1206P (CTS ME-X.21) MODEM ELIMINATOR, X.21 INSTALLATION AND OPERATIONS MANUAL. Doc #: UA Part #: 07M1206P-A

Similar documents
1205P MODEM ELIMINATOR, V.35 INSTALLATION AND OPERATIONS MANUAL. Doc #: UA Part #: 07M1205P-A (CTS ME-V.35)

Enhanced Mini-Chansim Model VCS-232

TABLE OF CONTENTS TECHNICAL SPECIFICATIONS... Page 9

USER MANUAL. MODEL 2014 Interface Powered RS-530 to V.35 Converter. SALES OFFICE (301) TECHNICAL SUPPORT (301)

USER MANUAL. MODELS 1205 and 1205/34. Synchronous V.35 Modem Eliminators

RS-232/RS-422 Optical Isolator

USER MANUAL. MODEL 1225 ParaLink TM Parallel Short Range Modem. SALES OFFICE (301) TECHNICAL SUPPORT (301)

2DScan TM Barcode Scanner

Installation Guide. Wyse Rx0L Thin Client Flash and RAM Upgrade Option Kit. Issue: PN: L Rev. A

USER MANUAL. MODEL 1052 idsl Modem with RS-232 Interface. An ISO-9001 Certified Company SALES OFFICE (301) TECHNICAL SUPPORT (301)

Rack Input Module Installation Instructions

An ISO-9001 Certified Company

Infosystem Remote Touchscreen Installation Instructions

Start Here. Features. Model DS108 Dual Speed Hub Installation Giude

IE-MediaChassis/1. Operation Manual

T1 Fold (2KM) SEPTEMBER 1995 MT612A-ST MT612AE-ST. T1 - Fold CUSTOMER SUPPORT INFORMATION

USER MANUAL MODEL Bidirectional (IEEE-1284) Line Driver/Converter

1.0 Description. 2.0 Unpacking. 3.0 Installation

CHS 7Ci. Bluetooth Cordless Barcode Scanner. Quick Start Guide

User Guide CPSMP VAC Power Supply Module: PointSystem CPSMC Accessory CPSMC Accessory. Contents.

Monarch 9414 Printer. TC9414EM 7/99 Rev. AB 1999 Monarch Marking Systems, Inc. All rights reserved.

NANOPTIX HEAVY DUTY KIOSK REGULAR CUTTER PRINTER Thermal Print Mechanism Replacement

RS-232 HS4 JANUARY 1997 IC131C CUSTOMER SUPPORT INFORMATION

Optical DVI Daisy-chain Extender

NSD/M1 Installation Instructions

BEETLE /Fusion Compact. Installation Guide

Installer/User Guide

USER MANUAL. MODEL 2011 High Speed Asynchronous to Synchronous Converter

Connectivity Peripherals User s Guide. Point 510 Point 1600

FIBER OPTIC A/B/C/D SWITCH (LATCHING)

ADL-100 Operator s Manual

USER MANUAL. MODEL 552 Series. High Speed Telco Surge Protectors. SALES OFFICE (301) TECHNICAL SUPPORT (301)

Copyright Black Box Corporation. All rights reserved Park Drive Lawrence, PA Fax

International Headquarters

BACnet Router Start-up Guide

adynamo Technical Reference Manual PART NUMBER October 2014

Allworx Tx 92/24 Telephone Expander Installation Guide

FIBER OPTIC A/B/C/D SWITCH (NON-LATCHING)

USER MANUAL. MODEL 1003 and 1003S Asynchronous, 2-Wire, Carrier Sense Short Range Modem

NCH-1000 (Multiple Breaker Types) Installation Instructions

Quick Start Installation Guide

SCSI Fiber Optic Extender

Installation Guide for. PCC Premier Precision Camera Controller. Document Rev. C

AREA CODE CHANGE. Please note that the area code for Paradyne Corporation in Largo, Florida has changed from 813 to 727.

USB USB Data Transfer

Four Port RS-232 Serial Interface

Verify Package Contents

About the LAN Extenders Warranty Federal Communication Commission Radio Frequency Interference Statement Getting to Know the LAN Extenders The LEDs

McPC/Giga-MediaLinX. (PCI and Low Profile PCI Version) 10/100/1000 Mbps. Operation Manual

PC Media Converter, Switching (TP-TX/FX)

Broadband Automatic Disconnect Switch. User Manual

USER MANUAL MODEL 505M-CHC. Surge Protected DB-25 to RJ-45 Modular Adapter

USER MANUAL. MODEL 1018 High Speed Short Range Modem w/ Extra Controls SALES OFFICE (301) TECHNICAL SUPPORT (301)

USER MANUAL MODEL 2017P MODEL 2017P60. RS-232 to 20mA and. RS-232 to 60mA Current Loop Converters

Cat. No KT/B. Installation Data

Installation Guide AVA-2902E/I. PCI-to-Fast SCSI Host Adapters. PCI SCSI Host Adapter with Internal or External Connector

User s Guide CPSMC0200-2x0 Dual-Slot PointSystem Chassis

USER MANUAL MODELS 2156 & CopperLink Ethernet Extenders SALES OFFICE (301) TECHNICAL SUPPORT (301)

NETGEAR, Inc Great America Parkway Santa Clara, CA USA. April 2004

Express All-Fiber DVI. User s Manual (For M1-1000)

Model Bulk Sampling Scale. User s Manual

AT IEEE 802.3af Universal Multi-voltage PoE Splitter. Installation and User Guide. PN Rev A

Stacking Module. Installation Guide AT-MCF2000S. PN Rev A

BEETLE MSR Module. Swipe Card Reader. for BA7x. User Guide

INSTALLATION GUIDE ADAPTEC SCSI CARD 29320LP

INSTALLATION INSTRUCTIONS

BACnet Router Start-up Guide

CAUTION: Before installing the Windows or Macintosh operating system, see our knowledge base answer ID 1485 for precautionary procedures.

Giga-MiniMc TX & RX USER MANUAL

CrystalLink USB 2.0 CAT5 INSTALLATION AND OPERATIONS MANUAL. Part Number CLK-1U4TP-100M/PE Stancliff Road Phone: (281)

STATUS Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

DeviceMaster RTS 16-Port Hardware Installation

MCN Monitoring and Control Network Comparator Display System. Host Computer Interface Module HIB Hardware Reference Manual

CANADIAN D.O.C. WARNING

Keyboard Display Unit

3710 ACM 3750 PDC 3800 RTU. ISOCOM Communications Card Retrofit Instructions

Installation Job Aid for Ethernet Routing Switch 3600 Series

USER MANUAL MODEL KiloModem II AC Powered, High-Speed X.21 Short-Range Modem

iq 16 Sync Charge Box

USER MANUAL. TS Series (Model 52X) Terminal Strip Surge Protectors. SALES OFFICE (301) TECHNICAL SUPPORT (301)

PETROL (P-SERIES), TTL, INSERTION READER TECHNICAL REFERENCE MANUAL

Dual Port RS-232 Serial Interface

Giga-MiniMc TX/FX Giga-MiniMc TX/SFP. Operation Manual

USER MANUAL MODEL 515 DB-15 Surge Protector

User s Manual. Document # , Rev 1.0, 11/1/04

PortServer II. Hardware Installation Guide C

COBALT C INSTALLATION GUIDE RFID CONTROLLER ESCORT MEMORY SYSTEMS. High Frequency Passive Radio Frequency Identification Controller

TMS-3000 Controller. Release Notes, Version GTS V2.2.0, Year 2000 Enhancement GDC 036R , Issue 1, November General DataComm, Inc.

WILDCAT REALIZM 800 WILDCAT REALIZM 500 WILDCAT REALIZM 200 WILDCAT REALIZM 100

550 Watt Power Supply

Installation Job Aid for VSP 4850GTS

USER MANUAL. MODEL 1082 and 1082/144 idsl Modem with V.35 or X.21 Interface. An ISO-9001 Certified Company

USER MANUAL. Elo Touch Solutions USB Expansion Module

QS7800A Network Interface ControlBus Module for 7800 SERIES Relay Modules

Product Installation Guide. SST Ethernet Serial Provider (ESP) PN /D September 2000

MIL-S24002TGxx. 24-port 10/100/1000 TX 2 Combo SFP Slots Unmanaged Switch. User Guide

HMXAT200 Series System Controller

Reliable High-Performance 350 Watt ATX 12V Power Supply. ATXPOW350PRO Instruction Manual

Safety and Radio-Frequency Interference

YJ Carat and Gold Scales

Transcription:

Doc #: Part #: 07M-A MODEM ELIMINATOR, X.21 (CTS ME-X.21) INSTALLATI AND OPERATIS MANUAL An ISO-9001 Certified Company Copyright 2000 Patton Electronics Co., All Rights Reserved

PATT ELECTRICS CO. INSTALLATI AND OPERATIS MANUAL COPYRIGHT NOTICE Copyright 2000 Patton Electronics Co., All Rights Reserved. PROPRIETARY NOTICE The information contained herein is proprietary and confidential to Patton Electronics Co. Any reproduction or redistribution of this publication, in whole or in part, is expressly prohibited unless written authorization is given by Patton Electronics Co. WARRANTY NOTICE WARRANTIES: Patton Electronics Co. (hereafter referred to as Patton) warrants that its equipment is free from any defects in materials and workmanship. The warranty period shall be two years from the date of shipment of equipment. Patton s sole obligation under its warranty is limited to the repair or replacement of the defective equipment, provided it is returned to Patton, transportation prepaid, within a reasonable period. This warranty will not extend to equipment subjected to accident, misuse, alterations or repair not made by Patton or authorized by Patton in writing. PUBLICATI NOTICE This manual has been compiled and checked for accuracy. The information in this manual does not constitute a warranty of performance. Patton reserves the right to revise this publication and make changes from time to time in the content thereof. Patton assumes no liability for losses incurred as a result of out-of-date or incorrect information contained in this manual. i

PATT ELECTRICS CO. INSTALLATI AND OPERATIS MANUAL EMISSI REQUIREMENTS FCC CLASS A Warning: Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment. NOTE: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expence. CANADIAN EMISSIS This digital apparatus does not exceed the Class A limits for noise emmissions from a digital apparatus set out in the Radio Interference Regulations of the Canadian Department of Communications. Le present appareil numerique n emet pas de bruits redioelectriques depassant les limites applicables aux appareils numeriques de la Class A prescites dans le Reglement sur le brouillage redioelectrique edicte par le ministere des Communications du Canada. ii

PATT ELECTRICS CO. INSTALLATI AND OPERATIS MANUAL TABLE OF CTENTS CHAPTER 1 - OPERATI Clocking... 1-1 Delaying INDICATE... 1-1 Power... 1-1 Approvals... 1-2 Available Options... 1-2 CHAPTER 2 - SETUP AND INSTALLATI Power Connection... 2-1 Factory Configuration Switch Settings... 2-1 Disassembly... 2-2 Installation... 2-2 Equipment Grounding (JP4)... 2-2 IND Delay, Port 1 (SW2-1,2)... 2-2 IND Delay, Port 2 (SW2-4,5)... 2-2 Internal Baud Rate Selection (SW1-1,2,3,4)... 2-3 High Speed Option Rates (JP7,JP8,JP9,JP10)... 2-3 Factory Test Jumpers (JP1)... 2-4 APPENDIX DB-15 Connector Pins Used... A-1 Signal Flow Diagram... A-1 Strapping Guide... A-2 iii

PATT ELECTRICS CO. INSTALLATI AND OPERATIS MANUAL CHAPTER 1 - OPERATI The (CTS ME-X.21) is a cost effective solution for interconnection of X.21 terminal devices located in proximity of each other. The use of two modems is eliminated with a resulting cost savings to the user. The (CTS ME-X.21) complies with the CCITT V.11 balanced interface specification. Two 15 pin DB-15 connectors are provided to interface to the X.21 terminals. Clocking Clocking at rates up to 768Kbps with the low speed version and up to 2.048Mbps with High Speed Option are provided by the internal baud rate generator. The generator will provide clocks for both terminal and insure the data is synchronized with the S Clock in both directions. Delaying INDICATE Control (C) is looped back to Indicate (I) on each Port. To allow terminals requiring I delay to function properly, selectable delays of Constant, 0mS, 8mS and 50mS of C to I delay is provided. Each Port is individually configured for I delay. Power 110 or 220 Volt operation is provided by a convenient switch located on the rear panel of the (CTS ME-X.21). Simply install the proper fuses (110VAC -.16ASB, 250V or 220VAC -.8ASB, 250V) and power plug for the country of use and select the proper line voltage and the unit is ready for operation. INTERNATIAL SERIES PWR T R C I S 1-1 OPERATI

PATT ELECTRICS CO. INSTALLATI AND OPERATIS MANUAL Approvals Safety approvals for UL, CSA & TÜV have been granted allowing the Modem Eliminator to be used virtually anywhere in the world. FCC Part 15 class A emissions approvals insure the Modem Eliminator will not interfere with any of the other equipment in your data center. CE NOTICE: The CE symbol on your Patton Electronics equipment indicates that it is in compliance with the Electromagnetic Compatibility (EMC) directive and the Low Voltage Directive (LVD) of the Union European (EU). A Certificate of Compliance is available by contacting Technical Support. Available Options (CTS ME-X.21) is available in both stand-alone subset or rack-mountable versions (RC). Various configuration of the interface are also available from the factory. The RC fits into the Model 1010R16 16 Card Rack Assembly. OPERATI 1-2

PATT ELECTRICS CO. INSTALLATI AND OPERATIS MANUAL Caution, Disconnect the POWER Before Removing The Cover Vorsicht, Befor Deckung Abnehmen Mach Strom Zu. CHAPTER 2 - SETUP AND INSTALLATI Power Connection Before connecting the (CTS ME-X.21) to a AC power source the top cover must be installed and secured with the supplied #8-32 screws. The unit is supplied with a 110/220VA voltage switch, turn the switch with a coin or screw driver to the appropriate voltage for your country. EXAMPLE: In the United States of America; set to 110VA. The unit is supplied with a IEC power connector next to the voltage select switch, plug the power cord into the connector until it is firmly seated. You may now connect the power cord into your AC outlet. Factory Configuration Switch Settings The (CTS ME-X.21) is configured prior to shipment with the switches set to the following default positions: Switch 1-2, 3, 5 and 6 to, 1 and 4 to. Baud Rate = 64Kbps Switch 2-1, 3, 4 and 6 to, 2, and 5 to. Port 1 IND Delay = 0 Port 2 IND Delay = 0 JP1 - JP3 always connected JP4 - Open HS Option JP7 - Open JP8 - Open JP9 - Open JP10 - Open 110 / 220VA Switch Fuse Drawer CAUTI : FOR CTINUED PROTECTI AGAINST RISK FIRE, REPLACE LY WITH SAME TYPE AND RATING FUSE. PORT 1 IEC Power Connector If the system application requires one of more of the default settings to be changed, it will be necessary to remove the top cover of the enclosure to access and change the DIP switches or Jumpers located on the printed circuit board. 220 110 100-120V 0.16ASB,250V TO.16A,250V 200-240V 0.08ASB,250V TO 0.08A,250V * * Switch fuse for 100-120V (.16ASB, 250V) or 200-240V (.8ASB, 250V) as noted on rear of unit. 2-1 SETUP & INSTALLATI

PATT ELECTRICS CO. INSTALLATI AND OPERATIS MANUAL Disassembly Remove the top cover by unscrewing the phillips head screws located on the left and right sides of the (CTS ME-X.21). The configuration switches and Jumpers are located on the PCB as indicated on the strapping guide in the Appendix of this manual. After the switch selection activity is completed, re-install the top cover BEFORE connecting to an AC power source. Installation Select an appropriate location accessible to and within six feet of an AC power outlet. The outlet must have a ground pin receptacle for product warranty. "Straight Through" shielded cables, terminated in male X.21 (DB-15) connectors should be used to connect the two terminals to the (CTS ME-X.21). Set the switches and Jumpers to match the required configuration using the descriptions in this chapter and the strapping guide in the appendix. Equipment Grounding (JP4) JP4 provides for grounding interconnection in those systems requiring a connection between (Frame Ground) and (Signal Ground). Connect LY if required. IND Delay, Port 1 (SW2-1,2) SW2 position 1 and 2 selects C to I delay for the terminal connected to PORT 1. C (pins 3,10) from PORT 1 is looped back to I (pins 5,12) through the delay circuitry. IND Delay, Port 2 (SW2-4,5) SW2-1 SW2-2 DELAY Const 0mS 8mS 50mS SW2 position 4 and 5 selects C to I delay for the terminal connected to PORT 2. C (pins 3,10) from PORT 2 is looped back to I (pins 5,12) through the delay circuitry. SW2-4 SW2-5 DELAY Const 0mS 8mS 50mS Internal Baud Rate Selection (SW1-1,2,3,4) SETUP & INSTALLATI 2-2

PATT ELECTRICS CO. INSTALLATI AND OPERATIS MANUAL Selection of internal rates is provided by configuration of SW1 positions 1 through 4 and JP7 through JP10 if the High Speed Option has been installed by the factory. The following table shows the rates available: SW1-1 SW1-2 SW1-3 SW1-4 RATE HS Opt 768K 384K 192K 128K 72K 64K* 57.6K 56K 48K 38.4K 28.8K 19.2K 14.4K 9.6K 4.8K High Speed Option Rates (JP7,JP8,JP9,JP10) If the high speed option is installed the following rates can be utilized by setting SW1 positions 1 through 4 to : JP10 Installed JP7, JP8 & JP9 Removed - 256K JP9 Installed JP7, JP8 & JP10 Removed - 512K JP8 Installed JP7, JP9 & JP10 Removed - 1.024M JP7 Installed JP8, JP9 & JP10 Removed - 2.048M Factory Test Jumper (JP1) 2-3 SETUP & INSTALLATI

PATT ELECTRICS CO. INSTALLATI AND OPERATIS MANUAL The factory test jumper must be installed for the Modem eliminator to properly function. Insure this jumper is installed prior to operation of the unit. SETUP & INSTALLATI 2-4

PATT ELECTRICS CO. INSTALLATI AND OPERATIS MANUAL APPENDIX Technical Specifications Application Interconnect two X.21 terminal type devices Capacity Two X.21 Sync or Async Terminals Data Format Data is Transparent Port 1 Data Rates 4.8K, 9.6K, 14.4K, 19.2K, 28.8K, 38.4K. 48K, 56K, 57.6K, 64K, 72K, 128K, 192K, 384K & 768Kbps (256K, 512K, 1024K & 2048K with High Speed Option) Timing Internal Baud Rate Generator Front Panel Indicators:... Power, T, R, C, Port 2 1 - Frame Gnd Frame Gnd - 1 8 - Signal Gnd Signal Gnd - 8 (3,10) - Control (5,12) - Indicate Control - (3,10) Indicate - (5,12) (2,9) - Trans Trans - (2,9) I, S Channel Interface Two CCITT X.21(V.11) female connectors (DB-15) Power Source 100-120/200-240VAC, 50 to 60Hz, 0.16/0.08A switchable Environmental Oper Temp:... 32 to 122 F (0 to 50 C) Rel Humidity:.. 5 to 90% noncondensing Altitude:... 0 to 10,000 feet Dimensions Height:... 1.75 inches (4.44 cm) Width:... 8.90 inches (22.60 cm) Length:... 10.00 inches (25.40 cm) (4,11) - Receive Receive - (4,11) CLOCK GENERATOR (6,13) - Sig Timing Sig Timing - (6,13) Signal Flow Diagram Transm it(b )(from DTE) Control(B ) (from DTE) Receive(B ) (from DCE) Indication(B ) (from DCE) SignalTim ing(b )(from DCE) 9 10 11 12 13 14 15 1 2 3 4 5 6 7 8 Shield (com m on) Transm it(a ) (from DTE) Control(A ) (from DTE) Receive(A ) (from DCE) Indication(A ) (from DCE) S ignaltim ing(a ) (from DCE) GND (com m on) DB-15 Connector Pins Used A-1 APPENDIX

INSTALLATI AND OPERATIS MANUAL PATT ELECTRICS, INC. SW1 SW2 Power T R C I S 1 2 3 4 JP1 A-2 APPENDIX 5 6 1 2 Baud Rate Select Not Used Not Used Install Only One Jumper to Select the Required Rate LY THE OPTIAL HS VERSI 256Kbps HS Option 512Kbps HS Option Ch1 IND Delay Select 1.024Mbps HS Option 2.048Mbps HS Option JP10 JP9 JP8 JP7 Ch 1 IND Delay SW2 1 2. Delay Constant 0 ms 8 ms 50mS Ch 2 IND Delay SW2 4 5. Delay Constant 0 ms 8 ms 50mS Baud Rate Select SW1 1 2 3 4 Speed HS Option 768K 384K 192K 128K 72K 64K 57.6K 56K 48K 38.4K 28.8K 19.2K 14.4K 9.6K 4.8K CGND TO DGND JP4 Chan 1 Chan 2 3 Not Used 4 5 6 Ch2 IND Delay Select Not Used Factory Test Strap Must be Installed For Proper Operation