FP735Si Electronic 3-Channel Full Programmer for Heating and Hot Water with Service Interval Timer. Installation Guide MAKING MODERN LIVING POSSIBLE

Similar documents
TP5000 Si Range Electronic 5/2 day programmable room thermostat Mains, Battery and RF versions Installation and User Instructions

Model: EP210. Dual channel programmable controller. Installation Manual

Select 107 XLS User Instructions

BUP2 5/2 12/4/07 12:49 AM Page 1. Introduction

7 Day Digital Programmer 2 Channel Surface Mount

7 Day Digital Programmer 1 Channel Surface Mount

D GB F NL I E P. Overview per day of the programmed switching. Channel statuses are displayed ON / OFF

16 Amp 1 Channel Multi Purpose Programmer User Instructions

Table of Contents. Model: -hw. -hw. Series. Available in : Sapphire Black and Glacier White. Product Image. 16 Table of Contents

RWB29 Programmer. Daily Programming

WavePRO Wireless Programmable T2500 Thermostat & R2500 Receiver OPERATING MANUAL. Model K

Instruction Manual Digital socket box timer

Digital Room Thermostat for Underfloor Heating Applications

ERT50T Triac Noiseless Digital Room Thermostat for Underfloor Heating Applications

BUT2 7day 11/4/07 11:07 PM Page 1. Introduction

Model: Available in : Sapphire Black and Glacier White

Model: Available in : Sapphire Black and Glacier White

Digital Room Thermostat

ScottishPower Connect. User Guide

RVL470. Heating controller. G2522en. Installation Instructions. 1 Installation. 2 Commissioning Wall mounting DIN rail mounting

CentaurPlus C17 User Operating Instructions

Overview - Danfoss Link and Connect software versions

RAMSES D GB F NL. Installation and operating instructions Room thermostat. RAMSES 832 top2

Model: Touchpad (TFT) Model: TFT

Weekday / weekend room temperature controller

/2006 GB (EN) for the user. Users manual. ModuLink 250 RF - Twin channel modulating programmable room thermostat.

Temperature control unit

ST-292 User s manual. User manual ST-292 v1-3

Operating Instructions. Radio timer thermostat display. Table of contents

Model: TM-1 / TM1-N. 1 Time Clock Series

7-day room temperature controller

ZONETOUCH DAMPER CONTROL SYSTEM Operation Manual

Operating instructions for RAMSES 811 top2_812 top2 and RAMSES 831 top2_832 top2

Weekday / weekend room temperature controller

2 Zone Time Clock. User Guide UFHTIME2B

Model FP700 Owner s Instructions

S-Series Digital Thermostat

Simplified Operating Instructions T105-C / T108-C / T106-C / T17B-C DISPLAYS DAY OR DAY BLOCK PROG 00:0000 PROG PROG ALWAYS OFF

Iso DIN. User Manual. 1 channel Earth Fault Monitoring

7-day room temperature controller

Supplementary operating instructions for your air curtain system Controller TMC 500

SSR 303 One Channel 3 Amp Switch (Rx Only) - Z-Wave. User and Installation Instructions

Operation 6035 ENGLISH PROG MENU

TR TR 608 top TR 609 top D GB F I E NL. Installation and operating instructions Digital time switch. TR 609 top2

BACVIEW MANUAL Software Version 3.06 INSTALLATION AND OPERATION MANUAL

ECL Comfort V a.c. and 24 V a.c.

AMBIFLEX MF626 - USER GUIDE

MAKING MODERN LIVING POSSIBLE. Installation Guide. Twin Kit 086L

S-Series Digital Thermostat

Programmable Room Thermostat. User Guide UFHPROGB & UFHPROGRFB

Wireless 7 Day Programmable Room Thermostat

Basic User and Installation Manual

ST9100A User Guide. Features

7 Day Programmable Room Thermostat

MCX08M2 Programmable controller

STC7D. Digital Time Clock for TRC500 & TRC800. Installation, Operation, and Maintenance Manual

24V, Motorized Actuators

FCU-4 FAN COIL CONTROLLER

ZCM-12, ZCM-12P/U TIME PROGRAMMER WEEK S, DOUBLE CHANNEL

BLDA-1 & 2 Water Leak Detection Manual. CMR Electrical Ltd Bolton House Five Chimneys Lane Hadlow Down East Sussex TN22 4DX Tel:

Smart Series. Wall Heater Operations Manual. Save This Manual

BlueWave ~ Intelligent Energy Control. Installation and User Manual for BW2/C and BW3/C versions. Quick Guide

Semi flush-mounted room temperature controllers with LCD

Capacity controller for small CO2 booster refrigeration system AK-PC 772 REFRIGERATION AND AIR CONDITIONING. Manual

WinPak 2 & 2005 Quick Reference

UC102 basic version with display and knob UC102BL version with display, knob and backlight UC102DK version without knob and display

VARIA VARIA 826 S WH KNX VARIA 826 S BK KNX D GB F I E NL. Installation and operating instructions Room thermostat VARIA 826 S KNX

Programmable controller MCX152V

Touchpad User Guide. National Sales. Product Support. Freecall: Ph:

Room Temperature Controller with 7-Day Time Switch, LCD and opt. Remote Temperature Sensor

Programmable(5+1+1)Touch Screen LCD Wired Thermostat. General. Features. Operating Algorithm

Model P4470 Save A Watt Operation Manual

E101B SINGLE 7/22/07 10:02 PM Page 1


Installation Guide DEVIlink CC Central Controller

Modulating controlled actuator AME 11

24-hour room temperature controller

Air-Saver. Version: 0403 INDEX

E101B SINGLE 3/2011 Page 1

Capacity controller AK-PC 710. Manual

JKA multi-valve controller

HN1000/HN2000 Product Manual

Data sheet no Data sheet General data sheet Status: 00 hst/ml Distribution: Valid from: Release: Device no.:

Electronic Tap timer Owners Manual

The UP and DOWN buttons will toggle or scroll through the options in each section.

Semi flush-mounted room temperature controllers with LCD

SC2000 MOTOR PROTECTION ELECTRONICS, INC. INSTRUCTION MANUAL. (407) Phone: Website:

REMOTE CONTROL INSTALLATION & OPERATING INSTRUCTIONS

Operation Guide CT32 ENGLISH

Employee Access Guide

Digital time switch SHT-1/2 - two channel - with daily and weekly program. Operating manual. Content. 1. Before you start Features of the device

Brivis Touch. Owner s Manual

Instructions. Installation and Operation of the Prodigy Smart-Board, KSBU

Programmable(5+1+1)Touch Screen LCD Wireless Thermostat. General. Features. Operating Algorithm

Data Sheet A200 Series Electric Actuators

AP41 / AP81 SERIES TIME SWITCHES

ML Multi Stage Thermostat Installation & User Guide

AirTouch 2 Zone Control System

7-day room temperature controller

Operation Guide CT101

Transcription:

MAKING MODERN LIVING POSSIBLE FP735Si Electronic 3-Channel Full Programmer for Heating and Hot Water with Service Interval Timer Danfoss Heating Installation Guide

For a large print version of these instructions please call Marketing on 0845 121 7400. Certification Mark This product complies with the following EC Directives: Electro-Magnetic Compatibility Directive. (EMC) (2004/108/EC) Low voltage Directive. (LVD) (2006/95/EC) Danfoss can accept no responsibility for possible errors in catalogues, brochures, and other printed material. All trademarks in this material are property of the respective companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved. 2 FP735SI

Installation Instructions FP735Si Electronic 3-Channel Full Programmer for Heating and Hot Water with Service Interval Timer Index 1.0 Installation Guide...4 2.0 System Overview...4 3.0 Installation...5 3.1 Removing the wallplate...5 3.2 Installation considerations...5 3.3 Wiring...5 3.3 Mounting the unit...6 3.4 Unit startup...6 4.0 Programming Options...6 4.1 Normal programming...6 4.2 Advanced programming...7 5.0 Pre-programmed Parameters...8 5.1 Advanced programming...8 5.2 Normal programming...8 6.0 Display Information... 10 7.0 Advanced Programming... 11 8.0 Service Interval Timer... 14 9.0 Copy Functions... 14 10.0 The Information Key... 16 11.0 How to Reset The Unit... 16 11.1 Reset... 16 11.2 Full reset... 17 12.0 System Wiring Example... 18 Danfoss Heating 3

1.0 Installation Guide Please Note: This product should only be installed by a qualified electrician or competent heating installer and should be in accordance with the current edition of the IEEE wiring regulations. 2.0 System Overview Timer Features FP735Si Power supply 230V, 50Hz Memory backup Retained for the life of the product Factory set calendar clock Automatic summer/winter time change Switching action of output relay 3 x SPDT, Type 1B Switch rating of relay contact 3(1) A, 230 VAC Rated Impulse Voltage 2.5 kv Dimensions (mm) 140 wide x 91 high x 29 deep Ball Pressure Test 75 C Design Standard EN 60730-2-7 Control Pollution Situation Degree 2 Time accuracy ± 1 minute per month IP rating IP30 Software Classification A 4 FP735SI

3.0 Installation 3.1 First remove the wallplate from the back of the unit. 3.2 From the top left hand corner of the wallplate, there must be clearances of at least 21mm to the right, 21mm to the left, 36mm above and 106mm below in order to mount the plug-in module. 3.3 Wiring 3 on 2 on 2 off 1 on 1 off L N Note: A typical system wiring example is shown on page 18 Danfoss Heating 5

3.4 Mount the unit on the wallplate Note: Always switch the mains off first and never fit/remove the timer to/from a live wallplate. 3.5 With the unit powered up, it is recommended to press and release the RESET button to start up the FP735Si unit. 4.0 Programming Options FP735Si is delivered with a set of parameters that have been preprogrammed to cover the most typical type of installations. See (5.0). If a different parameter setup is wanted the unit provides two programming options: 4.1 Normal programming Normal Programming is meant for setting the timing profile that controls the ON and OFF periods for the room heating and for the hot water. A daily profile may be programmed and a profile can control the entire week where the weekend may be handled separately. Also a timing profile for a holiday can be entered. As part of the normal daily operations, a simple one-button press (+HRS) can extend a running ON period for room heating and/or hot water by one hour. This can be repeated 3 times giving up to 3 hours extension. 6 FP735SI

By pressing ADV (advance), the user can jump to the next event in the daily timing profile. If for instance, the user wants to bring on the room heating immediately whereas the profile has been programmed to bring it on in two hours, the user can simply press ADV and the heat will be turned on. See the User Guide for normal programming instructions. 4.2 Advanced Programming Advanced Programming is meant for changing certain parameters that are usually only set once. Advanced Programming can typically be made by the installer as part of the system installation and setup. Danfoss Heating 7

5.0 Pre-programmed Parameters FP735Si is delivered with a set of pre-programmed parameters. 5.1 Advanced Programming The following pre-programmed parameters can be changed in the Advanced Programming: Function/parameter Pre-programming A+B days (disabled, enabled) Disabled Copy functions Standard (standard or advanced copy function) Summer/winter shift Automatic (automatic or manual) Backlight (always off, always on, 15s after last key press 15s after last key press) 4 events or 6 events per day 6 events Operating mode 7 days (7 days, 24 hours, 5 + 2 week days) Keyboard lock (locked, not locked) Not locked Service interval (disabled, enabled) Disabled Note: for the UK market, the FP735Si comes with a default 12 hours clock (AM/ PM) setup. 5.2 Normal Programming The following pre-programmed parameters can be changed in the Normal Programming. See User Guide. 8 FP735SI

Pre-programmed ON and OFF periods for 6 events per day: Weekdays (Monday-Friday): Event Time Room heating/water heating status 1 06:30 ON 2 08:30 OFF 3 11:30 ON 4 13:30 OFF 5 16:30 ON 6 22:30 OFF Weekends (Saturday-Sunday): Event Time Room heating/water heating status 1 07:30 ON 2 09:30 OFF 3 11:30 ON 4 13:30 OFF 5 16:30 ON 6 22:30 OFF Pre-programmed ON and OFF periods for 4 events per day Weekdays (Monday-Friday): Event Time Room heating/water heating status 1 06:30 ON 2 08:30 OFF 3 16:30 ON 4 22:30 OFF Weekends (Saturday-Sunday): Event Time Room heating/water heating status 1 07:30 ON 2 09:30 OFF 3 16:30 ON 4 22:30 OFF Danfoss Heating 9

6.0 Display Information Channel Status (Event number when programming) Channel Number TIME Days of Week (Numbers or Text) KEY TO SYMBOLS Flame: shows when heating is on Hourglass: shows during programming delays Padlock: indicates keyboard is locked Suitcase: indicates Holiday Mode is set Clock: Timed Modes Hand: Manual Modes Alarm: Indicates alarm is active. Also used for service due 3 on and 3 off events per day 2 on and 2 off events per day 1 on and 1 off event per day. All Day Mode Timer (OFF) Mode + HRS: Extends function by 1, 2 or 3 hours Timer (ON) Mode 10 FP735SI

7.0 Advanced Programming To access the Advanced Programming follow the steps below: a) Press and hold PROG and V for 5 seconds. The display will change to look like this. Parameter setting Parameter number b) Press the + and - keys to scroll backwards and forwards between parameters. Press the V and Λ keys to change the parameter setting. The flashing digits in the center of the display indicate the number of the selected option. The large characters in the top or bottom of the display indicate the option value selected. c) Press and hold PROG until the display returns to RUN mode. Danfoss Heating 11

In the Advanced Programming mode, the following parameters can be changed: Parameter1 Enable/Disable A+B Days This allows the unit to operate in A+B days. A and B days can be grouped arbitrarily: 5+2, 4+3, etc. The days do not have to run in sequence. Press + until parameter 1 is displayed. Press V or Λ to select the required setting. Note: A+B setting is only possible if operating mode 5+2 has been set in Advanced Programming. WARNING: Changing this parameter will reset event times to default values. 0 = disabled (default) 1 = enabled Parameter 2 Copy functions This parameter sets the unit to operate with the Standard Copy function or the Advanced Copy function. Press + until parameter 2 is displayed. Press V or Λ to select the required setting. Note: Advanced Copy setting is only possible if operating mode 7 day has been set in Advanced Programming. 0 = Standard Copy (default) 1 = Advanced Copy Parameter 3 Summer/winter The Summer/winter parameter makes it possible to let the unit change between summer and winter period automatically or manually. The parameter can also disable the change between summer and winter. Press + until parameter 3 is displayed. Press V or Λ to select the required setting. 0 = disable summer/winter change 1 = enable manual summer/winter change 2 = enable automatic summer/winter change (default) 12 FP735SI

Parameter 4 Backlight The backlight parameter allows the backlight to be always on, always off, or on for 15 seconds after the last key press. Press + until parameter 4 is displayed. Press V or Λ to select the required setting. 0 = backlight always off 1 = backlight on for 15 seconds after the last key press (default) 2 = backlight always on Parameter 5 Number of events per day This parameter sets the unit to operate with 4 or 6 events per day. An event being an ON or an OFF period of room heating and/or hot water heating. Press + until parameter 5 is displayed. Press V or Λ to select the required setting. WARNING: Changing this parameter will reset event times to default values. 2 = 2 ON/OFF periods per day 3 = 3 ON/OFF periods per day (default) Parameter 6 Operating Mode (7 Day, 5+2 Day or 24 Hour) This parameter sets the unit to operate using either 7 day, 5+2 day or 24 hour mode. Press + until Option 6 is displayed. Press V or Λ to select the required setting. WARNING: Changing this parameter will reset event times to default values. 24 = 24 hour 5-2 = 5+2 Day (or A+B if set in parameter 1) 7 = 7 day (default) Danfoss Heating 13

Parameter 7 Keyboard Lock This parameter sets the unit to operate with an enabled (functioning) or a disabled (locked) keyboard. Press + until parameter 7 is displayed Press V or Λ to select the required setting. 0 = the keyboard is enabled (default) 1 = the keyboard is disabled (locked) 8.0 Service Interval Timer The FP735Si is equipped with an installer setback service interval timer. If this feature is required please contact our technical department. Setting instructions for this gas safety feature are only available to bona fide heating installers. 9.0 Copy Functions FP735Si provides 3 copy functions: Standard Copy, Advanced Copy and Channel Copy. Standard Copy is the default setting. If the Advanced Copy function is wanted, it must be changed in Advanced Programming mode (page 13). Channel Copy is always available. Standard Copy Pressing COPY/i will copy the previous day s events into the displayed day. The unit will then display the 1st event for the new day. The Standard Copy function is only present if the unit is set to run in 7 day mode, or 5+2 day mode. 14 FP735SI

To perform a standard copy operation: a) Press CH to select the channel. b) Press PROG to go to event programming. c) Press DAY/HOL to select the day to copy to. d) Press COPY/i to copy the previous day s events to the displayed day. Advanced Copy The Advanced Copy function is available in 7 day mode only. This allows any day to be copied to any other day, or days. To use the Advanced Copy function, go into the event programming using the PROG button, then: 1) Press DAY/HOL to select the day to be copied from. 2) Press COPY/i to copy from the selected day. When selected, the day will begin to flash. 3) Press DAY/HOL to select the day to be copied to. 4) Press COPY/i to copy to the selected day. 5) Repeat steps 3 and 4 to select and copy other days. 6) To stop copying, use the DAY/HOL button to go back to the flashing day and press the COPY/i button. The previously flashing day will stop flashing to indicate it has been de-selected. NOTE: When a day has been copied to, it will remain visible and not flashing when the DAY/HOL button is used to select other days. Channel Copy Channel Copy is used to copy events from one channel to another channel. To perform a Channel Copy operation: a) Press CH to select the channel to copy to. b) Press COPY/i to copy from the previous channel. Danfoss Heating 15

10.0 The Information Key When running in normal operation, the Information key COPY/i will provide the following information: 1 st COPY/i key press: the model number is displayed. 2 nd COPY/i key press: the software version is displayed. 3 rd COPY/i key press: the next event time is displayed. 4 th COPY/i key press: the Service Due end date is displayed (if set). In holiday mode, the information key will provide the holiday end date only. Note: the first COPY/i key press will only turn on the backlight if no keys have been pressed for 2 minutes. 11.0 How to Reset The Unit FP735Si has three levels of reset: Reset Full Reset 11.1 Reset Reset restores operation in the unlikely event that the unit has become unresponsive. Press and release the RESET button. 16 FP735SI

This does not reset any programmes or the time or date, but will cancel any manual overrides that have been selected. 11.2 Full Reset 1) Go to Advanced Programming: press and hold PROG and V for 5 seconds. 2) Press and hold PROG and press/release R/S. At a Full Reset: Event times are reset to their default values (section 5.2). Next event overrides are cancelled. +HRS overrides are cancelled. Pre-programmed Parameters (see 5.1) are reset to default values. Time and date are not changed. Danfoss Heating 17

12.0 System Wiring Example 3.3 For wiring connections please refer to the diagram below: Links to be made by installer HW Zone 2 Zone 1 Permanent links 3on 2on 2off 1on 1off L N 10 16 9 L N Wiring Box - WC4B 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 L N L N 12 4 N 6 7 3 2 Perm L N Sw. L Brown Blue Orange Grey 3 2 RET B Boiler * Out In RMT230 1 2 4 Aux. Sw. Motor L N RET230 L 3 N HP22 2 Port Valve (Heating Zone 1) COM CALL N 18 FP735SI

Room Thermostat - Zone 1 13 N 5 N 6 7 L N Brown Blue Orange Grey 16 1 Pump * Out In Aux. Sw. Motor L N RET B 3 2 HP22 2 Port Valve (Heating Zone 2) 8 N 6 7 ATC RMT230 RET230 1 2 4 L 3 N COM CALL N 3 2 1 Brown Blue Orange Grey Room Thermostat - Zone 2 Out In 14 15 Aux. Sw. Motor L N HP22 2 Port Valve (Hot Water) The above wiring diagram refers to a 3 Zone system using 3x2 port valves to control flow to each heating zone and the hot water. For systems using 3 port valves or a combination of 2 and 3 port valves please consult your local Danfoss contact. * Refer to boiler wiring information for boilers with pump overrun Danfoss Heating 19

Danfoss Ltd. Ampthill Road Bedford MK42 9ER Tel: 0845 1217 400 Fax: 0845 1217 515 Email: ukheating@danfoss.com Website: www.heating.danfoss.co.uk Part No. 013R9577/VIHVC202-03/2014