Product Development for Medical, Life Sciences, and Consumer Health

Similar documents
Safety-enhanced Design EDIS 2014 R (a)(1) Computerized Provider Order Entry

Usability Test Report of ClinNext 10 EHR version 1.0

Medical Device Usability

Applying Human Factors to Medical Device Design

HUMAN CENTERED DESIGN

The Human Touch: Develop a Patient-Centric Injection Device

Usability Testing. November 9, 2016

Standard Glossary of Terms used in Software Testing. Version 3.2. Foundation Extension - Usability Terms

Folsom Library & RensSearch Usability Test Plan

Usability Report for Online Writing Portfolio

FDA Initiatives on Human Factors and Usability for Medical Devices Molly Follette Story, PhD FDA /CDRH / ODE

Recent Developments in FDA s Review of Proprietary Names for Drugs

Concepts of Usability. Usability Testing. Usability concept ISO/IS What is context? What is context? What is usability? How to measure it?

Who we tested [Eight] participants, having the following profile characteristics, evaluated [product name].

User interface design. Ian Sommerville 2004 Software Engineering, 7th edition. Chapter 16 Slide 1

Foundation Level Syllabus Usability Tester Sample Exam Answers

Usability Testing Essentials

Users are always RIGHT! Usability and Eyetracking to improve web sites

!"# $ # # $ $ % $ &% $ '"# $ ()&*&)+(( )+(( )

Stream Features Application Usability Test Report

EHR Usability Test Report of SRS EHR v10

Usability Testing Methodology for the 2017 Economic Census Web Instrument

Office of the Director. Contract No:

JUST WHAT THE DOCTOR ORDERED: A SOLUTION FOR SMARTER THERAPEUTIC DEVICES PLACEHOLDER IMAGE INNOVATORS START HERE.

Usability Tests and Heuristic Reviews Planning and Estimation Worksheets

Reviewers Guide on Clinical Trials

Usability Testing. November 14, 2016

ehepqual- HCV Quality of Care Performance Measure Program

Usability Testing CS 4501 / 6501 Software Testing

The National Medical Device Information Sharing & Analysis Organization (MD-ISAO) Initiative Session 2, February 19, 2017 Moderator: Suzanne

Protocol Deviations and Protocol Violations Made Simple. Donna Brassil, MA, RN, CCRC Rhonda G. Kost, MD

Foundation Level Syllabus Usability Tester Sample Exam

USABILITY EVALUATIONS OF Health Information Technology

Acceptance Checklist for Special 510(k)

PATH Intl. Registered Riding Instructor Certification Booklet

User Testing Study: Collaborizm.com. Jessica Espejel, Megan Koontz, Lauren Restivo. LIS 644: Usability Theory and Practice

EHR Usability Test Report of IntelleChartPro, Version 7.0 Report based on ISO/IEC 25062:2006 Common Industry Format for Usability Test Reports

Usability Test Plan for Blogger Mobile Application

Therapy Provider Portal. User Guide

USABILITY IN HEALTHCARE IT: DATA COLLECTION AND ANALYSIS APPROACHES

ONC HIT Certification Program

Introduction to UKAS Accreditation Fire Scene Development Programme. David Compton November 2017

D I Y. Usability Testing

CPSC 444 Project Milestone III: Prototyping & Experiment Design Feb 6, 2018

ONC HIT Certification Program Test Results Summary for 2014 Edition EHR Certification. Modular EHR

North Carolina Fire and Rescue Commission Certification Programs POLICY FOR TESTING

SO OS Secure Online Voting System

PROGRAM GOALS

Integrating Usability Design and Evaluation: Training Novice Evaluators in Usability Testing

APPENDIX 1 7 APPENDIX 2 8 APPENDIX 3 10 APPENDIX 4 11

PNC.com, Weather.com & SouthWest.com. Usability Analysis. Tyler A. Steinke May 8, 2014 IMS 413

Usability Testing, Cont.

Usability Study: The Key Ingredient in Designing Effective Help Systems

Analytical &! Empirical Evaluation

Consumers Energy Usability Testing Report

A Comparative Usability Test. Orbitz.com vs. Hipmunk.com

How to Add Usability Testing to Your Evaluation Toolbox

Human Factors Usability in the Review of New Medical Devices FDA/CDRH. Considering Usability for Pharmaceutical Aerosol Devices.

General Guidance for Maintaining a Regulatory Binder

LNE/G-MED North America, Inc

LINCOLN COUNTY EMERGENCY MEDICAL SERVICES

EVALUATION AND APPROVAL OF AUDITORS. Deliverable 4.4.3: Design of a governmental Social Responsibility and Quality Certification System

ALABAMA FIRE COLLEGE SKILLS EVALUATOR TRAINING

A multi-perspective methodology for studying user interactions with a decision-support system

2018. All rights reserved.

Comparing Approaches to Measuring the Adoption and Usability of Electronic Health Records: Lessons Learned from Canada, Denmark and Finland

We will only ask you for information which is absolutely necessary for us to help you and that which you have consented to providing,

Methodology for Ensuring Accuracy and Validity of Infusion Pump Alarm Data

MyChart User Guide. RiverBend Medical group

CS3724 Human-computer Interaction. Usability Specifications. Copyright 2005 H. Rex Hartson and Deborah Hix.

NVIvo 11 workshop. Hui Bian Office for Faculty Excellence

MicroMD EMR version 7.7

Research, Development, and Evaluation of a FRBR-Based Catalog Prototype

USABILITY REPORT A REPORT OF USABILITY FINDINGS FOR OFF THE BEATEN PATH WEBSITE

DF/HCC Operations for Human Research Subject Registration Procedures

Rapid Research. For 2.0 Development. Presented by Kelly Goto

Experimental Validation of TranScribe Prototype Design

CUE-10: Moderation Page 1. Comparative Usability Evaluation 10. Moderation. Observing usability test moderators

National Certificate in Recreation and Sport Coaching and Instruction with strands in Cycle Skills Instructor, and Developing Coach

Institutional Review Board. Application for Research Using Humans

What is Usability? What is the Current State? Role and Activities of NIST in Usability Reactions from Stakeholders What s Next?

MMI 2. Tutorials. Winter Term 2017/18. LMU München - LFE Medieninformatik. Prof. Andreas Butz Renate Häuslschmid Christina Schneegaß

CURRICULUM MASTER OF DISASTER MANAGEMENT

ELECTRONIC SITE DELEGATION LOG (esdl) USER MANUAL

Medical Device Vulnerability Management

CENTRAL CALIFORNIA EMERGENCY MEDICAL SERVICES

Amsterdam Medical Center Department of Medical Informatics. Improve. Usability evaluation of the sign up process of the Improve app

ProScript User Guide. Repeat Management System. Version Release Date 16/02/2010 Last Reviewed 01/10/2013 Author Rx Systems

1/26/16. Usability activities are NOT clinical Trials. Usability Testing Medical Devices. It s going to feel like a clinical trial

Standards: Implementation, Certification and Testing Work group Friday, May 8, :00 Pm-1:30 Pm ET.

The ehealth Annual Report aims to highlight the activities within the teams that make up the ehealth Department.

Biosolids Land Appliers Certification

External Assessment Specifications Document Curriculum. NQF Qualification Title Code

Chapter 4. Evaluating Interface Designs

PPC Provider Directory Real-Time Updates User Guide 1

Developing a Mobile Information Service

Table of contents. TOOLKIT for Making Written Material Clear and Effective

What is New in MyChart? My Medical Record Health Preferences Settings Appointments and Visits Visits Schedule an Appointment Update Information

Compile together the individual QA Testing Checklists for your team site.

The Engineering Vulnerability Assessment Protocol - principles and application David Lapp, P.Eng. Manager, Professional Practice Engineers Canada

Transcription:

Product Development for Medical, Life Sciences, and Consumer Health

Fundamentals of Usability Testing for FDA Validation MassMEDIC April 8, 2010 Beth Loring Director of Research and Usability 2

Topics What is a usability test? Why is usability testing required by the FDA? Designing a usability test Conducting a usability test Analyzing and reporting the results 3

What is a usability test? 4

What is a usability test? The primary focus is on usability & safety Actual or potential users participate Users attempt tasks with the product, unaided Moderator leads the session, observes, records data The team diagnoses usability problems and use errors The team recommends design improvements and/or risk mitigation 5

Focus is on usability & safety Real users attempt real tasks on their own A usability test is not a research study A usability test is not a marketing study A usability test is not a preference test 6

Why is usability testing required? 7

Why is usability testing required? Portions of the Quality System Regulation that apply to human factors: Subpart C - Design Controls The need for human factors techniques or data in the design process is implicit in paragraphs c, f, and g of Section 820.30. ( g ) Design validation: "Design validation shall ensure that devices conform to defined user needs and intended uses, and shall include testing of production units under actual or simulated use conditions." Human factors relevance: Design validation should be used to demonstrate that the potential for use error that can lead to patient injury has been minimized. The regulation requires testing the device under actual or simulated use conditions. Realistic use conditions, therefore, should be carried out by test participants who represent a range of typical intended users in terms of their ability to acquire information from, manipulate, and maintain the device and understand the accompanying labeling. From the FDA -- Human Factors Implications of the New GMP Rule Overall Requirements of the New Quality System Regulation 8

Why is usability testing required? Testing for ease and accuracy of use is the only way to ensure that users can safely and effectively operate, install, and maintain devices. This process culminates in full testing of a model embodying all the user-interface characteristics for both hardware and software of a fully functioning device. -- from the FDA (1996), Do It By Design 9

Designing a usability test 10

Designing a usability test Select & recruit participants Select tasks or features to be tested Select measures Prepare the test materials Handle logistics & preparation Run a practice test 11

Select & recruit participants Selecting the right participants is key to a valid test Create an effective screener Relevant demographics should have been defined earlier Select user profiles based on the purpose of the test Who should recruit the participants? 12

Example What are some user profiles for a test of an infusion pump? How many participants? What about training? 13

Example Job Description Gender Age Groups Pumps Used Specialty Frequency of Use Group 1 (N=12) RN or NP 80% female, 20% male 25-40 (N=4) 40+ (N=8) A, B, C Pediatrics 5+ Adult non-acute times/shift Adult acute Group 2 (N=12) RN or NP 90% female, 10% male 25-40 (N=4) 40+ (N=8) A, B, C Pediatrics 5+ Adult non-acute times/shift Adult acute Group 3 (N=12) Physician 50% female, 50% male 25-40 (N=4) 40+ (N=8) A, B, C Pediatrics 1+ Adult non-acute times/shift Adult acute 14

Select tasks or features Typical or frequently performed Critical to operation Address a safety concern Performed under stress Redesigned after previous validation testing Illustrates error recovery 15

Example What are some tasks you might test on an infusion pump? 16

Example What are some tasks you might test on an infusion pump? Turn on the pump Set it up for drug administration by keying in the flow rate and volume-tobe-infused parameters Install the administration set Perform primary and secondary infusion Change parameters React to an emergency Set alarms Silence alarms 17

Select measures Objective measures Measures of performance Observable Subjective measures Preferences, opinions, impressions Base these on your usability goals Which ones can be quantified? 18

Example What are some measures you might use when testing an infusion pump? 19

Example What are some measures you might use when testing an infusion pump? Task times Number of errors Types of errors Completed tasks (%) Usability ratings Design suggestions Failure to react to alarms Preferences for control layout 20

Handle logistics & preparation Use a checklist Identify setup requirements Prepare the materials Informed consent & NDA Moderator s script Task cards Data collection tool Pre- or post-test questionnaires Run a pilot test 21

Conducting a usability test 22

Conducting a usability test Where to conduct the test? How long should sessions take? Who should moderate? Who should collect the data? Should participants think aloud? 23

Conducting a usability test Where to conduct the test? How long should sessions take? Who should moderate? Who should collect the data? Should participants think aloud? Typical outline: Introduction & informed consent Pre-test questionnaire User performs tasks Objective & subjective data collected Post-test interview and ratings 24

Moderating the session This is the art of usability testing Roles: host, leader & neutral observer Avoid bias The less you say the better! Turn the question around Give as little assistance as possible Keep control of the session 25

Analyzing and reporting the results 26

Analyzing the data Transcribe notes Review photos and video Analyze quantitative data Calculate descriptive stats Analyze qualitative data Moderator s & observers notes Questionnaires & rating sheets Lists of issues from observers Pre- and post-test interview results 27

Examples of usability issues Nurses can t figure out how to insert tubing in an infusion pump Lab technicians load disposables into the wrong drawer Nurses incorrectly program parameters in a patient monitor Patients misinterpret the LEDs on a ventricular assist device Surgeons experience pinch points with a hand-held instrument 28

Severity of usability issues Based on your hazard analysis, usability goals, and/or usability validation plan Example: Level 1: Prevents completion of task or could be hazardous Users cannot enter correct dosage Level 2: Creates delay and/or frustration Users repeat tasks because of lack of feedback Level 3: Causes minor problem Poor label choice Level 4: Would enhance usability Quick reference card needed 29

Acceptance criteria What constitutes a successful task outcome? Example: For this study, at least 26 of the 30 subjects must have registered a success for a particular scenario for the design to pass usability validation. The design must also score an average of 4.0 or higher on a 5-point scale in order to pass usability validation. Any design that fails to be successfully completed by the appropriate number of subjects or averages below a 4.0 rating will not be accepted. 30

Example Participant Task 1 Turn on device and check battery Task 2 Switch to backup Task 3 Switch to manual mode Task 4 Interpret alarms Task 5 End therapy 1 correct correct correct one error correct 2 correct incorrect incorrect two errors incorrect 3 correct correct correct all correct correct 4 correct incorrect correct all correct correct 5 correct correct correct one error correct 6 correct correct correct all correct correct 7 correct correct correct two errors correct 8 incorrect correct correct all correct incorrect 9 correct correct correct all correct incorrect 31

Communicating results to the team Informal debriefing Short memo with findings Full test report Formal presentation Highlights video 32

Preparing the FDA report There is no prescribed format Tie it back to the FMEA Was usability validated or not? Additional design changes needed? 33

Preparing the FDA report There is no prescribed format Tie it back to the FMEA Was usability validated or not? Additional design changes needed? Typical outline: Purpose Methodology Data analysis Task success rates Errors and usability issues Conclusions (pass/fail) 34

Case study: Drug delivery device Client submitted for 510(k) clearance, FDA required validation testing User profiles: Patients and health care professionals Selected tasks: All primary operating functions Measures: Objective and subjective, based on hazards analysis Materials: Two detailed moderator s scripts, training, IFUs Test environment: Market research facility Data collection: Read-time using carefully designed spreadsheets Analysis: Completed by client, reviewed by Farm Results: Showed hazards had been addressed, no new issues 35

Final thoughts Usability testing should be iterative during the design process It is required as part of design validation for the FDA Final testing must include safety-critical tasks Final testing must be done with actual users in actual or simulated environments 36

References FDA Quality System Regulations 21 CFR 820.30, Subpart C Design Controls, paragraphs c, f, and g ANSI/AAMI HE74:2001 Human Factors Design Process for Medical Devices ANSI/AAMI HE75:2009 Human Factors Engineering Design of Medical Devices (in publication) ISO/IEC 62366:2008 Application of Usability Engineering to Medical Devices Do It By Design (FDA, 1996) An Introduction to Human Factors in Medical Devices A Practical Guide to Usability Testing (Dumas & Redish) Moderating Usability Tests (Dumas & Loring) 37

At Farm, we help our clients build better tools Business Center 12 Silver Lake Road P.O. Box 1260 Hollis, NH 03049 Phone: 603 465-9800 Fax: 603 465-9801 38 Development Center 27 Proctor Hill Road P.O. Box 1260 Hollis, NH 03049 Phone: 603 465-9800 Fax: 603 465-3287 www.farmpd.com