LifeSize ClearSea Installation Guide August 2012

Similar documents
LifeSize UVC Platform Installation and Deployment Guide December 2013

Lifesize Icon Installation Guide October 2016

350 East Plumeria Drive San Jose, CA USA May

350 East Plumeria Drive San Jose, CA USA February

Unified Office Gateway UMG Quick Installation Guide. Version: 1.0

ReadyNAS OS 6 Rack-Mount Hardware Manual

16Hi HARDWARE INSTALLATION GUIDE

The list below shows items not included with a SmartVDI-110 Server. Monitors Ethernet cables (copper) Fiber optic cables Keyboard and mouse

Manager Appliance Quick Start Guide

M1032W Engineering Workstation. The list below shows components included in an M1032W Engineering Workstation container.

M1034W Engineering Workstation

Installation and Configuration Guide

HP UPS R/T3000 ERM. Overview. Precautions. Installation Instructions

Junos WebApp Secure 5.0 Hardware Guide

Introducing the Cisco 1121 Secure Access Control System Hardware

VelaSync HIGH-SPEED TIME SERVER. Quick Reference Guide

Installation and Configuration Guide

Juniper Secure Analytics Quick Start Guide

HARDWARE INSTALLATION GUIDE. Arcserve UDP 8100 and UDP 8200 Appliance Hardware Installation Guide

Cisco CRS 3-Phase AC Power Distribution Unit Installation Guide 2. Cisco CRS 3-Phase AC Power Distribution Unit 2

Arcserve UDP 8100 and UDP 8200

PRISMA VelaSync HIGH-SPEED TIME SERVER. Getting Started Guide

Panzura Freedom Filer Installation Guide

PIX 515/515E. PIX 515/515E Product Overview CHAPTER

Install the Cisco SNS 3415 and Cisco SNS 3495 Hardware Appliances, page 1

LVN5200A-R2, rev. 1, Hardware Installation Guide

The Vision of Security

HP UPS R/T3000 G2. Overview. Precautions. Kit contents. Installation Instructions

Thank you for selecting UTC RETAIL s innovative Model 1170 Point of Sale solution!

Installation and Configuration Guide

2U Server. User Manual

ZOTAC ZBOX User s Manual

GS-SR104 Rack Mount Server System Installation Guide

G3-APEX-ENT-32T. Apex technical specifications. Parts list

L2+ 24-Port Gigabit Managed Switch with. Hardware Layer3 IPv4/IPv6 Static Routing GS S8C GS S8CR. Quick Installation Guide

Compaq Ultra-Dense Server Deployment in Telecommunications (Telco) Racks

Quick Installation Guide

IBM. Rack Installation Instructions

Upgrading and Servicing Guide

Rack Installation Instructions

Quick Installation Guide

Rocsecure NE52 NAS System

Installing the Cisco MDS 9020 Fabric Switch

Next Generation Firewall

Alienware Area-51 R5 Service Manual

Quick start guide for i5 520 ( or )

Colorful Technology Website:

VMware ESX ESXi and vsphere. Installation Guide

Polycom RealPresence Capture Server - Appliance Edition Getting Started Guide

Cisco VDS Service Broker Software Installation Guide for UCS Platforms

Installing the IPS 4345 and IPS 4360

ReadyNAS Rack-Mount Storage Systems

Quick start guide for p5 520 ( )

Installation of the POTS splitter card requires the following steps: Determining the cables you need. Installing the POTS splitter chassis

Installing the Cisco Unified Videoconferencing 3545 MCU

Installing and Managing the Switch

ZOTAC ZBOX. User s Manual

Table of Contents. 1. Introduction Package Contents Function Installation Web Interface... 4

Dell OptiPlex SFF AIO Stand. User s Guide. Model: IKAIO-01 1 /13

L2+ Managed Gigabit/10 Gigabit Ethernet Switch GS-5220 Series

Polycom RAS200A. Getting Started Guide

H4 Series Hardware Replacement Guide

ZOTAC ZBOX nano. User s Manual

Tilgin Home Gateway HG321/HG322 HG320 Series Quick Guide

Deploy a Customer Site

Quick Installation Guide

OneSign Virtual Appliance Guide

WatchGuard XTMv Setup Guide

DX Application Acceleration Platform Quick Start

742S 742i SC742 CHASSIS USER'S GUIDE

Upgrading and Servicing Guide

QK5P1000-Manual_Cover-135x135mm_PrintReady.eps 1 2/7/ :52:09 AM CMY 291-MB384-01S4F

HP R/T2200 UPS. Overview. Precautions. Installation Instructions. The HP UPS R/T2200 features power protection for loads up to 2200 VA/1600 W.

HP ProLiant SL160z G6 Server

McAfee Network Security Platform

Aruba JL311A Cable Guard Installation Instructions

PIX 520. PIX 520 Product Overview CHAPTER

ZOTAC ZBOX nano. User s Manual

Citrix NetScaler 10 Quick Start Guide: MPX 5500 Platform

User Manual. Per Port Monitoring Models

291-MB309-02N6F. PI331 pico

Hardware Replacement Guide

Stonesoft Next Generation Firewall. Hardware Guide Models 5201, 5205, Revision C

G3-GS-4P-16T. Parts list G3-GS-4P-16T technical specifications. The G3-GS-4P-16T is best suited for small data centers or at your network edge.

Catalyst 2360 Switch Getting Started Guide

Preparing to Install the VG248

Product Version 1.1 Document Version 1.0-A

ZOTAC ZBOX User s Manual

Hardware Replacement Guide Types 8099, 8116, 8155, 8156 Types 8157, 8158, 8159, 8160 Types 8215, 9210, 9211

CAD-0225 Series Communication Appliance. User Manual Revision: 1.0

Cisco NAC Appliance Hardware Platforms

HP ProLiant DL165 G7 Server

Sun StorageTek. 1U Rackmount Media Tray Reference Guide. Sun Doc Part Number: Second edition: December 2007

Cisco 200 Series Smart Switches. Quick Start Guide

64 Bays SAS to SAS/SATA JBOD Subsystem. User Manual. Revision 1.0

Install your TPS 440T and 2200T security devices

64-Ch Windows-based NVR. with 8-Bay Hard Disks NVR-E6480. Quick Installation Guide

1.1.Packing Contents 1*Colorful C.B250A-BTC V20 motherboard 2*SATA cables 1*Driver/Utility CD 1*User's Guide 1*I/O shield 1.2.MOTHERBOARD SPEC CPU

Internet Telephony PBX System. (30/100/200/500 SIP Users Registrations) IPX-330/IPX-2100/IPX-2200/IPX Quick Installation Guide

Rack Installation Instructions

Transcription:

LifeSize ClearSea Installation Guide August 2012 LifeSize ClearSea LifeSize ClearSea Virtual Machine

LifeSize ClearSea Installation Guide 2 LifeSize ClearSea This guide describes how to install and configure LifeSize ClearSea hardware and the LifeSize ClearSea virtual machine. Installing Troubleshooting Describes the installation and rack mounting process for LifeSize ClearSea. Describes the installation process for the LifeSize ClearSea virtual machine. Provides instructions for accessing the server console and replacing faulty drives. LifeSize ClearSea LifeSize ClearSea Virtual Machine Troubleshooting The server s network location determines who can access the server and how you must configure your firewall. Refer to the LifeSize ClearSea Administrator Guide for a discussion of firewall implications and initial configuration steps. Related documentation is available from lifesize.com/support.

LifeSize ClearSea Installation Guide 3 Section 1: LifeSize ClearSea LifeSize ClearSea ships with the following components: 1U (44.45 mm, 1.75 ) rack-mountable LifeSize ClearSea Server face plate and key rack rail hardware: - two front inner rails (attached to the server chassis) - two rear inner rails for the chassis - two rails for the rack - one bag of brackets and screws power cord For best performance, use Category 6 Ethernet cables (not included) to connect LifeSize ClearSea to your network. At minimum, use Category 5e cables. Choose a clean, dust-free, well-ventilated location near a grounded power outlet. Avoid areas where heat, electrical noise, and electromagnetic fields are generated. If you intend to mount the server in a rack, refer to Installing LifeSize ClearSea into a Rack. LifeSize recommends that you install the server on a non-lossy gigabit Ethernet network for optimal performance. Installing LifeSize ClearSea Before you install LifeSize ClearSea, read the Safety and Regulatory Notices for important safety information. 1. Remove all components from the product packaging and place them in the desired position in your environment. 2. If applicable, follow the instructions in Installing LifeSize ClearSea into a Rack before continuing. 3. Insert a network cable from your LAN into the left network port as you face the back panel of the server. This is the Internal (LAN) interface. By default this interface uses DHCP. 4. Insert a network cable into the right network port as you face the back panel of the server. This is the external (WAN) interface. By default, the IP address for this interface is 192.168.0.99, and the network mask is 255.255.255.0 5. Insert one end of the power cord into the back of the server and the other end into a power outlet on the wall. 6. Press the power button on the front of the server. Refer to Power and Reboot.

LifeSize ClearSea Installation Guide 4 7. Attach the face plate: a. Fit the left side of the face plate into the slots on the front of the server. b. Press and hold the release button, place the right side of the face plate against the front of the server, and release the button to lock the face plate into the slots. c. Lock the face plate to the chassis with the key. 8. From a computer on your LAN or a computer connected directly to the WAN Ethernet cable, open a browser and enter the IP address for the server, and then follow the initial configuration instructions in the LifeSize ClearSea Administrator Guide. NOTE If you cannot access the server through a browser, refer to Local Console Access for instructions about using the local console. Installing LifeSize ClearSea into a Rack Use the included rack rail hardware to install LifeSize ClearSea into your rack. The rack mounting procedure may vary according to rack type. Refer to the installation instructions included with your rack in conjunction with these instructions. Consider the following as you plan the rack installation: Rack Stability Airflow and Access Ambient Operating Temperature Circuit Overloading Reliable Ground Ensure that the leveling jacks on the bottom of the rack are fully extended to the floor with the full weight of the rack resting on them. In a single rack installation, attach stabilizers to the rack. In multiple rack installations, couple the racks together. Leave approximately 63.5 centimeters (25 inches) of clearance in front of the rack and approximately 76 centimeters (30 inches) of clearance in back of the rack to allow for sufficient airflow and ease in servicing. If you install LifeSize ClearSea in a closed or multi-unit rack assembly, the operating temperature of the rack environment might be greater than the ambient temperature of the room. The maximum operating temperature is 35 degrees Celsius. Consider the connection of this equipment to the power supply circuitry and the effect that it might have on overcurrent protection and power supply wiring. Give appropriate consideration to equipment nameplate ratings when addressing this concern. Because a reliable ground must be maintained at all times, ensure that the rack itself is grounded. Pay particular attention to power supply connections other than the direct connections to the branch circuit (the use of power strips, for example). Attach the rear inner rails to the server chassis and the rack rails to the rack.

LifeSize ClearSea Installation Guide 5 Installing the Rear Inner Rails 1. Beginning with the rail for the right side of the chassis as you face the chassis, align the two square holes on the rail against the hooks on the right side of the chassis. 2. Securely attach the rail to the chassis with the flat head screws provided. 3. Repeat the previous steps to install the left rear inner rail to the left side of the chassis. The chassis rails have locking tabs that lock the server into place when it is pushed fully into the rack (its normal operating position). These tabs also lock the server in place to prevent the server from coming completely out of the rack when you extend it for servicing. Installing the Rack Rails in Non-Telco Racks 1. Position a chassis rail guide (rack rail) in the desired location in the rack. Keep the sliding rail guide facing the inside of the rack. 2. With screws appropriate for the rack, attach the assembly securely to the rack by using the brackets provided with the rack rails. 3. Attach the other assembly to the opposite side of the rack. Ensure that both assemblies are at the same height and that their rail guides face inward.

LifeSize ClearSea Installation Guide 6 Installing the Rack Rails in Telco Racks Use two of the provided L-shaped brackets on either side of the rack (four total) to attach the rack rails to a telco-type rack. 1. Using screws appropriate for the rack, attach a bracket to the front and rear of one side of the rack at the same height. 2. Position the rail for one side of the rack so that the server will be stable when locked into place. Keep the sliding rail guide facing the inside of the rack. 3. Attach the rack rail to the brackets on the rack, using the screws provided. 4. Repeat the process for the opposite rail. Placing the Server into the Rack After you attach rails to both the chassis and the rack unit, place the server into the rack. 1. Line up the rear of the chassis rails with the front of the rack rails. 2. Slide the chassis rails into the rack rails. Keep the pressure even on both sides. (You might have to depress the locking tabs while inserting the rails.) 3. Push the server completely into the rack until you hear the locking tabs click.

LifeSize ClearSea Installation Guide 7 Power and Reboot The faceplate covers the reset and power buttons on the server chassis. Remove the faceplate to use these buttons. The reset button on the front panel reboots the server. The power button controls the main system power. Turning off the system power removes the main power, but standby power remains available to the system while it is connected to the power line. WARNING Using the reset button initiates a hard reboot of the server. Instead, reboot and power down the server from the web administration interface. Use the reset and power buttons on the server only if the web administration interface is unresponsive. LED Status The LED indicators on the server indicate the following conditions: LED Icon Indicator Overheat/Fan Failure NIC2 When flashing, indicates a fan failure. When on continuously, the LED indicates the server is overheated, which might be caused by cables obstructing the system airflow or high ambient room temperature. Ensure that the chassis cover is installed securely. This LED remains flashing or on continuously for as long as the condition persists. Reserved for future use. NIC1 When flashing, indicates network activity on LAN1. HDD Power Indicates channel activity for all hard disk drives. When flashing, this LED indicates SATA drive activity. Indicates power is being supplied to the system s power supply unit.

LifeSize ClearSea Installation Guide 8 Section 2: LifeSize ClearSea Virtual Machine Installation Prerequisites Your virtual appliance is delivered as a VM image file for VMware. NOTE You must dedicate resources to the LifeSize ClearSea virtual machine. Check your VMware product documentation for additional requirements. VM Host Software Requirements VMware ESXi v4.1 on the host machine on which you intend to install LifeSize ClearSea Server. VMware vsphere Client v4.1 (Windows only) on the computer from which you intend to access the VMware server. Minimum Hardware and Virtual Machine Requirements Model Host Virtual Machine CS100 CS150 Intel Xeon Nehalem Processor 2 GHz Intel Dual Quad-core Xeon Nehalem E5620 Processor 2.40 GHz 2 VCPUs 2 GB RAM 10 GB free hard disk space 2 network adapters 8 VCPUs 3 GB RAM 10 GB free hard disk space 2 network adapters

LifeSize ClearSea Installation Guide 9 Installing the LifeSize ClearSea Virtual Machine NOTE Consult with your LifeSize representative for license options and trials. 1. Copy the LifeSize ClearSea virtual machine.ova file to the host machine. 2. Start the VMware vsphere Client and use the following credentials to log in to the server: - IP address of the VMware ESXi server - administrator username and password 3. From the VMware vsphere Client, select the server: Home > Inventory. 4. Select File > Deploy OVF Template. 5. Click Browse to select the virtual machine you copied in step 1. 6. Follow the prompts to install the LifeSize ClearSea virtual machine. 7. Adjust the settings to ensure that the virtual machine meets the VCPU, memory, and disk space requirements in Minimum Hardware and Virtual Machine Requirements. CS150 only: Depending on your operating system, you might be required to configure the number of cores for each VCPU. From the VMware vsphere Client, edit the virtual machine: a. In Hardware, set the number of virtual CPUs to 8. b. In Options : Advanced - General, click Configuration Parameters to add a new cpuid.corespersocket parameter. c. Set the value of the new parameter to 2, 4, or 8, depending on the number of cores per socket. Refer to the the VMware knowledge base article 1010184 for more information. 8. Power on the virtual machine. 9. From a computer on your LAN or a computer connected directly to the WAN Ethernet cable, open a browser and enter the IP address for the server. Follow the initial configuration instructions in the LifeSize ClearSea Administrator Guide. By default the LAN IP address is determined by DHCP, and the WAN IP address is 192.168.0.99, with the network mask of 255.255.255.0. NOTE If you cannot access the server through a browser, refer to Local Console Access for instructions about using the local console.

LifeSize ClearSea Installation Guide 10 Section 3: Troubleshooting Local Console Access If you cannot access the server through the web administration interface, access the console: From the hardware appliance: Connect a monitor directly to the VGA output on the back of the server, and connect a keyboard directly to the server with USB or PS/2 connectors. From VMware: Use the emulated system console provided by VMware. NOTE The local console has very restricted functionality and should only be used to set up the network for the first time to access the full web-based Control Panel, or to recover administrative passwords. The local console will also show your system ID in the upper-right corner of the user interface. If the local console is locked, enter the following credentials: username : console password : console

Copyright Notice 2012 Logitech, and its licensors. All rights reserved. LifeSize, a division of Logitech, has made every effort to ensure that the information contained in this document is accurate and reliable, but assumes no responsibility for errors or omissions. Information in this document is subject to change without notice. Companies, names, and data used in examples herein are fictitious unless noted. This document contains copyrighted and proprietary information which is protected by United States copyright laws and international treaty provisions. No part of the document may be reproduced or transmitted, in any form or by any means, electronic or mechanical, for any purpose, without the express written permission from LifeSize Communications. Trademark Acknowledgments LifeSize, the LifeSize logo and other LifeSize marks, are owned by Logitech and may be registered. All other trademarks are the property of their respective owners. Patent Notice For patents covering LifeSize products, refer to lifesize.com/support/legal. Contacting Technical Services LifeSize Communications welcomes your comments regarding our products and services. If you have feedback about this or any LifeSize product, please send it to feedback@lifesize.com. Refer to lifesize.com/support for additional ways to contact LifeSize Technical Services.