1 Series Data Logger / Thermometer Thermocouple Types: K/J/T/E/R/S/N Software Manual
Operation Table of Contents... index 1. RS232... index 2. REC... 1 3. CALL... 1 4. CLEAR... 2 5. INTV (RS232)... 3 6. INTV (REC)... 4 RS232... 5 1. Sensor Form... 5 2. Temperature Value Form... 6 3. Transmit The Form... 6 RS232 Software Installation Procedure... 7 RS232 Operation of Software... 8 Operation 1. RS232: Turn on RS232 function, the meter and PC application program communication. When turn on RS232 function, the auto power off will be canceled and the power off will be canceled, too. For RS232 or Data Logger models. A Step 1 RS232 PC Step 2 RS232 Back to main display
2. REC: Turn on REC function, the reading value of meter, according to transmitting the settlement of interval time, will write down in the memory real time. Can write down 10000 records at most. When turn on REC function, the auto power off will be canceled, and the power off will be canceled too. When the memory is filled, the display will appear ou word (for Data Logger models). A Step 1 REC REC REC OU Memory is Filled Back to main display REC Step 2 3. CALL: Can inquire that the data of every channel, can also inquire about the surplus space of the memory. For Data Logger models, each time entering to inquire data by the last. When turn on CALL function, the auto power off will be canceled. A T3 50 T2 30 T4 40 Step 1 CALL 2205 CALL 1000 1:00 h:m Last Number Date Time A. Use, key to choose channel B. Use, key to choose number hold or key above 1 second, the readout rate will be added, about 50 numbers/second. See Next Page Page 1
See Previous Page Step 2 2205 CALL 1000 22:05 h:m Step 3 CALL BYTE 1293 2205 2004 y Surplus Space Date Year Back to Step 1 Step 5 CALL BYTE 1293 2205 2004 y Step 4 4. CALL Remove the record of the memory (for Data Logger models). A T3 50 T2 30 T4 40 Step 1 A T2 30 T3 50 T4 40 Step 2 CALL CLEA CALL Step 3 CALL CLEA Back to main display Page 2
RS232 5. Carry out the RS232 interval setting. The biggest settlement time is 59 minutes and 59 seconds. Minimum to set for time is one second. Enter and show 00:01 seconds of initial value for the first time. Enter and show settlement value last time for the second time after (for RS232 or Data Logger models). Back to main display A T3 50 30 T4 T2 40 PC INTV 00:02m:s Step 1 A T3 50 30 T4 T2 40 Step 2 RS232 PC INTV 00:01m:s PC INTV 00:01m:s Page 3
REC 6. Carry out the record interval setting. The biggest settlement time is 59 minutes and 59 seconds. Minimum to set for time is one second. Enter and show 00:01 seconds of initial value for the first time. Enter and show settlement value last time for the second time after (for Data Logger models). Back to main display A T3 50 30 T4 T2 40 REC INTV 00:02m:s Step 1 A T3 50 30 T4 T2 40 Step 2 REC REC INTV 00:01m:s REC INTV 00:01m:s Page 4
RS232 Data Form Model - 0 Data Form: 1. Sensor Form: (1) SEN 1 SEN 2 7 43 0 7 43 0 T4 T3 T2 Sensor Date K J T E R S N 0 1 2 3 4 5 6 (2) SEN 1 7 43 0 T4 T3 Bit 0~3: Sensor Kinds That Can Be Used 0: K 1: K/J 2: K/J/T 3: K/J/T/E 4: K/J/T/E/R 5: K/J/T/E/R/S 6: K/J/T/E/R/S/N Bit 4~5: Sensor Kinds That Can Be Used 0: 1:, T2 2:, T2, T3 3:, T2, T3, T4 Bit 6: Model: (0: ~T4 Type Adjustable, 1: only Type Adjustable) Bit 7: Unused Page 5
Model - 0 Data Form: Transmit the time interval: Max 59 minutes 59 seconds 1 0 7 43 0 7 43 0 Minute (decimal) Second (decimal) 2. Temperature value form?_decf3?_decf2?_decf1 7 43 0 7 43 0 7 43 0 Bit 4: Positive, Negative (Positive: 0, Negative: 1) Bit 5: Overflow Integer (decimal)?_decf1?_decf0 7 43 0 7 43 0 Fraction (decimal) 3. Transmit the Form L.C. C.C. S.C. Date E.C. L.C. C.C. S.C. Flag E.C. L.C. E.C. : 0AA : 0AB C.C.~ 0BX : Model-0 0B1 : Sensor, T.I. Temperature (Terminal -> PC) 0B2 : Sensor & T.I. (Terminal -> PC) 0B3 : Sensor & T.I. (PC -> Terminal) 0B4 : Data = 10, on-line confirm (PC -> Terminal) 0B9 : Answer 0B1 (PC -> Terminal) 0BA : Answer 0B2 (PC -> Terminal) 0BB : Answer 0B3 (Terminal -> PC) Page 6
Model - 0 Data Form: Transmit the time interval: Max 59 minutes 59 seconds S.C.~ Flag: Order code (00 ~7F ). The same data conveyed repeatedly, the code does not change. On the contrary, different data, this code add one in order. 30 = fail, 31 = success Data: C.C. = 0BX SEN 0~2, 0~1, Tn0* Tn0*: _DECF1~3, _DECF0, T2_DECF1~3, T2_DECF0, _DECF1~3, T3_DECF0, T4_T3DECF1~3, T4_DECF0 RS232 Software Installation Procedure 1. Put CD-R into CD-ROM driver. 2. Install way with can divided into automatic installation and manual installation in accordance with the personal software. The manual installation is: A. Pushing my my computer, the mouse clicked two times. B. Pushing CD-ROM driver, the mouse clicked two times. C. Pushing setup file, the mouse clicked two times. Beginning to enter installation procedure. 3. Begin to install picture: 4. Choose to install path: Page 7
5. Choose program setup: 6. Install progress: 7. Install completed: RS232 Operation of Software Page 8
Page 9
Page 10
Page 11
Page 12