Vigil 3 Amplifiers. Installation Instructions

Similar documents
BVRD Network. Installation Instructions

Operating Instruction Manual POWERED MIXER. Model MX-401. Toa Electric Co., Ltd. KOBE, JAPAN

Operating Instructions

Operating instruction Manual POWERED MIXER. Model MX-101. Toa Electric Co., Ltd. KOBE, JAPAN

APT20. User Manual.

Product Manual ASL Document Ref.: U doc Issue: 04 complete, approved - Date: 16/08/10 Part Number: M0618_23

Installation Guide. QBox-V6. Standalone/Spare V6 SDI QBox. Standalone/Spare V6 SDI QBox. Part No. A

Operating instructions AS-i SmartLine module AC3200 AC /00 06/2016

Care2. Installation Instructions. Firmware version: MCCNTPNL V 04.02

HCS-3600 / 3602 / 3604 Laboratory Grade & High RFI Immunity Switching Mode Power Supply with Rotary Encoder Control

DUAL MONO POWER AMPLIFIER INSTRUCTIONS FOR USE

TOA ELECTRIC CO., LTD.

MODEL 805 USER MANUAL

Operating instructions. Switching amplifier DN0210 DN / / 2015

AVC 2 AUTOMATIC VOLUME CONTROL USERS MANUAL

Table of Contents Quick Install Guide page Introduction Safety Rack System Precautions ESD Precautions...

QUALITY POWER SOLUTIONS BACKED UP BY REAL-WORLD ENGINEERING EXPERIENCE

Installation instructions Diagnostic electronics for vibration sensors VSE / / 2007

PRE116/126. User Manual.

BASIC PA AMPLIFIER A-1031 A-1061 A-1121 OPERATING INSTRUCTIONS TABLE OF CONTENTS

BS 287 DUAL CHANNEL POWER SUPPLY. User Manual. January 2017 V1.0

Operating and Maintenance Instructions

The Martin Experience. Martin Audio CMX1A Cinema Controller MARTIN AUDIO. All material Martin Audio Ltd. Subject to change without notice.

BS 217 DUAL CHANNEL MASTER STATION USER MANUAL

RT4F-120V/20A-WAC RECTIFIER

T L Audio INDIGO SERIES. User Manual C-2021 VALVE COMPRESSOR. Tony Larking Professional Sales Limited, Letchworth, England.

PS 230 DUAL CHANNEL REMOTE SPEAKER STATION. User Manual. January 2017 V1.0

Laboratory Switch Mode Power Supply Series. Instruction Manual

Voice Alarm System VX-3000 Series

Operating instructions Evaluation system for flow sensors VS / / 2013

AMP20. User Manual.

Operating instructions. Standstill monitor A / / 2011

MAINTENANCE MANUAL. EDACS REDUNDANT POWER SUPPLY SYSTEM 350A1441P1 and P2 POWER MODULE CHASSIS 350A1441P3, P4, AND P5 POWER MODULES TABLE OF CONTENTS

Operating instructions. Speed monitor D / / 2014

SoundwebTM. Installation Guide

Neutrik 20A powercon with 2nd order EMI filter & GDT/VDR protection circuit against Lightning Strike & Local Power Surge Circuit A

LF3-400 Three Phase Frequency Converter, Operation and Maintenance.

ATS-16 HV USER MANUAL. Automatic Transfer Switch 16A / 230Vac V090318

EA014 Whiteboard Speakers. Manual and installation instructions

OPERATOR MANUAL OSD461A/OSD463A AUDIO FIBER OPTIC TRANSMISSION SYSTEM

A120 A W/240W PA Mixer-Amplifier 70V/100V

CM/CS SERIES. Compact 100V amplifiers. Item ref: UK, UK, UK User Manual. CM/CS Series User Manual

MA100 full-range speaker. user manual

BT110. User manual. Register your product and get support at

Voice Alarm System VX-3000 Series

PCM60A 100W MAX P.A. AMPLIFIER.

TABLE OF CONTENTS 1. SAFETY PRECAUTIONS GENERAL DESCRIPTION FEATURES AND FUNCTIONS 4. CONNECTIONS 6. APPLICATIONS...

MXA2080. Stereo Power Amplifier. Owner s Manual

MAINS DISTRIBUTION UNIT MDU14-CO

Document Part Number: Rev. 01 (December 2009) TouchTunes and the TouchTunes logo are trademarks of TouchTunes Interactive Networks.

T L Audio INDIGO SERIES. User Manual PA-2001 VALVE PRE-AMPLIFIER. Tony Larking Professional Sales Limited, Letchworth, England.

USER MANUAL GOLDMUND MIMESIS 27.8 Preamplifier

PS 289 DUAL CHANNEL POWER SUPPLY USER MANUAL

POWER AMPLIFIER INSTRUCTIONS FOR USE

Operating Instructions

NTP-5521/5531/5561 SWITCHING MODE POWER SUPPLY

Line Impedance Stabilization Network (LISN)

Voice Alarm System VX-3000 Series

ME3 Mobile Cabinet Three Phase Frequency Converter, Operation and Maintenence.

Dual Mono Power Amplifier. Owner s Manual ENGLISH

GSM SECURITY AND CONTROL SYSTEM ESIM021

RT4F-48V/50A-WAC RECTIFIER

VAR4. 4x4 DSP Audio Router. Installation Guide. ASL Document Ref.: U doc Issue: 02 complete, approved - Date: 02/12/09 Part Number: M0450_17

Model HM-535 Power Supply Installation and Service Instructions

EN54-16 COMPLIANT HARDWARE BYPASS MICROPHONE PORTS 12 ANALOGUE AUDIO INPUTS 12 GPIO INPUTS & 12 OUTPUTS 12 ANALOGUE AUDIO OUTPUTS

CD 3.1x/II CD PLAYER OWNER S INFORMATION

PS 430 FOUR CHANNEL REMOTE SPEAKER STATION. User Manual. January 2017 V1.0

QUICK START GUIDE. vau4/3. Frequency converter. operating instructions /12

Achat 110 MA active full-range speaker. user manual

MA V 30W Mixer Amplifier Order code: CRAM02 MA V 60W Mixer Amplifier Order code: CRAM03 USER MANUAL

INTRINSICALLY SAFE Ex ia PSU TYPE AC36W

BS 181 SINGLE CHANNEL POWER SUPPLY USER MANUAL

Operating Instructions

RT4F-110V/25A RECTIFIER

MDM 011-Z1 Regen Resistor

RT12-240V/2.4kW Rectifier Specification

Voca safety instructions

Model 2600B-PM V Protection Module with 1 A Clamp. Description / April 2015 *PPA * 1

This 4200-RM Rack Mount Kit is for installation in 4200-CAB series cabinets only.

Configurable Network Paging Console. Product Instructions. Model: X-NPMI

jcmtechnologies GSM-CARD/VGSM-CARD user s manual communications card

RT4B-110V/12A RECTIFIER

APM. User manual & Installation guide. Digital paging microphone.

TABLE OF CONTENTS 1. OVERVIEW... 1

1 Description. 2 Specifications. Product Installation Document. Honeywell 12 Clintonville Road Northford, CT

IDEAL INDUSTRIES INC. TECHNICAL MANUAL MODEL:

HPA4202 1/5. 2-Channel High Power Multi-Impedance Amplifier. General Description. Features. Applications. AtlasIED.com. HPA4202 Front.

VM SERIES Rackmount 100V mixer-amplifiers

T-60FP/T-120FP Mixer Amplifier

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODELS:

Power Supplies. Chapter The McGraw-Hill Companies, Inc. All rights reserved. Mike Meyers CompTIA A+ Guide to Managing and Troubleshooting PCs

Operating instructions Diagnostic electronics for vibration sensors VSE002 / VXE002 / VXE003 VYE001 / VYE002 / VYE003 / VYE /01 05/2015

V400. Amplifier Mainframe. Installation Guide. ASL Document Ref.: U doc Issue: 02 complete, approved - Date: 30/11/09 Part Number: M0398_63

THIS PAGE LEFT BLANK

Always there to help you. Register your product and get support at BT3500. Question? Contact Philips.

Original operating instructions Safety relay with relay outputs G1501S / / 2016

Installation Manual for D1800 Series High Power PoE Midspan Power Supply

Always there to help you Register your product and get support at BT6000 Question? BT6050 Contact BT6060 Philips User manual

Model 7705 Control Module

Model VT120 Fast Timing Preamplifier Operating and Service Manual

Transcription:

Manual name: Vigil 3 Amplifier Installation Manual Issue: 1 ECR: N/A Date of issue: Dec 2016

Dec 2016 Baldwin Boxall Communications Limited Wealden Industrial Estate Farningham Road, Jarvis Brook Crowborough East Sussex TN6 2JR UK Telephone: +44 (0)1892 664422 Facsimile: +44 (0)1892 663146 Email: mail@baldwinboxall.co.uk Website: http://www.baldwinboxall.co.uk This equipment has been designed and manufactured to conform to the following EC Standards: EMC: EN55103-1 Environment Classification: E1, EMC: EN55103-2 Environment Classification: E5, Safety: EN60065 Failure to use the equipment in the manner described in the product literature will invalidate the conformity. A Declaration of Conformity statement to the above standards and a list of auxiliary equipment used for compliance verification is available on request. ii Vigil 3 Amplifier Installation Manual issue 1

Amendment Record v Proprietary Notice v Safety Information vi Comments vi Introduction Vigil 3 Amplifier Description 1 Vigil 3 Amplifier Specifications 3 Installation Examples Example 1: A-B Dual Circuit 6 Example 2: Paralleled Outputs for Higher Power 7 Basic Fault Finding OK / Fault LED flashing or not illuminated 9 Disassembly Procedures 10 Maintenance Maintenance Requirements of BS5839-8 13 Vigil 3 Amplifiers Routine Maintenance 13 Vigil 3 Amplifier Installation Manual issue 1 iii

iv Vigil 3 Amplifier Installation Manual issue 1

AMENDMENT RECORD Change Note Number Nature of Amendment Date of Amendment DP347 Initial release: Issue 1 Dec 2016 PROPRIETARY NOTICE All data and information contained within this manual is of a proprietary nature with the exclusive title to the same held by Baldwin Boxall Communications Limited. The possession of this manual and the use of the information is, therefore, restricted only to those persons duly authorised by Baldwin Boxall Communications Limited. Do not reproduce, transcribe, store in a retrieval system or translate into any language, any part of this manual without the prior permission of Baldwin Boxall Communications Limited. In the interest of continual product development, Baldwin Boxall Communications Limited reserves the right to make changes to product specification without notice or liability. Use of Baldwin Boxall Communications Limited products as critical components in life support systems is not authorised except with express written approval from Baldwin Boxall Communications Limited. Vigil 3 Amplifier Installation Manual issue 1 v

SAFETY INFORMATION Personnel who install, maintain or repair this equipment must read the safety information below before starting work. Voltages in excess of 30 Volts RMS or 50 Volts DC are considered Hazardous and in certain circumstances can be lethal. If Functional Testing, Maintenance, or Repair is to be completed with the Mains Power (and/or battery backup) connected then this should only be undertaken by personnel who are fully aware of the danger involved and who have taken adequate precautions and training. This Manual contains Warnings, Cautions and Notes. Warnings describe potential threats to health or life, e.g.! WARNING Before attempting to remove this component, ensure the Mains Power Supply and Battery Backup have been disconnected. Cautions describe potential threats to the equipment, e.g. CAUTION Notice must be taken of all cautions. If a Caution is ignored the equipment may be damaged. CAUTION: ELECTRO-STATIC SENSITIVE DEVICES Observe the relevant precautions for the protection of Electrostatic Sensitive Devices when handling this equipment. Notes are statements that are useful to the user in the context of a particular section of the manual, e.g. NOTE: Do not speak into the microphone until the "Speak Now" LED is illuminated. COMMENTS Comments regarding the content of this manual are welcome and should be addressed to mail@baldwinboxall.co.uk. vi Vigil 3 Amplifier Installation Manual issue 1

Vigil 3 Amplifier 1 Introduction 1.1 VIGIL 3 AMPLIFIER DESCRIPTION The Vigil 3 Amplifier range consists of modules containing 2 or 4 amplifier blocks. The following Vigil 3 amplifier modules are available; BV75D - 2 x 75W Amplifier Blocks BV150D -2 x 150W Amplifier Blocks BV300D - 2 x 300W Amplifier Blocks BV75Q - 4 x 75W Amplifier Blocks BV150Q - 4 x 150W Amplifier Blocks Vigil 3 Amplifiers contain a built in mains PSU and when combined with a BVMBC Battery Charger Module form a complete EN54-4 compliant Battery Backed power supply system. The audio input for each amplifier is presented on two separate RJ45 connectors. Each amplifiers output is presented on a single 2-way plug/cage clamp termination connectors providing 100V output. Vigil 3 Amplifier Installation Manual issue 1 1

Vigil 3 Amplifier The Amplifier Module Mains Input is presented on a standard IEC connection and the 24V DC input (battery connection) is presented on a two 2-way plug/cage clamp termination. In addition there is a single RJ45 AUX Output for connection to the BVMBC battery charger module. The power output stage of the amplifier is protected against overload conditions (i.e. short circuits or abnormal loads). Should an amplifier be subjected to an abnormal load the input to the relevant power amplifier is attenuated to a safe level. The amplifier output voltages are also sensed and should they exceed 100V the relevant input signal will be attenuated ensuring safe operation without creating unnecessary distortion. Over temperature protection is provided using sensors attached to the module heat sink. Should the temperature exceed 70C an Over Temperature fault is indicated and if it exceeds 75C the input signal to the relevant amplifier will be attenuated to a safe level. If the system is under surveillance it will cause the surveillance detector to indicate a fault condition due to the gain reduction. Each amplifier block has status LED s on the front panel consisting of an OK/FAULT LED and a 10%/100% LED. The OK/FAULT LED indicates the following; Steady Green - OK Flashing Green - PSU Fault, no 24V or mains present Yellow - Overload or Over Temperature Fault The 10%/100% LED indicates the following; Off - No signal output Green - 10V signal output Yellow - 100V signal output 2 Vigil 3 Amplifier Installation Manual issue 1

Vigil 3 Amplifier 1.2 VIGIL 3 AMPLIFIER SPECIFICATIONS AMPLIFIERS 1KHz rated O/P power, <0.2% THD Output regulation Output voltage obtainable Frequency response (-3dB) Input sensitivity and impedance Input common mode rejection ratio O/P noise reference to rated O/P Cross talk between amps at 1kHz Supply voltage (batteries) Standby current (batteries) Table 1.1 Vigil 3 Amplifier Specifications BV300D 2 x 300W 300W @ 33.3 Ohms Better than 0.5dB Better than 85dB(A) BV150D 2 x 150W BV150Q 4 x 150W 150W @ 66.6 Ohms Better than 0.3dB 100V only 35Hz to 20kHz BV75D 2 x 75W 0dBm @ 10K Ohms Balanced BV75Q 4 x 75W 75W @ 132 Ohms Better than 0.2dB (50Hz-20kHz) better than 40dB (typically 60dB) Better than 80dB(A) Better than 70dB 22-28V DC 50mA per amplifier Rated output power 14A / Amp 7.5A / Amp 3.75A / Amp Output stage protection Thermal Load Action Fuse Protection Output stage above 90 C Excessive output stage current Reduces input to safe level using low distortion VCA AC supply (5 x 20mm) 2 x 2A(T) 1 x 2A(T) 2 x 2A(T) 1 x 2A(T) 2 x 2A(T) Battery (automotive blade) 2 x 20A 1 x 20A 2 x 20A 1 x 20A 2 x 20A Terminations Speaker Line O/P Balanced line inputs DC supply (batteries) Mains supply input Dimensions 2 x cage clamp 4 x 2 cage clamp RJ45 connections 2 pin rising clamp 2 x cage clamp IEC 6A filtered connector 142 mm W x 75 mm H x 311 mm D 4 x 2 cage clamp Weight 3.1 kg 2.3kg 3.1kg 2.3kg 3.1kg Mains Supply Standby Power Consumption (Mains) 230 V +10%/-15% 50/60Hz 16W 8W 16W 8W 16W AUX DC O/P @ 30V 5A 2.5A 5A 2.5A 5A Max Power Consumption 700W 350W 700W 175W 350W Vigil 3 Amplifier Installation Manual issue 1 3

Vigil 3 Amplifier 4 Vigil 3 Amplifier Installation Manual issue 1

2 Installation Examples The Vigil 3 Amplifiers have been designed for quick and simple connection and configuration. The individual amplifier blocks can either be used as independent amplifiers, can be one of two amplifiers wired as an A-B Dual Circuit using a single input signal, or the 300W amplifiers can be paralleled with other 300W Vigil 3 Amplifiers to enable higher power outputs (up to a maximum of 4 Vigil 3 300W amplifiers giving a total of 1200W). NOTE: Where possible when A-B circuits are used it is recommended that A and B circuits are connected to amplifiers in serperate modules. This is due to power supplies, mains connections and battery connections being shared by amplifiers inside a module. NOTE: Where possible when reserve amplifiers are used it is recommended that reserve amplifiers should be located in a different amplifier module to the primary amplifier. This is due to power supplies, mains connections and battery connections being shared by amplifiers inside a module. The amplifier blocks have two paralleled input connectors to enable simple interconnection using standard RJ45 patch leads. The 100V Line output connectors are cage clamp type as this type of connector is more reliable than screw terminals. Vigil 3 Amplifier Installation Manual issue 1 5

In order to use the Vigil 3 amplifiers with a BVMBC battery charger module the AUX output connection of up to 5 amplifier modules must be connected to the BVMBC. For more information please see the BVMBC installation manual. 2.1 EXAMPLE 1: A-B DUAL CIRCUIT Figure 2.1 Both Amplifiers use the same Input Signal 6 Vigil 3 Amplifier Installation Manual issue 1

2.2 EXAMPLE 2: PARALLELED OUTPUTS FOR HIGHER POWER Figure 2.2 Connection Details & Settings for Paralleled Amplifiers NOTE: A maximum of 4 300W amplifier modules can be paralleled togetther (i.e. 2 x BV300D). Only parallel 300W modules. NOTE: It is not recommended to use paralleled amplifiers in Voice Alarm Systems, consider lower power A-B circuits instead. Vigil 3 Amplifier Installation Manual issue 1 7

8 Vigil 3 Amplifier Installation Manual issue 1

3 Basic Fault Finding The Vigil 3 Amplifiers front panels provide indicators to show the current status of the unit. The following sections provide basic Fault Finding information should these indicators show a fault condition. 3.1 OK / FAULT LED FLASHING OR NOT ILLUMINATED The OK/FAULT LED should be permanently illuminated green to show the mains and 24V DC supplies are present. Vigil 3 Amplifier Installation Manual issue 1 9

Should the OK/FAULT not be permanently illuminated green please refer to Table 3.1 for fault finding information Table 3.1 Fault Finding OK/FAULT LED Status Fault Check Off No Power Present (24V or Mains) Battery Connection Battery Voltage Battery Fuses Mains Connection Mains Fuses / Circuit Breakers Flashing 24V or Mains Supply Failed Remove 24V supply if LED extinguishes then fault is with mains supply. Check mains supply as above. Remove Mains Supply if LED extinguishes then fault is with 24V supply. Check battery connections as above. If both Mains Supply and 24V supply are present at the amplifier module then it has failed and must be returned for service. Yellow Overload or Overtemperature Fault Disconnect speaker lines, if LED returns to Green then either the speaker lines are overloaded or shorted Disconnect speaker lines, if LED remains yellow then an overtemperature fault has occured. Allow amplifier module to cool and check cooling fans. 3.2 DISASSEMBLY PROCEDURES There are no Disassembly Procedures for this unit.! WARNING The Vigil 3 Amplifiers output stages contain Hot Parts, High Voltages, and operate at High Frequencies. Do not attempt to disassemble these units or operate them without the covers in place. 10 Vigil 3 Amplifier Installation Manual issue 1

C AUTI ON There are no user replaceable fuses inside the Vigil 3 amplifiers. Failed units should be returned to Baldwin Boxall for repair or replacement. Vigil 3 Amplifier Installation Manual issue 1 11

12 Vigil 3 Amplifier Installation Manual issue 1

4 Maintenance 4.1 MAINTENANCE REQUIREMENTS OF BS5839-8 When a Vigil 3 Amplifiers is installed in a Voice Alarm System then the system must be maintained according to the requirements of BS5839-8. 4.2 VIGIL 3 AMPLIFIERS ROUTINE MAINTENANCE The Vigil 3 Amplifiers amplifier module requires a minimum of routine maintenance. If the unit is operated in a particularly dusty environment, it may be necessary to occasionally remove accumulated dust from the external heatsink using a vacuum cleaner or similar. Vigil 3 Amplifier Installation Manual issue 1 13