I/O SIGNAL CONDITIONER

Similar documents
FA-2448 SIX POSITION Filter Wheel

OPERATING AND SERVICE MANUAL. Universal Interface Device 47

MODBUS MANUAL For the AccUView UV Transmission Monitor

OPERATING AND SERVICE MANUAL. Universal Interface Device 47

User's Guide. Programmable DC Power Supply 200 Watt (40 Volts / 5 Amps) Model Introduction

Global Water Instrumentation, Inc.

USER MANUAL. WBV412U01 AC voltage transducer

TC1880 Series. 4/5/6/8 Channel RS-232 FIBER OPTIC MICRO MUX User's Manual

INTMOD485-LH Protocol Converter

CTI 2551-A 8-CHANNEL ISOLATED THERMOCOUPLE INPUT MODULE INSTALLATION AND OPERATION GUIDE. Version 1.3 CTI Part # * *

INSTALLATION MANUAL. LC 200 Electronic Overload Guard. Software versione PW0501 R 0.3

USER MANUAL. WBI412F41 AC current transducer

User's Guide. Extech AM A AC Analog Clamp Meter

16/24 Port 10/100 Auto-Sensing Dual Speed Ethernet Switch

Enhanced Mini-Chansim Model VCS-232

SA SERIES Arlingate Lane, Columbus, Ohio (614)

Model CR103J. DC Current and Voltage Calibrator/Standard ±0.01µA to ± mA ±0.1µV to ± V. Operating Manual

Eco Sensors OZONE CONTROLLER Model OS-6 Instructions for Use. General and New Features

EPS Power Supply

USER MANUAL. WBI414F21 AC current transducer

DT1102 V (PS) Fully Configurable Galvanic Isolator. Operating Instructions

POWER SERIES Plus. 3 in 1 AC Voltage. Digital Switchboard Meter. User s Manual IM2493VVV-2

3 Input Multiplexer Operation Manual

NOTE: The F2 button and the 4 LED annunciators do not function on the LD-ACF-I. To use these features, ask about the LD-ACF-R4/R4A.

Cantata m100 Amplifier

OPERATING AND SERVICE MANUAL. Universal Interface Device 45

MD9 MULTIDROP INTERFACE INSTRUCTION MANUAL

Eco Sensors OZONE CONTROLLER Model OS-6 Instructions for Use. General and New Features

XBDM. 1015LV, 1020LV, 1030LV, 1020HV Models USER & INSTALLATION MANUAL BYPASS DISTRIBUTION MODULE

OPERATOR S MANUAL 9000U ISOLATOR

Kramer Electronics, Ltd. USER MANUAL. Models: RC-2C, Wall Plate / RS-232 / IR Controller RC-2, Wall Plate / RS-232 Controller

IT6800 series Frame Format

User's Guide. Phase Sequence and Motor Rotation Tester Model

ES-600 Ozone Controller Operation Manual

TH2683 Insulation Resistance Meter. User s Mannual

CTI 2552-A 8-CHANNEL ISOLATED RTD INPUT MODULE INSTALLATION AND OPERATION GUIDE. Ver. 1.2 CTI Part #

Omnitron Systems Technology, Inc. 1. iconverter. 19-Module Managed Power Chassis User s Manual

Remote Refrigeration Control

DCM Digital Control Modules

DCS-E 1kW Series, DLM-E 3kW & 4kW Power Supplies

CL600 SIMPLE LOGGER RMS CLAMP-ON MODULE E N G L I S H. User Manual

User Manual MIOe port CAN-bus PCIE/MIOe Module with Isolation Protection

7032 Digital-Analog Multimeter

User's Guide. MiniTec TM Series Model MN25 MultiMeter

iconverter 2-Module Power Chassis

BNI IOL A027 BNI IOL A027

CTI 2550 EIGHT CHANNEL ISOLATED ANALOG INPUT MODULE INSTALLATION AND OPERATION GUIDE. Version 2.0 CTI Part # IOG $25

Installation manual Digital Energy USB / RS232 / Relay Interface Card for use with GE Digital Energy VH Series UPS VA

CEM M-RS485 INSTRUCTION MANUAL (M014B A)

AC/DC Current Probe Model SL201

Automated Tuner System Power Distribution Hub

Intech Micro 2300-A8VI analogue input station MODBUS RTU slave application supplementary manual.

MYRIAD LC1 LEVEL CONTROLLER INSTRUCTION MANUAL

MYRIAD QLC 4-CHANNEL MONITOR/CONTROLLER INSTRUCTION MANUAL

R & D SPECIALTIES SERIES 100 RO CONTROLLER USERS MANUAL. 2004, by R & D Specialties, Inc. All Rights Reserved.

PMDX-105. I/O Option Riser Board User s Manual. Document Revision: 1.1 Date: 7 September 2004 PCB Revision: PCB-443A

AC/DC Current Probe Model SL206 USER MANUAL

User Manual PCM Port CAN-Bus Mini PCIe Module with Isolation Protection

POWER SERIES Plus Watt-VAR / Watt-Power Factor Digital Switchboard Meter User s Manual IM2492WVPF-1

ControlKeeper 4. General Information. Connecting Relay Loads. Installation Sheet. Getting Started. Power Supply Wiring. Mounting the Cabinet

VADDIO /CANON BU-SERIES PTZ CAMERAS

PCM PC/ bit Digital I/O Module. User Manual

SUPPLEMENT TO THE MDC-360C MANUAL MDC-361C. Film Deposition Controller. IPN Rev. C

SHPFI Smart Frequency to Current Converter & Pulse Scaler Installation and Operating Instructions

I/O Expansion Box Installation & Operator s Instruction Manual

COBALT C INSTALLATION GUIDE RFID CONTROLLER ESCORT MEMORY SYSTEMS. High Frequency Passive Radio Frequency Identification Controller

4170 POS System Installation Guide

Operation Manual CX10 1/8 DIN Microcomputer Based Conductivity/Resistivity Controller

DC 100 A Current Probe

The Martin Experience. Martin Audio CMX1A Cinema Controller MARTIN AUDIO. All material Martin Audio Ltd. Subject to change without notice.

OZONE SWITCH Model OS-6. OS-6 Features

DM-918 OPERATIONS MANUAL AUTORANGING MULTIMETER

WAXPENCIL PRO Owner & Operator s Manual

RS-232 to RS-422/485 Converter with 3KV Isolation Protection

USER S GUIDE Programmable DC Power Supply Model IT6322

MODEL ELECTRONIC COMPASS

INSTRUCTION MANUAL CM-60. Monitor. Ultra Stereo Labs, Inc. 181 Bonetti Drive San Luis Obispo, CA Telephone

SCC-AO10 Isolated Analog Output Module

5/8-Port Industrial Fast Ethernet Switch ISW-500/ISW-800. User's Manual

MAINTENANCE MANUAL. EDACS REDUNDANT POWER SUPPLY SYSTEM 350A1441P1 and P2 POWER MODULE CHASSIS 350A1441P3, P4, AND P5 POWER MODULES TABLE OF CONTENTS

850A/B Contact Chatter Detector User Manual

Contents INTRODUCTION...1 CARD SETUP...2 INSTALLATION TECHNICAL DESCRIPTION SPECIFICATIONS... 14

MIC-3001/8. 3U/4U CompactPCI. Enclosure for Rackmounting

AB300-Series Automated Filter Wheels

DFI 9000 PORTABLE DIGITAL INDICATOR USER S GUIDE

NMEA2000 DC MONITOR Part Numbers: 3410 USER MANUAL

CMSA-100 Manual. Cinema Media Server Automation

Miniature Overhead Stirrer

Warner Instruments 1125 Dixwell Avenue, Hamden, CT (800) / (203) (203) fax

MODEL 245 / 345 High Range

HI ma Simulator

The Analyst. RS422/RS232 Tester. (Standard Model) User Manual

INSTRUCTION MANUAL. Instruction Manual. Analog Multi-Tube Vortexer Digital Multi-Tube Vortexer

MT8050iE series. Installation Instruction (1) (2)

Operation Manual. Concorde 600 Power Supply. *This instrument is intended for laboratory use only.

ACLD Channel Opto-isolated Digital Input Board

USER MANUAL. MODELS 1205 and 1205/34. Synchronous V.35 Modem Eliminators

ADAM Fiber Optic to RS-232/422/485 Converter

OPERATING MANUAL LOW-VOLTAGE DISCONNECT PANELS LVD400 & LVD600 SERIES

Industrial Ethernet Ethernet to Serial Gateways Ethernet to Serial Converters for Modbus, Red lion and other protocols

Transcription:

Technical Data Sheet No. TD9809M Rev. F Date of Issue: December 9, 2009 OPERATING MANUAL I/O SIGNAL CONDITIONER CAUTION: THIS PRODUCT DOES NOT PROVIDE GALVANIC ISOLATION. DO NOT ATTEMPT USE OF THIS PRODUCT WHERE COMMON MODE VOLTAGES EXIST BETWEEN INPUTS, OUTPUTS, POWER SUPPLY, OR THE SERIAL COMMUNICATIONS TERMINALS.

TABLE OF CONTENTS (a) (b) (c) (d) (e) (f) (g) (h) (i) (j) (k) UNPACKING THE I/O SIGNAL CONDITIONER... a. Inspect Package for External Damage... a.2 Unpack the Signal Conditioner... a. Returning Merchandise for Repair... DESCRIPTION... 2 FEATURES... 2 SPECIFICATIONS... 2 d. General Attributes... 2 d.2 CE Compliance... ELECTRICAL CONNECTIONS... e. Connector Pin Assignments... e.2 Jumper Assignments... 4 PROGRAMMING... 4 CALIBRATION PROCEDURES... g. Equipment Required for Calibration... g.2 Calibration... SELECTING THE MODE OF OPERATION... COMMANDS... TROUBLESHOOTING GUIDE... 9 TECHNICAL ASSISTANCE... 9 APPENDIX APPENDIX 2 APPENDIX APPENDIX 4 COMPONENT DIAGRAM DIMENSIONS CONNECTION DIAGRAM FOR RS22 and RS48 WARRANTY

(a) UNPACKING THE I/O SIGNAL CONDITIONER a. Inspect Package for External Damage Your I/O Signal Conditioner was carefully packed in a sturdy cardboard carton, with anti-static cushioning materials to withstand shipping shock. Upon receipt, inspect the package for possible external damage. In case of external damage to the package contact the shipping company immediately. a.2 Unpack the I/O Signal Conditioner Open the carton carefully from the top and inspect for any sign of concealed shipping damage. In addition to contacting the shipping carrier please forward a copy of any damage report to your distributor or Aalborg directly. When unpacking the instrument please make sure that you have all the items indicated on the Packing List. Please report any shortages promptly. a. Returning Merchandise for Repair Please contact the customer service representative of your distributor or Aalborg if you purchased your I/O directly, and request a Return Authorization Number (RAN). Equipment returned without an RAN will not be accepted. Aalborg reserves the right to charge a fee to the customer for equipment returned under warranty claims if the instruments are tested to be free from warrantied defects. Shipping charges are borne by the customer. Items returned "collect" will not be accepted! It is mandatory that any equipment returned for servicing be purged and neutralized of any dangerous contents including but not limited to toxic, bacterially infectious, corrosive or radioactive substances. No work shall be performed on a returned product unless the customer submits a fully executed, signed SAFETY CERTIFICATE. Please request form from the Service Manager.

(b) DESCRIPTION This Signal Conditioner allows analog voltage levels to be set and read via its RS-22 serial port. Commands are provided to perform various functions: an analog output, read an analog input, verify the communications link, programming, and enter calibration mode. (c) FEATURES The I/O is capable of operating in a voltage output mode or a current output mode. When operating in the voltage mode the analog input and output range is 0.00 to.00 volts. In the current mode the analog input and output range is 4.00 to 20.0 milliamps. See Selecting the Operating Mode. (d) SPECIFICATIONS d. General Attributes INPUT AND OUTPUT ANALOG RANGE: 0 - Vdc or 4-20 ma, jumpers selectable. INPUT OVERVOLTAGE/OVERCORRECT PROTECTION: Vdc, 0 ma. MINIMUM OUTPUT VOLTAGE COMPLIANCE IN 4-20 ma MODE: 8 Vdc. MAXIMUM INPUT VOLTAGE DROP IN 4-20 ma MODE: Vdc. POWER SUPPLY REQUIREMENTS: 0 to 0 Vdc, less than 0.7 watts (OPTIONAL). OPERATING TEMPERATURE RANGE: 0 F C to 70 F C. ALTITUDE: to 0,000 feet. DIGITAL VOLTAGE STANDARD: RS-22 or RS-48 (not galvanically isolated). COMMUNICATIONS PARAMETERS: 8 bits, one stop bit no parity (N,8,). RS-22 COMMON MODE CAPABILITY: +0 volts. RESOLUTION: 0 bits (0.%). DATA FORMAT: ASCII. DATA TRANSFER RATE: 00 baud to 900 baud. MODULE CONNECTION METHOD: Pinch Type terminals. 2

d.2 CE Compliance Any model I/O Signal Conditioner bearing a CE marking on it, is in compliance with the below stated test standards currently accepted. EMC Compliance with 89//EEC as amended; Emission Standard: EN 0:99, Group, Class B Immunity Standard: EN 082 :992 Environmental (per IEC 4): Installation Level II; Pollution Degree II (e) ELECTRICAL CONNECTIONS e. Connector Pin Assignments All connections are made at connector J. This is a pinch type connector. Insert a small flat blade screwdriver into the slot along the top of J and press down. This will cause the pinch clamp to open allowing the stripped wire to be inserted. Remove the screwdriver and the connection is made. Pin - Analog input from sensor IN+ Pin 2 - Analog input from sensor IN- Pin - Analog output to sensor OUT+ Pin 4 - Analog output to sensor OUT- Pin - Data output from module TX (-) Pin - Data input to module RX (+) Pin 7 - Power supply input to module 0VDC - 0VDC Pin 8 - Power supply return (GND) CAUTION: Exceeding the following voltages will cause device failure and/or hazardous conditions to exist. Terminal Number Maximum Voltage VDC) Mode 0 voltage input current input (see note) (see note) voltage output current output (see note) RS-22 RS-48 RS-22 RS-48 7 all Note: The applicable terminals are utilized as outputs. Do not apply any external voltage or current sources to these terminals.

CAUTION: Make sure power is OFF when connecting or disconnecting any cables in the system. The power input is protected by a A re-settable fuse. If a shorting condition or polarity reversal occurs, the fuse will cut power to the flow transducer circuit. Disconnect the power to the unit, remove the faulty condition, and reconnect the power. The fuse will reset once the faulty condition has been removed. e.2 Jumper Assignments JP - Program mode jumper Pins and 2 select Run mode Pins 2 and select Program mode JP - Input mode jumper Pins and 2 select 0 - VDC mode (factory default) Pins 2 and three select 4-20 ma mode JP2, JP4, JP - Output mode jumpers Pins and 2 select 0 - VDC mode (factory default) Pins 2 and select 4-20mA mode (f) CAUTION: Improper setting of jumpers may result in incorrect operation of the unit and could cause damage to the connected equipment. PROGRAMMING Programming the module allows the user to set the communications baud rate, module address and, whether to use error checking. Note that the address is included only for compatibility with the RS-48 version of this unit. Note: All I/O conditioners are programmed on the factory by default settings: address, baud rate 900, and error checking OFF. Connect a dumb terminal or PC running a communications program, such as Procomm, to the unit. RS22 APPLICATION: Connect the unit TX line to the terminal RX line, connect the unit RX line to the terminal TX line. Connect the I/O GND (pin 8) to SG Terminal. 4

RS48 APPLICATION: Make sure RS48 Terminal Equipment (RS-48 to RS22 Converter) is configured for bidirectional Multi drops Two-Wire Half-Duplex operation (TX+ is connected to RX+ and TX- is connected to RX-). Connect the unit TX(-) line (pin ) to the terminal TX- line, connect the unit RX+ line (pin ) to the terminal TX+ line. Connect the I/O GND (pin 8) to terminal GND (if applicable). To program the module remove power from the unit and install the shorting plug on jumper JP between pins 2 and. Apply power to the unit and follow the on screen instructions. When programming is completed turn the unit off, place the shorting plug on jumper JP on pins and 2 to return the module to run mode, the new settings will take affect when the unit is powered on. The initial power on defaults are 900 baud, 8 data bits, stop bit, no parity, error checking off, address 0. (g) CALIBRATION PROCEDURE g. Equipment Required for Calibration You will need a -/2 digit DMM set to the selected analog output range (see Selecting Operating Mode), a power supply and, a dumb terminal or PC running a communications program, such as Procomm. Note: All I/O conditioners are calibrated on the factory for 0 - V mode. Usually it is not necessary to calibrate unit, unless 4 to 20 ma mode is required. g.2 Calibration Connect the dumb terminal or PC. RS22 APPLICATION: Connect the unit TX line to the terminal RX line, connect the unit RX line to the terminal TX line. Connect the I/O GND (pin 8) to the SG line terminal. RS48 APPLICATION: Make sure RS48 Terminal Equipment (RS-48 to RS22 Converter) is configured for bidirectional Multi drops Two-Wire Half-Duplex operation (TX+ is connected to RX+ and TX- is connected to RX-). Connect the unit TX(-) line (pin ) to the terminal TX- line, connect the unit RX+ line (pin ) to the terminal TX+ line. Connect the I/O GND (pin 8) to terminal GND (if applicable). Apply power to the I/O, issue the calibrate command and follow the on screen instructions. See Host C command for format.

(h) SELECTING THE MODE OF OPERATION Before operating in the desired mode the I/O has to be calibrated in the same mode. To set the unit to operate in 0 - V mode install shorting plugs between pins and 2 on JP2, JP, JP4 and, JP. If 4-20mA current mode is desired install the shorting plugs between pins 2 and on JP2, JP, JP4 and, JP. See Jumper Definitions for more detail. (i) COMMANDS The following is a list of the valid commands, command format and, unit response. Host Command format: Where: X X X X crc CR > address command X X X X crc CR > message start character Address unit address is any single printable ASCII command character one of the commands from below optional four ASCII characters, used by the unit to set the analog output optional error checking characters, the crc is composed of two ASCII characters ASCII carriage return character There are no spaces in the transmitted command, spaces are inserted here only to make the command easier to read. If a crc is not used it is not sent in the command line. Commands sent by the host are preceded with a start character symbol, >. All commands are terminated with a CR. If data bytes are not required by the command they are not included in the command line. I/O Module Response format: # X X X X X crc CR Where: # message start character command one of the commands listed below X X X X X up to five ASCII characters, used to report the analog input of the unit back to the host crc optional error checking characters, the crc is composed of two ASCII characters CR ASCII carriage return character There are no spaces in the transmitted response, spaces are inserted here only to

make the response easier to read. If a crc is not required it is not sent in the response line. Responses sent by the I/O Module are preceded with a start character symbol, #. All responses are terminated with a CR. Only the number of data bytes required by the response are sent. Leading zeroes are stripped. Host S Command: S or s - This command queries the I/O Module for its communication status. If the communications line is intact the I/O Module responds to the host with an OK. An example of a valid command to a unit with address M: > M S crc CR > M s crc CR The reply format is: #OK crc CR If the command is not recognized, the I/O Module responds with Bad Command. An example of an invalid command: > M x crc CR The reply format is: #Bad Command crc CR If the command is not received no response is sent. Host T Command: T or t - This command tells the I/O Module to transmit its current reading. Up to five ASCII characters are sent by the I/O Module. The returned data is in millivolts if the module is operating in a 0 - V mode. If the module is operating in a 4-20mA mode the data is in microamps. An example of a valid command to a unit with address : > T crc CR > t crc CR The reply format is: #000 crc CR which corresponds to 000 mv or #900 crc CR which corresponds to 900uA If the command is not recognized Bad Command is returned. An example of an invalid command to a unit with address : > x crc CR The reply format is: #Bad Command crc CR If the command is not received no response is sent. The module returns the analog input data if the command was received and understood. 7

Host R Command: R or r - This command tells the I/O Module to receive a new set point. Four characters must be sent and one of these characters is always a decimal point. If the set point does not fill all four characters trailing zeroes are added. A crc is added if error checking is enabled, otherwise it is not sent. If the command is not recognized Bad Command is returned. An example of a valid command to a unit with address >: > > R.00 crc CR > > r.00 crc CR An example of an invalid command to a unit with address r: > r W.00 crc CR The reply format is: #Bad Command crc CR If the command is not received no response is sent. The module sends OK if the command was received and understood. The reply format is: #OK crc CR Host C Command: C or c - This command tells the I/O Module to enter calibration mode. Calibration instructions are sent to the terminal display. See Calibrating the I/O Module for calibration procedure. If the command is received and understood the unit enters calibration mode. An example of a valid command to a unit with address @: > @ C crc CR > @ c crc CR If the command is not recognized Bad Command is returned. An example of an invalid command to a unit with address @: > @ q crc CR The reply format is: #Bad Command crc CR Host G Command: G or g - This command tells the I/O Module to accept a global command. This is included for compatibility with the RS-48 version of this unit. The syntax is the same as the R command except the address is 0 and no response is sent by the module. An example of a valid command is: > 0 G crc CR > 0 g c crc CR 8

(j) TROUBLE SHOOTING Your I/O Signal Conditioner was thoroughly checked at numerous quality control points during and after manufacturing and assembly operations. It was calibrated in accordance to conditions for a given. It was carefully packed to prevent damage during shipment. Should you feel that the instrument is not functioning properly please check for the following common conditions first: Are all cables connected correctly? Is the power supply correctly selected according to requirements? When several meters are used a power supply with appropriate current rating should be selected. Were the connector pinouts matched properly? When interchanging with other manufacturers' equipment, cables and connectors must be carefully wired for correct. For best results it is recommended that instruments are returned to the factory for servicing. See section a. for return procedures. CAUTION: Use of the I/O Signal Conditioner in a manner other than that specified in this manual or in writing from Aalborg, may impair the protection provided by the equipment. (k) TECHNICAL ASSISTANCE Aalborg Instruments will provide technical assistance over the phone to qualified repair personnel. Please call our Technical Assistance at 84-770-000. Please have your Serial Number and Model Number ready when you call. 9

APPENDIX Components Diagram NOTE: Aalborg7 reserves the right to change designs and dimensions at its sole discretion at any time without notice. For certified dimensions please contact Aalborg7. 0

APPENDIX 2 Dimensions.70 [44.] Ø0.87 [Ø4.7] 4. [0.8].000 [7.2].0 [2.2]. [29.2] DIMENSIONS: INCH [mm] I/O Signal Conditioner NOTE: Aalborg7 reserves the right to change designs and dimensions at its sole discretion at any time without notice. For certified dimensions please contact Aalborg7.

APPENDIX SIGNAL CONDITIONER SIGNAL CONDITIONER COMMON +(0-0) VDC RX(+) TX(-) OUT- OUT+ IN- IN+ 9 8 7 4 2 4 8 7 2 COMMON +(0-0) VDC RX(+) TX(-) OUT- OUT+ IN- IN+ 8 7 4 2 8 7 4 2 4 0 2 9 GFM GFC HOST PC HOST PC 9 4 8 7 2 RS22 PORT RS22 PORT 9 4 8 7 2 Fig. Connection diagram GFM to I/O22 Fig. 2 Connection diagram GFC to I/O22 2

APPENDIX 4 Warranty Aalborg electronics products are warranted against defects in parts and workmanship for a period of one year from the date of purchase. Proper product selection is the responsibility of the customer. It is deemed the responsibility of the customer that only operators with at least basic knowledge of the equipment and it s limitations are permitted to control and operate the equipment covered by this warranty. Anything to the contrary will automatically void the liability of Aalborg and the provisions of this warranty. Defective products will be repaired or replaced solely at the discretion of Aalborg at no charge. Shipping charges are borne by the customer. This warranty is void if the equipment is damaged by accident or misuse, or has been repaired or modified by anyone other than Aalborg or factory authorized service facility. This warranty defines the obligation of Aalborg and no other warranties expressed or implied are recognized. Note: Follow Return Procedures In Section a.. Aalborg7 reserves the right to change information and specifications in this manual without notice. Aalborg7-is a registered trademark of Aalborg Instruments & Controls. The selection of materials of construction, is the responsibility of the customer. The company accepts no liability.