Feedback Module Are Feedback Modules needed? All functions in one module!

Similar documents
Feedback Module Are Feedback Modules needed? All functions in one module!

Power 7 The universal booster for almost all digital systems

6021 Infrared & LocoNet Adapter For connecting LocoNet devices to the Control-Unit

The Success Story Continues!

The Digital Center for PC. Manual

Working model decoder

Electronics for the intelligent railway

Multi-protocol decoder with Load regulation for DC and Faulhaber motors

Manual for Software Version 1.0. The shortest connection between technology and pleasure

On the Wire without Wire. Manual Assembly and Basic Operation

Features. Description. Multi-protocol decoder with load regulation for DC and Faulhaber motors

For the Intelligent Railway New Items 2008

SRC8 Switch & Route Controller

Power 3/6. Multi-Protocol Power System Booster by Uhlenbrock. Manual

TEAM DIGITAL. BlocD8 High Density Block Detector. BlocD8

TEAM DIGITAL. SRC16 Switch & Route Controller

TEAM DIGITAL. SRC162e Switch & Route Controller

Unleashing the Power of DCC

TEAM DIGITAL. CSCe Central Signal Controller

MasterControl. Central unit for digital control EasyControl. Manual. Art.-Nr

TEAM DIGITAL. DCCBreak DCC Circuit Breaker

NEWSLETTER VOLUME 20 - NO. 6 November- December 2008 Dr. Tom Catherall, Editor

SniffControl. Adapter for connecting digital central units to the digital control EasyControl. Manual. Item no

TEAM DIGITAL. SMD84 Switch Machine Driver with Serial Bus

XPA XpressNET Phone Adaptor

HandControl. Decentralised control device for digital control EasyControl. Manual. Art.-Nr

Z21 digital control system

DS64. All Scales Track Voltage Up to 22 Volts

Mini Panel. Accy and Macro Controller. Build the kind of control panels you ve always wanted without complicated wiring!

BDL16 LocoNet Occupancy Detector with RX4 Installation Information Manual

Using Digitrax Devices on a Non Digitrax DCC Controlled Layout Rev. 3 By Elmer McKay < >

Hatton s DCC Decoder Instructions

Version Falkner Software, Schwabach

Unleashing the Power of DCC

Complete Train Control. Run Your Trains, Not Your Track! 1 PR3 Programmer 1 USB Cable 1 This Instruction sheet

SBS Software. Signals By Spreadsheet. Figure 1, SBS System Configuration

The PSX-1, 2, 3, 4 Series

Lenz Digital Plus DCC

Unleashing the Power of DCC

User Manual. LokPilot V2.0 LokPilotDCC V2.0 LokPilot micro. 4th edition, August 2005

The PSX-AR Series. New Exclusive Digitrax Configuration New Timing Delay Features New Programmable Power Up Status New Auto Stop For DCC Use Only

switch machines when the polarity is reversed. Switch machine can also be controlled with standard DCC Accessory Commands or push buttons.

LH100 Dispatcher s Throttle 1. Designed for use on all XpressNet systems

BOD2 & BOD4 Module User Manual - version

REVOLUTION DCC SYSTEM INSTALLATION AND OPERATION MANUAL

Lenz Digital Plus DCC

DCC. Versions Available: PSX-1 One Output, PSX-2 Two Outputs, PSX-3 Three Outputs, PSX-4 Four Outputs:

Information LR100 Feedback Encoder

LOCOMOTIVE DECODER DHP160 DHP250 DHP260

Attention: The connectors on the BMD16N are not normal network plugs. Never connect the decoder to a PC or any other network device!

Reference Manual. Commander. Commander Reference Manual. Operation Content. Editors. App. Index. Version 1.2

Designed for use on all XpressNET systems

PM4 INSTRUCTIONS. PM4 WIRING (See Tables 1 & 2 and Wiring Examples)

POWERHOUSE. -- the finest in Digital Command Control -- PRODUCT MANUAL FOR PB-205a DUAL 5AMP POWER STATION

POWERHOUSE. -- the finest in Digital Command Control -- PRODUCT MANUAL FOR PB-110A TEN AMP POWER STATION

PIKO SmartControl the digital future of model train control!

LNCP LocoNet Control Point

TM Accessory decoder. Magnetartikel- und Schaltdecoder. User's manual. Handbuch

Complete Train Control. Run Your Trains, Not Your Track!

DR5000 DIGICENTRAL. instruction manual. Firmware ab V1.5.1 ( ) DR5000 DIGICENTRAL

RCA-1. RailCom Anzeige. RailCom display device. Afficheur RailCom. Anleitung. RailCom-display. Manual. Mode d emploi. Handleiding

PR3 Help. Copyright <2008> <Digitrax Inc.>

The PSX-AR Series (Rev:G,4/10/09)

The DB3a provides 5 Amps of additional power to an SB3a Smart Booster or other 5 Amp DCC system to run trains and accessories.

ESU Navigator. Instruction manual. DCC version First edition, March 2010 ESU P/N

Complete Train Control. Run Your Trains, Not Your Track! 1 PR3 Xtra Programmer 1 USB Cable 1 PS14 Power Supply 1 Instruction Sheet

DCS-E 1kW Series, DLM-E 3kW & 4kW Power Supplies

tom Programmer User Manual - Software version

Switch-It Accessory Decoder

Signals by Spreadsheet

User Manual - English

INSTRUCTION MANUAL. The ZIMO COMMAND STATION MX10

WARNING NOT ZTC Controls Ltd

User Manual - English

The Az S 350 U microcomputer axle counting system. Vacancy and occupancy detection of track sections.

ECN module MGC-PRO MicroDrive

PLEASE READ INSTRUCTIONS CAREFULLY BEFORE INSTALLATION!

StEin - INSTRUCTION MANUAL

MODEL NC105 DIGITAL CODED SQUELCH ENCODER/DECODER INSTRUCTION MANUAL

DCC Basics and Beyond. Lee Dobyns 4/25/2015

RESISTRON. Replacing RES-225/RES-445. Replacement Instructions. Comparison of RES-225 / RES-445. Dimensions. Set point selection

BNI EIP Z016. IP67 Modules, 8 Outputs BNI EIP Z016 BNI EIP Z016 IP67 Modules, 16 Outputs User s Guide

Digitrax Complete Train Control Starter Set Manual

DTM30 Digital Tower Master. User Manual

GEM DIGITAL POINT ACTUATOR

Handbook GBM in Action

Ethernet/SIOX Gateway Applicable to firmware ver 1.0

Your train track command control station.

CKT-TIMELOCK v1 User Manual

Tip: - m83 Special Advanced Functions Controlled With TrainController Date: Link ,

Manual GBM-1. Item no tams elektronik. 4-fold Track Busy Indicator

PTC Model III. Programmable Turntable Controller. Automatic Power Router. Installation Instructions

The ACE is the result of over two years development work. We asked ourselves a simple, but challenging, question.

JUMO dtrans T02. programmable. transmitter. B Operating Instructions 5.00/

NMRA 2018 Kansas City Signaling with LCC (Layout Command & Control)

Operating Manual. DMX Relay Card 3002R

LI101F Hi-Speed XpressNet Computer Interface

OPERATING MANUAL. The ZIMO COMMAND STATION MX10

Operating instructions. Relay adapter, analog ALMEMO ZA 8006-RTA4 V

MegaPoints Controllers Feedback Module.

Transcription:

Feedback Module 63 320 for 2-rail Track The new dimension in digital feedback Are Feedback Modules needed? On a model railway feedback modules give you information about whether a track is occupied or not. That is very useful for a shade station, for example, because in most cases it is out of sight. Feedback modules are essential if the model railway is to be automated or controlled with a computer program. The automatic or the program needs the information from feedback modules to decide whether a train is permitted to enter a certain track or which route is to be activated. All functions in one module! The feedback module 63320 for 2-rail track provides all functions for digital feedback in a single module: track occupation detection (for 8 track sections), feedback to the center and power monitoring. The track occupation detector checks whether there is a power load in its track section. That can be a locomotive, a lit wagon or a wagon whose axle was bridged with resistance lacquer (Part No. 40410). If a current of at least 1mA flows in the monitored track section, the section is reported as occupied ; if no current flows then the section is vacant.

The feedback queries the state of the track occupation detector unit. It reliably and quickly passes on the information about the track state to the attached devices or to computer control programs via LocoNet. The voltage monitor prevents an incorrect vacant message from being sent even when switched off. A track is only reported as vacant when the operating voltage is present on the track. Since, when the power is switched off no current can flow, each track would otherwise report as vacant. The Feedback module can be used in conjunction with the Intellibox or the DAISY system from Uhlenbrock, with the TwinCenter from Fleischmann or with other centers with a LocoNet connection. The feedback information is displayed directly by Intellibox and TwinCenter or passed on to a computer via the integrated interface. In addition, the feedback information can be used to activate routes that are stored in an IB-Switch (Uhlenbrock 65800). Thus an automatic train control which is influenced by the trains can be setup. In order to make the feedback module useful in more varied applications, the unit can switch two freely programmable solenoid addresses for every state change vacant or occupied for each track input magnet. Thus a St Andrews cross at a railroad overpass can be switched directly from the feedback module without a route call to another device. The module is supplied with power from the LocoNet. The maximum current load in a monitored track section is to 3A. The modules are preset in the factory so that the track contacts, which are connected to inputs contact 1 to contact 8, have feedback addresses 1 to 16. Programming of the module can take place while operating since the Intellibox uses its own menu for this. 2

Connection Connect the feedback module, using the enclosed LocoNet cable to the Intellibox or TwinCenter or the LocoNet socket of a DAISY system LocoNet T or LocoNet B output. Connect the digital power (red) to the terminal labeled Digitalspannung on the module. 3

Isolate the track sections which are to be monitored on one side from the remainder of the model railway layout. In each case connect an isolated section with one of the inputs track 1 to track 8. Important: Insert the isolation barriers into the side of the track, which is connected with the digital power (red). Booster Operation If the feedback module is used in an area of the model railway layout that is supplied by its own booster you must take care to connect the booster ground (pin 4, brown) to the ground pin (pin 4, brown) of the Intellibox (TwinCenter, DAISY/Power 2) in order to have trouble free operation. Programming So that the individual feedback data can be used in a digital system individual addresses must be assigned to the monitored sections. There are two ways to achieve this: With simple programming any address is assigned to the monitoring input for track 1. The fifteen other inputs automatically receive the subsequent addresses. Further settings cannot be made. With the Intellibox starting with software version 1.3 the programming of the module s individual LocoNet CVs is possible. Any desired address can be assigned to each module and each monitoring input. In addition all parameters of the feedback module can be individually changed. Simple Programming Press the programming key on the module. The control LED beside the key will blink. 4

On the controller (Intellibox, TwinCenter, DAISY or another LocoNet center) or an accessory device (IB-Control, IB-Switch, DAISY controller) press the switch, that has the address value that is to be assigned to the monitoring input Kontakt 1. If for example the contacts connected to this module are to be addressed with the addresses 9-16 you switch the turnout with the address 9. Press the red or green key of the turnout. After the turnout is switched once, the module s control LED turns off and the contact at input KontaKt 1 is assigned the feedback address, which corresponds to the turnout address. Monitoring inputs Kontakt 2-15 are automatically given the following 7 addresses. Remember that if you programmed a module to address 9 that addresses 10-16 were also assigned. This results in a maximum input value of 2041 (2048 possible addresses minus 7). For smooth operation it is necessary to avoid duplicates. Important: When programming with the programming key all programmed parameter settings made with Intellibox are put back to their factory setting! Configuring a LocoNet Module LocoNet devices are configured by LocoNet Configuration variables (LNCVs). These LNCVs can be programmed with the help of the Intellibox (starting from software version 1.3), the IB-control (starting from version 1.55), the TwinCenter (starting from version 1.1), with Intellibox Basic or the Intellibox II. 5

Calling up a LocoNet Module With Intellibox, Intellibox IR, Intellibox Basic, IB-Control and TwinCenter: Connect the module to the LocoNet. Press to the [menu]-key followed by the [mode]-key on the Intellibox (starting from software version 1.3) to take you to the Basic Settings menu. Scroll with the [ ]-key up to menu option LocoNet Prog.. Press the [ ]-key: Enter the part number of the module and press the [ ]-key. Give the address of the module (with a new module that is the 1) and press the [ ]-key. The upper line shows the module part number and the valid module address. The lower line shows the LocoNet CV id number (here 0 for the module address) and the current value (here 1). 6

With the Intellibox II Connect the module to the LocoNet. Press the [mode]-key and select the LocoNet programming mode on the left side. In the menu which appears, enter the module part number and the module address (with a new module that is the 1). Press the Prog.Mode key. The module is put into the programming mode and the value of the LNCV0 (module address) is displayed. Important: Each module requires a module address for programming so the digital center knows which module is meant. The factory setting of a module is address 1. If other similar modules are connected to a center they must receive other module addresses. The allowable address range is 1 to 65534. To confirm the module is addressed correctly, it blinks a red LED, while the module is in programming mode. Reading and Programming a LocoNet Module Similarly to DCC Locomotive decoders, the behavior of the module is determined by different configuration variables (CV). Contrary to Locomotive decoders these are not programmed via the track, but via the LocoNet and are therefore referred to as LocoNet CVs or LNCVs. With Intellibox, Intellibox IR, Intellibox Basic, IB-Control and TwinCenter: After the module is called (see chapter 3.1) the Intellibox display shows: The cursor blinks under the 0. 7

At the cursor position enter the Id number of the LocoNet CV you would like to program and press [ ]-key. The Intellibox reads the LNCV. The value is shown at right of the lower line of the display. Move the cursor to the right with [ ]-key and enter desired value for this LNCV using the numeric keys. By pressing [ ]-key the changed value is programmed. Press the [ ]-key back to select another LNCV. Press the [ ]-key back to select another module. Or leave programming with the [menu]-key. Tip: As usual with Intellibox, numerical values indicated by the blinking cursor can be incremented or decremented by pressing the [+] or [ ] respectively. With the Intellibox II Enter the Id Number of the LNCV to be programmed via the LNCV. Press the menu key LNCV read. The Intellibox reads the LNCV and the value of the LNCV appears Value. Press the Value menu key and change the LNCV value. Press the LNCV program menu key to save the value of the LNCV in the module. Change other values in the manner described. To terminate LocoNet programming firstly press the menu key Prog.mode off and then the menu key Back. 8

The Universal Address 65535 With the universal address, as the name implies, all LocoNet displays can be called up. Since the universal address is not a real address, with which different LocoNet displays can be identified, it can only be used in order to call up displays, whose individual address is unknown. Therefore, only the appropriate display may be connected to the LocoNet. If the display is then called, the programmed address can be read from LNCV 0. Reset Using Simple Programming with the programming key all parameter setting which are made with Intellibox programming can be put back to their factory setting! 9

Description of individual LocoNet CVs The module is programmed with LocoNet Configurations variables. These LNCVs are addressed with an Id number and can then be set to a certain value. With feedback module 63320 the following LNCVs can be programmed: LNCV 0 The Module Address Each module must have a module address for programming so that the center knows which module is meant. The allowable address range is 0-2047. LNCV 1-8 Addresses of the Feedback inputs Each monitoring input is assigned freely selectable feedback. Intellibox and TwinCenter can administer feedback addresses within the address range 1-2048. That corresponds to 256 modules with 8 addresses each. LNCV 17 Report Address With the help of this solenoid address, the module can be commanded to send the state of the connected tracks at any time in order to update a computer program. For example: if the turnout with the Report address is switched on the layout, the feedback module sends the state of all its monitored track sections to the LocoNet. LNCV 20 Module Configuration BIT 0 = 0 Value 0 (Factory Setting) The addresses for the individual monitoring inputs are assigned automatically. i.e. the module takes the address for input Kontakt 1 from LocoNet CV 1 and adds for the following inputs values 1 to 7. Track 1 = Address from LNCV 1 10

Track 2 = Address from LNCV 1 + 1 Track 3 = Address from LNCV 1 + 2 Track 4 = Address from LNCV 1 + 3 Track 5 = Address from LNCV 1 + 4 Track 6 = Address from LNCV 1 + 5 Track 7 = Address from LNCV 1 + 6 Track 8 = Address from LNCV 1 + 7 BIT 0 = 1 Wert 1 The module uses the addresses that were programmed in LocoNet CVs 1-8. Track 1 = Address from LNCV 1 Track 2 = Address from LNCV 2 Track 3 = Address from LNCV 3 Track 4 = Address from LNCV 4 Track 5 = Address from LNCV 5 Track 6 = Address from LNCV 6 Track 7 = Address from LNCV 7 Track 8 = Address from LNCV 8 BIT 1 = 0 Value 0 (Factory setting) The delay values for the occupied and free message, which were programmed into LocoNet CVs 21 and 41, apply to all inputs of the module. BIT 1 = 1 Value 2 Individual: the delay values for occupied and free message are used for each input, as they were programmed into LocoNet CVs 21-36 and 41-56. BIT 2 = 0 Value 0 (Factory setting) When the power to the LocoNet module is switched on it does not send information. 11

BIT 2 = 1 Value 4 When the power to the LocoNet module is switched on the module sends the state of all monitoring inputs to the center. Important: You determine the input value for the LNCV 20 by first selecting the configuration that you would like this module to have. Then add the appropriate values and program the result into LNCV. The factory setting serves as an example: Automatic assignment of the feedback addresses according to LNCV 1 (value 0) Delay values for all inputs according to LNCV 21 and LNCV 41 (value 0) No sending of information when switching on the power (value on 0) The sum of the values and thus the entry for LNCV 20 is 0. LNCV 21-48 Switch On and Off delay The delay time determines how long a track section must be occupied or vacant before the appropriate message is sent by the module to the LocoNet. It can be programmed separately for occupied or vacant messages in a range from 0.01 seconds (10 ms) up to 2.55 seconds (2550 ms) in steps of 10ms. The valid range of values is 1-255. Factory setting is 3 (0.03 seconds) for the occupied message and 30 (0.3 seconds) for the vacant message. This is how you can calculate the value: Delay in Seconds x 100 = Value for the LNCV Value for the LNCV / 100 = Delay in Seconds LNCV 61-124 Solenoid Command for each track input If a track input changes from state vacant to the occupied state, the feedback module can send two individual solenoid instructions per track input. Likewise 12

individual solenoid instructions can be sent, if a track input changes from the occupied to the vacant state. The individual instructions are contained in the following LNCVs: 1. Solenoid command for State occupied for track 1-16: LNCV 61 to 76 2. Solenoid command for State occupied for track 1-16: LNCV 77 to 92 1. Solenoid command for State vacant for track 1-16: LNCV 93 to 108 2. Solenoid command for State vacant for track 1-16: LNCV 109 to 124 The values for the LNCVs 61 to 124 are calculated as follows: Switch solenoid to red : LNCV Value = Solenoid address * 10 Switch solenoid to green : LNCV Value = Solenoid address * 10 + 1 Example 1 The solenoid 21 is to be switched to red if the track connected to input 7 becomes vacant. LNCV 99 = 210, LNCV 115 = 0 Example 2 The solenoid 112 is to be switched to green and the solenoid 212 to red, if the track connection 4 is occupied. LNCV 64 = 1121, LNCV 80 = 2120 13

Table of individual LNCVs of the Feedback Module 63 320 LocoNet-CV Description Value Range Default Value 0 Module address 1-65535 1 (track 1) 1-8 Feedback address input contact 1-8 1-2048 1017 17 Report address 1-2048 varies 18 Software version - 2 19 Startup Time in 0.5 second steps 0-255 1 (track 1) 20 Module Configuration Bit 0 = 0 Bit 0 = 1 Bit 1 = 0 Bit 1 = 1 Bit 2 = 0 Bit 2 = 1 Automatic assignment of feedback addresses per LNCV 1 Individual feedback address per LNCV 1-8 Delay values for all inputs per LNCV 21 and LNCV 41 Delay values for each individual input per LNCV 21-28 and LNCV 41-48 The module does not send information via the LocoNet when power is switched on The module sends the state of all monitored tracks to the center when power is switched on 21-28 Delay for "Occupied" report Contact Track 1-8 0-255 3 (track 1) 41-48 Delay for "Vacant" report Contact Track 1-8 0-255 30 (track 1) 61-68 1. Solenoid command for contact track 1-8 when 0-20481 0 occupied 77-84 2. Solenoid command for contact track 1-8 when 0-20481 0 occupied 93-100 1. Solenoid command for contact track 1-8 when 0-20481 0 vacant 109-116 2. Solenoid command for contact track 1-8 when 0-20481 vacant 0 0 1 0 2 0 4 0 14

15

02045 If you have any questions call us. Hotline times are: 8583-27 Mon - Tue - Thu - Fri, 14:00-16:00 and Wednesdays 16:00-18:00 Our products are covered by a two year warranty. If it is defective send decoder along with the receipt of purchase to the following address: Uhlenbrock Elektronik GmbH * Mercatorstr. 6 * 46244 Bottrop Tel: 02045-8583-0 * Fax: 02045-8684-0 * www.uhlenbrock.de 16