Obtaining Documentation and Submitting a Service Request, page xvii Safety Warnings, page xvii Safety Guidelines, page xx

Technology Incubation Center. High Tech Cleanroom Laboratory & Production Facility.

V A Physical Security Assessments LESSONS LEARNED

OFFICE OF EDUCATIONAL FACILITIES SECTION 453 APPLICATION MATRIX

Security Integrator. Solutions. Your One Source for Physical Security, Network & Electrical. Solutions

HP Performance Optimized Datacenter (POD) 240a Site Requirements Guide

fulfils all requirements for high protection of the criteria catalogue The appendix is part of the certificate and consists of 6 pages.

Atras Network Communications

PRE116/126. User Manual.

Target Interface / Construction Compliance Inspection Checklist

MONTE VILLA FARMS MONTE VILLA PARKWAY BOTHELL, WASHINGTON

Installation Guide. Home Network System Smart Plug KX-HNA101FX. Model No. Thank you for purchasing a Panasonic product.

Tarleton State University. Specifications

fulfils all requirements for high protection of the criteria catalogue The appendix is part of the certificate and consists of 5 pages.

User Guide. DOCSIS 3.0 High Speed Cable Modem TC7650 REV

JT Rue Des Pres DATA CENTRE

Zip12. Charging Desktop Cabinet. User's Guide. Components. Tools Needed ENGLISH. Requires 2 people to remove from box. 6mm. M6 x 35mm Security Screw

Open Applications Interface (OAI) Installation and Setup

The following symbols are used to show dangerous operation or handling. Make sure you understand them before reading the guide.

Master Format Division 27 - Communications

CHAPTER WIRELESS TELECOMMUNICATION FACILITIES

NZQA unit standard version 2 Page 1 of 5

DSL-100FNT1 v2. Quick Installation Guide. Version 1.0 Date Mitrastar Network Technology Incorporation

ZXHN H268A Home Gateway User Manual

Integrated Security & Communications, Inc Products & Services

Transcription:

A/E REVIEW CHECKLIST TELECOMMUNICATIONS SYSTEMS May 1, 2016 Reviewers should - Be aware that these checklists are not allinclusive but only provide important review items. Reviewers should - Use Checklists when reviewing any type of VA construction project for the following disciplines: Architectural, Boiler Safety Devices Operation Checklist, Electrical, Heating, Ventilating, and Air Conditioning (HVAC), Incineration/Solid Waste, Information and Technology, Physical Security, Plumbing, Fire Protection, and Sanitary, Site and Landscape, Steam Generation and Distribution, Structural, and Telecommunications and Special Telecommunications Systems. Reviewers should - Insure that A/E Submission Instructions (PG-18-15) for Schematic, Design Development, and Construction Documents are followed for various types of VA construction projects. Reviewers should - Insure that every VA construction project is in compliance with all life safety issues. 1

GENERAL INFORMATION FOR REVIEWERS The reviewer should be thoroughly familiar with the following VA standards before conducting a design review. These are available on the CFM Internet Web site: http://www.cfm.va.gov/til/ 1. DESIGN MANUALS (PG-18-10) 2. MASTER CONSTRUCTION SPECIFICATIONS (PG-18-1) 3. STANDARD DETAILS (PG-18-4) 4. DESIGN AND CONSTRUCTION PROCEDURES (PG-18-3) 5. DESIGN GUIDES (PG-18-12) 6. SEISMIC DESIGN REQUIREMENTS (H-18-8) 7. DESIGN ALERTS 8. A/E QUALITY ALERTS 9. A/E SUBMISSION INSTRUCTIONS, PROGRAM GUIDE PG-18-15 10. TECHNICAL SUMMARIES 11. NATIONAL CAD STANDARD and VA NATIONAL CAD STANDARD APPLICATION GUIDE 2

SCHEMATICS 1 General Provisions For New Buildings - In addition to items given below check all requirements for buildings, telecommunications rooms, main computer room, etc. per Design and Construction Procedures Topic 8 and the Telecommunications and Special Telecommunications Systems Design Manual. a. For Mission Critical facilities, verify that there are two primary Service Provider duct banks, as electrically and physically separated as possible per Physical Security Design Manual. b. Telecommunications Rooms stack vertically. c. Quantity of Telecommunications Rooms shown on each floor: Maximum distance of the farthest telecommunications outlet to the nearest Telecommunications Room shall not exceed 80M (262 ft.) d. All Telecommunications Rooms shall be free of columns inside. e. Telecommunications Rooms shall be located above the Base Flood Elevation. Telecommunications Room rooms shall not be located beneath toilets, showers, laboratories, kitchens, sinks, open courtyards, planters, roof drain leaders, cooling towers, or other areas where water service is provided. f. Foreign piping such as water pipes, steam pipes, medical gas pipes, sanitary waste pipes, roof drains, A/C ducts, and other unrelated piping systems containing liquids or gasses shall not be installed in and shall not pass through these rooms including inside adjacent walls. g. Telecommunications rooms shall not be located adjacent to electrical rooms, elevator machine rooms, exterior walls, loading docks, mail rooms, nor in proximity to sources of electromagnetic and RF interference, fire and smoke hazards, wet or high humidity locations, and patient care areas. 3

SCHEMATICS 2 Copies of all correspondence and minutes of meetings with service provider s representatives regarding negotiations for new services or changes to the existing services are forwarded to COR as required in the VA Telecommunications and Special Telecommunications Systems Design Manual. 3 Predesign site survey of existing communications service is included. 4 Inventory of existing equipment to be reused is included. 5 Coordinate drawings with other technical disciplines including structural. 6 Compliance with VA National CAD Standard Application Guide and applicable National CAD Standard modules. 4

DESIGN DEVELOPMENT 1 All telecommunications rooms, main computer room and rooms that contain IT and FMS equipment shall not be located directly below showers, laboratories, kitchens, dishwashing areas or other areas where water service is provided. Pipe containing liquids or gases shall not pass through these rooms. See Physical Security Design Manual. 2 Compliance To Design and Construction Procedures a. Telecommunications and Special Telecommunications Systems TIP cabling distribution follow Telecommunications and Special Telecommunications Systems Design Manual requirements. b. Projects requiring new, replacement, or expansion of existing telecommunications service are coordinated with the local service provider(s) and respective Facility Service Chief(s) requirements. c. Telecommunications outlet heights are as required for equipment in different areas and Americans with Disabilities Act Standards for Accessible Design (see Telecommunications and Special Telecommunications Systems Design Manual) d. Electrical Grounding is coordinated with TMGB (see Telecommunications and Special Telecommunications Systems Design Manual). e. Raceway systems are as required in Telecommunications and Special Telecommunications Systems Design Manual. (1) All Public Address System cabling shall be installed in conduit. (2) Underground conduits shall be encased in concrete. (3) All inside TIP backbone cabling between the MCR and the TR(s) shall be installed in conduit 3 Each Wireless System is designed per Telecommunications and Special Telecommunications Systems Design Manual; including FCC restrictions of use. 5

DESIGN DEVELOPMENT a. Correspondence that design professional contacted VACO s AHJ for FMS Special Communications, Low Voltage and other Communication Systems; contact, Spectrum Management and COMSEC Service (SMCS 005OP2H3) for each wireless item and RF equipment/system for Spectrum and Frequency Coordination. b. Confirmed frequencies of Emergency Radio Communications System(s) used while inside the facility for each respective Emergency Responder and each approved RF for Facility use. c. Obtained prior approval from SMCS for any Service Provider (i.e. AT&T, Verizon, Sprint, etc.) cellular telephone DAS, Wi-Fi and RTLS functions to be provided in the facility. d. Intra-building Wireless System, Wireless Local Area Network (WLAN) includes SMCS 005OP2H3 approved MOU AND Risk Assessment Forms fully accomplished and signed by all parties. e. Heat maps are provided for the Facility indicating the channel coverage, signal level, data rate and noise floor for 802.11 (*) wireless networks. 4 Communications Circulating Grounding System (CCGS) shall be shown complete on a one-line diagram with all components and descriptions from the Intersystem Bonding Termination (IBT) at the service equipment to the TGBs, as applicable for this project. 5 Lightning Protection Grounding System (LPGS) shall be shown complete on a one-line diagram with all components and descriptions from Facility Antenna Farm mechanical and coaxial connection points to the external route to earth ground. 6 Coordinate drawings with other technical disciplines 7 Compliance with VA National CAD Standard Application Guide and applicable National CAD Standard modules. 6

CONSTRUCTION DOCUMENTS 1 Documents contain RCDD stamp. 2 Requirements for primary and secondary surge protection are included (see Telecommunications and Special Telecommunications Systems Design Manual). 3 Telecommunications rooms are sufficiently sized for cabinet, rack and equipment sizes using largest and/or heaviest dimensions and weights so that working clearance requirements, space for future installations, and structural requirements are satisfied. (see Telecommunications and Special Telecommunications Systems Design Manual). 4 Pathways including cable tray and conduits are sized for quantity of cables anticipated. (see Telecommunications and Special Telecommunications Systems Design Manual). 5 Coordinate drawings with other technical disciplines (see Telecommunications and Special Telecommunications Systems Design Manual): a. Equipment cooling and ventilation. b. Equipment power locations. c. Electrical loads. d. UPS sizing and loads are according to the Physical Security Design Manual. 6 Physical Security Systems are coordinated with door hardware, and Fire Detection and Notification Systems (see Physical Security Design Manual, NFPA 101 and VA Guide 0730). 7 Includes functional diagrams (Riser Diagrams) of Essential Telecommunications Systems, Controls and Operation such as Data, Voice (Telephone contact TVE 202-462-5311), Nurse Call, Emergency Call, Duress Alarm, PA, MATV, CCTV, IC, DAS, Intrusion Detection, Access Control (PACS), and Other Signal Systems. 8 Project documents procure and install Wireless LAN Controllers, and wireless access points. Drawings include two data cables terminated at Wireless Access Point locations approved by VA spectrum analysis and SMCS. 7

CONSTRUCTION DOCUMENTS 9 Includes large-scale (minimum 1/4"=1') partial plans for areas such as Main Computer Room, Telephone Equipment/Operator Room, Telecommunications Rooms, Network Operations Room, DEMARC, Antenna Head End Room, Police Control/Operation Rooms, Emergency Communications Control/Operations Rooms. Contact, Spectrum Management and COMSEC Service (SMCS 005OP2H3) for complete list. 10 Specifications are VA specifications from TIL. 11 All system Specifications include and refer to VA Section 27 05 11. 12 Compliance with VA National CAD Standard Application Guide and applicable National CAD Standard modules. 8