AIR COOLED MODULAR RECTIFIER

Similar documents
The PCI Series. Precise power control for complex SCR applications. Phase Angle Fired SCR Power Controls AMPS VAC

PHASETRONICS. SCR Power Control Specialists. EP1 Series Power Control Single Phase SCR Amps OPERATION & SERVICE MANUAL

SECTION SOLID-STATE REDUCED VOLTAGE STARTERS

Liebert AccuVar (ACV Series) Surge Protective Device (SPD) (With Noise Filtering) GUIDE SPECIFICATIONS for a Parallel Surge Suppression System

SagFighter Active Voltage Conditioner / Sag Ride Through (SRT)

2.) Cabinet setup and preset data shall, as standard, be fully user programmable on a per cabinet or system wide basis.

(1986; Rev. 1989) Molded Case Circuit Breakers and Molded Case Switches. (1985; Rev. 1988) Enclosures for Electrical Equipment (1000 Volts Maximum)

The City of Winnipeg Dry Type Transformers up to 600 V Primary Section Bid Opportunity No Page 1 of 2

Standard SureVolt Power Conditioner / Voltage Regulator

MAINTENANCE MANUAL. EDACS REDUNDANT POWER SUPPLY SYSTEM 350A1441P1 and P2 POWER MODULE CHASSIS 350A1441P3, P4, AND P5 POWER MODULES TABLE OF CONTENTS

SECTION SWITCHBOARDS

PLT. Breaker-based transfer switch open, closed or soft transition amps. Specification sheet

PRODUCT. Battery Charger

PART 1: GENERAL PART 2: PRODUCT. Effective: 12/29/10 Page 1 of 6 FECA-TE-104D

POWERVAR SECURITY PLUS SERIES DETAILED UPS SPECIFICATION (8kVA 10kVA)

SECTION VARIABLE FREQUENCY MOTOR CONTROLLERS (VFD)

SECTION TRANSIENT VOLTAGE SUPPRESSION FOR LOW-VOLTAGE ELECTRICAL POWER CIRCUITS

SECTION VARIABLE FREQUENCY DRIVES

HUBBELL SPIKESHIELD Wired-In Branch Panels Surge Protective Device (SPD)

MiniEVR Electronic Voltage Regulator-Power Conditioner (MEVR)

PowerFlex 40 Sample Specification

PDI Modular Compact Remote Power Panel

RL Line/Load Reactors

Title Power Supply Units for Signalling Equipment - DC (Regulated & Filtered) Units. Reference Number SPS 30 - (RIC Standard: SC SP)

GE Digital Energy. Power Quality

SECTION SURGE PROTECTION DEVICES. A. Section includes Surge Protection Devices for low-voltage power, control, and communication equipment.

Vector Drive - Troubleshooting Guide

SECTION DISTRIBUTION SWITCHBOARDS

Quantum Chargers Enhanced AC Line Transient Immunity

3a. IEM Indoor Metal Clad Medium Voltage Switchgear 25KV a. Section INDOOR METAL CLAD MEDIUM VOLTAGE SWTICHGEAR (Std.

TRI-SERVICE ELECTRICAL WORKING GROUP (TSEWG) 07/16/08 TSEWG TP-3: SURGE PROTECTOR PERFORMANCE AND EVALUATION CRITERIA

MICRO BURN IN PRODUCTS LISTED IN MODEL NUMBER ORDER FOLLOWED BY A BRIEF DESCRIPTION

SECTION PANELBOARDS. A. NECA (National Electrical Contractors Association) -Standard of Installation

Model HM-535 Power Supply Installation and Service Instructions

Overview Included in the Box: Pinout Installation Power Supply Stepping Motors DIP Switch (JP1) Location...

RT12-240V/2.4kW Rectifier Specification

JK Series POWER DISTRIBUTION. Solid State Starters Medium Voltage A

Medium Voltage Metal-Enclosed Thyristor-Switched Harmonic Filter Banks

Application Techniques CENTERLINE 2100 Motor Control Centers

MCFCW-20-4HS-1 (4-Pipe) High Static Chilled/Hot Water Ceiling Concealed Cased Fan Coil 208/230V 4-Pipe Heating & Cooling Fan Coil 60,000 BTUH

MCFCW-08-4LS-1 (4-Pipe) Low Static Chilled/Hot Water Ceiling Concealed Cased Fan Coil 208/230V 4-Pipe Heating & Cooling Fan Coil 24,000 BTUH

ASCO 920 Remote Control (RC) Switches

SPECIAL SPECIFICATION 1864 Pole Mounted Cabinet

STATE OF NEW JERSEY BUREAUS OF ITS ENGINEERING AND SAFETY & DATA DEVELOPMENT DEPARTMENT OF TRANSPORTATION TRENTON, NEW JERSEY 08625

MCFCW-06-4HS-1 (4-Pipe) High Static Chilled/Hot Water Ceiling Concealed Cased Fan Coil 208/230V 4-Pipe Heating & Cooling Fan Coil 18,000 BTUH

RT4F-120V/20A-WAC RECTIFIER

Installation and Operation Manual

GENERAL UL th EDITION DESIGN-BUILD SPEC: SURGE PROTECTIVE DEVICES Prepared by THOR SYSTEMS, INC.

Table of Contents. Safety. Attention. Warnings

INSTALLATION, OPERATION AND MAINTENANCE MANUAL GE TRANQUELL Series Wall Mounted Low and Medium Exposure Surge Protective Devices (SPDs)

Electrical Integration of PV Systems. Ridha Hamidi, Ph.D.

PanelView Plus/VersaView CE Terminals and Display Modules

GENERAL UL th EDITION BID SPEC: SURGE PROTECTIVE DEVICES Prepared by THOR SYSTEMS, INC.

Specification Number: Product Name: FRENIC-Mega AC Drives for General Purpose Applications (½ - 150Hp at 230V and ½ Hp at 460V)

B60 Domestic Voltage Optimisation Unit. Installation Manual

Maximum Reliability & Excellent Value. Features. UL Listed Withstand & Close-On Ratings. Series 300 Power Transfer Switches

MAJOR VA Power Inverter

MP7. Uninterruptible Power Supply

SECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS

R E C T I F I E R I N V E R T E R C O N V E R T E R MP7

Service Instructions. Conductor 420

Installation, Testing, and Operating Procedures 30 AMP PORTABLE AND PERMANENT SERIES GFCI SINGLE and MULTIPHASE

Installation Manual. APEX Series. Silicon and MOV Panel Protection. APEX Series

920 Remote Control (RC) Switches

ME3 Mobile Cabinet Three Phase Frequency Converter, Operation and Maintenence.

CPS Industrial Power Supply

Medium Voltage Metal-Enclosed Power Capacitor Banks

SAMPLE. MOVs are sometimes referred

Est Constant Current Regulator MC4 3kW 30kW

Medium Voltage Metal-Enclosed Harmonic Filter Systems

B. System Design and Performance Requirements

RT4F-48V/50A-WAC RECTIFIER

B60 Domestic Voltage Optimisation Unit

TR150 DRIVE STANDARD FEATURES

OVP. The Over-Voltage Protector (OVP) Technical Literature

QUALITY POWER SOLUTIONS BACKED UP BY REAL-WORLD ENGINEERING EXPERIENCE

RT4F-110V/25A RECTIFIER

USER MANUAL INSTALLATION MANUAL. Isolation transformers. ITR Isolation Transformer 7000 W 230V/32A

EMS. Electrical Management System. Progressive Industries Incorporated Morrisville, North Carolina

Introduction to Proper Variable Frequency Drive Installation Practices. Copyright 2012 Rockwell Automation, Inc. All rights reserved.

The power factor of the typical switching power supply is between 0.4 and 0.6.

IPS INTELLIGENT PUMP STARTER

Modes of Operation The UPS shall be designed to operate as a true on-line system in the following modes:

5.1. Motor Protection and Monitoring. Contents. Product Overview. Monitoring Relays. D64R Series Digital Ground Fault Relays...

I-Line Panelboards. Innovative design, smart bus technology, and simple installation

OVP2. The Over-Voltage Protector 2 (OVP2) Technical Literature

S66 Series Electronic Fan Speed Control

Rhino PSM Power Supplies. Operating Instructions

CUS150M1 Instruction Manual

SECTION PANELBOARDS

Basic Characteristics Data

PRM MODEL TABLE. (1) Measured at 115V a-c source.

PART 1: GENERAL PART 2: PRODUCT. Phone: Fax: Web: -

C C CIRCUIT-BREAKERS Moulded-case (MCCB), general. 1. Introduction. 2. General description

Electrical Management System (EMS) EMS-HW30C & EMS-HW50C

PG Softstarter Installation Manual for 5A, 9A and 16A Controllers

Laboratory Switch Mode Power Supply Series. Instruction Manual

Bulletin 1489 Circuit Breakers. Selection Guide

Series AM4T-Z 4 Watt DC-DC Converter

Understanding Solid-state relays

Transcription:

CONTROLLED POWER COMPANY SPECIFICATIONS AIR COOLED MODULAR RECTIFIER Spc1800a1 5JAN1999 SPECIFICATION S-1800-A MODULAR (REMOVABLE AND NON-REMOVABLE MODULES) AIR COOLED RECTIFIER Standard output power range: 6 to 600 volts at 37 to 36,000 amperes TECHNICAL SPECIFICATIONS General Standards The following specification describes Controlled Power s modular Draw-out and Nondraw DC power supplies. All systems are designed and built to assure maximum reliability, flexibility, serviceability and performance. Controlled Power meets the individual needs of their customers through options and system customizing. The D. C. Power Supply is designed and manufactured in accordance with the following: National Electric Code (NEC) current edition American National Standards Institute (ANSI) National Fire Protection Association (NFPA-70) National Electrical Manufacturers Association (NEMA) Performance Specifications Input Voltage Standard Voltages: 240 or 480 Volts, 3 Phase. Optional Voltages: 208, 380 or 600 Volts, 3 Phase. Input Line Variation Standard: +5% from nominal. Optional wider ranges available. Frequency Standard: 60 hertz. Optional: 50 hertz. Efficiency Typically 85% to 93% Power Factor Typically 90% at full output Reliability 16,598 hours (MTBF) Voltage Regulation + 0.5% of full rating Current Regulation + 0.5% of full rating Ambient 0 º C (32 º F ) to 40 º C (104º F) Maximum Humidity 95% non-condensing. Elevation Maximum elevation 5000 feet (1524 meters). Storage -20 C (-4 F) to 50 C (122 F) 1

Regulation Solid state regulation of the output power is accomplished by means of Thyristors (silicon controlled rectifier, SCR) a solid state device with extremely long life, high efficiency and superior power factor. Thyristor regulation provides full range control, with or without a load, affording maximum operating flexibility and minimum maintenance. Transformers All power transformers are protected with a dedicated circuit breaker. The design of the power transformers section of this power supply is of the highest quality and reliability. The power transformers is a ventilated, dry type. The primary circuit is (3) three phase, ungrounded, delta connected. The secondary is either wye or double wye with or without interface as needed. The transformer has separate primary and secondary windings, auto-transformer types are not used. All electrical conductor material is high conductive electrolytic copper of not less than 98% of the international annealed standard for conductivity. Insulation is Class 200 (200 C rating), designed to operate within safety margins. There is a double layer arc resistant barrier (nomex) between the primary, core and secondary windings to minimize the possibility of shorts. All transformer leads are supported so that the weight is removed from the coils and they are securely braced to prevent damage in transit and during installation. All cores are manufactured from a high-grade, grain oriented silicon steel with highmagnetic permeability, low hysteresis and eddy current losses. Magnetic flux densities are kept well below saturation to allow for a minimum of 5% over-voltage excitation. All laminations are free from burrs and stacked without gaps. All transformer coils and connections are thoroughly braced for the magnetic stresses for short circuits of 18.0 times the rated base RMS symmetrical current, phase to phase, or phase to neutral for a period of 3.35 seconds. The transformer is constructed to be capable of withstanding, without damage, the mechanical stresses of an external short circuit or ground fault of this magnitude while rated primary voltage is maintained. Rectifier Circuit Diodes A wye secondary, ANSI circuit No. 23 standard 34.2 or a double wye with interphase transformer ANSI circuit No.35A standard 34.2 is used. Output rectification is by means of Diodes. Diodes have a minimum Peak Reverse Voltage rating of 2 ½ times the Maximum D. C. voltage. The design for maximum junction temperature is 80% of the manufacture s allowable rating. 2

Ripple Cooling Cabinet Thyristors 5% Rms. AC ripple at unit full output rating. Filtering can be added as an option to reduce the percentage of ripple if required. Cooling is accomplished by circulating ambient air across the heat generating components with axial fans. The cabinets are all steel construction built to NEMA 1 standards. The metal is pretreated with a phosphate coating and finished with a baked-on enamel paint to resist corrosion, marring or scratching. The thyristors (SCR) are rated for continuous full load operation. An optional auxiliary sensing circuit is available to detect a phase imbalance in the unlikely event of a device failure. This circuit insures no fault load will be placed on the remaining devices. The thyristor assembly is designed for a maximum junction temperature not to exceed 80% of the maximum rated junction temperature of the device to prolong the life of the device. The peak inverse and forward voltage ratings of the devices are at least 2 ½ times the peak voltage of the AC supply. The devices are mechanically clamped and mounted to an extruded heat sink in a manner which insures less than 10 C difference between the device and the heat sink. The heat sink is designed to provide proper cooling and to limit the maximum temperature rise to 40 C. This design is in conjunction with the appropriate air CFM maintained on the heat sink. The heat sink is machined to exceed thyristor manufacture specifications. Transient voltage surge protection limits the maximum transient voltage to less than 2.5 times the peak inverse voltage of the device. This protects each device from surges caused by switching and other alternating current variables. Primary Protection Primary protection is provided by means of an AC Thermal Magnetic Circuit Breaker. This breaker is sized to interrupt the fault current of normal installations. An optional fast acting AC current unbalance circuit which shuts the rectifier down under fault conditions is available. 3

System Protection Circuit breakers in lieu of fuses are utilized throughout to protect the power circuits. Module Protection Controls In the event of a transformer or diode short circuit failure, a magnetic circuit breaker will automatically disconnect the faulty power module from the incoming line. The power supply is automatically de-rated by the faulty increment so that the remaining power sections do not assume a larger than rated load. The operator s control panel is on the door of the control enclosure and includes the volt meter, ammeter, control potentiometer, volt/amp switch, start/stop/power off push buttons and some option components may also be included. Automatic Controls MICROPROCESSOR BASED CONTROL SYSTEM This system provides accurate repeatability and programmable features. CONSTANT VOLTAGE CONTROL This control maintains the preset output voltage constant to within +0.5%. The control limits the output of the DC power supply to a safe level if an excessive load is placed on the power supply. CONSTANT CURRENT CONTROL This control maintains the selected output current constant to within +0.5% over a 10-100% voltage range with varying input voltages and loads. If the load is removed, the voltage will rise to a preset limit value. DC OVERLOAD Digitally enhanced overload circuit allows selection of one of four settings from zero (0) to three (3) restart attempts once excessive output current is detected. Upon overload detection, the circuitry will disable the DC output, ramp the output back to it s set level within five (5) seconds and continue operation without interruption as long as the excessive load has cleared. Upon exceeding the selected number of restart attempts if the excessive load has not been cleared the unit will shut down. The overload level is factory adjusted for 5% over the units rated current output. OPTIONAL CONTROLS Fast acting AC current unbalance circuitry detects AC current unbalance and shuts down the DC power before serious damage may occur. 4

OPTIONAL CONTROLS continued Automatic slope is digitally stepped to ramp the DC power at an adjustable rate. One (1) of two (2) standard time frames may be selected. Zero (0) to two (2) minutes or zero (0) to twenty (20) minutes. Optional longer times frames are available. Signal conditioners fully isolate interface signals to control and monitor the DC output. One of the following signals can be specified 4-20 miliamp, 0-10 volt or 0-5 volt. Amp Hour Counter allows the accumulated ampere-time product to be continually monitored for chemical replenishment or maintenance scheduling. Parallel control circuit for balanced operation allows two (2) or more units to be operated in parallel for increased current output levels to a load. Cycle timer with optional alarm for time controlled operation. Gating Circuitry DC Output Warranty SOFT START The output voltage is ramped from zero (0) to the set value in a minimum of 300 milliseconds by electronic circuitry limiting damaging current surges at start-up. SYNCHRONIZATION A Phase Lock Loop circuit digitally produces synchronized gating signals for proper gating and insures that all phases are present before gating commences. INHIBIT CIRCUITS (optional) A potential free contact controlled circuit can disable the gate card to remove gate signals from the thyristors. (Contact closure enables the gate signals). An automatic absolute zero gate inhibit circuit board will disable gate signals and suppress leakage whenever the output is set for zero (0) in voltage or current mode of control. The DC output of the unit is floating. Either terminal may be grounded. The output terminals are located inside the unit or covered when the output voltage is 50 volts or greater. The system is guaranteed against defects in material and workmanship for one (1) year from the date of shipment. 5