GF92 Installation, Operation and Troubleshooting Guide

Similar documents
GF90 Installation, Operation and Troubleshooting Guide

Installation, Operation and Maintenance GF90 and GF92 [ ] Model GF90 Insertion. Model GF92 In-Line Doc 06EN003229

Scanner 2000 microefm QuickStart. Installing the Scanner Remote Mount. Direct Mount NUFLO. Part No , Rev. A

PS/IO Circuit Board Retrofit

CDD4 Duct Carbon Dioxide Transmitter

Replacing the Power Supply

Instruction Manual. M Pump Motor Controller. For file reference, please record the following data:

MODEL SW6000 & SM6100 CENELEC INSTRUCTIONS

DWYER INSTRUMENTS, INC. Series AVUL Air Velocity Transmitter. Specifications - Installation and Operating Instructions.

CDD Carbon Dioxide Transmitter

Quick Start Guide MC-III TM Flow Analyzer

Resolver to Digital Expansion Board

Analog Monitor Installation Manual

Ag Leader Technology. DirectCommand Installation Hardi 20-pin Interface Kit (Sprayer Chassis Mount)

PowerFlex DC Drive - Frame A Switching Power Supply Circuit Board

CDD4 Series Room CO2 Transmitter Installation Instructions

Torque Series LCD Remote Panel Installation/Operation Manual Model: TQ-DSP-12/24

Differential Liquid/Gas Pressure Transmitter

RMB Peripheral Units Installation Guide

TPE 1464 Series Pressure Transducer

Carbon Monoxide Sensor - ModBus

Your Global Flow Control Partner. Series 50 Valve Status Monitor Operation and Maintenance Manual

Sidewinder Pumps Inc. AC C1D2 Timer/Controller

Table of Contents. General Information. Document Sure-Aire Flow Monitoring System. User and Service Manual WARNING CAUTION

Part Name/Description Part Number Quantity

Instruction Sheet Board Style Low Water Cutoff

MAXIMA+ Series Rotary Level Indicator

PowerFlex DC Drive Frame B Pulse Transformer Circuit Board

VertX. V100, V200 and V300. Installation Guide Barranca Parkway Irvine, CA USA. November Rev A.1

Adapter Kit - QSI Electronics to TM Meter Installation Instructions

E101 - Strain Gauge Transducer Display Module. Contents

Configuration Software Manual

Scanner 2000 Steam Mass Flow Transmitter

KOBOLD TDA Series Digital Temperature Transmitter

Cutter Option Installation Instructions

MYRIAD QLC 4-CHANNEL MONITOR/CONTROLLER INSTRUCTION MANUAL

Installation manual CF8-W-Disp-AL

KOBOLD PDA Series Digital Pressure Transmitter

MAXIMA + Series ROTARY LEVEL CONTROL

Installation Guide. Carbon Dioxide (CO 2. ) Detectors. General Information. Mounting WARNING CAUTION. SAE-1011/1012 Space Mount SAE-1011/1012/1062

TRC-190 User s Manual

Part Name/Description Part Number Quantity

Model HU-224/225. Technical Information TI.224/ Humidity Transduce r FOR ADDITIONAL INFORMATION SEE HU-224/225 DATA SHEET

OilCop Component Wiring Installation Manual

LTEC Heat Pump DDC Controller

Security Management System by Diebold, Inc. LINX System Hardware Installation Guide

OPERATING INSTRUCTIONS

Research Concepts RC2500 Antenna Interface Unit (AIU) Board Set

Flomatic Smart Card TM Model FDHC-100 (Digital High-Resolution Controller) Configuration and Operation Manual

DSTHM-2 COMBINED T AND RH DUCT TRANSMITTER. Mounting and operating instructions

Model 2380 Rack-Mount Kit

WOODINVILLE, WA SUPERSTEP 2100 SERIES SEQUENCING PROPORTIONAL LOAD CONTROLLERS INSTALLATION & OPERATING MANUAL. Models: SLC2102-SLC2112

MYRIAD LC1 LEVEL CONTROLLER INSTRUCTION MANUAL

M5 and M10 Routers Power Supply and Power Cord Component Replacement Instructions

JR3 EXTERNAL SENSOR ELECTRONICS WITH ANALOG OUTPUT. JR3, Inc. 22 Harter Ave. Woodland, CA 95776

RMB-3 Peripheral Unit. Installation Guide INSTALLATION GUIDE WESTELL.COM. Westell Technologies Part # Rev. A

Model 2380 Rack-Mount Kit

Adapter Kit - QSI Electronics to G-Series Meter Installation Instructions

InView Marquee Message Display

DirectCommand Installation RoGator Model Year Ag Leader Technology

FlexCOR Model CMF Series

PowerFlex 755 Common DC Input Drives, Frames Interlock Assembly and Precharge Assembly Left-front Cover Retrofit Kit

Smart Wireless THUM Adapter

TraceTek Leak Detection Master Module Installation Instructions TOOLS REQUIRED STORAGE

AirTest Model CN9000 Series Sensor Controller

Plasma Panel Replacement Guide DU-42PX12X

3710 ACM 3750 PDC 3800 RTU. ISOCOM Communications Card Retrofit Instructions

SITRANS F. Flowmeters SysCom Upgrade Kit IP65 (NEMA 4X) Multi-Channel. Introduction 1. Installing/Mounting 2. Hardware Installation Instructions

Zero Volt Monitor Installation, Operation and Maintenance

Manual Control Unit GFC 32

CPCI-PS24 24V-Power Supply

IRB-RET O P E R A T I N G I N S T R U C T I O N S UNIVERSAL SAFETY RETROREFLECTIVE PHOTOEYE U L M O N I T O R E D DEVICE

UNT1100 Series. Binary Output Jumpers AO2 AO1 AO3 AO4 AOCM AOCM AOCM AOCM AO1. AI Switches Job Information N2 Address. Ref N2+ N2- ADDR 0 = ALL OPEN

Note: These installation instructions are only for the 4430/4440 Sprayer. For other SPX models please refer to P/N , &

Installation Instructions

Analog Input Installation Manual

Twisted Nitro Stunt Racing New Cabinet Design with Sintra Marquee Supplement to Operation & Service Manual

FLOW MONITOR & TRANSMITTER

Configuration Software Manual

Butterfly Laser Diode Mount

INSTALLATION INSTRUCTIONS

TRC-190 User s Manual

AI130 AIswitch Series 130 Chassis Installation Guide

Smart Multivariable Transmitter (SMV 3000) Electronics Module Replacement Kit Instruction

Adapter Kit - QSI Electronics to G2 Meter Installation Instructions

Installing and Removing SDRAM and DRAM

JR3 EXTERNAL SENSOR ELECTRONICS WITH SERIAL DATA OUTPUT. JR3, Inc. 22 Harter Ave. Woodland, CA 95776

3% VOLTAGE DROP. Installation Instructions for 100 Watt 24 Volt DC RGB DMX LED Power Supply SAVE THESE INSTRUCTIONS!

istar Pro Installation Guide

RVDT Setup and Polarity Checking Tool for EG Governors. Product Manual (Revision B) Original Instructions T87444

60W Power over Ethernet Waterproof Adapter PoE IEEE BT Single Port Injector for Outdoor Application

Model XAV2 & XAV2-LED System Installation

IRB-RET O P E R A T I N G I N S T R U C T I O N S UNIVERSAL SAFETY RETROREFLECTIVE PHOTOEYE U L MONITORED DEVICE

5B Series 16 Channel Backplane 5B01 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

ELECRAFT P3 HIGH-PERFORMANCE PANADAPTER P3SVGA OPTION INSTALLATION AND OPERATING INSTRUCTIONS. Rev B, March 20, 2012

CableUPS Quick Start Guide

Installation Note. Source Attenuators and Bias Tees Upgrade Kit. For E8362B/C PNA Series Microwave Network Analyzers. Network Analyzer Model Number

PGR-4700 MANUAL SENSITIVE GROUND-FAULT RELAY

Thermometer / Barometer System

PowerFlex DC Drive - Frame A SCR Modules for Drives with a Power Traces Circuit Board

Transcription:

24 Hour Factory Service Hot Line: 1 (800) 854-1993 GF92 Installation, Operation and Troubleshooting Guide Document 06EN003321 Rev. - A. To get the best results from the instrument, the sensor should be located 20 pipe diameters downstream from any flow disturbance (valve, pipe elbow, etc.) and 10 pipe diameters upstream from any disturbance. The instrument tags show the model number, tag number (if noted on the customer s order), serial number along with other important safety information. Compare this information with the appropriate pipe installation drawings and calibration sheets to verify the instrument is the correct configuration. Tag Location - Between Conduit Ports On Local Enclosure Tag Location - Top Side of Remote Enclosure If the instrument is a remote configuration, the serial number on the enclosure tags must match. The recommended tag number on the local enclosure will have an FT in the tag number. The recommended tag number on the remote enclosure will have an FE in the tag number. (Tags are specified by the customer, FE/FT is a recommended naming convention.) B. Verify the serial numbers on the enclosure(s), flow element and electronics match. The instrument may not work if the serial numbers do not match. (The instrument has a remote transmitter enclosure (FT) and a local flow element enclosure (FE).) Flow Element Serial Number Also Showing Flow Arrow (Located near the FE enclosure. It is also on the enclosure tag.) Electronics Serial Number (Top circuit board, lower left corner. It is also on the transmitter s (FT) enclosure tag. C. Recommended installation/troubleshooting tools are an open-ended wrench to fit the NPT connection, an openended wrench to fit the flanged fitting nuts and bolts, a small flat blade screw driver for manipulating potentiometers, both a medium flat blade screwdriver and a medium phillips head screwdriver for tightening connections, 3 mm allen wrench for CENELEC approved instruments, a measuring tape for proper flow element placement, and a DVM for Ohm/Voltage measurements.

Step 2. Flow Element Installation Alert: DO NOT change the orientation of the flow element in the enclosure as the interconnecting RTD and heater wiring could be stressed and damaged. DO NOT apply any torque to the flow element enclosure - only apply to the pipe surface itself. Install the flow element, with the flow arrow (shown on Page 1) in the direction of media flow. The remote enclosure, local enclosure, flow element and electronic transmitter serial numbers must all match. For flange mount flow elements, attach the process mating flange with care. The correct orientation of the flow element must be maintained to ensure the calibrated accuracy. Verify that the process media flow is in the same direction as the arrow on the flat machined area. Apply the appropriate gasket and/or sealant to flange mount as required. Mate flow element flange to process mount keeping flat oriented properly. Attach with bolt, two flat washers, lock washer and nut for each bolt hole, apply lubricant/sealant to male threads and torque. Refer to ANISI B16.5 specifications. For NPT pipe thread installations, apply sealant to the male threads. Carefully place in the process media line with the machined flat facing up. Tighten the process connections. To avoid leaks do not overtighten or cross-thread connections. Shown below is the NPT mounting option. Other options are flange mount and butt weld mount. See the Installation Section in the GF Series Manual, Document Number 06EN003229 for more details. In-Line GF92 Flow Element and Enclosure Local NEMA 4 &7 Enclosure Dimensions Remote Enclosure NEMA TYPE 4X Dimensions (Option) Remote Explosion Proof Enclosure Dimensions (Option) Model GF92 Flowmeter 2 Doc. No. 06EN003321 Rev.-

Step 3. Wiring Preparation Before the instrument is opened to install the wiring, FCI recommends that the following ESD precautions be observed: Use a wrist band or heel strap with a 1 megohm resistor connected to ground. If the instrument is in a shop setting there should be static conductive mats on the work table and floor with a 1 megohm resistor connected to ground. Connect the instrument to ground. Apply antistatic agents such as Static Free made by Chemtronics (or equivalent) to hand tools to be used on the instrument. Keep high static producing items away from the instrument such as non-esd approved plastic, tape and packing foam. The above precautions are minimum requirements to be used. The complete use of ESD precautions can be found in the U.S. Department of Defense Handbook 263. Open the instrument enclosure to expose the terminal strips. The orientation of the connectors are shown below: JP5 RELAY 2 JP3 - CUSTOMER JP6 WIRING TO FLOW AUXILIARY & ELEMENT SIGNAL OUTPUT JP4 RELAY 1 SWITCH S1 ( 115VAC 230VAC) JP1 AC OR DC POWER FUSES Step 4. Wiring the Instrument GF92 Terminal Strip, Power Option Switch and Fuse Orientation Caution: Only qualified personnel are to wire or test this instrument. The operator assumes all responsibilities for safe practices while wiring or troubleshooting. Alert: The instrument contains electrostatic discharge (ESD) sensitive devices. Use standard ESD precautions when handling the flow transmitter. Wiring the Instrument into the Customer Application: This section describes wiring to the transmitter inputs, outputs and interconnection cabling for the remote enclosure. For best results route the output wiring through the opposite port from the power wiring. See the table on the next page to determine the size of wiring to be used versus the length of the wire. Doc. No. 06EN003321 Rev. - 3 Model GF92 Flowmeter

Connection 10 ft. (3m) 50 ft. (15m) Maximum Distance for AWG 100 ft. (31m) 250 ft. (76m) 500 ft. 152m) 1000 ft. (305m) AC Power 22 22 22 20 18 16 Relay (2A, at 220VAC) 24 22 20 16 12 Not Recommended Relay (10A, at 120VAC or 24VDC) 22 16 12 Not Recommended Flow Element Wires 24 24 24 22 22 18 for Remote Option* Wire Gauge Versus Distance Of Wire To Run Wiring the Instrument s Signal Output to the Customer Application: For Current Output: 4-20 ma; connect a positive wire to + I OUT and a negative wire to OUT COM. For Voltage Output: 0-5, 0-10 or 1-5 Vdc; connect a positive wire to + E OUT and a negative wire to OUT COM. Analog Output 2 is connected in a similar manor as Analog Output 1. ( For Voltage Output: 0-5, 0-10 or 1-5 Vdc; connect a positive wire to + E OUT2 and a negative wire to OUT 2 COM. For Current Output: 4-20 ma; connect a positive wire to + I OUT2 and a negative wire to OUT 2 COM.) See GF Series manual 06EN003229 for details. Customer Connections, Analog Output Diagram Analog Output Plug Location Alert: Either voltage or current from the Analog Outputs can be connected to the customer application, not both. (Example: Voltage and current from analog output 1 cannot be connected.) However, one Analog Output can be wired for current and the other Analog Output can be wired for Voltage. Model GF92 Flowmeter 4 Doc. No. 06EN003321 Rev.-

Wiring the Flow Element: Connect a shielded, 8 wire cable between the transmitter and the local enclosure terminal strip as shown below. Be sure the shield (ground wire) is connected to JP3 GND along with the wire from terminal block terminal 2. Do not connect the shield to the local enclosure (leave it floating). Local Enclosure Wiring Diagram Flow Element Transmitter Terminal Block JP3 (Terminal No.) Terminal 5 (ACT) ACT SEN (4) Terminal 5 (ACT) ACT EXC (6) Terminal 4 (GND SEN) GND SEN (2) Terminal 3 (REF) REF SEN (3) Terminal 3 (REF) REF EXC (5) Terminal 2 (GND) GND (1) Terminal 1 (HTR) HTR EXC (7) Terminal 1 (HTR) HTR SEN (8) Flow Element Wiring Table Flow Element Wiring Diagram (Be sure the jumper is in place Terminal 2 to terminal 4.) Connector JP3 Wiring the Output Relays: The instrument contains two sets of alarm output relays (connectors JP4 Relay Output 1, and JP5 Relay Output 2). They can be wired by the customer as desired. (NO = Normally Open, NC = Normally Closed, Pole = Common) Output Relay Wiring Diagram Connectors JP5. and JP4 Doc. No. 06EN003321 Rev. - 5 Model GF92 Flowmeter

Wiring the Input Power: Caution: FCI recommends placing an ON/OFF switch in line with the power source. When JP1 is connected to the power source the instrument is ON. AC or DC power can be used to operate this instrument. For best results route the output signal wiring through the left port of the instrument enclosure and the power input wiring through the right port. See the wiring table on Page 4 to determine the minimum size of wiring to be used versus the length of the wire run to the power source. 115 or 230 VAC Power Option The input power can be switched from 115 Vac to 230 Vac by moving switch S1 to the correct setting. (The instrument requires only AC or DC to be connected, not both.) Connect the hot side of the AC Line to AC Line, the neutral side to AC NEUT, and ground to EARTH GND. (Do not connect the local enclosure shield wire to the EARTH GND on this plug.) 24 VDC Power Option If DC power is used, the AC Input and switch S1 are not pertinent. Wire the positive 24 volt input to +24V. Connect the negative wire to DC GND. Switch S1 Connector JP1 Input Power Location Input Power Wiring Diagram Step 5. Operation The instrument has been configured and calibrated to custom specifications. In-depth programming of the instrument in the field should not be necessary. Apply power to the instrument. Wait 10 minutes for the instrument to stabilize. During this period the instrument may indicate a high flow condition. When the instrument is powered up, the instrument will display an initialization sequence. Then the instrument will display the normal operation information. Shown below is the normal operation window. Output Channel # Flow Rate CH1: 5056.3 SCFM CH2: 71.2 F 435226 SCF (grp1)(ed)(norm)(m) Flow Units Process Temperature Totalizer (If Enabled) Sample (Flashes) Rate Calibration Group # Relay Status Mode Normal Operation Window Model GF92 Flowmeter 6 Doc. No. 06EN003321 Rev.-

Menu Control The prompt line displays appropriate key strokes for the required menu level. If a key is pressed that is not valid for that menu, Invalid Response will flash briefly across the prompt line. The key pad and key assignments are shown below: Menu Level Title Available Selections 3.1.2 STD VOLUME 1=Cu feet 3=Cu meter 3=Liters (CF)? Current Selection Prompt Line Display Characteristics 1 2 3 Y N 4 5 6 _. 7 8 9 P ENTR 0 # HOME UP Key Pad Key Key Name Action 0-9 Numeric Selects options and enters numbers Y Yes Enter a yes response N No or (N)ext Enter a no response or scrolls to the next screen - Minus Enter a minus sign Decimal Point Enter a decimal point Back Space Moves cursor back one space P (P)rv or Previous Scrolls to the previous screen ENTR HOME UP Enter Home Up Enters a numeric value or response Returns to the Main Menu or escapes from routines Move current menu up one level Key Assignments At any time, the HOME key can be pressed and the main menu will display. HOME can be used to escape from most routines, or restart a progression into the menu structure. When (N)ext is displayed on the prompt line, more than two menu selections are available. Press N to scroll through all the selections. The UP key, will back-out of a menu level. The menu moves back one level each time the UP key is pressed. The UP key only functions when UP is displayed on the prompt line. To make a selection, press the numeric key associated with the desired menu selection. The selection does not have to be displayed, but it must be one of the available selections. The quick operation menu is shown below: 0.0 MAIN MENU 1 = Normal Operation 2 = Port Setup 3 = Display Setup 4 = Miscellaneous CH1: 5056.3 SCFM CH2: 71.2F = 435226 SCF (grp1) (dd) (mode N) (m) Normal Operation QUICK OPERATION MENU 2.0 PORT SETUP 1 = Analog Output 2 = Relays 3 = Comm Output 4 = Aux Input 3.0 DISPLAY SETUP 1 = Flow Setup 2 = Temperature Setup 3 = Totalizer Setup 4 = Sample Rate 4.0 MISCELLANEOUS 1 = Set Group 2 = Corrector Setup 3 = Password Setup Doc. No. 06EN003321 Rev. - 7 Model GF92 Flowmeter

Step 6. Troubleshooting In the event that the instrument does not operate as expected use the table below: Problem Solution No Display Check Fuses (below JP1). Verify S1 is switched to the correct input voltage for AC applications. Verify correct power is applied Verify the ribbon cable between the upper and lower circuit boards is solidly connected and the red stripe is on pin 1. No Display or Dim Display Adjust pot R1 on the upper left of the top circuit board. If there is no change in the display return the pot to the original setting. Display is Locked Up Press HOME and then 1 to return to normal operation. Reset the instrument by cycling the power. Readings Seem Incorrect Verify the serial number of the flow element and the flow transmitter are the same serial number. Verify the flat on the flow element is parallel to the pipe and the flow flow arrow is pointed in the direction of the flow stream. Verify the sensor is mounted in the center of the pipe. Verify the calibration data sheet matches the process configuration. Verify all jacks and plugs are all firmly seated and the wiring to them is correct and secure. If there are still problems with the instrument, see the Troubleshooting Section in the GF Series Manual, Document Number 06EN003229. To acquire a manual call your local FCI sales representative. Notice of Proprietary Rights This document contains confidential technical data, including trade secrets and proprietary information which are the property of Fluid Components Intl (FCI). Disclosure of this data to you is expressly conditioned upon your assent that its use is limited to use within your company only (and does not include manufacture or processing uses). Any other use is strictly prohibited without the prior written consent of FCI. Visit FCI on the Worldwide Web: www.fluidcomponents.com 1755 La Costa Meadows Drive, San Marcos, California 92069 USA - 760-744-6950-800-854-1993 - Fax 760-736-6250 European Office: Persephonestraat 3-01 5047 TT Tilburg - The Netherlands - Phone 31-13-5159989 - Fax 31-13-5799036 Copyright 2001 Fluid Components Intl a limited liability company All Rights Reserved Model GF92 Flowmeter 8 Doc. No. 06EN003321 Rev.-