A66SM Installation and Programming Manual

Similar documents
A66N2 Installation and Programming Manual

Optidrive Applications Support Library

Tongta Inverter TDS-F8

Optidrive Applications Support Library

Installation and Programming Manual

3GV M Modbus RTU Register Map

E2 Modbus RTU Register Map Revision History Version Comments Author Date 1.02 Previous version PAE 11/06/ Revised to new format PAE 09/03/09

E2 Modbus RTU Register Map

GV3000/SE AC Drive Quick Reference Version 6.06

Display / Adjustment Options VW3-A16101, VW3-A16102, VW3-A16103

Quick Start Guide For GVX9000 AF Drives

Firmware Manual - EC Series Drives

Optidrive VTC Modbus RTU Register Map

Unidrive M200, M201 (Frame 1 to 4) Quick Start Guide

QUCM Limitorque Controller

Tracer Summit. Interface to Square D Drives BAS-PRC004-EN. June 2000

Unidrive M400 (Frame 1 to 4) Quick Start Guide

Metasys N2 Instruction Manual VLT Adjustable Frequency Drive. 12/ Revision B

ATV12HU22M3 variable speed drive ATV12-2.2kW - 3hp V - 3ph - with heat sink

ATV12P075M3 variable speed drive ATV kW - 1hp V - 3ph - on base plate

ATV630U15N4 variable speed drive ATV kW/2HP V - IP21/UL type 1

DEB Setup Video. Niobrara Research & Development Corporation P.O. Box 3418 Joplin, MO USA

ATV12P037F1 variable speed drive ATV kW hp V - 1ph - on base plate

MODERNIZE YOUR DC CRANES. Convert Your DC Controls to State-of-the-Art Energy Efficient OmniPulse DDC Series 2 Drives

Step 1: Choose the Appropriate CPU Step 2: Make the Connections

ATV12H075M3 variable speed drive ATV kW - 1hp V - 3ph - with heat sink

ATV12H018M2 variable speed drive ATV kW hp V - 1ph

VS mini J7 to J1000 Replacement Instructions

Quick Start Guide Cutler-Hammer SVX9000 Drives from Eaton Corporation CONTENT STEP 1 Keypad Operation Overview STEP 2 Standard Wiring Diagrams and

AC Variable Speed Drive 0.75kW 250kW / 1HP 350HP Volt 1 & 3 Phase. Advanced User Guide Revision 1.10

LULC031 Telemecanique

MODBUS PLUS TO SIEMENS G110/G120/MM440 APPLICATION

Installation and Programming Manual. This Manual describes the IBSS InterBus-S Slave, its uses and set up.

EQ5 SERIES Quick Start Guide for Constant Torque Applications

Altivar 21 Programming and Operation Guide

Altivar 68. Coupleur de communication Protocole Modbus Communication coupler Modbus protocol VW3-A Guide d'exploitation User's manual

ATV930U30M3 variable speed drive - ATV930-3kW - 200/240Vwith braking unit - IP21

DEB SY/MAX Video. Niobrara Research & Development Corporation P.O. Box 3418 Joplin, MO USA

Unico 2400 Drive Faults Descriptions and Causes Dec. 2016

SMD SERIES INVERTER MODBUS CONTROL OPERATION MANUAL. Document: SLmod-e2

CHAPTER MAINTENANCE AND TROUBLESHOOTING. In This Chapter... Maintenance and Inspection Troubleshooting...6 3

ATV32HU75N4 variable speed drive ATV kw V - 3 phase - with heat sink

GV3000/SE General Purpose (Volts/Hertz) and Vector Duty AC Drive, HP, 230V AC

Installation and Programming Manual. Niobrara Research & Development Corporation P.O. Box 3418 Joplin, MO USA

ATV61HC31Y variable speed drive ATV61-310kW - 690V - without EMC filter

Installation and Programming Manual

ATV310HU30N4E variable speed drive ATV310-3 kw - 4 hp V - 3 phase

MC Series Drives. Flexible, simple, rugged, robust!

Copyright: December 2017 Nidec Issue: E

ATV32HU11M2437 variable speed drive ATV32-1.1kW 200V - 1P - Bluetooth built-in - w heat sink

MODBUS RTU MODULE INSTRUCTIONS. for use with WSIQ2/WSE

ATV61HU55M3 ATV61 5,5 kw 7,5HP 240V single phase EMC IP20

CNInformation SCHNEIDER ELECTRIC

Standard Options. Model 4100 Position Indicating Meter. Three Phase Motor Control. Positran Transmitter

ATV32HU40N4 variable speed drive ATV32-4 kw V - 3 phase - with heat sink

ATV310H075N4E variable speed drive ATV kw - 1 hp V - 3 phase

Installation and Programming Manual

PART 1: GENERAL PART 2: PRODUCT. Effective: 12/29/10 Page 1 of 6 FECA-TE-104D

Parameter displayed menu (SUP)

1336 PLUS II Quick Start Guide

ATV32HD11N4 variable speed drive ATV32-11 kw V - 3 phase - with heat sink

ATV32H075M2 variable speed drive ATV32-0,75 kw V - 1 phase - with heat sink

LOW VOLTAGE BLDC MOTOR CONTROLLER

AC Variable Speed Drive 0.75kW 250kW / 1HP 350HP Volt 1 & 3 Phase. Advanced User Guide Revision 2.00

ATV32HU30N4 variable speed drive ATV32-3 kw V - 3 phase - with heat sink

Installation and Programming Manual

ATV32HD11N4 variable speed drive ATV32-11 kw V - 3 phase - with heat sink

LiquiFlo AC General Purpose (Volts/Hertz) and Vector Duty Drive Software Start-Up and Reference Manual Version 6.4

ATV32H055N4 variable speed drive ATV kw V - 3 phase - with heat sink

Installation and Programming Manual

Instructions. Modbus RTU Card (WSIQ-COM-MB)

VLT 2800 DRIVE SPECIFICATIONS

Installation and Programming Manual

ATV61HC11N4 SPEED DRIVE 150 HP 460 V ATV61

ATV32HU30N4 variable speed drive ATV32-3 kw V - 3 phase

PowerFlex 700H Drive Firmware (Revision )

User Guide Regenerative & Non-Regenerative Digital DC Drives 5 to 1000 HP

Table of Contents 1. Overview Installation...6

PROGRAMMING MANUAL IM262R00. AQUAVAR Intelligent Pump Controller START-UP GENIE PROGRAMMING MANUAL

Diagnostics and troubleshooting

AC Variable Speed Drive 0.75kW 250kW / 1HP 350HP Volt 1 & 3 Phase. Advanced User Guide Issue 06

ATV650U30N4E variable speed drive ATV650-3kW V - IP55 - disconnect switch

GV3000/SE 230 VAC 1-20 HP General Purpose (Volts/Hertz) and Vector Duty Drive Software Start-Up and Reference Manual Version 6.04

MPU-32 AND FPU-32 TIA-485 NETWORK

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

ATV340D75N4E variable speed drive - 75kW- 400V - 3 phases - ATV340 Ethernet

SAFETY PRECAUTIONS. Throughout this manual we use the following two illustrations to make you aware of safety considerations:

Serial CFW-11. Communication Manual. Phone: Fax: Web:

Instruction Bulletin. ALTIVAR 58 Adjustable Speed Drive Controllers

Reliance GV3000 Drive Registers

Copyright: December 2017 Nidec Issue: E

QUICK REFERENCE GUIDE

MC3000 Series Drives Metasys N2 Communications Guide

ATV320U04N4C variable speed drive ATV kW V - 3 phase - compact

MCD 200 MCD 500. Remove the Profibus Module using the following procedure: 1. Remove power from the module.

Opal Pro AB Ethernet IP. Opal Pro MS6 SERIES. AB Ethernet IP Interface Users Manual. Revision Page 1

Quantum III. Compact DC Drive Package. Slitter DC Drive Package. Quantum III

GS1 Series Introduction

Observe all necessary safety precautions when controlling the soft starter remotely. Alert personnel that machinery may start without warning.

Allen-Bradley Bulletin 1336/1336VT Firmware Feature/Compatibility

Transcription:

A66SM Manual A66SM Installation and Programming Manual This Manual describes the A66SM Communications Adapter for the Altivar 66 Variable Frequency Drive, its uses and set up. Effective: 22 February 1999 Niobrara Research and Development Corporation P. O. Box 3418 Joplin, MO 64803 Telephone: (800) 235-6723 or (417) 624-8918 Facsimile: (417) 624-8920 Internet: http://www.niobrara.com

Altivar, SY/MAX, PowerLogic, and PNIM are trademarks of Square D. Modbus Plus is a trademark of Schneider Automation. Subject to change without notice. Niobrara Research and Development Corporation 1998. All Rights Reserved. 2 A66SM Manual

Contents CONTENTS...3 1 INTRODUCTION...5 2 INSTALLATION...7 3 OPERATION...9 A66SM Manual 3

1 Introduction The A66SM communications adapter card connects an Altivar 66 variable frequency drive controller (see Figure 1 below) to a SY/MAX PowerLogic or PNIM multidrop network. It will allow the PowerLogic or PNIM bus master to adjust drive operational parameters, command, control, and monitor drive operation, and diagnose drive fault conditions. The A66SM is a Type 3 PCMCIA card with an attached 3 meter cable terminated with a 15- pin D-Sub connector. The A66SM is designed to operate in the PCMCIA slot of an I/O extension module (VW3A66201T or VW3A66202T) or communication carrier module VW3A66205 (not the drive s main PCMCIA slot), and requires drive firmware revision 3.2 or later. NOTE: This manual is not intended to be used as a guide for drive operations. It is written to explain connection of the A66SM to the PowerLogic or PNIM network, and to describe the mapping of the drive parameters into registers. For information on drive operation, refer to Instruction Bulletin VD0C06S304B (Altivar 66 User s Manual). Figure 1: Altivar 66 variable frequency drive. A66SM Manual 5

2 Installation Refer to Section 1 of Instruction Bulletin VD0C06S308 for installation instructions for the A66SM communication card in the Altivar 66 drive controller. Please note the following additions/modifications to the Square D installation instructions: For the A66SM communications card to operate correctly, the drive into which it is installed must have revision 3.2 or later firmware. This may be viewed on the Drive Identification menu page, for example ATV66U41N4, CT, V3.2 In the drive s communications setup (Menu 11), set Protocol to Modbus+ and Address to the desired slave address. Set the Timeout to a value appropriate for the system s scan rate. When the drive is under Serial Link Control, this timeout value will determine how long the drive will run without receiving communications from the PNIM or PowerLogic bus master before shutting down. The Peer Cop and Global Data parameters are not used and should be set to NO and zero respectively. When the card is recognized by the drive, the drive s Comm. State menu (menu 12) will reflect the selected address and show a constantly changing token counter. The adapter supports the SY/MAX PNIM and PowerLogic serial protocols at 9600 bits per second, 8 data bits,1 start bit, 1 stop bit, and even parity. The port settings cannot be changed in the field. The A66SM PCMCIA card has an attached cable which terminates in a 15-pin D- Subminiature male plug. LAN Connection to this plug is as shown in Figure 2 on page 8. Connection to this plug may be made using Phoenix Contact part number FLKM-D 15 SUB/B, or by building a cable to make the following connections: A66SM Manual 7

8 15 7 14 6 13 5 12 4 11 3 10 2 9 1 IN- OUT- OUT+ IN+ SHIELD Figure 2: Connection of PowerLogic network to A66SM DB-15 connector. Two-Wire Connection The A66SM may be run on a two wire RS-485 network, with Circuit Monitors, and probably other devices which use PNIM protocol. Two wire RS-485 communication to a PowerLogic network may only be done using the PNIM protocol (PowerLogic protocol is full-duplex). To connect the A66SM to a 2-wire network, its transmit and receive pairs must be electrically connected near the connector (i.e. IN+ to OUT+ and IN- to OUT-). Thus, the (+) wire of the RS-485 network connects to both IN+ and OUT+, and the (-) wire connects to both IN- and OUT-. 8 A66SM Manual

3 Operation The essential command and monitoring parameters of the Altivar 66 drive controller are mapped into registers as described in Table 1, beginning on page 11. The most basic motor control can be accomplished using registers 2021, 2022, and 2032: NOTE: This manual references bits in the standard SY/MAX notation where the least significant bit (lsb) is bit 1 and the most significant bit (msb) is bit 16. Instruction Bulletin VD0C06S309 (Modbus+ PCMCIA manual) uses the notation of the lsb being bit 0 and the msb bit 15. Register 2021 contains a bitmap of discrete drive controls. Bits 2 and 3 of register 2021 put the drive controller in SLC (Serial Link Control) mode when set, and release the drive controller into local control mode when cleared. (NOTE: SLC mode is not available when the drive controller has its PI regulator enabled.) In SLC, the drive receives its operational parameters (speed, direction, etc.) from the A66SM, whereas in local control mode serial communications can only be used to gather data. Bit 6 of Register 2021 starts the motor when set, and stops the motor when cleared. Register 2022 sets the reference frequency (thus, speed) of the drive. Bit 2 of Register 2032, when set, commands the drive to run in the reverse direction. While in SLC mode, the drive controller will stop the motor if it does not receive valid communication from its master within the Communications Timeout interval (programmed through the keypad, in Menu 11). Bit 5 of Register 2021, when set, disables this serial link timeout feature, such that if serial communications are lost, the drive will continue to run. This mode of operation is not recommended for normal use. During loss of control, it is almost always safest for the operation to cease until repairs can be made. A communications timeout fault, or any other resettable fault can be cleared by setting Bit 1 of register 2021. This bit will automatically return to 0 after being set. For further information on register significance, and drive operation refer to Instruction Bulletin VD0C06S309 (Modbus+ PCMCIA manual). The A66SM card has two LED indicators. The green indicator will flash as PNIM or SY/MAX communications packets are received. The red indicator will flash if a packet or A66SM Manual 9

command is in error or otherwise not recognized by the card. If the last message sent to the card has an error, the red light may stay on until a new, good, packet is received. Errors which will light the red LED include: Checksum error, inter-character timeout error, attempt to read or write an unsupported or illegal register, or an illegal SY/MAX opcode. 10 A66SM Manual

Table 1: Register map for the A66SM Address Bit Description 2001 --- High Speed 2002 --- Low Speed 2003 --- Accel 1 2004 --- Decel 1 2005 --- Accel 2 2006 --- Decel 2 2007 --- Slip Compensation 2008 --- IR Compensation 2009 --- Profile 2010 --- Voltage Boost 2011 --- Damping 2012 --- Bandwidth 2013 --- Motor Overload 2021 1 Drive Reset 2 Assignment of logic commands over link (DLI) 3 Assignment of references over link (FLI) 4 Alternate ramps (Ramp 2) 5 Suppression of communication control (NTO) 6 Run/Stop Command 7 Braking by DC injection (DCB) 8 Orient Stop 9 Freewheel Stop 10 Fast Stop 11 Command of voltage reduction 12 Multi-Motors 13 Multi-Parameters 15 External fault command (EFL) 16 Peer Cop Adjustment storage 2022 --- Reference Frequency 2023 2-4, 7-9 Command of LOx / ROx state 2024 --- Command of AO1 Level 2025 --- Current Limit level 2026 --- Motoring torque limit level 2027 --- Regenerating torque limit level 2029 --- Voltage reduction level 2030 --- Command of AO2 level 2031 --- Command of AO3 level A66SM Manual 11

Table 1: Register map for the A66SM (cont d) 2032 1 Command of current limit 2 Run direction 4 Command of torque limit 9 Elapsed timer reset 2041 1 Mode in which all commands are assigned 2 Drive controller ready (RDY or SLC) 3 Fault (FLT) 4 Reset authorized 5 Brake engage relay state 6 Forced local 7 NTO 8 Resettable fault 9 Motor running 10 Actual rotation direction 11 DC injection braking 12 Steady state 13 Motor thermal overload alarm 15 Current limit 16 No line power (NLP) 2042 --- Output frequency 2043 --- Output current 2044 2-9 Display of logic input activation (LI1 - LI8) 10-11 Display of logic output activation (LO1 - LO2) 12-15 Display of relay activation (R1 - R4) 2045 --- Value of analog input (AI1) 2046 --- Motor torque 2047 --- Speed reference 2048 1 Local command mode T/K 2 Logic commands over link (DLI) 3 Reference commands over link (FLI) 4 Dynamic braking 5 Fast stop 6 Power loss, ramp stop 7 Gating state 8 Orient complete 9 Deceleration (DEC) 10 Acceleration (ACC) 11 Multi-motor or 12 Multi-parameter selected 14 Drive controller thermal fault 15 Torque limit 16 Stopping by the keypad 12 A66SM Manual

Table 1: Register map for the A66SM (cont d) 2049 1 Jog 2 Shutdown complete 3 Cycle complete 4 Alternate ramp 5 Auto/Manual 6 Frequency level 1 attained 7 Frequency level 2 attained 8 Current level 1 attained 9 Current level 2 attained 10 Thermal level 1 attained 11 Thermal level 2 attained 12 No ramp follow 13 Run output command 14 Rotation direction 2050 1 Drive faulted, stopped 5 State of adjustment semaphore 6 State of command semaphore 2051 --- Display of fault causing trip 2052 --- Display of present faults 2053 --- Output power 2054 --- Output voltage 2055 --- Line voltage 2056 --- Bus voltage 2057 --- Motor thermal state value 2058 --- Drive controller thermal state value 2059 --- Elapsed time (hours) 2060 --- Elapsed time (minutes) 2061 --- Output speed (rpm) 2062 --- Machine frequency reference number (customer units) 2063 --- Machine frequency (customer units) 2064 --- Value of analog input AI2 2065 --- Value of analog input AI3 2066 --- Value of analog input AI4 2067 --- Value of AO1 2068 --- Value of AO2 2069 --- Value of AO3 2070 --- Speed ramp output 2072 --- Nominal motor voltage range 2075 --- Number of motor or parameter set selected 2076 --- Cycles step number in progress 2077 --- Preset speed number in progress A66SM Manual 13

Table 1: Register map for the A66SM (cont d) 2101 --- Assignment of AI1 2102 --- Assignment of AI2 2103 --- Assignment of AI3 2104 --- Assignment of AI4 2105 --- Assignment of AO1 2106 --- Assignment of AO2 2107 --- Assignment of AO3 2108 --- Assignment of LO1 2109 --- Assignment of LO2 2112 --- Assignment of R1 2113 --- Assignment of R2 2114 --- Assignment of R3 2115 --- Assignment of R4 2116 --- Assignment of LI1 2117 --- Assignment of LI2 2118 --- Assignment of LI3 2119 --- Assignment of LI4 2120 --- Assignment of LI5 2121 --- Assignment of LI6 2122 --- Assignment of LI7 2123 --- Assignment of LI8 2141 --- Indicates the position of marker on 1 of 8 past faults 2142 --- Past fault 1: Drive controller state 2143 --- Past fault 1: Name of fault 2144 --- Past fault 2: Drive controller state 2145 --- Past fault 2: Name of fault 2146 --- Past fault 3: Drive controller state 2147 --- Past fault 3: Name of fault 2148 --- Past fault 4: Drive controller state 2149 --- Past fault 4: Name of fault 2150 --- Past fault 5: Drive controller state 2151 --- Past fault 5: Name of fault 2152 --- Past fault 6: Drive controller state 2153 --- Past fault 6: Name of fault 2154 --- Past fault 7: Drive controller state 2155 --- Past fault 7: Name of fault 2156 --- Past fault 8: Drive controller state 2157 --- Past fault 8: Name of fault 14 A66SM Manual

Table 1: Register map for the A66SM (cont d) 2201 --- Drive controller horsepower (hardware rating) 2202 --- Drive controller horsepower (configured rating) 2203 --- Drive controller voltage range 2204 --- Line frequency recognized 2205 --- Drive controller maximum rated frequency 2206 --- Drive controller nominal current 2207 --- Drive controller maximum current 2212 --- Memory card option 2213 --- Communication carrier option 2214 --- Presence of keypad 2215 --- I/O Extension option card 2217 --- PCMCIA communication card A66SM Manual 15